SolarRiver Series Inverter Installation &DC/AC Terminal Disconnection Guide Wall bracket Use the wall bracket as a drilling template and mark the positions of the drill holes Wall bracket Use at least five holes Hang the Solar River The Solar River tilted slightly upward; Attach the Solar River to the wall bracket slightly to the top of its final position Hang the Solar River Top side Bottom side Check the hanging After hanging the Solar River, check both left and right sides to ensure that it is correctly in place Screw Screw the bottom side DC cable wiring Step 1 Put the threaded sleeve and pressure screw through the DC wire(refer to figure 1 to figure 5) Step 1 Put the threaded sleeve and pressure screw through the DC wire Bare wire length about 7mm 1 3 2 4 5 DC cable wiring Step 2 Crimping the terminal DC cable wiring Step 3 insert into plastic terminal Positive Terminal Negative Terminal DC cable wiring Step 4 Screw down the threaded sleeve and the pressure screw Positive Terminal Negative Terminal AC cable wiring Step 1 Put the threaded sleeve and pressure screw through the AC wire Bare wire length about 7mm AC cable wiring Step 2 Wire the AC wire refer to below instructions. ·Screw the green-yellow wire to the ground terminator in the AC Connector ·Screw the blue wire to the N(Neutral) terminator in the AC Connector. ·Screw the brown wire to the L(Line) terminator in the AC Connector. AC cable wiring Step 3 Confirm all the wires should be screwed down AC cable wiring Step 4 Screw down the threaded sleeve and the pressure screw SolarRiver DC/AC Terminal Disconnection Guide Figure Description Tools Disconnect the positive DC terminal 1.Use the Wrench Tool, insert it on the back of the positive DC terminal adaptor.(Figure 1),the obvious position as Figure 2. Figure 1 Universal unlocking tool Manufacture: AMPHENOL Note: For SolarRiver 1100TL,1600TL,1700TL,2300TL,300TL, both Wrench Tool and Universal Unlocking Tool are suitable for this step. For SolarRiver 3300TL,4400TL,5200Tl,only Wrench Tool is suitable for this step. Figure 2 Wrench Tool Manufacture: AMPHENOL 2.When you hear a “click “,it means the Wrench Tool is fully inserted (Figure3),then you can pull out the positive DC terminal adaptor as Figure 4. Figure 3 Figure 4 SolarRiver DC/AC Terminal Disconnection Guide Description Figure Disconnect the Negative DC terminal 1.Use the Wrench Tool, insert it on the back of the Negative DC terminal adaptor.(Figure 5),the obvious position as Figure 6. Note: For SolarRiver 1100TL,1600TL,1700TL,2300TL,300TL, both Wrench Tool and Universal Unlocking Tool are suitable for this step. For SolarRiver 3300TL,4400TL,5200Tl,only Wrench Tool is suitable for this step. Figure 5 Figure 6 2.When you hear a “click” it means the Universe Unlocking Tool is fully inserted (Figure7), then you can pull out the negative DC terminal adaptor as figure 8. Figure 7 Figure 8 SolarRiver DC/AC Terminal Disconnection Guide Description Figure Disconnect the AC terminal 1.Use the screw driver to press the click on the AC terminal adaptor(Figure 9),the obvious position as Figure 10. Figure 9 2.Pull out the AC terminal adaptor as Figure 11. Figure 11 Figure 10 • • • • • • • • • • • Samil Power Co., Ltd. Sales Center Address:No.52,Huigu Innovation Park Huishan District Wuxi, Jiangsu Province, China Postal Code:214174 Tel:+86(0)510 83593131 Fax:+86(0)510 81819678 E‐mail:info@samilpower.com After Sales: Tel:+86(0)510 8358 9215 ;+86(0)510 8358 9208 ; +86(0)510 8358 9213 Fax:+86(0)510 8181 9678 Email: service@samilpower.com