CONTILED
FEATURES
Continous line lighting for tunnels






High visual comfort through continuous line lighting
Proven LensoFlex®2 photometrical engines
Flexible solution: extruded aluminium profile to adjust number of LEDs for tunnel requirements
Maximised savings in energy and maintenance costs
Future Proof : smart upgradability
Control system can be integrated into the backbone system
TYPES OF APPLICATION



Tunnels
Sports lighting
Railways stations and metros
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
1/11
DIMENSION DRAWING
DIMENSIONS AND CHARACTERISTICS
CONTL1 (CONTILED 1)
Length (mm)
Width (mm)
Height (mm)
Weight (kg)**
Tightness level*
Impact resistance*
Electrical class*
602
124
67
0
IP 66
IK 08
Class II EU
CONTL2 (CONTILED 2)
1202
124
67
0
* According to IEC-EN60598 and IEC-EN62262
** ** Average weight. The max weight is +/- 10% more but for the exact weight according to the configuration, please contact us.
SUMMARY
CONCEPT
Family of 2 tunnel LED luminaires
Recommended installation height: between 3 and 8m
A flexible solution to cover all the lighting requirements of the different tunnel areas, especially designed to offer a continuous
line lighting solution
Driver not incorporated for optimal heat dissipation
HOUSING & FINISH
•
Housing in extruded aluminium protected by electrolytic oxidation (class 15)
•
End caps: high-pressure, die-cast aluminium, polyester powder coated
•
Screws in stainless steel
•
Protector: thermally hardened glass
•
A door on one of the end caps provides access to the electronic compartment. Quick connectors allow easy connection
to the remote driver
•
Colour: RAL 9006 grey
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
2/11
INSTALLATION
•
2 fxation grooves on the bottom of the luminaire, intallation in any position on horizontal or vertical surface.
•
Assembly kit for luminiare lateral clamping
OPTICAL UNIT
•
Protected against lens degradation by 5mm thick extra clear hardened glass
•
Flatbed PCB with acrylic lens overlay principle
•
Various photometric distributions for lighting town, motorway and railway tunnels and underpasses
•
Symmetrical or asymmetrical photometry for excellent luminance uniformity
•
CRI > 70
•
ULOR: 0%
LED lumen depreciation
•
Lifetime residual flux @ Tq=25°C @ 100.000 hrs : 350mA&500mA:90% ; 700mA:80%
ELECTRICAL
•
Class I & II
•
Input voltage: 120-277V - 50-60Hz
•
Power factor > 90% at full load
STANDARDS & CERTIFICATIONS
•
CE
•
ENEC
•
LM79-80
•
ROHS
•
All measurements in ISO17025 accredited laboratory
OPTIONS
•
Other fixations
•
WW LEDs
•
Control system: Schréder Tunnel Control system
•
Control system: Dimming 1 -10V, DALI, Custom dimming profile, can be integrated into the backbone system
•
10kV surge protection
•
Electrical cabinet with drivers, fuses, connecting block and control unit
•
Interconnection cables
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
3/11
CONCEPT
1. FutureProof: Smart Upgradability
Since LED technology is constantly evolving, both the photometric engine and the gears can be replaced at the
end of the LEDs’ lifespan to take advantage of future technological developments
OPTIONS
1. Dimming without wireless remote management
Custom dimming profile; Constant Light Output (CLO); Bi-Power
dimming and Dali are available.
1.1 Custom Dimming
This option enables dimming profiles with up to 5 levels to adapt
the light according to the real needs during the night. The
dimming profile can be set up in two ways. The standard way
determines the dimming profiles based on the middle of the
night and is fully operational after 3 full nights. The second way
(on request) determines that the night starts from the moment
that the lights are switched on. The dimming profiles are
immediately operational.
1.2 Constant Light Output
This system compensates for the depreciation of luminous flux and
to avoid excess lighting at the beginning of the installation's service
life, providing substantial energy savings.
Standard lighting consumption
LED lighting consumption with CLO
Energy savings
1.3 Bi-Power functionality
In several countries an extra wire, a so-called control wire or switched line, is distributed throughout the street
lighting network.
In most cases, when the street lighting is switched on, both the line
and the switched line are energized to the 230V level. At a certain point during the night this switched line
is switched off from the grid. The bi-power driver detects this signal as a command to reduce the output current to a
lower preset value. In most cases this value equals 50%.
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
4/11
LUMEN AND POWER DETAILS
Typical data for Neutral White (NW) LEDs (4000 K, CRI min. 70) at Tq 25° C.
Model
Acronym
Colour
temp.
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
NW
Flux
code
Luminaire
power
(W)
Luminaire
efficacy
(lm/W)
001A0
001A1
001A2
001A3
002A4
002A5
003A6
003A7
003A8
005A9
005AA
006AB
Typical
luminaire
output
(lm)
1000
1300
1700
1900
2600
2900
3400
3900
3900
5100
5200
6800
Current
(mA)
Typical LED
flux
(lm)
LED
Count
8
11
16
16
23
24
32
34
31
48
45
65
125
118
106
119
113
121
106
115
126
106
116
105
350
500
700
350
500
350
700
500
350
700
500
700
1200
1600
2100
2400
3200
3600
4200
4900
4800
6300
6500
8400
8
8
8
16
16
24
16
24
32
24
32
32
001A0
002A1
002A2
003A3
003A4
003A5
004A6
005A7
005A8
005A9
006AA
006AB
006AC
007AD
007AE
008AF
009AG
010AH
010AI
011AJ
013AK
1900
2600
2900
3400
3900
3900
4800
5100
5200
5800
6500
6800
6800
7800
7900
8500
9200
10200
10500
11900
13600
16
23
24
32
34
31
39
48
45
47
57
65
55
63
68
81
80
97
91
113
129
119
113
121
106
115
126
123
106
116
123
114
105
124
124
116
105
115
105
115
105
105
350
500
350
700
500
350
350
700
500
350
500
700
350
350
500
700
500
700
500
700
700
2400
3200
3600
4200
4900
4800
6000
6300
6500
7200
8100
8400
8400
9600
9700
10500
11300
12600
13000
14700
16800
16
16
24
16
24
32
40
24
32
48
40
32
56
64
48
40
56
48
64
56
64
Note: The flux is an indicative average and may vary with the different optics and types of protector. Tolerance on LED flux is
± 7% and on total luminaire power ± 5 %.
The precise flux and corresponding matrix for each configuration are available on www.schreder.com
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
5/11
Typical data for Cool White (CW) LEDs (6200 K, CRI min. 70) at Tq 25° C.
Model
Acronym
Colour
temp.
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTILED 1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CONTL1
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTILED 2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CONTL2
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
Flux
code
Luminaire
power
(W)
Luminaire
efficacy
(lm/W)
001A0
001A1
001A2
001A3
002A4
002A5
003A6
003A7
003A8
005A9
005AA
006AB
Typical
luminaire
output
(lm)
1000
1300
1700
1900
2600
2900
3400
3900
3900
5100
5200
6800
Current
(mA)
Typical LED
flux
(lm)
LED
Count
8
11
16
16
23
24
32
34
31
48
45
65
125
118
106
119
113
121
106
115
126
106
116
105
350
500
700
350
500
350
700
500
350
700
500
700
1200
1600
2100
2400
3200
3600
4200
4900
4800
6300
6500
8400
8
8
8
16
16
24
16
24
32
24
32
32
001A0
002A1
002A2
003A3
003A4
003A5
004A6
005A7
005A8
005A9
006AA
006AB
006AC
007AD
007AE
008AF
009AG
010AH
010AI
011AJ
013AK
1900
2600
2900
3400
3900
3900
4800
5100
5200
5800
6500
6800
6800
7800
7900
8500
9200
10200
10500
11900
13600
16
23
24
32
34
31
39
48
45
47
57
65
55
63
68
81
80
97
91
113
129
119
113
121
106
115
126
123
106
116
123
114
105
124
124
116
105
115
105
115
105
105
350
500
350
700
500
350
350
700
500
350
500
700
350
350
500
700
500
700
500
700
700
2400
3200
3600
4200
4900
4800
6000
6300
6500
7200
8100
8400
8400
9600
9700
10500
11300
12600
13000
14700
16800
16
16
24
16
24
32
40
24
32
48
40
32
56
64
48
40
56
48
64
56
64
Note: The flux is an indicative average and may vary with the different optics and types of protector. Tolerance on LED flux is
± 7% and on total luminaire power ± 5 %.
The precise flux and corresponding matrix for each configuration are available on www.schreder.com
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
6/11
PHOTOMETRY
5068AS
Wide
5068SY
Symmetrical
Wide
5096AS
Medium
5096SY
Symmetrical
Medium
5098AS
Medium
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
7/11
5098SY
Symmetrical
Medium
5102AS
Medium
5102SY
Symmetrical
Medium
5103AS
Wide
5103SY
Symmetrical
Wide
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
8/11
5112AS
Wide
5112SY
Symmetrical
Wide
5117AS
Wide
5117SY
Symmetrical
Wide
5118AS
Medium
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
9/11
5118SY
Symmetrical
Medium
5119AS
Extra-wide
5119SY
Symmetrical
Extra-wide
5120AS
Asymmetrical 40°
5120SY
Symmetrical
Asymmetrical 40°
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
10/11
5121AS
Asymmetrical 60°
5121SY
Symmetrical
Asymmetrical 60°
ContiLED Product Sheet - 17/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com.
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
11/11
How to create valid ordering codes?
OPTICAL BLOCK
Go
to the Ordering Data page(s) and select one code per column in order to specify the characteristics of the Optical Block.
You may choose several options. Please refer to the footnotes to check compatibility between the selected features.
Choose
your Flux, Photometry and Control codes by referring to more detailled
information included in the Product Sheet.
Depending on your choice of colour temperature, please refer to the
corresponding table to find the flux code for the typical lumen package you require(*). Please check the Product ID to make sure that the
lumen package you need is available with the size you have chosen.
To choose the photometry, refer to the 4 digit codes beside the
curves and diagrams(*). AS = asymmetrical, SY = symmetrical and
BL = Back Light control.
The precise flux and corresponding matrix for each configuration are available on www.schreder.com
(*)
To configure the ideal solution between the features you need and
the available controllers, refer to the description in the Product
sheet.
exampleS of valid ordering codes for Optical Block
only with
standard
features
PRODxx - 00 - NW011A1 - 5119AS - GL01 - V00D00S0 - C000 - C000 - F0 - AM - A6 - 0B
Photometry
type
Universal
(2 digits)
with
customised
requests
Colour
(6 digits)
Protector
Product
temperature
type
ID
ISO 3166 + Flux code
(2 digits)
(6 digits)
country
(7 digits)
Custom
code
photometry
(2 digits)
(8 digits)
Controller +
Photocell +
Sensor
Options
(2 digits
Colour
(2 digits)
each)
Power
(4 digits)
Fixation
cable
type Custom con- (2 digits) Customised options (Photometry,
Specific RAL
(4 digits)
Cable, Label & Finishing) for which
trol, photo.
colour
you will receive a specific code
& sensor
(8 digits)
(4 digits)
(4 digits each)
PROdXX - AT - NW011a1 - CUSTOM - GL01 - V00D00S0 - C000 - C000 - F0 - PXXX - CXXX - LXXX - FXXX - RAL3005M
FIXATION
example
of a valid
ordering
code
Voltage &
electrical class
+ Dimming +
Electrical
protection
PRODFI - C1 - A
Fixation Fixation
ID
type
(6 digits)
(2 digits)
Others
(1 digit)
ORDERING DATA
CONTI LED
ID
PRODUCT
ID
OPTICAL BLOCK
COUNTRY
COUNTRY OF
COLOUR
FLUX
INSTALLATION TEMP
CODE
[1]
[2]
CONTL1
00
Universal
Standard
AO
Angola
CONTL2
GEARS
CONTROLS [4]
PHOTOM PROTECTOR
ETRY
TYPE [3]
VOLTAGE & EL.
CLASS
DIMMING
ELECTR. PROTECTION
POWER
CABLE
CABLE TYPE
CONTROLLER
PHOTO CELL
SENSOR
FIXATIONS
FIXATIONS
OPTIONS
OPTIONS [5]
COLOUR
COLOUR
NW
Neutral
White
5068AS
V00
No Driver
D00
No Dimming
S0
no SPD - no Fuse
C0
No Cable
00
No Cable
C0
No Controller
0
No Photocell
0
No Sensor
F0
No Fixation
N0
No Options
0J
RAL 9006 B
CW
Cold White
5098AS
AA
Special labeling
RALxxxx M
Other RAL colour
Matte
PXXX
Photometry
custom
RALxxxx B
Other RAL colour
Brilliant
CXXX
Cables custom
RALxxxx T
Other RAL colour
Textured
LXXX
Label custom
ZZ
Other specific
paint*
GL01
Flat Glass
5096AS
ZZ
CUSTOM
CABLE
5102AS
AR
Argentina
5103AS
5112AS
AU
Australia
5117AS
5118AS
…
5119AS
5120AS
5121AS
FXXX
Finishing Colour,
vernish, …
5068SY
5096SY
OXXX
Others
5098SY
5102SY
5103SY
5112SY
5117SY
5118SY
5119SY
5120SY
5121SY
CUSTOM*
Your Order
CONTL_
Example:
__
__
_ _ _ _ _ _ _ _ _ _ _ GL01
V00
D00
S0
C0
00
C0
CONTL2-BE-NW013AK-5102AS-GL01-V00D00S0-C000-C000-F0-N0-0J
Notes: +++ The luminaire has an CL II isolation +++ No earth is connected inside the luminaire. +++ However, the customer can declare the installation Class I, if the driver (inside the driver Box) is earthed.
[1] Please provide country of installation to ensure country specific settings are taken into account. Schréder will provide you the code to use (00 (universal standard) or the country's ISO code).
[2] See further Lumen and Power details table. [3] See further Photometrics table.
[4] Schréder fixtures are compatible with most controls equipment available on the market. Please contact Schréder for more information.
[5] Multiple SELECTIONS and VARIANTS concatenation possible eg. -A2-AA-P0Z0-D0W0-C0Y0-S0M0-L0H0.
*Please contact Schréder to specify your requirement. A custom requirement must be validated by Schréder and may impact the delivery leadtime.
ContiLED Product Sheet - 13/03/2015 - To make sure this is the most recent revision, please consult www.schreder.com
Copyright © 2015 Schréder SA. All rights reserved. Specifications are of an indicative nature and subject to change without notice.
0
0
F0
_ _
_
BOX 4
ContiLED
COLOUR
Mounting Fixation
ID
C1
luminaire lateral clamping
Your Order
CONTFI
C1
Example
CONTFI-C1-A
COLOUR
Others
Colour
A
No
Painting
A
0