SprinklerMatic is an independently owned, state licensed, bonded and insured Fire Sprinkler and Fire Alarm contractor. In business for over twenty five years, our team has brought 150 years of combined executive, estimating and design experience throughout South Florida, making us uniquely qualified to tackle the largest and most complex projects. Since 1987, we’ve been designing, fabricating, installing, and servicing fire protection systems in commercial and residential buildings of all sizes, from condos to schools, hospitals, hotels, universities, warehouses and even airplane hangars. Whether you need annual, semi-annual, quarterly or monthly testing, we provide inspections, testing, and maintenance of your existing fire sprinkler and fire alarm systems to ensure you’re in compliance with NFPA 25 and 72 standards. Palm Beach Collier Monroe Broward MiamiDade ONE CALL REALLY DOES DO IT ALL: WE’RE A FULL SERVICE FIRE SPRINKLER AND FIRE ALARM COMPANY. OUR SERVICES INCLUDE: Fire Alarm Systems…..We Are a Notifier Distributor and Installing Contractor NRTL Fire Alarm Monitoring and Runner Service Portable Extinguishers, New, Recertification, Recharge and Hydo Testing Fire Pumps, Jockey Pumps and Controllers Standpipe Systems, Fire Hose Valves, Pressure Regulating and Pressure Relief Valves Holding Tanks, Atmospheric Valve and Recirculating Pumps Underground Fire Lines and Private Fire Service Mains Backflow Preventers, Post Indicator Valves, and Fire Department Connections Special Hazard Systems, Gas Systems, Foam Systems and Water Mist Signs, Escutcheions, Exit Lights, and Batteries And of Course, Fire Sprinkler Systems OUR BONDING COMPANY: Liberty Mutual Insurance Company has an A.M. Best rating of A XV. OUR INSURANCE COMPANY: Frank H. Furman Insurance has written our insurance for over a decade. We maintain the highest insurance and bonding limits in the industry, so you can rest easy knowing you’re dealing with a stable, secure company that will be here both today and tomorrow. BONDING ABILITY FINANCIAL RESPONSIBILITY Liberty Mutual A+15 Rated $7.5 Million Single Project Limit $20 Million Combined Limit 1% Blended Bond Rate $500,000 Secured Line of Credit (Untouched) Established Accounts and Discounts for Early Pay to Vendors INSURANCE CERTIFICATES Excess Umbrella $5 Million General Liability $1 Million Automobile $1 Million Professional Liability $1 Million Workers Comp $500,000 UMBRELLA $5,000,000 AUTO GENERAL LIABILITY WORKERS COMPENSATION $1,000,000 $2,000,000 Per Project Aggregate $1,000,000 - Occurrence *Includes Error & Omissions EMPLOYERS LIABILITY $500,000/$500,000/$500,000 QUALITY ASSURANCE Our mechanics and technicians are professional, courteous and passionate about fire protection. We believe in a hands-on approach and a get it done attitude to bring you the results you need. Our extensive training programs through NICET and the ABC apprenticeship assure that all local, state and NFPA standards are met. INSPECTION, TESTING AND MAINTENANCE As a property owner, it’s your responsibility to maintain your existing fire protection systems. When you consider the value of lives and property, incorporating a preventative maintenance program into your management plan only makes sense. Our NICET-certified and state registered inspection team has over 300 years of combined experience and will keep your fire sprinkler and fire alarm systems operating reliably, ensuring compliance with NFPA 25 and NFPA 72. 3-D DESIGN TEAM Sprinklermatic specializes in 3-Dimensional fire protection design. With over twenty five years in business we have the EXPERIENCE you need, and can provide COORDINATION documents for your next project. We eliminate waste through collaborative design between the engineer, owner and architect. Our design team uses the latest technology in 3-D modeling and clash detection software to create BIM, signed and sealed submittals, fabrication and installation drawings for fire alarms and fire sprinkler systems. Our proficiency in Revitt, Navis, MEP-CAD and ALARM-CAD and thorough knowledge of the Florida Building Code and Florida Fire Prevention Code saves you time and money through innovative concepts and designs. WHY BIM? A picture says a thousand words, and so does 3-D design, maximizing the visualization process prior to building will save you time and money. Overlay the MEP (Mechanical, Electrical and Plumbing) Identify Conflicts Before They Occur Minimize Change Orders Prefabricate Material Please visit our website and YouTube channel for examples of our work. www.Sprinklermatic.net MIC Microbiologically Influence Corrosion is an electrochemical reaction of the internal surface of the pipe, water and trapped air inside the sprinkler system. This type of corrosion can affect the performance of your sprinkler system; which is why NFPA 25 requires an inspection for pits, nodes and tubes in your piping every five years. Our team is up to speed with the latest protocols, technology, products, testing procedures and can provide permanent feed chemical injection systems to help mitigate MIC corrosion. FLORIDA ADMINISTRATIVE CODE 61G15-32.004 Design of Water Based Fire Protection Systems. (h) Microbial Induced Corrosion (MIC). The Engineer of Record shall make reasonable efforts to identify water supplies that could lead to Microbial Induced Corrosion (MIC). Such efforts may consist of discussions with the local water purveyor and/or fire official, familiarity with conditions in the local area, or laboratory testing of water supplies. When conditions are found that may result in MIC contamination of the fire protection piping, the engineer shall design corrective measures. 24 HOUR EMERGENCY SERVICE TOLL FREE 1.877.327.7823 www.Sprinklermatic.net