tj-spring isolator

advertisement
L
Notes:
A
Dimensions in inches.
B
Protection for Medium and High
speed equipment.
W
Telescoping Housing Ductile Iron.
C
D
Choice of 3 attaching configurations.
See
Attaching
1/4" Ribbed Neoprene Pad
FREE HEIGHT-SEE BELOW
Typical Operating 5-1/2 to 6 Height
min. 5, max. 6-1/2
ATTACHING
T
P/N
A
B
C
D
L
W
TJB
538
4 7 16
9
16
1
2 -UNC
65 8
2
TJC
12
7
5
8
5 -UNC
8
13
2 38
TJE
12
7
11
16
5 -UNC
8
13
4 58
TYPICAL CALLOUT
External Load Transfer
Bolted Attaching
Type
Attaching
TJB 244 T
Max. Load
5 34
Most commonly used. " t " must be
approximately 4 inches or greater.
U
Internal Load Transfer
Gravity Attaching
TYPE
Max. Load
(lbs.)
Felt Pad
Usually used under concrete blocks
or flat bottomed equipment.
V
Max.
Defl.
(Inches)
Spring
Rate
(lbs/in)
Spring
Max.
TYPE
Max. Load
Rate
Defl.
(lbs.)
(Inches) (lbs/in)
TYPE
Max. Load
(lbs.)
1.13
1.13
1.13
1.13
2.30
2.20
1.13
1.13
1.13
1.80
1.50
1.30
1.00
.78
.78
18
49
70
94
52
70
165
216
281
220
341
550
1060
1950
2515
TJC
42
TJE
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
TJC
110
158
212
240
310
374
488
636
790
1022
1430
2120
3040
3920
TJB
6 12
Internal Load Transfer
Stud Attaching
v
6 12
Used when clearance over hole is
as little as 2 inches. Allows preset
to speed installation.
*
*
*
4 SPRINGS
2 SPRING
1 SPRING
21
TJB 55
TJB 79
TJB 106
TJB 120
TJB 155
TJB 187
TJB 244
TJB 318
TJB 395
TJB 511
TJB 715
TJB 1060
TJB 1520
TJB 1960
JOB:
*
*
*
1.13
1.13
1.13
1.13
2.30
2.20
1.13
1.13
1.13
1.80
1.50
1.30
1.00
.78
.78
Dwg. No.
F335
CUSTOMER:
36
98
140
188
104
140
330
432
562
440
682
1100
1120
3900
5030
*
*
*
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
TJE
Date
Revised
02/07/14
PREP By:
Date
CHKD By:
Date
84
220
316
424
480
620
748
976
1272
1580
2044
2860
4240
6080
7840
Max.
Spring
Defl.
Rate
(Inches) (lbs/in)
1.13
1.13
1.13
1.13
2.30
2.20
1.13
1.13
1.13
1.80
1.50
1.30
1.00
.78
.78
72
196
280
376
208
282
662
864
1124
880
1364
2200
4240
7800
10060
TYPE
TJ
CALIFORNIA DYNAMICS CORPORATION
5572 ALHAMBRA AVE. LOS ANGELES CA, 90032
PH 323-223-3882
FAX 323-223-7941
email: caldyn@earthlink.net
"CALL US - TO SET THINGS RIGHT"
Assoc. Member
TAG:
DO NOT SCALE DRAWING
SPRING ISOLATOR
SHATTER PROOF
DUCTILE IRON
Download