Back Next Go to Table of Contents VetPro® 5000 WHIP Delivery Dental Systems Model Numbers: 8001-001-341 8001-002-341 8001-003-341 8001-005-341 8001-006-341 8001-007-341 8001-009 8001-010 Stationary Units Service and Parts Manual Mobile Units VetPro® Solo Also Includes VetPro® Solo 8006-001 FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY 004-0685-00 Rev (7/21/16) Back Next © Midmark Corporation 2008 SF-1930 Theory of Operation.............................A-1 thru A-5 Troubleshooting Charts.....................A-6 thru A-14 Testing & Repair Mobile Models Only Air Water Regulator........................................... B-2 Water System.................................................... B-3 Electrical Box..................................................... B-4 Pressure Switch, Timer & Solenoid................ B-5 Compressor........................................................ B-7 Intake Filter......................................................... B-8 Capacitor............................................................ B-9 Checking for Air Leaks.................................... B-10 Check Valves....................................................B-11 Stationary Models Only Pressure Regulators....................................... B-12 Manual Shut-Off Valves.................................. B-13 Water Toggle Switch....................................... B-16 Water Bottle...................................................... B-17 All Models Coolant Water Flush Button........................... B-18 Wet/Dry Foot Control...................................... B-20 Master On/Off Switch...................................... B-22 Flex Arm Lock (Valve)..................................... B-23 Coolant Water Control Valve...................... B-26 Kink Valves....................................................... B-28 Handpiece Adjustments.................................. B-30 [Revised: 03/31/09] ii Section B access procedures Section C Operation & Troubleshooting All Models Delivery Indicators........................................... B-31 Handpiece Check Valves............................... B-32 Air / Oil Separator............................................ B-33 Fiber Optic (Optional)..................................... B-34 Scaler Testing.................................................. B-35 LED Scaler Testing............................................. B-36 Section D Symbols..................................................................iii Ordering Parts........................................................iii Serial Number Location........................................iii Specifications........................................................ iv Model Description.................................................. v Scheduled Maintenance...................................... vi Warranty Information...........................................vii Linked Files Section E General Info Section A Testing & Repair - continued GENERAL INFORMATIOn Section B Table of Contents Go to Table of Contents Instrument Head................................................ C-2 Junction Box....................................................... C-3 Water System.................................................... C-4 Flex Arm.............................................................. C-5 Rear Access Panel........................................ C-6 Electrical Box..................................................... C-7 Shrouds (Front, Back and Top)....................... C-8 Enclosure (Black Box).................................. C-9 Cover (Solo)............................................... C-10 Tubing & Wiring Diagrams Instrument Head Tubing................................... D-2 Junction Box Tubing ......................................... D-3 Water Bottle Tubing (Wall/Cabinet Mount).... D-4 Water Bottle Tubing (Mobile Unit)................... D-5 Tubing Diagram (Mobile Unit).......................... D-6 Electrical Diagram (Mobile Unit)...................... D-7 Electircal Diagram (Wall/Cabinet Mount)....... D-8 Exploded Views & Parts Lists Wall / Cabinet & Table Mount.......................... E-2 Mobile Unit......................................................... E-3 Solo Unit....................................................... E-4 REpair procedures & forms Water Regulator................................ 003-1958-00 Air Regulator..................................... 003-1959-00 Water Selector Replacement ............ 003-1960-00 Flush Valve Replacement.................. 003-1962-00 Kink Valve Replacement................... 003-1961-00 (*) Indicates multiple pages due to model / serial number break (s). Back Next General Information Go to Table of Contents © Midmark Corporation 2008 SF-1930 Symbols Ordering Parts danger Indicates an imminently hazardous situation which will result in serious or fatal injury if not avoided. This symbol is used only the most extreme conditions. Non-warranty parts orders may be faxed to Midmark using the Fax Order Form in the back of this manual. warning The following information is required when ordering parts: • Serial number & model number • Part number for desired part (Refer to Section E: Exploded Views & Parts Lists) Indicates a potentially hazardous situation which could result in serious injury if not avoided. Caution Indicates a potentially hazardous situation which may result in minor or moderate injury if not avoided. It may also be used to alert against unsafe practices For warranty parts orders, call Midmark’s Technical Service Department with the required information. Hours: 8:00 am to 5:00 p.m. EST (Monday thru Friday) Phone: 1-800-Midmark (1-800-643-6275) Serial Number Location Stationary Units Equipment Alert Indicates a potentially hazardous situation which could result in equipment damage if not avoided. Note Used for special instructions or additional information. The symbols below may be used in this manual to represent the operational status of table functions and components. Indicates the function / component is working properly. No action required. Indicates the function / component is working, but a problem exists. Indicates the function is not working at all, or that the component is faulty. [Revised: 03/10/09] iii Mobile Units Serial Number Label Model / Serial Number Location Back Next Go to Table of Contents Specifications Stationary Units Mobile Units Cart Cabinet/Table Width 21 inches (53.3 cm) Width 29 inches (73.7 cm) Length 28 inches (71.1 cm) Length 41 inches (104.1 cm) Height 54 to 68 inches (137 to 172.7 cm) Height 21.5 inches (54.6 cm) Weight 195 lbs (88.5 kg) Weight 82 lbs (37 kg) Shipping Weight 218 lbs (98.9 kg) Shipping Weight 92 lbs (42 kg) Top of Cart Weight Restriction 40 lbs ( 18.1 kg) Water Module Electrical Voltage 115 VAC Frequency 60 Hz Circuit Breaker Protection Hospital Grade Wiring 15 amps NEMA type: 14 and 18 AWG Accessory Outlet (User Specs) Receptacles (Top of Electrical Box) NEMA Outlet, Snap AC Connector, 15 amp, 125 VAC Plug Pressurized System 30 - 50 PSI Aseptic Non-Retracting HPC Coolant Handpiece Flush System Manual 10 amps, 250 VAC “City” Water Regulator Valve 30 PSI Air Regulator Valve 80 PSI Water Bottle Regulator Valve 30 PSI 9 1/2 ft. NEMA 5-15R Electrical Handpiece Connection Type Midwest 4-Hole Type Handpiece Compressor Motor Oil Free 1/3 HP Working Pressure 80 - 100 PSI Flow Rate 2.6 scfm @ 45 PSI Sound Level (full load) Reservoirs Aseptic Handpiece Flush System 4 gal 15 Liter Two - 1 Liter - Toggled 30 PSI Non-Retracting HPC Coolant [Revised: 03/01/10] Frequency 60 Hz Manual © Midmark Corporation 2008 SF-1930 115 VAC 15 amps The Acteon Newtron® LED scaler complies with current electromagnetic compatibility standards. However, it must not be used by or on those with cardiac stimulators or other active implants unless adequate electromagnetic interference shielding is present. Check with a cardiologist to verify the EMI shielding capabilities of the implant. See enclosed Newtron® LED manual for further advisories. Water Module Pressurized System Voltage Circuit Breaker Protection warning < 55 dB Air Tank One - 1 Liter Toggled with Reservoir Recommended Pressure Settings GFCI 5 amps, 125 VAC Power Cord Length Reservoir City Water warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. iv Back Next Go to Table of Contents Specifications & Model Descriptions Models Solo Units Dimensions Model Description Width 12.75 inches (32.4 cm) 8001-001-341 VetPro® 5000 Wall Mount Length 20.89 inches (53 cm) 8001-002-341 VetPro® 5000 Cabinet Mount Height 11.40 inches (29 cm) 8001-003-341 VetPro® 5000 Table Mount Weight 54 lbs ( 24.5 kg) 8001 -005-341 VetPro® 5000 Wall Mount - Lighted Hand Pieces Shipping Weight 61 lbs ( 27.7 kg) 8001-006-341 VetPro® 5000 Cabinet Mount - Lighted Hand Pieces 8001-007-341 VetPro® 5000 Table Mount - Lighted Hand Pieces Electrical Voltage 115 VAC Frequency 60 Hz Circuit Breaker Protection Hospital Grade Wiring Accessory Outlet (Side Mounted, User Specs) 15 amps 8001-009 VetPro® 5000 Mobile 8001-010 VetPro® 5000 Mobile - Lighted Hand Pieces 8006-001 VetPro® Solo NEMA type: 14 and 18 AWG GFCI 5 amps, 125 VAC Receptacles (Top of Electrical Box) NEMA Outlet, Snap AC Connector, 15 amp, 125 VAC Plug 15 amps, 125 VAC Power Cord Length 5 ft. NEMA 5-15R Compressor Motor Oil Free 1/3 HP Working Pressure 80 - 100 PSI Flow Rate 2.6 scfm @ 45 PSI Sound Level (full load) < 55 dB Air Tank 1 gal 3.79 Liter Water Connection Water Inlet Length 10 ft. (3 m) Water Inlet Thread Size 3/8” FNPT Saddle Valve Adapter Length Saddle Clamp Range 2 ft. (.61 m) 3/8” - 1 5/16 ” OD Copper Pipe © Midmark Corporation 2008 SF-1930 [Revised: 5/10/12] warning Equipment not suitable for use in the presence of a flammable anesthetic mixture. v Back Next Go to Table of Contents Scheduled Maintenance Chart Scheduled Maintenance Interval After Each Procedure Inspection / Service Clean Handpieces Refer to handpiece manufacture’s documentation. Flush Handpieces Refer to: Operating and Care Guide Tri-fold or CD, located in plastic sleeve with unit. Fill Water Bottle Daily Description Refer to: Water Bottle in this manual. Clean System Refer to: Operating and Care Guide Tri-fold or CD, located in plastic sleeve with unit. Empty Water System and or Drain Air Storage Tank. Refer to: Operating and Care Guide Tri-fold or CD, located in plastic sleeve with unit. Obvious damage Visually check condition of delivery system for obvious damage such as: cracks in components, missing components, dents in components, or any other visible damage which would cause the delivery system to be unsafe to operate or would compromise its performance. Repair delivery system as necessary. Fasteners / Hardware Check delivery system for missing or loose fasteners / hardware. Replace and or tighten as necessary. Semi-Annually Annually (Mobile and Solo Models Only) Warning and Instructional Decals Check for missing or illegible decals. Replace decals as necessary. Tubing Connections Remove covers and check for loose or damaged tubing connections. Check for air/water leaks or other visible damage. Reconnect and or repair/ replace tubing as necessary. Kink Valves Remove delivery head cover and check kink valves for air/water leaks and proper operation. Replace kink valves if necessary. Regulator Valves Check that regulator valves are set to the recommended settings. Water Regulator - 30 PSI Air Regulator w/gauge - 80 PSI Air Regulator w/o gauge: - Factory set at 30 PSI (Do not adjust) Adjust regulator valves as necessary. - Refer to Pressure Regulators in Section B. Delivery Unit Flex Arm Check that flex arm will not move downward without depressing Unlock Buttons on delivery head. Replace or adjust any malfunctioning components. Filters Replace Intake and Solenoid filters annually. Refer to Section B. Date of Service: Model Number: Location: Serial Number: Service Technician: Notes: © Midmark Corporation 2008 SF-1930 [Revised: 5/1/09] vi Back Go to Table of Contents Warranty Limited Warranty SCOPE OF WARRANTY Midmark Corporation (“Midmark”) warrants to the original purchaser The VetPro® 5000 delivery systems (except for components not warranted under “Exclusions”) manufactured by Midmark to be free from defects in material and workmanship under normal use and service. Midmark’s obligation under this warranty is limited to the repair or replacement, at Midmark’s option, of the parts or the products the defects of which are reported to Midmark within the applicable warranty period and which, upon examination by Midmark, prove to be defective. APPLICABLE WARRANTY PERIOD The applicable warranty period, measured from the date of delivery to the original user, shall be as follows: DENTAL PRODUCTS are warranted against defect in material and workmanship for the period indicated below from the time of delivery: a) 2 years for all products and components (except for the periods in b through e). b) “KINK-VALVE” module carries a 10 year warranty. c) The original light bulb on a new light carries a 1 year warranty. d) Accessories not manufactured by Midmark are excluded (i.e. Fiber optic systems, Scalers, Handpieces, etc.). e) Replacement parts and accessories carry a 90 day warranty. EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following: (1) repairs and replacements because of misuse, abuse, negligence, alteration, accident, freight damage, or tampering; (2) matching of color, grain, or texture except to commercially acceptable standards; (3) changes in color caused by natural or artificial light; (4) products which are not installed, used, and properly cleaned as required in the Midmark “Installation” and or “User” and or “Service” Manual for this applicable product; (5) products considered to be of a consumable nature; (6) accessories or parts not manufactured by Midmark; (7) specially manufactured products; (8) charges by anyone for adjustments, repairs, replacement parts, installation, or other work performed upon or in connection with such products which is not expressly authorized in writing in advance by Midmark. EXCLUSIVE REMEDY Midmark’s only obligation under this warranty is the repair or replacement of defective parts. Midmark shall not be liable for any direct, special, indirect, incidental, exemplary, or con-sequential damages or delay, including, but not limited to, damages for loss of profits or loss of use. NO AUTHORIZATION No person or firm is authorized to create for Midmark any other obligation or liability in connection with the products. THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS. © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] vii Next Back Next Section A Go to Table of Contents © Midmark Corporation 2008 SF-1930 Operation & Troubleshooting [Revised: dd/mo/yr] A-1 Theory of Operation (Mobile).............A-2 Electrical (Mobile)...............................A-3 Theory of Operation (Wall/Cabinet)....A-4 Handpiece Operation.........................A-5 Delivery Troubleshooting.... A-6 thru A-12 Flex Arm Troubleshooting.................A-13 Compressor Troubleshooting...........A-14 Back Next Go to Table of Contents Theory of Operation - Mobile and Solo Unit Troubleshooting .................................A-3 Compressor When the compressor is running, atmospheric air is drawn in through the intake filter to the compressor head where air is compressed and discharged to a storage tank. A check valve is placed between the compressor head and the storage tank to prevent air flow back to the head. The solenoid allows air to escape for approximately two seconds during start-up to relieve pressure from the head, then closes sending pressurized air to the storage tank. When the pressure in the storage tank reaches a predefined level, the pressure switch is activated stopping the compressor. A drain valve is located on the bottom of the storage tank. Loosen the wing nut on the drain valve to discharge air and water from the tank. Moblie Unit Shown Air Flow Air also flows from the storage tank to the master pilot shut-off valve which controls supply air to the WHIP head master on/off switch and the air regulator. The air regulator maintains air pressure at 55 PSI. Regulated air then flows to the syringe, foot control and water pressure regulator to power the functions of the Whip Head. Whip Head When the foot control pedal is depressed, a valve in the foot control opens and supplies drive and coolant air to the pilot valve. Air from the pilot valve is supplied to each handpiece kink valve. The drive air to each hand piece is regulated by individual adjustment valves located prior to the kink valves. Coolant air is supplied to the handpiece coolant air adjustment valve. The coolant air is regulated by the adjustment valve then directed to the kink valves. When the Wet/Dry toggle valve is switched to the Wet position, pilot air to the coolant water control valve allows coolant water to be supplied to the coolant water adjustment valves. From the coolant water adjustment valves, coolant water travels to the kink valves. The water pressure regulator supplies air to the water bottles at 30 PSI. The toggle switch opens and closes the air flow to the water bottles. When the toggle switch is flipped toward a bottle, that bottles valve opens and allows water flow to the WHIP Head. Foot Control Wet/Dry Toggle Air Storage Tank 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] Foot Control Tubing Solenoid Pressure Switch Air Regulator Umbilical - To Delivery Head Intake Filter Air From Regulator When a handpiece is lifted, the WHIP assembly pivots causing the pilot valve to close. The closed pilot valve allows air to flow to the kink valve assembly causing kink valve tubing to relax (open). Coolant air, drive air, and coolant water flow through the relaxed kink tubing to the handpiece. The user can adjust air and water flow by using the controls on front and bottom of the delivery. Models: Throttle Valve Compressor Water to Delivery Head Master Pilot Shut-Off Valve Drain Valve Water System A-2 Always verify model & serial number Back Next Go to Table of Contents Theory of Operation continued - Mobile and Solo Unit Electrical • Supply line voltage is always present at the mobile unit power cord receptacle when plugged into a wall receptacle. When the On/ Off switch is turned on, line voltage, 115 VAC, is supplied to the pressure switch, fan and receptacles (accessory, scaler & fiber optics). • The system will continue to run until the pressure inside the system reaches 100 PSI (+ / - 5 PSI) (Cut-out time). It will turn back on when the pressure lowers to 80 PSI (+ / - 5 PSI) (Cut-in time). • The timer keeps the solenoid turned off until the compressor is running at full RPM. The solenoid allows air to escape for approximately two seconds to relieve pressure from the head, then closes sending pressurized air to the storage tank. • A thermostat controlled fan helps keep the compressor cool. The fan is energized when the temperature inside the enclosure reaches 95° F (35° C). Moblie Unit Shown • Receptacles in the electrical box provide power for the scaler, optional fiber optics and accessories. • The 24 VAC scaler and fiber optic power supplies plug into the top of the electrical box. Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] A-3 Always verify model & serial number Back Next Go to Table of Contents Theory of Operation - Stationary Units Troubleshooting .................................A-3 When the master On/Off switch is turned to On, supply air passes through the On/Off switch valve to the water master pilot valve block, the air master pilot valve block, syringe, water bottle and foot control pressure indicator. Wall Mount Shown Air Flow The air pilot valve block directs air through two air regulators. One regulates air to 30 PSI and supplies the water bottles with air pressure. The other supplies the foot control with air regulated at 80 PSI. When the foot control pedal is depressed, the valve (in foot control) opens and supplies drive air and coolant air to the pilot valve for the kink valves. Drive air is supplied to each handpiece kink valve. The drive air is regulated by adjustment valves prior to the kink valves. Coolant air is supplied to the handpiece coolant air adjustment valve. The coolant air is regulated by the adjustment valve then directed to the kink valves. Water Flow City and bottle water are set at 30 PSI when air flows through the water regulator and directed to the city/bottle water selector. Distilled water is supplied to the water toggle switch from the water bottle. With the toggle switch toggle switch in City or Bottle position water flows through the toggle switch to the water supply system. The water supply system directs the flow of water to the syringe adjustment valve and the coolant water control valve. When the Wet / Dry toggle valve is switched to the Wet position, pilot air to the coolant water control valve allows coolant water to be supplied to the coolant water adjustment valves. From the coolant water adjustment valves, coolant water travels to the kink valves. Handpiece Operation When a handpiece is lifted, the whip assembly pivots causing the pilot valve to close. The closed pilot valve allows air to flow to the kink valve assembly causing kink valve tubing to relax (open). Coolant air, drive air, and coolant water flow though the relaxed kink tubing to the handpiece. The user can adjust air and water flow by using the controls on front of the delivery. Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] Foot Control Transformer Air Pressure Switch Valve Master Pilot Shut-Off Manual Shut-Off Valve (Air) NOTE: The outgoing water line from the toggle switch is used for both City and Bottle water. J-Box Air Regulators Umbilical Master Pilot Shut-Off Manual Shut-Off Valve (Water) 8001-005 8001-006 8001-007 all all A-4 all Always verify model & serial number Back Next Go to Table of Contents Basic Operation - Handpieces The automatic kink valves activate a handpiece when it is removed from the resting position and brought forward of the instrument head. Drive air will be delivered to the withdrawn handpiece when the foot control is depressed. Resting Position Not In Use Open Position In Use Step 1: Turn master switch on. Step 3: Lift the handpiece and pull it forward of the instrument head. Depress foot control. Note: If necessary, make adjustments with the control knobs as desired. Refer to: Section B, Handpiece Adjustments Step 2: Flip wet/dry toggle on foot control to desired position. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] A-5 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem None of the handpieces or syringe will function. Handpieces will not run. One handpiece does not run; all other handpieces work properly. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Symptom There is no water or air present at any of the handpieces or syringe. Probable Cause Check Correction Master ON/OFF switch is turned off or malfunctioning. Check that master ON/Off switch is turned on. Replace master On/OFF switch if necessary. Air master pilot shut-off valve is malfunctioning. Disconnect 1/8” purple turning from air master pilot shut-off valve and check for air pressure. If there is no pressure, replace air master pilot shut-off valve. Refer to: Section B Master Pilot Shut-Off Valve Air manual shut-off valve is turned off or malfunctioning. (STATIONARY MODELS ONLY) Check that air manual shut-off valve is turned on. Contact a licensed plumber to replace air manual shut-off valve. Handpieces do not run or have water. Syringe works properly. Valve (in foot control) is malfunctioning -stuck closed. Disconnect 1/4” clear tubing from 5/16” clear tubing (foot control tubing). Check for air pressure. If there is no pressure, replace entire foot control (drive air foot pedal valve is not available). Handpieces do not run or have water. Syringe has water, but no air. Tubing from air regulator damaged or disconnected. Check: 5/16” clear tubing w/ dash (from foot control) and 1/8” yellow tubing (from umbilical to delivery unit) for damage and proper connections. Replace damaged tubing. Reconnect any disconnected tubing. Air regulator is turned too low or malfunctioning. Check that air regulator output pressure is 65 PSI for Stationary models & 55 PSI for Mobile Models. Adjust air regulator output pressure to 65 PSI for Stationary models & 55 PSI for Mobile Models. If necessary, clean or replace air regulator. Handpieces have water but do not Damaged or disconnected drive air Check: 5/16” tubing w/o dash (from run. Syringe works properly. tubing to delivery / whip head. foot control) AND 1/4” clear tubing to handpiece supply drive air manifold for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. One handpiece does not run or have water; all other handpieces work properly. Kink valve is malfunctioning. Check to see if kink valve “unkinks” when handpiece is lifted forward. Adjust or replace kink valve. Refer to: Section B Kink Valves Damaged or disconnected tubing in delivery head. Check: 1/8” red tubing between piReplace damaged tubing. lot air manifold and handpiece on/off Reconnect any disconnected valve AND 1/8” purple tubing between tubing. handpiece on/off valve and kink valve for damage and proper connection. One handpiece does not run, but has water and coolant air; all other handpieces work properly. Drive air adjustment valve adjusted too low or malfunctioning. Check drive air adjustment valve of malfunctioning handpiece. Adjust drive air adjustment valve; replace if necessary. Refer to: Section B Handpiece Adjustments All all [Revised: 03/10/09] A-6 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem Symptom One handpiece does not run; all other handpieces work properly. - Continued One handpiece does not run, but has water and coolant air; all other handpieces work properly. - Continued No water to handpieces or syringe. Handpieces run properly. With toggle switched to bottle water handpiece and syringe has not water flow. City water works fine. (Moblie units will only have water bottles.) NOTE: When troubleshooting With water toggle switch City position there is no water to handpieces or syringe; Bottle position functions properly. (STATIONARY With Solo unit MODELS ONLY) Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Probable Cause Check Correction Damaged or disconnected tubing in delivery head. Check 1/4” clear tubing between: drive air manifold (delivery unit) and drive air adjustment valve AND drive air adjustment valve and kink valve for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. Water bottle is empty. Water bottle is empty. Check that water bottle is full. Fill water bottle with distilled water. Water bottle gasket damaged or missing. Check for air leaking from top of water bottle. Replace water bottle gasket. Water bottles are not pressuized. Remove 1/8” brown tubing. Verify error signal. If not, locate kink or obstruction. For uints with junction box, verify water bottle requlator is set to 30 psi. Water toggle switch malfunctioning. Disconnect “out-going” water line tubing from water toggle switch and check for water pressure. If there is no water pressure, clean or replace water toggle switch. Refer to: Section B Water Toggle Switch Damaged or disconnected tubing Check: 1/8” tubing between water toggle switch Replace damaged tubing. Reconnect any and double pinch valve for damage and proper disconnected tubing. connection. Check valves. (Mobile unit) Remove 1/8” blue tubing from check valve and verify water pressure. If none present, change check valve. Water toggle switch malfunctioning. Disconnect incoming city water line from water toggle switch and check for water pressure. If there is water pressure, clean or replace water toggle switch. Refer to: Section B Water Toggle Switch Water manual shut-off valve (in junction box) is turned off or malfunctioning. Check that water manual shut-off valve is turned on. Contact a licensed plumber to replace shutoff valve if necessary. Water regulator (in junction box) is turned too low or malfunctioning. Check that water regulator output pressure is 30 PSI. Adjust water regulator output pressure to 30 PSI. Clean or replace water regulator if necessary. Water master pilot shut-off valve (in junction box) is malfunctioning. Disconnect 1/8” tubing from water master pilot shut-off valve and check for water pressure. If there is no water pressure, replace water master pilot shut-off valve. Damaged or disconnected tubing. Check: 1/8” blue tubing between water regulator (in junction box) and water toggle switch for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. All all [Revised: 03/10/09] A-7 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem No water to handpieces or syringe. Handpieces run properly. - Continued Symptom With water toggle switch (City / Bottle toggle switch) in Bottle position there is no water to handpieces or syringe; City position functions properly. (STATIONARY MODELS ONLY) Probable Cause Check that water bottle air regulator output pressure is set at 30 PSI. Adjust water bottle air regulator output pressure to 30 PSI. Clean or replace regulator if necessary. Damaged or disconnected tubing. Check: 1/8” brown tubing between water bottle air regulator (in junction box) and water bottle cap for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. Check: 1/8” blue tubing between water bottle cap and water toggle switch for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. Clogged tip Remove tip and verify water flow If water is present, then replace tip. Blockage in syringe. Remove incoming water tube and verify If water is present, disassemble and clean water flow. syringe or replace. Damaged, clogged, or disconnected tubing. Follow water flow and identify where water flow is not present. Clear debris, repair tubing or replace tubing. Refer to: Section D Tubing Diagrams Water toggle switch malfunctioning. Check toggle. Disconnect 1/8” blue tubing (from water bottle) from water toggle switch and check for water pressure. If there is water pressure, clean or replace water toggle switch. Refer to: Section B Water Toggle Switch Check that toggle switch is turned to Wet. Turn toggle switch to Wet. Check for water pressure at output of coolant water toggle valve. Replace toggle valve on foot control. Check 1/8” orange tubing (from umbilical) for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. No water to syringe off city/bottle water, all other handpieces function properly. Water leak at toggle. Water dripping No water to handpieces. Syringe works properly. All handpieces run and syringe Toggle switch on foot control is works properly, but there is no wa- turned to Dry. ter to any of the handpieces. Toggle switch on foot control is malfunctioning. Serial Numbers: © Midmark Corporation 2008 SF-1930 Correction Water bottle air regulator (in junction box) set too low or malfunctioning. No water to syringe, but other handpieces function properly. Models: Check Damage or disconnected tubing. Coolant water adjustment Check coolant water adjustment valve valve is adjusted too low or is of malfunctioning. malfunctioning handpiece. Adjust coolant water adjustment valve: replace if necessary. Refer to: Section B Handpiece Adjustments Coolant Water Control Valve malfunctioning. If necessary replace coolant water control valve. Refer to tubing diagram. Refer to: Section B Handpiece Adjustments Disconnect 1/8” blue outlet line and check for water during operation. All all [Revised: 6/3/13] A-8 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem No water to handpieces. Syringe works properly. Continued Water leaks from handpiece when removed from holder. Symptom Probable Cause Handpiece runs, but there is no water to that handpiece. Other handpieces work properly. - Continued Damaged or disconnected tubing in delivery unit. When any handpiece is pulled forward, water comes out without foot control pedal being depressed. Check Correction Check 1/8” blue tubing between water supply manifold and coolant water adjustment valve AND between coolant water adjustment valve and kink valve of malfunctioning handpiece for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. Check 1/8” white tubing between coolant water adjustment valve and kink valve AND between kink valve and check valve. Replace damaged tubing. Reconnect any disconnected tubing. Coolant water toggle valve is malfunctioning - bleed port (toggle valve) is clogged allowing pressure to remain in air line. Pull off orange signal line and check for residual air pressure (residual air pressure indicates bleed port is not working). Replace toggle valve in foot control. Refer to: Section B Foot Control Coolant water flush valve is malfunctioning stuck open. Replace suspect coolant water flush valve with known working flush valve. Replace coolant water flush valve. Refer to: Section B Coolant Water Flush Valve Check valve of malfunctioning handpiece is defective and stuck open. Inspect handpiece check valve (connected to 1/8” clear tubing for handpiece), to see if it is stuck open or replaced suspect check valve with known working check valve. Replace handpiece check valve. All handpieces run, but no water to one handpiece or scaler. No water flow through one handpiece or scaler. Tubing clogged or damaged. Remove handpiece or scaler from tubing and verify water flow from tubing. If no water flow, clean out or replace tubing. If water is present , clean water port in handpiece. If still no water, replace handpiece or scaler. All handpieces run, but do not function properly. Water sputters when handpiece is used. Air in lines. Check for air in coolant water lines. Depress coolant water flush valve button and hold for approximately 45 seconds. Water is leaking into oil/ Handpiece is not sealing at hose connecair separator or water is tion point, causing water to leak into exhaust turned on to low speed hole. handpiece. Check for damaged or missing gasket in handpiece. Replace damaged or missing gaskets. Refer to handpiece manufacture’s documentation. Verify water is shut off to low speed handpiece. Turn water off. With Water toggle Twisted or damaged tubing. in Either position, water pressure at all handpieces and syringe Coolant water control valve (in delivery unit) is too low. is partially clogged. Check: 1/8” blue tubing between water toggle switch and water supply manifold (in delivery unit) for damage, kinks, etc... Replace damage tubing. Reroute tubing to prevent kinking if necessary. Check air / water flow to coolant water control valve Check and replace coolant water control valve if needed. Refer to: Section B Coolant Water Control Valve Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 6/3/13] A-9 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem All handpieces run, but do not function properly. - Continued Symptom Probable Cause Check Correction With Water toggle switch (City/ Water regulator setting is too low. Bottle toggle switch) in CITY position, water pressure at all handpieces and syringe is too low. Twisted or damaged tubing. In BOTTLE position, water pressure is normal. (STATIONARY MODELS ONLY) Check that water regulator (in junction box) output is 30 PSI. Adjust water regulator output pressure to 30 PSI. If necessary, clean or replace regulator. Check: 1/8” blue tubing between water toggle switch and water regulator ( in junction box) for damage, kinks, etc. Replace damaged tubing. Reroute tubing to prevent kinking if necessary. With water toggle switch (City / Water bottle air regulator setting is Bottle toggle switch) in BOTTLE too low. position, water pressure at all handpieces and syringe is too low. Twisted or damaged tubing. In CITY position, water pressure is normal. (STATIONARY MODELS ONLY) Check that water bottle air regulator (in junction box) output is 40 PSI. Adjust water bottle air regulator output pressure to 40 PSI. Check: 1/8” brown tubing between water bottle air regulator (in junction box) and water toggle switch for damage, kinks, etc. Replace damaged tubing. Reroute tubing to prevent kinking if necessary. Replace damaged tubing. Check: 1/8” blue tubing between water bottle cap and water toggle switch for Reroute tubing to prevent kinking if damage, kink, etc. necessary. Master ON/OFF switch is turned off, but kink valves don’t unkink. Coolant air only is not working. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Water bottle gasket leaking, damaged or missing. Check for air leaking from top of water bottle. Replace water bottle gasket. Threads damaged on water bottle. Check threads on water bottle. Replace with new water bottle if threads are damaged. Drive air foot pedal valve is malfunctioning - bleed port is clogged allowing pressure to remain in drive air line. Disconnect 1/4” clear tubing from 1/4” grey foot control tubing (in J-box) and check for residual air pressure indicates bleed port is not working). Replace entire foot control (drive air foot pedal valve is not available). Master on/off switch valve malfunctioning - stuck open. Replace suspect master on/off switch valve with known working switch valve. Replace master on/off valve. Actuator arm out of adjustment. Check kink valve. Adjust kink valve. Refer to Section B: Kink Valve Adjustment Coolant air adjustment valve (on delivery unit) adjusted too low or malfunctioning. Check coolant air adjustment valve. Adjust coolant air adjustment valve; replace if necessary. Damaged or disconnected tubing. Check: 1/8” green tubing between pinch valve and junction box, ALSO between pinch valve and all handpieces for damage and proper connection. Replace damaged tubing. Reconnect any disconnected tubing. All all [Revised: 6/3/13] A-10 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - WHIP Delivery Head Problem Symptom All handpieces run, but do not function properly. - Continued Handpieces work properly; Syringe has no air. LED light not working on scaler or fiber optic handpiece. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 While one handpiece is in use, one or more additional handpieces) run while in holder. Probable Cause Check Correction Handpiece is not stowed properly on tool pad. Check to see if kink valve of unused handpiece is “unkinked”, even though handpiece is in on tool pad. Make sure handpieces are stowed correctly on tool pad. Check if valve of malfunctioning handpiece is defective and stuck open. Inspect handpiece check valve (connected to 1/8” clear tubing for handpiece), to see if it is stuck open or replaced suspect check valve with known working check valve. Replace handpiece check valve. Tube connector malfunctioning. Check for leaks at connection point between handpiece and tube connector. Replace tube connector. Kink valve is malfunctioning. Check to see if kink valve is working properly. Adjust kink valve, replace if necessary. Drive air foot pedal valve is malfunctioning - bleed port is clogged allowing pressure to remain in drive air line. Disconnect 1/4” clear tubing from 1/4” grey foot control tubing (in J-Box) and check for residual air pressure (residual air pressure indicates bleed port is not working). Replace entire foot control (drive air foot pedal valve is not available). Syringe pinch valve adjusted too low or malfunctioning. Check setting of syringe pinch valve. Adjust pinch valve and or replace valve if necessary. Damaged or disconnected tubing. Check 1/8” yellow tubing between syringe and double pinch valve. Replace damaged tubing. Reconnect any disconnected tubing. Kink valve tubing damaged or disconnected. Check kink valve tubing. Replace damaged kink valve tubing. Reconnect any disconnected kink valve tubing. No power. GFCI tripped. Check GFCI. Reset GFCI. LED light not installed properly. Check polarity. Check polarity ( + & - ) connection of LED bulb. Refer to: Section B LED Scaler or Fiber Optic Tubing connection bad. Check tubing connection. Check continuity between tub- Refer to: Section B LED Scaler ing connection and scaler plug. or Fiber Optic Syringe has no air. All all [Revised: 6/3/13] A-11 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart Problem Probable Cause Scaler running intermittently or low power, or not vibrating for no apparent reason. Check Correction Poor power supply connection. Check power supply. Verify VetPro 1000 is plugged into wall and not loose. GFCI tripped. Check GFCI. Reset GFCI. Air pressure not set correctly. Check air pressure. Check air pressure. Refer to: Section B Air Regulator Not drive air. Check drive air adjustment knob. Verify Drive air adjustment knob is all the way open. Tubing. Check tubing continuity. Check continunity in black and orange wires of the tubing. Refer to: Section B Scaler Tubing Check HI resistance. Check HI resistance between the black and orange tubing wires. Refer to: Section B Scaler Tubing Tip not tight enough. Check tip. Verify tip is tightened. Tip must be tightened for scaler operation to work. Tip is worn. Check tip. Tip must be within tolerance as per tip chart for scaler operation to work. Change tip. Potentiometer Harness bad or misadjusted. Check for proper setting. Service tip: if setting is correct move on to Ώ check. If you have 24 V AC or 31 V DC, Check potentiometer for proper resistance sweep of 4 to 4.7K Ώ when turned from Min to Max on Ohmmeter measuring between the white and brown/blue wires on molex. If resistance is not ok, replace potentiometer harness. If resistance is ok, check all wiring and pins for continuity. Repair any wiring that does not pass continuity check. If you do not have 24V AC or 31 V DC Check power supply and air/electric switch for failure. Replace potentiometer harness if power supply or airelectric switch has failed. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Tubing is damaged. Check tubing. Check continuity in black and orange wires of the tubing. Refer to: Section B Scaler Tubing Handpiece is damaged. Swap out handpieces. If scaler operates properly with different handpiece, old one is damaged. Transducer in scaler. Check transducer in scaler. Replace with a known working handpiece. If the replacement handpiece works, then the transducer is bad in the problem handpiece. Return handpiece to Acteon for service or replace with new handpiece. All all [Revised: 6/3/13] A-12 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - Flex Arm Problem Symptom Flex arm will not lock. Flex arm will not lock. Flex arm will not unlock. Flex arm drifts. Excessive rotation. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Probable Cause Check Correction Lock pawls damaged. Inspect lock pawls for damage. Replace lock pawls. Lock cylinder valve (in flex arm) is malfunctioning. Remove 1/8” brown tubing from lock cylinder and check for residual air pressure (residual air pressure indicates bleed port is not working). Replace lock cylinder valve. Unlock button valve(s) (in delivery head) malfunctioning. Without depressing unlock button(s), remove 1/8” brown tubing from unlock button valves and check for air pressure. Replace unlock button valve(s) if air pressure is detected. Lock cylinder energizes, but flex arm will not unlock. Locking pawls (in flex arm) have Check to see if pawls are become loose and have slipped off installed on arm lock cylinder of arm lock cylinder pin. pin. Re-install locking pawls back on arm lock cylinder pin and tighten mounting hardware. Lock cylinder does not energize. Unlock button valve(s) (in delivery head) malfunctioning. While depressing unlock button(s), remove 1/8” brown tubing from unlock button valves and check for air pressure. Replace unlock button valve(s) if air pressure is not detected. Lock cylinder valve (in flex arm) is malfunctioning. While depressing unlock button(s), remove 1/8” brown tubing from lock cylinder valve and check for air pressure. Replace lock cylinder valve if air pressure is detected. Flex arm drifts down. Spring tension jam nut (in flex arm) needs adjusted. Tighten spring tension jam nut. Flex arm drifts up. Spring tension jam nut (in flex arm) needs adjusted. - Loosen spring tension jam nut. Flex arm has too much play. Screws at pivot points need tightened. - Turn set screws at pivot points clockwise. (4) places. Flex arm does not move freely. Screws at pivot points need loosened. - Turn set screws at pivot points counter-clockwise. (4) places. Flex arm can be rotated more than 120°. Rotation stop pin(s) (top of fixed arm) missing or broken. Check for missing or broken stop pins. Replace stop pin(s). Rotation stop screw (top of fixed arm) missing or broken. Check for missing or broken rotation stop screw. Replace rotation stop screw. - All all [Revised: dd/mo/yr] A-13 Always verify model & serial number Back Next Go to Table of Contents Troubleshooting Chart - Compressor Problem Probable Cause Compressor will not start. (MOBILE & SOLO MODELS ONLY) Check Correction Power cord unplugged. Check that power cord is plugged into cart and outlet. On/Off switch is off. Check that the on/off switch is Turn on/off switch on. Verify light comes on. turned on. No power at outlet. Check for voltage at outlet and/or move to another room. Reset circuit breaker. Assure outlet is on dedicated circuit capable of handling cart requirements. Loose wire connection. Check back panel wire connections. Reconnect wires to back panel if loose. Check voltage on circuit breaker, power cord bracket and on/off switch. Pressure Switch Frozen Check Pressure Switch. Replace Pressure Switch. Refer to: Section B Pressure Switch Capacitor. Check Capacitor. Test capacitor. Replace if needed. Refer to Section B: Capacitor Motor/Compressor Frozen Unplug cart. Can you manually move compressor fans? If you are unable to move compressor fans, replace compressor. Refer to: Section B Compressor Check for air leaks. Refer to: Section B Checking for Air Leaks Compressor will not shut off or will recycle often. Air leaks in system and/or (MOBILE & SOLO MODELS ONLY) foot control. Plug power cord into cart and/or outlet. Compressor will not recycle or stalls. (MOBILE & SOLO MODELS ONLY) Room temperature too high. Ambient room temperature. Move to another room. Try running unit. Check Valve. See if check valve is sticking. Spray soapy water on solenoid muffler, if it bubbles while compressor is running, replace check valve. Refer to: Section B Check Valve Compressor makes humming noise and or smells like it is burning. (MOBILE & SOLO MODELS ONLY) To much back pressure. See if check valve is sticking. Clean or replace check valve. Refer to: Section B Check Valve Compressor head runs but will not pressuize to 100 PSI. (MOBILE & SOLO MODELS ONLY) Drain open. Check drain valve to see if open or closed. Close drain valve. Dirty intake filter. Check fresh air intake filter. Replace fresh air intake filter. Refer to: Section B Intake Filter Leak in air line. Check air lines for leaks. Replace and or repair any air lines that are leaking. Leak in air line. Check air lines for leaks. Replace and or repair any air lines that are leaking. Compressor cycles with no air being used. (MOBILE & SOLO MODELS ONLY) Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] A-14 Always verify model & serial number Back Next Go to Table of Contents Section B Testing & Repair © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] Mobile & Solo Models Only Air Water Regulator............................B-2 Water System.....................................B-3 Electrical Box......................................B-4 Pressure Switch, Timer & Solenoid....B-5 Compressor........................................B-7 Intake Filter.........................................B-8 Capacitor............................................B-9 Checking for Air Leaks.....................B-10 Check Valves.................................... B-11 Stationary Models Only Pressure Regulators.........................B-12 Manual Shut-Off Valves....................B-13 Water Toggle Switch.........................B-16 Water Bottle......................................B-17 All Models Coolant Water Flush Button.............B-18 Wet / Dry Foot Control......................B-20 Master On / Off Switch.....................B-22 Flex Arm Lock (Valve)......................B-23 Coolant Water Control (Valve)..........B-26 Kink Valves.......................................B-28 Handpiece Adjustments....................B-30 Delivery Indicators............................B-31 Handpiece Check Valves.................B-32 Air / Oil Separator.............................B-33 Fiber Optic (Optional)....................B-34 Scaler Testing.................................B-35 LED Scaler Testing...........................B-36 B-1 Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Air Regulator & Master Pilot Shut-Off - Function and Location The air regulator provides air to the foot control throttle valve through 1/4” clear tubing, air to the syringe through 1/8” yellow tubing, and air to the in-line regulator through 1/8” brown tubing. This regulator is set at 55 PSI at the factory and should never need adjustment. In Mobile units, condensate from the regulator should drain automatically into the drip pan. Water should evaporate from the drip pan, requiring no clean-up. There is no need for a drip pan in the Solo unit. Air Regulator Master Pilot Shut-Off Valve The in-line regulator provides air to pressurize the water bottles. This regulator is manufactured to deliver 30 PSI and cannot be adjusted. In-line Regulator The master pilot shut-off valve controls air flow to the air regulator. It is controlled by a switch on the unit head. In the “off” position, this switch stops the flow of air to the unit head, foot control, and the water system. Drip Pan (Only in Mobile) Solo Mobile Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] B-2 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Water System - Function and Location The two-bottle water system provides water to the instrument head. The water toggle switch supplies a flow of compressed air to the bottle selected, which maintains the water pressure at a constant 30 PSI. Water Toggle Switch It is normal for there to be residual pressure in both bottles even when the unit is turned off. To remove a bottle for refilling, flip the water toggle switch to the other bottle, then unscrew the deselected bottle slowly to allow the residual pressure to escape. If it is necessary to remove both bottles at the same time, turn the unit off first then drain all the pressure from the storage tank using the drain valve. Water Bottles Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] B-3 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Electrical Box - Function and Location The electrical box contains three receptacles. There are two single-plug receptacles on the top of the box, one for the scaler’s power supply and one for an optioanl fiber optic sytem. These can only be reached with the access panel or cover removed. There is also a dual-plug GFCI receptacle which can be accessed externally. The AC inlet for the unit’s power cord is located at the bottom rear of the electrical box. An on/off switch controls power to the unit. Equipment Alert Tripped GFCI can cause scaler and Fiber Optic on High Speed to stop working. Verify GFCI is not tripped. Receptacle For Scaler and Fiber Optics Accessory GFCI Receptacle Solo On/Off Switch Mobile AC Inlet Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 05/7/09] B-4 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Pressure Switch, Solenoid & Timer - Function and Location The function of the pressure switch is to regulate pressure in the storage tank by turning the compressor on and off. When the pressure in the storage tank reaches 100 PSI (+ / - 5 PSI) , the pressure switch cycles the compressor off. It will cycle on when the pressure in the storage tank drops to 80 PSI (+ / - 5 PSI). The solenoid allows air to escape from the compressor during start up to relieve pressure on the head. The timer allows air to escape for approximately two seconds, which lets the compressor reach full RPM. Then the solenoid closes, redirecting compressed air to the storage tank. The exhaust muffler makes the solenoid operate more quietly. It can be cleaned with a rag and should be replaced annually. Note To read PSI in air storage tank, attach a pressure gauge to the drain port by first removing the drain valve. Solo Solenoid Exhaust Muffler Solenoid Pressure Switch Mobile Timer Timer Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 5/7/09] B-5 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Pressure Switch - Adjustment Before you begin... Remove rear access panel. Refer to Section C Access Procedures Step 1: Run compressor until pressure reaches 100 lbs. Note: Compressor should shut off close to 100 PSI. Adjuster Nut Note To read PSI in air storage tank, attach a pressure gauge to the drain port by first removing the drain valve. VA1464 Step 2: If compressor didn’t shut down at 100 PSI turn nut on adjuster to reset gauge. Models: • Clockwise will incresae reading. • Counter Clockwise will decrease reading. 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 4/3/09] B-6 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Compressor - Function and Location (Including Intake Filter, Cooling Fan, Capacitor and Thermostat) Atmospheric air is drawn in through the intake filter before flowing to the compressor. The intake filter protects the compressor from dust and debris. The filter inside the intake filter housing should be changed annually. The capacitor is a run capacitor. It changes the phase to give more power to the compressor. The oil-less compressor, compresses air to fill the storage tank. Heat is released during this process. The compressor’s duty cycle is 100%, it can run continuously without overheating, but it should not be running often when instruments are not in use. Mobile If you are unable to manually move the fans on the compressor (when power supply is completely shut-down), the compressor head needs replaced. There is a head rebuild kit available. Intake Filter A fan on top of the compressor box helps keep the compressor cool. A thermostat attached to the top of the box turns on the fan when the temperature of the box reaches between 88° F (31° C) and 102° F (39° C). The fan will shut off when the temperature of the box reaches between 60° F (17° C) and 80° F (27° C). Solo Capacitor Thermostat Cooling Fan Capacitor Compressor Intake Filter Cooling Fan Models: Thermostat 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 01/17/11] B-7 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Intake Filter - Replace Step 1: Remove rear access panel. Refer to Section C Access Procedures. Step 2: Remove filter housing from cap by pushing in and turning. Filter Filter Housing Solo Mobile Rear Access Panel VA1465 Step 3: Remove filter and clean by blowing out or replace as needed. Install new filter in housing to cap on compressor head. Install rear access panel. Note: Air Intake Filter should be changed annually. Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 05/07/09] B-8 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Capacitor - Test Step 1: Disconnect power. Access run capacitor in lower compartment on mobile units and under cover of solo units. Step 4: Place meter probes on capacitor connectors. Reverse the leads, this should produce the same reading. Note: Refer to: Section C for access procedures. Step 2: Discharge capacitor by touching screwdrivers to both contacts on the capacitor and to each other. Step 3: Set meter to Ω reading. Meter Reading Status Required Action “O” or “Open” Reading Replace Capacitor Start Low and Increases Capacitor Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 05/07/09] B-9 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Foot Control........................................ B-x Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Checking for Leaks Before you begin... Turn master ON / OFF switch ON and allow unit to pressurize. Checking for Air Leaks... Check Valve, Compressor, and Air Lines A) Disconnect electrical power. B) Remove rear access panel (Mobile) or top cover (Solo & J Box). C) Spray soapy water on air line connections. D) Check delivery head for leaks. Note: If you do not see a leak, check other air line connections by removing front and back molding covers (mobile units only). Refer to Section C Access Procedures. Also refer to Section B Foot Control to check for leaks. Water Bottle Gaskets Junction Box or Solo Unit (if applicable) Check Valves, air and water lines Kink Valves Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 6/4/13] B-10 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Drain, Pressure Relief and Storage Tank Check Valves- Function and Location Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 The storage tank check valve keeps air from flowing back into the compressor. The pressure relief valve protects the storage tank from an overpressure condition in the event of a pressure switch failure. Storage Tank Check Valve The drain valve is used to drain the storage tank of any water that may have condensed there. It also allows the tank to be depressurized for the replacement of lines and other components. Pressure Relief Valve Storage Tank Drain Valve Models: 8001-009 8001-010 VetPro® Solo all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 05/07/09] B-11 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Regulator Adjustments.......................B-1 Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Pressure Regulators - Function and Location The “city” water regulator supplies “city” water to the City/Bottle water toggle switch (thru 1/8” blue tubing). This regulator should be set at 30 PSI to optimize performance. The water bottle regulator supplies distilled water to the toggle switch. This regulator is set at 30 PSI and should never need adjusted. Water Regulator.................. 003-1958-00 Air Regulator....................... 003-1959-00 The air regulator w/gauge provides air to the foot control valve (thru clear dashed tubing) and air to the syringe (thru 1/8” yellow tubing). This regulator should be set at 80 PSI to optimize performance. The regulators are located inside the junction box. “City” Water Regulator Clean regulators by removing tubing and blowing them out with air, then replace tubing. Water Shut-Off Water Bottle Regulator Air Shut-Off Valve 40 20 2 60 3 4 5 0 80 0 1 6 7 Air Regulator Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] 100 8001-005 8001-006 8001-007 all all B-12 all Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Regulator Valve Filters.......................B-3 Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Air, Water & Bottle Regulator - Adjustments (Stationary Units ONLY) To adjust regulator... Decrease A) Pull adjustment knob up to unlock. B) Rotate knob until desired pressure is displayed on gauge. C) Push knob down to lock. Increase Adjustment Knob Unlock Lock Regulator Valve Settings The pressure regulator valves allow you to adjust the air and water pressure that is supplied to the dental unit. Recommended Settings “City” Water Regulator Valve..........30 PSI Air Regulator Valve.........................80 PSI Water Bottle Regulator Valve..........30 PSI (Do not adjust!) Equipment Alert The dental unit has been designed to operate at the recommend settings. Setting the pressure higher / lower than recommended may result in damage to the equipment or diminished performance. Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] 8001-005 8001-006 8001-007 all all B-13 all Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Regulator Adjustments.......................B-1 Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Pressure Regulators - Valve Filters The air and water pressure regulator valves each have a sediment filter to prevent debris from entering the system. To maintain proper air and water flow, these filters should be replaced approximately every three months. Before you begin... Turn off water & air supply to the dental unit by closing both manual shut-off valves. 40 20 60 3 2 4 5 0 80 0 1 6 7 100 40 20 2 60 3 4 5 0 80 0 1 6 7 100 Step 2: Unscrew retainer nut. Remove filter. Filter Step 3: Install new filter. Secure with retainer nut. Retainer Nut Note: Install the filter & retainer nut with the ridged side up (as shown). Filter Cap Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] Step 1: Unscrew filter cap. Step 4: Reinstall filter cap. Note: Use 9/16” wrench. Note: Use 9/16” wrench. 8001-005 8001-006 8001-007 all all B-14 all Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Manual Shut-Off Valves The manual shut-off valves allow you to stop the air and/or water supply at the point of input to the dental unit. This can be done during extended periods of no-use (ex. vacation, holidays, etc.), or in the event of a malfunction. The manual shut-off valves are located in the junction box for Wall / Cabinet mount models and outside the compressor unit on the Solo model. Solo Model Wall / Cabinet Models To shut off water to Dental Unit... Rotate water shut-off valve knob clockwise. Water Shut-Off Valve Air Shut-Off Valve To shut off air to Dental Unit... 40 20 2 60 3 4 5 0 80 0 1 6 Water Shut-Off Valve 7 Rotate air shut-off valve knob clockwise. 100 Compressor Tank Drain Valve Models: 8001-001, -002, -003, -005, -006, -007 & VetPro® Solo Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: dd/mo/yr] B-15 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Water Toggle switch - Function and Location Distilled water is supplied to the toggle switch from the water bottle (thru 1/8” blue tubing). City water is supplied to the toggle switch from the water regulator (thru 1/8” grey tubing). When “City” is selected, city water is supplied to the handpieces, when “Bottle” is selected, distilled water is supplied to the handpieces. Water Selector Replacement ...................... 003-1960-00 Wall Mount Shown The water toggle switch is located on the bottom of the arm next to the water bottle. Note: The outgoing water line from the toggle switch is used for both City and Bottle water. If the toggle leaks on a mounted unit, replace the toggle since the water is routed through it. Selector Switch Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] 8001-005 8001-006 8001-007 all all B-16 all Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Water Bottle - Function and Location The self-contained water system has one, one-liter bottle located on the arm. It is recommended to use only distilled water in the bottle. The water bottle supplies distilled water to the instruments that use water. Air flows from the water bottle air regulator at 30 PSI to pressurize the water bottle. Wall Mount Shown Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] 8001-005 8001-006 8001-007 all all B-17 all Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Coolant Water Flush Button (Valve) - Function and Location The coolant water flush button allows you to purge coolant water thru the handpieces. The Purging Procedure removes debris from the handpiece/syringe tubing. If this procedure is done frequently, it may reduce biofilm buildup on your instruments. Flush Valve Replacement.... 003-1962-00 The coolant water flush button is located under the front of the delivery on the left side. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-18 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Coolant Water Flush Button (Valve) - Flush Procedure To Flush Handpieces... A) B) C) D) E) F) G) Remove all handpieces that use water. Open water needle valve. Turn foot control toggle switch to WET. Hold the handpieces/tubing over a container and press foot control for 30 seconds. Then press and hold flush button for 30 seconds. Repeat (step D) for all handpieces. Press and hold syringe buttons (air & water) for 30 seconds. Install newly disinfected handpieces. Refill water bottle. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-19 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Wet / Dry Foot Control - Function and Location The foot control supplies drive air and air pressure for coolant water to handpieces. When the water toggle on the foot control is set to WET (blue dot), air pressure opens the coolant water control valve allowing coolant water to flow into handpieces. DRY WET Blue Dot Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-20 Always verify model & serial number Back Next Go to Table of Contents Testing & Repair Checking Foot Control To check a foot controller that is leaking.. A) Check for hole or puncture in tubing. B) Check springs, if compressed, stretch them out and reinstall. C) Use soapy water to check o-rings for leaks. Note: Also refer to: Checking for Leaks in Section B Remove for Spring Access Remove for O-ring Access Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 6/10/13] B-21 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Master ON/OFF Switch - Function and Location When the Master On/Off switch is turned on, air passes though the On/ Off switch valve to the pilot valve block which delivers air into the delivery system. The Master On/Off switch is located on front of the delivery panel. VA1369 VA1355 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-22 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Flex Arm Adjustment........................B-13 Pivot Point Adjustment.....................B-14 Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Flex Arm Lock (Valve) - Function and Location The delivery must be pressurized to activate movement of the flex arm. The flex arm will move up at all times, but is restricted from downward movement by a locking pawl inside the arm housing. The arm only moves downward when one of the flex arm buttons are depressed. When either of the buttons are depressed, air flows thru the flex arm unlock button valve to the flex arm lock cylinder (1/8” brown tubing) causing the lock cylinder to extend. When the lock cylinder extends, the locking pawls raise allowing the flex arm to move downward. Flex Arm May Be Raised At Anytime Flex Arm May Be Lowered only when there is pressure in the system and a flex arm button is depressed. One Flex Arm Button is Located on Each Side of Delivery Head Locking Pawl It may be necessary to lift delivery head slightly to disengage lock as downward pressure may prevent the locking pawls from disengaging. Cylinder Operational Test.. A) B) Move flex arm upward, and release; then attempt to move flex arm downward. Observe. Flex arm should move upward freely and stay in position when released. It should not move downward. Depress flex arm button(s) and move flex arm downward; then release button(s). Observe. Flex arm should move downward freely with buttons depressed, and lock in place when buttons are released. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-23 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Flex Arm - Spring Tension Adjustment Step 1: Remove flex arm cover. Step 2: Adjust tension nut to increase or decrease spring tension. Note: Refer to: Section C, Flex Arm Increase Step 3: Raise and lower flex arm; then move flex arm to horizontal position and observe. Flex arm should be easy to move, yet not drift downward. Repeat step 2 and 3 if necessary. Decrease Step 4: Install flex arm cover. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-24 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Flex Arm - Pivot Point Adjustment To Adjust Arms at Pivot Points.. If arms have too much play, tighten set screws (Clockwise). If they do not move freely, loosen set screws (Counter-Clockwise). Pivot Points Remove Bearing Cover to Access 4th Pivot Point, Set Screw Pivot Point Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-25 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Coolant Water Control Valve Check.B-27 Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List..............E-1 Coolant Water Control Valve - Function and Location The coolant water control valve stops the water flow to the needle valves until “Wet” is selected on the foot control toggle and the foot control (valve) is pressed. Air flows to the coolant water control valve and opens the needle valves allowing water to flow to the instruments. The coolant water control valve is located inside the deliver head. VA1355 VA1368 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-26 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Coolant Water Control Valve - Check Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Step 1: Disconnect power. Access instrument head. Note: Refer to: Section C, Access Procedures Step 2: Disconnect orange tuning from coolant water control valve. Depress foot control. Foot Control Tube Out Going Water Supply to Needle Valves Results Incoming Water Supply Step 3: Disconnect tubing from water relay manifold. Depress foot control. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Status Required Action No water when foot control not depressed. Water flow good. Water when foot control is depressed. Water flow good. No air flow when orange tube is disconnected. Tubing clogged or damaged. Change orange tubing. No water flow when manifold tubing is disconnected. Coolant water control valve is bad. Replace coolant water control valve. All all [Revised: 6/10/13] B-27 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Kink Valves - Function and Location When the whip is pulled forward, the spring hub pin pushes the wire actuator down, releasing a plunger that activates the kink valve to relax, allowing air and water flow through the tubing. Kink valves are located inside the delivery head. Kink Valve Replacement..... 003-1961-00 Spring Hub Pin Kink Tubes WHIP Wire Actuator Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-28 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Kink Valves - Adjustment Delivery units use an actuator assembly attached to the kink valve. The actuator contains a normally closed On/Off valve that opens, supplying pilot air to the kink valve, when the instrument is lifted from the instrument pad. The actuator can be adjusted. Kink Valve Replacement..... 003-1961-00 Step 1: Disconnect power. Access instrument head. Note: Refer to: Section C, Access Procedures Step 2: Loosen jam nut and turn the adjustment screw. Counterclockwise to open the valve. Clockwise to close the valve. Jam Nut Adjustment Screw Step 3: Check operation. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 6/10/13] B-29 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Handpiece Adjustments - Function and Location Coolant water adjustment knobs are located on the front panel. Coolant air and drive air adjustment knobs (Pinch Valves) are located on the bottom of the delivery head. The user can adjust the flow of coolant water and drive air to the handpieces, syringe and scaler by turning the knob on the pinch valve. Coolant Water Pinch Valve Coolant Air VA1367 VA1348 Syringe Water Drive Air Syringe Air Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-30 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Delivery Indicators - Function and Location The pressure indicator will be illuminated red when the master on/off switch is in the “on” position and compressed air is available to the unit. The pressure indicator will not be illuminated when there is either no available source of compressed air or the master on/ off switch is in the “off” position. The drive air pressure gauge indicates the drive air pressure of whichever handpiece is in use. If the scaler is being used, the gauge indicates its coolant air pressure. Pressure Indicator Drive Air Pressure Gauge Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-31 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Handpiece Check Valves - Function and Location Check valves are located in the coolant water line, drive air line and the coolant water flush line for each instrument. Check valves keep the flow of air/water from backing into the system and or instrument. Check Valve Dire ctio Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 n of Flow All all [Revised: dd/mo/yr] B-32 Always verify model & serial number Back Next Go to Table of Contents Testing and Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Air / Oil Separator- Cleaning The air/oil separator (exhaust collector) acts as an exhaust muffler and oil collector (gauze). When gauze becomes saturated it must be replaced. Before you begin... Turn master ON / OFF switch OFF. Note User should clean air / oil separator periodically and replace gauze when it becomes saturated. Gauze Cup To clean the air / oil separator cup... A) Unsnap cup. B) Dispose of saturated gauze. C) Disinfect cup. D) Install new gauze, then reinstall cup. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] B-33 Always verify model & serial number Back Next Go to Table of Contents Testing & Repair Access Procedures............................C-1 Tubing & Wire Diagrams.....................D-1 Exploded Views & Parts List...............E-1 Fiber Optic To check voltage... Testing • Verify voltage at power supply connection to optic controller (stablizer) is 9 VDC. • With foot pedal depressed, check voltage on black and white wire connections at optic controller (stablizer). Verify voltage is 2.9 - 4.1 VDC. • Remove instrument, swivel coupler (if equipped) and bulb (light module) from tubing. • Check voltage at wire connectors on tubing end. Verify voltage is 2.9 - 4.1 VDC. Power Supply Check Power Supply Optic Controller (Stablizer) End of Tubing Volltage Check Voltage Checks Shown Note Depress Foot Control to Check Wire Connection Voltage If the voltage is out of spec at the Optic Controller (Stablizer), check the air tubing for air flow. If no air flow, check for a kink in the line. Repair and restore air flow, then recheck voltage again. If voltage is still out of spec, then replace the optic controller. Meter Reading Models: Status Required Action Voltage Within Specs at All three Checks Wiring in Tubing, Power Supply OK, replace Bulb Voltage out of spec at Power Source Replace Power Supply Voltage out of spec at Optic Controller (Stablizer) Replace Optic Controller (Stablizer) Voltage out of spec at tubing end. Replace Tubing. 8001-005, 8001-006, 8001-007, 8001-010 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 11/07/15] B-34 Always verify model & serial number Back Next Go to Table of Contents Testing & Repair To test continuity... Scaler Tubing Set meter to Ω. Check orange wire of molex to the center pin of tubing. Check right side (as shown) pin of tubing to the black wire in molex. Testing Note: Refer to: Section D Wire Diagrams Check To Orange Wire Check To Black Wire Note Only check for HI resistance if scaler is experiencing intermittent or low power. To check HI resistance... • Set ohmmeter for 20 MEG OHM scale. If using a manual setting meter or just “OHMS” if auto ranging meter. • Disconnect handpiece from tubing. • Disconnect molex from module. • Without touching probe leads with fingers, place the meter leads across the orange and black wires in molex. There should be (Open Circuit). Any reading other than this indicates a HI Resistance short in tubing and needs to be replaced. Meter Reading Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 9/10/12] B-35 Status Required Action 0.1 - 1.0 Ohms (Continunity Check) Tubing OK “O” or “Open” Reading (Continunity Check) Replace Tubing Always verify model & serial number Back Next Go to Table of Contents Testing & Repair LED Scaler To check polarity.. Verify + on the LED ring and the handpiece are the same side. Check and Test LED (+) LED (-) To test continuity... Set meter to Ω and check connections. PIN 1 is wired to Black wire of Molex Plug. (Ultrasound Signal) PIN 2 is wired to White wire of Molex Plug. (LED Power) PIN 3 is wired to Blue wire of Molex Plug. (LED Power) PIN 4 is wired to Orange wire of Molex Plug. (Ultrasound Signal) Meter Reading Status Required Action “O” or “Open” Reading (Continunity Check) Replace Scaler Cord 0.1 - 1.0 Ohms (Continunity Check) Scaler Cord OK Voltage within specs when measured at LED Ring (Test Tubing Connections) Handpiece, tubing and module OK Voltage out of specs at LED Ring Pins (Test Tubing Connections) Tubing pin Voltage ok - Replace Handpiece Molex Plug Voltage ok and NOT at Tubing Pins - Replace Tubing Models: To test in the tubing connection... --Set meter to V. With no LED in socket, voltage reading will be approximately 21 VDC. With LED inserted, voltage reading will be approximately 12 or 14 VDC measured at pins on the blue and white wire on molex plug. Note: This requires thin probes to make contact. 8001-005, 8001-006, 8001-007, 8001-010 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 4/26/13] B-36 Always verify model & serial number Back Next Section C Go to Table of Contents © Midmark Corporation 2008 SF-1930 Access Procedures [Revised: 03/10/09] Instrument Head.................................C-2 Junction Box ......................................C-3 Water System (Stationary).................C-4 Flex Arm.............................................C-5 Rear Access Panel.............................C-6 Electrical Box......................................C-7 Shrouds (Front, Back and Top)......... C-8 Enclosure (Black Box)........................C-9 Cover (Solo).....................................C-10 C-1 Back Next Go to Table of Contents VetPro® 5000 Wall / Cabinet Mount Instrument Head Access Step 1: Turn unit master switch off. Remove top cover. Step 2: Remove four screws to access instrument head. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] C-2 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Wall / Cabinet Mount Junction Box Access Step 1: Loosen thumbscrews. Lift cover off. Front Shown Back Shown Thumbscrews Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: dd/mo/yr] 8001-005 8001-006 8001-007 all all C-3 all Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Wall / Cabinet Mount Water System Access Step 1: Unscrew water bottle. Remove screws. Pull cover off. Models: 8001-001 8001-005 8001-002 8001-006 all all all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: dd/mo/yr] C-4 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Wall / Cabinet Mount Flex Arm Access Step 1: Remove two screws and both end caps. Step 2: Remove flex arm top and bottom cover. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] C-5 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Mobile Rear Access Panel Step 1: Remove four screws and rear panel. VA1468 Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] C-6 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Mobile Electrical Box Step 1: Remove four screws and rear panel. VA1469 Step 2: Remove two nuts and washers to remove and electrical cover. Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] C-7 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Mobile Testing and Repair.............................B-1 Step 3: Unscrew and turn top shroud 90 degrees. Shrouds (Front, Back & Top) Note: This will allow you to access screws in top of front and back shrouds. Before you begin.. Unplug unit from wall outlet. Depressuirze the storage tank using the drain valve. Refer to Section B Check Valves. Step 5: Remove back shroud. Step 4: Remove front shroud. Step 1: Unscrew water bottles. VA1470 Step 2: Remove rear access panel. Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] C-8 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Mobile Enclosure Access (Black Box) Step 1: Unscrew and turn top shroud 90 degrees. Note: This will allow you to access screws in top of front shroud. Before you begin... Unplug unit from wall outlet. Depressurize the storage tank using the drain valve. Step 2: Remove front shroud. Note: Four screws on top and on botton of shroud. Step 3: Remove front panel to enclosure (black box). Note: Two screw on each side of panel. VA1483 Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 4/3/09] C-9 Always verify model & serial number Back Next Go to Table of Contents VetPro® Solo Cover Removal Before you begin... Unplug unit from wall outlet. Step 1: Remove eight screws. Remove cover. VA1495 Models: VetPro® Solo Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: dd/mo/yr] C-10 Always verify model & serial number Back Next Section D Go to Table of Contents © Midmark Corporation 2008 SF-1930 Tubing &Wiring Diagrams [Revised: 03/10/09] All Models Instrument Head Tubing.....................D-2 Cabinet / Wall Mount / Table Junction Box Tubing (Cabinet/Wall)...D-3 Water Bottle Tubing (Cabinet/Wall)...D-4 Water Bottle Tubing (Table)................D-6 Electrical Diagram..............................D-9 Mobile Models Water Bottle Tubing............................D-5 Tubing Diagram..................................D-7 Electrical Diagram..............................D-9 Solo Tubing Diagram................................D-10 Electrical Diagram ...........................D-11 D-1 Back Next Go to Table of Contents VetPro® 5000 Instrument Head Tubing Diagram (All Models) Shuttle Valve Models: ALL VetPro 5000 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 9/27/10] D-2 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Junction Box Tubing Diagram (Wall/Cabinet Mount Only) Chip Air (Not Used) 1/8" Blue Instrument Water 1/8" Blue Syringe Tubing Instrument Water Water Bottle Assembly City Water to Water Bottle Assembly Ribbed Side Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: 01/19/11] 8001-005 8001-006 8001-007 all all D-3 all Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Water Bottle Tubing Diagram (Table & Wall/Cabinet Mount Only) Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: 5/21/09] 8001-005 8001-006 8001-007 all all D-4 all Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Water Bottle Tubing Diagram (Mobile) Water Toggle Switch Air From Regulator 30 PSI Water to Delivery Head Check Valve Left Water Bottle Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] Check Valve Right Water Bottle D-5 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Tubing Diagram (Mobile) Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 5/14/12] D-6 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Mobile Model Wire Diagram Models: Note Wire Kit - 002-1465-00 includes all wires in “electrical box” plus timer to pressure switch wire, fan and thermostat wires. 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 7/10/12] D-7 Always verify model & serial number Back Next Go to Table of Contents VetPro® 5000 Stationary Models Wire Diagram Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 8001-003 all all [Revised: 7/10/12] 8001-005 8001-006 8001-007 all all D-8 all Always verify model & serial number Back Next Go to Table of Contents VetPro® Solo Tubing Diagram Models: VetPro® Solo & 8006-001 Serial Numbers: © Midmark Corporation 2008 SF-1930 V759502 thru Present [Revised: 09/27/10] D-9 Always verify model & serial number Back Next Go to Table of Contents VetPro® Solo Wiring Diagram WH WH BK BK WH GN WH WH Power Cord BK WH GN GN Ground WH BK BK GN GN WH BR BL BK GN BK BK Models: VetPro® Solo & 8006-001 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 09/27/10] D-10 Always verify model & serial number Back Next Section E Go to Table of Contents © Midmark Corporation 2008 SF-1930 Exploded Views & Parts Lists [Revised: 03/10/09] XXX-XXXX-XX XXX-XXXX-XX XXX-XXXX-XX E-1 Wall / Cabinet Mount..........................E-2 Mobile Unit.........................................E-3 Solo Unit.............................................E-4 Back Next Go to Table of Contents Vet Pro 5000™ Wall / Cabinet & Table Mount Flex Arm Full Assembly...........E-16 Spring Rod Assembly..............E-17 Flex Arm Fixed Mount.............E-18 Flex Arm Mount.......................E-19 Wall Mount Components..................E-23 Cabinet Mount Components.............E-24 Unit Arm Assembly Wall / Cabinet Mount........................E-21 Unit Arm............................................E-22 Table Mount......................................E-39 Head Componets..............E-5* Lower Head Componets...E-7 Water System Wall / Cabinet Mount...........E-25 Table Mount........................E-40 Water Bottle Assembly.......E-32 Syringe.........E-10 Scaler...........E-11 Fiber Optic Components..................E-12 Athena Handpieces .........................E-13 Midmark Handpieces........................E-14 Handpiece Controls..........................E-20 Athena Handpiece Replacement Components.....................................E-42 Pivot Assembly............E-8 Wall / Cabinet Mount ONLY Junction Box................E-27 Power Supply..............E-28 Air Control Valve.........E-29 Water Control Valve....E-30 Tray Assembly........E-31 Foot Control...........E-26 Models: 8001-(001, -002, -003, -005, -006, -007 Serial Numbers: © Midmark Corporation 2008 SF-1930 * Indicates multiple pages due to a serial number break for the parts illustration. all [Revised: 03/10/09] E-2 Always verify model & serial number Back Next Go to Table of Contents Vet Pro 5000™ Mobile Unit Flex Arm Full Assembly...........E-16 Spring Rod Assembly..............E-17 Flex Arm Fixed Mount.............E-18 Flex Arm Mount.......................E-19 Pivot Assembly............E-7 Tray Assembly........E-31 Shrouds.....E-34 Head Componets..............E-5* Lower Head Componets...E-7 Electrical Box....E-38 Syringe.........E-10 Scaler...........E-11 Water Bottle Assembly.....E-32 Handpiece Controls..........E-20 Fiber Optic components...................E-12 Athena Handpieces .........................E-13 Midmark Handpieces........................E-14 Handpiece Controls..........................E-20 Athena Handpiece Replacement Components.....................................E-42 Air Regulator System......E-37 Frame & Enclosure.....E-33 Compressor.....E-36 Tank, Fan, Fitting &Tubing.......E-35 Foot Control...........E-26 Models: 8001-009 8001-010 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 03/10/09] E-3 Always verify model & serial number Back Next Go to Table of Contents Vet Pro® 5000 Solo Sound Cover & Water Connection Assemblies...E-41 Electrical ...E-44 Compressor and Air Tank Components........E-43* Air Regulator System ..........E-45* Tubing and Fittings......E-15 Models: Serial Numbers: VetPro® Solo 8006-001 0905SOL0001 thru 0910SOL0015 V759502 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 9/27/10] E-4 Always verify model & serial number Back Next Go to Table of Contents 053-2048-00-341 053-2047-00-216 051-1199-00 25 121656 1 Air Control Valve Assembly includes: 2 Trim Nut 3040-0010-74 23 22 113295 4029-2449-03 016-1131-00 21 117660 5051-1209-00 20 6120623 18 19 002-1833-00 7120624 8152105 17 9119905 053-2046-00-216 16 15 029-4018-00 10120388 14 029-4709-00 Models: Serial Numbers: Lock Washer 24 120199 109714 Valve 13 12121650 All V687929 to V753920 © Midmark Corporation 2008 SF-1930 [Revised: 10/27/15] E-5 11115561 Head Components Item Description Qty. 1 Tool Pad 1 2 Upper Shroud 1 3 Screw (#10 - 32 x .38”) 4 4 Air Control Valve 3 5 Stand Off 2 6 Fitting, Flow Adjust 4 7 Pad, Flow Adjust 4 8 Thumb Screw Knob 1 9 Screw (6-32 x 1/4”) 6 10 Nut, Trim (15/32) 1 11 Manual Push Button 3 12 Set Screw (#4-40 x 1/8”) 3 13 Chassis Plate 1 14 Air / Water Separator 1 15 Control Valve Assembly (Refer to: Handpiece Controls) 16 Lower Shroud 17 Valve, C.W. Control 18 Refer to: Scaler 19 Gasket 3 20 Barb Fitting, (10-32 x 1/16”) 2 21 Control Valve 2 22 Elbow, Fitting 1 23 Screw (10-32 x 1/2”) 1 24 Cable Clamp (5/16”) 1 25 Block 1 Always verify model & serial number Ref 1 1 Ref Back Next Go to Table of Contents 29 051-1199-00 121656 053-2047-00-216 Air Control Valve Assembly includes: 1 053-2048-00-341 2 Valve Trim Nut Lock Washer 28 27 120199 26 113295 4029-2449-03 25 109714 5040-0010-109 23 042-0118-01 1 1 3 Screw (#10 - 32 x .38”) 4 4 Air Control Valve 3 5 Screw, Pan Head, (0.190-24X.375 PHIL.) 1 6 Cable Clamp (11/16”) 1 7 Stand Off 2 8 Fitting, Flow Adjust 4 9 Pad, Flow Adjust 4 10 Thumb Screw Knob 1 11 Screw (6-32 x 1/4”) 6 12 Nut, Trim (15/32) 1 13 Manual Push Button 3 14 Set Screw (#4-40 x 1/8”) 3 15 Chassis Plate 1 16 Air / Water Separator 1 17 Control Valve Assembly (Refer to: Handpiece Controls) 18 Lower Shroud 1 19 Valve, C.W. Control 1 20 Scaler Mount 1 21 Screw, (M3 x 5mm) 2 22 Screw, (10-32 x 3/8”) 2 23 Gasket 3 24 Control Valve 2 25 Barb Fitting, (10-32 x 1/16”) 2 26 Elbow, Fitting 1 8001-005, -006, -007, -010 27 Screw (10-32 x 1/2”) 1 28 Cable Clamp (5/16”) 1 V753921 thru V1321184 29 Block 30 Refer to: Scaler 6121656 8120623 21 053-2046-00-216 9120624 20 10152105 19 18 11119905 17 029-4018-00 12120388 16 029-4709-00 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 8001-001, -002, -003, -009 V753921 thru Present [Revised: 10/27/15] 13115561 15 Qty. Upper Shroud 22 002-1833-00 Description 2 30 050-8718-00-216 Item Tool Pad 7051-1209-00 040-0010-141 Head Components with Standard Scaler 1 24 016-1131-00 117660 3040-0010-74 14121650 E-5.1 Always verify model & serial number Ref 1 Ref Back Next Go to Table of Contents 053-2048-00-341 121656 Air Control Valve Assembly includes: 2 053-2047-00-216 051-1199-00 29 1 Trim Nut 3040-0010-74 27 4029-2449-03 26 113295 016-1131-00 25 109714 30 040-0010-141 5040-0010-109 24 6121656 23 7051-1209-00 22 8120623 042-0118-01 21 050-8718-00-216 9120624 20 002-1833-00 10152105 19 11119905 053-2046-00-216 18 029-4018-00 17 12120388 16 029-4709-00 Models: Lock Washer 28 120199 117660 Valve 15 14121650 8001-005, -006, -007, -010 Serial Numbers: © Midmark Corporation 2008 SF-1930 V1321185 thru Present [Revised: 10/27/15] E-6 13115561 Head Components with LED Scaler Item Description Qty. 1 Tool Pad 1 2 Upper Shroud 1 3 Screw (#10 - 32 x .38”) 4 4 Air Control Valve 3 5 Screw, Pan Head, (0.190-24X.375 PHIL.) 1 6 Cable Clamp (11/16”) 1 7 Stand Off 2 8 Fitting, Flow Adjust 4 9 Pad, Flow Adjust 4 10 Thumb Screw Knob 1 11 Screw (6-32 x 1/4”) 6 12 Nut, Trim (15/32) 1 13 Manual Push Button 3 14 Set Screw (#4-40 x 1/8”) 3 15 Chassis Plate 1 16 Air / Water Separator 17 Control Valve Assembly (Refer to: Handpiece Controls) 18 Lower Shroud 1 19 Valve, C.W. Control 1 20 Scaler Mount 1 21 Screw, (M3 x 5mm) 2 22 Screw, (10-32 x 3/8”) 2 23 Barb Fitting, (10-32 x 1/16”) 2 24 Gasket 3 25 Control Valve 2 26 Elbow, Fitting 1 27 Screw (10-32 x 1/2”) 1 28 Cable Clamp (5/16”) 1 29 Block 30 Refer to: Scaler Always verify model & serial number 1 Ref 1 Ref Back Next Go to Table of Contents 1040-0010-159 2030-1812-00-216 3053-1179-00 040-0010-109 8 4042-0046-04 053-1996-00-216 7 Lower Head Components Item 5053-1187-00 040-0010-74 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 6 All all [Revised: 01/27/09] E-7 Description Qty. 1 Screw, PNH (.190-24 x .625) 4 2 Whip Head Pivot Weldment 1 3 Washer 1 4 External Retaining Ring 1 5 Screw, ( #10-32 x 3/8”, PN HD PHLP CDZN) 1 6 Cover, Base, #10 Screw (Sable) 1 7 Swivel Cover 1 8 Screw, PNH, (.190-24 x .375 PHIL) 4 Always verify model & serial number Back Next Go to Table of Contents 120551 24 122161 1122221-50 26 121363 122127 27 25 13 2057-0590-00 3122162 23 152047 Pivot Assembly (3 Places) Item 4120611 21 025-0096-00 5120569 10 13 122174 117479 6120608 20 P11836 120910 18 19 9122177 10122142-2 18 11117660 17 122176 16 122080 040-0010-141 Models: 7122129 22 12122175 15 120959 8029-4533-00 14 13P1829 All Serial Numbers: © Midmark Corporation 2008 SF-1930 Description Qty. 1 Arm Only for Syringe, Scaler, Fiber Optics, High Speed and Low Speed. For Tubing Refer to: Tubing and Fittings 1 2 Whip Pivot 1 3 Set Screw (10-32 x 3/4”) 2 4 Shoulder Screw 1 5 Hub Pivot Pin 1 6 Stop Pin 1 7 Spring Hub Pin 1 8 Actuator Assembly (Includes Items 9 thru 21) 3 9 • Wire Actuator 1 10 • Pivot Pin 1 11 • Washer 2 12 • Actuator Pivot Block 1 13 • Nut (6-32 x 1/4” HEX) 1 14 • Screw (6-32 x 1”) 3 15 • Pin (1/8” x 1/2”) 1 16 • Stop Pin 1 17 • Uni-Clamp (1/8” OD Tube) 2 18 • Pilot Valve 1 19 • Set-Screw (6-32 x 1/4” SO) 3 20 • Spacer Block 1 21 • Extension Spring 1 22 Screw (#10-32 x 3/8”) 2 23 Kink Valve Assembly (Replacement Kit for 1) 1 24 Hub Pivot Block 1 25 Set Screw (10-32 x 1/4”) 2 26 Stop Pin 1 27 Whip Hub 1 Additional Components not show in Illustration all 28 [Revised: 11/21/14] E-8 Stiffer Extension Spring Kit (002-1421-00) Always verify model & serial number 1 Back Next Go to Table of Contents 120551 24 122161 122129 28 1122221-50 26 121363 122127 27 2057-0590-00 25 14 3122162 4120611 Item 23 152047 5025-0113-00 6120569 21 025-0096-00 14 122174 120910 117479 8 20 P11836 16 19 7120608 9122177 1122142-2 18 11117660 17 122176 16 122080 040-0010-141 Pivot Assembly (1 Place - Syringe) 22 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 12122175 15 120959 8029-4533-00 14 13P1829 All Qty. 1 1 2 Whip Pivot 1 3 Set Screw (10-32 x 3/4”) 2 4 Shoulder Screw 1 5 Extension Spring 1 6 Hub Pivot Pin 1 7 Stop Pin 1 8 Actuator Assembly (Includes Items 11 thru 23) 1 9 • Wire Actuator 1 10 • Pivot Pin 1 11 • Washer 2 12 • Actuator Pivot Block 1 13 • Nut (6-32 x 1/4” HEX) 1 14 • Screw (6-32 x 1”) 3 15 • Pin (1/8” x 1/2”) 1 16 • Stop Pin 1 17 • Uni-Clamp (1/8” OD Tube) 2 18 • Pilot Valve 1 19 • Set-Screw (6-32 x 1/4” SO) 3 20 • Spacer Block 1 21 • Extension Spring 1 22 Screw (#10-32 x 3/8”) 2 23 Kink Valve Assembly (Replacement Kit for 1) 1 24 Hub Pivot Block 1 25 Set Screw (10-32 x 1/4”) 2 26 Stop Pin 1 27 Whip Hub 1 28 Spring Hub Pin 1 Additional Components not show in Illustration all [Revised: 11/21/14] Description Arm Only for Syringe, Scaler, Fiber Optics, High Speed and Low Speed. For Tubing Refer to: Tubing and Fittings 29 E-9 Stiffer Extension Spring Kit (002-1421-00) Always verify model & serial number 1 Back Next Go to Table of Contents 2120514 1120796 3016-1029-00 4016-0991-00 5016-0991-04 3 6016-1032-00 18 016-0989-00 7152055 016-1030-00 17 Syringe Item 8120903 9016-0991-01 117660 10016-0990-00 16 DCI# 0084 15 11016-0991-03 12016-0988-00 016-1031-0014 13016-0991-02 Description Qty. 1 Standard Syringe (Includes Items 1-19) 1 2 • Syringe Tip 1 3 • Tip adapter Assembly (DCI# 3065) 1 4 • O-Ring (DCI# 2255) (pkg of 12) 2 5 • O-Ring (DCI# 2202) (pkg of 12) 2 6 • Spring, Syringe Button (DCI# 9670) 1 7 •Button Cartridge Kit (Includes 8 thru 12 not 11) 1 8 •• Button Valve 2 9 •• O-Ring (DCI# 2203) (pkg of 12) 2 10 •• Retaining Ring (DCI# 9601) 2 11 O-Ring (DCI# 2212) (pkg of 12) 2 12 •• Pin (DCI# 9648) 1 13 O-Ring (DCI# 2211) (pkg of 12) 2 14 Syringe Handle (DCI# 3491) 1 15 Barb Fitting (DCI# 0084) (pkg of 10) 2 16 Gasket Sealing 2 17 Pin, Tip Adapter (DCI# 9659) 1 18 Spring, Tip Adapter with Body (DCI# 9677) 1 Items # 19 thru # 23 are Not Shown Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 9/25/15] E-10 19 •• 016-1203-05 - Ultrasonic Stones, Dog Probe Short 1 20 •• 016-1203-06 - Ultrasonic Stones, Cat Probe 1 21 •• 016-1203-07 - Ultrasonic Stones, Dog Probe Long 1 22 016-1502-00 - EMI Supression Core-ACTEON Scaler 1 23 016-1717-00 - ACTEON Autoclavable Tip Box 1 Always verify model & serial number Back Next Go to Table of Contents 016-1203-04 016-1718-01 016-1379-00 4 3016-1203-00 016-1203-03 5 6 016-1380-00 9 8 7 7 2 10 1 2 3 6 5 4 a) 016-1218-00 b) 016-1375-00 Scaler Item 016-1376-00 11 a) 002-1498-00 b) 002-1499-00 a) 016-1378-00 b) 016-1382-00 120769 1 8 a) 002-1002-02 b) 002-1002-05 9 10 Serial Numbers: © Midmark Corporation 2008 SF-1930 Qty. 1 1 2 a) Instrument Only (No Tip) b) LED Instrument Only (No Tip) 1 3 a) Tip, Scaling, Universal (Tip No. 1) b) Tip, Scaling, Voluminous Calculus (Tip No. 2) 1 4 Tip, Scaling, Shallow Pockets (Tip No. 10P) 1 5 Scaler Tip Wrench 3 6 Potentiometer 1 7 Scaler Knob 1 8 Scaler Tubing a) (Std) b) (LED) 1 9 Scaler Control Modular a) (Std) b) (LED 1 10 Air Switch (N.O.) [not part of item 1] 1 11 LED Light (-007, -008 Models) 1 Items # 12 thru # 18 are Not Shown VA1722-1i Models: Description a) Satelec Scaler Kit with Tips & Power Supply Refer to: Scaler Components b) Satelec Scaler Kit with Tips, Power Supply and LED light (-007 & -008 Models Only) Refer to: LED Scaler Components 8001-001, -002, -003, -009 8001-005, -006, -007, -010 V753921 thru Present V753921 thru V1321184 - Standard V1321185 thru Present - LED [Revised: 9/25/15] E-11 12 • 002-1238-00 - Scaler Tips, Ultrasonic, Vet (Includes items 13 thru 15) 13 •• 016-1203-05 - Ultrasonic Stones, Dog Probe Short 1 14 •• 016-1203-06 - Ultrasonic Stones, Cat Probe 1 15 •• 016-1203-07 - Ultrasonic Stones, Dog Probe Long 1 16 016-1502-00 - EMI Supression Core-ACTEON Scaler 1 17 016-1717-00 - ACTEON Autoclavable Tip Box 1 18 016-1589-00 - Tip Wear Guide 1 Always verify model & serial number 1 kit Back Next Go to Table of Contents 4 a) 152021-01 b) 120721-01 1029-2671-00 2120722 3015-1480-00 Fiber Optic Components Item Models: 8001-005, -006, -007, -010 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 11/2/10] E-12 Description Qty. 1 Power Supply 9 VAC 1 2 Lamp 1 3 Fiber Optic Power Pack 1 4 a) Tubing / Lamp (Includes Item # 2) b) Tubing Only 1 Always verify model & serial number Back Next Go to Table of Contents Athena Brand Handpieces 002-1156-00 1 002-1155-00 b a 002-1159-00 6 5 c b a) 016-1204-00 b) 016-1204-01 c) 016-1204-02 9 a) 016-1204-03 b) 016-1204-04 c) 016-1204-05 2 a 8 c 002-1160-01 10 3 11 4 a Models: Serial Numbers: b All [Revised: 6/14/16] a) 016-1204-08 b) 016-1204-09 Description Qty. 1 Low Speed Handpiece 1 2 Prophy Angle 1 3 Prophy Cups (pack of 144) 1 4 Disposable Prophy Angle with Cup: a) 10 pack b) 100 per Box 1 5 High Speed Handpiece 1 6 Fiber Optic High Speed Handpiece Reference: Fiber Optic Components 1 7 Bur Block Kit (Including all Burs, 1 ea) 8 8 a) Round # 2 (Bur) b) Round # 4 (Bur) c) Round # 6 (Bur) 5 ea 9 a) Taper Fissure Crosscut # 701 b) Taper Fissure Crosscut # 701L c) Inverted Cone # 36 5 ea 10 a) Straight Fissure Crosscut # 558 b) Straight Fissure Crosscut # 558L 5 ea 11 a) Diamond Torpedo, Fine, #869LF b) Diamond Football, Fine, #831F 5 Ea 12 064-0031-00 Handpiece Oil Items # 12 and # 13 are not shown Up to V871908 © Midmark Corporation 2008 SF-1930 a) 016-1204-06 b) 016-1204-07 b a a) 002-1279-00 b) 002-1279-02 Athena Handpieces & Maintenance Item 7002-1158-00 002-1157-00 E-13 Always verify model & serial number 1/4 fl. oz. Back Next Go to Table of Contents Midmark Brand Handpieces 002-1277-00 1 2 a) 002-1279-00 b) 002-1279-02 5002-1275-00 016-1362-0018 3002-1160-01 4002-1159-00 20016-1309-00 016-1310-0017 002-1276-00 8002-1994-00 12 13 10016-1728-00 14 6 016-1312-0019 Midmark Handpieces & Maintenance a) 016-1308-00 a) 002-1292-00 a) 002-1293-00 7002-1996-00 15 a) 002-1294-00 11016-1729-00 16 21016-1311-00 a) 016-1291-00 9002-1995-00 VA1608 Item Description Qty. 1 Lowspeed Instrument 1 2 Disposable Prophy Angle with Cup: a) 10 pack b) 100 per box 1 3 Prophy Cups (pack of 144) 1 4 Prophy Angle 1 5 Highspeed Instrument 1 6 Fiber Optic Instrument Reference: Fiber Optic Components 1 7 Kit, Handpiece and Coupler, High speed FO swivel (Includes items 8 & 9) 1 8 Kit, handpiece, High speed FO Swivel 1 9 Kit, Coupler, High Speed FO Swivel 1 10 Wrench, Swivel Coupler 1 11 Conditioner Nozzle, Swivel Handpiece 1 12 5-Hole Replacement Gasket 1 13 Turbine *Includes chuck and item # 20 1 14 Chuck *Includes items # 20 & # 21 1 15 Head Cap * Includes items # 17 & # 20 1 16 Lowspeed Swivel Adapter * Includes items # 12 and #18 1 17 O-Ring 1 18 O-Ring 1 19 Wave Spring 1 20 Head Cap Wrench 1 21 Spindle Cleaning Tool 1 Items 22 thru 25 Not Shown Models: Serial Numbers: All V871909 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 6/14/16] E-14 22 002-1295-00 Water Spray Tool 1 23 002-1432-00 Handpiece Conditioner 1 24 053-2259-00 Conditioner Nozzles 3 25 016-1731-00 Kit, O-ring, Swivel Coupler 1 Always verify model & serial number Back Next Go to Table of Contents Midmark Brand Handpieces 2 a) 016-1204-00 b) 016-1204-01 c) 016-1204-02 3 a) 016-1204-03 b) 016-1204-04 c) 016-1204-05 a b c a c b 1002-1158-00 4 a) 016-1204-06 b) 016-1204-07 5 a) 016-1204-08 b) 016-1204-09 a b Midmark Handpieces & Maintenance Item a Models: Serial Numbers: b All V871909 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 4/19/16] E-14.1 Description Qty. 1 Bur Block Kit (Including all Burs, 1 ea) 2 a) Round # 2 (Bur) b) Round # 4 (Bur) c) Round # 6 (Bur) 5 ea 3 a) Taper Fissure Crosscut # 701 b) Taper Fissure Crosscut # 701L c) Inverted Cone # 36 5 ea 4 a) Straight Fissure Crosscut # 558 b) Straight Fissure Crosscut # 558L 5 ea 5 a) Diamond Torpedo, Fine, #869LF b) Diamond Football, Fine, #831F 5 Ea Always verify model & serial number 8 Back Back Next Next Go Go to to Table Table of of Contents Contents 109714 1 014-0598-00 2 113295 4 a) 117739 b) 117481 5 117479 3 117482 a) 120584-2 6 151914-01 14 177524 117349 15 16 17 Tubing and Fittings Item 117660 a) 177531 b) 177523 c) 177529 d) 177530 e) 177528 f) 177551 7 117698 8 120609 9 10 120623 a) 177606 b) 275519 11 117480 a) S059-00118 b) 029-3069-00 a) 122743 18 b) 014-0684-00 12 13 19 117477 20 Note All tubing must be ordered by the foot. Therefore, the quantity ordered is the amount of feet of tubing needed. Example: ordering an quantity of 2 would be ordering two feet of tubing. AR = As Required. Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 2/17/16] E-15 Description Qty. 1 Connector (#10-32 to 1/16” barb, 1/8” OD tube) AR 2 Control Valve Fitting (#10-32 male & female thds.) AR 3 Barbed Union Fitting (1/8” to 1/8” barb) AR 4 Barbed Tee Fitting ([1] 1/16” barb & [2] 1/8” barb) AR 5 Uni-Clamp (1/8” OD Tube) AR 6 Barbed Fitting a) (1/16” barb & 1/8” barb) b) (1/16” barb x 1/16” barb) AR 7 Sealing Gasket AR 8 Check Valve (1/8” OD Tube) AR 9 Bearing Sleeve AR 10 Tubing (1/8” OD x 1/16 ID) a) Red b) Blue c) Clear d) Yellow e) Purple (Solo) f) Brown AR 11 Flow Adjust Fitting AR 12 Tubing (3/16” OD x 1/8 ID) (a) Clear {80 shore} (b) Clear {90 shore} AR 13 Clamp Sleeve (1/4”) AR 14 Tubing Pin (Plated) AR 15 Handpiece Tubing (4 Port Straight With Tubes) and Arm Assembly for Low Speed and High Speed AR 16 Blue Tubing (1/4” x .159) AR 17 Connector (10-32 x 1/8”) AR 18 3-Way Tee a) [3] barbs for .170” I.D. hose b) [2] barbs for .170” I.D. & [1] for 3/16” I.D. hose AR 19 Handpiece Tubing Only (4-hole) a) Handpiece b) Syringe (INTL) AR 20 Tee, 1/16” Barb AR 21 Not Shown Fiber Optic Tubing with Lamp - 152021-01 Fiber Optic Tubing Only - 120721-01 Note: Arms not included, For Arms Refer to: Pivot Assembly AR 22 Not Shown - 057-0734-00 Handpiece Nut (sleeve) 4 Port (pass) AR VA1399 Always verify model & serial number Back Next Go to Table of Contents a) 021-0038-50 b) 021-0038-52 2002-1021-00 1 10 3042-0065-00 8 4057-0618-00 2 5 3 2 Flex Arm Full Assembly 029-2428-00 - Long 24” (-001, -002, 005, -006) 029-2888-00 - Short 16” (-003, -009, -007, -010) 4 2 Item 6 7053-1179-00 040-006-99 9 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 8042-0056-04 All all [Revised: 10/27/11] E-16 Description Qty. 1 • Refer to: Spring Rod Assembly 2 • End Cap Assembly 3 • Klipring 4 • Clevis Pin 5 • Refer to: Flex Arm Fixed Mount Ref 6 • Refer to: Flex Arm Mount Ref 7 • Washer 1 8 • 1 1/8” ID x 1 1/8” External Retaining Ring 1 9 • Screw (#6-32 x 1/2”) 2 10 • Flex Arm Cover a) Long (24”) b) Short (16”) 1 Always verify model & serial number Ref 1 set 4 2 Back Next Go to Table of Contents 11 117418 a) 117612 b) 117612-2 a) 057-0644-00 b) 057-0728-00 051-0906-00 10 1117415 9 2117744 8 3 a) 025-0070-00 b) 025-0076-00 a) 052-0356-00 b) 052-0356-01 7 4 9 a) 021-0039-00 b) 021-0039-52 Spring Rod Assembly Item 5045-0001-107 6041-0500-04 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 10/8/2012] E-17 Description Qty. 1 Sleeve 1 2 Friction Pad 2 3 Flex Arm Tube a) Long (24”) b) Short (16”) 1 4 Flex Arm Tube Weldment a) Long (24”) b) Short (16”) 1 5 Washer (.516 x 3/4” x .060) 1 6 Hex Nut (1/2” x .516) 1 7 Die Spring, Flex Arm a) Long (24”) b) Short (16”) 1 8 Flex Arm Rod 1 9 Spacer, Flex Arm a) Long (24”) b) Short (16”) 2 10 Sleeve a) Long (24”) b) Short (16”) 11 Washer (1” OD x .516 ID) Always verify model & serial number 1 Back Next Go to Table of Contents 3 2 1057-0618-00 2042-0065-00 3016-0076-06 050-4764-00 11 3 4057-0620-00 5057-0550-00 3 057-0051-00 12 7 15 6052-0357-00 053-1187-00 10 7016-0392-13 040-0010-87 9 8057-0608-00 Flex Arm Fixed Mount Assembly Item Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: dd/mo/yr] E-18 Description Qty. 1 Pivot Pin 1 2 Klipring 2 3 Bushings 4 4 Pin Knurled (1/4”) 1 5 Link Bushing 1 6 Arm Mounting, Fixed 1 7 Dual Flange Bearing 2 8 Pin Knurled (3/8”) 1 9 Bolt (10-32 x 1/4”) 1 10 Screw BaseCover 1 11 Link 2 12 Link Stop 1 Always verify model & serial number Back Next Go to Table of Contents 118071-2 25 118069-2 27 121506 26 1118100 1 2118073 3117575-2 117409-2 24 4117576-2 7 057-0618-00 23 5042-0065-00 016-0076-06 22 5 6118154-3 057-0608-00 21 7103205 4 8118070-2 20 117510 5 19 P11836 16 18 109714 10040-0010-98 9016-0392-13 16 17118072 16117660 12040-0010-87 15113295 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 052-0358-50 14 13053-1187-00 All all [Revised: dd/mo/yr] E-19 11117577 Flex Arm Mount Item Description Qty. 1 Screw (5-40 x 1/4”) 2 2 Stop Plate 1 3 Pawl Arm Lock, Left 1 4 Pawl Arm Lock, Right 1 5 Klipring 4 6 Spring Rod Pin 1 7 Screw (6-32 x 3/16”) 4 8 Bracket Pawl, Pivot Right 1 9 Flange Bearing 2 10 Pan HD Screw (10-32 x 3/8”) 2 11 Latch, Block 1 12 Bolt (10-32 x 1/4”) 1 13 Cover, Base Screw, # 10 1 14 Movable, Flex Arm 1 15 Control, Valve Fitting 1 16 Gasket 2 17 Air Cylinder Mount 1 18 Barb Fitting (10-32 x 1/16”) 1 19 Set Screw (6/32” x 1/4”) 1 20 Cylinder 1 21 Knurled Pin (3/8”) 1 22 Bushings 2 23 Pivot Pin (1/4”) 1 24 Air Cylinder Pin 1 25 Bracket, Pawl, Pivot Left 1 26 Dowel Pin (1/8” x 5/8”) 1 27 Pawl, Plated 1 Always verify model & serial number Back Next Go to Table of Contents 045-0001-130 117235 118940 14120154 13 15029-4521-00 12 122146 119905 17 16120591 11 10 3 115561 9 8 121650 7 117489 Handpiece Controls 120169 10 5 053-1165-01 3120388 4 Models: Serial Numbers: 11 6 120612 1061-1001-00 2 All V700471 thru V1321184 © Midmark Corporation 2008 SF-1930 [Revised: 2/17/16] E-20 Item Description Qty. 1 Controls Label, VetPro® 5000 2 Refer to: Scaler & Syringe 3 Trim Nut (15/32”) 2 4 Knob, Fluted Control, Blue 3 5 Valve, Toggle, 3-Way 1 6 Screw 2 7 Indicator 1 8 Set Screw (#4-40 x .125) 1 9 Manual Push Button 1 10 Screw 3 11 Spacer, Top Cover (Front) 2 12 Control Valve 1 13 Pressure Gauge 1 14 Screw, Soc Head 1 15 Syringe Spring Block Assembly (screw, spring & block) 1 16 Syringe Spray Block 1 17 Washer (.164) 1 Always verify model & serial number 1 Ref Back Next Go to Table of Contents 045-0001-130 117235 118940 14120591 15029-5687-00 13 16025-0113-00 12 122146 119905 17 18120959 11 10 3 115561 9 121650 117489 8 7 Handpiece Controls Item 2 Refer to: Scaler & Syringe 3 Trim Nut (15/32”) 2 4 Knob, Fluted Control, Blue 3 5 Valve, Toggle, 3-Way 1 6 Screw 2 7 Indicator 1 8 Set Screw (#4-40 x .125) 1 9 Manual Push Button 1 10 Screw 3 11 Spacer, Top Cover (Front) 2 12 Control Valve 1 13 Pressure Gauge 1 14 Syringe Spray Block 1 15 1 All Syringe Spring Block Assembly (screw, spring & block) 16 Extension Spring 1 V1321185 thru Present 17 Washer (.164) 1 18 Screw (6-32 x 1.00”) 1 11 6 10 5 053-1165-01 Models: Serial Numbers: Qty. Controls Label, VetPro® 5000 120612 120169 Description 1 © Midmark Corporation 2008 SF-1930 3120388 4 1061-1001-00 2 [Revised: 2/17/16] E-20.1 Always verify model & serial number 1 Ref Back Next Go to Table of Contents 8053-1218-01 1030-1810-00-216 7 016-0856-02 016-0837-00 6 122348 5 7 050-7663-00 4 040-0010-126 040-0250-07 3 2 Wall / Cabinet - Arm Assembly Item Models: 8001-001 Serial Numbers: © Midmark Corporation 2008 SF-1930 8001-005 all [Revised: dd/mo/yr] all 8001-002 all 8001-006 all E-21 Description Qty. 1 Unit Arm Weldment 1 2 Bolt (1/4-20 x 1/2”) (Cabinet Mount Only) 1 3 Cabinet Mount Hard Stop (Cabinet Mount Only) 1 4 Set Screw (.190-32 x 1/4”) 1 5 Dowel Pin 2 6 Slotted Bearing 1 7 Needle Bearing 2 8 Joint Cover 1 Always verify model & serial number Back Next Go to Table of Contents 121428 7 1053-1218-01 2 2040-0010-167 6 3057-1089-00 057-1090-00 016-1569-14 6 5 4030-1811-00-216 2 7 Unit Arm Assembly Item Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 Description Qty. 1 Joint Cover 1 2 Set Screw (#10-32 x 1/4”) 3 3 Shaft, Internal Pivot 1 All 4 Whip Support Arm Weldment 1 5 Bearing (1 1/8” ID x 1 9/32” OD) 1 all 6 Shaft, Internal Pivot 1 7 Screw (10-32 x 1/4”) SS Nylon Tip 1 [Revised: 2/13/15] E-22 Always verify model & serial number Back Next Go to Table of Contents 152469-50 121647-01 11 10 6 029-2887-00 108850 053-1281-00 120233-50 9 8 7 6 1106202 2101317 3053-1242-00 Wall Mount Assembly Item 040-0006-98 Models: 5 4050-5404-50 8001-001 8001-005 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 3/12/12] E-23 Description Qty. 1 Washer (.799 OD x .315 ID) 8 2 Lag Bolt (5/16” x 2 1/2”) 8 3 Track Shim 2 4 Umbilical Retainer 1 5 Screw Pan Head (0.138-32 X 0.375) 2 6 Panel Screw (# 10-32 x .38) 6 7 Bearing Mount Cover 1 8 Screw (1/4-20 x 1”) 4 9 Bearing Mount Assembly 1 10 Wall Mount Cover 1 11 Wall Mount Frame 1 12 Wall Mount Loose Part Kit (002-1417-00 [includes items 1, 2, 5, 6 & 8) 1 Always verify model & serial number Back Next Go to Table of Contents 050-7681-00-216 029-2887-00 053-1281-00 120233-50 8 7 6 5 1053-1242-00 2050-5404-50 3 4 040-0006-98 108850 Cabinet Mount Assembly Item Models: 8001-002 8001-006 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 01/05/11] E-24 Description Qty. 1 Track Shim 2 2 Umbilical Retainer 1 3 Screw Pan Head (0.138-32 X 0.375) 2 4 Screw (1/4-20 x 1”) 4 5 Panel Screw (#10-32 x .38) 4 6 Bearing Mount Cover 1 7 Bearing Mount Assembly 1 8 Cabinet Backer Plate 1 9 Cabinet Mount Loose Part Kit (002-1418-00 [includes items 3, 4 & 5) 1 Always verify model & serial number Back Next Go to Table of Contents 1120385 1 11053-1828-00 5 2002-1709-00 050-5402-5010 5 3117481 053-1463-00 9 4053-1280-00 5040-0010-109 5 6014-0176-52 8 117482 177524 7 Wall / Cabinet Mount Water System Item Models: 8001-001 Serial Numbers: © Midmark Corporation 2008 SF-1930 all [Revised: 8/29/13] 8001-005 all 8001-002 all 8001-006 all E-25 Description Qty. 1 Phillps Pan HD Screw, (8-32 x 1/2”) 2 2 Toggle Switch Assembly with RH Barb 1 3 Barb Fitting (1/6” to 1/6”) 2 4 Water Bottle Cover 1 5 Screw, (.190 x .375) Philps 4 6 O-Ring 1 7 Tubing (1/4” OD x .159 ID) 1 8 Barbed Union Fitting 1 9 Cap, Bottle 1 10 Bottle Mount Bracket 1 11 Water Bottle 1 Always verify model & serial number Back Next Go to Table of Contents 1002-0934-01 2 19 DP# R-F1212-2MK DP# R-F1200-2 3 DP# R-F1200-4MK 4 DP# R-F1200-3B 5 DP# R-F1200-3C Note DP #’ s are Parts Warehouse part numbers. 6 18016-1078-00 7 053-1709-00 17 DP# RF1081 DP# RF1025 Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 14 13 All all [Revised: 05/10] E-26 Qty. 1 2 • Dome 1 3 • Retainer Ring, Dome 1 4 • Spring, Dome 1 5 • Valve Stem 1 6 • Spring, Conical 1 7 • Valve 1 8 • Barbed Fitting (3/16”) 4 9 9 • O-ring 2 10 • Cartridge, Valve Stem 2 11 • O-ring 1 11 12 • Screw (# 6 x 1/2”) 4 13 • Rubber Foot 5 14 • Screw (# 4-40 x 5/16”) 2 15 • Screw (# 4 x 1/2”) 16 • Tubing, Foot Control (Specify Length) DP# O-2008.1 DP# R-F1200-3D DP# O-2012.1 12 15 Description 1 DP# P-1898 10 10 Item Foot Control with Water On/Off Toggle [4 Port] (Includes Item # 2 thru 19) 9 16 Foot Control (DP) 1 8 016-1079-00 DP# R-F12100-3A DP# RF1024 DP# R-F1200-5 4 AR 17 • Wet / Toggle Assembly (includes item 18) 1 18 • • Toggle Lever 1 19 • Valve Shroud 1 20 •• Not Shown Items # 20 thru # 23 002-1001-00, Foot Control Connections Includes Items # 21 thru # 23 1 21 •• 11749 - Uni Clamp (1/8” OD) 6 22 •• 117481 - Barb Fitting (1/16” x 1/16”) 3 23 •• 014-0542-01 - Barb Fitting (3/16” x 3/16”) 2 Always verify model & serial number Back Next Go to Table of Contents 1029-4696-00 029-4554-00 2 3122394-01 4153606 040-0010-36 16 122390-2 5121971 15 117358 002-1722-00 17 6153037 14 7120236-00 8120227-00 002-1633-00 029-2631-00 13 12 120997 Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 11 9121872-00 029-2632-00 8001-002 8001-003 all all [Revised: 9/3/13] 10 8001-005 8001-006 8001-007 all all E-27 all Junction Box Assembly Item Description Qty. 1 Junction Box Assembly 1 2 Umbilical Assembly 1 3 J-Box Cover 4 Refer to: Power Supply Assembly 5 “U” Fastener 4 6 Thumbscrew 4 7 1/2” Plug Button 1 8 3/4” Plug Button 1 9 1” Hole Plug 1 10 Power Cord Cover Plate 1 11 Wing Nut 2 12 J-Box Frame Assembly, Large 13 Refer to: Air Control Valve Ref 14 Refer to: Water Control Valve Ref 15 Nut (10-32) 2 16 Umbilical Retainer Bracket 1 17 Screw (10-32 x 5/16”) 2 18 Junction Box Loose Parts Kit (002-1420-00 [includes lag screws and 1/8” uni-clamps]) 1 Always verify model & serial number 1 Ref 1 Back Next Go to Table of Contents 1040-0010-47 2050-4874-50 3 22 a) 015-1476-00 b) 015-1511-00 3122357 4061-0794-00 015-0591-02 5015-1259-01 19 029-2513-50 6015-0346-01 18 a) 123108-01 b) 015-1510-01 015-1415-00 20 7015-1410-00 21015-0591-01 17 8015-1408-00 117477 16 117479 9045-0001-49 15 177531 10015-0002-08 14 109714 Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 13 8001-002 all [Revised: dd/mo/yr] 11041-0040-00 12117660 8001-003 all 8001-005 8001-006 8001-007 all all E-28 all Power Supply Assembly Item Description Qty. 1 Screw 2 2 Power Supply Cover 1 3 Keps Lock Nut 5 4 Fuse Labels 2 5 Fuse Holder Assembly 2 6 Fuse 2 7 Circuit Breaker 1 8 Pressure Switch 1 9 Washer 1 10 Strain Relief Busing 1 11 Locknut 1 12 Gasket 1 13 Barb Fitting 14 Red Tubing (Sold by the Foot) 15 Uni-Clamp 1 16 Barb “T” Fitting 1 17 Nut - Press to Reset 1 18 Power Cord Assembly a)115V Only b) 230V Only (Not Shown) 1 19 Power Supply Chassis Assembly 1 20 Mate-N-Lock Connector Cap 1 21 Mate-N-Lock Connector Cap 2 22 Transformer (300W) a) 115V Only b) 230V Only 1 Always verify model & serial number 1 AR Back Next Go to Table of Contents 1002-1633-00 050-4816-00 117662 002-0768-00 2145756 24 3109714 23 4117660 5117352 26 7S059-00155 6117351 22 4 22 25 8014-0553-00 Air Control Valve 6 2 25016-0980-00 9177531 122841 21 109714 1176600 122159 117351 19 10117479 18 11121275 20 17 053-1166-00 16 15 014-0176-45 057-0606-00 Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 12029-2535-00 3 10 8001-002 all [Revised: 2/22/16] 13053-1167-00 14 8001-003 all 8001-005 8001-006 8001-007 all all E-29 all Item Description Qty. 1 Air Control Assembly (Includes Items 1 thru 23 except for # 11) 1 2 • Air Regulator 1 3 • Barb Fitting 4 4 • Gasket 10 5 • Fitting 3 6 • Brass Plug 7 • Tubing Clear (5/16” O.D.) (Sold by the foot) 8 • Barbed Fitting (3/16” x 1/8”) 9 • Red Tubing (Sold by the foot) 10 • Uni-Clamp 2 11 Stop Valve 1 12 • Master Shut-Off Valve Assembly (Includes Items -13 thru 18) 1 13 • • MSO Filter Housing 1 14 • • Filter Nut 1 15 • • O-Ring 1 16 • • MSO Filter - 40 Micron 1 17 • Brass Plug (Not Used) 1 18 • Gasket 2 19 • Barb Fitting 4 20 • Air Label 1 21 • Round Pressure Gauge 1 22 • Fittings ( Includes Items 3 thru 6) 2 23 • Pipe Plug 2 24 • Regulator Mounting Plate 1 25 Diaphragm 1 26 Water Bottle Air Regulator 1 Always verify model & serial number 7 AR 1 AR Back Next Go to Table of Contents 15 117660 16 109714 18 117351 17177531 10117662 117352 20016-0980-00 12 14117477 9145349 122841 13117352 11 122160 19 Water Control Valve Assembly 002-1722-00 (Items 1-19) 8 P16629 Item 7 117351 1176600 6 1029-2535-00 053-1166-00 014-0176-45 5 4 3 057-0606-00 053-1167-00 Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 8001-002 all [Revised: 2/22/16] 8001-003 all 2 8001-005 8001-006 8001-007 all all E-30 all Description Qty. 1 Master Shut-Off Valve Assembly (Includes Items 2 thru 7) 1 2 • MSO Filter Housing 1 3 • Filter Nut 1 4 • O-Ring 1 5 • MSO Filter - 40 Micron 1 6 • Gasket 2 7 • Brass Plug 2 8 Nipple (#042-0024-00) 1 9 Water Regulator 1 10 Pipe Plug 1 11 Round Pressure Gauge 1 12 Fitting 1 13 Uni-Clamp 1 14 Barb T Fitting 1 15 Gasket 3 16 Barb Fitting 1 17 Red Tubing 1 18 Brass Plug 2 19 Water Label 1 20 Diaphragm 1 Always verify model & serial number Back Next Go to Table of Contents 1116599 14 119905 2120613-01 120612 13 3057-1091-00-216 4040-0010-108 12 120617-50 5119458 11 120585-2 6119462 5 5 6 7120579 5 7 5 5 5 6 5 9 121079 Models: 8001-001 Serial Numbers: all © Midmark Corporation 2008 SF-1930 Item 6 8120580-50 8 8001-002 all [Revised: dd/mo/yr] 8001-003 all 9120612 10 8001-005 8001-006 8001-007 all all E-31 Whip Unit Instrument Tray Assembly 029-4531-00-216 all Description Qty. 1 Tray 1 2 Tray Support (9 5/8” x 13 5/8”) 1 3 Hub, Instrument Tray, Vet 1 4 Screw (.190-32 x .625) 4 5 Washer (1 1/8” x 5/8”) 8 6 Needle Bearing (Head) 4 7 Bearing, Tray Arm 2 8 Cap, Tray Arm Bearing 2 9 Screw 6 10 Arm, Instrument Tray 1 11 Pin, Tray Arm 1 12 Plate, Tray Support 1 13 Screw 4 14 Screw 4 Always verify model & serial number Back Next Go to Table of Contents 040-0250-133 9 120213702 8 20227801 10 053-1463-00 2117481 7 014-0176-52 117482 3053-1828-00 6 5 Water Bottle Assembly Item 4177524 Models: Serial Numbers: 8001-009 8001-010 V700471 thru Present V722147 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 01/05/11] E-32 Description Qty. 1 Water Bottle Bracket 1 2 Barbed Union Fitting 4 3 Water Bottles 2 4 Tubing (1/4” OD x .159 ID) 2 5 Barbed Union Fitting 2 6 O-Ring 2 7 Cap, Bottle 2 8 8-32 Cap Screw 4 9 Hex Head Whiz Lock (1/4-20 x 1/2”) 2 10 Water Toggle Valve (Refer to shrouds exploded view page elsewhere) Always verify model & serial number Ref Back Next Go to Table of Contents 117977 120227803 24 24015802 17 4016-0856-02 22 62977002 5016-0837-00 730195900 4 21 62500451 62949404 340158702 23 10572500 620227100 Frame & Enclosure 20 40158102 Item 19 865959903 18 10573400 040-0250-133 10588800 940158302 24 1 17 1020213802 16 1 1162949406 10572900 15 PVV50525 Models: Serial Numbers: 14 040-0500-35 13 8001-009 8001-010 V700471 thru Present V722147 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 6/20/12] 1210588900 Description Qty. 1 Cap Screw (10-32) 10 2 Handle Bracket 1 3 Rear Handle Weldment 1 4 Needle Bearing 2 5 Bearing, Slotted Sleeve 1 6 Boss Post Assembly 1 7 Back Panel, Enclosure 1 8 Screw, Self Drilling (1/4-14 x 3/4”) 4 9 Enclosure , Compressor 1 10 Foot Pedal Bracket 1 11 Nut (1/2”-13) 4 12 Non-Locking Caster 2 13 Button Head Screw (1/2”-13) 4 14 Drain Valve 1 15 Panel Mount 1 16 Locking Caster 2 17 Hex Head Whiz Lock (1/4-20 x 1/2”) 10 18 Drip Pan 1 19 Post Assembly 1 20 Nut, PEM (AEKS8-420-165) OPEN END 6 21 Setscrew (10-32 X 1/4”) 2 22 Dowel Pin (.188 OD x .625 L) 2 23 Gasket 1 24 Nut, PEM (10-32) 6 Sound Foam Not Shown (Inside Compressor Enclosure) 40158502 - Front, 40158504 - Left, 40158503 - Right, 40158505 - Back *Note - Back faces enclosure (black box) back opening (# 7). E-33 Always verify model & serial number Back Next Go to Table of Contents 140158000 6 40157800 220227802 7 362600128 2 10575000 6 2 2 3 3 2 2 Shrouds VA1477 20213302 440157900 5 Models: Serial Numbers: 8001-009 8001-010 V700471 thru Present V722147 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 06/11/09] E-34 Item Description 1 Front Shroud 1 2 Cap Screw (10-32) 18 3 Washer, Flat 18 4 Rear Shroud 1 5 Access Panel 1 6 Water Toggle Valve 1 7 Top Shroud 1 8 Not Shown - PN 65962401 Weather Stripping Trim between Shrouds by Water Bottles - (Sold by Inch) Always verify model & serial number Qty. AR Back Next Go to Table of Contents 77000092 20224305 24 62900918 10589900 20214200 162982202 25 265967000 24 23 310589600 420224306 22 21 520224302 20 30193601 620224303 19 040-0250-133 62500176 710589600 18 10597500 20231200 Item 877005020 1 2 Check Valve 1 3 Street Tee (1/4” NPT) 1 4 Adapter (1/4” MNPT - 1/4” FNPT) 2 5 Hose Tank to Switch 1 6 Hose Compressor to Tank 1 7 Street Tee (1/4 NPT) 1 8 Pressure Relief Valve 1 9 Fan 1 10 Nut, Pem (6-32) 4 11 Drain Hose 12 Refer to: Electrical Box Assembly Ref 13 Refer to: Air Regulator System Assembly Ref 14 Nut 1 15 Intake Filter ( Replacement Filter Only) 1 16 Solenoid (includes fitting and filter) (*Filter only order PN - 002-1143-00) 1 17 Timer, Delay 1 18 Pan Head Screw (6-32 x 1 3/4”) 4 19 Hex Head Bolt (1/4-20 x 1/2”) 3 20 Tank 1 21 Hose Assembly 1 8001-010 22 Reducer (.500) 1 23 Tee Fitting (1/8” F - 1/8” F - 1/8” M) 1 V722147 thru V1542471 24 Adapter (1/8” M - 1/8” M) 2 25 Poly-Flow Tube (sold by the inch) 27 4 910572400 15 14 1062949407 13 12 20224304 Models: Serial Numbers: 11 8001-009 V700471 thru V1166946 © Midmark Corporation 2008 SF-1930 [Revised: 7/8/14] Qty. Quick Connect Fittting (1/4”) 16 041-0250-17 Description 1 17 002-1149-00 Tank, Fan, Fittings and Tubing E-35 Always verify model & serial number 1 Back Next Go to Table of Contents 77000092 20224305 24 62900918 10589900 20214200 162982202 25 265967000 24 23 310589600 420224306 22 21 520224302 20 30193601 620224303 19 040-0250-133 62500176 710589600 18 10597500 20231200 Item 877005020 17 4 16 002-1149-00 041-0250-17 910572400 15 14 1062949407 13 12 20224304 11 Description Qty. 1 Quick Connect Fittting (1/4”) 1 2 Check Valve 1 3 Street Tee (1/4” NPT) 1 4 Adapter (1/4” MNPT - 1/4” FNPT) 2 5 Hose Tank to Switch 1 6 Hose Compressor to Tank 1 7 Street Tee (1/4 NPT) 1 8 Pressure Relief Valve 1 9 Fan 1 10 Nut, Pem (6-32) 4 11 Drain Hose 12 Refer to: Electrical Box Assembly Ref 13 Refer to: Air Regulator System Assembly Ref 14 Nut 1 15 Intake Filter ( Replacement Filter Only) 1 16 Solenoid (includes fitting and filter) (*Filter only order PN - 002-1143-00) 1 17 Timer, Delay 1 18 Pan Head Screw (6-32 x 1 3/4”) 4 19 Hex Head Bolt (1/4-20 x 1/2”) 3 20 Tank 1 21 Hose Assembly 1 Reducer (.500) 1 1 1 8001-009 8001-010 22 23 Tee Fitting (1/8” F - 1/8” F - 1/8” M) V1166947 thru Present V1542472 thru Present 24 Adapter (1/8” M - 1/8” M) 2 25 Poly-Flow Tube (sold by the inch) 27 Models: Serial Numbers: Tank, Fan, Fittings and Tubing © Midmark Corporation 2008 SF-1930 [Revised: dd/mo/yr] E-35.1 Always verify model & serial number Back Next Go to Table of Contents 110597100 Test 230193501 20227806 10597100 5 4 340157703 VA1475 Compressor Item Models: Serial Numbers: 8001-009 V700471 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 8/2/13] 8001-010 V722147 thru Present E-36 Description Qty. 1 Capacitor 1 2 Replacement Head (with capacitor) 1 3 Base Plate 1 4 Guard 1 5 Cap Screw (6-32) 2 Always verify model & serial number Back Next Go to Table of Contents 1ECC10108 262900700 77005143 18 310590100 420213202 520227803 77001094 17 6109714 16 109714 62906101 6 7117660 8117352 15 1 Elbow Street, (18” NPT) 2 3 Reducer (3/8” NPT - 1/8” NPT) 1 4 Regulator Bracket 1 5 Cap Screw (10-32) 2 6 Barb Fitting (#10-32 x 1/16’) 3 7 Gasket (.188 x .312 x .031) 2 8 Fitting (1/8” NPT x # 10-32) 1 9 Brown Hose (1/8” x 4” length) 1 10 Water Regulator 1 11 Cable Tie 1 12 Barb Fitting (# 10-32 x 3/16”) 1 13 Air Regulator 1 14 Master Shut-Off Valve 1 8001-010 15 Elbow, 90 Degree, Female x Female (1/8” NPT) 1 16 Fitting 1 V722147 thru Present 17 Locknut, Conduit (1/2”) 1 18 Pressure Switch 1 13 10014-0633-00 12 61955601 Models: Serial Numbers: 8001-009 V700471 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 3/6/14] Qty. 2 9177551 10591900 Description Connector Conduit, Straight 14 10589200 Item 1 7 20230900 Air Regulator System 11 VA1478 6 E-37 Always verify model & serial number Back Next Go to Table of Contents 110573600 2 210572300 4 13 3015-2991-00 20227802 462885208 11 20227806 10572100 10573500 12 10 9 V700471 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 6/20/12] Qty. 1 2 Outlet, NEMA 2 3 Thermostat 1 4 Strain Relief 2 5 GFIC Outlet 1 6 Door, Electrical 1 7 Warning Label 1 8 On/Off Switch 1 9 Power Cord 1 8001-010 10 Inlet 1 11 Cap Screw (#6-32) 2 V722147 thru Present 12 Cap Screw (#10-32) 13 Refer to: Frame & Enclosure 810572200 8001-009 Description Power Supply for Scaler 720230300 Models: Item 1 620213401 Serial Numbers: Electrical Box 510572000 E-38 VA1479 Always verify model & serial number 1 Ref Back Next Go to Table of Contents 1053-1218-01 030-1798-00-216 2016-0856-02 5 122348 040-0010-126 7 3016-0837-00 6 2 4040-0250-07 Unit Arm Assembly - Table Mount VA1490 Models: 8001-003 Serial Numbers: © Midmark Corporation 2008 SF-1930 Item Description Qty. 1 Joint Cover 1 2 Needle Bearing 2 3 Slotted Bearing 1 4 Bolt (1/4-20 x 1/2”) 2 8001-007 5 Unit Arm Weldment 1 6 Set Screw (.190-32 x 1/4”) 1 all 7 Dowel Pin 1 all [Revised: 10/16/12] Also Refer to: Water System - Table Mount E-39 Always verify model & serial number Back Next Go to Table of Contents 16 016-0856-00 1030-1801-00-216 2040-0250-155 3120385 4050-7788-00-xxx 5002-1709-00 15 040-0250-13 016-0149-20 14 7120233-50 13 117481 053-1463-00 6053-1992-00-216 12 014-0176-52 Water System - Table Mount 11 Item 10 117482 177524 9 053-1828-00 Models: 8001-003 8001-007 all all Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 8/29/13] 8 VA149101i E-40 Description Qty. 1 Bearing Mount Assembly 1 2 Set Screw 1 3 Pan Head Screw (#8-32” x 1/2“) 2 4 Water Bottle Bracket 1 5 Toggle Switch Assembly 1 6 Bearing Mount Cover 1 7 Screw, Panel with Washer (#10-32 x .38) 6 8 Water Bottle (1 liter) 1 9 Tubing (1/4” OD x .159 ID) 1 10 Barbed Union Fitting (1/8” to 1/8”) 1 11 O-ring 1 12 Cap 1 13 Barbed Fitting (1/16” to 1/6”) 2 14 Glide Bearing 1 15 Pan Head Screw (1/4”-20 x 5/8”) 4 16 Needle Bearling 1 17 Table Mount Loose Parts Kit (002-1419-00 {includes item 7 and miscellaneous screws]) 1 Always verify model & serial number Back Next Go to Table of Contents 1053-2083-00-216 16 040-0010-109 2054-0581-00 3054-0583-00 054-0582-00 15 4050-7743-00-341 16 5 050-7742-00 14 6 7 137258 8016-1243-00 13 9 029-4884-00 12 1162400706 Models: Serial Numbers: 1077007026 VetPro® Solo 8006-001 0905SOL0001 thru 0910SOL0015 V759502 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 4/28/15] E-41 Sound Cover & Water Connection Assemblies Item Description Qty. 1 Cover, Power Unit 1 2 Foam, Sound Dampening W/ Adhesive Back 1 3 Foam, Sound Dampening W/ Adhesive Back 2 4 Umilical Clamp 5 Refer to: Tubing and Fittings Ref 6 Refer to: Tubing and Fittings Ref 7 Refer to: Tubing and Fittings Ref 8 Water Check Valve 9 Refer to: Tubing and Fittings 10 Mount, Sandwich 4 11 Nut, Lock (1/4-20) 4 12 Water Supply, Power Unit 1 13 Coupling, FEM OD 2 14 Base Power Unit 1 15 Foam, Sound Dampening w/Adhesive Back 2 16 Screw, (10-24 x 3/8”) 10 Always verify model & serial number 2 2 Ref Back Next Go to Table of Contents Athena Handpiece Replacement Parts 1016-1267-01 2016-1267-00 3016-1267-02 4016-1267-06 5 a) 016-1267-03 b) 016-1267-04 6016-1267-05 Athena Handpiece Replacement Parts Item Description Qty. 1 4-Hole Gasket 1 2 5-Hole Gasket 1 3 2-Hole Gasket for Little Pro 1 4 Standard & mini head push button cap wrench 5 Push Button Canister: a) Standard Head without Cap (Fiber Optics only) b) Mini Head without Cap (Non-Fiber Optics only) 6 Standard & mini head push button head cap 7 • 002-1238-00 - Scaler Tips, Ultrasonic, Vet (Includes items 8 thru 10) 8 •• 016-1203-05 - Ultrasonic Stones, Dog Probe Short 1 9 •• 016-1203-06 - Ultrasonic Stones, Cat Probe 1 10 •• 016-1203-07 - Ultrasonic Stones, Dog Probe Long 1 1 Items # 7 thru # 11 are not shown Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 All all [Revised: 01/20/11] E-42 Always verify model & serial number 1 kit Back Next Go to Table of Contents 77005020 PCB50647 62900510 65967000 10589600 24 19 23 016-1248-00 016-1246-01 22 2762900712 26 25 110589100 2016-1247-00 28016-1219-00 5016-1244-00 20 Compressor and Air Tank Components 20224306 19 27 18 62900511 17 029-4895-00 16 PVV50525 10572900 27 6040-0250-133 65970501 15 7 14 13 65971300 11 12 041-0250-17 VA1568 10 62400706 Models: Serial Numbers: Test 430193501 21 016-1245-00 310597100 877007026 9 VetPro® Solo 8006-001 0905SOL0001 thru 0910SOL0015 V759502 thru V784999 © Midmark Corporation 2008 SF-1930 [Revised: 5/8/14] E-43 Item Description Qty. 1 Intake Filter 2 2 Hose Assy, PVC, (1/4 MNPT-1/4 FNPT, 1/4” ID) 1 3 Capacitor 1 4 Replacement Head (with capacitor) 1 5 Vibration Isolation Mount 4 6 Hex HD Whiz LK, (1/4-20 X 1/2”) 1 7 Refer to: Sound Cover and Water Connection Assemblies 8 Rubber Foot 4 9 Lock Nut 4 10 HN FL , (1/4-20) Ref 11 Refer to: Air Regulator Components 12 Elbow 1 13 Panel Mount 1 14 Petcock 1 15 Hose Assemby 1 16 Solenoid (includes fitting and filter) (*Filter only order PN - 002-1143-00) 1 17 Adaptor (1/8” x 1/4”) 1 18 Hose Assy, SS, (1/4 MNPT ENDS, 1/4” ID) 1 19 Adapter, (1/4” MNPT x 1/4” FNPT) 2 20 Street Tee, (1/4” NPT) 1 21 Check Valve (1/4” NPT) 1 22 Nipple, Hex, (1/4” x 1/4” SEAL) 1 23 Tee Run, (1/4”) 1 24 Valve,Air Safety, (125 PSI) 1 25 Hose Assy, PVC, (1/4 MNPT ENDS, 1/4” ID) 1 26 Hose Assy, PVC, (1/4 MNPT-1/8 MNPT, 1/4” ID) 1 27 Elbow Street, (1/4” NPT W/SEAL) 3 28 Pressure Tank, One GAL 1 Always verify model & serial number Ref Back Next Go to Table of Contents 77005020 20224306 016-1246-01 29 22 28 3062900712 2014-0317-02 Test 310597100 110589100 25 430193501 24 65967000 10589600 016-1248-00 6 PCB50647 62900510 27 Compressor and Air Tank Components 23 22 30 016-1245-00 21 20 62900511 029-4895-00 10572900 8040-0250-133 30 19 65970501 PVV50525 31 016-1219-00 9 040-0250-79 18 17 7 016-1195-00 041-0006-02 16 65971300 © Midmark Corporation 2008 SF-1930 10040-0006-108 13 62400706 Serial Serial Numbers: Numbers: 5 14 15 041-0250-17 Models: 6 12 1177007026 8006-001 V785000 thru V1556602 [Revised: 7/8/14] E-43.1 Item Description Qty. 1 Intake Filter 1 2 Adapter 1 3 Capacitor 1 4 Replacement Head (with capacitor) 1 5 Keps Nut w/lockwasher (#6-32) 8 6 Bubble Mount 4 7 Screw (1/4-20 X 5/8”) 4 8 Hex HD Whiz LK, (1/4-20 X 1/2”) 9 Refer to: Sound Cover and Water Connection Assemblies 10 Screw (#6-32 X 3/8”) 8 11 Rubber Foot 4 12 Lock Nut 4 13 HN FL , (1/4-20) 4 Ref 14 Refer to: Air Regulator Components 15 Elbow (1/4”) 16 Panel Mount 1 17 Petcock 1 18 Hose Assembly 1 19 Solenoid (includes fitting and filter) (*Filter only order PN - 002-1143-00) 1 20 Adaptor (1/8” x 1/4”) 1 21 Hose Assy, SS, (1/4 MNPT ENDS, 1/4” ID) 1 22 Adapter, (1/4” MNPT x 1/4” FNPT) 2 23 Street Tee, (1/4” NPT) 1 24 Check Valve (1/4” NPT) 1 25 Nipple, Hex, (1/4” x 1/4” SEAL) 1 26 Tee Run, (1/4”) 1 27 Valve,Air Safety, (125 PSI) 1 28 Hose Assy, PVC, (1/4 MNPT ENDS, 1/4” ID) 1 29 Hose Assy, PVC, (1/4 MNPT-1/8 MNPT, 1/4” ID) 1 30 Street Elbow (1/4” NPT W/SEAL) 6 31 Pressure Tank, One GAL 1 Always verify model & serial number Ref Back Next Go to Table of Contents 77005020 6 PCB50647 62900510 20224306 016-1248-00 016-1246-01 29 22 28 3062900712 2014-0317-02 Test 310597100 110589100 25 430193501 24 65967000 10589600 27 Compressor and Air Tank Components 23 22 30 016-1245-00 21 20 62900511 029-4895-00 10572900 8040-0250-133 30 19 65970501 PVV50525 31 016-1219-00 9 040-0250-79 18 17 7 016-1195-00 041-0006-02 16 65971300 © Midmark Corporation 2008 SF-1930 10040-0006-108 13 62400706 Serial Numbers: 5 14 15 041-0250-17 Models: 6 12 1177007026 8006-001 V1556603 thru Present [Revised: dd/mo/yr] E-43.2 Item Description Qty. 1 Intake Filter 1 2 Adapter 1 3 Capacitor 1 4 Replacement Head (with capacitor) 1 5 Keps Nut w/lockwasher (#6-32) 8 6 Bubble Mount 4 7 Screw (1/4-20 X 5/8”) 4 8 Hex HD Whiz LK, (1/4-20 X 1/2”) 9 Refer to: Sound Cover and Water Connection Assemblies 10 Screw (#6-32 X 3/8”) 8 11 Rubber Foot 4 12 Lock Nut 4 13 HN FL , (1/4-20) 4 Ref 14 Refer to: Air Regulator Components 15 Elbow (1/4”) 16 Panel Mount 1 17 Petcock 1 18 Hose Assembly 1 19 Solenoid (includes fitting and filter) (*Filter only order PN - 002-1143-00) 1 20 Adaptor (1/8” x 1/4”) 1 21 Hose Assy, SS, (1/4 MNPT ENDS, 1/4” ID) 1 22 Adapter, (1/4” MNPT x 1/4” FNPT) 2 23 Street Tee, (1/4” NPT) 1 24 Check Valve (1/4” NPT) 1 25 Nipple, Hex, (1/4” x 1/4” SEAL) 1 26 Tee Run, (1/4”) 1 27 Valve,Air Safety, (125 PSI) 1 28 Hose Assy, PVC, (1/4 MNPT ENDS, 1/4” ID) 1 29 Hose Assy, PVC, (1/4 MNPT-1/8 MNPT, 1/4” ID) 1 30 Street Elbow (1/4” NPT W/SEAL) 6 31 Pressure Tank, One GAL 1 Always verify model & serial number Ref Back Next Go to Table of Contents 10572400 21 120232300 220224306 362900712 11 7 20 10597500 477001090 577005143 677001095 11 050-7739-00-216 015-3386-00 19 Note Older units have a thermostat without mounting bracket. The new kit (item # 8) has a bracket so the new thermostat fits on older units. 7040-0006-99 9 18 8015-2991-00 040-0006-99 17 977001094 16 62970703 10050-7740-00-216 15 BNT20210 10572200 11040-0010-109 14 1262885204 10572000 13 VA1570 Models: Serial Numbers: VetPro® Solo 8006-001 0905SOL0001 thru 0910SOL0015 V759502 thru Present © Midmark Corporation 2008 SF-1930 [Revised: 7/3/14] E-44 Electrical Components Item Description Qty. 1 Power Supply 1 2 Adapter 1 3 Elbow Street, (1/4” NPT W/SEAL) 1 4 Hole Plug 1 5 Pressure Switch 1 6 Nipple,Conduit, (1/2” X 1” LG) 1 7 Screw, (6-32 X 1/2) 4 8 Thermostat Replacement Kit (includes item # 7 and Bracket) 4 9 Locknut, Conduit (1/2”) 2 10 Pressure Switch Bracket 1 11 Screw, (10-24 X 3/8”) 9 12 Strain Relief 1 13 GFIC Receptical 1 14 Circuit Breaker Switch 1 15 Nut, Lock, Keps, (10-32) 3 16 Terminal Strip 17 Screw, (6-32 x 1/2”) 2 18 Snap-In Receptacle 2 19 Electrical Enclosure, Power Unit 1 20 Timer 1 21 Fan 1 22 Not Shown 77001176 - Jumper on Terminal Strip 3 Always verify model & serial number Back Next Go to Table of Contents 014-0659-00 2 15 3 050-7741-00-216 3 13 20230900 62906101 14 1122743 12 3 2002-1660-00 3 3 4016-1242-00 3 3 3 040-0010-109 Air Regulator System 11 Item 77002047 10 5014-0542-01 10589200 9 8 117352 10591900 Models: Serial Numbers: VA1569 7 6 VetPro® Solo 8006-001 0905SOL0001 thru 0910SOL0015 V759502 thru V784999 © Midmark Corporation 2008 SF-1930 [Revised: 7/21/16] S059-00155 E-45 Description Qty. 1 3-Way Tee 2 Water Regulator Kit (includes uniclamps) 3 Refer to: Tubing and Fittings 4 Pilot Valve 1 5 Barb Fitting, (3/16” to 3/16”) 1 6 Tubing, (.312 OD x .188 ID) 1 7 Male Thread to Tube (10-32) 1 8 Fitting 1 9 Regulator, Shut-off Assembly 1 10 Closed Nipple 1 11 Screw, (10-24 X 3/8”) 2 12 Elbow,90 (FEM X FEM 1/8NPT) 1 13 Master Pilot Shut-off 14 Regulator Bracket 1 15 Mounting Nut - Regulator 1 Always verify model & serial number 1 2 Ref Back Next Go to Table of Contents 1 002-1660-00 2 16 20230900 3 2 014-0659-00 4 050-7741-00-216 5122743 62906101 2 15 2 2 7 S059-00155 6016-1242-00 8014-0542-01 2 2 9016-0888-00 040-0010-109 Air Regulator System 14 77002047 Item 13 10589200 2 12 117352 11 10591900 1 10 VA156901i Models: Serial Serial Numbers: Numbers: © Midmark Corporation 2008 SF-1930 8006-001 V785000 thru Present [Revised: 7/21/16] E-45.1 Description Qty. 1 Water Regulator Kit (includes uniclamps) 2 Refer to: Tubing and Fittings 3 Mounting Nut - Regulator 1 4 Regulator Bracket 1 5 3-Way Tee 1 6 Pilot Valve 1 7 Tubing (.312 OD x .188 ID) 1 8 Barb Fitting (3/16” to 3/16”) 1 9 90° Swivel Fitting (#10-32) 1 10 Fitting (#10-32 X 3/16” Barb) 1 11 Fitting 1 12 Air Regulator Assembly 1 13 Closed Nipple 1 14 Screw (#10-24 X 3/8”) 2 15 90° Elbow (FEM X FEM 1/8 NPT) 1 16 Master Shut-Off Valve Always verify model & serial number 2 Ref Back Next Go to Table of Contents 016-1550-00 1 2016-1546-00 3016-1547-00 4016-1548-00 5016-1549-00 Scaler Components Item Models: Serial Numbers: © Midmark Corporation 2008 SF-1930 8001-001, -002, -003, -009 V753921 thru V1321184 [Revised: 6/7/12] 8001-005, -006, -007, -010 V753921 thru V1321184 46 Description Qty. 1 O-Ring Kit 1 2 Nose 1 3 O-Ring (9.9 X 0.75) 1 4 Body 1 5 O-Ring (12.5 X 1.5) 1 Always verify model & serial number Back Next Go to Table of Contents 2016-1553-00 016-1550-00 1 3016-1554-00 4016-1376-00 5016-1552-00 5016-1551-00 LED Scaler Components Item Models: Description Qty. 1 O-Ring Kit 1 2 O-Ring (12.5 X 1.5) 1 8001-005, 8001-006, 8001-007, 8001-010 3 O-Ring (16 x 1) 1 4 LED Light Ring 1 V1321185 thru Present 5 LED Focus Light Guide 1 6 Nose 1 Serial Numbers: © Midmark Corporation 2008 SF-1930 [Revised: 6/7/12] E-46.1 Always verify model & serial number Back Go to Table of Contents SUBJECT TO CHANGE WITHOUT NOTICE Midmark Corporation For contact information, go to: www.midmark.com