Master Index Cat. No. Index J Index January 2002 Explosion-Proof Junction Unilets Features: Junction Boxes Outlet Boxes Master Index January 2002 J Index Cat. No. Index J-1 Compliance Data: CSA Approved Class I, Div. 1 and 2, Groups B, C, D; Class I Zone 1 and 2, IIB + H2 T6 Class II, Div. 1 and 2, Groups E, F, G; Class III, Enclosure 3, weatherproof EEMAC Type 3R, 7BCD, 9EFG 99 Union Street Elmira, Ontario N3B 3L7 J-2 Cat. No. Index Master Index October 2008 J Index Explosion-Proof Junction Unilets GR GRF GRUE-200 GRSS ELBY GRJ GRJS CPU ER EXB ELBD Page Description 3-4 GR Junction Unilets 5 Covers and Canopies 4 GRF Junction Unilets 5 Covers and Canopies 6 GRUE-100 Universal Junction Boxes 7 GRUE-200 Universal Junction Boxes 8 GRSS Conduit Outlet Boxes 9 ELBY Capped Elbows 10 GRJ Junction Unilets 11 Covers 11 GRJS Junction Unilets 12 CPU Universal Outlet Boxes 13 ER Junction Unilet 14 EXB Cast Iron Junction Boxes 15 Ordering Information, Tapping and Drilling Information 16 ELBD 90° Pulling Unilets 17-19 DER and GUB Junction Unilets 18 Ordering Information 19 Covers 20 GUBM Instrument Unilets 21, 22 Dimensions - DER and GUB 23 GRU Conduit Outlet Boxes with Union Hubs 23 GRUT and GRUSE Union Hubs, Dimensions 24 Wiring Capability - Conduit Outlet Boxes GUB/DER GRU 99 Union Street Elmira, Ontario N3B 3L7 October 2008 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index January 2002 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 J-3 GR Junction Unilets, Malleable or Copper-Free* Aluminum: Explosion-Proof, Dust-Ignition-Proof, and Weather Resistant (Raintight) Malleable Iron Cat. No. Illustration Aluminum Catalogue Number GRE50 GRE75 GRE100 GRE125 GRE150 GRE50-A GRE75-A GRE100-A GRE125-A GRE150-A GRC50 GRC75 GRC100 GRC125 GRC150 GRC200 GRC50-A GRC75-A GRC100-A GRC125-A GRC150-A GRC200-A GRL50 GRL75 GRL100 GRL125 GRL150 GRL200 GRL50-A GRL75-A GRL100-A GRL125-A GRL150-A GRL200-A GRLB50 GRLB75 GRLB100 GRLB125 GRLB150 GRLB200 GRLB50-A GRLB75-A GRLB100-A GRLB125-A GRLB150-A GRLB200-A GRN50 GRN75 GRN100 GRN125 GRN150 GRN50-A GRN75-A GRN100-A GRN125-A GRN150-A GRT50 GRT75 GRT100 GRT125 GRT150 GRT200 GRT50-A GRT75-A GRT100-A GRT125-A GRT150-A GRT200-A GRX50 GRX75 GRX100 GRX125 GRX150 GRX200 GRX50-A GRX75-A GRX100-A GRX125-A GRX150-A GRX200-A Cover Form Opening Number Description 1/2 3/4 1 1-1/4 1-1/2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 1 1 1 2 3 GRC 1/2 3/4 1 1-1/4 1-1/2 2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 4-7/8 1 1 1 2 3 3 GRL 1/2 3/4 1 1-1/4 1-1/2 2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 4-7/8 1 1 1 2 3 3 GRLB 1/2 3/4 1 1-1/4 1-1/2 2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 4-7/8 1 1 1 2 3 3 GRN 1/2 3/4 1 1-1/4 1-1/2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 1 1 1 2 3 GRT 1/2 3/4 1 1-1/4 1-1/2 2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 4-7/8 1 1 1 2 3 3 GRX 1/2 3/4 1 1-1/4 1-1/2 2 3-3/8 3-3/8 3-3/8 3-15/16 4-7/8 4-7/8 1 1 1 2 3 3 GRE NOTE: All GR boxes above are supplied with O-ring. See page 5 for other covers available. If no covers are desired, specify catalogue number with suffix “LC”, and deduct price of cover. Form numbers indicate sizes of unilets which take correspondingly classified covers. Master Index January 2002 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-4 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Cat. No. Index Master Index January 2002 J Index GR and GRF Junction Unilets, Malleable or Copper-Free** Aluminum Explosion-Proof, Dust-Ignition-Proof, and Weather Resistant (Raintight) Catalogue Number Malleable Iron Aluminum Description Conduit Size Cover Opening Form Number GR Junction Unilets Furnished with externally threaded surface cover GRCA50 GRCA75 GRCA50A GRCA75A GRCA 1/2 3/4 3-3/8 3-3/8 1 1 GRLA50 GRLA75 GRLA50A GRLA75A GRLA 1/2 3/4 3-3/8 3-3/8 1 1 GRTA50 GRTA75 GRTA50A GRTA75A GRTA 1/2 3/4 3-3/8 3-3/8 1 1 Cover Opening Form Number NOTE: All above are supplied with rear hub. Form 1 1 1 2 3 Hub Sizes 1/2 3/4 1 1-1/4 1-1/2 Catalogue Number Malleable Iron Aluminum A B C D E 3-3/4 3-3/4 3-3/4 4-1/2 5-3/4 2-3/8 2-3/8 2-3/8 2-11/16 3-3/4 3-1/16 3-1/16 3-1/16 3-5/16 4-3/8 21/32 21/32 15/16 1-5/32 1-3/8 11/16 11/16 13/16 7/8 1-5/16 Conduit Size Description Furnished with externally threaded surface cover GRFC50 GRFC75 GRFC100 GRFC50A GRFC75A GRFC100A GRFC 1/2 3/4 1 3-3/8 3-3/8 3-3/8 1 1 1 GRFL50 GRFL75 GRFL100 GRFL50A GRFL75A GRFL100A GRFL 1/2 3/4 1 3-3/8 3-3/8 3-3/8 1 1 1 GRFT50 GRFT75 GRFT100 GRFT50A GRFT75A GRFT100A GRFT 1/2 3/4 1 3-3/8 3-3/8 3-3/8 1 1 1 GRFX50 GRFX75 GRFX100 GRFX50A GRFX75A GRFX100A GRFX 1/2 3/4 1 3-3/8 3-3/8 3-3/8 1 1 1 NOTE: All GR boxes above are supplied with O-ring. GRF Flanged Junction Unilets GRF junction unilets are similar in design and size to GR junction unilets, except they are supplied with a mounting flange. The flanged surface has four 3/8" holes. Unilets are furnished with externally threaded surface cover and threaded hubs. When used with canopy or hub style covers listed on page 8, they are particularly well suited for hanging pendant lighting fixtures. Hub Size A B 1/2, 3/4 and 1 2-5/16 5/8 3-3/4 C D E 5-3/8 F 3-3/8 3/8 See page 5 for other covers available. If no covers are desired, specify catalogue number with suffix “LC”, and deduct price of cover. Form numbers indicate sizes of unilets which take covers correspondingly classified. 99 Union Street Elmira, Ontario N3B 3L7 January 2002 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index January 2002 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 J-5 Covers for GR and GRF Conduit Outlet Boxes Covers and O-rings fit bodies with corresponding form numbers. Cover Type Cover Opening (Inches) Fixture Stem Size (Inches) Catalogue Number Form No.† Malleable Iron Aluminum Surface 3.38 3.94 4.88 1 2 3 GRK-1M GRK-2M GRK-3M GRK-1 GRK-2 GRK-3 Sealing 3.38 3.94 4.88 1 2 3 GRK-1SC GRK-2SC GRK-3SC GRK-1SC-A GRK-2SC-A GRK-3SC-A 3.38 1 Dome 2" deep GRK-1DC Union Hub 3.38 3/4 1 GRK-75U GRK-75UA Hub 3.38 3.38 1/2 3/4 1 1 GRK-50 GRK-75 GRK-50-A GRK-75-A Canopy 3.38 3.38 3.38 1/2 3/4 1 1 1 1 GRK-50C GRK-75C GRK-100C 1 2 3 GRG-1 GRG-2 GRG-3 Length 4 1/2" O-Rings—Neoprene Provide Raintight fit when used on following series: GR (Forms 1, 2 and 3), GRF (Form 1), GRH and GRU (Form 1). GRTB Terminal Strip For use in standard GR series boxes Weidmuller type MK terminal Block* with wire range of #22-#12 AWG. Mounts on 2 predrilled and tapped standard holes (furnished in internal GR boxes). 6 position terminal block kit 6 position terminal block kit 12 position terminal block kit 1+2 3 3 GRTB6-12 GRTB6-3 GRTB12-3 *Terminal block is UL Listed for 300 volts, 25 ampere. CSA certified for 300 volts, 13 ampere. †Form numbers designate cover and matching body sizes. Master Index January 2002 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-6 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Cat. No. Index Master Index December 2004 J Index GRUE-100 Universal Junction Box: Explosion-Proof and Dust-Ignition-Proof Unilets® for 1/2", 3/4" and 1" threaded metal conduit.‡ Hub Size Hub Configuration Catalogue Number Ferrous Alloy Aluminum GRUE-100 Universal Junction Box Furnished with internally threaded surface cover, five threaded hubs and three close-up plugs. 1/2 3/4 1 XB GRUE-50 GRUE-75 GRUE-100 GRUE-50-A GRUE-75-A GRUE-100-A GRUC-SC-F GRUC-SC GRUE Sealing Cover Sealing cover for GRUE-100 and GRUE-100N junction boxes listed above. To order GRUE-100 and GRUE-100N complete with sealing cover add suffix -SC. GRUE-100/GRUE-100N Dimensions: Hub Size 1/2 3/4 1 H 3/4 1.9cm 3/4 1.9cm 7/8 2.2cm ‡ To order GRUE Universal Junction Boxes for 1-1/4", 1-1/2" and 2", see next page. 99 Union Street Elmira, Ontario N3B 3L7 December 2004 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index January 2002 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 J-7 GRUE-200 Universal Junction Box: Explosion-Proof, Dust-Ignition-Proof Unilets® for 1 1/4", 1 1/2" and 2" threaded metal conduit. Hub Size Hub Configuration Catalogue Number Ferrous Alloy Aluminum GRUE-200 Universal Junction Box Furnished with internally threaded surface cover. Entries are supplied as listed. Master Index January 2002 J Index Cat. No. Index 1-1/4 1-1/2 2 C GRUE-125C GRUE-150C GRUE-200C GRUE-125C-A GRUE-150C-A GRUE-200C-A 1-1/4 1-1/2 2 CB GRUE-125CB GRUE-150CB GRUE-200CB GRUE-125CB-A GRUE-150CB-A GRUE-200CB-A 1-1/4 1-1/2 2 E GRUE-125E GRUE-150E GRUE-200E GRUE-125E-A GRUE-150E-A GRUE-200E-A 1-1/4 1-1/2 2 L GRUE-125L GRUE-150L GRUE-200L GRUE-125L-A GRUE-150L-A GRUE-200L-A 1-1/4 1-1/2 2 LB GRUE-125LB GRUE-150LB GRUE-200LB GRUE-125LB-A GRUE-150LB-A GRUE-200LB-A 1-1/4 1-1/2 2 T GRUE-125T GRUE-150T GRUE-200T GRUE-125T-A GRUE-150T-A GRUE-200T-A 1-1/4 1-1/2 2 TB GRUE-125TB GRUE-150TB GRUE-200TB GRUE-125TB-A GRUE-150TB-A GRUE-200TB-A 1-1/4 1-1/2 2 X GRUE-125X GRUE-150X GRUE-200X GRUE-125X-A GRUE-150X-A GRUE-200X-A 1-1/4 1-1/2 2 XB GRUE-125XB GRUE-150XB GRUE-200XB GRUE-125XB-A GRUE-150XB-A GRUE-200XB-A 99 Union Street Elmira, Ontario N3B 3L7 J-8 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Cat. No. Index Master Index January 2002 J Index GRSS Conduit Outlet Boxes with Multiple Hubs, Explosion-Proof, Dust-Ignition-Proof UNILETS® for use with threaded metal conduit. Furnished with internal ground screw. Box Type Conduit Size (In.) Cover Opening (Inches) Hubs Plugs Catalogue Number Aluminum GRSS Outlet Box with Cover Internally threaded aluminum bodies with externally threaded aluminum form 1 covers. Has 7 hubs; 2 on each of the sides, 1 on the top, 1 on the bottom and 1 on the centre in the back. Furnished with 4 close-up plugs GRSS 1/2 3/4 1 3.38 3.38 3.38 7 7 7 4 4 4 GRSS50 GRSS75 GRSS100 GRSSA Outlet Box with Cover Internally threaded aluminum bodies with externally threaded aluminum form 1 covers. Has 13 hubs; 2 on each side, 2 each on top and bottom and 5 in the back. Furnished with 5 close-up plugs GRSS 1/2 3/4 3.38 3.38 13 13 5 5 GRSSA50 GRSSA75 Dimensions *In Group B atmospheres, all conduit runs must have a sealing fitting (not supplied) field installed adjacent to the enclosure. 99 Union Street Elmira, Ontario N3B 3L7 January 2002 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index January 2002 CSA Approved Class I, Div. 1 and 2 Groups B, C, D; Class I, Zone 1 and 2, IIIB + H2 T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 J-9 ELBY Capped Elbows for Junction Unilets: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant Capped Elbows with Threaded Cover Class I, Groups B, C & D; Class II, Groups E, F & G; and Class III; CSA Encl.3. Pulling elbows have been designed for wiring in hazardous locations. Compact, they have an externally threaded cover opening. The 45° angle of the opening to the large wiring chamber allows conductors to be pulled through the unilet. Size 1/2 3/4 1 1-1/4 A 1-7/16 1-7/16 1-7/8 2-15/16 B 2-7/8 3 3-5/8 4-1/2 C D 2-17/32 2-5/8 2-3/8 3-3/16 1-7/16 1-7/16 1-3/4 2-1/8 Size (inches) Catalogue Number Aluminum† Ferrous Alloy 1/2 3/4 1 1-1/4 ELBY-50A ELBY-75A ELBY-100-A ELBY-125-A ELBY-50 ELBY-75 ELBY-100 ELBY-125 *Nominal diameter of unilet opening. Cadmium finish. †Copper free (Max. 4/10 of 1% copper content). Master Index January 2002 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-10 CSA Approved Class I, Div. 1 and 2 Groups C, D; Class I, Zone 1 and 2, IIB T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Master Index January 2002 J Index GRJ Junction Unilets: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant (Raintight) Applications • The Appleton GRJ unilet has been designed to meet the demand for a very small round unilet for general wiring purposes in hazardous areas. Hub Size 1/2 and 3/4 Features • Bodies have external threads around cover opening, and the covers are threaded internally. Unilet opening is 2-1/8". Illustration Cat. No. Index Catalogue Number A B 2-7/8 2-5/16 Description C D E F 1-15/16 2-1/4 3-15/16 11/16 STD. PKG. WT. LBS. Per 100 Furnished with internally threaded surface cover GRJC50 GRJC75 GRJC 1/2 3/4 5 5 153 150 GRJCA50 GRJCA75 GRJCA 1/2 3/4 5 5 173 160 1/2 3/4 5 5 160 144 GRJEA50 GRJEA75 Includes a rear hub. GRJEA Includes a rear hub. GRJL50 GRJL75 GRJL 1/2 3/4 5 5 156 150 GRJT50 GRJT75 GRJT 1/2 3/4 5 5 178 175 GRJTA50 GRJTA75 GRJTA 1/2 3/4 5 5 180 180 1/2 3/4 5 5 192 200 GRJX50 GRJX75 Includes a rear hub. GRJX Cadmium Finish. See page 11 for other covers available. 99 Union Street Elmira, Ontario N3B 3L7 January 2002 Master Index Cat. No. Index J Index Master Index J Index J-11 Cat. No. Index December 2006 CSA Approved Class I, Div. 1 and 2 Groups C, D; Class I, Zone 1 and 2, IIB T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Illustration GRJ Covers and GRJS Universal Unilets and Covers: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant (Raintight) Catalogue Number STD. PKG. Description WT. LBS. Per 100 Covers for GRJ Junction Unilets Furnished with internal threads. GRJK-S Surface Cover 5 45 GRJK-SC Sealing Cover 5 70 GRJS Universal Junction Unilets and Covers Applications • The Appleton GRJS Universal Junction Unilet is ideal for use in hazardous locations. Features • The Unilet has five threaded hubs, one in each of four sides and one in bottom. Three close-up plugs are furnished. Unilet opening is 2-9/16". Illustration Catalogue Number Hub Size A B C D E 1/2, 3/4 and 1 2-5/8 3-3/4 3-3/4 1 3-1/16 STD. PKG. Description WT. LBS. Per 100 GRJS Universal Junction Unilets Furnished with externally threaded blank surface cover and three close-up plugs. GRJS50 GRJS75 GRJS100 1/2 3/4 1 5 5 5 255 250 234 Supplied with O-Ring. Add suffix -A for aluminum Covers for GRJS Universal Junction Unilets Furnished with internal threads. Master Index J Index GRJSK Surface Cover 5 30 GRJSK-SC Sealing Cover 5 38 GRJSK-50 1/2" Hub Cover 5 70 December 2006 Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-12 CSA Approved Class I, Div. 1 and 2 Groups C, D; Class I, Zone 1 and 2, IIB T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 Cat. No. Index Master Index January 2002 J Index CPU Universal Outlet Box: Explosion-Proof and Dust-Ignition-Proof Description Hub Size Fixture Stem Size Aluminum* Ferrous Alloy CPU20A CPU20 CPU Box with blank cover Furnished with cover screws, four 3/4" universal hubs, four 3/4" to 1/2" reducers and three 1/2" close-up plugs. 1/2" or 3/4" To order with CB205 connection block installed add suffix -CB. CPU Box with hub cover (Supports lbs – 112.5 kg) Furnished with hub cover, screws, four 3/4" universal hubs, four 3/4" to 1/2" reducers and three 1/2" close-up plugs. 1/2" or 3/4" 1/2" or 3/4" 1/2" 3/4" CPU20-50A CPU20-75A CPU20-50 CPU20-75 To order with CB205 connection block installed add suffix -CB. CPU covers only (Form 20) Furnished with fastening screws. Blank Hub Hub — 1/2" 3/4" CPSK20B-A CPSK20-50A CPSK20-75A CPSK20B CPSK20-50 CPSK20-75 CPU replacement connection block With fastening strap and two mounting screws. CB205 5 Wire - 20 Ampere - 300 Volt To order with box - see above. CPU Universal Outlet Box Dimensions: 45° 10-24 Ground Screw 2.88" (7.38cm) 4.81" 12.2cm) .75” (1.9 cm) 1/4–20 Thd. 4 Holes 10-24 Thd. 2 Holes (on boxes with suffix “CB” only) 5.56" (14.1 cm) 1.84” 4.6 cm) 4.63” 11.8 cm) 3.75” (9.5 cm) 7.38" (18.7 cm) 6.38" (16.2 cm) 5/16" Dia. 2 Holes .31” (.78 cm) 2.00” (5.1 cm) *Copper free (4/10 of 1%) 99 Union Street Elmira, Ontario N3B 3L7 January 2002 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index January 2002 CSA Approved Class I, Div. 1 and 2 Groups D; Class I, Zone 1 and 2, IIB T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 3 J-13 ER Junction Unilets: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant (Raintight) Applications • ER Junction Unilets are ideally suited for installations where space is restricted. Hub Size A Features • Their rectangular shape provides a junction unilet as narrow as practical, yet with ample wiring space. • A ground surface contact between unilet and cover insures a flame tight joint. Illustration 1/2 3/4 Catalogue Number B 3-11/16 1-1/2 1 1-3/4 C D E G 1-13/16 5 2-7/16 2-1/8 9/16 2 5-7/16 2-11/16 2-7/16 11/16 STD. PKG. Description F WT. LBS. Per 100 Furnished with blank cover. Master Index January 2002 J Index Cat. No. Index ERC50 ERC75 ERC 1/2 3/4 10 25 158 200 ERLB50 ERLB75 ERLB 1/2 3/4 10 10 155 200 ERLL50 ERLL75 ERLL 1/2 3/4 10 25 158 205 ERLR50 ERLR75 ERLR 1/2 3/4 10 10 160 160 ERT50 ERT75 ERT 1/2 3/4 10 10 168 210 ERTB50 ERTB75 ERTB 1/2 3/4 25 25 175 210 99 Union Street Elmira, Ontario N3B 3L7 J-14 Class I, Div. 1 and 2 Group D Class II, Div. 1 and 2 Groups E, F, G Class III Cat. No. Index Master Index April 2006 J Index EXB Cast Iron Junction Boxes: Explosionproof, Dust-Ignitionproof, Integrally Cast Mounting Feet Drilled and tapped openings 1/2” thru 6” as specified. Features: EXB Series (Cast Iron) • Wide selection of sizes and locations for drilled and tapped openings. • Cast iron box and cover with hot dip galvanized finish. • Extra wide, accurately ground mating surfaces with closely spaced stainless steel hex-head cap screws assure a flame-tight joint. • Provided with mounting lugs. Standard Materials: • EXB: cast iron bodies and covers. Standard Finish: • EXB cast iron bodies and covers: hot-dip galvanized. Compliances: • UL Standard 886. • CSA approved. Factory Installed Options Description Suffix Mounting Plate Hinges WYM* HNG * Refer to page C-14 for Mounting Plate details. Catalogue Number♦ Nom. Inside Dimensions in Inches LxWxD Approx. Side Wall Thickness in Inches Max. Conduit Size (In.) Catalogue Number♦ 2 2 3-1/2 2 3-1/2 EXB040404 EXB060604 EXB060606 EXB080604 EXB080606 18x12x6 18x12x8 18x12x12 18x18x6 18x18x8 0.81 0.81 0.81 0.88 0.88 3-1/2 5 6 3-1/2 5 EXB181206 EXB181208 EXB181212 EXB181806 EXB181808 0.63 0.63 0.63 0.63 0.63 2 3-1/2 5 2 3-1/2 EXB080804 EXB080806 EXB080808 EXB100804 EXB100806 18x18x12 24x12x8 24x12x10 24x12x12 24x18x6 0.88 0.81 0.81 0.81 0.94 6 5 6 6 3 EXB181812 EXB241208 EXB241210 EXB241212 EXB241806 10x8x8 10x10x4 10x10x6 10x10x8 12x8x4 0.63 0.63 0.63 0.63 0.63 5 2 3-1/2 5 2 EXB100808 EXB101004 EXB101006 EXB101008 EXB120804 24x18x8 24x18x10 24x18x12 24x24x8 24x24x12 0.94 0.94 0.94 0.94 0.94 6 6 6 5 6 EXB241808 EXB241810 EXB241812 EXB242408 EXB242412 12x12x4 12x12x6 12x12x8 12x12x10 12x12x12 0.69 0.69 0.69 0.69 0.69 2 3-1/2 5 6 6 EXB121204 EXB121206 EXB121208 EXB121210 EXB121212 30x12x10 30x24x8 30x24x10 30x24x12 1.06 1.06 1.06 1.06 6 5 6 6 EXB301210 EXB302408 EXB302410 EXB302412 18x12x4 0.81 2 EXB181204 Nom. Inside Dimensions (Inches) LxWxD Approx. Side Wall Thickness in Inches Max. Conduit Size (In.) 4x4x4 6x6x4 6x6x6 8x6x4 8x6x6 0.47 0.63 0.63 0.63 0.63 8x8x4 8x8x6 8x8x8 10x8x4 10x8x6 ♦See EXB Ordering Information page for drilling and tapping options. Hinges (Malleable Iron, Hot Dip Galvanized) 99 Union Street Elmira, Ontario N3B 3L7 EXB Box Size Catalogue Number No. of Hinges Per Set Up to 12" x 12" AHNG-22G 2 Up to 24" x 18" AHNG-23G 2 Up to 30" x 12" AHNG-24G 2 Larger than 30" x 12" AHNG-34G 3 April 2006 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index April 2006 J-15 Ordering Information: EXB Boxes: Blank Bodies for Drilling and Tapping Determine catalogue number as follows: (1) select EXB junction box catalogue number; (2) select “Conduit Opening Arrangement Diagram” number; and (3) select symbols that represent conduit opening sizes from “Symbol Table.” Where no opening is required, the symbol 0 must be inserted. Add Suffix for other optional features. The various divisions of the complete catalogue number should be separated by dashes. Example: The junction box selected is EXB181208 with steel mounting plate and the “Conduit Opening Arrangement” is diagram #1. Opening “a” is to be 1/2"; “b”, 1-1/4"; “c”, no opening needed; and “d”, 1-1/2". In this example, the complete catalogue number is: EXB181208—1—AD0E—WYM-1812-1 Minimum Recommended Spacing Between Conduit Openings Allowance made for clearance over bushings. When unions or seals are used, additional space must be allowed. Table shows minimum distances between conduit-opening centerlines in various size combinations. For example, if 1-1/2" and 3/4" openings are to be drilled and tapped into one side of box, the minimum spacing between centerlines would be 2.13". Conduit Size (Inches) 1/2 Minimum space between conduit opening centerlines, Inches 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 1.25 1.38 1.56 1.88 2.00 2.38 2.50 2.88 3.13 3.44 1.50 1.69 2.00 2.13 2.50 2.63 3.00 3.25 3.56 1.88 2.19 2.31 2.69 2.81 3.19 3.44 3.75 2.44 2.63 2.94 3.13 3.44 3.75 4.05 2.75 3.13 3.25 3.63 3.88 4.19 3.44 3.63 3.94 4.25 4.56 3.75 4.13 4.38 4.69 4.44 4.75 5.06 5.00 5.31 5.63 Diameters of Bushings, Unions, Conduit and Seals in Inches Standard Conduit Opening Arrangement Diagrams Opening “a” is always TOP of box. Diag. #1 Diag. #2 Conduit Size (Inches) 1/2 Diameters of Fittings for 1/2" thru 4" Conduit 1-1/4 1-1/2 2 2-1/2 3 3-1/2 3/4 1 4 BBU Bushing BU Bushing UNY/UNF (R) Union Conduit EYM-EYF Seals T.R. 1.06 1.13 1.50 .88 1.06 1.31 1.25 1.75 1.06 1.19 4.88 5.06 6.50 4.50 3.69 1.56 1.63 2.00 1.38 1.38 1.94 2.06 2.81 1.69 1.75 2.19 2.31 3.06 1.94 2.06 2.69 2.94 3.75 2.38 2.31 3.19 3.25 4.94 2.88 2.69 3.88 3.88 5.44 3.50 3.13 4.38 4.56 5.94 4.00 3.44 †T.R. is Turning Radius. Diag. #3 All Conduit Openings will be located in centerline of walls and evenly spaced unless otherwise specified. If a “Standard Conduit Opening Arrangement” is not suitable for the application,or when openings are to be more accurately spaced, submit drill and tap schedule on page J-18. Diag. #4 Symbol Table Drilling and Tapping (Five Threads Min.) Size (in) Symbol Size (in) Symbol Blank 1/2 3/4 1 1-1/4 1-1/2 0 A B C D E 2 2-1/2 3 3-1/2 4 5 6 Master Index April 2006 J Index Cat. No. Index F G H J K L M 99 Union Street Elmira, Ontario N3B 3L7 J-16 Cat. No. Index Master Index April 2006 J Index CSA Approved Class I, Div. 1 and 2 Groups D; Class I, Zone 1 and 2, IIA T6, Class II, Div. 1 and 2 Groups E, F, G; Class III ELBD 90° Pulling Unilets: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant Applications • Appleton ELBD Pulling Units have been designed for hazardous area wiring of motors, panel boards, circuit breakers and other applications. ease and no damage to the insulation of the cable. • An all new exclusive Appleton design has been incorporated into the 2-1/2" through 4" sizes. Rollers have been built into each end of the wiring chamber located so that any resistance caused by bending forces when the cable is pulled through the Unilet are eliminated. Large conductor cables have an unrestricted movement with no damage to insulation. Features • The problems of bending stiff lead covered cables or large conductors have been solved — the angle of the opening to the large wiring chamber allows heavy conductors to be pulled through the ELBD Pulling Unilet with Class I, Group D; Class II, Groups E, F and G and Class III • Appleton ELBD Unilets feature a re- versible dome cover which is bolted to the unilet body with extra hexagon bolts having a screwdriver slot. • Both the cover and the unilet body surface are ground to meet the requirements for hazardous locations. All hubs are chamfered. Standard Materials • ELBD Pulling Unilets: made of malleable iron with cadmium finish. Cover Roller Roller ELBD Pulling Elbow being used to house conductors that supply power to an electrical motor within a hazardous area. ELBD Pulling Unilet showing cover removed. Note exclusive roller feature in each end of wiring chamber. Type and size (inches) Catalogue Number Aluminum Ferrous Alloy 1/2 3/4 1 1-1/4 1-1/2 2 ELBD-50-A ELBD-75-A ELBD-100-A ELBD-125-A ELBD-150-A ELBD-200-A ELBD-50 ELBD-75 ELBD-100 ELBD-125 ELBD-150 ELBD-200 ELBD-250-A ELBD-300-A ELBD-350-A ELBD-400-A ELBD-250 ELBD-300 ELBD-350 ELBD-400 2-1/2 3 3-1/2 4 Patented Roller Feature– Listings in Bold Type Dimensions of ELBD 90° pulling unilets Catalogue Number 99 Union Street Elmira, Ontario N3B 3L7 Hub Size A B C D E F ELBD-50 ELBD-75 ELBD-100 ELBD-125 ELBD-150 ELBD-200 1/2 3/4 1 1-1/4 1-1/2 2 5-1/16 5-1/16 7-7/8 7-7/8 10-5/8 10-5/8 2-19/32 2-19/32 3-7/16 3-7/16 4-13/16 4-13/16 4-1/2 4-1/2 5 5 6-3/4 6-3/4 1-1/16 1-1/16 1-3/4 1-3/4 2-9/16 2-9/16 4-11/16 4-11/16 7-1/2 7-1/2 10-11/16 10-11/16 2-11/16 2-11/16 3-15/16 3-15/16 4-15/16 4-15/16 ELBD-250 ELBD-300 ELBD-350 ELBD-400 2-1/2 3 3-1/2 4 14-11/16 6-19/32 9-1/4 14-11/16 6-19/32 9-1/4 28-1/4 7-1/2 12-3/4 28-1/4 7-1/2 12-3/4 3-3/4 3-3/4 4-5/8 4-5/8 13-13/16 13-13/16 27-9/16 27-9/16 6-11/16 6-11/16 7-3/8 7-3/8 April 2006 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index April 2006 CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 J-17 DER and GUB Junction Unilets: Explosion-Proof, Dust-Ignition-Proof and Watertight Furnished with surface cover and mounting lugs. Catalogue Number Ferrous Alloy DER1C GUB1C GUB2C GUB3C DER1C Catalogue Number Outside Dimensions Cover Dia. 5-1/8 x 5-1/8 x 4-1/16 7 x 7 x 6-1/2 10-5/8 x 9-1/4 x 6-3/4 12-7/16 x 12-7/16 x 8-7/16 3-7/8 5-3/8 7-3/16 9-13/16 Aluminum** DER1CA GUB1CA GUB2CA GUB3CA Maximum size and number of entries supplied on any one side 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Drilled and Tapped - With clearance for conduit seals GUB1C DER1C GUB1C GUB2C GUB3C 3 4 4 4 2 4 4 4 2• 4 4 4 1• 2 3 3 — 2 3 3 — 1 2 2 — — 2• 2 — — — — — — — — — — — — 2• 4 4 4 1• 2 3 3 — 2 3 3 — — 2 2 — — 1• 1 — — — — — — — — — — — — With UNY Male Unions DER1C GUB1C GUB2C GUB3C GUB2C 3 3 4 4 2 3 4 4 Maximum entry in back GUB1C - 2"; GUB2C - 2"; GUB3C - 6" GUB3C •To order DER1C or DER1CA without mounting lugs add the suffix “LF” to the catalogue number. **Copper free aluminum - Maximum copper content 4/10 of 1%. *Requires pad. Available on special order from factory only. Master Index April 2006 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-18 Cat. No. Index Master Index April 2006 J Index DER and GUB Junction Unilets with Surface Cover: Explosion-Proof, Dust-Ignition-Proof and Watertight CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 Determining Catalogue Numbers • To determine the catalogue number of Unilets with entries, the following information should be shown: 1) Unilet catalogue number from listings on page 18. 2) Sketch number of hub arrangement selected from the illustration below. 3) Entry symbols taken from the table shown below. Start from the left (at Hub “A”) on the top of the unilet and continue in rotation clockwise around its body. Where no entry is required, the symbol X should be inserted. The three various divisions of the catalogue number should be separated by dashes. Example GUB2C Unilet is required with threaded conduit entries and unions. The arrangement of entries is per sketch #16. “A” is to be 2" drilled and tapped entry; B—1-1/4", C—Blank (no entry); D—2"; E—Blank; F—1" and J—Blank. The catalogue number is: GUB2C-16-64X634X. Unions are required at B (1-1/4") and D (2"). Order UNY male unions from section I, page 5 (UNY125NR for B; UNY200NR for D). Conduit Entry Symbols Drilling and Tapped or Threaded Hubs Size Symbol Size 1/2 3/4 1 1-1/4 1-1/2 1 2 3 4 5 Union Hubs (GUB4 only) Symbol Size 2 2-1/2 3 3-1/2 4 6 7 8 9 10 1/2 3/4 1 1-1/4 1-1/2 Symbol Size 1E 2E 3E 4E 5E 2 2-1/2 3 3-1/2 4 1 2 3 4 5 6 7 8 9 10 11 A A A A A A A A A A A B B B D B C 12 13 A A E 14 A 15 B J A B 16 B A B E D H A C C C G D H C D 23 24 25 26 27 28 29 A A A ABC ABC ABCD A B J J M L K J C D CBA FED D E F JHG E G C B F D J M C F E 20 A B J D B 19 B C E J 18 B J D C B C 17 A J D J C F B J C E D J M L K J A B B 30 C B C B 21 22 A B E C C C D 31 32 A B A B 33 A B H J C J G F KJHG A B J E L B A 6E 7E 8E 9E 10E J C D E F H G Symbol B A D F E Top* Side* Back Send sketch and description for other arrangements. Front 99 Union Street Elmira, Ontario N3B 3L7 Bottom *GUB2C - Top and bottom measures 9-1/4 x 5-1/2 and sides measure 10-5/8 x 5-1/2. April 2006 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index April 2006 CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 Applications • Suitable for use in hazardous locations. Features • Surface covers furnished with DER and GUB junction unilets have lugs to take a bar or wrench. Other style covers, as listed below, are available. • Sealing covers have a plugged hole through which the unilet can be filled J-19 DER and GUB Junction Unilet Covers Furnished with external threads. with sealing cement after installation. See section I for information regarding sealing cement. Note: When sealing covers are used, splices or taps within the unilets are prohibited by the CEC. • Dome covers permit conductors to be pulled in with the ends extending Catalogue Number GRK-2 GUBK-1 GUBK-2 Type of Unilet well out beyond unilet body where splices can easily be made. • The splices need not be crowded back into the unilet, but can be left as is when dome cover is used for their enclosure and protection. Nominal Depth Inside Diameter Std. Pkg. Wt. Lbs. Per 100 Surface Covers GRK-2C DER1C GUBK-1C GUB1C GUBK-2C GUB2C GUBK-3C GUB3C — — — — 3-9/16 4-5/8 6-1/4 8-7/8 1 1 1 1 75 150 325 625 Sealing Covers GRK-2SC DER1C — 3-9/16 1 176 DER and GUB unilets are furnished with surface covers. Order the remaining above listed covers as follows: Specify unilet catalogue number from the listings on pages 18 thru 21, this section, and the catalogue number of the cover required from the listings above. Example: GUB-2-16-64EX63E4EX (see example from page 19), except with GUBK-2-6 dome cover. DER Form 1 and GR Form 2 have the same cover opening. Master Index April 2006 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-20 Cat. No. Index Master Index April 2006 J Index GUBM Instrument Unilets: Explosion-Proof, Dust-Ignition-Proof and Weather Resistant (Raintight) CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 Applications • Appleton GUBM instrument unilets provide enclosures for meters, gauges or other similar devices in hazardous locations. Features • A heavy, round, explosion-proof glass window in the threaded cover permits direct reading of the enclosed instrument. Illustration • These unilets have mounting lugs and are furnished with a 3/4" threaded entry for rigid conduit. drilled and tapped on proper centres for instruments to be used. No other means of instrument fastening is included in the list price. Instrument mounting plates or brackets can be furnished. On receipt of complete instrument dimensions, prices will be quoted. Call factory for details. Ordering Information • Other hub arrangements and sizes are available. Prices on application. Mounting bosses are provided in the bottom of the unilet which can be Catalogue Number Type unilet Hub size Cover opening* Mtg. lugs GUBM-1C GUB-1C 3/4 5-3/8 2 3/4 7-3/16 2 For Copper-free• aluminum add suffix -A. GUBM-2C GUB-2C For Copper-free• aluminum add suffix -A. Dimensions of GUBM Unilets Catalogue Number Mtg. Lugs A B C D E F G Dia. H Dia. J K Dia. L GUBM-1C 2 7" 7" 6-1/2" 5-1/2" 8-1/4" 6" 3-5/8" 5-3/8" 4-5/8" 1/2" 2-1/16" GUBM-2C 2 5-5/8" 10-3/8" 9-19/32" 5" 7-5/16" 4-3/8" 1/2" 2-1/16" 9-17/64" 10-19/32" 6-23/32" *Nominal diameter of Cover opening. • Maximum Copper Content 4/10 of 1%. 99 Union Street Elmira, Ontario N3B 3L7 April 2006 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index April 2006 J-21 Dimensions: DER and GUB Unilets Explosion-Proof, Dust-Ignition-Proof and Weather Resistant (Raintight) CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 DER1C (2 lugs) GUB1C (2 lugs) GUB2C (2 lugs) Type Unilet DER1C GUB1C GUB2C GUB3C A 5-1/8 7 9-1/4 12-7/16 B 5-1/8 7 10-5/8 12-7/16 C D E 4-3/8 5-3/4 8-1/8 10-15/16 3-29/32 5-13/32 7-1/4 9-7/8 3-29/32 7-3/16 7-3/16 9-7/8 Master Index April 2006 J Index Cat. No. Index All Types GUB3C (4 lugs) F 4 6 9-19/32 9 G 6 8-1/4 10-3/8 14 H 5/16 1/2 1/2 5/8 J K L M N 4-1/16 6-3/8 6-5/8 8-1/8 2-7/16 3-13/16 3-15/16 4-7/16 3-1/4 5-1/32 5-7/32 6-3/16 2-5/16 4-5/8 5-1/16 5-5/8 4-1/2 6-3/16 8 10-3/4 O — — — 7 T — — — 7 U 7 9-1/4 11-3/8 14-15/16 Z — 1/8 1/8 5/16 99 Union Street Elmira, Ontario N3B 3L7 J-22 Cat. No. Index Master Index April 2006 J Index Dimensions: DER and GUB Unilets -Continued CSA Approved Class I, Div. 1 and 2 Groups A, B, C, D; Class I, Zone 1 and 2, IIC T6, Class II, Div. 1 and 2 Groups E, F, G; Class III, Enclosure 4 Dimensional Drawings on preceding page 24 Type Threaded Entries‡ DER1C GUB1C Top or Bottom Side 9-1/4" x 5-1/2" GUB2C GUB3C Left or Right Side 10-5/8" x 5-1/2" GUB2C Entry Size P Q R X Y AA BB 1/2 3/4 1• 1-1/4• 1-7/16 1-7/16 1-7/16• 1-7/16• 1-3/16 1-3/16 1-3/16• — 1-7/16 — — — — — — — — — — — 2 — — — 31/32 — — — — — — — — — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/16 2-1/16 2-1/16 2-1/16 2-1/16 2-1/2 1-7/16 1-7/16 1-7/16 1-7/16 — — 1-3/4 1-3/4 1-3/4 — — — 11/16 11/16 11/16 ■ — — — 1-3/8 1-3/8 1-1/8 ■ — — — 3-3/8 3-3/8 3-3/8 — — — 1-3/4 1-3/4 1-3/4 — — — 3-1/2 3-1/2 3-1/2 ■ — — — 1-11/16 1-11/16 1-11/16■ — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2• 2-1/16 2-1/16 2-1/16 2-1/16 2-1/16 2-5/8 2-5/8• 2-1/16 2-1/16 2-1/16 2-1/16 2-1/16 2-1/4 2-1/4• 2-13/16 2-13/16 2-13/16 2-13/16 2-13/16 ■ — — 1 1 1 — — — — 2 2 2 — — — — 3-5/16 3-5/16 3-5/16 3-5/16 3-5/16 ■ — — 2 2 2 2 2■ — — 3-9/16 3-9/16 3-9/16 — — — — 1-3/4 1-3/4 1-3/4 — — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8 2-3/8• 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 — — 1-3/16 1-3/16 1-3/16 — — — — 2-3/8 2-3/8 2-3/8 — — — — 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 — — 2-11/16 2-11/16 2-11/16 2-11/16 2-11/16 — — 2-11/16 2-11/16 2-11/16 — — — — 3-7/8 3-7/8 3-7/8 — — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2• 2-1/16 2-1/16 2-1/16 2-1/16 2-1/16 2-5/8 2-5/8• 2-1/16 2-1/16 2-1/16 2-1/16 2-1/16 2-1/4 2-1/4• 2-13/16 2-13/16 2-13/16 2-13/16 3-1/8 — — 1 1 1 1-3/16* — — — 2 2 2 2-5/16* — — — 3-5/16 3-5/16 3-5/16 3-5/16 3-5/16 — — 2 2 2 2 2 — — 3-9/16 3-9/16 3-9/16 3-7/16* — — — 1-3/4 1-3/4 1-3/4 1-7/8* — — — CC DD ‡ Dimensions permit assembly of seals on adjacent conduit runs. ■Seals must be staggered for assembly on adjacent conduit runs. • Requires pad. Available only on special order from factory. * Dimensions will not permit assembly of unions on adjacent conduit runs. § Dimensions permit assembly of unions on adjacent conduit runs. Caution: Dimensions between hub centres are for use with hubs of the same size. These dimensions will not necessarily hold true for a combination of hubs of extreme sizes. Please consult Engineering Dept. for special combinations of hubs. 99 Union Street Elmira, Ontario N3B 3L7 April 2006 Master Index Cat. No. Index J Index Master Index Cat. No. Index J Index October 2008 J-23 GRU Conduit Outlet Boxes with Union Hubs: Explosion-Proof and Dust-Ignition-Proof CSA Approved Class I, Div. 1 and 2 Groups C and D; Class II, Div. 1 and 2 Groups E, F, G; Class III NEMA 3, 4* Unilets® for use with Threaded Metal Conduit. Funished with Internal Ground Screw. Box Type Conduit Size (Inches) Cubic Inch Capacity Cover Opening (Inches) Catalogue Number Malleable Iron Aluminum GRU with Union Hubs GRUT 1/2" thru 1" and GRUSE 1/2" thru 3/4" — Malleable iron externally threaded body complete with internally threaded malleable iron surface cover. GRUSE 1" — Copper-free aluminum cover and body with externally threaded cover. GRUT50 GRUT 1/2 3/4 1 19 19 19 3.25 3.25 3.25 GRUT50 GRUT75 GRUT100 GRUSE 1/2 3/4 1 19 19 29 3.25 3.25 3.75 GRUSE50 GRUSE75 GRUSE50 GRUSE100 GRU Covers Malleable iron with internal threads. Fit GRUT and GRUSE listed above†. Surface GRUK-S 3.25 * Applies to GRUSE100 only. †Does not apply to GRUSE100. GRUT Dimensions GRUT GRUSE50 and GRUSE75 Dimensions in Inches Hub Size (Inches) 1/2 3/4 1 A B C D E F 4.19 4.19 4.19 2.69 2.69 2.69 6.25 6.25 6.50 .75 .75 .94 8.25 8.25 8.75 2.31 2.31 2.31 1.9 1.9 2.4 21.0 21.0 22.2 5.9 5.9 5.9 Dimensions in Centimeters 1/2 3/4 1 10.6 10.6 10.6 6.8 6.8 6.8 15.9 15.9 16.5 GRUSE 1/2" and 3/4" GRUSE100 Dimensions in Inches 8.00 min. 4.63 Hub Size (Inches) A B C 1/2 & 3/4 4.19 2.56 6.13 2.38 Ø3.75 4.63 D .94 E F G 8.00 2.19 2.13 Dimensions in Centimeters 1/2 & 3/4 10.6 6.5 15.6 2.4 20.3 5.7 5.4 3.48 Master Index October 2008 J Index Cat. No. Index 99 Union Street Elmira, Ontario N3B 3L7 J-24 Cat. No. Index Master Index October 2008 J Index Wiring Capacity: Explosion-Proof Conduit Outlet Boxes Volume in Cubic Inches and Cubic Centimetres Wiring Capacity CPU ER Type Size CPU Form 20 ER GRJ GRJS GRK GRU Vol./cu. cm 21.0 344.1 1/2" 4.8 78.7 ER 3/4" 7.3 119.3 GR Form 1 18.0 295.0 GR Form 2 31.0 508.0 GR Form 3 (1-1/2") 72.0 1179.9 Form 3 (2") 76.0 1245.4 GRF All 18.0 295.0 GRJ All 7.3 119.3 GRJS All 12.5 204.8 GRK (Canopy) -50°C, -75°C, -100°C 16.0 262.2 GRK (Dome) 1DC 6.0 98.3 GRU (Union Hubs) 1/2", 3/4" 19.0 311.4 GRUE 1/2", 3/4" 15.3 250.7 1" 18.5 303.2 GRSS All 29.0 475.2 GRSSA All 29.0 475.2 GR GRF Vol./cu. in. GRUE-75 GRSS ELBD 90° Pulling Unilets Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 69.0 240.0 240.0 540.0 540.0 Capacity in Cubic Inches ELBD ELBD 7.0 25.0 25.0 69.0 Capacity in Cubic Centimetres ELBD 99 Union Street Elmira, Ontario N3B 3L7 7.0 114.7 114.7 409.7 409.7 1130.7 1130.7 3932.9 3932.9 8849.0 8849.0 October 2008 Master Index Cat. No. Index J Index