Burger King Remodel Sheet Index THESE PLANS ARE DRAWN USING A LEGEND FORMAT. THE LEGENDS ON EACH SHEET EXPLAIN THE MANY SYMBOLS USED THROUGHOUT THE PLANS. A-1.0 COVER SHEET SP-1 SITE PLAN & DETAILS D-1.0 DEMOLITION FLOOR PLAN D-2.0 DEMOLITION CEILING PLAN A-2.0 FLOOR PLAN A-2.1 ENLARGED FLOOR PLAN & INTERIOR ELEVATIONS A-3.0 CEILING PLAN A-3.1 ROOF PLAN THIS PROJECT IS FOR A REMODEL OF AN EXISTING BURGER KING RESTAURANT. THE REMODEL INCLUDES UPDATING THE EXTERIOR AND INTERIOR TO BURGER KING'S CURRENT BRAND STANDARDS. A-4.0 ROOM FINISH & DOOR SCHEDULES A-4.1 DOOR SCHEDULE THERE WILL ALSO BE UPDATES FOR ADA COMPLIANCE. THIS INCLUDES RECONFIGURATION OF THE RESTROOMS AND UPDATING EXTERIOR SIDEWALKS AND RAMPS FOR COMPLIANCE. A-5.0 EXTERIOR ELEVATIONS A-5.1 EXTERIOR FINISH SCHEDULE A-6.0 WALL SECTIONS A-6.1 WALL SECTIONS Project Scope of Work A-6.2 WALL SECTIONS A-7.0 DETAILS - ARCHITECTURAL THIS PROJECT IS A REMODEL PROJECT OF AN EXISTING BUILDING. PROPOSED WORK INCLUDES: A-7.1 DETAILS - ARCHITECTURAL A-8.0 MANUFACTURERS & SUPPLIERS DIRECTORY E-1 POWER PLAN E-2 LIGHTING PLAN E-3 PANEL SCHEDULE / ONE LINE DIAGRAM A SYMBOL SHOWN IN A LEGEND DOES NOT NECESSARILY MEAN THAT THE ITEM OCCURS WITHIN THE SCOPE OF THIS PROJECT. REVIEW THE PLANS AND SPECIFICATIONS CAREFULLY TO DETERMINE THE COMPLETE SCOPE OF WORK. Store #14011 6495 Labeaux Ave. NE Albertville, MN. Specifications How to read these plans. About this project... Location Map THESE SPECIFICATIONS CONTAIN IMPORTANT INFORMATION RELATING TO BUILDING CODES, CITY ORDINANCES, MATERIALS, AND METHODS. DEMOLITION: - WALLS, CEILINGS, FIXTURES, ETC. AS SHOWN ON THE DEMO PLAN. IMPROVEMENTS AS NECESSARY, SEE DIVISION 2 OF SPECIFICATIONS. DIVISION 1 INSTRUCTIONS TO BIDDERS EXTERIOR: 1.1 THESE DOCUMENTS ARE TO BE BID AS AN ENTIRE PACKAGE. NO CONSIDERATION WILL BE GIVEN TO THE CONTRACTOR/SUBCONTRACTORS FOR ITEMS OMITTED DUE TO BIDDING OF PARTIAL DOCUMENTS. INTERIOR: 2.1 VISIT THE SITE BEFORE SUBMITTING YOUR FINAL BID AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. NO CONSIDERATION WILL BE GIVEN TO THE CONTRACTOR/SUBCONTRACTORS FOR ITEMS OMITTED DUE TO LACK OF KNOWLEDGE OF EXISTING UNCONCEALED SITE CONDITIONS. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED - UPDATING THE SITE ACCESSIBILITY AS SHOWN ON THE SITE PLAN - UPDATING THE EXTERIOR BUILDING FINISHES - ALL EXTERIOR SIGNAGE WILL BE UNDER SEPARATE PERMIT. architecture.us phone: 1.888.666.0931 Project Team: - NON-LOAD BEARING INTERIOR PARTITIONS - ROOM FINISHES TO INCLUDE PAINT, TILE, AND ACOUSTICAL CEILING. MECHANICAL: - ROOF TOP UNITS ARE EXISTING. - MECHANICAL SYSTEM IS EXISTING AND WILL NOT BE MODIFIED FOR THIS PROJECT. RELOCATE DIFFUSERS AND GRILLES AS REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION. RE-BALANCE AS REQUIRED. 3.1 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS ALWAYS TAKE PRECEDENCE OVER THE SCALE OF A DRAWING. PLUMBING: 4.1 INCLUDE IN YOUR BID THE FOLLOWING ADDITIONAL ITEMS: a. ITEMS TO BE REMOVED IN ORDER TO COMPLETE THE PROJECT. REFER TO DIVISION 2. b. ITEMS TO BE RELOCATED IN ORDER TO COMPLETE THE PROJECT. REFER TO OTHER DIVISIONS WITHIN THESE SPECIFICATIONS. ELECTRICAL: - ADD OUTLETS FOR GENERAL USE - MODIFY LIGHT FIXTURES - ELECTRICAL PANELS ARE EXISTING 5.1 IF YOU SHOULD FIND APPARENT CONFLICTS IN, OR OMISSIONS FROM THESE DOCUMENTS OR BE IN DOUBT AS TO THEIR MEANING, CONTACT ONE ARCHITECTURE IN WRITING PRIOR TO SUBMITTING A FINAL BID. FIRE ALARM: - NOT INCLUDED UNDER THIS PERMIT. SEE GENERAL NOTES THIS SHEET. 7.1 ANY INTERPRETATION, CORRECTION OR CHANGE OF THE BIDDING DOCUMENTS WILL BE MADE BY ADDENDUM. INTERPRETATIONS, CORRECTIONS OR CHANGES OF THE BIDDING DOCUMENTS MADE IN ANY OTHER MANNER WILL NOT BE BINDING, AND BIDDERS SHALL NOT RELY UPON SUCH INTERPRETATIONS, CORRECTIONS AND CHANGES. (SEE PLANS FOR FULL DESCRIPTION OF WORK) 8.1 SUBSTITUTIONS a. NO SUBSTITUTIONS WILL BE CONSIDERED DURING THE BIDDING PERIOD. b. CONTRACTOR'S BIDS SHALL BE BASED ON PROVIDING MATERIALS AND EQUIPMENT AS SPECIFIED. c. THE MATERIALS, PRODUCTS, AND EQUIPMENT DESCRIBED IN THE BIDDING DOCUMENTS ESTABLISH A STANDARD OF REQUIRED FUNCTION, QUALITY TO BE MET BY ANY PROPOSED SUBSTITUTION. d. THERE SHALL BE NO SUBSTITUTIONS UNLESS AN ITEM IS SPECIFICALLY DESIGNATED AS "OR EQUAL." ALL OTHER ITEMS SHALL BE PROVIDED EXACTLY AS SPECIFIED. e. SUBSTITUTIONS FOR ITEMS SPECIFIED "OR EQUAL" SHALL BE CONSIDERED ONLY AFTER BIDS HAVE BEEN SUBMITTED. THE BURDEN OF PROOF OR MERIT OF THE PROPOSED SUBSTITUTION IS UPON THE PROPOSER. THE ARCHITECT'S DECISION OF APPROVAL OR DISAPPROVAL OF A PROPOSED SUBSTITUTION SHALL BE FINAL. A. SITE IMPROVEMENTS, LANDSCAPING, PARKING, SHELL STRUCTURE, WATER AND SEWER MAIN LINES, AND ELECTRICAL DISTRIBUTION ARE EXISTING SYSTEMS AND ARE TO BE MODIFIED ONLY TO THE EXTENT SHOWN IN THESE DOCUMENTS. 10.1 CONTRACTOR, DURING PRE-BID SITE VISIT, SHALL TAKE NOTICE OF ANY VISUALLY APPARENT CODE VOILATIONS AND ALLOW IN HIS/HER BID FOR CORRECTING SUCH VIOLATIONS. B. ALL PRODUCTS LISTED BY ICC, UL OR EQUIVALENT NUMBERS SHALL BE INSTALLED PER THE REPORT AND MANUFACTURER'S WRITTEN INSTRUCTION. PRODUCT SUBSTITUTION FOR PRODUCTS LISTED SHALL ALSO HAVE AN APPROVED EVALUATION REPORT OR BE APPROVED AND LISTED BY OTHER NATIONALLY RECOGNIZED TESTING AGENCIES. CONTRACTOR'S RESPONSIBILITIES 1.1 THE CONTRACTOR SHALL FILE FOR ALL REQUIRED INSPECTIONS WITH ALL APPLICABLE AGENCIES. 2012 2012 2012 2012 2012 2012 2012 2012 INTERNATIONAL BUILDING CODE INTERNATIONAL MECHANICAL CODE INTERNATIONAL PLUMBING CODE NATIONAL ELECTRICAL CODE INTERNATIONAL FUEL GAS CODE INTERNATIONAL ENERGY CONSERVATION CODE INTERNATIONAL EXISTING BUILDING CODE INTERNATIONAL FIRE CODE EXISTING ZONING: C-2 CONSTRUCTION TYPE: V-B BUILDING AREA: OCCUPANCY TYPE: with A.F.E.S. 4035 s.f. (EXISTING) A-2, RESTAURANT OCCUPANT LOAD: ACCESSORY STORAGE, MECH EQUIP: 2.1 THE CONTRACTOR SHALL PAY ALL PERMIT FEES, IMPACT FEES, UTILITY FEES, AND ANY OTHER FEES ASSOCIATED WITH THE PERMIT AND INSPECTION PROCESS. C. FIRE SPRINKLER APPROVALS ARE NOT INCLUDED UNDER THIS PERMIT. BEFORE COMMENCING ANY WORK ON THE SPRINKLER SYSTEM, PLANS MUST BE SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT. THE SYSTEM MUST BE INSPECTED AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO A CERTIFICATE OF OCCUPANCY. OWNER'S OBLIGATIONS 1.1 THE OWNER WILL PAY FOR ALL CHANGES TO THE WORK RESULTING FROM CONDITIONS THAT COULD NOT HAVE BEEN KNOWN TO THE CONTRACTOR OR ONE ARCHITECTURE BY VISUAL INSPECTION OF THE SITE. D. FIRE ALARM SYSTEM APPROVALS ARE NOT INCLUDED UNDER THIS PERMIT. BEFORE COMMENCING ANY WORK ON THE ALARM SYSTEM, PLANS AND CUT SHEETS MUST BE SUBMITTED TO AND APPROVED BY THE BUILDING DEPARTMENT. THE SYSTEM MUST BE INSPECTED AND APPROVED BY THE BUILDING DEPARTMENT PRIOR TO A CERTIFICATE OF OCCUPANCY. 2.1 THE OWNER WILL MAKE THE SITE ACCESSIBLE TO THE CONTRACTOR DURING THE PERIOD OF CONSTRUCTION, AND WILL NOT HOLD THE CONTRACTOR RESPONSIBLE FOR TIME DELAYS OR COST INCREASES CAUSED BY OWNER OR TENANT ACTIONS. DIVISION 3 E. ALL EXISTING MATERIALS AND FINISHES THAT ARE TO REMAIN ARE TO BE PROTECTED DURING DEMOLITION AND CONSTRUCTION AGAINST DAMAGE AND SOILING. CONTRACTOR IS RESPONSIBLE TO REPAIR OR REPLACE ANY ITEMS DAMAGED WHICH ARE NOT PART OF THE SCOPE OF WORK SHOWN ON THESE DRAWINGS AT THE CONTRACTORS EXPENSE. CONCRETE 1.1 CLEAN, GRIND, FILL AND LEVEL ALL EXISTING CONCRETE TO RECEIVE NEW FLOORING, STAINING OR SEALING. 751 / 300 = 02.50 USE 3 Revisions ASSEMBLY TABLES & CHAIRS: 1923 / 15 = 128.2 USE 129 OFFICE: 105 / 100 = 01.05 USE 1 KITCHENS (COMMERCIAL): 795 / 200 = 03.96 USE 4 TOTAL: EXITS REQUIRED: EXITS PROVIDED: 135.71 USE 137 2 3 (EXISTING) Parking Calculations Vicinity Map 4.1 ALL TRENCHES SHALL BE BACKFILLED IN LIFTS OF NOT GREATER THAN 6" AND RECOMPACTED TO 90% OF EXISTING SOIL/PAD COMPACTION. FOR THIS PROJECT: DIVISION 17 ACCESSIBILITY REQUIREMENTS 1.1 ALL WORK SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT ARCHITECTURAL GUIDELINES (ADAAG) AND ANSI STANDARDS A-117.1, LATEST EDITION. PARKING REQUIRED: THIS PROJECT BURGER KING 50 EXISTING SPACES (INCLUDING 3 ACCESSIBLE SPACES) TO REMAIN, NO CHANGE WITH THIS PROJECT. 3.1 ALL DOOR HANDLES SHALL BE LEVER TYPE. CENTER OF LEVER TO BE INSTALLED 36" ABOVE FINISH FLOOR. 4.1 LAVATORY FAUCETS SHALL BE LEVER TYPE. 5.1 HOT WATER AND DRAINPIPES UNDER LAVATORIES SHALL BE INSULATED. 6.1 TOILET PAPER DISPENSER SHALL BE CONTINUOUS FLOW TYPE. Status of Documents THIS PROJECT 7.1 FLUSH CONTROL VALVE AT WATER CLOSET SHALL BE ON THE WIDE SIDE OF THE CLOSET AND MOUNTED AT NO GREATER THAN 42" ABOVE THE FINISH FLOOR. THESE PLANS ARE ISSUED FOR BIDDING AND PERMITTING. FINAL PLANS FOR CONSTRUCTION WILL BE ISSUED AFTER APPROVAL BY ALL GOVERNING AGENCIES. AGENCY ITEMS AND ADDENDA ITEM, IF ANY, WILL BE ADDED TO FINAL PLANS AND WILL BE PROPERLY NOTED AS SUCH. Project Description: 2.1 ALL THRESHOLDS SHALL BE A MAXIMUM 1/2" HEIGHT AND BEVELED. Albertville, MN 3.1 BACK POURED CONCRETE, WHERE SAW CUTTING HAS OCCURRED, SHALL BE SMOOTH AND LEVEL AND HAVE A FINISH TO MATCH THE ADJACENT CONCRETE. USE 2,500 PSI CONCRETE OR HIGHER. PROVE #4 X 12" REBAR DOWELS AT 48" O/C, DRILLED AND DOWELED INTO SIDE OF CONCRETE AT ALL SAW CUT TRENCHES. Store #14011 6495 Labeaux Ave, NE. PER 10 FEET. Burger King 4" THIS PROJECT SHALL ADHERE TO THE FOLLOWING CODES: Project Information General Notes 9.1 CONTRACTORS ARE CAUTIONED TO COORDINATE ITEMS IN THEIR SCOPE OF WORK WITH OTHER TRADES. 1 City of Albertville Construction Codes FIRE SPRINKLER:- NOT INCLUDED UNDER THIS PERMIT. SEE GENERAL NOTES THIS SHEET. 6.1 THE CONTRACTOR SHALL GIVE ONE ARCHITECTURE 48 HOURS TO RESEARCH AND REPLY TO ALL QUESTIONS. ONLY WRITTEN RESPONSES FROM ONE ARCHITECTURE SHALL BE CONSIDERED VALID CHANGES TO THE SCOPE OF WORK. 2.1 FLOORS TO RECEIVE SHEET VINYL OR CERAMIC TILE SHALL NOT VARY MORE THAN - MODIFY THE EXISTING RESTROOM(S) TO MEET ACCESSIBILITY STANDARDS - EXISTING KITCHEN PLUMBING FIXTURES TO REMAIN RAN # / ST-000 -Month 00, 0000 N N COPYRIGHT 2015, ONE ARCHITECTURE, PLC A-1.0 Cover Sheet Keynotes WIDTH VARIES (SEE PLAN) 1' SAWCUT (MIN) 6" 1. EXISTING CONCRETE CURB AND GUTTER, TYPICAL. 3. EXISTING SIDEWALK, TYPICAL. 4. EXISTING PAVED PARKING / DRIVEWAY, TYPICAL. 18" 4" 8" 5" OR 6" (SEE PLAN) 2. PROPERTY LINE. 4" 5. EXISTING SITE LIGHT. OUTLETS 6. 4" THICK CONCRETE SIDEWALK, SEE DETAIL 5 ON THIS SHEET. 7. CONCRETE ACCESSIBLE SIDEWALK RAMP, SEE DETAIL 6 ON THIS SHEET. 8. EXISTING ASHPALT PAVING TO BE REMOVED AND REPLACED IN THE DOTTED AREA. RESTRIPE PARKING AS SHOWN WITH 4" PAINTED WHITE STRIPES. 8" 9. PROVIDE CONCRETE WHEELSTOP AT ACCESSIBLE SPACES, TYPICAL. SEE DETAIL 3 & 6 ON THIS SHEET. 191'-4" architecture.us phone: 1.888.666.0931 10. 6" CONCRETE CURB, SEE DETAIL 2 ON THIS SHEET. 11. CONCRETE ACCESSIBLE SIDEWALK RAMP WITH RETURN CURBS. RAMP TO TRANSITION FROM HIGHER SIDEWALK AT BUILDING ENTRY TO LOWER SIDEWALK AT PARKING, SEE DETAIL 6 ON THIS SHEET, SIMILAR . 1 18'-0" Vertical Concrete Curb, Pavement & Sidewalk 12. ACCESSIBLE PARKING SIGN, TYPICAL AT EACH ACCESSIBLE SPACE. SEE DETAIL 4 & 6 ON THIS SHEET. 17 13. GENERAL CONTRACTOR TO REPLACE EXISTING RED ENTRY DOORS AND HARDWARE. NO PAINT SILVER ALUMINIUM REMAINS. SCALE: 1" = 1'-0" 24'-0" 35' BUILDING SETBACK LINE General Notes 9'-0" 20'-0" 139'-1" 25'-2" 18" 5" OR 6" (SEE PLAN) 6" A. GENERAL CONTRACTOR TO REMOVE ALL EXISTING ENTRY ACCESS CURBS AND REPLACE WITH NEW ENTRY ACCESS CURBS MEETING CURRENT ADA STANDARDS. SEE DETAIL 6 ON SHEET SP-1. 23 B. GENERAL CONTRACTOR IS TO REPAIR / REPLACE ALL CRACKED AND DAMAGED CONCRETE AROUND THE EXTERIOR OF THE BUILDING. GENERAL CONTRACTOR TO VERIFY WITH OWNER THE EXACT LOCATIONS TO BE REPAIRED. GENERAL CONTRACTOR TO PAY CLOSE ATTENTION OF THE MAIN ENTRY TO THE BUILDING AND DRIVE-UP TO THE TRASH ENCLOSURE. RA 24'-0" P E. GENERAL CONTRACTOR TO REPAIR EXISTING DENTS AT ALUMINUM TRIM AROUND THE BUILDING. F. GENERAL CONTRACTOR TO REPAINT ALL EXISTING BOLLARDS. VERIFY COLOR WITH OWNER. -0" 10'-8 " 18' EXISTING BURGER KING 4035.00 S.F. G. GENERAL CONTRACTOR TO DISCUSS WITH THE OWNER ABOUT WHAT IS GOING TO OCCUR WITH THE EXISTING BURGER KING SITE SIGNAGE. EXISTING SIGN MAY GO ON A NEW 15' POLE. LIGHTING THE BK SIGNAGE TO BE LED. INE KL ING ILD U B 10' WETLAND BUFFER AREA 7'-0" SE H. ALL NEW SIGNAGE TO BE PROVIDED BY OWNER AND INSTALLED BY OWNER. I. GENERAL CONTRACTOR TO PAINT THE EXISTING UTILITY BOXES AT THE BACK OF THE BUILDING. COLOR TO BE EP-4. J. INSTALL A NEW LED LIGHT BAND AT THE BUILDING PARAPET. PARAPET BAND INSTALLED BY OWNER AS PART OF THE SIGNAGE PACKAGE. 144'0" '-2" 200 K. GENERAL CONTRACTOR TO INSTALL A NEW 2" ELECTRICAL CONDUIT TO THE EXISTING DRIVE-THROUGH MENU BOARDS. CONDUIT TO BE USED FOR FUTURE DIGITAL DRIVE-THRU MENU BOARDS. 3" 3''-0" R39'-8" 1/2" 6" D. GENERAL CONTRACTOR TO PATCH, SEAL AND RE-STRIPE THE EXISTING PARKING LOT. PARKING COUNT TO REMAIN THE SAME. AC TB SCALE: 1" = 1'-0" 7" -0" M RA Vertical Concrete Curb Adjacent to Pavement C. ALL EXISTING PARKING LOT LIGHTING TO BE REPLACED WITH NEW LED LIGHT FIXTURES. GENERAL CONTRACTOR TO PROVIDE AND INSTALL. REFER TO LIGHTING SCHEDULE ON SHEET E-3 FOR FIXTURE TYPE. EXISTING LIGHT POLES TO REMAIN, GENERAL CONTRACTOR TO PAINT POLES (BLACK). 11 -0" 18' 2 19' MP -0" 24' 2 R3'-3" WETLAND BUFFER AREA " 0'-9 R4 Project Team: L. GENERAL CONTRACTOR TO VERIFY WITH OWNER REGARDING EXTERIOR FURNITURE. ANY FURNITURE TO REMAIN SHALL BE PAINTED. AREAS WHERE FURNITURE IS TO BE REMOVED SHALL BE DISCOVERED. WETLAND BUFFER AREA M. INSTALL A NEW CLEARANCE BAR AT THE DRIVE-THROUGH. Revisions '-3 46 N. GENERAL CONTRACTOR TO REMOVE THE EXISTING ROOF AND INSTALL A NEW DUROLAST MEMBRANE ROOF. " O. GC PROVIDE NEW FOOTING FOR OCU AND CANOPY. OCU/CANOPY INSTALLED BY OWNER. 6" P. PROVIDE ELECTRICAL FOR WALL SIGNAGE 40' 1" = 20'-0" 3 Precast Concrete Wheelstop SCALE: NOT TO SCALE RESERVED PARKING VAN Project Description: 1" 5'-0" VARIES (SEE PLAN) CROSS SLOPE: MAX 2% MIN 1% (FOR DRAINAGE) ACCESSIBLE Albertville, MN 20' Store #14011 6495 Labeaux Ave, NE. Site Plan 10' Burger King N 0 RAN # / ST-000 -Month 00, 0000 4 Accessible Parking Sign SCALE: NOT TO SCALE 5 Concrete Sidewalk SCALE: 1/2" = 1'-0" 6 Accessible Parking - Ramp Walk SCALE: NOT TO SCALE SP-1 Site Plan Demolition Wall Legend CMU WALL CMU WALL, WITH FURRING WALL TO BE REMOVED Existing Walls EXISTING WALL Doors SEE DETAIL A5, SHEET A-7.0 FOR REQUIRED DOOR CLEARANCES. architecture.us phone: 1.888.666.0931 EXISTING DOOR OR PAIR OF DOORS. Project Team: EXISTING DOOR OR PAIR OF DOORS TO BE REMOVED. EXISTING DOOR OR PAIR OF DOORS TO BE RELOCATED. (RELOCATE TO LOCATION OF CORRESPONDING NEW DOOR). POCKET DOOR. Windows EXISTING WINDOW WINDOW TO BE REMOVED Specifications DIVISION 2 DEMOLITION 1.1 REMOVE ALL EXISTING FLOORING, WALLS, DOORS, CEILINGS, CASEWORK, ETC. AS REQUIRED TO ALLOW FOR ALL NEW WORK. 2.1 REMOVE OR RELOCATE ALL COMPONENTS OF THE MECHANICAL, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS AS REQUIRED TO ALLOW FOR ALL NEW WORK. RELOCATION OF ITEMS TO REMAIN SHALL COMPLY WITH ALL CODES AND ORDINANCES. 3.1 WHERE DEMOLITION HAS OCCURRED, REPAIR OR REPLACE ANY REMAINING FLOORS, WALLS OR CEILINGS TO "LIKE NEW" CONDITION. MATCH ADJACENT NEW FINISHES. 4.1 OWNER WILL OCCUPY PORTIONS OF BUILDING IMMEDIATELY ADJACENT TO DEMOLITION AREA. CONDUCT DEMOLITION SO OWNER'S OPERATIONS WILL NOT BE DISRUPTED. 5.1 EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING DEMOLITION, BY METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING WARRANTIES. 6.1 VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION OPERATIONS. 7.1 SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO DETERMINE EXTENT OF DEMOLITION REQUIRED. 8.1 WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO ARCHITECT. 9.1 EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING DEMOLITION AND REINSTALLED IN THEIR ORIGINAL LOCATIONS AFTER DEMOLITION OPERATIONS ARE COMPLETE. Revisions 10.1 CLEAN ADJACENT SURFACES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE DEMOLITION OPERATIONS BEGAN. 13.1 LEGEND SYMBOLS ARE TYPICAL AND LOCATIONS ARE APPROXIMATE AND ARE NOT INTENDED TO LIMIT THE AMOUNT OF DEMOLITION WORK. COORDINATE WITH EXISTING CONDITIONS AND THESE NOTES AND REMOVE ALL APPLICABLE SYSTEMS AND COMPONENTS CONFLICTING WITH FINISHED DESIGN INTENT. 14.1 ALL DEBRIS AND MATERIALS FROM THE BUILDING SHALL BE DISPOSED OF OFF THE SITE IN A LEGAL MANNER. NO RECLAIMED LUMBER OR MATERIALS SHALL BE RE-USED EXCEPT AS SPECIFICALLY APPROVED BY THE ARCHITECT OR OWNER. 15.1 WHERE DEMOLITION AND CUTTING WORK HAS OCCURRED OR WHERE EXISTING SURFACES, MATERIALS OR OTHER ITEMS HAVE BEEN DAMAGED OR DISTURBED AS A RESULT OF THIS CONTRACT, THE SAID SURFACES AND AREAS SHALL BE CAREFULLY CLOSED UP, PATCHED AND FINISHED, AND/OR RESTORED AS REQUIRED TO BE CONTIGUOUS TO EXISTING SURROUNDING SURFACES. Demo Floor Plan Keynotes 1. GENERAL CONTRACTOR TO REMOVE THE EXISTING PLAY LAND EQUIPMENT AND PREPARE THE SPACE FOR DECOR. 9. EXISTING QUE LINE SHALL BE REMOVED. CONTRACTOR SHALL PATCH/REPAIR THE EXISTING FLOOR AS REQUIRED. 2. EXISTING HAND DRYER TO BE REMOVED. 10. REMOVE THE EXISTING SURFACE MOUNTER ELECTRIC WIRING AND JUNCTION BOX ON WALL OUT SIDE OF THE PLAY LAND 16.1 WHERE ELECTRICAL NEEDS TO BE ABANDONED, REMOVE WIRE FROM OUTLET ALL THE WAY BACK TO THE ELECTRICAL PANEL/SOURCE. ALL WORK SHALL BE DONE BY A LICENSED ELECTRICIAN. 3. EXISTING ELECTRICAL PANEL(S), TO REMAIN. 4. GC TO REMOVE THE EXISTING DOOR AND FRAME IN BETWEEN THE PLAY LAND AND 12. REPLACE DAMAGED FRP PANELS WITH NEW TO MATCH EXISTING 5. EXISTING LOW DIVIDER AND QUE LINES TO BE REMOVED. CONTRACTOR SHALL PATCH/REPAIR THE EXISTING FLOOR AS REQUIRED. 13. REPLACE ALL DAMAGED FLOOR BASE TILE 6. GENERAL CONTRACTOR TO REMOVE THE EXISTING TILE FLOOR AND PREPARE SLAB BACK TO STUDS AND START AGAIN. General Notes A. ALL ITEMS SHOWN ON THIS PLAN WITH SOLID LINES ARE EXISTING TO REMAIN. ALL ITEMS SHOWN WITH DASHED LINES ARE TO BE DEMO'D OR REMOVED AS NOTED. 15. REMOVE THE RED LAMINATE TRIM AT THE UNDERSIDE OF THE MENU BOARD AND REPLACE WITH A U-SHAPED ALUMINUM CAP. REPLACE WITH NEW ALUMINUM TRIM OR WRAP EXISTING LAMINATE WITH ALUMINUM 17.1 WHERE PLUMBING NEEDS TO BE ABANDONED, REMOVE ALL VENT STACK PIPE CAP & ROOF PENETRATION. REMOVE ALL OVERHEAD WATER LINES BACK TO POINT OF ENTRY (CAREFULLY VERIFY IF ANY LINES CAN BE RE-UTILIZED AS PART OF NEW BUILD OUT). ALL UNDERGROUND SANITARY, GREASE OR WATER LINES SHALL BE CAPPED-OFF BELOW SLAB. MAKE SURE ALL WATER HAS BEEN TURNED OFF PRIOR TO ANY WORK. ALL WORK SHALL BE DONE BY A LICENSED PLUMBER. 18.1 WHERE GAS LINES OR SERVICE NEEDS TO BE ABANDONED, CAREFULLY REMOVE ALL PIPING, SHUT-OFF VALVES & FITTING AS REQUIRED. GAS METER & REGULATOR SHALL BE REMOVED BY UTILITY COMPANY. ALL WORK TO BE DONE BY A LICENSED SUB-CONTRACTOR. Albertville, MN 1/4" = 1'-0" Store #14011 6495 Labeaux Ave, NE. Demolition Floor Plan Project Description: N 12.1 CONTRACTOR SHALL COORDINATE SCOPE OF DEMOLITION WORK WITH PROPOSED WORK. DO NOT DEMOLISH BEYOND THE SCOPE OF WORK TO BE PERFORMED. CONTRACTOR IS RESPONSIBLE TO REPAIR OR REPLACE ANY ITEMS DAMAGED WHICH ARE NOT PART OF THE SCOPE OF WORK SHOWN ON THESE DRAWINGS AT THE CONTRACTORS EXPENSE. Burger King 11.1 ANY ASBESTOS ENCOUNTERED DURING CONSTRUCTION SHALL BE REMOVED OR ENCAPSULATED BY A LICENSED ASBESTOS CONTRACTOR IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. RAN # / ST-000 -- 16. REPLACE TOILETS, URINALS AND DOORS OF RESTROOMS. 8. GC TO REMOVE ALL STICKERS ON THE GLASS Month 00, 0000 D-1.0 Demolition Floor Plan Demo Ceiling Legend 2' X 2' CEILING GRID TO BE REMOVED EXIT LIGHT TO BE REMOVED TRACK & LIGHT FIXTURE TO BE REMOVED 2 X 4 FLUORESCENT NIGHT / EMERGENCY LAY-IN FIXTURE TO BE REMOVED 2 X 4 FLUORESCENT LAY-IN FIXTURE TO BE REMOVED R 'R' INDICATES FIXTURE TO BE RELOCATED, SEE CEILING PLAN SHEET A-3.0 FOR NEW LOCATION WALL MOUNTED SCONCE TO BE REMOVED architecture.us phone: 1.888.666.0931 WALL WASH SPOT LIGHT TO BE REMOVED FLUORESCENT STRIP LIGHTS TO BE REMOVED Project Team: CEILING MOUNTED LIGHT FIXTURE TO BE REMOVED RECESSED CAN LIGHT TO BE REMOVED PENDANT LIGHT FIXTURE TO BE REMOVED WALL MOUNTED EMERGENCY LIGHT TO BE REMOVED GYPSUM BOARD CEILING TO BE REMOVED EXISTING GYPSUM BOARD CEILING TO REMAIN 2' X 4' CEILING GRID TO BE REMOVED EXHAUST FAN GRILLE TO BE REMOVED RETURN AIR GRILLE TO BE REMOVED R 'R' INDICATES DIFFUSER / GRILLE TO BE RELOCATED, SEE CEILING PLAN SHEET A-3.0 FOR NEW LOCATION SUPPLY AIR DIFFUSER TO BE REMOVED Demo Ceiling Keynotes 1. EXISTING MANSARD ROOF OVERHANG TO BE REMOVED. 2. EXISTING MANSARD LIGHTING TO BE REMOVED, TYPICAL. 3. REMOVE EXISTING CEILING AND GRID. 4. REPLACE OR PAINT EXISTING HVAC DIFFUSERS AND SPEAKERS. VERIFY W/OWNER. General Notes A. SEE DIVISION 2 - DEMOLITION OF THE SPECIFICATIONS ON SHEET D-1.0. B. ITEMS SHOWN ON THE DEMO CEILING PLAN WITH DASHED LINES INDICATES IT IS TO BE REMOVED OR RELOCATED. ITEMS SHOWN WITH SOLID LINES INDICATES AN ITEM TO REMAIN. ITEMS SHOWN WITH 'E' ARE EXISTING AND TO REMAIN. C. EXISTING SUPPLY AIR DIFFUSERS & RETURN AIR GRILLES TO BE REUSED IF POSSIBLE. Albertville, MN 1/4" = 1'-0" Store #14011 6495 Labeaux Ave, NE. Demolition Ceiling Plan Burger King N Project Description: Revisions RAN # / ST-000 -Month 00, 0000 D-2.0 Demolition Ceiling Plan 2 A-6.0 architecture.us 106A phone: 1.888.666.0931 Project Team: F1E 9 F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F1E A-2.1 F5A F5A F1E F5A H F4A H F4A 104 FMCT310C 106B H F4A H F4A H F4B H F4A H F4B FMCT310C H F4A H F4A 102 105 H F4B H F4A H F4A H F4B 5'-0" MANEUVERING ZONE H F4A FMCT310C FCE1T2001 FCE1T2001 F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A F5A GRAIN 5'-0" MANEUVERING ZONE F5A F5A F5A F5A F5A F5A FCE1T2001 F5A 8 7 A-6.2 A-6.2 F5A Revisions Floor Plan 1/4" = 1'-0" Floor Plan Keynotes 1. 34" A.F.F. SERVICE COUNTER ON LOW WALL, SEE DETAILS ON SHEET A-7.1. COORDINATE COUNTERTOP/FINISHES INSTALLATION RESPONSIBILITIES WITH THE DECOR SUPPLIER. FRONT EDGE OF COUNTERTOP TO ALIGN WITH FRONT OF BULKHEAD ABOVE. MAX. HEIGHT OF COUNTERTOP IS 34" A.F.F. 2. DASHED LINE INDICATES LINE OF AWNING / CANOPY ABOVE. General Notes A. CONTRACTOR IS RESPONSIBLE FOR MOVING EXISTING BEVERAGE COUNTER BACK TO ORIGINAL LOCATION AFTER INSTALLATION OF INTERIOR FINISHES. B. PROVIDE CLASS K FIRE EXTINGUISHER (MIN. 1.5 GAL.) AT KITCHEN AREA IF NOT EXISTING, VERIFY SIZE WITH FIRE MARSHALL. LOCATE WITHIN 30' OF VENTILATION HOOD. GC TO VERIFY THAT NEWLY INSTALLED OR EXISTING FIRE EXTINGUISHER ARE LOCATED PER LOCAL CODE REQUIREMENTS. 3. GC TO INSTALL NEW ROLL-UP WINDOW SHADES -CHAIN CONTROLLED ON THE CAMERAS ARE IN WORKING ORDER. D. GC TO REPLACE THE CLOSING HANDLE ON THE EXISTING ROOF HATCH ADD A NEW SOFFIT, NEW CEILING TILE AND GRID (CLEANABLE), NEW LED LIGHTING . 5. EXISTING ELECTRICAL PANEL(S) LOCATION. 6. FOR NEW MACHINE (LANCER 4500) E. GC TO INSTALL NEW DIGITAL THERMOSTATS F. GC IS RESPONSIBLE FOR PROVIDING NEW SECURITY LIGHTING AND EXIT SIGNS G. INSTALL NEW CONVENIENT OUTLETS AROUND THE PERIMETER OF THE DINING ROOM Albertville, MN F5A Store #14011 6495 Labeaux Ave, NE. F5A Project Description: N F5A Burger King F5A 7. PROVIDE DECAL INDICATING ACCESSIBLE ENTRY, SEE DETAIL A15 ON SHEET A-7.0 . 8. TV LOCATION, PROVIDE SUPPORT FOR T.V. MOUNTING BRACKET. VERIFY SIZE AND EXACT LOCATION OF T.V. WITH DECOR SUPPLIER. T.V. PROVIDED BY TENANT. 9. INSTALL ALL NEW METAL CORNER GUARDS, REFER TO DETAIL A8 ON SHEET A-7.0. 10. GC TO REMOVE AND REPLACE DOOR AT THE EXISTING STORAGE CLOSET LOCATED OUTSIDE OF THE RESTROOMS. REUSE THE EXISTING DOOR HARDWARE AND REPAINT THE DOOR FRAME. H. GC TO REMOVE THE EXISTING DAMAGED BOLT AND REPLACE WITH A NEW BOLT ON THIRD STAIR AT ROOF HATCH ACCESS LADDER. RAN # / ST-000 i. REUSE THE EXISTING EMERGENCY EXIT HARDWARE ON DOORS. GC TO VERIFY THAT IT IS IN PROPER WORKING CONDITION AND REPAIR OR REPLACED IF DAMAGED. -Month 00, 0000 A-2.0 Floor Plan Restroom Accessories MEN'S RESTROOM ACCENT TILE GRAB BAR: BOBRICK 250 LBF. MINIMUM - RE-USE EXISTING GRAB BARS 33" MIN. TO 36" MAX. HEIGHT TO THE TOP OF THE GRIPPING SURFACE. PROVIDE THE REQUIRED QUANTITY AND LENGTH AS INDICATED ON THE DRAWINGS OR AS REQUIRED BY THE GOVERNING CODE. THE BAR SHALL BE 1-1/2" IN DIAMETER AND MOUNTED WITH 1-1/2" CLEARANCE FROM THE WALL. NOTE: MIRROR TO BE LOCATED AS DIRECTED BY BRYAN ANDERSON ACCENT TILE NOTE: ALL GRAB BARS SHALL BE CAPABLE OF SUPPORTING A 250 LB. CONCENTRATED LOAD PER IBC 1607.7.2. PROVIDE BLOCKING IN WALL AS NECESSARY. WALL MOUNTED SOAP DISPENSER AND HAND SANITIZER DISPENSER (36" MAX. HEIGHT) G.C. PROVIDE AND INSTALL NOTE: SOAP AND HAND SANITIZER DISPENSERS TO BE PROVIDED AT EACH KITCHEN HANDSINK. MIRROR: BOTTOM OF REFLECTIVE SURFACE AT 40" MAXIMUM HEIGHT. G.C. PROVIDE AND INSTALL. MODEL B-165-1836 (18"x36") STAINLESS STEEL CHANNEL FRAME MIRROR WITH THEFT RESISTANT SCREWS BY BOBRICK OR APPROVED EQUIVALENT. VERIFY PLACEMENT WITH OWNER PRIOR TO INSTALL. architecture.us phone: 1.888.666.0931 TOILET PAPER HOLDER: G.C. PROVIDE AND INSTALL 9" TWIN JUMBO MODEL #58250 BY NORTH AMERICAN CORPORATION. Project Team: XCELERATE WALL MOUNTED HAND DRYER WITH CORIAN SANDLEWOOD DRIP PANELS BELOW PANEL. G.C. IS TO PROVIDE AND INSTALL BABY CHANGING STATION: KOALA KARE #KB100-01 (HORIZONTAL) WALL MOUNTED WITH STAINLESS STEEL. G.C. PROVIDE AND INSTALL SANITARY BED LINERS FOR BABY CHANGING STATION: KOALA KARE #KB150-99 NOTE: CHANGING STATION OPTION TO COMPLY WITH ALL ACCESSIBILITY REQUIREMENTS. BACK LEFT 4 Elevation RIGHT 3 SCALE: 1/2" = 1'-0" Elevation SCALE: 1/2" = 1'-0" 2 COAT HOOK: BOBRICK MODEL B-6717 TO BE MOUNTED ON INSIDE OF EACH RESTROOM DOOR FOR SINGLE OCCUPANT RESTROOMS AND EACH RESTROOM STALL DOOR FOR MULTIPLE OCCUPANCY RESTROOMS. MOUNT AT 38"-40" A.F.F. FOR ADA ACCESSIBLE LOCATIONS AND AT 48" A.F.F. MAXIMUM FOR NON-ADA ACCESSIBLE LOCATIONS. G.C. PROVIDE AND INSTALL Elevation 1 SCALE: 1/2" = 1'-0" Elevation SANITARY NAPKIN DISPOSAL: BOBRICK MODEL B-254 (WOMEN'S TOILETS ONLY). G.C. PROVIDE AND INSTALL SCALE: 1/2" = 1'-0" BLACK HD PE PARTITIONS SUPPLIED AND INSTALLED BY G.C. WOMEN'S RESTROOM ACCENT TILE ACCENT TILE ACCENT TILE NOTE: MIRROR TO BE LOCATED AS DIRECTED BY BRYAN ANDERSON ACCENT TILE Keynotes 1. EXISTING FLOOR DRAIN, CONTRACTOR TO REPLACE IF NECESSARY. 2. TILE WALL FINISH, TYPICAL. REFER TO INTERIOR DECOR DRAWINGS FOR SPECIFICATIONS. 3. RESTROOM SIGNAGE, SEE DETAIL A8 ON SHEET A-7.0. 4. INSTALL A NEW TOILET 5. INSTALL A NEW SINK - NEW SINK TO BE INSTALLED PER ADA REGULATIONS. 6. INSTALL A NEW URINAL 7. INSTALL A RECESSED STAINLESS STEEL BABY CHANGING TABLE. SCALE: 1/2" = 1'-0" 6 5 SCALE: 1/2" = 1'-0" 10. NEW FRAME AT 4327 Elevation Revisions 11. INSTALL NEW LED LIGHTING SCALE: 1/2" = 1'-0" 12. INSTALL NEW TILE ON WALLS 13. REUSE GRAB BARS 14. EXISTING MIRROR TO REMAIN. 16. GC TO PROVIDE SOAP AND HAND SANITIZER DISPENSERS. 1 4 A-2.1 17. GC TO PROVIDE SS FEMININE DISPOSAL BOXES AND SS TOILET PAPER HOLDERS. 2 3 General Notes A. FOR INTERIOR FINISHES REFER TO INTERIOR DECOR DRAWINGS. 5 8 A-2.1 B. PLUMBING FIXTURES TO BE PROVIDED BY THE GENERAL CONTRACTOR. 6 7 C. ALL PLUMBING FIXTURES, FAUCETS AND ACCESSORIES TO BE ADA COMPLIANT. D. ALL EXPOSED PIPING UNDER LAVATORIES TO BE INSULATED TO PROTECT FROM CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. Albertville, MN 7 Elevation 9. INSTALL A NEW DOOR AND HARDWARE Store #14011 6495 Labeaux Ave, NE. SCALE: 1/2" = 1'-0" Elevation RIGHT Burger King 8 Elevation BACK LEFT Project Description: FRONT 8. INSTALL A NEW XCELERATE HAND DRYER OVER A NEW CORIAN PANEL (SANDALWOOD) RAN # / ST-000 -Month 00, 0000 9 Enlarged Restroom Floor Plan 1/2" = 1'-0" A-2.1 Enlarged Plan / Int. Elev. Ceiling Legend 2' X 2' CEILING GRID WITH LAY-IN PANELS. SEE DETAIL A7, SHEET A7.0 EXIT LIGHT W/ BATTERY PACK 2 X 4 FLUORESCENT NIGHT / EMERGENCY LAY-IN FIXTURE EXIT/ EMERGENCY COMBO LIGHT FIXTURE 2 X 4 FLUORESCENT LAY-IN FIXTURE T LIGHT FIXTURE TYPE, REFER TO LIGHTING SCHEDULE FOR FIXTURE TYPE 'E' = EXISTING, 'R' = RELOCATED PENDANT LIGHT FIXTURE architecture.us phone: 1.888.666.0931 WALL WASH LIGHT FIXTURE 1x4 FLUORESCENT LIGHT FIXTURE Project Team: DECORATIVE GLASS PENDANT (6) LIGHT FIXTURE OPEN TO STRUCTURE EXISTING GYPSUM BOARD CEILING RECESSED CAN LIGHT SURFACE MOUNTED CYLINDER LIGHT WALL MOUNTED EMERGENCY LIGHT INDICATES CEILING / HEADER HEIGHT 5/8" GYPSUM BOARD CEILING / SOFFIT SEE DETAIL A11, SHEET A-7.0 5/8" GYPSUM BOARD CEILING W/ SOUND BATT INSULATION. SEE DETAIL A11, SHEET A7.0 EXHAUST FAN GRILLE RETURN AIR GRILLE 'E' = EXISTING, 'R' = RELOCATED 2' X 4' CEILING GRID WITH LAY-IN PANELS. SEE DETAIL A7, SHEET A7.0 SUPPLY AIR DIFFUSER 'E' = EXISTING, 'R' = RELOCATED WALL WASH SPOT CAN LIGHT SINGLE DECORATIVE GLASS PENDANT EXTERIOR WALL MOUNTED SCONCE 12x12 RECESSED SOFFIT LIGHT 4' FLUORESCENT UNDER CANOPY LIGHT WALL MOUNTED SECURITY LIGHT P 4' GOOSENECK FLUORESCENT LIGHT FIXTURE P Ceiling Plan Keynotes 1. PREFABRICATED METAL AWNING. LIGHTING MAY BE INCLUDED, VERIFY WITH OWNER. 2. MENU BOARD, ATTACH TO EXISTING HEADER. THE BOTTOM OF MENU BOARD SHALL NOT BE BELOW THE BOTTOM OF HEADER. 3. GYP. BOARD HEADER BETWEEN SERVING & DINING ROOM AT 8'-10" A.F.F., REFER TO INTERIOR DECOR DRAWINGS FOR FINISH. THE FRONT EDGE (DINING ROOM SIDE) OF HEADER IS TO LINE UP WITH THE FRONT EDGE OF COUNTERTOP BELOW. 4. EXISTING EXHAUST HOOD TO REMAIN. Revisions 5. REMOVE EXISTING CEILING AND GRID AND REPLACE WITH NEW BLACK GRID AND BLACK CEILING TILES IN THE DINING ROOM AND PLAY LAND AREAS KITCHEN 7. GC TO INSTALL A NEW DRYWALL CEILING IN THE FOYER. 8. GC TO INSTALL NEW LED LIGHTING CAN LIGHTING IN THE FOYER 9. BUILD A NEW SOFFIT AROUND THE EXPOSED DUCT WORK IN THE PLAY LAND. ADD NEW CAN LIGHTING IN THE SOFFIT. SEE DETAIL AXX ON SHEET A-7.0. B. THE REFERENCE HEIGHTS INDICATED ON PLAN ARE FROM APPROXIMATE FINISH FLOOR (A.F.F.). Ceiling Plan 1/4" = 1'-0" D. THE CONTRACTOR IS RESPONSIBLE FOR EXTENDING ANY EXISTING MECHANICAL DUCT WORK TO THE NEW CEILING HEIGHT AND TO RELOCATED DIFFUSER/GRILLE LOCATIONS. E. SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLES ARE TO BE PAINTED TO MATCH CEILING. F. ALL EXIT SIGNS AND EMERGENCY LIGHTING SHALL BE REPLACED, SUPPLIED AND INSTALLED BY GC, UNLESS NOTED OTHERWISE. G. THE CONTRACTOR SHALL COORDINATE DINING ROOM LIGHTING WITH THE APPROVED INTERIOR DECOR DRAWINGS. H. FOR OPEN DINING ROOM CEILING OPTIONS, LIGHT FIXTURES ARE TO BE SUPPORTED FROM EXPOSED ROOF TRUSSES. USE 2x4 BETWEEN BOTTOM CORDS FOR SURFACE MOUNTED FIXTURES. Project Description: N C. ALL DIMENSIONS SHOWN ON THE CEILING PLAN ARE FROM FACE OF WALL FINISH UNLESS NOTED OTHERWISE. / PAINT IF IN GOOD CONDITION. RAN # / ST-000 J. ADD ADDITIONAL LIGHTS IN THE WALK-IN COOLERS. -- K. PROVIDE ALL NEW LED LIGHTING IN THE DINING ROOM AND PLAY LAND Month 00, 0000 L. REPLACE OR PAINT EXISTING HVAC DIFFUSERS AND SPEAKERS. GC TO CONFIRM THAT ALL MATCH EXISTING. M. GENERAL CONTRACTOR TO BALANCE THE EXISTING HVAC SYSTEM. Albertville, MN A. ALL FIXTURES SHALL BE LOCATED IN CENTER OF CEILING TILES UNLESS OTHERWISE NOTED. Store #14011 6495 Labeaux Ave, NE. General Notes Burger King 10. CONSTRUCT A NEW SOFFIT ABOVE THE ORDER COUNTER. A-3.0 Ceiling Plan Roof Legend INDICATES DIRECTION OF ROOF SLOPE Keynotes 1. E OP FT SL /4" / N.1 MI PE / FT O " SL 1/4 . IN M E OP FT SL /4" / N.1 MI E T MI SLO P N. O /F 1/4 PE SL /4" "/ 1 FT N. I M PROVIDE 45 MIL TPO SINGLE-PLY ROOFING SYSTEM OVER PLYWOOD ROOF DECK OVER PRE-FABRICATED WOOD TRUSSES, TYPICAL. REFERENCE DETAIL 1 ON A9.2. 2. PROVIDE ROOF ACCESS HATCH. REFERENCE DETAIL 15 ON A9.2. 3. INDICATED METAL CANOPY BELOW. REFERENCE EXTERIOR ELEVATIONS. 4. PROVIDE ROOF TOP EXHAUST FAN. REFER TO MECHANICAL DRAWINGS. 5. PROVIDE ROOF DRAIN AND OVERFLOW LEADERS IN TRUSS SPACE THEN DOWN WALL TO DAYLIGHT. 6. PROVIDE ROOF CRICKET REFERENCE DETAIL 3 ON A9.2 7. PROVIDE ROOF DRAIN AND OVERFLOW DRAIN. REFERENCE DETAIL 5 ON A9.2. 8. PROVIDE ROOF TOP MECHANICAL UNIT. REFERENCE MECHANICAL DOCUMENTS. 9. PROVIDE ROOF TOP EXHAUST FAN. POSITION FAN OVER KITCHEN HOODS SO DUCT BENDS ARE NOT REQUIRED. REFERENCE MECHANICAL DRAWINGS. 10. INDICATES 10'-0" CLEARING RADIUS. MAINTAIN CLEARANCE FOR EQUIPMENT WITH OUTSIDE AIR INTAKE INTO THE BUILDING. 11. COORDINATE INSTALLATION OF REMOTE COMPRESSOR/CONDENSER.FOR ICE MACHINE OR WALK-IN COOLER/FREEZER. PROVIDE PITCH PANS AS REQUIRED. COORDINATE EXACT LOCATION WITH MANUFACTURER AND EQUIPMENT INSTALLER. 12. PROVIDE WALKING PADS OVER ROOFING SYSTEM SPACED 4 FEET APART. TYPICAL. 13. PROVIDE ROOFING SYSTEM OVER PLYWOOD ROOF DECK OVER ABOVE ROOF DECK STRUCTURAL BRACING. architecture.us phone: 1.888.666.0931 Project Team: General Notes A. THE ROOF STRUCTURE SHALL NOT BE USED FOR STOCKPILING OF EQUIPMENT OR MATERIALS UNLESS APPROVED BY THE ARCHITECT, STRUCTURAL ENGINEER AND THE JOIST MANUFACTURER. B. C. COORDINATE ROOF ELEVATIONS WITH STRUCTURAL DRAWINGS. PROVIDE ROOFING SYSTEM AND ITS ACCESSORIES WITH A MINIMUN FIFTEEN (15) YEAR GUARANTY. COORDINATE AND VERIFY LOCATIONS OF ROOF PENETRATIONS. COORDINATE TRUSS DESIGN LOCATIONS SO EXHAUST DUCTS FOR FRYERS AND BROILER ARE STRAIGHT WITH NO BENDS. GENERAL CONTRACTOR TO VERIFY LOCATION OF ALL ROOFTOP EQUIPMENT PRIOR TO INSTALLATION OF THE NEW ROOF. D. E. F. PE / FT O " SL 1/4 . IN M Albertville, MN 1/4" = 1'-0" Store #14011 6495 Labeaux Ave, NE. Roof Plan Project Description: N Burger King Revisions RAN # / ST-000 -Month 00, 0000 A-3.1 Roof Plan Architectural Specifications 101 DINING ROOM 102 SERVING AREA 103 KITCHEN 104 MEN'S RESTROOM 105 WOMEN'S RESTROOM 106 VESTIBULE 107 DRIVE THRU 108 UTILITY 109 OFFICE 110 OVERFLOW DINING 111 STORAGE - - - - - - - - EAST WEST PATCH / REPAIR / PAINT DIVISION 8 DIVISION 10 DOOR AND FRAMES SPECIALTIES 1.1 ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 1.1 GRAB BARS: AS MANUFACTURED BY FRANKLIN BRASS. ALL GRAB BARS MUST BE INSTALLED SO AS TO RESIST A VERTICAL LOAD OF 300 LBS. MINIMUM. GB1: 36" STAINLESS STEEL #6436 GB2: 48" STAINLESS STEEL #6448 2.1 MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED. 3.1 ITEM 1 NEED NOT APPLY TO THE FRONT DOOR OF A PLACE OF BUSINESS AS LONG AS A SIGN IS PLACED ABOVE THE DOOR IN 2" BLOCK LETTERS WITH CONTRASTING BACKGROUND THAT READS, "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED ". NORTH EXISTING GYP. BOARD EXISTING WALK-IN CEILING INDICATES WHERE WALL FINISH OCCURS GYP. BOARD,PAINT SUSP. GRID/ACOUST. TILE (ACT-2) SUSP. GRID/ACOUST. TILE (ACT-1) PATCH / REPAIR / REPLACE AS NEEDED EXISTING FRP - FULL WALL HEIGHT EXISTING WALK-IN WALLS FRP - FULL WALL HEIGHT TILE - FULL WALL HEIGHT PER INTERIOR DECOR DRAWINGS REPAIR / REPLACE AS NEEDED EXIST. COVE TILE 6"H COVE TILE EXISTING CONCRETE TILE SEE DIVISION 9 OF THE SPECIFICATIONS, CONTAINING IMPORTANT INFORMATION RELATING TO BUILDING CODES, CITY ORDINANCES, MATERIALS AND METHODS. EXISTING TILE Note REPAIR / REPLACE AS NEEDED Room Finish Schedule Architectural Specifications SOUTH (PLAN ORIENTATION) WINDOWS AND GLASS 1.1 ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARDS SET FORTH IN SECTION 2406 OF THE INTERNATIONAL BUILDING CODE. 2.1 GLASS: MATCH EXISTING THICKNESS, DESIGN AND FEATURES OF EXISTING GLASS. OTHERWISE USE REQUIRED BY NOTE 1 ABOVE. 1 4" FLOAT OR TEMPERED AS DIVISION 9 -- 2.1 TOILET PARTITIONS: BAKED ENAMEL FINISH, FLOOR SUPPORTED, METAL PARTITIONS AS MANUFACTURED BY: FINISHES 1.1 REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE TO REMAIN. REPAIR TO "LIKE NEW" CONDITION, MATCHING ALL NEW WORK IN QUALITY, COLOR AND MATERIALS. 2.1 SMOKE AND FLAME SPREAD FOR INTERIOR FINISHES FOR WALLS AND CEILING TO BE PER ASTM E84 AND IBC 803. FOR A-2 OCCUPANCIES IN A SPRINKLERED SUITE: EXIT ENCLOSURES AND EXIT PASSAGEWAYS CLASS B (FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450) CORRIDORS CLASS B (FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450) ROOMS AND ENCLOSED SPACES CLASS C (FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450) 3.1 WALL FINISH NOTES a. GYP. BOARD FINISH LEVELS (FINISH PANELS TO LEVELS INDICATED BELOW PER ASTM C 840): AT NEW AND EXISTING WALLS LEVEL 1 FINISH: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHERE INDICATED. a. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND. SURFACE SHALL BE FREE OF EXCESS JOINT COMPOUND. TOOL MARKS AND RIDGES SHALL BE ACCEPTABLE. GENERAL PARTITIONS MFG.,CORP TEL: 814-833-1154 FAX: 814-838-3473 PARTITION MANUFACTURERS OF AMERICA, INC. TEL: 516-623-0222 FAX: 516-623-5809 ----------------------------------------------------------------------------------------------------------------------------------------------3.1 TOILET ACCESSORIES: ALL ITEMS AS MANUFACTURED BY BOBRICK- CONTURA SERIES a. PROVIDE ONE EACH AT EACH SINGLE USE TOILET: - TOILET PAPER DISPENSER, #B-4288 - TOILET SEAT COVER DISPENSER, #B-4221 - SOAP DISPENSER, #B-4112 - WASTE RECEPTACLE, #B-277 - PAPER TOWEL DISPENSER, #B-4262 - MIRROR 24" X 36", #B-165 2436 - SANITARY NAPKIN DISPOSAL, #B-270 (WOMEN'S SINGLE USE TOILET ONLY) ----------------------------------------------------------------------------------------------------------------------------------------------3.1 TOILET ACCESSORIES: ALL ITEMS AS MANUFACTURED BY BOBRICK- MATRIX SERIES architecture.us phone: 1.888.666.0931 Project Team: a. PROVIDE ONE EACH AT EACH SINGLE USE TOILET: - TOILET PAPER DISPENSER, #B-5288 - TOILET SEAT COVER DISPENSER, #B-5221 - SOAP DISPENSER, #B-5050 - WASTE RECEPTACLE, #B-5277 - PAPER TOWEL DISPENSER, #B-5262 - MIRROR 24" X 36", #B-165 2436 - SANITARY NAPKIN DISPOSAL, #B-5270 (WOMEN'S SINGLE USE TOILET ONLY) ----------------------------------------------------------------------------------------------------------------------------------------------4.1 FIRE EXTINGUISHERS: AS REQUIRED BY LOCAL JURISDICTION. b. WHERE GLASS MESH TAPE IS USED, THE GLASS MESH TAPE SHALL BE ADHERED OR ATTACHED TO THE WALL AND HAVE ONE COAT OF SETTING TYPE JOINT COMPOUND OVER THE SURFACE OF THE JOINT. General Notes Remarks A. FLOORS IN RESTROOMS SHALL HAVE A SMOOTH, HARD NONABSORBENT SURFACE SUCH AS PORTLAND CEMENT, CERAMIC TILE, CONCRETE, OR OTHER APPROVED MATERIAL WHICH EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES. 1. NONE. FURNISHINGS LEVEL 2 FINISH: PANELS THAT ARE SUBSTRATE FOR TILE. B. PROVIDED WATER-RESISTANT GYPSUM BOARD, GREEN BOARD, OR OTHER APPROVED MATERIAL ON THE WALLS IN RESTROOMS. DIVISION 12 a. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND SHALL BE IMMEDIATELY WIPED WITH A JOINT KNIFE OR TROWEL LEAVING A THIN COATING OF JOINT COMPOUND OVER ALL JOINTS AND INTERIOR ANGLES. FASTENER HEADS AND ACCESSORIES SHALL BE COVERED WITH A COAT OF JOINT COMPOUND. SURFACE SHALL BE FREE OF EXCESS JOINT COMPOUND. TOOL MARKS AND RIDGES ARE ACCEPTABLE. CASEWORK 1.1 DETAILED CASEWORK DRAWINGS ARE NOT A PART OF THE SCOPE OF THESE DOCUMENTS. CONTRACTOR SHALL WORK WITH A CASEWORK SUBCONTRACTOR AND THE OWNER/TENANT TO DETERMINE THE LAYOUT AND QUANTITY OF ALL CASEWORK DIAGRAMMATICALLY SHOWN ON THE FLOOR PLANS. b. JOINT COMPOUND APPLIED OVER THE BODY OF THE TAPE AT THE TIME OF TAPE EMBEDMENT SHALL BE CONSIDERED A SEPARATE COAT OF JOINT COMPOUND AND SHALL SATISFY THE CONDITIONS OF THIS LEVEL. 2.1 PROVIDE CASEWORK WITH ALL NECESSARY HARDWARE, HINGES AND PULLS. LEVEL 4 FINISH: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW, UNLESS OTHERWISE INDICATED. COLOR/ FINISH REMARKS PAINT FINISH REFER TO ID DRAWINGS REFER TO ID DRAWINGS REFER TO ID DRAWINGS - - - - - - TILE REFER TO ID DRAWINGS REFER TO ID DRAWINGS REFER TO ID DRAWINGS - - - - - - FRP REFER TO ID DRAWINGS REFER TO ID DRAWINGS REFER TO ID DRAWINGS - - - - - - TILE REFER TO ID DRAWINGS REFER TO ID DRAWINGS REFER TO ID DRAWINGS - - - - - - TILE REFER TO ID DRAWINGS REFER TO ID DRAWINGS REFER TO ID DRAWINGS - - - COVE BASE - - Wall Finishes Floor Finishes Bases b. FINISHING COMPOUND AND ALL-PURPOSE COMPOUND SHALL BE APPLIED WITH TOOLS OF SUFFICIENT WIDTH TO SHALL BE DRAWN DOWN TO A LEVEL PLANE. AFTER THE COMPOUND HAS DRIED, THE SURFACE SHALL BE SANDED (APPROVED PROTECTIVE RESPIRATORS SHALL BE WORN WHEN MIXING DRY COMPOUND OR SANDING) OR WIPED WITH A DAMPENED SPONGE TO ELIMINATE HIGH SPOTS AND EXCESSIVE COMPOUND. LEVEL 5 FINISH: AT PANEL SURFACES THAT WILL RECEIVE GRAPHICS OR WALL COVERING a. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND SHALL BE IMMEDIATELY WIPED WITH A JOINT KNIFE OR TROWEL LEAVING A THIN COATING OF JOINT COMPOUND OVER ALL JOINTS AND INTERIOR ANGLES AS DESCRIBED FOR LEVEL 2. TWO SEPARATE COATS OF JOINT COMPOUND SHALL BE APPLIED OVER ALL FLAT JOINTS. ONE SEPARATE COAT OF JOINT COMPOUND SHALL BE APPLIED OVER INTERIOR ANGLES. FASTENER HEADS AND ACCESSORIES SHALL BE COVERED WITH THREE SEPARATE COATS OF JOINT COMPOUND. A THIN SKIM COAT OF JOINT COMPOUND SHALL BE TROWEL-APPLIED TO THE ENTIRE SURFACE. EXCESS COMPOUND IS IMMEDIATELY SHEARED OFF, LEAVING A FILM OF SKIM COATING COMPOUND COMPLETELY COVERING THE PAPER. AS AN ALTERNATE TO A SKIM COAT, A MATERIAL MANUFACTURED ESPECIALLY FOR THIS PURPOSE SHALL BE APPLIED. THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES (COATS OF NON-SETTING TYPE COMPOUNDS SHALL BE THOROUGHLY DRY BEFORE SANDING OR THE APPLICATION OF ADDITIONAL COATS). Revisions b. PRIMER AND PAINT PER THE ROOM FINISH SCHEDULE. Ceilings c. ALL WALLS SHALL HAVE SQUARE CORNER BEAD, TYP. ACT-1 ARMSTRONG PRELUDE (15/16") GRID & TILE COLOR PER - (FRONT OF HOUSE) FINE FISSURED 24" X 24" ID DRAWINGS - d. ALL GYP BOARD SOFFITS SHALL HAVE SQUARE CORNER BEAD, TYP. ACT-2 ARMSTRONG PRELUDE (15/16") PANEL: WHITE - 5.1 FLOOR FINISH NOTES: (BACK OF HOUSE) VINYL CLAD TILE 24" X 48" GRID: WHITE a. ALL FLOOR TO RECEIVE CERAMIC TILE SHALL HAVE A MAXIMUM OF Windows and Glass WINDOWS MATCH BUILDING METAL COLOR TO BE CHOSEN FIXED GLAZING UNLESS - STANDARD OR EQUAL - BY TENANT OTHERWISE NOTED ON PLANS WINDOWS MATCH BUILDING ANODIZED ALUMINUM FINISH TO MATCH FIXED GLAZING UNLESS - STANDARD OR EQUAL EXISTING BUILDING OTHERWISE NOTED ON PLANS 1 8" PER FOOT SLOPE ACROSS PER 10'X10' AREA. b. ALL FLOOR EXPANSION JOINTS, PATCHES AND IMPERFECTIONS SHALL BE PREPARED WITH EPOXY TYPE FLOOR LEVELER AND/OR FILLER PRIOR TO FINAL FLOOR COVERING INSTALLATION. c. ALL FLOOR FINISHES ARE AS INDICATED ON THE ROOM FINISH SCHEDULE. WITH FINAL COLOR AND STYLE SELECTIONS BY OWNER/TENANT. d. CARPET AND INTERIOR FLOOR FINISHES COMPRISED OF FIBERS IN VERTICAL EXITS, EXIT PASSAGEWAYS AND EXIT ACCESS CORRIDORS SHALL NOT BE LESS THEN CLASS II IN ACCORDANCE WITH NFPA 253. IN ALL OTHER AREAS THE INTERIOR FLOOR FINISHES SHALL COMPLY WITH THE DOC FF-1 "PILL TEST"(CPSC 16 CFR, PART 1630). IN A SPRINKLERED BUILDING, MATERIALS COMPLYING WITH THE "PILL TEST" MAY BE USED WHERE CLASS II ARE REQUIRED. e. TRANSITIONS BETWEEN MATERIALS TO BE WITH SLEUTER TRIM OR EQUIVALENT. MAXIMUM 1/8" TOLERANCE BETWEEN ELEVATIONS OF FINISHED MATERIALS. Albertville, MN STYLE Store #14011 6495 Labeaux Ave, NE. MANUFACTURER & MODEL # Burger King D. REFER TO INTERIOR DECOR DRAWINGS FOR COMPLETE FINISH SPECIFICATIONS. a. ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND SHALL BE IMMEDIATELY WIPED WITH A JOINT KNIFE OR TROWEL LEAVING A THIN COATING OF JOINT COMPOUND OVER ALL JOINTS AND INTERIOR ANGLES AS DESCRIBED FOR LEVEL 2. TWO SEPARATE COATS OF JOINT COMPOUND SHALL BE APPLIED OVER ALL FLAT JOINTS. ONE SEPARATE COAT OF JOINT COMPOUND SHALL BE APPLIED OVER INTERIOR ANGLES. FASTENER HEADS AND ACCESSORIES SHALL BE COVERED WITH THREE SEPARATE COATS OF JOINT COMPOUND. ALL JOINT COMPOUNDS SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES. Project Description: C. WALLS IN RESTROOMS WITHIN 2 FEET OF THE FRONT AND SIDES OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD NONABSORBENT SURFACE TO A HEIGHT OF 4 FEET. RAN # / ST-000 -Month 00, 0000 A-4.0 Room & Door Schedules Door Types Door Schedule Door Opening Details Door Type 'A' Door Type 'B' EXISTING DOOR TYPE EXISTING HARDWARE HARDWARE GROUP 90 MINUTE 45 MINUTE 20 MINUTE EXISTING HOLLOW METAL SOLID CORE HPL ALUMINUM 3'-2" X 7'-0" X 1-3/4" 2'-0" X 6'-8" X 1-3/4" 3'-0" X 6'-8" X 1-3/4" 3'-0" X 7'-0" X 1-3/4" PAIR EXISTING ALUMINUM SEE DIVISION 8 OF THE SPECIFICATIONS, CONTAINING IMPORTANT INFORMATION RELATING TO BUILDING CODES, CITY ORDINANCES, MATERIALS AND METHODS. HOLLOW METAL Note architecture.us A 102 CLOSET A A 104 MEN'S RESTROOM B B 1 105 WOMEN'S RESTROOM B B 1 106A VESTIBULE - EXTERIOR E F 106B VESTIBULE - INTERIOR F F General Notes Remarks A. EXISTING DOORS & FRAMES THAT WILL REMAIN ARE TO BE PROTECTED DURING CONSTRUCTION. 1. UNDERCUT DOOR 1" FOR AIR FLOW WHEN HVAC SUPPLY IS NOT PROVIDED. phone: 1.888.666.0931 Head Detail SCALE: 3" = 1'-0" Project Team: B. EXISTING ALUMINUM DOORS & FRAMES TO BE CLEANED TO "LIKE NEW" CONDITION. B. EXISTING HOLLOW METAL DOORS & FRAMES TO BE PAINTED TO MATCH WALL. C. EXISTING LAMINATE DOORS REPLACED. MANUFACTURER & MODEL # STYLE COLOR/ FINISH REMARKS B Jamb Detail SCALE: 3" = 1'-0" Interior Doors and Frames Door Type 'F' INTERIOR MATCH BURGER KING STANDARD SOLID CORE HPL REFER TO ID DRAWINGS FLUSH DOORS - - - - INTERIOR MATCH BURGER KING STANDARD ALUMINUM REFER TO ID DRAWINGS - FRAMES - - - - MATCH BURGER KING STANDARD ALUMINUM MATCH BURGER KING - - FACTORY FINISH STANDARD - MATCH BURGER KING STANDARD HOLLOW METAL EXT: SEE ELEVATION - - PAINT INT: MATCH WALL COLOR - WINDOWS MATCH BUILDING ANODIZED ALUMINUM FINISH TO MATCH FIXED GLAZING UNLESS - STANDARD OR EQUAL EXISTING BUILDING OTHERWISE NOTED ON PLANS Exterior Doors and Frames ALUMINUM DOORS & FRAMES HOLLOW MTL DOORS & FRAMES C Threshold SCALE: 3" = 1'-0" Windows and Glass Hardware Groups LOCK SET SINGLE ACTION, LEVER TYPE HINGES: CLOSER: FLOOR STOP: KICKPLATES: SILENCERS: DOOR VIEWER: HARDWARE GROUP B FALCON D271 x 626 OCCUPANCY INDICATOR LOCK SET NOTE: DELETE LOCKSET IF MULTIPLE OCCUPANCY RESTROOM SINGLE ACTION, THUMB TURN HINGES: CLOSER: PUSH PLATE: PULL PLATE: FLOOR STOP: KICKPLATES: SILENCERS: HARDWARE GROUP E ADAMS RITE MS 1852S DEADBOLT LOCK SET -- NO LOCK 3 EACH HAGER: BB1279 4 1/2 x 4 1/2 x 652 1 EACH LCN 1461 X 689 1 EACH HAGER 30S 4x16 628 1 EACH HAGER H33E 4x16 628 (OPTIONAL SANITGRASP #SG-101) 1 EACH HAGER 241F x US26D 2 EACH HAGER 193S 10"x2" LDW 628 (INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS) 3 EACH HAGER 307D RBR D Threshold SCALE: 3" = 1'-0" Revisions HINGES: OFFSET PIVOT SURFACE CLOSER: NORTON 1605 W/ BACK CHECK THRESHOLD: STANDARD DOOR PULLS: 9" CLASSIC STRAIGHT IN POLISHED STAINLESS OR CHROME REMARKS: HARDWARE GROUP F 3 EACH HAGER: BB1279 4 1/2 x 4 1/2 x 652 1 EACH LCN 1461 X 689 1 EACH HAGER 241F x US26D 2 EACH HAGER 193S 10"x2" LDW 628 (INSTALL W/FLAT HEAD PHILLIPS HEAD SCREWS) 3 EACH HAGER 307D RBR 1 EACH ROCKWOOD 622 x 626 DUMMY CYLINDERS SHALL BE PROVIDED ON THE EXTERIOR OF ALL DOORS EXCEPT AT MAIN ENTRY. E Threshold SCALE: 3" = 1'-0" HINGES: OFFSET PIVOT SURFACE CLOSER: NORTON 1605 W/ BACK CHECK THRESHOLD: NONE DOOR PULLS: 9" CLASSIC STRAIGHT IN POLISHED STAINLESS OR CHROME Albertville, MN SCHLAGE AL53PD SAT x 626 Store #14011 6495 Labeaux Ave, NE. HARDWARE GROUP A - Burger King T Project Description: T RAN # / ST-000 -Month 00, 0000 A-4.1 Door Schedule Keynotes 2 A-6.0 2. 14" TALL 'HOME OF THE WHOPPER' CHANNEL LETTERS, BY SIGN MANUFACTURER. SEE ELECTRICAL PLANS FOR POWER. 22'-0" T.O. LIGHTBAND/PARAPET 3. EXISTING WINDOW TO REMAIN, TYPICAL. 4. EXISTING CMU BLOCK TO REMAIN, PAINT AS INDICATED. 5. EXISTING CMU BLOCK VENEER TO BE REMOVED ABOVE THIS LINE. 6. EXISTING DRIVE-THRU WINDOW TO REMAIN. 14'-3" T.O. STOREFRONT 7. EXISTING DOOR TO REMAIN. 8. EXISTING GUTTER & DOWNSPOUT TO REMAIN. CONTRACTOR TO REPAIR / REPLACE AS NEEDED. PAINT IN TO MATCH WALL. EP-2. architecture.us 9. LIGHT FIXTURE, REFER TO REFLECTED CEILING PLAN & LIGHTING PLAN. phone: 1.888.666.0931 10. LIGHT BAND SUPPLIED AND INSTALLED BY OWNER. 11. EXISTING GUARDRAIL TO REMAIN, PAINT TO MATCH EP-2. Project Team: 12. TOWER ELEMENT, BEYOND. 13. BURGER KING GRAPHIC PANEL, PROVIDED AND INSTALLED BY BURGER KING 3RD PARTY 3'-0" T.O. SILL 8" 4" 14. EXISTING DOOR TO BE REPLACED 0'-0" T.O. SLAB 15. EXISTING DT SOFFIT UNDER MANSARD SHALL BE REMOVED AND REPLACED WITH WOOD SOFFIT. PAINT EP-2. 1 Main Entrance Elevation 3/16" = 1'-0" 8 7 A-6.2 A-6.2 Revisions Drive-Thru Elevation 22'-0" T.O. LIGHTBAND/PARAPET 14'-3" T.O. STOREFRONT Project Description: 4" 3'-0" T.O. SILL 0'-0" TOP OF FINISH-SLAB Albertville, MN 1 A-6.0 Store #14011 6495 Labeaux Ave, NE. 3/16" = 1'-0" Burger King 2 RAN # / ST-000 -Month 00, 0000 4 Front Elevation 3/16" = 1'-0" 3 Rear Elevation 3/16" = 1'-0" A-5.0 Exterior Elevations architecture.us phone: 1.888.666.0931 Project Team: Albertville, MN Store #14011 6495 Labeaux Ave, NE. Burger King Project Description: Revisions RAN # / ST-000 -Month 00, 0000 A-5.1 Exterior Finish Schedule Keynotes NOT ALL KEYNOTES ARE USED ON THIS SHEET. 1. EXISTING CONCRETE FOOTING. 2. EXISTING CONCRETE SLAB. 3. EXISTING 2x6 WOOD STUD WALL FRAMING. 4. EXISTING BATT INSULATION. 5. EXISTING STOREFRONT WINDOW TO REMAIN. 6. EXISTING WOOD TRUSSES. A40 A-7.1 7. EXISTING 2x4 DIAGONAL BRACING. 8. EXISTING DOUBLE WOOD TRUSSES. architecture.us 9. EXISTING GYP. BOARD. phone: 1.888.666.0931 10. EXISTING 2x6 WOOD PARAPET FRAMING. 11. EXISTING ROOFING SYSTEM OVER EXISTING RIGID INSULATION. Project Team: 12. EXISTING 4" SPLIT FACE BLOCK VENEER. A34 13. BASE AS SCHEDULED. A-7.1 14. METAL FLASHING. 15. EXISTING BLOCK VENEER TO BE REMOVED. 17'-2" T.O. LIGHT BAND 16. WATER RESISTIVE MOISTURE BARRIER ON 1/2" CDX PLYWOOD SHEATHING. 17. 1 1/2" E.I.F.S. PRODUCT, TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 18. CONTINUOUS METAL FLASHING. 15'-6" T.O. EXIST. PARAPET 15'-6" T.O. EXIST. PARAPET 15'-6" T.O. EXIST. PARAPET 19. CEILING AS SCHEDULED. 20. METAL CANOPY, BY OTHERS. 21. EXISTING MANSARD ROOF TO BE REMOVED. 22. 2x BLOCKING AS REQUIRED. 23. NICHIHA. 24. 2x4 WOOD STUD FRAMING @ 24" O.C. 25. 2x6 WOOD STUD FRAMING @ 24" O.C. 26. SIGNAGE, BY OTHERS. 27. 2x4 BRACING @ 24" O.C. MAX. 28. (2) 10d @ EACH MEMBER, TYPICAL. 29. ROOFING SYSTEM OVER 1/2" CDX PLYWOOD. MATCH TO EXISTING ROOF SYSTEM. 30. WELD NEW ROOFING SYSTEM TO EXISTING. 31. SILL AS SCHEDULED. 32. EXISTING WOOD BEAM. 33. H2.5 SIMPSON TIE. 1'-0" 1'-0" 1'-0" 2'-0" 4'-0" 34. EXISTING STOREFRONT DOOR TO BE REPLACED. 35. EXISTING DOOR SILL TO BE REPLACED. 4" 4" 36. EXISTING ADJACENT GRADE. 37. EXISTING MANSARD ROOF TO BE REPLACED WITH WOOD SOFFIT. 38. EXISTING METAL FLASHING FASCIA TO BE PAINTED BLACK. Albertville, MN 0'-0" FINISH FLOOR Store #14011 6495 Labeaux Ave, NE. 0'-0" FINISH FLOOR Project Description: 0'-0" FINISH FLOOR Burger King Revisions RAN # / ST-000 -- 3 Section at Side Entrance Tower 3/4" = 1'-0" 2 Section at Window & Canopy 3/4" = 1'-0" 1 Section at Front Entrance Tower 3/4" = 1'-0" Month 00, 0000 A-6.0 Wall Sections Keynotes NOT ALL KEYNOTES ARE USED ON THIS SHEET. 1. EXISTING CONCRETE FOOTING. 2. EXISTING CONCRETE SLAB. 3. EXISTING 2x6 WOOD STUD WALL FRAMING. 4. EXISTING BATT INSULATION. 5. EXISTING STOREFRONT WINDOW TO REMAIN. 6. EXISTING WOOD TRUSSES. 7. EXISTING 2x4 DIAGONAL BRACING. 8. EXISTING DOUBLE WOOD TRUSSES. architecture.us 9. EXISTING GYP. BOARD. phone: 1.888.666.0931 10. EXISTING 2x6 WOOD PARAPET FRAMING. 11. EXISTING ROOFING SYSTEM OVER EXISTING RIGID INSULATION. Project Team: 12. EXISTING 4" SPLIT FACE BLOCK VENEER. 13. BASE AS SCHEDULED. A38 A38 A-7.1 A-7.1 14. METAL FLASHING. 15. EXISTING BLOCK VENEER TO BE REMOVED. 17'-0" T.O. EXIST. PARAPET 17'-0" T.O. EXIST. PARAPET 16. WATER RESISTIVE MOISTURE BARRIER ON 1/2" CDX PLYWOOD SHEATHING. 17. 1 1/2" E.I.F.S. PRODUCT, TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 18. CONTINUOUS METAL FLASHING. 19. CEILING AS SCHEDULED. 20. METAL CANOPY, BY OTHERS. 21. EXISTING MANSARD ROOF TO BE REMOVED. 14'-3" T.O. STOREFRONT 22. 2x BLOCKING AS REQUIRED. 23. NICHIHA. 24. 2x4 WOOD STUD FRAMING @ 24" O.C. 25. 2x6 WOOD STUD FRAMING @ 24" O.C. 26. SIGNAGE, BY OTHERS. 27. 2x4 BRACING @ 24" O.C. MAX. 28. (2) 10d @ EACH MEMBER, TYPICAL. 29. ROOFING SYSTEM OVER 1/2" CDX PLYWOOD. MATCH TO EXISTING ROOF SYSTEM. 30. WELD NEW ROOFING SYSTEM TO EXISTING. 31. SILL AS SCHEDULED. 10'-0" B.O. CANOPY 32. EXISTING WOOD BEAM. 33. H2.5 SIMPSON TIE. 34. EXISTING STOREFRONT DOOR TO BE REPLACED. 35. EXISTING DOOR SILL TO BE REPLACED. 36. EXISTING ADJACENT GRADE. 37. EXISTING MANSARD ROOF TO BE REPLACED WITH WOOD SOFFIT. 38. EXISTING METAL FLASHING FASCIA TO BE PAINTED BLACK. Revisions Albertville, MN 0'-0" FINISH FLOOR Store #14011 6495 Labeaux Ave, NE. 0'-0" T.O. SLAB Project Description: 0'-0" FINISH FLOOR Burger King 3'-0" T.O. SILL RAN # / ST-000 -- 6 Section at Side Wall 3/4" = 1'-0" 5 Section at Playground 3/4" = 1'-0" 4 Section at Side Wall 3/4" = 1'-0" Month 00, 0000 A-6.1 Wall Sections Keynotes NOT ALL KEYNOTES ARE USED ON THIS SHEET. 1. EXISTING CONCRETE FOOTING. 2. EXISTING CONCRETE SLAB. 3. EXISTING 2x6 WOOD STUD WALL FRAMING. 4. EXISTING BATT INSULATION. 5. EXISTING STOREFRONT WINDOW TO REMAIN. 6. EXISTING WOOD TRUSSES. 7. EXISTING 2x4 DIAGONAL BRACING. 8. EXISTING DOUBLE WOOD TRUSSES. architecture.us 9. EXISTING GYP. BOARD. phone: 1.888.666.0931 10. EXISTING 2x6 WOOD PARAPET FRAMING. 11. EXISTING ROOFING SYSTEM OVER EXISTING RIGID INSULATION. Project Team: 12. EXISTING 4" SPLIT FACE BLOCK VENEER. 13. BASE AS SCHEDULED. 14. METAL FLASHING. 15. EXISTING BLOCK VENEER TO BE REMOVED. 16. WATER RESISTIVE MOISTURE BARRIER ON 1/2" CDX PLYWOOD SHEATHING. 17. 1 1/2" E.I.F.S. PRODUCT, TO BE APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 18. CONTINUOUS METAL FLASHING. 15'-6" T.O. LIGHT BAND 15'-6" T.O. LIGHT BAND 19. CEILING AS SCHEDULED. 20. METAL CANOPY, BY OTHERS. 21. EXISTING MANSARD ROOF TO BE REMOVED. 22. 2x BLOCKING AS REQUIRED. 23. NICHIHA. 24. 2x4 WOOD STUD FRAMING @ 24" O.C. 25. 2x6 WOOD STUD FRAMING @ 24" O.C. 26. SIGNAGE, BY OTHERS. 27. 2x4 BRACING @ 24" O.C. MAX. 28. (2) 10d @ EACH MEMBER, TYPICAL. 29. ROOFING SYSTEM OVER 1/2" CDX PLYWOOD. MATCH TO EXISTING ROOF SYSTEM. 30. WELD NEW ROOFING SYSTEM TO EXISTING. 31. SILL AS SCHEDULED. 32. EXISTING WOOD BEAM. 33. H2.5 SIMPSON TIE. 34. EXISTING STOREFRONT DOOR TO BE REPLACED. 35. EXISTING DOOR SILL TO BE REPLACED. 36. EXISTING ADJACENT GRADE. 37. EXISTING MANSARD ROOF TO BE REPLACED WITH WOOD SOFFIT. 38. EXISTING METAL FLASHING FASCIA TO BE PAINTED BLACK. RAN # / ST-000 -- 8 Section at Drive thru 3/4" = 1'-0" 7 Section at Side Wall 3/4" = 1'-0" Month 00, 0000 A6.2 Wall Sections Albertville, MN Store #14011 6495 Labeaux Ave, NE. 0'-0" FINISH FLOOR Project Description: 0'-0" FINISH FLOOR Burger King Revisions architecture.us phone: 1.888.666.0931 Project Team: M1 P- Exhaust Fan Mounting SCALE: NOT TO SCALE Accessible Sink SCALE: NOT TO SCALE P9 P- Instant Water Heater SCALE: NOT TO SCALE Accessible Sink SCALE: NOT TO SCALE # # Column Surround Element SCALE: 1 1/2" = 1'-0" Corner Guard Detail SCALE: NOT TO SCALE A5 A6 Clearances at Doors SCALE: NOT TO SCALE Accessible Threshold SCALE: 1'-0" = 1'-0" A1 P4 Interior Wall SCALE: NOT TO SCALE Urinals and Showers SCALE: NOT TO SCALE Ceiling Grid Bracing SCALE: NOT TO SCALE P2 Water Closets, Grab Bars SCALE: NOT TO SCALE P2 Water Closets, Grab Bars SCALE: NOT TO SCALE Albertville, MN SCALE: NOT TO SCALE A7 Store #14011 6495 Labeaux Ave, NE. SCALE: 3" = 1'-0" A15 Accessible Entry Window Decal Project Description: A19 E.I.F.S. Horizontal Reveal Burger King Revisions RAN # / ST-000 -Month 00, 0000 A20 Device Location Diagram SCALE: NOT TO SCALE A12 Light Fixture Support SCALE: NOT TO SCALE A8 Restroom Signage SCALE: NOT TO SCALE A4 Low Wall SCALE: NOT TO SCALE A-7.0 Architectural Details Division 4 - Masonry Division 9 - Finishes Division 15 - Mechanical Division 16 - Electrical (continued) Sign, Equipment, ... (continued) architecture.us phone: 1.888.666.0931 Project Team: Division 5 - Metals Division 6 - Wood / Plastics Sign, Equipment, Playground & Decor Division 7 - Thermal Moisture Protection Division 10 - Specialties Revisions Albertville, MN Store #14011 6495 Labeaux Ave, NE. Project Description: Division 16 - Electrical Burger King Division 8 - Doors and Windows RAN # / ST-000 -Month 00, 0000 A-8.0 Manufacturers & Suppliers