From Mains Power Supply to Low Volts & Communications www.transtech.com.au TRANSTECH ELECTRONIC CONTROLS Electronic Transient Surge Protection Transtech Electronic Controls Pty Ltd ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: (03) 9330-3624 Info@transtech.com.au Also in Melbourne - Sydney – Brisbane – Adelaide TRANSTECH TLP Transient Lightning Protection This is a TLP overview - contact sales for the full range of TLP protectors Process - Industrial - Mining - Commercial - Government - Factories - Research MAINS PROTECTORS CAT C, 20kV AND 20 kA - use TLP-80-3P, TLP-120-3P, TLP-160-3P CAT B, 6kV and 3kA - use TLP-8-1P/240 OR TLP-150-3P/CATB, AS 1768 IEEE C62 compliant VOLTAGE Nominal (Vrms) Maximum (Vrms) MODELS FIG 1 FIG 2 FIG 3 FIG 4 FIG 5 PEAK DISCHARGE CURRENT Per Mode 8/20usec (kA) MAX “LET-THRU” VOLTAGE Volts/Modes INDICATION Visual/Remote FIGURE No DIMENSIONS in mm 390 / 2 600 / 2 <600 / 3 <600 / 3 <600 / 3 <810 / 3 <810 / 3 <810 / 3 <810 / 3 <810 / 3 <810 / 3 <810 / 3 <710 / 3 <810 / 1 N/N N/N Y/Y Y/Y Y/Y Y / Y + FIG9 Y / Y + FIG9 Y / Y + FIG9 Y / Y + NEM Y / Y + NEM Y / Y + NEM Y / Y + NEM Y/Y Y/N Ref HO Ref HO FIG 1 FIG 1 FIG 1 FIG 1 FIG 1 FIG 1 FIG 3 FIG 3 FIG 3 FIG 3 FIG 4 FIG 4 FIG 9 FIG 10 FIGURE No DIMENSIONS in mm W H D 12.5 75 53 12.5 75 53 80 110 85 80 110 85 80 110 85 105 120 75 kA Low Cost DIN 1 PH (Cat A) TLP-8-1P/120V TLP-8-1P/240V High Spec DIN 1 PH (Cat C) TLP-40-1P TLP-80-1P TLP-120-1P High Spec DIN 3 PH (Cat C) TLP-P40-3DRI Compact series DIN profile TLP-P80-3DRI Remote status/Indication capable TLP-P120-3DRI High E-N Fault DIN 3 PH (Cat C) TLP-80-3P/NEM With unique N to E monitoring feature = NEM TLP-120-3P/NEM TLP-160-3P/NEM TLP-200-3P/NEM Compact Series DIN PROFILE (Cat A or B) TLP-150-3P/CAT B No neutral required for this model TLP-415P-E-DIN 120 / 240 / 240 / 240 / 240 / 240 / 240 / 240 / 415 / 415 / 415 / 415 / 415 / 415 / 150 275 275 275 275 275 275 275 475 475 475 475 475 475 8.5 8.5 40 80 120 40 80 120 80 120 160 200 40 40 105 120 75 105 120 75 150 110 85 150 110 85 150 110 85 150 110 85 150 110 85 43 110 85 SERIES FILTERS UP TO 40 AMPS CAT B & A, 6kV @ 20 Amps. AS 1768, IEEE C62 compliant VOLTAGE Nominal (Vrms)/ Maximum (Vrms) MODELS FIG 6 FIG 7 FIG 8 PEAK DISCHARGE CURRENT With 8/20usec (kA) MAX “LET-THRU” VOLTAGE Volts/Modes INDICATION Visual/Remote W kA Industrial (Cat B) Integral 20Amp series filter Integral 20Amp series filter Integral 20Amp series filter + Relay Integral 20Amp series filter + Relay Integral 40Amp series filter Integral 40Amp series filter Series OR Parallel Cat B Up to 20 amps series connected unlimited in parallell connected TLP-GPO-10A TLP-SF20SL-120V (DIN style) TLP-SF20SL-240V (DIN style) TLP-SF20RI-120 TLP-SF20RI-240 TLP-SF40T-P120 TLP-SF40T-P240 TLP-SP20SL 30V TLP-SP20SL 50V TLP-SP20SL 150V TLP-SP20SL 275V 240/275 120 / 275 240 / 275 240 / 275 240 / 275 185 / 210 255/275 30 / 40 50 / 60 150 / 170 240 / 275 20 48 48 48 48 48 48 54 72 72 72 710 / 385 / 600 / 600 / 600 / 810 / 810 / 600 / 690 / 690 / 690 / 2 3 3 3 3 3 3 3 3 3 3 H N/N Y/N Y/N Y/Y Y/Y Y/N Y/N Y/ N Y/N Y/N Y/ N FIG 6 FIG 6 FIG 8 FIG 8 FIG 10 FIG 10 FIG 7 FIG 7 FIG 7 FIG 7 FIG 14 FIG 15 FIGURE No DIMENSIONS in mm D 1 x 10A GPO ith 2mtr lead 23 115 85 23 115 85 23 115 85 23 115 85 95 115 85 95 115 85 23 115 85 23 115 85 23 115 85 23 115 85 LOW VOLTAGE PROTECTORS, INSTRUMENTATION AND COMMUNICATIONS (Cat A & B) AS 1768, IEEE C62 compliant VOLTAGE Nominal (Vrms) Maximum (Vrms) MODELS FIG 11 FIG 12 FIG 13 PEAK DISCHARGE CURRENT With 8/20usec (kA) MAX “LET-THRU” VOLTAGE Volts/Modes INDICATION Visual/Remote W H D 17.5 75 65.5 6.2 90 100 6.2 90 100 6.2 90 100 6.2 90 kA Signals (either Analog or Digital) transmitters or switches * Other voltages upon request Protects 24v loop M20 entry Protects 24v loop NPT entry Protects 24v supply as well as loop M20 entry Protects 230v supply as well as loop M20 entry Bus Protectors * Other types upon request Coaxial RF Protectors * Other types upon request TLP-15L TO TLP-60L TLP-SL62-xxD (2 ch 6.2mm wide) TLP-SL62-xxD (2 ch 6.2mm wide) TLP-SL62-xxD (2 ch 6.2mm wide) TLP-SL62-xxD (2 ch 6.2mm wide) TLP-48HM/M20 TLP-48HM/NPT TLP-48HM-4W/M24 TLP-48HM-4W/M240 TLP-RS232 TLP-RS485 TLP-RS485/MB TLP-RS485/PB TLP-DNET TLP-48/RJ45H-4 TLP-N/FF TLP-F/MF TLP-F/FF 15 / 15 / 16 / 17 / 18 / 18 - 60 / 70 18 - 60 / 70 18 - 60 / 70 18 - 60 / 70 18 - 60 / 70 24 / 48 24 / 48 24 / 48 240/24/48 ±15 / ±18 ±12 / ±15 Vdc ±12 / ±15 Vdc ±12 / ±15 Vdc 24 / 31 24 / 31 70V 90V 90V 8 8 8 8 8 10 10 10 10 400W PPPD 400W PPPD 400W PPPD 400W PPPD 400W PPPD 400W PPPD 20 20 20 18 / 3 21 / 3 43 / 3 75 / 3 90 / 3 28 / 3 28 / 3 28 / 3 28 / 3 19 / 2 19 / 2 19 / 2 19 / 2 19 / 2 19 / 2 700 / 1kV/Ms 700 / 1Kv/Ms 701 / 1Kv/Ms Notes and Standards: AS 1768-2005, IEC61643-1, BS 6651-1992, IEEE C62. 41-1991, BS 2914-1972 N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N N N N N N N N N N N N N N N N N N Compliance: Perth - Melbourne - Sydney - Brisbane - Adelaide TransTech Electronic Controls Pty Ltd Perth H.O Design/Manufacturing Contact: Dale Tunbridge or John King MOB: or 0419-502-660 or or john@transtech.com.au 0439 911-883 or Mark Van Schalm (Melbourne) 0409 697-156 Unit 2 / 48 Dellamarta Road WANGARA W.A. 6065 dale@transtech.com.au \\server\i\Shared\Price Lists & data sheets\Transtech\Flyers\TLP_Listing.xlsx or mark@transtech.com.au FIG 14 FIG 13 FIG 13 FIG 13 FIG 13 FIG 15 FIG 15 FIG 15 FIG 15 FIG 14 FIG 14 FIG 14 .FIG 14 FIG 14 FIG 12 FIG 11 FIG 11 FIG 11 N2909 100 - 172 25 hex - 172 25 hex - 172 25 hex - 172 25 hex 17.5 75 65.5 17.5 75 65.5 17.5 75 17.5 75 65.5 30 75 65.5 85 55 25 65.5 TNC FEM/FEM Bulkhead F FEM/MALE F FEM/FEM Transient Protection Presentation 5. Transient Standards Categories and Definitions. According to AS 1768:2005 the installation of transient over-voltage protectors can be broken down into five (5) categories. Such categories are shown below from highest risk (E) to lowest risk (A): CAT E 6kV / 70kA The Point of entry to “very exposed or critically important site. Example: Telecom tower on hill. CAT D 6kV / 30kA CAT E – very high risk The point of entry to an exposed rural site. Example: Pump station a Country Area CAT C 6kV / 15 - 20kA The point of entry to a site in the City or built up area. Example: Most common building or site CAT B 6kV / 3kA Within a building immediately after the point of entry or Main Board. Example: Sub-boards. C CAT A B B 6kV / 500Amp Within a building and fed from a sub-board being CAT B location. Example: GPO,s C B A A - 10 – I:\Shared\Price Lists & data sheets\Transtech\Application Notes\TLP Presentation_new.docx TRANSTECH DATA SHEET Subject to change without notice MODEL :- TLP-80-1P Transtech Lightning Protector - 240V Single Phase, 3 Modes For CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 220VAC rms 275VAC rms 40 - 60Hz less than 800V Imax Response time Relay Contacts Surge Reset 80kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES 80(W) x 80(H) x 115(L) Relay Output Phase loss or Neutral Disconnected the relay de-energizes. Power On / Unit Healthy, (LED ON = healthy) LED’s (2) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max GENERAL DESCRIPTION The TLP-80-1P is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP-80-1P is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. 2 Plug in 2.5mm Red LED’s Mild Steel(Powder coated) 80 (H) x 80 (H) x 115 (L) 850 grams DIN 43880 Standard DIN Rail The TLP-80-1P offers a DIN style housing to suit most MCB profiles. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xx 1P. FEATURES REMOTE RELAY OUT Model No TLP-80-1P TRANSTECH UNIT HEALTHY 3 2 1 Remote Alarm 1 = N/O | 2 = COMM | 3 = N/C POWER ON SINGLE PHASE TRANSIENT PROTECTOR (Replace if OFF) L1 CAT C V = 240V In = 40kA Imax = 120kA N E SUPPLY L1 LOAD N E CONNECTION ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Neutral to Earth Monitor Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-80-1P new.docx 05/02/2011 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-120-1P Transtech Lightning Protector - 240V Single Phase, 3 Modes For CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 220VAC rms 275VAC rms 40 - 60Hz less than 800V Imax Response time Relay Contacts Surge Reset 120kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or Neutral Disconnected the relay de-energizes. Power On / Unit Healthy, (LED ON = healthy) LED’s (2) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 80(W) x 80(H) x 115(L) GENERAL DESCRIPTION The TLP-120-1P is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP-120-1P is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. 2 Plug in 2.5mm Red LED’s Mild Steel(Powder coated) 80 (H) x 80 (H) x 115 (L) 850 grams DIN 43880 Standard DIN Rail The TLP-120-1P offers a DIN style housing to suit most MCB profiles. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP 1P. FEATURES REMOTE RELAY OUT Model No TRANSTECH TLP-120-1P UNIT HEALTHY 3 2 1 Remote Alarm 1 = N/O | 2 = COMM | 3 = N/C POWER ON SINGLE PHASE TRANSIENT PROTECTOR (Replace if OFF) L1 CAT C V = 240V In = 40kA Imax = 120kA N E SUPPLY L1 LOAD N E CONNECTION ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Neutral to Earth Monitor Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed motherboard CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-120-1P new.docx 05/02/2011 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-P80-3DRI Transtech Lightning Protector - 415V Three Phase, 3 Mode For CAT C TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz Less than 810V In Imax Response time Relay Contacts Surge Reset 36kA 80kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss disconnected the relay de-energizes. L1, L2, L3, (LED ON = healthy) (LED AMBR = replace) LED’s (dual colour) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max GENERAL DESCRIPTION The TLP-P80-3DRI is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP-P80-3DRI is a true 3 mode (L-L / L-N / N-E) parallel connected surge protection device offering protection for all 3 phases, it also introduces a unique feature, by being connected to a TLP-DSI which will indicate the status of each phase remotely. 2 Plug in 2.5mm Red / Amber LED’s Mild Steel(Powder coated) 105 (W) x 120 (H) x 75 (D) 700 grams DIN 43880 Standard DIN Rail RELAY OUT LE D’s L1 -L2-L3 RED = OK AMBE R = DECRE ASE D OFF = REP LACE TLP TLP-P80-3DRI 3PH + E SURGE PROTECTION L1 L1 L1 N E LOAD SIDE SUPPLY SIDE FUSE/MCB PROTECT ION L1 For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xx-3P. FEATURES REMOTE IND OUT TRANSTECH The TLP-P80-3DRI is powered by all 3 phases and does not lose indication until all 3 phases have failed. This is a distinct advantage over units where indicators are powered from a single phase. L1 L2 L2 L3 L3 N N ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Internally protected – automatic reset Local status indication by dual colour LED’s Remote panel indicator Alarm status indication via in-built c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 E E CONNECTION DIAGRAM NOTE: This device must be installed by a Qualified Electrician DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-P80-3DRI new.docx 30 Jan 2010 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-80-3P/NEM Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral to Earth Monitoring For CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz Less than 810V Imax Response time Relay Contacts Surge Reset 80kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or Neutral & Earth both disconnected the relay de-energizes. L1, L2, L3, N-E (LED ON = healthy) LED’s (4) GENERAL DESCRIPTION The TLP-80-3P/NEM is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting 155(W) x 105(D) x 85(H) The TLP-80-3P/NEM is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 2 Plug in 2.5mm Red LED’s Mild Steel(Powder coated) 155 (W ) x 105(D) x 85 (H) 850 grams DIN 43880 Standard DIN Rail The TLP-80-3P/NEM now offers a Neutral to Earth protection monitoring circuit (NEMON) which until now has not been available. The NEMON circuit ensures that all 3 modes of protection are active and offers a fully monitored and reliable protection device. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xx-3P/NEM. REMOTE RELAY OUT RELAY OUT 1 = N/O 2 = COMM 3 = N/C FEATURES 1 2 3 TLP-80-3P/NEM THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR L1 L2 L3 NE SUPPLY L1 L2 L3 N E LOAD CONNECTION ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Neutral to Earth Monitor Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-80-3P_NEM new.docx 30 Jan 2010 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-P130-3DRI Transtech Lightning Protector - 415V Three Phase, 3 Mode For CAT C TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz Less than 810V In Imax Response time Relay Contacts Surge Reset 43kA (10 Impulses) 130kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss disconnected the relay de-energizes. L1, L2, L3, (LED RED = healthy) (LED AMBER = replace) LED’s (dual colour) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max GENERAL DESCRIPTION The TLP-P130-3DRI is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP-P130-3DRI is a true 3 mode (L-L / L-N / N-E) parallel connected surge protection device offering protection for all 3 phases, it also introduces a unique feature, by being connected to a TLP-DSI which will indicate the status of each phase remotely. 2 Plug in 2.5mm Red / Amber LED’s Mild Steel(Powder coated) 105 (W) x 120 (H) x 75 (D) 700 grams DIN 43880 Standard DIN Rail REMOTE IND OUT LE D’s L1 -L2-L3 RED = OK AMBE R = DECRE ASE D OFF = REP LACE TLP TLP-P130-3DRI 3PH + E SURGE PROTECTION L1 L1 L1 N E LOAD SIDE SUPPLY SIDE FUSE/MCB PROTECT ION L1 L1 L2 L2 L3 L3 N N E E For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xx-3P. FEATURES RELAY OUT TRANSTECH The TLP-P130-3DRI is powered by all 3 phases and does not lose indication until all 3 phases have failed. This is a distinct advantage over units where indicators are powered from a single phase. ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Internally protected – automatic reset Local status indication by dual colour LED’s Remote panel indicator Alarm status indication via in-built c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 CONNECTION DIAGRAM NOTE: This device must be installed by a Qualified Electrician DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-P130-3DRI new.docx 24 April 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-120-3P/NEM Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral Earth Monitoring CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz less than 810V Imax Response time Relay Contacts Surge Reset 120kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or Neutral & Earth both disconnected the relay de-energizes. L1, L2, L3, N-E (LED ON = healthy) LED’s (4) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting 155(W) x 105(D) x 85(H) GENERAL DESCRIPTION The TLP 120-3P/NEM is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP120-3P/NEM is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 2 Plug in 2.5mm Red LED’s Mild Steel (Powder coated) 155 (W) x 105 (D) x 85 (H) 850 grams DIN 43880 Standard DIN Rail The TLP-120-3P/NEM now offers a Neutral to Earth protection monitoring circuit (NEMON) which until now has not been available. The NEMON circuit ensures that all 3 modes of protection are active and offers a fully monitored and reliable protection device. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP 3P/NEM. FEATURES REMOTE RELAY OUT RELAY OUT 1 = N/O 2 = COMM 3 = N/C 1 2 3 TLP-120-3P/NEM THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR L1 L2 L3 NE SUPPLY L1 L2 L3 N E LOAD ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Neutral to Earth Monitor Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician. CONNECTION (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-120-3P_NEM new.docx 12 January 2010 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-160-3P Transtech Lightning Protector - 415V Three Phase, 3 Mode CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz less than 810V Imax Response time Relay Contacts Surge Reset 160kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or MOV failed the relay de-energizes. L1, L2, L3, N-E (LED ON = healthy) LED’s (4) GENERAL DESCRIPTION The TLP 160-3P is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting The TLP160-3P is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 2 Plug in 2.5mm Red LED’s Mild Steel (Powder coated) 155 (W) x 105 (H) x 85 (D) 850 grams DIN 43880 Standard DIN Rail 3 2 1 TLP-120-3P THREE PHASE TRANSIENT PROTECTOR L1 L2 L3 NE SUPPLY L1 L2 L3 N E FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ REMOTE RELAY OUT RELAY OUT 1 = N/O 2 = COMM 3 = N/C For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P LOAD Low “let thru” voltage Designed and manufactured to ISO 9001 Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician. CONNECTION (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-160-3P new.docx 27 June 2011 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-160-3P/NEM Transtech Lightning Protector - 415V Three Phase, 3 Mode with Neutral Earth Monitoring CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz less than 810V Imax Response time Relay Contacts Surge Reset 160kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or Neutral & Earth both disconnected the relay de-energizes. L1, L2, L3, N-E (LED ON = healthy) LED’s (4) GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting 155(W) x 105(D) x 85(H) GENERAL DESCRIPTION The TLP 160-3P/NEM is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The TLP160-3P/NEM is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 2 Plug in 2.5mm Red LED’s Mild Steel (Powder coated) 155 (W) x 105 (D) x 85 (H) 850 grams DIN 43880 Standard DIN Rail The TLP-160-3P/NEM now offers a Neutral to Earth protection monitoring circuit (NEMON) which until now has not been available. The NEMON circuit ensures that all 3 modes of protection are active and offers a fully monitored and reliable protection device. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP 3P/NEM. FEATURES REMOTE RELAY OUT RELAY OUT 1 = N/O 2 = COMM 3 = N/C 1 2 3 TLP-160-3P/NEM THREE PHASE TRANSIENT PROTECTOR WITH NEUTRAL/EARTH MONITOR L1 L2 L3 NE SUPPLY L1 L2 L3 N E LOAD ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Neutral to Earth Monitor Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2003 NOTE: This device must be installed by a Qualified Electrician. CONNECTION (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-160-3P_NEM new.docx 12 January 2010 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-240-3P Transtech Lightning Protector - 415V Three Phase, 3 Mode CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz less than 810V Imax Response time Relay Contacts Surge Reset 240kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output Phase loss or MOV failed the relay de-energizes. L1, L2, L3, (LED ON = healthy) LED’s (4) GENERAL DESCRIPTION The TLP 240-3P is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting The TLP 240-3P is a true 3 mode parallel connected protection device offering 3 levels of kA rating in all 3 modes. -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max 2 Plug in 2.5mm Red LED’s Mild Steel (Powder coated) 155 (W) x 105 (H) x 85 (D) 850 grams DIN 43880 Standard DIN Rail 3 2 1 TLP-240-3P THREE PHASE TRANSIENT PROTECTOR L1 L2 L3 NE SUPPLY L1 L2 L3 N E FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ REMOTE RELAY OUT RELAY OUT 1 = N/O 2 = COMM 3 = N/C For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P LOAD Low “let thru” voltage Designed and manufactured to ISO 9001 Internally protected – automatic reset Local status indication by LED’s Remote status indication c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 NOTE: This device must be installed by a Qualified Electrician. CONNECTION (CABLES 16sq/mm AS SHORT AS POSSIBLE) DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-240-3P new.docx 27 June 2011 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL: TLP-150-3M/CAT B Transtech Lightning Protector - 415V Three Phase, 3 Mode TECHNICAL DATA Normal working voltage Minimum working voltage Maximum working voltage Working Freq. Peak let thru volts Maximum mains current 415VAC rms 328VAC rms 476VAC rms 40 - 60Hz <800V Category In (Crest current) Imax (Max discharge current) Response time Surge Reset AS/NZS 1768 Cat B 60kA (8/20uS) 150kA (8/20uS) Less than 25nS Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES LED Indication LED’s ON = TLP healthy LED OFF = TLP repair Changeover volt-free Relay Output GENERAL SPECIFICATION FUSE/MCB PROTECTION Operating Temp Terminals Remote Terminals Indicators Housing Material Dimensions Weight Mounting -40 to +70 Deg C 2 2 16mm solid max / 10mm flex max N/A Green LED’s Aluminium (Powder coated) 95.5(W) x 72(H) x 108(L) 700 grams DIN 43880 Standard DIN Rail GENERAL DESCRIPTION The TLP-150-3M/CAT B is a lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. The mains borne transient voltages may occur as a result of lightning strikes or the switching of large inductive / capacitive loads. The TLP-150-3M/CAT B is a parallel device for Cat B applications and should be installed as close as possible to the supply being protected. It is recommended that connecting cables be kept shorter than 300mm. The TLP-150-3M/CAT B is a true 3 mode protection device with an Imax rating of 150kA for Cat B applications. For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP 150-3M. FEATURES TLP-XXX-3M/CATB ♦ ♦ ♦ ♦ ♦ ♦ 3PH 415V PROTECTION CAT B L1 L2 L3 N E LOAD SIDE SUPPLY L1 SIDE L2 L3 N E L1 L2 L3 N E ♦ ♦ ♦ ♦ Low “let thru” voltage Designed and manufactured to ISO 9001 Certified for BER Projects Internally protected – automatic reset LED status indication for power loss or fault Designed to pass IEC 616431-1:2005 and AS/NZS 1768:2003 Long lifetime, fully lacquered PCB’s CE Marking / C-tick N 2909 Full 3 mode protection DIN 43880 compliant CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:/Docs/word/DataSheets/TLP-150-3M/CATB th 14 October 2009 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET d Subject to change without notice MODEL TLP-DSI Direct Status Indicator TECHNICAL DATA The TLP-DSI is powered directly from the Remote Indicator (RI) output of Transtech TLP any High Energy TLP unit which incorporates the unique Remote Indicator circuitry. Status LEDs 3 x RED GENERAL SPECIFICATION Operating Temp. Connection Housing Material Dimensions Weight Mounting GENERAL DESCRIPTION The TLP-DSI is a self-powered remotely mounting status indicator which mirrors the status LEDs on Transtech’s High Energy TLP’s which have a unique remote Indicator (RI) output fitted. -25 to 70 degrees C 3 way 2.5mm2 plug-off ABS. 48 x 48 x 60 mm 25gm nominal Through panel mount The LEDs of the TLP-DSI match their respective status LED on the monitored TLP unit. A unique circuit design means that only 3 wires are required to display the status of any one of the monitored TLP LEDs. TRANST ECH The length of the 3 core cable between the TLP-xxx and its TLP-DSI should be no more than a maximum of 5 meters. TLP-DSI Max 5 mtr 3 core cable 0.5 sqmm REMOTE STATUS OUT REMOTE RELAY OUT FEATURES Model No TLP-40-3P TRANSTECH UNIT HEALTHY 3 2 1 Rem ote Alarm 1 = N/O | 2 = COMM | 3 = N/C ♦ ♦ ♦ ♦ ♦ ♦ ♦ POWER ON (Repl ace if OFF) THREE PHASE TRANSIENT PROTECTOR L1 L2 L3 CAT C V = 240V In = 40kA Im ax = 120kA N E LOAD L1 L2 L3 N E Designed and manufactured to ISO 9001 Small size 48mm x 48mm panel mount unit 3 bright, easy to read LEDs Status LEDs match those of the TLP LEDs Easy to connect - only 3 wires Plug-off terminals No setup required. CONNECTION DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE PAGE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-DSI.doc Confidential Page 1 March 12, 2013 DATA SHEET d Subject to change without notice MODEL TLP-PSI Powered Remote Status Indictaor TECHNICAL DATA Power Supply: VA Rating : 120, 220/240 +/- 15% Typically 1.3VA Status LEDs: Power Healthy Fault Output: BLUE RED YELLOW Relay volt free contact GENERAL SPECIFICATION Operating Temp. Power Terminals Sense Terminals Relay Output Term. Indicators Housing Material Dimensions Weight Mounting GENERAL DESCRIPTION -25 to +70 degrees C 2 Plug in 1.5mm 2 Plug in 1.5mm 2 Plug off 2.5mm Blue, Red, Yellow LEDs ABS 48 x 48 x 60 50gm nominal Through panel mount The TLP-PSI is a 48mm x 48mm AC powered, status indicator which may be connected to any TLP product which incorporates a status output relay. The TLP-PSI can be mounted in a convenient location at some distance from the associated transient protection device. The TLP-PSI uses a transformer isolated 24V DC to monitor the TLP status (fault) relay, it has three status LEDs; BLUE = Power OK RED = Healthy YELLOW = Faulty (replace) TRANST ECH TLP-PSI/240V Supply Neutral 120Vac or 240Vac Line REMOTE RELAY OUT REMOTE RELAY OUT FEATURES Model No TLP-40-3P TRANSTECH UNIT HEALTHY ♦ ♦ ♦ ♦ ♦ ♦ 3 2 1 Rem ote Alarm 1 = N/O | 2 = COMM | 3 = N/C POWER ON (Repl ace if OFF) THREE PHASE TRANSIENT PROTECTOR L1 L2 L3 SUPPLY L1 L2 L3 N E CAT C V = 240V In = 40kA Im ax = 120kA N E ♦ LOAD Designed and manufactured to ISO 9001 Small size 48mm x 48mm panel mount unit 3 bright, easy to read LEDs Easy to connect Plug-off terminals Boxed (shrouded) AC connector No setup required. DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE PAGE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-PSI.docx Confidential Page 1 March 7, 2013 DATA SHEET Subject to change without notice MODEL :-TLP-415P/E-DIN Transtech Lightning Protector (no Neutral) - CAT B TECHNICAL DATA Voltage rating Normal working voltage 415V Max. working volts 480V RMS Working Freq. 40 - 60 Hz Peak let thru volts 710V Protection Modes Phase -Earth ONLY Surge Rating 20kA, Mass Surge Material 60kA 8/20uSecs Meets Surge Ratings to AS/NZS 1768-1991 IEEE C 62.41, UL 1449 Earth Leakage Approx 500uA Operating Current N/A in parallel L x H x W = 112mm x 75mm x 45mm GENERAL SPECIFICATION GENERAL DESCRIPTION Operating Temp Storage Temp Humidity Indication Terminals The TLP-415P/E-DIN series is a lightning and power transient arrester which provide voltage surge limitation to power electrical devices connected to the mains power supply. The TLP-415P/E-DIN provides effective protection by clamping the over voltage to a safe level. Three (3) indicators show if the TLP-415P/E-DIN is “healthy” and providing protection. Should one(1) indicator go off replacement should be done as soon as possible if ALL three indicators are off the device must be replaced IMMEDIATELY. The TLP-415P/E-DIN must always be installed on the load side of a fuse or MCB. The TLP-415P/E-DIN can be mounted directly on to “G” or “DIN” rails (DIN 46277-1 and 46277-3) Housing Material Mounting Style Dimensions Weight -20 to 70 Deg C -55 to 75 Deg C 0 - 90% RH 3 Neon indicators Self opening 0.5 - 10mm 20 - 6 AWG KRILEN / AL cover DIN or G rail 112mm x 75mm x 45mm 195 grams L1 L2 L3 BENEFITS:- EARTH ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between 3 Phases – Earth Fast snap on DIN rail mounting 26kA discharge capacity per line Location Category B to AS 1768 CE / C-tick marking ♦ Ensure that the Earth is appropriately terminated at all times. Ensure that the all Phases are at 0V potential before removing the unit for service. *** CAUTION *** DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-415p e.din new.docx Confidential August 24, 2011 20 AMP Series Filter 23mm WIDE Model: TLP-SF20-SL-240V Model: TLP-SP20-SL-240V www.transtech.com.au TRANSTECH ELECTRONIC CONTROLS Electronic Transient Surge Protection UNIQUE FEATURES: Slimmest 20Amp Model available 3rd Party Tested to IEC 61643-1:2005 (PASSED) High Fault Rating 54kA Mass Metal Hosuing Front LED Australian Designed and Manufactured Over 15,000 Installed Australia Wide Transtech Electronic Controls Pty Ltd ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: (03) 9330-3624 Info@transtech.com.au Also in Melbourne - Sydney – Brisbane – Adelaide TRANSTECH DATA SHEET d Subject to change without notice MODEL :-TLP-SF20SL-240V Transtech Lightning Protector/Surge Filter - 20Amp for 240Vac TECHNICAL DATA Voltage rating Normal working voltage 240V RMS 275V RMS 40 - 60 Hz 710 V (typical 1 pulse) Ph-N, Ph-E, N-E Max. Working volts Working Freq. Peak let thru volts Protection Modes Surge Rating;Imax (max discharge current)42kA (8/20msec) @ 75% 24kA Iin (crest current) Meets Surge Ratings to AS/NZS 1768:2003 IEEE C 62.41, UL 1449 Tested & Pass to IEC 61643.1:2005 Surge Filter Inductor Type Common Mode 20A choke Capacitors X and Y Cut-off Frequency Less than 1kHz (-3dB loss) Attenuation (60dB) 5MHz Earth Leakage Approx. 500uA Operating Current 3mA nominal Loss Less than 2Watts Continuous Current 20 Amps L x H x W = 112mm x 75mm x 23.5mm nom. GENERAL DESCRIPTION The TLP-SF20SL series are lightning and power surge transient arrestors with surge filtering. These provide voltage limitation and filtering of transients for sensitive electronic devices connected to the mains power supply. The TLP-SF20SL provides effective protection via a three stage circuit. The input stage limits the over-voltage excursion, the second stage series surge filter restricts the rate of rise of voltage (dV/dt) of any transient over-voltage and the final stage clamps the output voltage to a safe level. The TLP-SF20SL must always be installed on the load side of a fuse rated at 20 amps or less. The TLP-SF20SL can be mounted directly on to “G” or “DIN” rails (DIN 46277-1 and 46277-3) GENERAL SPECIFICATION Operating Temp Storage Temp Humidity Terminals -35 to 70 Deg C -55 to 90 Deg C 0 - 90% RH Self opening 0.5 – 4sq mm Housing Material Mounting Style Dimensions (LxHxW) nom. Weight MS cover/ ABS base DIN or G rail 112mm x 75mm x 23.5mm 175 grams INPUT POWER UNIT HEALTHY LED BENEFITS:♦ ♦ ♦ LINE CB / FUSE L N E ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ SYSTEM HEALTHY RCD DEVICE TLP-SF20SL TLP-SF L N E LOAD OUTPUT POWER CLEAN Slim 23mm wide metal housing. Low “let thru” voltage Series inductor to control rate of voltage rise Protection between all lines System Healthy Indicator - LED Fast snap on DIN rail mounting 24kA discharge capacity per line For location Cat B to AS 1768:2003 Tested & Passed to IEC 61643-1:2005 Designed to IEEE C 62.41 (UL1449) Designed and manufactured in Australia to ISO 9001 DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE PAGE Page 1 of 2 ISSUE A / Rev C I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SF20SL-240V revc.docx Confidential Page 1 November 2, 2011 DATA SHEET Subject to change without notice MODEL :-TLP-SF20RI-240V Transtech Lightning Protector/Filter - 20Amp for 240Vac with Relay TECHNICAL DATA Voltage rating Max. working volts Working Freq. Peak let thru volts Protection Modes Surge Rating: Imass Imax Iin Operating Burden Meets Surge Ratings to Filter Inductor Type Capacitors Attenuation Earth Leakage Operating Current Maximum Current Normal working voltage 220 - 250V RMS 275V RMS 40 - 60 Hz 710V (single pulse) Ph-N, Ph-E, N-E 108kA 72kA 48kA Approx 7mA AS/NZS 1768:2003 IEEE C 62.41:2005UL 1449 Common Mode 20A choke X and Y (60dB) 5MHz Approx 500uA 20 Amps 22 Amps GENERAL DESCRIPTION The TLP-SF20RI series is a series of lightning and power transient arrestors with filtering + LED and relay output which provides voltage surge limitation and filtering to sensitive electronic devices connected to the mains power supply and rated up to 20 amps. Other Features Relay Output Form C 5A continuous (Relay fails to safe position) Plug-in 0.5 – 2.5mm Relay Terminals The TLP-SF20RI provides effective protection by clamping the over voltage and via the series filter reducing the rate of rise of the clamped voltage to a safe level. If a fault occurs within the TLP-SF20RI the “healthy LED will extinguish and the relay will de-energize). GENERAL SPECIFICATION Operating Temp Storage Temp Humidity Terminals Housing Material Mounting Style Dimensions (HxWxD) Weight -35 to 70 Deg C -55 to 75 Deg C 0 - 90% RH Self opening 0.5 – 4 sq mm Mild Steel – DIN clip feet DIN rail 120mm x 52mm x 80mm 195 grams INPUT SUPPLY L N E The TLP-SF20RI must always be installed on the load side of a protective device rated at 20 amps or less. The TLP-SF20RI can be mounted directly on to “DIN” rails (DIN 46277-1) BENEFITS:- ALARM OUTPUT INPUT ♦ ♦ ♦ N/O COM N/C ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ RELAY Power TLP-SF20RI-240 SERIES FILTER SURGE PROTECTOR Fault OUTPUT TRANSTECH L N E OUTPUT CLEAN SUPPLY Low “let thru” voltage Series filter to control rate of voltage rise Protection between all lines (diff & common mode) Power “ON” indication Unit “HEALTHY” indication (with relay) Fast snap on DIN rail mounting Designed for MEN Systems Location Category B to AS 1768:2005 Tested to IEEE C 62.41:2005 & compliant) Designed and manufactured to ISO 9001 CE / C-tick marking DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE PAGE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SF20RI-240.doc Confidential Page 1 8/9/2012 DATA SHEET MODEL :-TLP-SP20SL-275 Transtech SERIES/PARALLEL Lightning Protector - 20Amp for 275V TECHNICAL DATA Voltage rating Normal working voltage 240V DC/AC 275V DC/AC DC - 60 Hz Max. Working volts Working Freq. Rated Current 20 Amps for series connect Unlimited for parallel connect Peak let thru volts Protection Modes Surge Rating;- 900 V Ph-N, Ph-E, N-E Ph-N, 24kA, 8/20μS Ph-E, 24kA, 8/20μS N-E, 24kA, 8/20μS 72kA Approx 500uA 20 Amps Imax Earth Leakage Continuous Current (see above re series/parallel) GENERAL DESCRIPTION Meets Surge Ratings to AS/NZS 1768:2003 IEEE C 62.41, UL 1449 IEC 61643.1:2005 GENERAL SPECIFICATION Operating Temp Storage Temp Humidity Terminals -35 to 70 Deg C -55 to 90 Deg C 0 - 90% RH Self opening 0.5 – 4sq mm Housing Material Mounting Style Dimensions (LxHxW) Weight M/Steel cover / ABS base DIN or G Rail 112mm x 75mm x 23.5mm 175 grams SERIES INPUT POWER UNIT HEALTHY LED The TLP-SP20SL can be mounted directly on to “G” or “DIN” rails (DIN 46277-1 and 46277-3) BENEFITS:OUTPUT TO LOAD UNLIMITED amps FUSES Max 20amps L N E UNIT HEALTHY LED SYSTEM HEALTHY L N E SYSTEM HEALTHY L N E The TLP-SP20SL must always be installed on the load side of a fuse rated at 20 amps or less. PARALLEL INPUT POWER FUSES Max 20amps TLP-SP20SL The TLP-SP20SL range is either a series or parallel connected lightning and power transient arrestor. The range provides voltage surge limitation for sensitive electronic devices connected to the mains power supply. TLP-SP20SL L N E OUTPUT TO LOAD MAX 20amps ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Slim 23mm wide metal housing. Low “let thru” voltage Protection between all lines System Healthy Indicator Fast snap on DIN rail mounting 24kA discharge capacity per line For location Cat B to AS 1768:2003 Tested to IEC 61643-1:2005 Tested to IEEE C 62.41 (UL1449) Designed and manufactured in Australia to ISO 9001 CONNECTION SCHEDULE DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. PAGE 1 / 1 ISSUE A REV B www.transtech.com.au TRANSTECH ELECTRONIC CONTROLS Low Cost Surge Protection Transtech Electronic Controls Pty Ltd ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: (03) 9330-3624 Info@transtech.com.au Also in Melbourne - Sydney – Brisbane – Adelaide TRANSTECH DATA SHEET Subject to change without notice MODEL :- TLP-V60/275/S Transtech Lightning Protector - 240V Plug-in Protectors CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 185VAC rms 275AC rms 40 - 60Hz less than 1000V Imax Response time Relay Contacts Surge Reset 60kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output MOV failed the relay de-energizes. L1, L2, L3, flag type Indicator GENERAL DESCRIPTION The TLP-V60/275S is a “new series” PLUG-IN lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting -40 to +80 Deg C 2 The TLP-V60/275S is a single mode parallel connected protection device offering 60kA single mode but for all three phases. see “1 Pole N/E” version Fig below. 2 35mm solid max / 10mm flex max 2 Plug in 2.5mm Green/Red mechanical flag Thermoplastic UL94-V-O IP-20 18 (W) x 60 (H) x 90 (D) 850 grams DIN 43880 Standard DIN Rail For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ LOAD SIDE SUPPLY SIDE L1 L2 L3 FUSE/MCB PROTECTION L1 L2 L3 L TRANSTECH TLP-V60 N/PE L N L TRANSTECH TRANSTECH TRANSTECH L L TRANSTECH TRANSTECH TLP-V60 TLP-V60 TLP-V60 TLP-V60 TLP-V60 PE PE NOTE: This device must be installed by a Qualified Electrician. N E N E 1 Pole N/E 1 Pole N+E Designed and manufactured to ISO 9001 Local status indication by mechanical flag Remote status indication by c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Available in 1P or 2P or 3P bases DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 3 Pole + E CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275s.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-V60/275/SM Transtech Lightning Protector - 240V Plug-in Protector Range CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 185VAC rms 275AC rms 40 - 60Hz less than 1000V Imax Response time Relay Contacts Surge Reset 60kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output MOV failed the relay de-energizes. L1, L2, L3, flag type Indicator GENERAL DESCRIPTION The TLP-Vxx/275/S is a “new series” PLUG-IN lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting -40 to +80 Deg C 2 The TLP-V60/275SM is the replacement plug-in module single mode parallel connected 60kA protection device. 2 35mm solid max / 10mm flex max 2 Plug in 2.5mm Green/Red mechanical flag Thermoplastic UL94-V-O IP-20 18 (W) x 60 (H) x 90 (D) 850 grams DIN 43880 Standard DIN Rail For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ LOAD SIDE SUPPLY SIDE L1 L2 L3 FUSE/MCB PROTECTION L1 L2 L3 L TRANSTECH TLP-V60 N/PE L N L TRANSTECH TRANSTECH TRANSTECH L L TRANSTECH Designed and manufactured to ISO 9001 Local status indication by mechanical flag Remote status indication by c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Available in 1P or 2P or 3P bases DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 TRANSTECH TLP-V60 TLP-V60 TLP-V60 TLP-V60 TLP-V60 PE PE NOTE: This device must be installed by a Qualified Electrician. N E N E 1 Pole N/E 1 Pole N+E 3 Pole + E CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275sm.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-DS60/275-2V Transtech Lightning Protector - 240V 1P+N E Protector 60kA CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 185VAC rms 275AC rms 40 - 60Hz less than 1000V Imax Response time Relay Contacts Surge Reset 100kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output MOV failed the relay de-energizes. Flag type Indicator GENERAL DESCRIPTION The TLP-V60/275S is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to a single phase distribution system. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting The TLP-V60/275S is a single mode parallel connected protection device offering 60kA single mode L-N and L-E(PE) (see middle Fig bottom left). -40 to +80 Deg C 2 2 35mm solid max / 10mm flex max Plug in 2.5mm2 Green/Red mechanical flag Thermoplastic UL94-V-O IP-20 36 (W) x 60 (H) x 90 (D) 850 grams DIN 43880 Standard DIN Rail For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P FEATURES LOAD SIDE SUPPLY SIDE ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ L1 L2 L3 FUSE/MCB PROTECTION L1 L2 L3 L TRANSTECH TLP-V60 N/PE L N TRANSTECH TRANSTECH L TRANSTECH L L TRANSTECH TRANSTECH TLP-V60 TLP-V60 TLP-V60 TLP-V60 TLP-V60 PE PE NOTE: This device must be installed by a Qualified Electrician. N E N E 1 Pole N/E 1 Pole N+E Designed and manufactured to ISO 9001 Local status indication by mechanical flag Remote status indication by c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Available in 1P or 2P or 3P DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 3 Pole + E CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-ds60-275-2vs.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-V100/275 Transtech Lightning Protector - 240V 1P Protector 100kA CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms 185VAC rms 275AC rms 40 - 60Hz less than 1000V Imax Response time Relay Contacts Surge Reset 100kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output MOV failed the relay de-energizes. L1, L2, L3, flag type Indicator GENERAL DESCRIPTION The TLP-V100/275S is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting The TLP-V100/275S is a single mode parallel connected protection device offering 60kA single mode. -40 to +80 Deg C 2 2 35mm solid max / 10mm flex max 2 Plug in 2.5mm Green/Red mechanical flag Thermoplastic UL94-V-O IP-20 36 (W) x 60 (H) x 90 (D) 850 grams DIN 43880 Standard DIN Rail For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ LOAD SIDE SUPPLY SIDE L1 L2 L3 FUSE/MCB PROTECTION L1 L2 L3 L TRANSTECH L TRANSTECH TLP-V100 TLP-V100 NOTE: This device must be installed by a Qualified Electrician. N E N E Designed and manufactured to ISO 9001 Local status indication by mechanical flag Remote status indication by c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Available in 1P or 2P or 3P DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 1 Pole N+E CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v100-275.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-DS60/275/3V Transtech Lightning Protector – 3 x 240V Plug-in Protectors CAT C or less TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current 240VAC rms L – E(PE) 185VAC rms 275AC rms 40 - 60Hz less than 1000V Imax Response time Relay Contacts Surge Reset 60kA (8/20uS) Less than 25nS SPCO (1 amp @240Vac) Automatic Unlimited (parallel connected) Must be fuse protected over 100A Mains SPECIAL FEATURES Relay Output MOV failed the relay de-energizes. L1, L2, L3, flag type Indicator GENERAL DESCRIPTION The TLP-DS60/275 3V is a “new series” lightning and transient protector which provides protection for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting -40 to +80 Deg C 2 The TLP-DS60/275 3V is a single mode parallel connected protection device offering 60kA single mode for Line 1,2,3 and Earth – see “3 Pole PE” version Fig below. 2 35mm solid max / 10mm flex max 2 Plug in 2.5mm Green/Red mechanical flag Thermoplastic UL94-V-O IP-20 55 (W) x 60 (H) x 90 (D) 850 grams DIN 43880 Standard DIN Rail For mains supply of greater than 100A adequate HRC fuse or MCB protection must be installed prior to the TLP-xxx- 3P FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ LOAD SIDE SUPPLY SIDE L1 L2 L3 FUSE/MCB PROTECTION L1 L2 L3 L TRANSTECH TLP-V60 N/PE L N L TRANSTECH TRANSTECH TRANSTECH L L TRANSTECH TRANSTECH TLP-V60 TLP-V60 TLP-V60 TLP-V60 TLP-V60 PE PE NOTE: This device must be installed by a Qualified Electrician. N E N E 1 Pole N/E 1 Pole N+E Designed and manufactured to ISO 9001 Local status indication by mechanical flag Remote status indication by c/o relay High Energy designed pcb’s CE Marking / C-tick N 2909 Available in 1P or 2P or 3P bases DIN 43880 compliant Designed to pass IEC 61643-1:2005 and AS/NZS 1768:2005 3 Pole + E CONNECTION DIAGRAM DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-v60-275s.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-LEC-A Transtech Surge/ Lightning Counter TECHNICAL DATA Normal Working voltage Minimum Working voltage Maximum Working voltage Working Freq. Peak let thru volts Maximum mains current Imax Response time Relay Contacts Surge Reset 110 - 240VAC 275AC 40 - 60Hz 100A Automatic SPECIAL FEATURES Relay Output Indicator Battery 2 digit LCD 7.2V service life 1 year GENERAL DESCRIPTION The TLP-LEC-A is a “new series” lightning and transient protector COUNTER with sensor for electrical / electronic equipment connected to three phase distribution systems. GENERAL SPECIFICATION Operating Temp Terminals Remote Terminals Indicators Housing Material Degree Protection Dimensions (module) Weight Mounting -40 to +80 Deg C 2.5mm 2 Digit LCD Thermoplastic UL94-V-O IP-20 18 (W) x 60 (H) x 90 (D) 125 grams DIN 43880 Standard DIN Rail LOAD SIDE L1 L2 L3 N E FEATURES ♦ ♦ ♦ ♦ CONNECTION DIAGRAM SUPPLY SIDE The TLP-LEC-A has a single current sensor for monitoring any one phase – if three phases require monitoring ins tall 3 TLP-LEC-A units. Designed and manufactured to ISO 9001 CE Marking / C-tick N 2909 Available in 1P only DIN 43880 compliant L1 L2 L3 N E SUPPLY SENSOR L N TLP-LEC-A 99 TRANSTECH NOTE: This device must be installed by a Qualified Electrician. DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-lec-a.docx 01 Feb 2013 PAGE 1 / 1 ISSUE A / Rev A LOW VOLTAGE & BUS PROTECTORS – Cat B or A www.transtech.com.au TRANSTECH ELECTRONIC CONTROLS Electronic Transient Surge Protection NEW Transtech Electronic Controls Pty Ltd ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: (03) 9330-3624 Info@transtech.com.au Also in Melbourne - Sydney – Brisbane – Adelaide TRANSTECH DATA SHEET Subject to change without notice MODEL :- TLP-SL62-30D Transtech Lightning Protector - Dual Channel TECHNICAL DATA Voltage rating (per channel) Normal working volt 30V D.C. (peak AC) Max. working volts 37V D.C. (peak AC) Peak let thru volts 43.5V Current/Resistance rating (per channel) End to End resist. 6 ohms nominal Max Current 500 mA Discharge Current 2kA per mode or 4kA per line (8/20usec) Response rating Response time: Under 10nsec 93mm x 102.5mm x6.2mm GENERAL SPECIFICATION GENERAL DESCRIPTION Operating Temp Storage Temp Connections Housing Material Mounting Style Dimensions Weight The TLP-SL62 series of lightning and transient arrestors are manufactured in a slim-line 6.2mm housing for those applications where a high packing factor is required. The units provide protection for electronic equipment connected to twisted pair control and communication signal lines. -10 to 70 Deg C -40 to 105 Deg C Self-opening 2.5mm/12AWG Polyester PBT DIN Rail 93.1(d) x 102.5(h) x 6.2(w) 52 grams The TLP-SL62-30D has true three stage protection in all modes. FEATURES TLP-SL62-xxD 3 6 2 7 1 8 INPUT 1 CLEAN OUT 1 5 INPUT 2 4 CLEAN OUT 2 Transient Barrier CAT B Imax = 8kA Voltage (Uc) = ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Dual channel unit Two independent channels ( common earth) 3 stage protection Low “let thru” voltage Protection between ALL lines Designed for 3kV impulse protection Fast snap on DIN rail mounting Fail to safe Field proven technology 4kA discharge capacity per channel Designed and manufactured to ISO 9001 6.2mm Slim Profile 300mm uncommitted earthing cable CE marking / C-tick N2909 V N2909 Earth DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL62-30D new.doc Confidential August 23, 2011 DATA SHEET Subject to change without notice MODEL :- TLP-SL12-xx Transtech Lightning Protector for Low Voltages 05V – 48V TECHNICAL DATA Voltage rating Normal working volt Peak let thru volts 05,12,15,18,24,48V +/10,19,25,29,39,78V resp. Current/Resistance rating End to End resist. Less than 6 ohm Max Current 600 mA Surge Current Imax 2 kA/mode (8/20uS) Response rating Response time Under 10nsec GENERAL SPECIFICATION GENERAL SPECIFICATION Operating Temp Storage Temp Terminals Housing Material Mounting Style Dimensions Weight -10 to 60 Deg C -55 to 75 Deg C Self-opening 2.5mm/12AWG KRILEN DIN 110mm X 52mm X12mm 60 grams GENERAL DESCRIPTION The TLP-SL12-xx series is a very compact 12mm wide lightning and transient arrester providing protection for equipment connected to low voltage instrument loops by limiting the transient over-voltage to less than twice the normal working voltage. The TLP-SL12-xx series provides protection between all conductors, line to line and each line to earth. It is mounted on to “DIN” rail (46277-3) and offers screen termination via terminals and the earth via a 300 mm earth wire “tail”. CABLE INPUT 1 2 3 4 2 4 1 2 3 4 1 3 INPUT LINE TRANSTECH TRANSTECH TLP-SL12-xx INPUT LINE OUTPUT LINE OUTPUT LINE 5 7 FEATURES 2 4 TLP-SL12-xx SERIES CONNECTION 1 3 PARALLEL CONNECTION CABLE INPUT 6 8 5 7 6 8 5 6 5 6 7 8 7 8 CABLE OUTPUT ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between ALL lines Fast snap on DIN rail mounting Fail to safe status design Field proven technology Low line losses (volt drop) Designed and manufactured to ISO 9001 High stacking density C-Tick/ CE Compliant IEC 1000-4-2 & EN50082 CONNECTION SCHEDULE DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL12-xx.docx Confidential November 6, 2012 DATA SHEET Subject to change without notice MODEL :- TLP-48HM-4W-240 Transtech Lightning Protector - Process Transmitter Loop plus 240V Supply Protector TECHNICAL DATA Voltage Rating Current Loop: Supply: 22V – 48Vdc (black/black) 190-265Vac (blue/brown) Current/Impedance Rating End to End Impedance: N/A parallel connection Max Current: N/A parallel connection Discharge Power: Imax = 10kA (8-20uS wave) Response rating Response time: EMC Compliance: Field Bus: Less than 10nS EN50082 part 2 C-tick / CE compliant 31.25kbit/s 25mm Hex x 75mm c/- 250mm leads GENERAL SPECIFICATION Operating Temp: Storeage Temp: Humidity: Termination wires: (colour coding) Housing Material: Dielectric Strength: Thread: Weight: Dimensions: -20 to 60 Deg C -40 to 80 Deg C 5% to 95% RH (Non-condensing) Flying Leads (250mm 1.0mm2) Blue & Brown for 240vac supply Black for 4-20mA signal Green / Yellow for earth ANSI 316 Stainless Steel o 25 C, 50 kHz, 19kV/mm a) 20mm ISO (M20 x 1.5) b) ½” NPT 185g 75mm (L) x 25mm Hex c/- 250mm coloured leads GENERAL DESCRIPTION The TLP-48HM-4W-240 lightning/transient protector provides protection for field mounted transmitters or electronic devices mounted in exposed areas. The TLP-48HM-4W-240 consists of a high speed solid state switching network which protects all signal and supply lines and common earth. The front end protection per line has a gas discharge tube with a 10kA rating. The housing material is ANSI 316 stainless steel with a 23mm flat for assisting mechanical mounting. The unit is encapsulated in high temperature casting epoxy. This epoxy offers high impact resistance with excellent electrical properties and high temperature stability. The standard male thread is the common 20mm conduit entry (20mm ISO, M20 x 1.5), several other thread types are available upon request. The TLP-48HM-4W-240 is designed to be added to standard installations. Most field transmitters have two conduit entries, one is used to connect the data cable, the spare can be used for the TLP48HM-4W-240 connection. Under most field installations no additional connection boxes are required. Should no spare entry be available then a simple conduit tee can be used as close as possible to the field device. The TLP-48HM-4W-240 connection is a simple parallel connection for BOTH supply and signal lines (see connection schedule). Care must be taken in the earthing of the green/yellow earth wire from the TLP48HM-4W-240. This earth wire must be earthed to local general/structural metal work, all leads to be kept as short as possible at all times. FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ESD Protection Low “let thru” voltage Protection between ALL lines (including 240vac supply) Field proven technology Simple field mounting Field Buss compatible (4-20mA loop only) Parallel Connection (No loop impedance) Designed and manufactured to ISO 9001 C-Tick/CE compliant Meets AS/NZS 1768:2003 Class B Meets IEC 61643.1:2005 Class I & II Auto resetting High 10kA discharge DESIGNED & MANUFACTURED by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE. I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-48HM-4W-240rev.doc 1st January 2009 PAGE 1 / 1 ISSUE C / Rev A DATA SHEET Subject to change without notice MODEL :- TLP-SL12-RS 485MB Transtech Lightning Protector - RS-485 (Modbus Compatible) TECHNICAL DATA Voltage rating Normal working volt Peak let thru volts Peak let thru volts +/- 12V 19V @ 1p = 1A 24V @ 1p = 10A Current/Resistance rating End to End resist. Less than 0.6 ohms Max Current 1 Amp Discharge Power 400W PPPD @ (8/20uS) (Peak Pulse Power Discharge) Response rating Response time Under 10nsec GENERAL SPECIFICATION GENERAL SPECIFICATION Capacitance Operating Temp Storage Temp Terminals 2.5mm/12AWG Housing Material Mounting Style Dimensions Weight GENERAL DESCRIPTION The TLP-SL12-RS 485MB is a very compact 12mm wide lightning and transient arrester providing protection for equipment connected to the Modbus RS 485 multi-point or party line bus by limiting the transient over-voltage to less than twice the normal working voltage. @ 1mMz, 75pF -10 to 60 Deg C -55 to 75 Deg C Self-opening KRILEN DIN 110mm X 52mm X12mm 60 grams The TLP-SL12-RS 485MB provides protection between all conductors, line to line and each line to earth. It is mounted on to “DIN” rail (46277-3) and offers screen termination via terminals and the earth via a 300 mm earth wire “tail”. FEATURES RS-485 BUS L1 +ve Screen ♦ ♦ ♦ ♦ ♦ L2 -ve 1 3 2 4 2 4 1 3 2 4 INPUT LINE TRANSTECH TRANSTECH TRANSTECH TLP-SL12-RS485 1 3 2 4 INPUT LINE TRANSTECH TLP-SL12-RS485 INPUT LINE TLP-SL12-RS485 INPUT LINE TLP-SL12-RS485 1 3 CLEAN LINE CLEAN LINE CLEAN LINE CLEAN LINE 5 7 5 7 5 7 5 7 6 8 6 8 END OF LINE R 6 8 END OF LINE R 6 8 30 NODES RS 485 STN RS 485 STN RS 485 STN ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between ALL lines Fast snap on DIN rail mounting Fail to safe status design High speed switch technology to prevent signal attenuation Low line losses (volt drop) Designed and manufactured to ISO 9001 C-Tick/ CE Compliant IEC 1000-4-2 & EN50082 RS 485 STN CONNECTION SCHEDULE DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-SL12-RS485MB.docx Confidential November 6, 2012 DATA SHEET Subject to change without notice MODEL :- TLP-DNET Transtech Lightning Protector - DeviceNet TECHNICAL DATA Voltage Rating Supply Normal Working voltage Max. Working voltage Varistors voltage Surge current 24V D.C. 31V D.C. 39V D.C. 1000A@(8/20uS) Current/Resistance Rating End to End resist. Less than 0.2R Max Current Thin cable = 4Amp Thick cable = 8 Amp Discharge Power 300W PPPD@ (8/20uS (dissipation per line) Protection Protection modes CAN-H to CAN-L, CAN-H to Screen CAN-L to Screen, Screen to V-Screen to V+, V+ to VLine Capacitance 15pF Breakdown Voltage 26.7V D.C. minimum Clamp voltage 43.0V D.C. maximum @ (8/20uS) GENERAL SPECIFICATION Operating Temp Storeage Temp Terminals 2.5mm/12AWG Housing Material Mounting Style Dimensions Weight 1 2 3 4 5 V1 L S H V+ BUS CONNECTION 1 2 3 4 5 V1 L S H V+ BUS CONNECTION The TLP-DNET provides very effective protection by limiting the transient overvoltage to less than twice the normal voltage on the supply and data lines. KRILEN DIN 75mm X 45mm X 30mm 120 grams The TLP-DNET provides protection between all conductors, Power/data line to line and line to earth. X V1 1 H 4 V+ 5 L 2 S 3 1 2 3 4 5 V1 L S H V+ BUS CONNECTION TRANSTECH X TLP-DNET SUPPLY/CONTROLLER S 3 1 2 3 4 5 V1 L S H V+ BUS CONNECTION X TLP-DNET H 4 V+ 5 CLEAN LINES The TLP-DNET can be mounted on DIN rail and the earth return in via a 5mm earth stud. FEATURES TRANSTECH V1 1 L 2 BUS INPUT TRANSTECH SUPPLY/CONTROLLER The TLP-DNET lightning and transient arrestor provides protection for equipment connected to the DEVICENET INTERFACE NETWORK. -10 to 70 Deg C -55 to 80 Deg C Self opening CAN bus TRANSTECH GENERAL DESCRIPTION X TLP-DNET TLP-DNET SUPPLY/CONTROLLER SUPPLY/CONTROLLER V1 1 V1 1 L 2 S 3 H 4 V+ 5 L 2 S 3 H 4 V+ 5 NODES PSU NODE PSU NODE PSU NODE PSU NODE DeviceNET STN DeviceNET STN DeviceNET STN DeviceNET STN CONNECTION SCHEDULE ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ESD Protection > 25kV Low “let thru” voltage Protection between ALL lines Fast snap on DIN mounting Fail to safe status design IEC 1000-4-2 & EN50082 Ultra low capacitance data line Field proven technology Low line losses (volt drop) Designed and manufactured to ISO 9001 High stacking density C-Tick / CE Compliant DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-DNET new.docx Confidential August 25, 2011 COMMUNICATIONS PROTECTORS www.transtech.com.au TRANSTECH ELECTRONIC CONTROLS Electronic Transient Surge Protection Transtech Electronic Controls Pty Ltd ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: (03) 9330-3624 Info@transtech.com.au Also in Melbourne - Sydney – Brisbane – Adelaide TRANSTECH DATA SHEET Subject to change without notice MODEL:- TLP-48/RJ45H-4 Transtech Lightning Protector – Ethernet RJ45 TECHNICAL DATA Voltage rating Normal working volt Nominal Current Clamping Volts Impulse Clamping Surge withstand Imax Energy Level 48Volts 1 Amp or less 90Volts line to screen < 600Volts (1kV/us) 0.3kA (8/20usec) Less than 100 joules Characteristics Transmission Speed Insertion Loss Pins 100M bpss < 3.0 dB at 100MHz 1 – 2 and 3 - 6 GENERAL DESCRIPTION GENERAL SPECIFICATION Insulation resistance Connections Operating Temp Storage Temp Mounting Style Dimensions Weight > 10 Megohm RJ45 Female / Female -10 to 70 Deg C -55 to 80 Deg C DIN Rail Female to Female 85mm X 25mm X 40mm 62 grams The TLP-48/RJ45H-4 lightning and transient arrestor provides protection for Ethernet, Twisted Pair Cat 5 ISDN and DSL Network Cables The TLP-48/RJ45H-4 provides very effective protection by limiting the transient over-voltage between the conductor s of Netowrk cable pairs and the screen The TLP-48/RJ45H-4 utilizes fast response gas filled arrestors and Transorbs to provide low let thru voltages for fast transient rise times. The use of low capacitance gas filled arrestors ensures reliable operation at high frequencies with low insertion losses. FEATURES ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Two Stage protection Protection between lines and screen Suitable for 10BaseT and 100BaseT Aluminium housing Field proven technology Low line losses Designed and manufactured to ISO 9001 C-Tick/ CE Compliant Complies with IEC 616431L21-2005 IMPORTED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-48_RJ45H4 new.docx Confidential August 25, 2011 DATA SHEET Subject to change without notice MODEL:- TLP-N/FF Transtech Lightning Protector – Coax Bulkhead +Tag TECHNICAL DATA Voltage rating Normal working volt Nominal Current Clamping Volts Impulse Clamping Surge withstand Energy Level 70Volts 5 Amps or less 90Volts line to screen < 600Volts (1kV/us) 20kA (8/20usec) 400 joules RF Characteristics RF Power Insertion Loss VSWR 50 Watts < 0.2dB at 2GHz 1.07 : 1 @ 1GHz 1.10 : 1 @ 2GHz GENERAL DESCRIPTION GENERAL SPECIFICATION Capacitance Insulation resistance Operating Temp Storage Temp Mounting Style < 1.5pF > 10 Megohm -10 to 80 Deg C -55 to 80 Deg C Bulkhead/Type N Female to Female 67mm X 25mm X25mm 80 grams Dimensions Weight The TLP-N/FF lightning and transient arrestor provides protection for coaxial lines for radio transmitters, receivers or HF party line bus. The TLP-N/FF provides very effective protection by limiting the transient over-voltage between the inner conductor of the coaxial cable and the screen The TLP-N/FF utilizes fast response gas filled arrestors to provide low let thru voltages for fast transient rise times. The use of low capacitance gas filled arrestors ensures reliable operation at high frequencies with low insertion losses. FEATURES TLP-N/FF 12 mm 22 mm ♦ ♦ ♦ 20 mm 56 mm DIMENSIONS 25 mm ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between line and screen Bulkhead mounting with additional fixed “bolt-thru” earth tag Field proven technology Low line losses Designed and manufactured to ISO 9001 C-Tick/ CE Compliant IEC 1000-4-2 & EN50082 AS 1768-2003 DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-N_FF new.doc Confidential August 20, 2011 DATA SHEET Subject to change without notice MODEL:- TLP-F/FF Transtech Lightning Protector – Coax Type F Cables TECHNICAL DATA Voltage rating Normal working volt Nominal Current Clamping Volts Impulse Clamping Surge withstand Energy Level 70Volts 5 Amps or less 90Volts line to screen < 700Volts (1kV/us) 20kA (8/20usec) 400 joules RF Characteristics RF Power Insertion Loss VSWR 50 Watts < 0.5dB at 2GHz < 1.3 GENERAL DESCRIPTION GENERAL SPECIFICATION Capacitance Insulation resistance Operating Temp Storage Temp Mounting Style Dimensions Weight < 1.5pF > 10 Gigohm -10 to 80 Deg C -55 to 80 Deg C Type F Female to Female 52mm X 25mm X25mm 50 grams The TLP-F/FF lightning and transient arrestor provides protection for coaxial lines for radio transmitters, receivers or HF party line bus. The TLP-F/FF provides very effective protection by limiting the transient over-voltage between the inner conductor of the coaxial cable and the screen The TLP-F/FF utilizes fast response gas filled arrestors to provide low let thru voltages for fast transient rise times. The use of low capacitance gas filled arrestors ensures reliable operation at high frequencies with low insertion losses. FEATURES TLP-F/FF 12 mm 21 mm 22 mm 55 mm DIMENSIONS 25 mm ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between line and screen Field proven technology Low line losses Designed and manufactured to ISO 9001 C-Tick/ CE Compliant IEC616431:21 IEC 1000-4-2 & EN50082 AS 1768-2003 DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-F_FF new.doc Confidential August 20, 2011 DATA SHEET Subject to change without notice MODEL:- TLP-F/MF Transtech Lightning Protector – Coax Type F Cables TECHNICAL DATA Voltage rating Normal working volt Nominal Current Clamping Volts Impulse Clamping Surge withstand Energy Level 70Volts 5 Amps or less 90Volts line to screen < 700Volts (1kV/us/V) 20kA (8/20usec) 400 joules RF Characteristics RF Power Insertion Loss VSWR 50 Watts < 0.5dB at 2GHz <1.3 GENERAL DESCRIPTION GENERAL SPECIFICATION Capacitance Insulation resistance Operating Temp Storage Temp Mounting Style Dimensions Weight < 1.5pF > 10 Gigohm -10 to 80 Deg C -55 to 80 Deg C Type F Male to Female 52mm X 25mm X25mm 50 grams The TLP-F/MF lightning and transient arrestor provides protection for coaxial lines for radio transmitters, receivers or HF party line bus. The TLP-F/MF provides very effective protection by limiting the transient over-voltage between the inner conductor of the coaxial cable and the screen The TLP-F/MF utilizes fast response gas filled arrestors to provide low let thru voltages for fast transient rise times. The use of low capacitance gas filled arrestors ensures reliable operation at high frequencies with low insertion losses. FEATURES TLP-F/MF 12 mm 20 mm 22 mm 56 mm DIMENSIONS 25 mm ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Low “let thru” voltage Protection between line and screen Field proven technology Low line losses Designed and manufactured to ISO 9001 C-Tick/ CE Compliant IEC616431:21 IEC 1000-4-2 & EN50082 AS 1768-2003 DESIGNED & MANUFACTURED in AUSTRALIA by: Transtech Electronic Controls Pty Ltd Perth W.A. ABN: 21 070 629 499 Design changes may occur in the interests of product performance & development E&OE Page 1 of 1 ISSUE A / Rev A I:\Shared\Engineering Dept\DataSheets & Product Packet Labels\TLP-F_MF new.doc Confidential August 20, 2011 TransTech Electronic Controls Pty Ltd ABN 21 070 629 499 A GUIDE TO SPECIFYING ELECTRONIC SURGE PROTECTION DEVICES Preface: This document is meant as a guide to those involved in specifying, applying and/or approving electronic transient protection devices. It is by no means a definitive paper on the types of transient surge protection available nor in any way proposes to set out a particular manufacturer, type or technique. This guide does not address “structural lightning protection” other than to direct the reader to the Australian Standard AS NZS 1768:2005 and in particular to the proven techniques for effective structural lightning design and installation. Good structural protection and earthing/bonding is an essential part of minimizing possible effects from lightning transients. The most important consideration for any Engineer specifying electronic transient protection is the “letthru” voltage as this is critical to the proper functioning of the electronic/electrical equipment it is intended to protect following a transient. The critical considerations in specifying electronic transient protectors are: 1. 2. 3. 4. 5. Be compatible with the system it is protecting Survive transients and contain any fault condition arising Have a low “let-thru” voltage for ALL conductor combinations Not fail and leave the installation un-protected Be correctly installed and maintained regularly. 1. Compatibility The protector should not inhibit the systems normal operation if it operates 2. Survival & housing Transients from a lightning strike (close proximity) can exceed 200,000 amps, however statistically the average transient is approx 10,000 amps. The IEC Standard uses 10,000 amps as the accepted “norm”, however AS1768 has adopted 70,000 amps therefore any protector at a point of entry should have a rating equal to or exceeding 70,000 amps to meet the current Australian Standard. It is recommended by the leading MOV suppliers that surge protectors incorporating such devices be constructed of metal as a safety precaution Clause 7.9.2 of IEC61643-1:2005 addresses this aspect. 3. Let-thru voltage The magnitude of the transient reaching the electronic/electrical equipment is critical and can cause anything from data-corruption to flash-over and arcing damage. The suitable protector should therefore offer a let-thru voltage less than the maximum voltage rating for the equipment (the current IEC states 2.5kV as the minimum insulation level). Transients occur between all conductors of a system – that is: Ph-N / Ph-E / N-E and in instrumentation and data-line circuits both Common Mode and Differential Mode. Protectors need to offer such levels of protection 4. Indication of failure In-line protectors such as used for 120/240vac sub-circuit, instrumentation and/or data-lines are inherently “self-revealing” upon a major transient as the circuit invariably goes open. In Main Board protection systems it is essential to have an indication to warn of failure or degradation of the protective devices, such indication should be both local visual and a relay output. 5. Installation The performance of transient protectors depends upon correct installation as they are required to manage high frequency waveforms, therefore the length and size of connecting cables must be considered, as a guide refer to AS4070:1992. As a rule of thumb the larger the cross section and the shorter the cable the better, 500mm of 6 sq mm cable is recommended as a minimum. I:\Shared\Price Lists & data sheets\Transtech\Application Notes\surge protection guide.docx Updated: 15/11/2011/ TransTech Electronic Controls Pty Ltd ABN 21 070 629 499 SUGGESTED SPECIFICATION 1.1 Point-of-Entry Main & Sub Distribution Boards. Provide lightning/transient surge suppression to the mains supply of the main switchboard and each sub distribution board. Supply, install and connect a … insert similar product of equivalent function and quality to the satisfaction of the Engineer. Such rating to be no less than 70kA surge capacity according to IEC 61643.1 and are to include all 3 phases plus Neutral and offer true 3 mode protection. Manufacturer(s)…., or The installation shall be strictly in accordance with the Manufacturers recommendations. 1.2 Final Sub Circuits Where indicated on power circuit schedules a series filter surge protector shall be fitted to protect individual circuits. The series filters shall be …. Insert manufacturer(s)…...or similar product equivalent in function, size and quality to the approval of the Engineer. Rating shall be no less than 24kA according to IEC 61643.1 and offer true 3 mode protection. The surge device shall be compatible with any RCD protection and protect against high frequency noise and transient surges in all modes (L-N, L-E, N-E). The series protectors shall be constructed to meet UL 1449 and be Third Party tested to IEC61643.1. Where alternatives are offered the tenderer shall provide sufficient data to prove that the alternative complies with the specification. All transient/surge protection devices shall be mounted to protrude thru the distribution board escutcheon plate and shall have visible status indication. Where nominated such series surge filters shall have in addition an incorporated relay that monitors the health of the protection device and provides a volt-free changeover contact for monitoring by the Building Management System (BMS). I:\Shared\Price Lists & data sheets\Transtech\Application Notes\surge protection guide.docx Updated: 15/11/2011/ TransTech Electronic Controls Pty Ltd ABN 21 070 629 499 SURGE CURRENT CAPACITY & FUSING REF: AS/NZS 1768:2005 1. INTRODUCTION The committees of all International Standards, after years of research have decided that the average indirect lightning surge is only 10kA, Standards Australia, however, via AS1768:2005 Table F1 states 70kA as a maximum indirect lightning surge value, Transtech has therefore taken the decision to meet the higher level as detailed by Standards Australia and as a consequence the main board of the TLP range of Surge Protectors is designed to withstand multiple transient surges of 70kA and a single surge of 140kA. NOTE: The fault rating assigned to a Mains Surge Protector is not to be confused with the switchboard bus bar fault rating. A transient/lightning surge rating is based upon an 8/20micro second waveform therefore a duration of only 28 microseconds. 2. DESIGN OF TRANSTECH MAINS PROTECTORS Transtech Electronic Controls Pty Ltd has been designing and manufacturing electronic transient/surge protectors since 1996 and has supplied some of Australia’s biggest Companies not to mention delivering over 15,000 pcs of its 20Amp single phase series filters to the BER Project Australia Wide. Based upon the preceding information, Transtech Electronic Controls Pty Ltd designs its TLP Mains Surge Protectors with high quality 70micron copper board and accurately calculated track sizing designs. Surge protectors with ratings above 70kA simply offer extended lifetimes to users. 3. PROTECTING A TLP MAINS PROTECTOR Protection of a Mains Surge Protector is governed according to AS3000. It is a requirement to protect the circuit with either an HRC Fuse or a MCB, the HRC Fuse or MCB size is determined firstly by the Fault Rating of the Switchboard and secondly by the wire size supplying the TLP. 3.1.1. SWITCHBOARD FAULT RATING This refers to the bus bar fault level, therefore any protection device such as an HRC Fuse or a MCB must be in accordance with suppliers ratings and application advice (an example being Schneider Cascading & Enhanced Discrimination tables) 3.1.2. WIRE SIZE Transtech Electronic Controls Pty Ltd recommends the maximum size wire to connect a TLP 2 Mains Protector – that is 16 mm therefore according to AS3000 Table B2 the HRC Fuse or MCB shall be 50 amps maximum. 3.1.3. PROTECTION SELECTION (amp rating) As per preceding comments, either an HRC Fuse or MCB is required to protect and provide isolation for the Mains Surge Protector. The factors to be considered in the selection of a suitable primary protection device are as per Clauses 3.1.1 and 3.1.2 above. The current rating of the HRC or MCB should be between 25 amps and 50 amps. I:\Shared\Price Lists & data sheets\Transtech\Application Notes\fault rating design and fuse sizes.docx TransTech Electronic Controls Pty Ltd ABN 21 070 629 499 SUMMARY. A. Transtech Electronic Controls Pty Ltd follows AS1768:2005 and all other relevant Standards in its designs and meets them regarding surge fault ratings. B. Transtech Electronic Controls Pty Ltd Mains Surge Protectors cover all Category’s E / D / C / B / A C. Transtech Electronic Controls Pty Ltd manufactures Mains Surge Protectors offering Surge Fault ratings in excess of 70kA, these simply offer the user extended lifetime. D. The fault ratings of the TLP Mains Surge Protectors should not be confused with switchboard bus bar fault ratings. E. All Transtech Mains Surge Protectors type TLP’s have internal MOV protection fuses suitable to break 100Amps. F. The fault rating of a TLP Mains Surge Protector is based upon a very short time of 28 microseconds, not to be confused with a typically 1sec rating as for switchboard Type Tests. G. Transtech Electronic Controls Pty Ltd has been designing electronic surge protectors for over 16 years and accurately designs the circuit board layout in its TLP series to withstand a 70kA 8/20 microsecond surge. H. PROTECTION TABLE: TLP MODEL RECOMMENDED DEVICE AMPS COMMENT TLP-SF20SL-240V TLP-40-xP TLP-80-xP TLP-120-xP TLP-160-xP TLP-200-xP TLP-240-xP HRC HRC HRC MCB MCB MCB MCB 25 40 50 50 50 50 50 Single phase series filter I:\Shared\Price Lists & data sheets\Transtech\Application Notes\fault rating design and fuse sizes.docx MCB’s not tripped by transient MCB’s not tripped by transient MCB’s not tripped by transient MCB’s not tripped by transient Transtech Electronic Controls Pty Ltd Australian Agent for: HAZARDOUS AREA ENCLOSURES HIGH SPEED SENSORS & TACHOS ALARM ANNUCIATORS ENCODERS AND TECHOS HAZARDOUS AREA FLOW/TEMP/PRESSURE PROXIMITY SENSORS & PE CELLS Transtech Electronic Controls Pty Ltd Also in Sydney – Brisbane – Adelaide TRANSTECH ABN 21 070 629 499 Perth - Melbourne Perth Tel: (08) 9302-2044 Melbourne Tel: 0400 848-064 Info@transtech.com.au