data sheet - TransTech

advertisement
From
Mains Power Supply to Low Volts & Communications
www.transtech.com.au
TRANSTECH ELECTRONIC CONTROLS
Electronic Transient Surge Protection
Transtech Electronic Controls Pty Ltd
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: (03) 9330-3624
Info@transtech.com.au
Also in Melbourne - Sydney – Brisbane – Adelaide
TRANSTECH
TLP Transient Lightning Protection
This is a TLP overview - contact sales for the full range of TLP protectors
Process - Industrial - Mining - Commercial - Government - Factories - Research
MAINS PROTECTORS
CAT C, 20kV AND 20 kA - use TLP-80-3P, TLP-120-3P, TLP-160-3P
CAT B, 6kV and 3kA - use TLP-8-1P/240 OR TLP-150-3P/CATB,
AS 1768
IEEE C62 compliant
VOLTAGE Nominal
(Vrms)
Maximum (Vrms)
MODELS
FIG 1
FIG 2
FIG 3
FIG 4
FIG 5
PEAK DISCHARGE
CURRENT
Per Mode 8/20usec
(kA)
MAX “LET-THRU”
VOLTAGE
Volts/Modes
INDICATION
Visual/Remote
FIGURE No
DIMENSIONS
in mm
390 / 2
600 / 2
<600 / 3
<600 / 3
<600 / 3
<810 / 3
<810 / 3
<810 / 3
<810 / 3
<810 / 3
<810 / 3
<810 / 3
<710 / 3
<810 / 1
N/N
N/N
Y/Y
Y/Y
Y/Y
Y / Y + FIG9
Y / Y + FIG9
Y / Y + FIG9
Y / Y + NEM
Y / Y + NEM
Y / Y + NEM
Y / Y + NEM
Y/Y
Y/N
Ref HO
Ref HO
FIG 1
FIG 1
FIG 1
FIG 1
FIG 1
FIG 1
FIG 3
FIG 3
FIG 3
FIG 3
FIG 4
FIG 4
FIG 9
FIG 10
FIGURE No
DIMENSIONS
in mm
W
H
D
12.5
75
53
12.5
75
53
80
110
85
80
110
85
80
110
85
105
120
75
kA
Low Cost DIN 1 PH (Cat A)
TLP-8-1P/120V
TLP-8-1P/240V
High Spec DIN 1 PH (Cat C)
TLP-40-1P
TLP-80-1P
TLP-120-1P
High Spec DIN 3 PH (Cat C)
TLP-P40-3DRI
Compact series DIN profile
TLP-P80-3DRI
Remote status/Indication capable
TLP-P120-3DRI
High E-N Fault DIN 3 PH (Cat C)
TLP-80-3P/NEM
With unique N to E monitoring feature = NEM TLP-120-3P/NEM
TLP-160-3P/NEM
TLP-200-3P/NEM
Compact Series DIN PROFILE (Cat A or B) TLP-150-3P/CAT B
No neutral required for this model
TLP-415P-E-DIN
120 /
240 /
240 /
240 /
240 /
240 /
240 /
240 /
415 /
415 /
415 /
415 /
415 /
415 /
150
275
275
275
275
275
275
275
475
475
475
475
475
475
8.5
8.5
40
80
120
40
80
120
80
120
160
200
40
40
105
120
75
105
120
75
150
110
85
150
110
85
150
110
85
150
110
85
150
110
85
43
110
85
SERIES FILTERS UP TO 40 AMPS
CAT B & A, 6kV @ 20 Amps.
AS 1768, IEEE C62 compliant
VOLTAGE Nominal
(Vrms)/
Maximum (Vrms)
MODELS
FIG 6
FIG 7
FIG 8
PEAK DISCHARGE
CURRENT
With 8/20usec (kA)
MAX “LET-THRU”
VOLTAGE
Volts/Modes
INDICATION
Visual/Remote
W
kA
Industrial (Cat B)
Integral 20Amp series filter
Integral 20Amp series filter
Integral 20Amp series filter + Relay
Integral 20Amp series filter + Relay
Integral 40Amp series filter
Integral 40Amp series filter
Series OR Parallel Cat B
Up to 20 amps series connected
unlimited in parallell connected
TLP-GPO-10A
TLP-SF20SL-120V (DIN style)
TLP-SF20SL-240V (DIN style)
TLP-SF20RI-120
TLP-SF20RI-240
TLP-SF40T-P120
TLP-SF40T-P240
TLP-SP20SL 30V
TLP-SP20SL 50V
TLP-SP20SL 150V
TLP-SP20SL 275V
240/275
120 / 275
240 / 275
240 / 275
240 / 275
185 / 210
255/275
30 / 40
50 / 60
150 / 170
240 / 275
20
48
48
48
48
48
48
54
72
72
72
710 /
385 /
600 /
600 /
600 /
810 /
810 /
600 /
690 /
690 /
690 /
2
3
3
3
3
3
3
3
3
3
3
H
N/N
Y/N
Y/N
Y/Y
Y/Y
Y/N
Y/N
Y/ N
Y/N
Y/N
Y/ N
FIG 6
FIG 6
FIG 8
FIG 8
FIG 10
FIG 10
FIG 7
FIG 7
FIG 7
FIG 7
FIG 14
FIG 15
FIGURE No
DIMENSIONS
in mm
D
1 x 10A GPO ith 2mtr lead
23
115
85
23
115
85
23
115
85
23
115
85
95
115
85
95
115
85
23
115
85
23
115
85
23
115
85
23
115
85
LOW VOLTAGE PROTECTORS, INSTRUMENTATION
AND COMMUNICATIONS (Cat A & B)
AS 1768, IEEE C62 compliant
VOLTAGE Nominal
(Vrms)
Maximum (Vrms)
MODELS
FIG 11
FIG 12
FIG 13
PEAK DISCHARGE
CURRENT
With 8/20usec (kA)
MAX “LET-THRU”
VOLTAGE
Volts/Modes
INDICATION
Visual/Remote
W
H
D
17.5
75
65.5
6.2
90
100
6.2
90
100
6.2
90
100
6.2
90
kA
Signals (either Analog or Digital)
transmitters or switches
* Other voltages
upon request
Protects 24v loop M20 entry
Protects 24v loop NPT entry
Protects 24v supply as well as loop M20 entry
Protects 230v supply as well as loop M20 entry
Bus Protectors
* Other types upon request
Coaxial RF Protectors
* Other types upon request
TLP-15L TO TLP-60L
TLP-SL62-xxD (2 ch 6.2mm wide)
TLP-SL62-xxD (2 ch 6.2mm wide)
TLP-SL62-xxD (2 ch 6.2mm wide)
TLP-SL62-xxD (2 ch 6.2mm wide)
TLP-48HM/M20
TLP-48HM/NPT
TLP-48HM-4W/M24
TLP-48HM-4W/M240
TLP-RS232
TLP-RS485
TLP-RS485/MB
TLP-RS485/PB
TLP-DNET
TLP-48/RJ45H-4
TLP-N/FF
TLP-F/MF
TLP-F/FF
15 /
15 /
16 /
17 /
18 /
18 - 60 / 70
18 - 60 / 70
18 - 60 / 70
18 - 60 / 70
18 - 60 / 70
24 / 48
24 / 48
24 / 48
240/24/48
±15 / ±18
±12 / ±15 Vdc
±12 / ±15 Vdc
±12 / ±15 Vdc
24 / 31
24 / 31
70V
90V
90V
8
8
8
8
8
10
10
10
10
400W PPPD
400W PPPD
400W PPPD
400W PPPD
400W PPPD
400W PPPD
20
20
20
18 / 3
21 / 3
43 / 3
75 / 3
90 / 3
28 / 3
28 / 3
28 / 3
28 / 3
19 / 2
19 / 2
19 / 2
19 / 2
19 / 2
19 / 2
700 / 1kV/Ms
700 / 1Kv/Ms
701 / 1Kv/Ms
Notes and Standards: AS 1768-2005, IEC61643-1, BS 6651-1992, IEEE C62. 41-1991, BS 2914-1972
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N/
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Compliance:
Perth - Melbourne - Sydney - Brisbane - Adelaide
TransTech Electronic Controls Pty Ltd
Perth H.O Design/Manufacturing
Contact: Dale Tunbridge
or
John King
MOB:
or
0419-502-660 or
or
john@transtech.com.au
0439 911-883
or
Mark Van Schalm (Melbourne)
0409 697-156
Unit 2 / 48 Dellamarta Road
WANGARA W.A. 6065
dale@transtech.com.au
\\server\i\Shared\Price Lists & data sheets\Transtech\Flyers\TLP_Listing.xlsx
or
mark@transtech.com.au
FIG 14
FIG 13
FIG 13
FIG 13
FIG 13
FIG 15
FIG 15
FIG 15
FIG 15
FIG 14
FIG 14
FIG 14
.FIG 14
FIG 14
FIG 12
FIG 11
FIG 11
FIG 11
N2909
100
-
172
25 hex
-
172
25 hex
-
172
25 hex
-
172
25 hex
17.5
75
65.5
17.5
75
65.5
17.5
75
17.5
75
65.5
30
75
65.5
85
55
25
65.5
TNC FEM/FEM Bulkhead
F FEM/MALE
F FEM/FEM
Transient Protection Presentation
5. Transient Standards Categories and Definitions.
According to AS 1768:2005 the installation of transient over-voltage protectors can
be broken down into five (5) categories.
Such categories are shown below from highest risk (E) to lowest risk (A):
CAT E
6kV / 70kA
The Point of entry to “very exposed or
critically important site.
Example: Telecom tower on hill.
CAT D
6kV / 30kA
CAT E – very high risk
The point of entry to an exposed rural
site.
Example: Pump station a Country Area
CAT C
6kV / 15 - 20kA
The point of entry to a site in the City or
built up area.
Example: Most common building or site
CAT B
6kV / 3kA
Within a building immediately after the
point of entry or Main Board.
Example: Sub-boards.
C
CAT A
B
B
6kV / 500Amp
Within a building and fed from a sub-board
being CAT B location.
Example: GPO,s
C
B
A
A
- 10 –
I:\Shared\Price Lists & data sheets\Transtech\Application Notes\TLP Presentation_new.docx
TRANSTECH
DATA SHEET
Subject to change without notice
MODEL :- TLP-80-1P
Transtech Lightning Protector - 240V Single Phase, 3 Modes
For CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
220VAC rms
275VAC rms
40 - 60Hz
less than 800V
Imax
Response time
Relay Contacts
Surge Reset
80kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
80(W) x 80(H) x 115(L)
Relay Output
Phase loss or Neutral
Disconnected the relay
de-energizes.
Power On / Unit Healthy,
(LED ON = healthy)
LED’s (2)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
GENERAL DESCRIPTION
The TLP-80-1P is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP-80-1P is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3
modes.
2
Plug in 2.5mm
Red LED’s
Mild Steel(Powder coated)
80 (H) x 80 (H) x 115 (L)
850 grams
DIN 43880 Standard DIN Rail
The TLP-80-1P offers a DIN style housing to suit most MCB
profiles.
For mains supply of greater than 100A adequate HRC fuse
or MCB protection must be installed prior to the TLP-xx 1P.
FEATURES
REMOTE RELAY OUT
Model No
TLP-80-1P
TRANSTECH
UNIT
HEALTHY
3
2
1
Remote Alarm
1 = N/O | 2 = COMM | 3 = N/C
POWER
ON
SINGLE PHASE
TRANSIENT PROTECTOR
(Replace if OFF)
L1
CAT C
V = 240V
In = 40kA
Imax = 120kA
N E
SUPPLY
L1
LOAD
N
E
CONNECTION
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Neutral to Earth Monitor
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2003
NOTE: This device must be installed by a
Qualified Electrician
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-80-1P new.docx
05/02/2011
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-120-1P
Transtech Lightning Protector - 240V Single Phase, 3 Modes
For CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
220VAC rms
275VAC rms
40 - 60Hz
less than 800V
Imax
Response time
Relay Contacts
Surge Reset
120kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or Neutral
Disconnected the relay
de-energizes.
Power On / Unit Healthy,
(LED ON = healthy)
LED’s (2)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
80(W) x 80(H) x 115(L)
GENERAL DESCRIPTION
The TLP-120-1P is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP-120-1P is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3
modes.
2
Plug in 2.5mm
Red LED’s
Mild Steel(Powder coated)
80 (H) x 80 (H) x 115 (L)
850 grams
DIN 43880 Standard DIN Rail
The TLP-120-1P offers a DIN style housing to suit most
MCB profiles.
For mains supply of greater than 100A adequate HRC fuse
or MCB protection must be installed prior to the TLP 1P.
FEATURES
REMOTE RELAY OUT
Model No
TRANSTECH
TLP-120-1P
UNIT
HEALTHY
3
2
1
Remote Alarm
1 = N/O | 2 = COMM | 3 = N/C
POWER
ON
SINGLE PHASE
TRANSIENT PROTECTOR
(Replace if OFF)
L1
CAT C
V = 240V
In = 40kA
Imax = 120kA
N E
SUPPLY
L1
LOAD
N
E
CONNECTION
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Neutral to Earth Monitor
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed motherboard
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2003
NOTE: This device must be installed by a
Qualified Electrician
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-120-1P new.docx
05/02/2011
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-P80-3DRI
Transtech Lightning Protector - 415V Three Phase, 3 Mode
For CAT C
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
Less than 810V
In
Imax
Response time
Relay Contacts
Surge Reset
36kA
80kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss disconnected
the relay de-energizes.
L1, L2, L3,
(LED ON = healthy)
(LED AMBR = replace)
LED’s (dual colour)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
GENERAL DESCRIPTION
The TLP-P80-3DRI is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP-P80-3DRI is a true 3 mode (L-L / L-N / N-E) parallel
connected surge protection device offering protection for all 3
phases, it also introduces a unique feature, by being connected to
a TLP-DSI which will indicate the status of each phase remotely.
2
Plug in 2.5mm
Red / Amber LED’s
Mild Steel(Powder coated)
105 (W) x 120 (H) x 75 (D)
700 grams
DIN 43880 Standard DIN Rail
RELAY
OUT
LE D’s L1 -L2-L3
RED = OK
AMBE R = DECRE ASE D
OFF = REP LACE TLP
TLP-P80-3DRI
3PH + E
SURGE PROTECTION
L1
L1
L1
N E
LOAD SIDE
SUPPLY SIDE
FUSE/MCB PROTECT ION
L1
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xx-3P.
FEATURES
REMOTE IND
OUT
TRANSTECH
The TLP-P80-3DRI is powered by all 3 phases and does not lose
indication until all 3 phases have failed. This is a distinct
advantage over units where indicators are powered from a single
phase.
L1
L2
L2
L3
L3
N
N
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Internally protected – automatic reset
Local status indication by dual colour LED’s
Remote panel indicator
Alarm status indication via in-built c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and AS/NZS
1768:2003
E
E
CONNECTION DIAGRAM
NOTE: This device must be installed by a Qualified
Electrician
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-P80-3DRI new.docx
30 Jan 2010
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-80-3P/NEM
Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral to Earth Monitoring
For CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
Less than 810V
Imax
Response time
Relay Contacts
Surge Reset
80kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or Neutral &
Earth both disconnected
the relay de-energizes.
L1, L2, L3, N-E
(LED ON = healthy)
LED’s (4)
GENERAL DESCRIPTION
The TLP-80-3P/NEM is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
155(W) x 105(D) x 85(H)
The TLP-80-3P/NEM is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3 modes.
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
2
Plug in 2.5mm
Red LED’s
Mild Steel(Powder coated)
155 (W ) x 105(D) x 85 (H)
850 grams
DIN 43880 Standard DIN Rail
The TLP-80-3P/NEM now offers a Neutral to Earth protection
monitoring circuit (NEMON) which until now has not been
available. The NEMON circuit ensures that all 3 modes of
protection are active and offers a fully monitored and reliable
protection device.
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xx-3P/NEM.
REMOTE RELAY OUT
RELAY OUT
1 = N/O
2 = COMM
3 = N/C
FEATURES
1 2 3
TLP-80-3P/NEM
THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR
L1
L2
L3
NE
SUPPLY
L1
L2
L3
N
E
LOAD
CONNECTION
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Neutral to Earth Monitor
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and AS/NZS
1768:2003
NOTE: This device must be installed by a Qualified
Electrician
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-80-3P_NEM new.docx
30 Jan 2010
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-P130-3DRI
Transtech Lightning Protector - 415V Three Phase, 3 Mode
For CAT C
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
Less than 810V
In
Imax
Response time
Relay Contacts
Surge Reset
43kA (10 Impulses)
130kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss disconnected
the relay de-energizes.
L1, L2, L3,
(LED RED = healthy)
(LED AMBER = replace)
LED’s (dual colour)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
GENERAL DESCRIPTION
The TLP-P130-3DRI is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP-P130-3DRI is a true 3 mode (L-L / L-N / N-E) parallel
connected surge protection device offering protection for all 3
phases, it also introduces a unique feature, by being connected to
a TLP-DSI which will indicate the status of each phase remotely.
2
Plug in 2.5mm
Red / Amber LED’s
Mild Steel(Powder coated)
105 (W) x 120 (H) x 75 (D)
700 grams
DIN 43880 Standard DIN Rail
REMOTE IND
OUT
LE D’s L1 -L2-L3
RED = OK
AMBE R = DECRE ASE D
OFF = REP LACE TLP
TLP-P130-3DRI
3PH + E
SURGE PROTECTION
L1
L1
L1
N E
LOAD SIDE
SUPPLY SIDE
FUSE/MCB PROTECT ION
L1
L1
L2
L2
L3
L3
N
N
E
E
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xx-3P.
FEATURES
RELAY
OUT
TRANSTECH
The TLP-P130-3DRI is powered by all 3 phases and does not
lose indication until all 3 phases have failed. This is a distinct
advantage over units where indicators are powered from a single
phase.
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Internally protected – automatic reset
Local status indication by dual colour LED’s
Remote panel indicator
Alarm status indication via in-built c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and AS/NZS
1768:2003
CONNECTION DIAGRAM
NOTE: This device must be installed by a Qualified
Electrician
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-P130-3DRI new.docx
24 April 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-120-3P/NEM
Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral Earth Monitoring
CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
less than 810V
Imax
Response time
Relay Contacts
Surge Reset
120kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or Neutral &
Earth both disconnected
the relay de-energizes.
L1, L2, L3, N-E
(LED ON = healthy)
LED’s (4)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
155(W) x 105(D) x 85(H)
GENERAL DESCRIPTION
The TLP 120-3P/NEM is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP120-3P/NEM is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3 modes.
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
2
Plug in 2.5mm
Red LED’s
Mild Steel (Powder coated)
155 (W) x 105 (D) x 85 (H)
850 grams
DIN 43880 Standard DIN Rail
The TLP-120-3P/NEM now offers a Neutral to Earth protection
monitoring circuit (NEMON) which until now has not been
available. The NEMON circuit ensures that all 3 modes of
protection are active and offers a fully monitored and reliable
protection device.
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP 3P/NEM.
FEATURES
REMOTE RELAY OUT
RELAY OUT
1 = N/O
2 = COMM
3 = N/C
1 2 3
TLP-120-3P/NEM
THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR
L1
L2
L3
NE
SUPPLY
L1
L2
L3
N
E
LOAD
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Neutral to Earth Monitor
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2003
NOTE: This device must be installed by a Qualified
Electrician.
CONNECTION
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-120-3P_NEM new.docx
12 January 2010
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-160-3P
Transtech Lightning Protector - 415V Three Phase, 3 Mode
CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
less than 810V
Imax
Response time
Relay Contacts
Surge Reset
160kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or MOV failed
the relay de-energizes.
L1, L2, L3, N-E
(LED ON = healthy)
LED’s (4)
GENERAL DESCRIPTION
The TLP 160-3P is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
The TLP160-3P is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3 modes.
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
2
Plug in 2.5mm
Red LED’s
Mild Steel (Powder coated)
155 (W) x 105 (H) x 85 (D)
850 grams
DIN 43880 Standard DIN Rail
3 2 1
TLP-120-3P
THREE PHASE TRANSIENT PROTECTOR
L1
L2
L3
NE
SUPPLY
L1
L2
L3
N
E
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
REMOTE RELAY OUT
RELAY OUT
1 = N/O
2 = COMM
3 = N/C
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
LOAD
Low “let thru” voltage
Designed and manufactured to ISO 9001
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2003
NOTE: This device must be installed by a Qualified
Electrician.
CONNECTION
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-160-3P new.docx
27 June 2011
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-160-3P/NEM
Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral Earth Monitoring
CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
less than 810V
Imax
Response time
Relay Contacts
Surge Reset
160kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or Neutral &
Earth both disconnected
the relay de-energizes.
L1, L2, L3, N-E
(LED ON = healthy)
LED’s (4)
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
155(W) x 105(D) x 85(H)
GENERAL DESCRIPTION
The TLP 160-3P/NEM is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
The TLP160-3P/NEM is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3 modes.
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
2
Plug in 2.5mm
Red LED’s
Mild Steel (Powder coated)
155 (W) x 105 (D) x 85 (H)
850 grams
DIN 43880 Standard DIN Rail
The TLP-160-3P/NEM now offers a Neutral to Earth
protection monitoring circuit (NEMON) which until now has not
been available. The NEMON circuit ensures that all 3 modes
of protection are active and offers a fully monitored and
reliable protection device.
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP 3P/NEM.
FEATURES
REMOTE RELAY OUT
RELAY OUT
1 = N/O
2 = COMM
3 = N/C
1 2 3
TLP-160-3P/NEM
THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR
L1
L2
L3
NE
SUPPLY
L1
L2
L3
N
E
LOAD
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Neutral to Earth Monitor
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2003
NOTE: This device must be installed by a Qualified
Electrician.
CONNECTION
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-160-3P_NEM new.docx
12 January 2010
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-240-3P
Transtech Lightning Protector - 415V Three Phase, 3 Mode
CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
less than 810V
Imax
Response time
Relay Contacts
Surge Reset
240kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
Phase loss or MOV failed
the relay de-energizes.
L1, L2, L3,
(LED ON = healthy)
LED’s (4)
GENERAL DESCRIPTION
The TLP 240-3P is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
The TLP 240-3P is a true 3 mode parallel connected
protection device offering 3 levels of kA rating in all 3 modes.
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
2
Plug in 2.5mm
Red LED’s
Mild Steel (Powder coated)
155 (W) x 105 (H) x 85 (D)
850 grams
DIN 43880 Standard DIN Rail
3 2 1
TLP-240-3P
THREE PHASE TRANSIENT PROTECTOR
L1
L2
L3
NE
SUPPLY
L1
L2
L3
N
E
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
REMOTE RELAY OUT
RELAY OUT
1 = N/O
2 = COMM
3 = N/C
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
LOAD
Low “let thru” voltage
Designed and manufactured to ISO 9001
Internally protected – automatic reset
Local status indication by LED’s
Remote status indication c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
NOTE: This device must be installed by a Qualified
Electrician.
CONNECTION
(CABLES 16sq/mm AS SHORT AS POSSIBLE)
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-240-3P new.docx
27 June 2011
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL: TLP-150-3M/CAT B
Transtech Lightning Protector - 415V Three Phase, 3 Mode
TECHNICAL DATA
Normal working voltage
Minimum working voltage
Maximum working voltage
Working Freq.
Peak let thru volts
Maximum mains current
415VAC rms
328VAC rms
476VAC rms
40 - 60Hz
<800V
Category
In (Crest current)
Imax (Max discharge current)
Response time
Surge Reset
AS/NZS 1768 Cat B
60kA (8/20uS)
150kA (8/20uS)
Less than 25nS
Automatic
Unlimited (parallel connected)
Must be fuse protected over 100A Mains
SPECIAL FEATURES
LED Indication
LED’s ON = TLP healthy
LED OFF = TLP repair
Changeover volt-free
Relay Output
GENERAL SPECIFICATION
FUSE/MCB
PROTECTION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Dimensions
Weight
Mounting
-40 to +70 Deg C
2
2
16mm solid max / 10mm flex max
N/A
Green LED’s
Aluminium (Powder coated)
95.5(W) x 72(H) x 108(L)
700 grams
DIN 43880 Standard DIN Rail
GENERAL DESCRIPTION
The TLP-150-3M/CAT B is a lightning and transient protector
which provides protection for electrical / electronic equipment
connected to three phase distribution systems. The mains borne
transient voltages may occur as a result of lightning strikes or the
switching of large inductive / capacitive loads.
The TLP-150-3M/CAT B is a parallel device for Cat B applications
and should be installed as close as possible to the supply being
protected. It is recommended that connecting cables be kept
shorter than 300mm.
The TLP-150-3M/CAT B is a true 3 mode protection device with
an Imax rating of 150kA for Cat B applications.
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP 150-3M.
FEATURES
TLP-XXX-3M/CATB
♦
♦
♦
♦
♦
♦
3PH 415V PROTECTION
CAT B
L1 L2 L3
N E
LOAD
SIDE
SUPPLY
L1 SIDE
L2
L3
N
E
L1
L2
L3
N
E
♦
♦
♦
♦
Low “let thru” voltage
Designed and manufactured to ISO 9001
Certified for BER Projects
Internally protected – automatic reset
LED status indication for power loss or fault
Designed to pass IEC 616431-1:2005 and AS/NZS
1768:2003
Long lifetime, fully lacquered PCB’s
CE Marking / C-tick N 2909
Full 3 mode protection
DIN 43880 compliant
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:/Docs/word/DataSheets/TLP-150-3M/CATB
th
14 October 2009
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
d
Subject to change without notice
MODEL TLP-DSI
Direct Status Indicator
TECHNICAL DATA
The TLP-DSI is powered directly from the Remote
Indicator (RI) output of Transtech TLP any High
Energy TLP unit which incorporates the unique
Remote Indicator circuitry.
Status LEDs
3 x RED
GENERAL SPECIFICATION
Operating Temp.
Connection
Housing Material
Dimensions
Weight
Mounting
GENERAL DESCRIPTION
The TLP-DSI is a self-powered remotely mounting
status indicator which mirrors the status LEDs on
Transtech’s High Energy TLP’s which have a unique
remote Indicator (RI) output fitted.
-25 to 70 degrees C
3 way 2.5mm2 plug-off
ABS.
48 x 48 x 60 mm
25gm nominal
Through panel mount
The LEDs of the TLP-DSI match their respective
status LED on the monitored TLP unit. A unique circuit
design means that only 3 wires are required to display
the status of any one of the monitored TLP LEDs.
TRANST ECH
The length of the 3 core cable between the TLP-xxx
and its TLP-DSI should be no more than a maximum
of 5 meters.
TLP-DSI
Max 5 mtr
3 core cable 0.5 sqmm
REMOTE STATUS OUT
REMOTE RELAY OUT
FEATURES
Model No
TLP-40-3P
TRANSTECH
UNIT
HEALTHY
3
2
1
Rem ote Alarm
1 = N/O | 2 = COMM | 3 = N/C
♦
♦
♦
♦
♦
♦
♦
POWER
ON
(Repl ace if OFF)
THREE PHASE
TRANSIENT PROTECTOR
L1 L2 L3
CAT C
V = 240V
In = 40kA
Im ax = 120kA
N E
LOAD
L1
L2
L3
N
E
Designed and manufactured to ISO 9001
Small size 48mm x 48mm panel mount unit
3 bright, easy to read LEDs
Status LEDs match those of the TLP LEDs
Easy to connect - only 3 wires
Plug-off terminals
No setup required.
CONNECTION
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
PAGE Page 1 of 1 ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-DSI.doc
Confidential
Page 1
March 12, 2013
DATA SHEET
d
Subject to change without notice
MODEL TLP-PSI
Powered Remote Status Indictaor
TECHNICAL DATA
Power Supply:
VA Rating :
120, 220/240 +/- 15%
Typically 1.3VA
Status LEDs:
Power
Healthy
Fault
Output:
BLUE
RED
YELLOW
Relay volt free contact
GENERAL SPECIFICATION
Operating Temp.
Power Terminals
Sense Terminals
Relay Output Term.
Indicators
Housing Material
Dimensions
Weight
Mounting
GENERAL DESCRIPTION
-25 to +70 degrees C
2
Plug in 1.5mm
2
Plug in 1.5mm
2
Plug off 2.5mm
Blue, Red, Yellow LEDs
ABS
48 x 48 x 60
50gm nominal
Through panel mount
The TLP-PSI is a 48mm x 48mm AC powered, status
indicator which may be connected to any TLP product
which incorporates a status output relay. The TLP-PSI
can be mounted in a convenient location at some
distance from the associated transient protection
device.
The TLP-PSI uses a transformer isolated 24V DC to
monitor the TLP status (fault) relay, it has three status
LEDs;
BLUE
= Power OK
RED
= Healthy
YELLOW
= Faulty (replace)
TRANST ECH
TLP-PSI/240V
Supply
Neutral
120Vac or 240Vac
Line
REMOTE RELAY OUT
REMOTE RELAY OUT
FEATURES
Model No
TLP-40-3P
TRANSTECH
UNIT
HEALTHY
♦
♦
♦
♦
♦
♦
3
2
1
Rem ote Alarm
1 = N/O | 2 = COMM | 3 = N/C
POWER
ON
(Repl ace if OFF)
THREE PHASE
TRANSIENT PROTECTOR
L1 L2 L3
SUPPLY
L1
L2
L3
N
E
CAT C
V = 240V
In = 40kA
Im ax = 120kA
N E
♦
LOAD
Designed and manufactured to ISO 9001
Small size 48mm x 48mm panel mount unit
3 bright, easy to read LEDs
Easy to connect
Plug-off terminals
Boxed (shrouded) AC connector
No setup required.
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
PAGE Page 1 of 1 ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-PSI.docx
Confidential
Page 1
March 7, 2013
DATA SHEET
Subject to change without notice
MODEL :-TLP-415P/E-DIN
Transtech Lightning Protector (no Neutral) - CAT B
TECHNICAL DATA
Voltage rating
Normal working voltage
415V
Max. working volts
480V RMS
Working Freq.
40 - 60 Hz
Peak let thru volts
710V
Protection Modes
Phase -Earth ONLY
Surge Rating
20kA,
Mass Surge Material
60kA 8/20uSecs
Meets Surge Ratings to AS/NZS 1768-1991
IEEE C 62.41, UL 1449
Earth Leakage
Approx 500uA
Operating Current
N/A in parallel
L x H x W = 112mm x 75mm x
45mm
GENERAL SPECIFICATION
GENERAL DESCRIPTION
Operating Temp
Storage Temp
Humidity
Indication
Terminals
The TLP-415P/E-DIN series is a lightning and power
transient arrester which provide voltage surge limitation to
power electrical devices connected to the mains power
supply.
The TLP-415P/E-DIN provides effective protection by
clamping the over voltage to a safe level. Three (3)
indicators show if the TLP-415P/E-DIN is “healthy” and
providing protection. Should one(1) indicator go off
replacement should be done as soon as possible if ALL
three indicators are off the device must be replaced
IMMEDIATELY.
The TLP-415P/E-DIN must always be installed on the load
side of a fuse or MCB.
The TLP-415P/E-DIN can be mounted directly on to “G” or
“DIN” rails (DIN 46277-1 and 46277-3)
Housing Material
Mounting Style
Dimensions
Weight
-20 to 70 Deg C
-55 to 75 Deg C
0 - 90% RH
3 Neon indicators
Self opening 0.5 - 10mm
20 - 6 AWG
KRILEN / AL cover
DIN or G rail
112mm x 75mm x 45mm
195 grams
L1 L2 L3
BENEFITS:-
EARTH
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Protection between 3 Phases – Earth
Fast snap on DIN rail mounting
26kA discharge capacity per line
Location Category B to AS 1768
CE / C-tick marking
♦
Ensure that the Earth is appropriately terminated at
all times. Ensure that the all Phases are at 0V
potential before removing the unit for service.
*** CAUTION ***
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-415p e.din new.docx
Confidential
August 24, 2011
20 AMP Series Filter 23mm WIDE
Model: TLP-SF20-SL-240V
Model: TLP-SP20-SL-240V
www.transtech.com.au
TRANSTECH ELECTRONIC CONTROLS
Electronic Transient Surge Protection
UNIQUE FEATURES:
Slimmest 20Amp Model available
3rd Party Tested to IEC 61643-1:2005
(PASSED)
High Fault Rating 54kA Mass
Metal Hosuing
Front LED
Australian Designed and Manufactured
Over 15,000 Installed Australia Wide
Transtech Electronic Controls Pty Ltd
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: (03) 9330-3624
Info@transtech.com.au
Also in Melbourne - Sydney – Brisbane – Adelaide
TRANSTECH
DATA SHEET
d
Subject to change without notice
MODEL :-TLP-SF20SL-240V
Transtech Lightning Protector/Surge Filter - 20Amp for 240Vac
TECHNICAL DATA
Voltage rating
Normal working voltage
240V RMS
275V RMS
40 - 60 Hz
710 V (typical 1 pulse)
Ph-N, Ph-E, N-E
Max. Working volts
Working Freq.
Peak let thru volts
Protection Modes
Surge Rating;Imax (max discharge current)42kA (8/20msec) @ 75%
24kA
Iin (crest current)
Meets Surge Ratings to AS/NZS 1768:2003
IEEE C 62.41, UL 1449
Tested & Pass to
IEC 61643.1:2005
Surge Filter
Inductor Type
Common Mode 20A choke
Capacitors
X and Y
Cut-off Frequency
Less than 1kHz (-3dB loss)
Attenuation
(60dB) 5MHz
Earth Leakage
Approx. 500uA
Operating Current
3mA nominal
Loss
Less than 2Watts
Continuous Current
20 Amps
L x H x W = 112mm x 75mm x 23.5mm nom.
GENERAL DESCRIPTION
The TLP-SF20SL series are lightning and power surge
transient arrestors with surge filtering. These provide
voltage limitation and filtering of transients for sensitive
electronic devices connected to the mains power supply.
The TLP-SF20SL provides effective protection via a three
stage circuit. The input stage limits the over-voltage
excursion, the second stage series surge filter restricts the
rate of rise of voltage (dV/dt) of any transient over-voltage
and the final stage clamps the output voltage to a safe
level.
The TLP-SF20SL must always be installed on the load
side of a fuse rated at 20 amps or less.
The TLP-SF20SL can be mounted directly on to “G” or
“DIN” rails (DIN 46277-1 and 46277-3)
GENERAL SPECIFICATION
Operating Temp
Storage Temp
Humidity
Terminals
-35 to 70 Deg C
-55 to 90 Deg C
0 - 90% RH
Self opening 0.5 – 4sq mm
Housing Material
Mounting Style
Dimensions (LxHxW)
nom.
Weight
MS cover/ ABS base
DIN or G rail
112mm x 75mm x 23.5mm
175 grams
INPUT
POWER
UNIT HEALTHY
LED
BENEFITS:♦
♦
♦
LINE
CB / FUSE
L N E
♦
♦
♦
♦
♦
♦
♦
♦
SYSTEM
HEALTHY
RCD DEVICE
TLP-SF20SL
TLP-SF
L N E
LOAD
OUTPUT POWER
CLEAN
Slim 23mm wide metal housing.
Low “let thru” voltage
Series inductor to control rate of voltage
rise
Protection between all lines
System Healthy Indicator - LED
Fast snap on DIN rail mounting
24kA discharge capacity per line
For location Cat B to AS 1768:2003
Tested & Passed to IEC 61643-1:2005
Designed to IEEE C 62.41 (UL1449)
Designed and manufactured in Australia to
ISO 9001
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
PAGE Page 1 of 2 ISSUE A / Rev C
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SF20SL-240V revc.docx
Confidential
Page 1
November 2, 2011
DATA SHEET
Subject to change without notice
MODEL :-TLP-SF20RI-240V
Transtech Lightning Protector/Filter - 20Amp for 240Vac with Relay
TECHNICAL DATA
Voltage rating
Max. working volts
Working Freq.
Peak let thru volts
Protection Modes
Surge Rating:
Imass
Imax
Iin
Operating Burden
Meets Surge Ratings to
Filter
Inductor Type
Capacitors
Attenuation
Earth Leakage
Operating Current
Maximum Current
Normal working voltage
220 - 250V RMS
275V RMS
40 - 60 Hz
710V (single pulse)
Ph-N, Ph-E, N-E
108kA
72kA
48kA
Approx 7mA
AS/NZS 1768:2003
IEEE C 62.41:2005UL 1449
Common Mode 20A choke
X and Y
(60dB) 5MHz
Approx 500uA
20 Amps
22 Amps
GENERAL DESCRIPTION
The TLP-SF20RI series is a series of lightning and power
transient arrestors with filtering + LED and relay output
which provides voltage surge limitation and filtering to
sensitive electronic devices connected to the mains power
supply and rated up to 20 amps.
Other Features
Relay Output
Form C 5A continuous
(Relay fails to safe position)
Plug-in 0.5 – 2.5mm
Relay Terminals
The TLP-SF20RI provides effective protection by clamping
the over voltage and via the series filter reducing the rate of
rise of the clamped voltage to a safe level.
If a fault occurs within the TLP-SF20RI the “healthy LED will
extinguish and the relay will de-energize).
GENERAL SPECIFICATION
Operating Temp
Storage Temp
Humidity
Terminals
Housing Material
Mounting Style
Dimensions (HxWxD)
Weight
-35 to 70 Deg C
-55 to 75 Deg C
0 - 90% RH
Self opening 0.5 – 4 sq mm
Mild Steel – DIN clip feet
DIN rail
120mm x 52mm x 80mm
195 grams
INPUT SUPPLY
L
N
E
The TLP-SF20RI must always be installed on the load side
of a protective device rated at 20 amps or less.
The TLP-SF20RI can be mounted directly on to “DIN” rails
(DIN 46277-1)
BENEFITS:-
ALARM OUTPUT
INPUT
♦
♦
♦
N/O COM N/C
♦
♦
♦
♦
♦
♦
♦
♦
RELAY
Power
TLP-SF20RI-240
SERIES FILTER SURGE PROTECTOR
Fault
OUTPUT
TRANSTECH
L
N
E
OUTPUT CLEAN SUPPLY
Low “let thru” voltage
Series filter to control rate of voltage rise
Protection between all lines (diff & common
mode)
Power “ON” indication
Unit “HEALTHY” indication (with relay)
Fast snap on DIN rail mounting
Designed for MEN Systems
Location Category B to AS 1768:2005
Tested to IEEE C 62.41:2005 & compliant)
Designed and manufactured to ISO 9001
CE / C-tick marking
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
PAGE Page 1 of 1 ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SF20RI-240.doc
Confidential
Page 1
8/9/2012
DATA SHEET
MODEL :-TLP-SP20SL-275
Transtech SERIES/PARALLEL Lightning Protector - 20Amp for 275V
TECHNICAL DATA
Voltage rating
Normal working voltage
240V DC/AC
275V DC/AC
DC - 60 Hz
Max. Working volts
Working Freq.
Rated Current
20 Amps for series connect
Unlimited for parallel connect
Peak let thru volts
Protection Modes
Surge Rating;-
900 V
Ph-N, Ph-E, N-E
Ph-N, 24kA, 8/20μS
Ph-E, 24kA, 8/20μS
N-E, 24kA, 8/20μS
72kA
Approx 500uA
20 Amps
Imax
Earth Leakage
Continuous Current
(see above re series/parallel)
GENERAL DESCRIPTION
Meets Surge Ratings to AS/NZS 1768:2003
IEEE C 62.41, UL 1449
IEC 61643.1:2005
GENERAL SPECIFICATION
Operating Temp
Storage Temp
Humidity
Terminals
-35 to 70 Deg C
-55 to 90 Deg C
0 - 90% RH
Self opening 0.5 – 4sq mm
Housing Material
Mounting Style
Dimensions (LxHxW)
Weight
M/Steel cover / ABS base
DIN or G Rail
112mm x 75mm x 23.5mm
175 grams
SERIES
INPUT
POWER
UNIT HEALTHY
LED
The TLP-SP20SL can be mounted directly on to “G” or
“DIN” rails (DIN 46277-1 and 46277-3)
BENEFITS:OUTPUT
TO LOAD
UNLIMITED amps
FUSES
Max 20amps
L N E
UNIT HEALTHY
LED
SYSTEM
HEALTHY
L N E
SYSTEM
HEALTHY
L N E
The TLP-SP20SL must always be installed on the load
side of a fuse rated at 20 amps or less.
PARALLEL
INPUT
POWER
FUSES
Max 20amps
TLP-SP20SL
The TLP-SP20SL range is either a series or parallel
connected lightning and power transient arrestor. The
range provides voltage surge limitation for sensitive
electronic devices connected to the mains power supply.
TLP-SP20SL
L N E
OUTPUT
TO LOAD
MAX 20amps
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Slim 23mm wide metal housing.
Low “let thru” voltage
Protection between all lines
System Healthy Indicator
Fast snap on DIN rail mounting
24kA discharge capacity per line
For location Cat B to AS 1768:2003
Tested to IEC 61643-1:2005
Tested to IEEE C 62.41 (UL1449)
Designed and manufactured in Australia to
ISO 9001
CONNECTION SCHEDULE
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
PAGE 1 / 1
ISSUE A REV B
www.transtech.com.au
TRANSTECH ELECTRONIC CONTROLS
Low Cost Surge Protection
Transtech Electronic Controls Pty Ltd
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: (03) 9330-3624
Info@transtech.com.au
Also in Melbourne - Sydney – Brisbane – Adelaide
TRANSTECH
DATA SHEET
Subject to change without notice
MODEL :- TLP-V60/275/S
Transtech Lightning Protector - 240V Plug-in Protectors CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
185VAC rms
275AC rms
40 - 60Hz
less than 1000V
Imax
Response time
Relay Contacts
Surge Reset
60kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
MOV failed the relay
de-energizes.
L1, L2, L3, flag type
Indicator
GENERAL DESCRIPTION
The TLP-V60/275S is a “new series” PLUG-IN lightning and
transient protector which provides protection for electrical /
electronic equipment connected to three phase distribution
systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
-40 to +80 Deg C
2
The TLP-V60/275S is a single mode parallel connected
protection device offering 60kA single mode but for all three
phases. see “1 Pole N/E” version Fig below.
2
35mm solid max / 10mm flex max
2
Plug in 2.5mm
Green/Red mechanical flag
Thermoplastic UL94-V-O
IP-20
18 (W) x 60 (H) x 90 (D)
850 grams
DIN 43880 Standard DIN Rail
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
LOAD SIDE
SUPPLY SIDE
L1
L2
L3
FUSE/MCB
PROTECTION
L1
L2
L3
L
TRANSTECH
TLP-V60
N/PE
L
N
L
TRANSTECH
TRANSTECH
TRANSTECH
L
L
TRANSTECH
TRANSTECH
TLP-V60 TLP-V60
TLP-V60 TLP-V60 TLP-V60
PE
PE
NOTE: This device must be installed by a Qualified
Electrician.
N
E
N
E
1 Pole N/E
1 Pole N+E
Designed and manufactured to ISO 9001
Local status indication by mechanical flag
Remote status indication by c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Available in 1P or 2P or 3P bases
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
3 Pole + E
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275s.docx
01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-V60/275/SM
Transtech Lightning Protector - 240V Plug-in Protector Range CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
185VAC rms
275AC rms
40 - 60Hz
less than 1000V
Imax
Response time
Relay Contacts
Surge Reset
60kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
MOV failed the relay
de-energizes.
L1, L2, L3, flag type
Indicator
GENERAL DESCRIPTION
The TLP-Vxx/275/S is a “new series” PLUG-IN lightning and
transient protector which provides protection for electrical /
electronic equipment connected to three phase distribution
systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
-40 to +80 Deg C
2
The TLP-V60/275SM is the replacement plug-in module
single mode parallel connected 60kA protection device.
2
35mm solid max / 10mm flex max
2
Plug in 2.5mm
Green/Red mechanical flag
Thermoplastic UL94-V-O
IP-20
18 (W) x 60 (H) x 90 (D)
850 grams
DIN 43880 Standard DIN Rail
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
LOAD SIDE
SUPPLY SIDE
L1
L2
L3
FUSE/MCB
PROTECTION
L1
L2
L3
L
TRANSTECH
TLP-V60
N/PE
L
N
L
TRANSTECH
TRANSTECH
TRANSTECH
L
L
TRANSTECH
Designed and manufactured to ISO 9001
Local status indication by mechanical flag
Remote status indication by c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Available in 1P or 2P or 3P bases
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
TRANSTECH
TLP-V60 TLP-V60
TLP-V60 TLP-V60 TLP-V60
PE
PE
NOTE: This device must be installed by a Qualified
Electrician.
N
E
N
E
1 Pole N/E
1 Pole N+E
3 Pole + E
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275sm.docx
01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-DS60/275-2V
Transtech Lightning Protector - 240V 1P+N E Protector 60kA CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
185VAC rms
275AC rms
40 - 60Hz
less than 1000V
Imax
Response time
Relay Contacts
Surge Reset
100kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
MOV failed the relay
de-energizes.
Flag type
Indicator
GENERAL DESCRIPTION
The TLP-V60/275S is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to a single phase distribution system.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
The TLP-V60/275S is a single mode parallel connected
protection device offering 60kA single mode L-N and L-E(PE)
(see middle Fig bottom left).
-40 to +80 Deg C
2
2
35mm solid max / 10mm flex max
Plug in 2.5mm2
Green/Red mechanical flag
Thermoplastic UL94-V-O
IP-20
36 (W) x 60 (H) x 90 (D)
850 grams
DIN 43880 Standard DIN Rail
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
FEATURES
LOAD SIDE
SUPPLY SIDE
♦
♦
♦
♦
♦
♦
♦
♦
L1
L2
L3
FUSE/MCB
PROTECTION
L1
L2
L3
L
TRANSTECH
TLP-V60
N/PE
L
N
TRANSTECH
TRANSTECH
L
TRANSTECH
L
L
TRANSTECH
TRANSTECH
TLP-V60 TLP-V60
TLP-V60 TLP-V60 TLP-V60
PE
PE
NOTE: This device must be installed by a Qualified
Electrician.
N
E
N
E
1 Pole N/E
1 Pole N+E
Designed and manufactured to ISO 9001
Local status indication by mechanical flag
Remote status indication by c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Available in 1P or 2P or 3P
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
3 Pole + E
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-ds60-275-2vs.docx
01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-V100/275
Transtech Lightning Protector - 240V 1P Protector 100kA CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms
185VAC rms
275AC rms
40 - 60Hz
less than 1000V
Imax
Response time
Relay Contacts
Surge Reset
100kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
MOV failed the relay
de-energizes.
L1, L2, L3, flag type
Indicator
GENERAL DESCRIPTION
The TLP-V100/275S is a “new series” lightning and transient
protector which provides protection for electrical / electronic
equipment connected to three phase distribution systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
The TLP-V100/275S is a single mode parallel connected
protection device offering 60kA single mode.
-40 to +80 Deg C
2
2
35mm solid max / 10mm flex max
2
Plug in 2.5mm
Green/Red mechanical flag
Thermoplastic UL94-V-O
IP-20
36 (W) x 60 (H) x 90 (D)
850 grams
DIN 43880 Standard DIN Rail
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
LOAD SIDE
SUPPLY SIDE
L1
L2
L3
FUSE/MCB
PROTECTION
L1
L2
L3
L
TRANSTECH
L
TRANSTECH
TLP-V100 TLP-V100
NOTE: This device must be installed by a Qualified
Electrician.
N
E
N
E
Designed and manufactured to ISO 9001
Local status indication by mechanical flag
Remote status indication by c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Available in 1P or 2P or 3P
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
1 Pole N+E
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v100-275.docx
01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-DS60/275/3V
Transtech Lightning Protector – 3 x 240V Plug-in Protectors CAT C or less
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
240VAC rms L – E(PE)
185VAC rms
275AC rms
40 - 60Hz
less than 1000V
Imax
Response time
Relay Contacts
Surge Reset
60kA (8/20uS)
Less than 25nS
SPCO (1 amp @240Vac)
Automatic
Unlimited (parallel connected)
Must be fuse protected over
100A Mains
SPECIAL FEATURES
Relay Output
MOV failed the relay
de-energizes.
L1, L2, L3, flag type
Indicator
GENERAL DESCRIPTION
The TLP-DS60/275 3V is a “new series” lightning and
transient protector which provides protection for electrical /
electronic equipment connected to three phase distribution
systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
-40 to +80 Deg C
2
The TLP-DS60/275 3V is a single mode parallel connected
protection device offering 60kA single mode for Line 1,2,3 and
Earth – see “3 Pole PE” version Fig below.
2
35mm solid max / 10mm flex max
2
Plug in 2.5mm
Green/Red mechanical flag
Thermoplastic UL94-V-O
IP-20
55 (W) x 60 (H) x 90 (D)
850 grams
DIN 43880 Standard DIN Rail
For mains supply of greater than 100A adequate HRC fuse or
MCB protection must be installed prior to the TLP-xxx- 3P
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
LOAD SIDE
SUPPLY SIDE
L1
L2
L3
FUSE/MCB
PROTECTION
L1
L2
L3
L
TRANSTECH
TLP-V60
N/PE
L
N
L
TRANSTECH
TRANSTECH
TRANSTECH
L
L
TRANSTECH
TRANSTECH
TLP-V60 TLP-V60
TLP-V60 TLP-V60 TLP-V60
PE
PE
NOTE: This device must be installed by a Qualified
Electrician.
N
E
N
E
1 Pole N/E
1 Pole N+E
Designed and manufactured to ISO 9001
Local status indication by mechanical flag
Remote status indication by c/o relay
High Energy designed pcb’s
CE Marking / C-tick N 2909
Available in 1P or 2P or 3P bases
DIN 43880 compliant
Designed to pass IEC 61643-1:2005 and
AS/NZS 1768:2005
3 Pole + E
CONNECTION DIAGRAM
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275s.docx
01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-LEC-A
Transtech Surge/ Lightning Counter
TECHNICAL DATA
Normal Working voltage
Minimum Working voltage
Maximum Working voltage
Working Freq.
Peak let thru volts
Maximum mains current
Imax
Response time
Relay Contacts
Surge Reset
110 - 240VAC
275AC
40 - 60Hz
100A
Automatic
SPECIAL FEATURES
Relay Output
Indicator
Battery
2 digit LCD
7.2V service life 1 year
GENERAL DESCRIPTION
The TLP-LEC-A is a “new series” lightning and transient
protector COUNTER with sensor for electrical / electronic
equipment connected to three phase distribution systems.
GENERAL SPECIFICATION
Operating Temp
Terminals
Remote Terminals
Indicators
Housing Material
Degree Protection
Dimensions (module)
Weight
Mounting
-40 to +80 Deg C
2.5mm
2 Digit LCD
Thermoplastic UL94-V-O
IP-20
18 (W) x 60 (H) x 90 (D)
125 grams
DIN 43880 Standard DIN Rail
LOAD SIDE
L1
L2
L3
N
E
FEATURES
♦
♦
♦
♦
CONNECTION DIAGRAM
SUPPLY SIDE
The TLP-LEC-A has a single current sensor for monitoring any
one phase – if three phases require monitoring ins tall
3 TLP-LEC-A units.
Designed and manufactured to ISO 9001
CE Marking / C-tick N 2909
Available in 1P only
DIN 43880 compliant
L1
L2
L3
N
E
SUPPLY SENSOR
L N
TLP-LEC-A
99
TRANSTECH
NOTE: This device must be installed by a Qualified
Electrician.
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-lec-a.docx 01 Feb 2013
PAGE 1 / 1
ISSUE A / Rev A
LOW VOLTAGE & BUS PROTECTORS – Cat B or A
www.transtech.com.au
TRANSTECH ELECTRONIC CONTROLS
Electronic Transient Surge Protection
NEW
Transtech Electronic Controls Pty Ltd
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: (03) 9330-3624
Info@transtech.com.au
Also in Melbourne - Sydney – Brisbane – Adelaide
TRANSTECH
DATA SHEET
Subject to change without notice
MODEL :- TLP-SL62-30D
Transtech Lightning Protector - Dual Channel
TECHNICAL DATA
Voltage rating (per channel)
Normal working volt
30V D.C. (peak AC)
Max. working volts
37V D.C. (peak AC)
Peak let thru volts
43.5V
Current/Resistance rating (per channel)
End to End resist.
6 ohms nominal
Max Current
500 mA
Discharge Current
2kA per mode or 4kA per
line (8/20usec)
Response rating
Response time:
Under 10nsec
93mm x 102.5mm x6.2mm
GENERAL SPECIFICATION
GENERAL DESCRIPTION
Operating Temp
Storage Temp
Connections
Housing Material
Mounting Style
Dimensions
Weight
The TLP-SL62 series of lightning and transient arrestors are
manufactured in a slim-line 6.2mm housing for those applications
where a high packing factor is required. The units provide
protection for electronic equipment connected to twisted pair
control and communication signal lines.
-10 to 70 Deg C
-40 to 105 Deg C
Self-opening 2.5mm/12AWG
Polyester PBT
DIN Rail
93.1(d) x 102.5(h) x 6.2(w)
52 grams
The TLP-SL62-30D has true three stage protection in all modes.
FEATURES
TLP-SL62-xxD
3
6
2
7
1
8
INPUT 1
CLEAN OUT 1
5
INPUT 2
4
CLEAN OUT 2
Transient Barrier
CAT B
Imax = 8kA
Voltage (Uc) =
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Dual channel unit
Two independent channels ( common earth)
3 stage protection
Low “let thru” voltage
Protection between ALL lines
Designed for 3kV impulse protection
Fast snap on DIN rail mounting
Fail to safe
Field proven technology
4kA discharge capacity per channel
Designed and manufactured to ISO 9001
6.2mm Slim Profile
300mm uncommitted earthing cable
CE marking / C-tick N2909
V
N2909
Earth
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL62-30D new.doc
Confidential
August 23, 2011
DATA SHEET
Subject to change without notice
MODEL :- TLP-SL12-xx
Transtech Lightning Protector for Low Voltages 05V – 48V
TECHNICAL DATA
Voltage rating
Normal working volt
Peak let thru volts
05,12,15,18,24,48V +/10,19,25,29,39,78V resp.
Current/Resistance rating
End to End resist.
Less than 6 ohm
Max Current
600 mA
Surge Current Imax
2 kA/mode (8/20uS)
Response rating
Response time
Under 10nsec
GENERAL SPECIFICATION GENERAL
SPECIFICATION
Operating Temp
Storage Temp
Terminals
Housing Material
Mounting Style
Dimensions
Weight
-10 to 60 Deg C
-55 to 75 Deg C
Self-opening 2.5mm/12AWG
KRILEN
DIN
110mm X 52mm X12mm
60 grams
GENERAL DESCRIPTION
The TLP-SL12-xx series is a very compact 12mm wide
lightning and transient arrester providing protection for
equipment connected to low voltage instrument loops by
limiting the transient over-voltage to less than twice the
normal working voltage.
The TLP-SL12-xx series provides protection between all
conductors, line to line and each line to earth. It is mounted
on to “DIN” rail (46277-3) and offers screen termination via
terminals and the earth via a 300 mm earth wire “tail”.
CABLE INPUT
1
2
3
4
2
4
1
2
3
4
1
3
INPUT
LINE
TRANSTECH
TRANSTECH
TLP-SL12-xx
INPUT
LINE
OUTPUT
LINE
OUTPUT
LINE
5
7
FEATURES
2
4
TLP-SL12-xx
SERIES
CONNECTION
1
3
PARALLEL
CONNECTION
CABLE INPUT
6
8
5
7
6
8
5
6
5
6
7
8
7
8
CABLE OUTPUT
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Protection between ALL lines
Fast snap on DIN rail mounting
Fail to safe status design
Field proven technology
Low line losses (volt drop)
Designed and manufactured to ISO 9001
High stacking density
C-Tick/ CE Compliant
IEC 1000-4-2 & EN50082
CONNECTION SCHEDULE
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL12-xx.docx
Confidential
November 6, 2012
DATA SHEET
Subject to change without notice
MODEL :- TLP-48HM-4W-240
Transtech Lightning Protector - Process Transmitter
Loop plus 240V Supply Protector
TECHNICAL DATA
Voltage Rating
Current Loop:
Supply:
22V – 48Vdc (black/black)
190-265Vac (blue/brown)
Current/Impedance Rating
End to End Impedance: N/A parallel connection
Max Current:
N/A parallel connection
Discharge Power:
Imax = 10kA (8-20uS wave)
Response rating
Response time:
EMC Compliance:
Field Bus:
Less than 10nS
EN50082 part 2
C-tick / CE compliant
31.25kbit/s
25mm Hex x 75mm c/- 250mm leads
GENERAL SPECIFICATION
Operating Temp:
Storeage Temp:
Humidity:
Termination wires:
(colour coding)
Housing Material:
Dielectric Strength:
Thread:
Weight:
Dimensions:
-20 to 60 Deg C
-40 to 80 Deg C
5% to 95% RH
(Non-condensing)
Flying Leads (250mm 1.0mm2)
Blue & Brown for 240vac supply
Black for 4-20mA signal
Green / Yellow for earth
ANSI 316 Stainless Steel
o
25 C, 50 kHz, 19kV/mm
a) 20mm ISO (M20 x 1.5)
b) ½” NPT
185g
75mm (L) x 25mm Hex
c/- 250mm coloured leads
GENERAL DESCRIPTION
The TLP-48HM-4W-240 lightning/transient protector provides
protection for field mounted transmitters or electronic devices mounted
in exposed areas. The TLP-48HM-4W-240 consists of a high speed
solid state switching network which protects all signal and supply lines
and common earth. The front end protection per line has a gas
discharge tube with a 10kA rating.
The housing material is ANSI 316 stainless steel with a 23mm flat for
assisting mechanical mounting. The unit is encapsulated in high
temperature casting epoxy. This epoxy offers high impact resistance
with excellent electrical properties and high temperature stability. The
standard male thread is the common 20mm conduit entry (20mm ISO,
M20 x 1.5), several other thread types are available upon request.
The TLP-48HM-4W-240 is designed to be added to standard
installations. Most field transmitters have two conduit entries, one is
used to connect the data cable, the spare can be used for the TLP48HM-4W-240 connection. Under most field installations no additional
connection boxes are required. Should no spare entry be available
then a simple conduit tee can be used as close as possible to the field
device.
The TLP-48HM-4W-240 connection is a simple parallel connection for
BOTH supply and signal lines (see connection schedule). Care must be
taken in the earthing of the green/yellow earth wire from the TLP48HM-4W-240.
This earth wire must be earthed to local
general/structural metal work, all leads to be kept as short as possible
at all times.
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
ESD Protection
Low “let thru” voltage
Protection between ALL lines (including 240vac supply)
Field proven technology
Simple field mounting
Field Buss compatible (4-20mA loop only)
Parallel Connection (No loop impedance)
Designed and manufactured to ISO 9001
C-Tick/CE compliant
Meets AS/NZS 1768:2003 Class B
Meets IEC 61643.1:2005 Class I & II
Auto resetting
High 10kA discharge
DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE.
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-48HM-4W-240rev.doc 1st January 2009
PAGE 1 / 1
ISSUE C / Rev A
DATA SHEET
Subject to change without notice
MODEL :- TLP-SL12-RS 485MB
Transtech Lightning Protector - RS-485 (Modbus Compatible)
TECHNICAL DATA
Voltage rating
Normal working volt
Peak let thru volts
Peak let thru volts
+/- 12V
19V @ 1p = 1A
24V @ 1p = 10A
Current/Resistance rating
End to End resist.
Less than 0.6 ohms
Max Current
1 Amp
Discharge Power
400W PPPD @ (8/20uS)
(Peak Pulse Power Discharge)
Response rating
Response time
Under 10nsec
GENERAL SPECIFICATION GENERAL
SPECIFICATION
Capacitance
Operating Temp
Storage Temp
Terminals
2.5mm/12AWG
Housing Material
Mounting Style
Dimensions
Weight
GENERAL DESCRIPTION
The TLP-SL12-RS 485MB is a very compact 12mm wide
lightning and transient arrester providing protection for
equipment connected to the Modbus RS 485 multi-point or
party line bus by limiting the transient over-voltage to less
than twice the normal working voltage.
@ 1mMz, 75pF
-10 to 60 Deg C
-55 to 75 Deg C
Self-opening
KRILEN
DIN
110mm X 52mm X12mm
60 grams
The TLP-SL12-RS 485MB provides protection between all
conductors, line to line and each line to earth. It is mounted
on to “DIN” rail (46277-3) and offers screen termination via
terminals and the earth via a 300 mm earth wire “tail”.
FEATURES
RS-485 BUS
L1 +ve
Screen
♦
♦
♦
♦
♦
L2 -ve
1
3
2
4
2
4
1
3
2
4
INPUT
LINE
TRANSTECH
TRANSTECH
TRANSTECH
TLP-SL12-RS485
1
3
2
4
INPUT
LINE
TRANSTECH
TLP-SL12-RS485
INPUT
LINE
TLP-SL12-RS485
INPUT
LINE
TLP-SL12-RS485
1
3
CLEAN
LINE
CLEAN
LINE
CLEAN
LINE
CLEAN
LINE
5
7
5
7
5
7
5
7
6
8
6
8
END OF LINE R
6
8
END OF LINE R
6
8
30 NODES
RS 485 STN
RS 485 STN
RS 485 STN
♦
♦
♦
♦
Low “let thru” voltage
Protection between ALL lines
Fast snap on DIN rail mounting
Fail to safe status design
High speed switch technology to prevent
signal attenuation
Low line losses (volt drop)
Designed and manufactured to ISO 9001
C-Tick/ CE Compliant
IEC 1000-4-2 & EN50082
RS 485 STN
CONNECTION SCHEDULE
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL12-RS485MB.docx
Confidential
November 6, 2012
DATA SHEET
Subject to change without notice
MODEL :- TLP-DNET
Transtech Lightning Protector - DeviceNet
TECHNICAL DATA
Voltage Rating Supply
Normal Working voltage
Max. Working voltage
Varistors voltage
Surge current
24V D.C.
31V D.C.
39V D.C.
1000A@(8/20uS)
Current/Resistance Rating
End to End resist.
Less than 0.2R
Max Current
Thin cable = 4Amp
Thick cable = 8 Amp
Discharge Power
300W PPPD@ (8/20uS
(dissipation per line)
Protection
Protection modes CAN-H to CAN-L, CAN-H to Screen
CAN-L to Screen, Screen to V-Screen to V+, V+ to VLine Capacitance
15pF
Breakdown Voltage
26.7V D.C. minimum
Clamp voltage
43.0V D.C. maximum @ (8/20uS)
GENERAL SPECIFICATION
Operating Temp
Storeage Temp
Terminals
2.5mm/12AWG
Housing Material
Mounting Style
Dimensions
Weight
1
2 3 4 5
V1 L S H V+
BUS CONNECTION
1
2 3 4 5
V1 L S H V+
BUS CONNECTION
The TLP-DNET provides very effective protection by
limiting the transient overvoltage to less than twice the
normal voltage on the supply and data lines.
KRILEN
DIN
75mm X 45mm X 30mm
120 grams
The TLP-DNET provides protection between all
conductors, Power/data line to line and line to earth.
X
V1
1
H
4
V+
5
L
2
S
3
1
2 3 4 5
V1 L S H V+
BUS CONNECTION
TRANSTECH
X
TLP-DNET
SUPPLY/CONTROLLER
S
3
1
2 3 4 5
V1 L S H V+
BUS CONNECTION
X
TLP-DNET
H
4
V+
5
CLEAN LINES
The TLP-DNET can be mounted on DIN rail and the earth
return in via a 5mm earth stud.
FEATURES
TRANSTECH
V1
1
L
2
BUS INPUT
TRANSTECH
SUPPLY/CONTROLLER
The TLP-DNET lightning and transient arrestor provides
protection for equipment connected to the DEVICENET
INTERFACE NETWORK.
-10 to 70 Deg C
-55 to 80 Deg C
Self opening
CAN bus
TRANSTECH
GENERAL DESCRIPTION
X
TLP-DNET
TLP-DNET
SUPPLY/CONTROLLER
SUPPLY/CONTROLLER
V1
1
V1
1
L
2
S
3
H
4
V+
5
L
2
S
3
H
4
V+
5
NODES
PSU NODE
PSU NODE
PSU NODE
PSU NODE
DeviceNET
STN
DeviceNET
STN
DeviceNET
STN
DeviceNET
STN
CONNECTION SCHEDULE
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
ESD Protection > 25kV
Low “let thru” voltage
Protection between ALL lines
Fast snap on DIN mounting
Fail to safe status design
IEC 1000-4-2 & EN50082
Ultra low capacitance data line
Field proven technology
Low line losses (volt drop)
Designed and manufactured to ISO 9001
High stacking density
C-Tick / CE Compliant
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-DNET new.docx
Confidential
August 25, 2011
COMMUNICATIONS PROTECTORS
www.transtech.com.au
TRANSTECH ELECTRONIC CONTROLS
Electronic Transient Surge Protection
Transtech Electronic Controls Pty Ltd
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: (03) 9330-3624
Info@transtech.com.au
Also in Melbourne - Sydney – Brisbane – Adelaide
TRANSTECH
DATA SHEET
Subject to change without notice
MODEL:- TLP-48/RJ45H-4
Transtech Lightning Protector – Ethernet RJ45
TECHNICAL DATA
Voltage rating
Normal working volt
Nominal Current
Clamping Volts
Impulse Clamping
Surge withstand Imax
Energy Level
48Volts
1 Amp or less
90Volts line to screen
< 600Volts (1kV/us)
0.3kA (8/20usec)
Less than 100 joules
Characteristics
Transmission Speed
Insertion Loss
Pins
100M bpss
< 3.0 dB at 100MHz
1 – 2 and 3 - 6
GENERAL DESCRIPTION
GENERAL SPECIFICATION
Insulation resistance
Connections
Operating Temp
Storage Temp
Mounting Style
Dimensions
Weight
> 10 Megohm
RJ45 Female / Female
-10 to 70 Deg C
-55 to 80 Deg C
DIN Rail Female to Female
85mm X 25mm X 40mm
62 grams
The TLP-48/RJ45H-4 lightning and transient arrestor
provides protection for Ethernet, Twisted Pair Cat 5 ISDN
and DSL Network Cables
The TLP-48/RJ45H-4 provides very effective protection by
limiting the transient over-voltage between the conductor s
of Netowrk cable pairs and the screen
The TLP-48/RJ45H-4 utilizes fast response gas filled
arrestors and Transorbs to provide low let thru voltages for
fast transient rise times. The use of low capacitance gas
filled arrestors ensures reliable operation at high
frequencies with low insertion losses.
FEATURES
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Two Stage protection
Protection between lines and screen
Suitable for 10BaseT and 100BaseT
Aluminium housing
Field proven technology
Low line losses
Designed and manufactured to ISO 9001
C-Tick/ CE Compliant
Complies with IEC 616431L21-2005
IMPORTED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-48_RJ45H4 new.docx
Confidential
August 25, 2011
DATA SHEET
Subject to change without notice
MODEL:- TLP-N/FF
Transtech Lightning Protector – Coax Bulkhead +Tag
TECHNICAL DATA
Voltage rating
Normal working volt
Nominal Current
Clamping Volts
Impulse Clamping
Surge withstand
Energy Level
70Volts
5 Amps or less
90Volts line to screen
< 600Volts (1kV/us)
20kA (8/20usec)
400 joules
RF Characteristics
RF Power
Insertion Loss
VSWR
50 Watts
< 0.2dB at 2GHz
1.07 : 1 @ 1GHz
1.10 : 1 @ 2GHz
GENERAL DESCRIPTION
GENERAL SPECIFICATION
Capacitance
Insulation resistance
Operating Temp
Storage Temp
Mounting Style
< 1.5pF
> 10 Megohm
-10 to 80 Deg C
-55 to 80 Deg C
Bulkhead/Type N
Female to Female
67mm X 25mm X25mm
80 grams
Dimensions
Weight
The TLP-N/FF lightning and transient arrestor provides
protection for coaxial lines for radio transmitters, receivers
or HF party line bus.
The TLP-N/FF provides very effective protection by
limiting the transient over-voltage between the inner
conductor of the coaxial cable and the screen
The TLP-N/FF utilizes fast response gas filled arrestors to
provide low let thru voltages for fast transient rise times.
The use of low capacitance gas filled arrestors ensures
reliable operation at high frequencies with low insertion
losses.
FEATURES
TLP-N/FF
12 mm
22 mm
♦
♦
♦
20 mm
56 mm
DIMENSIONS
25 mm
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Protection between line and screen
Bulkhead mounting with additional fixed
“bolt-thru” earth tag
Field proven technology
Low line losses
Designed and manufactured to ISO 9001
C-Tick/ CE Compliant
IEC 1000-4-2 & EN50082
AS 1768-2003
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-N_FF new.doc Confidential
August 20, 2011
DATA SHEET
Subject to change without notice
MODEL:- TLP-F/FF
Transtech Lightning Protector – Coax Type F Cables
TECHNICAL DATA
Voltage rating
Normal working volt
Nominal Current
Clamping Volts
Impulse Clamping
Surge withstand
Energy Level
70Volts
5 Amps or less
90Volts line to screen
< 700Volts (1kV/us)
20kA (8/20usec)
400 joules
RF Characteristics
RF Power
Insertion Loss
VSWR
50 Watts
< 0.5dB at 2GHz
< 1.3
GENERAL DESCRIPTION
GENERAL SPECIFICATION
Capacitance
Insulation resistance
Operating Temp
Storage Temp
Mounting Style
Dimensions
Weight
< 1.5pF
> 10 Gigohm
-10 to 80 Deg C
-55 to 80 Deg C
Type F
Female to Female
52mm X 25mm X25mm
50 grams
The TLP-F/FF lightning and transient arrestor provides
protection for coaxial lines for radio transmitters, receivers
or HF party line bus.
The TLP-F/FF provides very effective protection by
limiting the transient over-voltage between the inner
conductor of the coaxial cable and the screen
The TLP-F/FF utilizes fast response gas filled arrestors to
provide low let thru voltages for fast transient rise times.
The use of low capacitance gas filled arrestors ensures
reliable operation at high frequencies with low insertion
losses.
FEATURES
TLP-F/FF
12 mm
21 mm
22 mm
55 mm
DIMENSIONS
25 mm
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Protection between line and screen
Field proven technology
Low line losses
Designed and manufactured to ISO 9001
C-Tick/ CE Compliant
IEC616431:21
IEC 1000-4-2 & EN50082
AS 1768-2003
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-F_FF new.doc Confidential
August 20, 2011
DATA SHEET
Subject to change without notice
MODEL:- TLP-F/MF
Transtech Lightning Protector – Coax Type F Cables
TECHNICAL DATA
Voltage rating
Normal working volt
Nominal Current
Clamping Volts
Impulse Clamping
Surge withstand
Energy Level
70Volts
5 Amps or less
90Volts line to screen
< 700Volts (1kV/us/V)
20kA (8/20usec)
400 joules
RF Characteristics
RF Power
Insertion Loss
VSWR
50 Watts
< 0.5dB at 2GHz
<1.3
GENERAL DESCRIPTION
GENERAL SPECIFICATION
Capacitance
Insulation resistance
Operating Temp
Storage Temp
Mounting Style
Dimensions
Weight
< 1.5pF
> 10 Gigohm
-10 to 80 Deg C
-55 to 80 Deg C
Type F
Male to Female
52mm X 25mm X25mm
50 grams
The TLP-F/MF lightning and transient arrestor provides
protection for coaxial lines for radio transmitters, receivers
or HF party line bus.
The TLP-F/MF provides very effective protection by
limiting the transient over-voltage between the inner
conductor of the coaxial cable and the screen
The TLP-F/MF utilizes fast response gas filled arrestors to
provide low let thru voltages for fast transient rise times.
The use of low capacitance gas filled arrestors ensures
reliable operation at high frequencies with low insertion
losses.
FEATURES
TLP-F/MF
12 mm
20 mm
22 mm
56 mm
DIMENSIONS
25 mm
♦
♦
♦
♦
♦
♦
♦
♦
♦
Low “let thru” voltage
Protection between line and screen
Field proven technology
Low line losses
Designed and manufactured to ISO 9001
C-Tick/ CE Compliant
IEC616431:21
IEC 1000-4-2 & EN50082
AS 1768-2003
DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499
Design changes may occur in the interests of product performance & development E&OE
Page 1 of 1
ISSUE A / Rev A
I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-F_MF new.doc Confidential
August 20, 2011
TransTech Electronic Controls Pty Ltd
ABN 21 070 629 499
A GUIDE
TO SPECIFYING
ELECTRONIC SURGE PROTECTION DEVICES
Preface:
This document is meant as a guide to those involved in specifying, applying and/or approving electronic
transient protection devices. It is by no means a definitive paper on the types of transient surge protection
available nor in any way proposes to set out a particular manufacturer, type or technique.
This guide does not address “structural lightning protection” other than to direct the reader to the
Australian Standard AS NZS 1768:2005 and in particular to the proven techniques for effective structural lightning
design and installation. Good structural protection and earthing/bonding is an essential part of minimizing possible
effects from lightning transients.
The most important consideration for any Engineer specifying electronic transient protection is the “letthru” voltage as this is critical to the proper functioning of the electronic/electrical equipment it is intended to
protect following a transient. The critical considerations in specifying electronic transient protectors are:
1.
2.
3.
4.
5.
Be compatible with the system it is protecting
Survive transients and contain any fault condition arising
Have a low “let-thru” voltage for ALL conductor combinations
Not fail and leave the installation un-protected
Be correctly installed and maintained regularly.
1. Compatibility
The protector should not inhibit the systems normal operation if it operates
2. Survival & housing
Transients from a lightning strike (close proximity) can exceed 200,000 amps, however statistically
the average transient is approx 10,000 amps. The IEC Standard uses 10,000 amps as the accepted
“norm”, however AS1768 has adopted 70,000 amps therefore any protector at a point of entry
should have a rating equal to or exceeding 70,000 amps to meet the current Australian Standard.
It is recommended by the leading MOV suppliers that surge protectors incorporating such devices be
constructed of metal as a safety precaution Clause 7.9.2 of IEC61643-1:2005 addresses this aspect.
3. Let-thru voltage
The magnitude of the transient reaching the electronic/electrical equipment is critical and can cause
anything from data-corruption to flash-over and arcing damage. The suitable protector should
therefore offer a let-thru voltage less than the maximum voltage rating for the equipment (the
current IEC states 2.5kV as the minimum insulation level).
Transients occur between all conductors of a system – that is: Ph-N / Ph-E / N-E and in
instrumentation and data-line circuits both Common Mode and Differential Mode. Protectors need to
offer such levels of protection
4. Indication of failure
In-line protectors such as used for 120/240vac sub-circuit, instrumentation and/or data-lines are
inherently “self-revealing” upon a major transient as the circuit invariably goes open. In Main Board
protection systems it is essential to have an indication to warn of failure or degradation of the
protective devices, such indication should be both local visual and a relay output.
5. Installation
The performance of transient protectors depends upon correct installation as they are required to
manage high frequency waveforms, therefore the length and size of connecting cables must be
considered, as a guide refer to AS4070:1992. As a rule of thumb the larger the cross section and the
shorter the cable the better, 500mm of 6 sq mm cable is recommended as a minimum.
I:\Shared\Price Lists & data sheets\Transtech\Application Notes\surge protection guide.docx
Updated: 15/11/2011/
TransTech Electronic Controls Pty Ltd
ABN 21 070 629 499
SUGGESTED SPECIFICATION
1.1 Point-of-Entry Main & Sub Distribution Boards.
Provide lightning/transient surge suppression to the mains supply of the main
switchboard and each sub distribution board. Supply, install and connect a … insert
similar product of equivalent function and quality to the satisfaction of the
Engineer. Such rating to be no less than 70kA surge capacity according to IEC 61643.1 and
are to include all 3 phases plus Neutral and offer true 3 mode protection.
Manufacturer(s)…., or
The installation shall be strictly in accordance with the Manufacturers recommendations.
1.2 Final Sub Circuits
Where indicated on power circuit schedules a series filter surge protector shall be fitted
to protect individual circuits. The series filters shall be …. Insert manufacturer(s)…...or similar
product equivalent in function, size and quality to the approval of the Engineer. Rating shall be
no less than 24kA according to IEC 61643.1 and offer true 3 mode protection. The surge
device shall be compatible with any RCD protection and protect against high frequency noise
and transient surges in all modes (L-N, L-E, N-E). The series protectors shall be constructed to
meet UL 1449 and be Third Party tested to IEC61643.1.
Where alternatives are offered the tenderer shall provide sufficient data to prove that the
alternative complies with the specification.
All transient/surge protection devices shall be mounted to protrude thru the distribution
board escutcheon plate and shall have visible status indication. Where nominated such series
surge filters shall have in addition an incorporated relay that monitors the health of the
protection device and provides a volt-free changeover contact for monitoring by the Building
Management System (BMS).
I:\Shared\Price Lists & data sheets\Transtech\Application Notes\surge protection guide.docx
Updated: 15/11/2011/
TransTech Electronic Controls Pty Ltd
ABN 21 070 629 499
SURGE CURRENT CAPACITY & FUSING
REF: AS/NZS 1768:2005
1. INTRODUCTION
The committees of all International Standards, after years of research have decided that the average
indirect lightning surge is only 10kA, Standards Australia, however, via AS1768:2005 Table F1 states
70kA as a maximum indirect lightning surge value,
Transtech has therefore taken the decision to meet the higher level as detailed by Standards Australia
and as a consequence the main board of the TLP range of Surge Protectors is designed to withstand
multiple transient surges of 70kA and a single surge of 140kA.
NOTE: The fault rating assigned to a Mains Surge Protector is not to be confused with the switchboard
bus bar fault rating. A transient/lightning surge rating is based upon an 8/20micro second waveform
therefore a duration of only 28 microseconds.
2. DESIGN OF TRANSTECH MAINS PROTECTORS
Transtech Electronic Controls Pty Ltd has been designing and manufacturing electronic transient/surge
protectors since 1996 and has supplied some of Australia’s biggest Companies not to mention delivering
over 15,000 pcs of its 20Amp single phase series filters to the BER Project Australia Wide.
Based upon the preceding information, Transtech Electronic Controls Pty Ltd designs its
TLP Mains Surge Protectors with high quality 70micron copper board and accurately calculated track
sizing designs. Surge protectors with ratings above 70kA simply offer extended lifetimes to users.
3. PROTECTING A TLP MAINS PROTECTOR
Protection of a Mains Surge Protector is governed according to AS3000. It is a requirement to protect the
circuit with either an HRC Fuse or a MCB, the HRC Fuse or MCB size is determined firstly by the Fault
Rating of the Switchboard and secondly by the wire size supplying the TLP.
3.1.1.
SWITCHBOARD FAULT RATING
This refers to the bus bar fault level, therefore any protection device such as an HRC Fuse or
a MCB must be in accordance with suppliers ratings and application advice (an example
being Schneider Cascading & Enhanced Discrimination tables)
3.1.2.
WIRE SIZE
Transtech Electronic Controls Pty Ltd recommends the maximum size wire to connect a TLP
2
Mains Protector – that is 16 mm therefore according to AS3000 Table B2 the HRC Fuse or
MCB shall be 50 amps maximum.
3.1.3.
PROTECTION SELECTION (amp rating)
As per preceding comments, either an HRC Fuse or MCB is required to protect and provide
isolation for the Mains Surge Protector. The factors to be considered in the selection of a
suitable primary protection device are as per Clauses 3.1.1 and 3.1.2 above.
The current rating of the HRC or MCB should be between 25 amps and 50 amps.
I:\Shared\Price Lists & data sheets\Transtech\Application Notes\fault rating design and fuse sizes.docx
TransTech Electronic Controls Pty Ltd
ABN 21 070 629 499
SUMMARY.
A. Transtech Electronic Controls Pty Ltd follows AS1768:2005 and all other relevant Standards in its
designs and meets them regarding surge fault ratings.
B. Transtech Electronic Controls Pty Ltd Mains Surge Protectors cover all Category’s E / D / C / B / A
C. Transtech Electronic Controls Pty Ltd manufactures Mains Surge Protectors offering Surge Fault
ratings in excess of 70kA, these simply offer the user extended lifetime.
D. The fault ratings of the TLP Mains Surge Protectors should not be confused with switchboard bus bar
fault ratings.
E. All Transtech Mains Surge Protectors type TLP’s have internal MOV protection fuses suitable to break
100Amps.
F. The fault rating of a TLP Mains Surge Protector is based upon a very short time of 28 microseconds,
not to be confused with a typically 1sec rating as for switchboard Type Tests.
G. Transtech Electronic Controls Pty Ltd has been designing electronic surge protectors for over 16
years and accurately designs the circuit board layout in its TLP series to withstand a 70kA 8/20
microsecond surge.
H. PROTECTION TABLE:
TLP MODEL
RECOMMENDED
DEVICE
AMPS
COMMENT
TLP-SF20SL-240V
TLP-40-xP
TLP-80-xP
TLP-120-xP
TLP-160-xP
TLP-200-xP
TLP-240-xP
HRC
HRC
HRC
MCB
MCB
MCB
MCB
25
40
50
50
50
50
50
Single phase series filter
I:\Shared\Price Lists & data sheets\Transtech\Application Notes\fault rating design and fuse sizes.docx
MCB’s not tripped by transient
MCB’s not tripped by transient
MCB’s not tripped by transient
MCB’s not tripped by transient
Transtech Electronic Controls Pty Ltd
Australian Agent for:
HAZARDOUS AREA ENCLOSURES
HIGH SPEED SENSORS & TACHOS
ALARM ANNUCIATORS
ENCODERS AND TECHOS
HAZARDOUS AREA FLOW/TEMP/PRESSURE
PROXIMITY SENSORS & PE CELLS
Transtech Electronic Controls Pty Ltd
Also in Sydney – Brisbane – Adelaide
TRANSTECH
ABN 21 070 629 499
Perth - Melbourne
Perth Tel: (08) 9302-2044
Melbourne Tel: 0400 848-064
Info@transtech.com.au
Download