Product Range

advertisement
THE FIRST SOUND CONTROL SYSTEMS
TO MINIMISE THE RISK OF CORROSION
UNDER INSULATION (CUI)
Powered by TCPDF (www.tcpdf.org)
•
•
•
•
•
•
Combined thermal and acoustic properties
Effective "Built-in-barrier"
Significantly reduced insulation thickness and overall
system weight
Hot: Operating temperature: +20 °C to +250 °C
Cold: Operating temperature: -180 °C to +20 °C
Compliant to ISO 15665 Classes A to C and Shell DEP
31.46.00.31-Gen Class D. Satisfies ASTM E1222 and
acoustic classes 6, 7 and 8 according to NORSOK
R-004.
Resists UV, oil, chemicals and weathering
Powered by TCPDF (www.tcpdf.org)
Technical Data - ArmaSound Industrial Systems Cold [ES]
Brief description
ArmaSound Industrial Systems - Cold are high performance acoustic and thermal insulation solutions for industrial, petrochemical and offshore facilities.
The multi-layer systems (comprising of HT/Armaflex® Industrial, Armaflex® LTD, ArmaSound RD 240, ArmaSound Barrier E and Arma-Chek R coverings
or UV-cured GRP or metal cladding) reduce the risk of corrosion under insulation (CUI) and provide exceptional noise reduction while minimising total
system weight and thickness.
Material type
See product data sheets of individual components.
Colour
Colour of the covering / cladding: Grey
Product Range
ArmaSound Industrial Systems is available in different combinations (Classes A, B, C, D) and coverings (Arma-Chek R, UV-cured GRP or metal cladding).
Please ask Customer Service for the extended information on these systems.
Applications
Pipes, ducts and vessels in industrial, petrochemical and offshore facilities.
Special Features
Compliant to ISO 15665 Classes A to C and Shell DEP 31.46.00.31-Gen Class D.
Satisfies ASTM E 1222 and acoustic classes 6, 7 and 8 acc. to NORSOK R-004.
Assembly
The ArmaSound Industrial Systems Application manual should be consulted before assembly. Please consult our Customer Service Centre.
Remarks
For temperatures between -180 °C and -40 °C ArmaSound Industrial Systems may be combined with other insulation types to offer optimum acoustic
attenuation with improved service temperature capability. For detailed information on these specific systems please refer to our Customer Service
Centre.
Property
Value/Assessment
Special Remark
Temperature Range
Temperature Range
max. service temperature
+ 20 °C
(For temperatures above +20 °C, please
refer to ArmaSound Industrial Systems Hot)
min. service temperature
- 180 °C
(in combination with other insulation
types)
Thermal Conductivity
Thermal
Conductivity
System thermal perfomance depends on properties and configuration of individual layers
Refer to individual product data sheets
Water vapour diffusion resistance
Water vapour
diffusion resistance
System integrity depends on properties and configuration of individual layers
Refer to individual product data sheets
Other technical features
Biological / chemical
behaviour
Good
Resists oil and
chemicals.
UV resistance
Good
Resists UV and
weathering
All data and technical information are based on results achieved under typical application conditions. Recipients of this information should, in their own interest and responsibility, clarify with us in due time whether or not the data and information
apply to the intended application area. For temperatures below -40 °C please contact our Customer Service Centre to request the corresponding technical information. Armacell takes every precaution to ensure the accuracy of the data provided
in this document and all statements, technical information and recommendations contained within are believed to be correct. However, Armacell cannot guarantee that the data are 100 % accurate. Furthermore, minor deviations in colour, quality
and dimensions are unavoidable and in most cases do not influence the performance of the product. Armacell expressly disclaims any and all liability in relation to any results obtained or arising from any use of the product or reliance on such
information. No warranty of fitness for any particular purpose, warranty of merchantability or any other warranty, expressed or implied, is made concerning the goods described or the information provided herein. All the statements and technical
information within this document should be read in conjunction with the customer’s own specification. It is the responsibility of the recipient to inform all involved parties about the content of these documents. The described and recommended
methods should be strictly followed. If there is a requirement to deviate from our recommendations, please contact us in advance to discuss possible suitable alternatives. Armacell will not be liable for any claim resulting from a failure to observe
our specification or any other agreed solutions and from non-observance of the customer’s specification.
2
2015 Subject to alterations without prior notice - Our general conditions of sales & delivery shall apply
Technical Data - ArmaSound Industrial Systems Hot [ES]
Brief description
ArmaSound Industrial Systems - Hot are high performance acoustic and thermal insulation solutions for industrial, petrochemical and offshore facilities.
The multi-layer systems (comprising of HT/Armaflex® Industrial, ArmaSound RD 240, ArmaSound Barrier E and Arma-Chek R or UV-cured GRP or
metal cladding) reduce the risk of corrosion under insulation (CUI) and provide exceptional noise reduction while minimising total system weight and
thickness.
Material type
See product data sheets of individual components.
Colour
Colour of the covering / cladding: Grey
Product Range
ArmaSound Industrial Systems is available in different combinations (Classes A, B, C, D) and coverings (Arma-Chek R, UV-cured GRP or metal cladding).
Please ask Customer Service for the extended information on these systems.
Applications
Pipes, ducts and vessels in industrial, marine and offshore environments.
Special Features
Compliant to ISO 15665 Classes A to C and Shell DEP 31.46.00.31-Gen Class D.
Satisfies ASTM E 1222 and acoustic classes 6, 7 and 8 acc. to NORSOK R-004.
Assembly
The ArmaSound Industrial Systems Application manual should be consulted before assembly. Please consult our Customer Service Centre.
Remarks
For temperatures between 125 °C and 250 °C ArmaSound Industrial Systems may be combined with other insulation types to offer optimum acoustic
attenuation with improved service temperature capability. For detailed information on these specific systems please refer to our Customer Service Centre.
Property
Value/Assessment
Special Remark
Temperature Range
Temperature Range
max. service temperature
+ 250 °C
(For service temperatures above +
125 °C please contact our Customer
Service Centre.)
min. service temperature
+ 20 °C
(For temperatures below +20 °C, please
refer to ArmaSound Industrial Systems Cold)
Thermal Conductivity
Thermal
Conductivity
System thermal perfomance depends on properties and configuration of individual layers
Refer to individual product data sheets
Water vapour diffusion resistance
Water vapour
diffusion resistance
System integrity depends on properties and configuration of individual layers
Refer to individual product data sheets
Other technical features
Biological / chemical
behaviour
Good
Resists oil and
chemicals.
UV resistance
Good
Resists UV and
weathering.
All data and technical information are based on results achieved under typical application conditions. Recipients of this information should, in their own interest and responsibility, clarify with us in due time whether or not the data and information
apply to the intended application area. For temperatures below -40 °C please contact our Customer Service Centre to request the corresponding technical information. Armacell takes every precaution to ensure the accuracy of the data provided
in this document and all statements, technical information and recommendations contained within are believed to be correct. However, Armacell cannot guarantee that the data are 100 % accurate. Furthermore, minor deviations in colour, quality
and dimensions are unavoidable and in most cases do not influence the performance of the product. Armacell expressly disclaims any and all liability in relation to any results obtained or arising from any use of the product or reliance on such
information. No warranty of fitness for any particular purpose, warranty of merchantability or any other warranty, expressed or implied, is made concerning the goods described or the information provided herein. All the statements and technical
information within this document should be read in conjunction with the customer’s own specification. It is the responsibility of the recipient to inform all involved parties about the content of these documents. The described and recommended
methods should be strictly followed. If there is a requirement to deviate from our recommendations, please contact us in advance to discuss possible suitable alternatives. Armacell will not be liable for any claim resulting from a failure to observe
our specification or any other agreed solutions and from non-observance of the customer’s specification.
2015 Subject to alterations without prior notice - Our general conditions of sales & delivery shall apply
3
Armacell GmbH
Robert-Bosch-Straße 10 • 48153 Münster • Germany
Phone +49 (0) 251 / 76 03-0 • Fax +49 (0) 251 / 76 03-448
www.armacell.com • info@armacell.com
© Armacell Enterprise GmbH & Co. KG
Powered by TCPDF (www.tcpdf.org)
IPRN-0010-150618-en()
notes