COOPER LIGHTING - LUMARK DESCRIPTION The Steeler SG Prismatic Glass Series combines the popular Steeler ballast housing with shock- and impact-resistant prismatic borosilicate glass reflectors for maximum durability and photometric performance. U.L. listed and labeled for damp location. CSA Certified. ® Type Catalog # Project Date The Steeler SG is perfect for manufacturing and assembly areas, retail stores, wholesale warehouses, grocery chains, malls and auto service areas, where up light is desired. FIXTURE AE IS THIS A FIXTURE Comments BUT FED BY A CIRCUIT WITH AN Prepared by INVERTER. SEE INVERTER CUT SHEET ATTACHED. SPECIFICATION FEATURES A ... Mounting Easy slide-on die-cast aluminum mounting box with tapped opening for 3/4" conduit. B ... Housing Heavy-duty, formed steel housing with an open air ballast for cooler operation is finished in a white polyester powder coat. C ... Safety Cable Safety cable attached from housing to reflector standard. F ... Socket Mogul-base porcelain socket. D ... Universal Brackets Universal ladder brackets allow for the flexibility to change out with other reflectors available in acrylic or aluminum. G ... Reflector Easily mounted prismatic borosilicate reflector has multiple adjustable distribution patterns for precise control. Zinc-plated wire form with optional safety glass bottom for durable performance. E ... Ballast High power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40°F) for HPS and -30°C (-20°F) for MH, MP and ML. CSA certified. SG 16" & 21" PRISMATIC GLASS HIGH-BAY 175 - 1000W A High Pressure Sodium Pulse Start Metal Halide Metal Halide B PRISMATIC GLASS HIGH-BAY INDUSTRIAL LUMINAIRE C T E C H N I C A L D AT A D 16" Reflector Maximum height is 24 1/2" [622mm] E F 21" Reflector Maximum height is 25 3/4" [654mm] EISA Compliant 65°C Maximum Ambient Temperature. 90°C Supply Wiring E N E R G Y D AT A CWI Ballast Input Watts 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) CWA Ballast Input Watts 200W MP HPF (227 Watts) 250W MP HPF (283 Watts) 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) 400W MP HPF (452 Watts) 400W HPS HPF (465 Watts) 450W MP HPF (508 Watts) 600W HPS HPF (665 Watts) 750W HPS HPF (850 Watts) 750W MP HPF (820 Watts) 1000W HPS HPF (1100 Watts) 1000W MH HPF (1085 Watts) 1000W MP HPF (1070 Watts) YS C ER Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. T EM S 51 lbs. (23 kgs.) D S H I P P I N G D AT A Approximate Net Weight: S 16" [406mm] or 21" [533mm] TIFIE ADH082393 01/21/2009 3:22:13 PM SG 16" & 21" PRISMATIC GLASS HIGH-BAY ORDERING INFORMATION Sample Number: MPSG-GR16-M-400-MT-Q Lamp Type MP=Pulse Start Metal1 Halide Reflector Type GR=Glass Reflector MH=Metal Halide1, 2 HP=High Pressure Sodium Reflector Diameter 16=16'' Diameter ML=Pulse Start MH 1, 3, 4 (Linear Reactor) 21=21'' Diameter Distribution C=Concentrated 5 Series SG=Steeler Glass M=Medium W=Wide Lamp Wattage Voltage 7 120V=120V MP 208V=208V 240V=240V 175=175W 200=200W 250=250W 320=320W 277V=277V 347V=347V 350=350W 400=400W 480V=480V MT=Multi-Tap, 8 wired 277V 450=450W 750=750W TT=Triple-Tap, 9 wired 347V 1000=1000W 5T=5-Tap10 MH 2 175=175W 250=250W 400=400W 1000=1000W HP 250=250W 400=400W 600=600W6 750=750W Socket 11, 12 OR=Open Rated Socket for Metal Halide Lamps __=Non Applicable (HPS or Not compatible with OR Socket) Open Rated socket and lamp must be used. Notes: 1 2 MH available in non-U.S. markets only. 3 175, 200, 250, 320, 350, 400, 450 and 750W only. 4 277V only, not available with HSW, Q, EM, HL or HC options. 5 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. Otherwise fixture is shipped in medium setting. 6 High Pressure Sodium only. 7 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. 8 Multi-Tap ballast 120/208/240/277V wired 277V. 9 Triple-Tap ballast 120/277/347V wired 347V. 10 5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP fixtures not available in 5-Tap Voltages. 11 Not applicable for HPS. 12 Required for metal halide lamps up to 750W. 13 Requires FH-1or FL-1or SHK. 14 Requires FL-1 and TPPH. 15 Not available with HL or HC options. 16 Uses coated lamp. 17 Lamp is shipped separately. 18 Not available with QD, W or WL options. 19 Not available with QD, PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 20 Order separately. 21 Requires FL-1 and PHC. 22 Requires FL-1 and PHC-XXXV-NEMA. 23 Specify L/TCB when using thru-way mounting box (TWMBS) accessory. Options VI=Visual Indicator system, externally mounted LED Signal Accessories 20 C3=3' Cord-No Plug - Requires FH-1, FL-1, or 13 C3=3' Cord with no plug (Specify Voltage)13 PC3=3' Cord with NEMA Plug (120V-L5-15P, 13 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. PC3=3' Cord with NEMA Plug - (120V-L5, 208V-L6-15P, 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use with TPPH-NEMA. Specify Voltage. PHC=Power Cord and Plug (18" Power Cord 14 and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). PS=Protective Starter (Available in 1000W HPS only. For other wattages consult factory). P=Pre-set Socket Position from the factory FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK PHC=Power Hook Cord and Non-NEMA plug 14 configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook) SGB16/GR=16" Safety Glass Bottom (Not Compatible with WG16/GR) WG16/GR=Wire Guard for 16" Reflector WG21/GR=Wire Guard for 21" Reflector WG16/GLC/GR=Gym Wireguard w/ Safety Glass Bottom for 16" Reflector WG16/SGB16A=Gym Wire Guard with Safety Glass Bottom for 16" Refractor GTWG16=Glass Top Wire Guard GFWG16/WG16=Glass Full Wire Guard GTWG21=Glass Top Wire Guard WG21/GLC/GR=Gym Wireguard w/ Safety Glass Bottom for 21" Reflector GFWG21/WG21=Glass Full Wire Guard SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) TPPH=Thru-Way Pendant Power Hook. 21 Requires FL-1 and PHC. Specify Voltage. SS=Space Saver Feature F1=Single Fuse (120, 277 or 347V only) TPPH-F=Thru-Way Pendant Power Hook 21 Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. F2=Double Fuse (208, 240 or 480V only) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit15 L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) Included16, 17 LL=Lamp QD=Quick Disconnect Die-Cast Pendant Mount Box(Specify Single Voltage, Not Compatible with PC3, PHC, C3, MWS, RM or HC) RM=Remote Mount18 W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. 13 TPPH-F2=Thru-Way Pendant Power Hook - 21 Double Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook 21 Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook21 Double Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify Voltage). 22 FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw TWMBS=Thru-Way Mounting Box23 LL=Coated Lamp Included HC=LumaWatt Fixture Control Module (Low19 voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) LAMP TYPE WATTAGE Pulse Start Metal Halide (MP) 175, 200, 250, 320, 350, 400, 450, 750, 1000W Metal Halide (MH) 175, 250, 400, 1000W High Pressure Sodium (HP) 250, 400, 600, 750W HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherewise noted) VOLTAGE CHART MT= Multi-Tap 120/208/240/277V (wired 277V) TT= Triple-Tap 120/277/347V (wired 347V) 5T= 5-Tap 9 120/208/240/277/480V (wired 277V) Specifications and Dimensions subject to change without notice. Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADH082393 01/21/2009 3:22:13 PM PHOTOMETRICS 90 60 2.7 30 3.7 4.9 6.6 CP/1000 MPSG-GR16-M-400 400-Watt MP 42,000-Lumen Coated Lamp* Coefficients Of Utilization Effective floor cavity reflectance rc 80% 70% rw 70 50 30 10 70 50 30 RCR 1 83 78 74 70 77 73 69 2 75 67 61 56 70 63 58 3 68 58 51 46 63 55 49 4 62 52 44 39 58 49 42 5 57 46 38 33 53 43 36 6 52 41 33 28 48 38 31 7 47 36 29 24 44 34 27 8 44 32 25 20 41 31 24 9 40 29 22 18 38 27 21 10 37 26 20 15 35 25 19 Spacing Criterion 1.8 Zone %Lamp Zone 0-30 9.6 0-90 0-40 18.6 90-180 0-60 35.4 Total 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 66 53 43 37 31 26 22 19 17 14 64 55 48 43 38 34 30 27 24 22 56 48 42 38 33 30 26 24 21 19 49 42 36 33 29 26 23 21 19 17 42 33 28 23 20 17 14 12 10 9 61 51 43 37 32 28 24 22 19 17 59 47 39 33 28 24 20 18 15 13 54 45 38 33 29 25 22 19 17 15 52 42 35 30 25 21 18 16 14 12 47 39 33 29 25 22 19 17 15 13 45 37 31 26 22 19 16 14 12 10 %Lamp 55.0 28.9 83.9 Candlepower Degree CP 0 3689 5 3787 15 4330 25 5643 35 6442 45 5212 55 3782 65 2973 75 2697 85 2615 90 2585 95 2542 105 2451 115 2384 125 2235 135 1312 145 1456 155 846 165 627 175 156 180 122 *Coated lamp recommended Specifications and Dimensions subject to change without notice. Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADH082393 01/21/2009 3:22:13 PM DLS Series Single-Phase Central Lighting Inverters Catalog Number Comments FEATURES DLS1500-277-A-20-01 TOTAL WINE & MORE Type AE Application Designed for indoor installation in commercial or industrial applications. Operation When normal utility-supplied power is present, the Synchron central lighting inverter allows utility power to pass through to the connected load and charges the system batteries as required. When utility-supplied power is interrupted, the system will automatically and instantaneously transfer to emergency mode without interruption to connected loads. DC battery-derived emergency power is inverted to AC power and supplied in a pure sine wave output form for 90 minutes (standard run time). A low voltage battery disconnect circuit prevents “deep discharge” damage to the batteries during prolonged power outages. When normal power is restored the system will automatically restart, providing power to connected loads and recharging the batteries. The charging circuit will bring the batteries to full recharge within UL time standards. Construction The Synchron cabinet is constructed of NEMA 1 rated, painted steel. Installation Input power entry point is from the cabinet top. Unit supplied with wall brackets for anchoring and features front service entry. Compliances UL 924 Listed, Emergency Lighting and Power Equipment (standard 90 minute run time) National Electrical Code (NFPA 70) Life Safety Code (NFPA 101) OSHA, state and local codes Made in U.S.A. Warranty Two years full on all components from date of shipment. One year full, 9 years pro-rata for batteries. Ordering Guide DLS - 750 - 120N A 15 03 U Series Synchron Central Lighting Inverter Output Circuit Breaker Voltage Rating Capacity Rating (VA/Watts) (1) Input/Output Voltage (VAC) 400 525 750 1000 1500 2100 120 277 (1) (2) (3) (4) (5) Output Circuit Breaker Quantity 01 to 10 A = 120 VAC B = 277 VAC Output Circuit Breaker Type Blank = Normally On N = Normally Off (3, 4, 5) Output Circuit Breaker Ampere Rating 15 20 25 30 Output Circuit Breakers • 400VA and 525VA models: Supplied standard with one 15 amp normally-on output circuit breaker. • 750VA through 2100VA models: Output circuit breakers are optional. A maximum of 6 monitored or 10 unmonitored normally-on circuit breakers may be specified. A maximum of 4 normally-off circuit breakers may be specified. Maximum rating of normally-off circuit breakers is 20 amperes. Normally-off output circuit breakers include a built-in, 15-minute retransfer delay to accommodate HID lighting loads. Output Circuit Breaker Supervision Blank = Monitored (2) U = Unmonitored DLS Series Single-Phase Central Lighting Inverters Specifications VA/Watts 400 525 750 1000 1500 2100 15/15A 20/15A 25/15A 72 72 96 Power Factor Range .8 lead to .75 lag Input/Output Voltage 120/120 or 277/277VAC ±10% AC Input Circuit Breaker Rating 120/277V 10/15 Amps Charger Size System DC Voltage 2 Amps 36 36 72 Cabinet Size 22”W x 23”H x 10”D (55.9cmW x 58.4cmH x 25.4cmD) BTU/Hour - Line/Inverter 70/260 92/341 131/382 175/510 263/765 368/886 143 (65.1) 173 (78.8) 281 (128) 346 (157.6) 400 (182.2) 480 (218.7) Battery/Charging System Charging System: Monitored – 3-step temperature compensated float Battery Circuit Breaker: Sized to system rating Battery: Type S – Sealed Lead Calcium Expected Normal Life: 10 years at 25°C (77°F) Operating Temperature Range: 20°C to 30°C (68°F to 86°F) Dimensions 400VA to 525VA Models (can be wall mounted) 23” 750VA to 2100VA Models (floor mount only) 36.5” ” 22 ” 32 ” ” 12 Electronics System Short Circuit Rating: 18K AIC, RMS symmetrical Input Power Connection: Terminal block Input Circuit Breaker: Sized to system rating Power Factor: Unity 1.0 (VA = KVA) Power Consumption: Offline, 98% efficient Inverter Design: Pulse width modulation via IGBT circuitry Input Frequency: 60 Hz, ±3% Synchronizing Slew Rate: 1 Hz per second, nominal Transfer Time: "No break" switching; instantaneous Output Wave Shape: True AC sine wave Output Frequency: Normal: synchronized to utility; Inverter: +0.05 Hz Output Circuit Breakers: Single Pole; See "Ordering Guide" Output Regulation: (static) +10%, -5%, based on a 5% to 100% resistive load Output Distortion: Less than 5% THD (linear load) Overload Rating: 115% momentary Overload/Short Circuit Protection: Circuit breakers, output fuse AC Lockout: Prevents battery discharge following installation when AC power is not present Compatibility: Magnetic and electronic ballasts; incandescent, LED, fluorescent, compact fluorescent and HID lamps Time Delay Retransfer: Supplied with “normally off” optional circuit breakers. Holds the unit in emergency mode for 15 minutes after normal AC power is restored, allowing utility power to stabilize and voltage sensitive lighting to resume normal operation. Low Voltage Battery Disconnect: Protects the batteries from damaging “deep discharge” conditions during prolonged power outages Test Means: "Push-to-test" button provided Indicators: Visual LED indicators, audible alarm system Interior Relative Humidity: 95% non-condensing 10 Weight [lbs. (kg) - including batteries] 32”W x 36.5”H x 12”D (81.3cmW x 92.7cmH x 30.5cmD) Dual-Lite • www.dual-lite.com A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America. Copyright © Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A. 0603407 B 6/09 COOPER LIGHTING - METALUX ® DESCRIPTION The accordTM redefines fluorescent lighting by improving on aesthetics, comfort and energy savings. The accordTM provides the right amount of light while eliminating surface shadows commonly found in parabolics. Therefore, accordTM increases the comfort level while providing significant energy savings. Type Catalog # FIXTURE CE-2AC-232T8-UNV-EB81-EL (WITH EMERGENCY BALLAST IN Project FIXTURE) Date Comments The accord is the ideal solution for offices, schools, hospitals, retail and other applications. TM Prepared by SPECIFICATION FEATURES A…Construction C…Ballast Access F…Shielding Shallow 3-1/4" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. KOs for continuous row wiring. Large access plate for supply connection. Ballast can be removed from below without tools. Positively retained frosted acrylic profile lenses provide a soft but effective distribution of light. B…Electrical* E…Ref lector s Ballasts are Class “P” and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations. Reflector has high reflectance baked matte white enamel finish for luminous uniformity. D…Finish Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition. G…Air Return Optional Air Return model provides air flow through air slots in the housing. 2AC 232T8 T8 LAMPS 2' x 4' Recessed Tr o f f e r S e r i e s B A D C E F 3-1/4" [83mm] 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA Access Plate 11-3/4" [298mm] 1-1/2" [204mm] 3-1/4" [83mm] ENERGY DATA 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps @ 277V 232 (58) 23-3/4" [603mm] Luminaire Efficacy Rating LER =FL83 LPW Catalog Number: 2AC-232 48" [1219mm] 8" [204mm] 4-13/16" [123mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.89 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory CEILING COMPATIBILITY G Grid/Lay-in Standard COOPER LIGHTING F Drywall Frame Kit Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange G G or T G or T *** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF080359 2AC PHOTOMETRICS 2AC-232-UNV-EB81 Electronic Ballast (2) F32T8/835 Lamps 3100 Lumens each Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 85% Test Report: 241P14200 Candlepower Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 LER = FL83 LPW Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.89 Along II 1614 1607 1587 1551 1502 1440 1366 1280 1184 1080 967 848 723 589 452 315 187 81 0 Across ⊥ 1614 1618 1605 1587 1558 1521 1477 1425 1366 1298 1221 1134 1022 857 664 465 277 113 0 45° 1614 1612 1596 1569 1531 1483 1425 1358 1282 1198 1107 1007 899 783 635 456 280 118 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 92 83 75 69 63 58 54 50 46 44 101 87 75 66 58 51 46 42 38 35 32 101 83 69 58 50 43 38 34 30 28 25 101 80 64 53 44 38 33 29 25 23 21 99 89 81 73 67 61 56 52 48 45 42 99 85 74 64 57 50 45 41 37 34 32 99 82 68 58 49 43 38 34 30 27 25 99 79 63 52 44 37 32 28 25 23 20 20% 50% 50 30 10 30% 50 30 10 50 94 82 71 62 55 49 44 40 36 33 31 90 78 68 59 53 47 42 38 35 32 30 87 75 65 57 51 45 41 37 34 31 29 94 79 66 56 48 42 37 33 30 27 25 94 76 62 51 43 37 32 28 25 22 20 90 76 64 54 47 41 36 32 29 27 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1280 2129 3945 5271 5271 %Lamp 20.6 34.3 63.6 85.0 85.0 %Fixture 24.3 40.4 74.9 100.0 100.0 Average 0-Deg cd/sm 2188 2118 1996 1743 1331 90 74 60 50 42 36 32 28 25 22 20 10% 30 10 87 73 62 53 46 40 36 32 29 26 24 Average 45-Deg cd/sm 2427 2515 2654 2524 1939 0% 0 87 72 59 49 42 36 31 28 25 22 20 85 70 57 47 40 34 30 26 23 21 19 Average 90-Deg cd/sm 2630 2832 2905 2574 1857 ORDERING INFORMATION SAMPLE NUMBER: 2AC-232-UNV-EB82-U Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width 2=2' Width Series AC=Accord Series Type A=Air (optional) (1) Number of Lamps (Not included) 2=2 Lamp Wattage (Length) 32=32W T8 (48") Shielding Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert Voltage (1) UNV=Universal Voltage 120-277 Lamps L8835=T8 Lamp, 17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed NOTES: Products also available in non-US voltages and frequencies for international markets. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging U=Unit Pack PALC=Job Pack, in carton HPT8 Ballast Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 ACCESSORIES T3A END E.Q. BRACKET PARTS BAG SHIPPING INFORMATION Catalog No. Wt. 2AC-232 28 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 6/10 ADF080359 COOPER LIGHTING - METALUX DESCRIPTION The VT2 Series is an energy efficient industrial Vaportite fixture that features rugged and durable construction. The VT2 incorporates a full metal fixture liner inside a reinforced fiberglass housing with a high impact diffuser. This Vaportite series is suitable for interior and exterior applications and can be surface or chain mounted. Type Catalog # Project FIXTURE DE-VT232-DREMERGENCY (WITH Comments EMERGENCY BALLAST IN FIXTURE) Prepared by The VT2 Series has been designed for maximum operation in commercial institutional and industrial environments where weathering, high temperature, humidity and dust or corrosive fumes are present. ® Date SPECIFICATION FEATURES A ... Construction Fiberglass housing is reinforced polyester and self-extinguishing (ASTM-D635-74) plastic of a permanent pearl gray color. Top of housing has nine embossments (4' unit) and thirteen embossments (8' unit), providing mounting flexibility on uneven surfaces. A watertight hub for 1/2" conduit entry is provided at each end of housing (standard) for continuous feed. Polyurethane gasketing is formed in the housing providing a continuous seamless seal for the diffuser. Six sturdy cam latches (4' unit) and twelve (8' and tandem unit) clamp diffuser tightly for a positive seal between housing, gasketing and diffuser. B ... Electrical* Unit has full metal liner (channel) secured by brass internal/external mounting studs for positive grounding, maximum protection and rigidity. Ballasts are CBM/ETL Class "P" certified suitable to plus 50°F. Spring loaded lampholders. Electrical components and fixtures are UL/CUL listed for Wet Locations.** IP65 approved (4' only). C ... Lens "DR" - Clear low brightness pattern acrylic with 15% high impact additive. "DR-100" - Clear low brightness pattern acrylic with 100% high impact additive. Example: VT2-296DR-100 "LEX" - High impact clear low brightness pattern polycarbonate. LEXAN Example: VT2-296LEX. VT2 132 232 332 154T5 254T5 D ... Reflectors Optional die formed finished or 95% specular miro reflector. A B C 5-7/8" [149mm] 4' OR 8' INDUSTRIAL 1, 2 OR 3 LAMP T8 1 OR 2 LAMP T5HO 7" [178mm] LAMP CONFIGURATIONS MOUNTING DATA 2-lamp 1-lamp Z 5" [127mm] X Y 6-5/8" [168mm] 7" [178mm] W=2-5/8" [67mm] X=2-1/8" [54mm] 3-lamp (T8 Only) Z 5" [127mm] X Y Z 5" [127mm] X W 6-5/8" [168mm] 7" [178mm] Y=3-3/16" [81mm] 41-1/2" [1054mm] Optional Back Hub Locations Y 38-3/4" [984mm] 1/4" x 28" Stud (2 Places) W 6-5/8" [168mm] 7" [178mm] E N E R G Y D ATA 6-5/8" [168mm] Input Watts: X=5-3/8" [137mm] Y=5-3/8" [102mm] Z=1-1/2" [38mm] Vaportight Industrial Y X EB Ballast & T5HO Lamps 254T5 (121), 8T254T5 (242) 49-13/16" [1265mm] EB Ballast & T5HO Lamps 154T5 (62), 254T5 (117) 89-1/2" [2273mm] Optional Back Hub Locations EB Plus Ballast & STD Lamps 132 (46), 232 (73), 332 (108) 87-1/16" [2211mm] 1/4" x 28" Stud (4 Places) Luminaire Efficacy Rating LER = FI-73 Catalog Number: VT-232DR 6-5/8" [168mm] X=5-3/8" [137mm] Y=5-3/8" [102mm] 40-13/16" [1037mm] X 5-1/8" [130mm] 97-13/16" [2484mm] EB Ballast & STD Lamps 132 (36), 232 (57), 332 (82) 40-13/16" [1037mm] Y INSTALLATION DATA Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Not Suitable for Wet Locations if EL4 Option is added. Consult Pre Sales Technical Support. MOUNTING BRACKETS Furnished Two per 2' and 4' Unit Four per 8' Unit OPTIONAL CHAIN HANGING SET (VT2-CHAIN/SET-U) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks Order One (1) Kit for each 2' or 4' Fixture Two (2) Kits Recommended For 8' Fixture Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. Safe and convenient means of disconnecting power ADF071394 09/29/2008 10:06:07 AM PHOTOMETRICS VT2 VT2-254DR-UNVEB81-WL-M4-U Electronic Ballast (2) F54/T5/835 Lamps 4460 Lumens each ? Spacing criterion: (II) 1.2 x mounting height, (? ) 1.6 x mounting height || Efficiency 74.3% Test Report: 127P111 LER = FI57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.24 Along II 1615 1613 1592 1556 1504 1438 1357 1262 1154 1033 902 762 621 485 362 253 158 74 26 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Across ? 1615 1648 1723 1781 1820 1839 1815 1743 1635 1499 1355 1180 994 968 1051 992 827 647 463 45° 1615 1632 1673 1704 1717 1712 1683 1625 1532 1412 1263 1101 944 775 667 677 612 455 297 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 87 73 63 55 48 43 39 35 32 29 27 87 70 57 48 41 36 32 28 25 23 21 87 66 52 43 36 31 27 23 21 18 17 85 75 68 61 56 51 47 44 41 38 36 85 71 61 53 47 42 38 34 31 28 26 85 68 56 47 40 35 31 28 25 22 20 85 65 51 42 35 30 26 23 20 18 16 50% 50 30 10 30% 50 30 10 50 80 67 58 51 45 40 36 32 30 27 25 76 64 55 48 42 38 34 31 28 26 24 72 60 52 45 40 36 33 30 27 25 23 80 64 53 45 39 34 30 27 24 22 20 80 62 50 41 34 30 26 23 20 18 16 76 61 51 43 38 33 29 26 23 21 19 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp 15.8 26.9 49.1 70.3 74.2 Along II 1036 1036 1023 1000 968 926 876 817 750 674 591 501 408 317 233 160 97 45 16 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Spacing criterion: (II) 1.3 x mounting height, (? ) 1.6 x mounting height || Efficiency 81.7% Test Report: 127P113 LER = FI71 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.39 20% Zonal Lumen Summary Lumens 1411 2397 4380 6268 6614 ? Candlepower Across ? 1036 1077 1175 1275 1344 1352 1284 1182 1070 946 833 780 785 816 755 624 518 434 353 45° 1036 1059 1114 1175 1227 1255 1245 1184 1080 961 834 706 597 533 520 489 396 302 224 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 87 78 70 64 58 53 49 45 42 39 37 VT2-232DR-UNVEB81-WL-M4-U Electronic Ballast (2) T8 Lamps 2850 Lumens each Candlepower %Fixture 21.3 36.2 66.2 94.8 100.0 Average 0-Deg cd/sm 7779 7074 6110 5205 4251 76 59 48 40 34 29 25 22 20 18 16 10% 30 10 72 59 49 42 36 32 28 25 23 21 19 72 57 46 39 33 28 25 22 19 17 16 Average 45-Deg cd/sm 10632 10221 9764 13928 27797 0% 0 70 55 44 37 31 26 23 20 18 16 14 Average 90-Deg cd/sm 11288 10954 12196 20408 39527 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 96 86 77 70 64 58 54 50 46 43 40 96 81 69 60 53 47 42 38 35 32 29 96 77 63 53 45 39 35 31 28 25 23 96 73 58 47 40 34 29 26 23 20 18 93 83 74 67 61 56 52 48 45 42 39 93 78 67 59 52 46 41 37 34 31 29 93 74 61 52 44 39 34 30 27 25 22 93 71 57 46 39 33 29 25 22 20 18 20% 50% 50 30 10 30% 50 30 10 50 87 74 63 55 49 44 39 35 32 30 27 82 69 60 52 46 41 37 34 31 28 26 78 65 56 49 44 39 35 32 29 27 25 87 70 58 49 43 37 33 29 26 24 22 87 68 54 45 38 32 28 25 22 20 18 82 67 56 47 41 36 32 28 25 23 21 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 985 1675 2999 4316 4658 %Lamp 17.3 29.4 52.6 75.7 81.7 %Fixture 21.1 36.0 64.4 92.7 100.0 Average 0-Deg cd/sm 4874 4392 3669 2853 1868 82 64 52 43 37 31 27 24 21 19 17 10% 30 10 78 63 53 45 39 34 30 27 25 22 20 78 61 50 42 35 31 27 24 21 19 17 Average 45-Deg cd/sm 6095 5171 4791 5921 5874 0% 0 76 59 48 40 33 29 25 22 19 17 15 Average 90-Deg cd/sm 5343 4906 5995 5721 5512 ORDERING INFORMATION S A M P L E N U M B E R : 8 T V T 2 - 2 5 4 D R - U N V- E B 8 2 - M 4 - U Width Blank=4' Length 8T=8' Length Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt UNV=Universal Voltage 120/277V UNC=Universal Voltage 347/480V (T5 Linear Only) Series VT2=Vapor-Tite Number of Lamps (3) 1=1 lamp (T5 or T8) 2=2 lamps (T5 or T8) 3=3 lamps (T8 only) Fusing GL=Single Element Fuse GM=Double Element Fuse Emergency=EM Installed, see EM options table (3) (4) (Lamps not included) Lamp Type 32=32W T8 Lamp (4' Long) 54T5=54W T5HO Lamp (4' Long) Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-100%=100% High Impact Additive LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern (1) WL=Wet Location Ballast Type (1) Label T8 Systems EB8 =T8 Electronic Instant Start.(4) Total Harmonic Distortion < 20% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 10% Ballast 1 or 2 EB8 /L= T8 Electronic Instant Start w/0.80 Ballast Factor. No. of Ballast 1 or 2 T5 Systems EBT =T5HO Electronic Program Start. (2) NOTES: Ballast type used only if ballast & voltage is chosen Not available when specify(3) ing emergencies, voltage must be specific. T5HO is only available in 1 or 2-lamp versions (4) only. Emergency option in 3 lamp version must use remote mount test switch. No. of Ballast 1 or 2 Packaging Options U=Unit Pack RIF1=Radio Interference Suppressor PALC=Job Pack in Carton TH=(2) Top Watertite Hubs TEH=(2) Top & (2) End Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry) TILW=Tandem In-Line Wiring Option (Consult TILW Option Catalog Page) PI/CPI=Plug-In Option DD=Deep Diffuser (4' Length) (Available for 4' Fixture Length) To Complement Deep Diffuser Depth of 8' Fixture M4=Specular Reflector SSL=Stainless Steel Latches ACCESSORIES Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks Order One (1) Kit for each 2' or 4' Fixture Two (2) Kits Recommended For 8' Fixture VT2-SS-MBK=Stainless Steel Mounting Bracket SHIPPING DATA Catalog No. VT2-132DR-WL VT2-232DR-WL Specifications and Dimensions subject to change without notice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 Wt. 35 lbs. 35 lbs. ADF071394 09/29/2008 10:06:07 AM COOPER LIGHTING - METALUX ® DESCRIPTION The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems. The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. Type Catalog # Project FIXTURE OE-2GR8-232-UNVEB81-EL (EMERGENCY Comments BALLAST IN FIXTURE) Date Prepared by SPECIFICATION FEATURES Construction Electrical** Hinging/Latching Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and unibody endplate for added strength. Ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor-lock lampholders. UL/CUL listed. Suitable for damp locations. Positive spring loaded steel latches and safety lock T-hinges provide secure, high quality door fit and allow hinging and latching from either side. Finish Frame/Shielding Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency. Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full width mechanical light traps. Light stabilized, acrylic prismatic lens. 2GR8 228T8 232 428T8 432 2' X 4' TROFFER 2 OR 4 LAMP General Purpose T8 Commercial Troffer 3-1/4" [83mm] ENERGY DATA Input Watts: EB Ballast & STD Lamps 228T8 (49), 232 (61) 428T8 (98), 432 (122) 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA 2 LAMP Location of Standard Access Opening Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93 3-1/4" [83mm] 1-1/2" [38mm] 1-1/2" [38mm] 10-3/4" [274mm] 23-3/4" [603mm] 23-3/4" [603mm] 3-1/4" [83mm] 3-1/8" [80mm] 47-15/16" [1218mm] Catalog Number: 2GR8-432A LER = FL-76 4 LAMP 1" [26mm] 3-1/2" [89mm] Luminaire Efficacy Rating LER = FL-82 Catalog Number: 2GR8-232A X=4-3/16" [107mm] Y=4-3/4" [121mm] X Y Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.16 X 23-3/4" [603mm] *Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory. DOOR FRAMES 2GR8 Flat, White Steel (White Latches) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T COOPER LIGHTING G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G G*** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF012707 2GR8 PHOTOMETRICS 2GR8-232A Electronic Ballast (2) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 79.4% Test Report: 2GR8-232A.IES LER = FL-82 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1851 1855 1830 1790 1731 1653 1554 1434 1297 1127 922 731 570 430 316 224 162 87 0 Across ⊥ 1851 1851 1845 1834 1813 1776 1720 1650 1551 1400 1182 924 675 476 343 262 198 114 0 45° 1851 1846 1830 1806 1768 1714 1643 1551 1424 1251 1060 851 619 413 261 179 142 89 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 95 83 73 65 58 52 47 43 39 36 33 95 80 68 59 51 45 40 36 32 29 27 95 77 64 54 46 40 35 31 28 25 23 92 85 77 71 65 60 56 52 48 45 42 92 82 72 64 57 51 46 42 38 35 33 92 79 67 58 51 45 40 36 32 29 27 92 76 63 53 46 40 35 31 28 25 23 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 88 78 69 61 55 49 45 41 37 34 32 84 75 66 59 53 48 43 40 36 33 31 81 72 64 57 51 46 42 39 35 33 30 79 68 57 49 42 37 32 29 26 23 21 88 76 65 56 49 44 39 35 32 29 26 88 74 62 52 45 39 35 31 28 25 23 84 73 63 55 48 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1476 2440 4149 4924 4924 %Lamp 23.8 39.4 66.9 79.4 79.4 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3662 3664 3613 3531 3413 3260 3067 2829 2538 2188 1816 1457 1138 859 626 447 314 172 14 Across ⊥ 3662 3657 3640 3610 3555 3461 3327 3155 2918 2591 2176 1729 1304 950 687 517 380 214 47 45° 3662 3647 3614 3560 3480 3365 3206 2998 2723 2383 2023 1630 1212 827 530 359 272 167 33 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 87 80 73 67 62 57 53 49 46 43 2GR8-432A Electronic Ballast (4) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 77.1% Test Report: 2GR8-432A.IES LER = FL-76 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.16 Candela %Fixture 30.0 49.6 84.3 100.0 100.0 Average 0-Deg cd/sm 2556 2044 1632 1388 1601 84 71 60 52 45 39 34 31 27 25 22 81 71 61 54 47 42 38 34 31 28 26 81 69 59 51 44 38 34 30 27 25 22 Average 45-Deg cd/sm 2838 2380 1567 1109 1638 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Average 90-Deg cd/sm 3176 2594 1807 1624 2098 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 92 84 77 71 65 60 56 52 48 45 42 92 81 71 63 56 50 46 41 38 35 32 92 78 66 57 50 44 39 35 31 29 26 92 75 62 52 45 39 34 30 27 24 22 90 82 75 69 63 58 54 50 47 44 41 90 90 79 76 70 65 62 56 55 49 50 43 45 39 41 35 37 31 34 28 32 26 90 74 61 52 44 39 34 30 27 24 22 20% 50% 50 30 10 30% 50 30 10 50 86 76 67 60 53 48 43 40 36 33 31 82 73 65 57 52 46 42 39 35 33 30 79 70 62 56 50 45 41 37 34 32 30 86 74 63 55 48 42 38 34 31 28 26 86 71 60 51 44 38 34 30 27 24 22 82 71 61 53 47 42 37 33 30 28 25 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2902 4769 8035 9566 9566 %Lamp 23.4 38.5 64.8 77.1 77.1 %Fixture 30.3 49.9 84.0 100.0 100.0 82 69 59 50 43 38 33 30 27 24 22 Average 0-Deg cd/sm 4963 4074 3260 2770 3165 Average 45-Deg cd/sm 5406 4558 3139 2225 3073 10% 30 10 79 69 60 52 46 41 37 33 30 27 25 0% 0 79 67 57 49 43 37 33 30 27 24 22 77 66 56 48 41 36 32 28 25 23 21 Average 90-Deg cd/sm 5877 4835 3606 3204 3938 ORDERING INFORMATION SAMPLE NUMBER: 2GR8-232A-UNV-EB81-U Rating (4) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) Series R8=General Purpose T8 Commercial Troffer (1) (1) Number of Lamps 2=2 Lamps 4=4 Lamps Options FR=Fire Label Voltage (2) 347V=347 Volt UNV=Universal Voltage 120-277 (3) (Not included) Wattage 28T8=28W T8 (48") 32=32W T8 (48") Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") Packaging U=Unit Pack Ballast Type (2) ACCESSORIES EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) No. of Ballast FCTKA-24W-U=Field Installed Flange Kit 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast N=Natural Trim Kit 22=2' x 2' 1 or 2 Field W=White 24=2' x 4' ER8 = T8 Electronic Program Rapid Start. Convertible Total Harmonic Distortion < 10% U=Unit Pack Blank=Single No. of Ballast Aluminum R=In Row 1 or 2 E=End Row High Performance T8 Ballast (HPT8) HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed FCTK Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and (3) (4) frequencies for international markets. Not available when specifying emergencies, voltage must be specific. For NYC rated product, see separate specification sheets. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. A – 24 R W – U SHIPPING INFORMATION Catalog No. Wt. 2GR8-228T8A 2GR8-232A 2GR8-428T8A 2GR8-432A 20 lbs. 20 lbs. 20 lbs. 20 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/11 ADF012707 CORELITE DESCRIPTION Corelite's Minigator suspended direct-indirect fluorescent luminaire features a rugged aluminum construction, petite profile, elegant styling, cross blade louver and optional adjustable uplight and downlight optics for evolving interior spaces. Our Slide-N-Lock TM optics accessory allows the designer to adjust the amount of uplight and downlight for a particular application. The Minigator may be mounted individually or continuously with 4', 8' and 12' modular sections. Luminaires align with T-Grid and interface with all ceiling types. The Minigator is suited for open offices, private offices, conference rooms, reception areas and educational facilities. Type Catalog # Project FIXTURE SE-MB-132-TB-UNV-EB81-E Date BALLAST IN FIXTURE) Prepared by Comments (WITH EMERGENCY SPECIFICATION FEATURES A ... Construction Housing is 6063 T5 aluminum extrusion forming a 6-3/4" x 2-1/2" rounded profile. Standard 4'-0", 8'-0" and 12'-0" fixture lengths combine for continuous runs. D ... Reflectors Reflector pan is painted with a high reflectance white powder coat finish. Optional die-formed side reflectors are highly specular anodized aluminum. B ... End Caps Standard end caps are precision die-cast aluminum, mechanically attached without exposed fasteners. E ... Electrical T5/T5HO fixtures are pre-wired with quick wire connectors and use UL listed Class P, T5/T5HO program rapid start universal voltage electronic ballasts, power factor of 97% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards. C ... Louver A continuous semi-specular aluminum parabolic 1-1/4" blades spaced 2-1/4" on-center with a 2-3/4" opening. A C E D F ... Finish Fixture housings are standard white using electrostatically applied polyester powder coat paint. Mounting Standard aircraft cable mounts on 4'-0", 8'-0" and 12'-0" centers. Refer to installation section for various ceiling interface details and rigid pendant mounting details. Minigator Cross Blade Parabolic Louver B F 1T5 1T5HO Suspended Direct/Indirect 2-1/2" [64mm] Light Distribution Indirect - 74.0% Direct - 26.0% 6-3/4" [171mm] MO DUL E S AND 1/2" [14mm] E nd DIME NS IO NS * Cap S ide View 48" [1219mm] 96" [2438mm] 144" [3658mm] *Dimens ions do not include end caps . ORDERING INFORMATION Sample Number: MB-WB-1T5-1C-UNV-AC48-T1-12 Series MB=Minigator Suspended Number of Lamps 1=1 Lamp Number of Circuits 1=1 Circuit Optics Up S=Specular Lamp Type N5=T5 Normal Output Wiring 1 B=Battery Pack W=White T5=T5 High Output C=Standard Circuit D=Dimming Optics Down B=Cross Blade Louver 1 E=Emergency T=Nightlight Y=Daylight Notes: 1 2 Not all options available. Please consult your Cooper Lighting Representative for availability. Specifications and dimensions subject to change without notice. Consult adder section of the price guide for additional standard lengths. Voltage 1 120=120V 277=277V 347=347V UNV=Universal (120V277V) Suspension A=Aircraft Cable Suspension Length Adjustable Cable 48", 120", 240", 300", or 360" (infinite adjustment along entire length of cable) Rigid Pendant 2 12", 15", 18", 21", 24", or 27" P=Rigid Pendant Power Feed 1 C=Straight Cord K=Curly Cord P=Rigid Pendant Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. Ceiling Type T1=1" T-Bar Options T9=9/16" T-Bar TS=Slotted T-Bar DL1 ST=Structure JB=4" Octagonal J-Box DL3 Slide-N-Lock™ DL2 DL4 DL5 DL6 Run Length Individually Mounted Luminaires may be 4', 8', or 12' in length DL7 DL8 Continuously Mounted Standard row configurations over 12' consist of 8' and 12' sections ADE032183 08/14/2009 3:20:50 PM PHOTOMETRICS Corelite C o e f f i c i e n ts C andela E ffec tive floor c avity reflec tanc e 80% 70% rc rw RCR MB -S B -1T 5 (1) F P 54/841/HO 4500 Lumens o f U ti l i z a ti o n 20% 50% 30% 10% 0% A ngle 0 A long II 500 o 45 500 A c ros s I 500 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 5 15 494 461 497 491 499 529 0 1 92 85 92 81 92 78 92 75 82 76 82 73 82 70 82 67 64 57 64 55 64 54 47 42 47 41 47 40 31 28 31 28 31 28 24 21 25 35 410 339 501 580 708 534 2 3 4 5 78 71 66 60 72 64 57 50 67 58 50 44 63 53 46 39 69 64 59 54 64 57 51 46 60 52 46 40 57 49 42 36 51 45 41 37 48 42 37 33 45 39 34 29 38 34 31 28 36 32 28 25 35 30 27 23 26 24 22 20 25 23 20 18 24 22 19 17 19 17 15 14 45 55 65 75 249 125 27 11 294 68 33 13 114 70 59 17 6 7 8 9 56 51 47 44 46 41 37 33 39 34 30 27 34 30 26 23 50 46 42 39 41 37 33 30 35 31 28 25 31 27 24 21 33 30 27 24 29 26 23 20 26 23 20 17 25 23 21 19 23 20 18 16 21 18 16 14 18 17 15 14 17 15 13 12 15 14 12 11 12 11 10 09 85 90 95 105 3 0 17 88 5 0 142 535 7 0 123 580 10 41 30 24 20 36 28 22 19 22 18 15 17 14 12 12 11 09 08 115 189 600 932 125 135 298 396 545 605 835 707 145 155 165 175 180 483 550 597 621 623 630 646 642 628 623 715 695 662 624 623 E fficiency 90.9% T es t R eport #LS I17896 Zonal L umen S ummary L u m i n a n c e D a ta Zone 0-30 0-40 0-60 L umens 434 730 1006 %L amp 9.65 16.24 22.36 %F ixture 10.62 17.87 24.60 A ngle 0-Deg in Deg 45 55 c d/s m 4810 2974 45-Deg c d/s m 5677 1633 90-Deg c d/s m 2211 1683 0-90 40-90 60-90 1064 333 58 23.66 7.42 1.30 26.03 8.17 1.43 65 75 85 889 579 578 1070 694 844 1920 900 1250 90-180 0-180 3025 4089 67.23 90.89 73.97 100.00 COMMON CIRCUIT CONFIGURATIONS FOR TWO LAMP SUSPENDED FIXTURE 1C =S ingle circuit luminaire 1E =S ingle circuit luminaire with emergency circuit 1C 1B =S ingle circuit luminaire with battery pack 48"(1219mm) =C ircuit 1 =E mergency C ircuit 1E =B attery C ircuit 96"(2438mm) =P ower Mount 1B =Non-P ower Mount 144"(3658mm) STANDARD ROW CONFIGURATIONS F IXT UR E L E NG T H 4' 4' 1 8' 12' 8' 12' 16' 20' 24' 28' 32' 36' 40' 44' 48' 1 2 1 1 1 2 2 1 1 2 3 2 1 2 3 4 52' 56' 60' 64' 68' 2 1 3 4 5 2 1 4 5 72' 76' 80' 84' 88' 92' 96' 100' 104' 108' 6 2 1 5 6 7 Specifications and Dimensions subject to change without notice. Corelite • 4675 A Holly Street • Denver, CO 80216 • 303.393.1522 • FAX 303.393.1477 2 1 6 7 8 2 1 7 8 9 ADE032183 08/14/2009 3:20:50 PM C orelite's lates t innovation, S lide-N-Lock T M optics revolutionizes the concept of variable uplight and downlight percentages within a direct-indirect fluores cent luminaire. S lide-N-Lock T M optics cons is ts of two s liding parts des igned to provide combinations of uplight and downlight in approximately 5% increments . T he uplight range begins at approximately 5% (fully clos ed) and ends at approximately 40% (fully open). T he optics will be factory s et to the s pecified s etting, although it can be field adjus ted. T o adjus t, s imply depres s the control notch, then "s lide-n-lock" the optic into the des ired s etting. T he S lide-N-Lock T M optics s imply s lides in and out of the top of the Minigator hous ing for eas y lamp maintenance. (P atent P ending) MB -S B -1T 5-DL -1 MB -S B -1T 5-DL -2 R eport # F T L89083 Direct - 95.3% Indirect - 4.7% E fficiency 59.2% R eport # F T L89082 Direct - 93.4% Indirect - 6.6% E fficiency 59.8% MB -S B -1T 5-DL -3 MB -S B -1T 5-DL -4 R eport # F T L89081 Direct - 90.1% Indirect - 9.9% E fficiency 60.8% R eport # F T L89080 Direct - 85.0% Indirect - 15.0% E fficiency 62.3% MB -S B -1T 5-DL -5 MB -S B -1T 5-DL -6 R eport # F T L89079 Direct - 80.5% Indirect - 19.5% E fficiency 63.9% R eport # F T L89078 Direct - 75.7% Indirect - 24.3% E fficiency 65.7% MB -S B -1T 5-DL -7 MB -S B -1T 5-DL -8 R eport # F T L89077 Direct - 69.9% Indirect - 30.1% E fficiency 67.9% R eport # F T L89076 Direct - 64.1% Indirect - 35.9% E fficiency 70.4% Specifications and Dimensions subject to change without notice. Corelite • 4675 A Holly Street • Denver, CO 80216 • 303.393.1522 • FAX 303.393.1477 ADE032183 08/14/2009 3:20:50 PM