COOPER LIGHTING - LUMARK®

advertisement
COOPER LIGHTING - LUMARK
DESCRIPTION
The Steeler SG Prismatic Glass Series combines the popular Steeler ballast
housing with shock- and impact-resistant prismatic borosilicate glass
reflectors for maximum durability and photometric performance. U.L. listed
and labeled for damp location. CSA Certified.
®
Type
Catalog #
Project
Date
The Steeler SG is perfect for manufacturing and assembly areas, retail
stores, wholesale warehouses, grocery chains, malls and auto service areas,
where up light is desired.
FIXTURE
AE IS THIS A FIXTURE
Comments
BUT FED BY A CIRCUIT WITH AN
Prepared by
INVERTER. SEE INVERTER CUT
SHEET ATTACHED.
SPECIFICATION FEATURES
A ... Mounting
Easy slide-on die-cast aluminum
mounting box with tapped opening
for 3/4" conduit.
B ... Housing
Heavy-duty, formed steel housing
with an open air ballast for cooler
operation is finished in a white
polyester powder coat.
C ... Safety Cable
Safety cable attached from
housing to reflector standard.
F ... Socket
Mogul-base porcelain socket.
D ... Universal Brackets
Universal ladder brackets allow for
the flexibility to change out with
other reflectors available in acrylic
or aluminum.
G ... Reflector
Easily mounted prismatic
borosilicate reflector has multiple
adjustable distribution patterns for
precise control. Zinc-plated wire
form with optional safety glass
bottom for durable performance.
E ... Ballast
High power factor ballast with
class H insulation. Minimum
starting temperature is -40°C
(-40°F) for HPS and -30°C (-20°F)
for MH, MP and ML. CSA certified.
SG
16" & 21"
PRISMATIC GLASS
HIGH-BAY
175 - 1000W
A
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
B
PRISMATIC GLASS
HIGH-BAY
INDUSTRIAL LUMINAIRE
C
T E C H N I C A L D AT A
D
16" Reflector
Maximum height is
24 1/2" [622mm]
E
F
21" Reflector
Maximum height is
25 3/4" [654mm]
EISA Compliant
65°C Maximum Ambient Temperature.
90°C Supply Wiring
E N E R G Y D AT A
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
CWA Ballast Input Watts
200W MP HPF (227 Watts)
250W MP HPF (283 Watts)
320W MP HPF (365 Watts)
G
350W MP HPF (400 Watts)
400W MP HPF (452 Watts)
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts)
600W HPS HPF (665 Watts)
750W HPS HPF (850 Watts)
750W MP HPF (820 Watts)
1000W HPS HPF (1100 Watts)
1000W MH HPF (1085 Watts)
1000W MP HPF (1070 Watts)
YS
C
ER
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
T EM
S
51 lbs. (23 kgs.)
D
S H I P P I N G D AT A
Approximate Net Weight:
S
16" [406mm] or
21" [533mm]
TIFIE
ADH082393
01/21/2009 3:22:13 PM
SG 16" & 21" PRISMATIC GLASS HIGH-BAY
ORDERING INFORMATION
Sample Number: MPSG-GR16-M-400-MT-Q
Lamp Type
MP=Pulse Start Metal1
Halide
Reflector Type
GR=Glass Reflector
MH=Metal Halide1, 2
HP=High Pressure
Sodium
Reflector
Diameter
16=16'' Diameter
ML=Pulse Start MH 1, 3, 4
(Linear Reactor)
21=21'' Diameter
Distribution
C=Concentrated
5
Series
SG=Steeler Glass
M=Medium
W=Wide
Lamp
Wattage
Voltage 7
120V=120V
MP
208V=208V
240V=240V
175=175W
200=200W
250=250W
320=320W
277V=277V
347V=347V
350=350W
400=400W
480V=480V
MT=Multi-Tap, 8
wired 277V
450=450W
750=750W
TT=Triple-Tap, 9
wired 347V
1000=1000W
5T=5-Tap10
MH
2
175=175W
250=250W
400=400W
1000=1000W
HP
250=250W
400=400W
600=600W6
750=750W
Socket
11, 12
OR=Open
Rated
Socket for
Metal
Halide
Lamps
__=Non Applicable
(HPS or Not
compatible with
OR Socket)
Open Rated socket and lamp must be used.
Notes: 1
2
MH available in non-U.S. markets only.
3
175, 200, 250, 320, 350, 400, 450 and 750W only.
4
277V only, not available with HSW, Q, EM, HL or HC options.
5
Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the
nomenclature of the fixture. Otherwise fixture is shipped in medium setting.
6
High Pressure Sodium only.
7
Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper
Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not
available in 347V and TT Voltages.
8
Multi-Tap ballast 120/208/240/277V wired 277V.
9
Triple-Tap ballast 120/277/347V wired 347V.
10
5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant
MP fixtures not available in 5-Tap Voltages.
11
Not applicable for HPS.
12
Required for metal halide lamps up to 750W.
13
Requires FH-1or FL-1or SHK.
14
Requires FL-1 and TPPH.
15
Not available with HL or HC options.
16
Uses coated lamp.
17
Lamp is shipped separately.
18
Not available with QD, W or WL options.
19
Not available with QD, PC3, C3, PHC or MWS. Not available with single circuit MWS special order.
20
Order separately.
21
Requires FL-1 and PHC.
22
Requires FL-1 and PHC-XXXV-NEMA.
23
Specify L/TCB when using thru-way mounting box (TWMBS) accessory.
Options
VI=Visual Indicator system, externally mounted
LED Signal
Accessories 20
C3=3' Cord-No Plug - Requires FH-1, FL-1, or 13
C3=3' Cord with no plug (Specify Voltage)13
PC3=3' Cord with NEMA Plug (120V-L5-15P, 13
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for
6' Cord) Requires FH-1 or FL-1, or
SHK. Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
PC3=3' Cord with NEMA Plug - (120V-L5,
208V-L6-15P, 347V-L37-20P and
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
cord). Requires FH-1 or FL-1, or SHK.
Use with TPPH-NEMA. Specify Voltage.
PHC=Power Cord and Plug (18" Power Cord 14
and Non-NEMA plug configuration.
Must be used with FL-1 and TPPH
(Thru-Way Pendant Power Hook). Must
specify single voltage.
PHC-NEMA=Power Cord and NEMA plug - 18"
Power Cord and 20 Amp NEMA
plug configuration. Must be used
with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power Hook)
PHC-NEMA=Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be
used with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power
Hook).
PS=Protective Starter (Available in 1000W HPS
only. For other wattages consult factory).
P=Pre-set Socket Position from the factory
FH-1=Die-cast Aluminum Fixture Hook (with
3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with
3/4" threads for easy installation)
SHK
PHC=Power Hook Cord and Non-NEMA plug 14
configuration. Must be used with FL-1
and TPPH (Thru-Way Pendant Power
Hook)
SGB16/GR=16" Safety Glass Bottom (Not
Compatible with WG16/GR)
WG16/GR=Wire Guard for 16" Reflector
WG21/GR=Wire Guard for 21" Reflector
WG16/GLC/GR=Gym Wireguard w/ Safety Glass
Bottom for 16" Reflector
WG16/SGB16A=Gym Wire Guard with Safety
Glass Bottom for 16" Refractor
GTWG16=Glass Top Wire Guard
GFWG16/WG16=Glass Full Wire Guard
GTWG21=Glass Top Wire Guard
WG21/GLC/GR=Gym Wireguard w/ Safety Glass
Bottom for 21" Reflector
GFWG21/WG21=Glass Full Wire Guard
SHK=Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
TPPH=Thru-Way Pendant Power Hook. 21
Requires FL-1 and PHC. Specify
Voltage.
SS=Space Saver Feature
F1=Single Fuse (120, 277 or 347V only)
TPPH-F=Thru-Way Pendant Power Hook 21
Single Fuse, 120, 277 or 347 Volt.
Requires FL-1 and PHC. Specify
Voltage.
F2=Double Fuse (208, 240 or 480V only)
SCF=3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative lengths
available. Example: SCF6 = 6' Cable)
Q=Quartz Restrike (Hot Strike Only)
EM=Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
EM/SC=Emergency Separate Circuit15
L/TCB=Less Top Connector Box (Housing
shipped less top connector box.
(Specify when using TWMBS
accessory)
Included16, 17
LL=Lamp
QD=Quick Disconnect Die-Cast Pendant Mount
Box(Specify Single Voltage, Not
Compatible with PC3, PHC, C3, MWS, RM
or HC)
RM=Remote Mount18
W/MWS=MWS Industrial components attached
to the fixture at the factory. (Standard
cord length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS
Modular Wiring System section for
additional information.
13
TPPH-F2=Thru-Way Pendant Power Hook - 21
Double Fused, 208, 240, or 480
Volt. Requires FL-1 and PHC.
Specify Voltage.
TPPH-F-QD=Thru-Way Pendant Power Hook 21
Single Fuse, Quick Disconnect.
Requires FL-1 and PHC. Specify
Voltage (120, 277, or 347V)
TPPH-F2-QD=Thru-Way Pendant Power Hook21
Double Fuse, Quick
Disconnect. Requires FL-1 and
PHC. Specify Voltage (208,
240, or 480V)
TPPH-NEMA=Thru-Way Pendant Power
Hook. Requires FL-1 and
PHC-XXXV-NEMA. (Specify
Voltage).
22
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
TWMBS=Thru-Way Mounting Box23
LL=Coated Lamp Included
HC=LumaWatt Fixture Control Module (Low19
voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit)
LAMP TYPE
WATTAGE
Pulse Start Metal Halide (MP)
175, 200, 250, 320, 350, 400, 450, 750, 1000W
Metal Halide (MH)
175, 250, 400, 1000W
High Pressure Sodium (HP)
250, 400, 600, 750W
HL=LumaWatt Fixture Control Module (Allows
low voltage control wire to be
daisy-chained between fixtures outside AC
conduit run similar to low voltage
intercom's, fire alarms and phone systems)
QLL=Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
VOLTAGE CHART
MT= Multi-Tap
120/208/240/277V (wired 277V)
TT= Triple-Tap
120/277/347V (wired 347V)
5T= 5-Tap
9
120/208/240/277/480V (wired 277V)
Specifications and Dimensions subject to change without notice.
Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADH082393
01/21/2009 3:22:13 PM
PHOTOMETRICS
90
60
2.7
30
3.7
4.9
6.6
CP/1000
MPSG-GR16-M-400
400-Watt MP
42,000-Lumen Coated Lamp*
Coefficients Of Utilization
Effective floor cavity reflectance
rc
80%
70%
rw 70 50 30 10
70 50 30
RCR
1 83 78 74 70
77 73 69
2 75 67 61 56
70 63 58
3 68 58 51 46
63 55 49
4 62 52 44 39
58 49 42
5 57 46 38 33
53 43 36
6 52 41 33 28
48 38 31
7 47 36 29 24
44 34 27
8 44 32 25 20
41 31 24
9 40 29 22 18
38 27 21
10 37 26 20 15
35 25 19
Spacing Criterion
1.8
Zone
%Lamp
Zone
0-30
9.6
0-90
0-40
18.6
90-180
0-60
35.4
Total
10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
66
53
43
37
31
26
22
19
17
14
64
55
48
43
38
34
30
27
24
22
56
48
42
38
33
30
26
24
21
19
49
42
36
33
29
26
23
21
19
17
42
33
28
23
20
17
14
12
10
9
61
51
43
37
32
28
24
22
19
17
59
47
39
33
28
24
20
18
15
13
54
45
38
33
29
25
22
19
17
15
52
42
35
30
25
21
18
16
14
12
47
39
33
29
25
22
19
17
15
13
45
37
31
26
22
19
16
14
12
10
%Lamp
55.0
28.9
83.9
Candlepower
Degree CP
0
3689
5
3787
15
4330
25
5643
35
6442
45
5212
55
3782
65
2973
75
2697
85
2615
90
2585
95
2542
105
2451
115
2384
125
2235
135
1312
145
1456
155
846
165
627
175
156
180
122
*Coated lamp recommended
Specifications and Dimensions subject to change without notice.
Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADH082393
01/21/2009 3:22:13 PM
DLS Series
Single-Phase Central Lighting Inverters
Catalog Number
Comments
FEATURES
DLS1500-277-A-20-01
TOTAL WINE & MORE
Type
AE
Application
Designed for indoor installation in commercial or industrial applications.
Operation
When normal utility-supplied power is present, the Synchron central
lighting inverter allows utility power to pass through to the connected
load and charges the system batteries as required. When utility-supplied
power is interrupted, the system will automatically and instantaneously
transfer to emergency mode without interruption to connected loads. DC
battery-derived emergency power is inverted to AC power and supplied
in a pure sine wave output form for 90 minutes (standard run time).
A low voltage battery disconnect circuit prevents “deep discharge”
damage to the batteries during prolonged power outages. When normal
power is restored the system will automatically restart, providing power
to connected loads and recharging the batteries. The charging circuit
will bring the batteries to full recharge within UL time standards.
Construction
The Synchron cabinet is constructed of NEMA 1 rated, painted steel.
Installation
Input power entry point is from the cabinet top. Unit supplied with wall
brackets for anchoring and features front service entry.
Compliances
UL 924 Listed, Emergency Lighting and Power Equipment
(standard 90 minute run time)
National Electrical Code (NFPA 70)
Life Safety Code (NFPA 101)
OSHA, state and local codes
Made in U.S.A.
Warranty
Two years full on all components from date of shipment.
One year full, 9 years pro-rata for batteries.
Ordering Guide
DLS - 750 - 120N
A
15
03
U
Series
Synchron
Central Lighting
Inverter
Output Circuit
Breaker Voltage
Rating
Capacity Rating
(VA/Watts) (1)
Input/Output
Voltage (VAC)
400
525
750
1000
1500
2100
120
277
(1)
(2)
(3)
(4)
(5)
Output Circuit
Breaker Quantity
01 to 10
A = 120 VAC
B = 277 VAC
Output Circuit
Breaker Type
Blank = Normally On
N = Normally Off (3, 4, 5)
Output Circuit
Breaker Ampere
Rating
15
20
25
30
Output Circuit Breakers
• 400VA and 525VA models: Supplied standard with one 15 amp normally-on output circuit breaker.
• 750VA through 2100VA models: Output circuit breakers are optional.
A maximum of 6 monitored or 10 unmonitored normally-on circuit breakers may be specified.
A maximum of 4 normally-off circuit breakers may be specified.
Maximum rating of normally-off circuit breakers is 20 amperes.
Normally-off output circuit breakers include a built-in, 15-minute retransfer delay to accommodate HID lighting loads.
Output Circuit Breaker
Supervision
Blank = Monitored (2)
U = Unmonitored
DLS Series
Single-Phase Central Lighting Inverters
Specifications
VA/Watts
400
525
750
1000
1500
2100
15/15A
20/15A
25/15A
72
72
96
Power Factor Range
.8 lead to .75 lag
Input/Output Voltage
120/120 or 277/277VAC ±10%
AC Input Circuit Breaker Rating
120/277V
10/15 Amps
Charger Size
System DC Voltage
2 Amps
36
36
72
Cabinet Size
22”W x 23”H x 10”D
(55.9cmW x 58.4cmH x
25.4cmD)
BTU/Hour - Line/Inverter
70/260
92/341
131/382
175/510
263/765
368/886
143 (65.1)
173 (78.8)
281 (128)
346 (157.6)
400 (182.2)
480 (218.7)
Battery/Charging System
Charging System: Monitored – 3-step temperature compensated float
Battery Circuit Breaker: Sized to system rating
Battery: Type S – Sealed Lead Calcium
Expected Normal Life: 10 years at 25°C (77°F)
Operating Temperature Range: 20°C to 30°C (68°F to 86°F)
Dimensions
400VA to 525VA Models
(can be wall mounted)
23”
750VA to 2100VA Models
(floor mount only)
36.5”
”
22
”
32
”
”
12
Electronics
System Short Circuit Rating: 18K AIC, RMS symmetrical
Input Power Connection: Terminal block
Input Circuit Breaker: Sized to system rating
Power Factor: Unity 1.0 (VA = KVA)
Power Consumption: Offline, 98% efficient
Inverter Design: Pulse width modulation via IGBT circuitry
Input Frequency: 60 Hz, ±3%
Synchronizing Slew Rate: 1 Hz per second, nominal
Transfer Time: "No break" switching; instantaneous
Output Wave Shape: True AC sine wave
Output Frequency: Normal: synchronized to utility; Inverter: +0.05 Hz
Output Circuit Breakers: Single Pole; See "Ordering Guide"
Output Regulation: (static) +10%, -5%, based on a 5% to 100%
resistive load
Output Distortion: Less than 5% THD (linear load)
Overload Rating: 115% momentary
Overload/Short Circuit Protection: Circuit breakers, output fuse
AC Lockout: Prevents battery discharge following installation when
AC power is not present
Compatibility: Magnetic and electronic ballasts; incandescent, LED,
fluorescent, compact fluorescent and HID lamps
Time Delay Retransfer: Supplied with “normally off” optional circuit
breakers. Holds the unit in emergency mode for 15 minutes after
normal AC power is restored, allowing utility power to stabilize and
voltage sensitive lighting to resume normal operation.
Low Voltage Battery Disconnect: Protects the batteries from
damaging “deep discharge” conditions during prolonged power
outages
Test Means: "Push-to-test" button provided
Indicators: Visual LED indicators, audible alarm system
Interior Relative Humidity: 95% non-condensing
10
Weight [lbs. (kg) - including batteries]
32”W x 36.5”H x 12”D
(81.3cmW x 92.7cmH x 30.5cmD)
Dual-Lite • www.dual-lite.com
A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America.
Copyright © Hubbell Lighting, Inc., All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A.
0603407 B 6/09
COOPER LIGHTING - METALUX
®
DESCRIPTION
The accordTM redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accordTM provides the right amount
of light while eliminating surface shadows commonly found in
parabolics. Therefore, accordTM increases the comfort level while
providing significant energy savings.
Type
Catalog #
FIXTURE CE-2AC-232T8-UNV-EB81-EL
(WITH EMERGENCY BALLAST IN
Project
FIXTURE)
Date
Comments
The accord is the ideal solution for offices, schools, hospitals,
retail and other applications.
TM
Prepared by
SPECIFICATION FEATURES
A…Construction
C…Ballast Access
F…Shielding
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end plates
are securely attached with screws for
strength and rigidity and the elimination of gaps. Four auxiliary fixture end
suspension points are provided. KOs
for continuous row wiring. Large
access plate for supply connection.
Ballast can be removed from
below without tools.
Positively retained frosted
acrylic profile lenses provide a
soft but effective distribution of
light.
B…Electrical*
E…Ref lector s
Ballasts are Class “P” and are positively secured. Rotor-lock lampholders
ensure positive lamp retention.
UL/CUL listed. Suitable for damp
locations.
Reflector has high reflectance
baked matte white enamel finish for luminous uniformity.
D…Finish
Durable cold rolled steel with
multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.
G…Air Return
Optional Air Return model
provides air flow through air
slots in the housing.
2AC
232T8
T8 LAMPS
2' x 4' Recessed
Tr o f f e r S e r i e s
B
A
D
C
E
F
3-1/4"
[83mm]
23-3/4"
[603mm]
LAMP CONFIGURATIONS
MOUNTING DATA
Access Plate
11-3/4" [298mm]
1-1/2" [204mm]
3-1/4"
[83mm]
ENERGY DATA
23-3/4" [603mm]
Input Watts:
EB Ballast & STD Lamps @ 277V
232 (58)
23-3/4"
[603mm]
Luminaire Efficacy Rating
LER =FL83 LPW
Catalog Number: 2AC-232
48" [1219mm]
8" [204mm]
4-13/16" [123mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $2.89
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
COOPER LIGHTING
F
Drywall Frame
Kit
Ceiling
Type**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF080359
2AC
PHOTOMETRICS
2AC-232-UNV-EB81
Electronic Ballast
(2) F32T8/835 Lamps
3100 Lumens each
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.5 x
mounting height
Efficiency 85%
Test Report:
241P14200
Candlepower
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
LER = FL83 LPW
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.89
Along II
1614
1607
1587
1551
1502
1440
1366
1280
1184
1080
967
848
723
589
452
315
187
81
0
Across ⊥
1614
1618
1605
1587
1558
1521
1477
1425
1366
1298
1221
1134
1022
857
664
465
277
113
0
45°
1614
1612
1596
1569
1531
1483
1425
1358
1282
1198
1107
1007
899
783
635
456
280
118
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
101
92
83
75
69
63
58
54
50
46
44
101
87
75
66
58
51
46
42
38
35
32
101
83
69
58
50
43
38
34
30
28
25
101
80
64
53
44
38
33
29
25
23
21
99
89
81
73
67
61
56
52
48
45
42
99
85
74
64
57
50
45
41
37
34
32
99
82
68
58
49
43
38
34
30
27
25
99
79
63
52
44
37
32
28
25
23
20
20%
50%
50 30 10
30%
50 30 10
50
94
82
71
62
55
49
44
40
36
33
31
90
78
68
59
53
47
42
38
35
32
30
87
75
65
57
51
45
41
37
34
31
29
94
79
66
56
48
42
37
33
30
27
25
94
76
62
51
43
37
32
28
25
22
20
90
76
64
54
47
41
36
32
29
27
24
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1280
2129
3945
5271
5271
%Lamp
20.6
34.3
63.6
85.0
85.0
%Fixture
24.3
40.4
74.9
100.0
100.0
Average
0-Deg
cd/sm
2188
2118
1996
1743
1331
90
74
60
50
42
36
32
28
25
22
20
10%
30 10
87
73
62
53
46
40
36
32
29
26
24
Average
45-Deg
cd/sm
2427
2515
2654
2524
1939
0%
0
87
72
59
49
42
36
31
28
25
22
20
85
70
57
47
40
34
30
26
23
21
19
Average
90-Deg
cd/sm
2630
2832
2905
2574
1857
ORDERING INFORMATION
SAMPLE NUMBER: 2AC-232-UNV-EB82-U
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
Type
A=Air (optional)
(1)
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
32=32W T8 (48")
Shielding
Blank=Frosted Acrylic
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
Voltage (1)
UNV=Universal
Voltage 120-277
Lamps
L8835=T8 Lamp, 17W
and 32W, 3500K
L8841=T8 Lamp, 17W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
NOTES: Products also available in non-US voltages and frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice.
Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
No. of
Harmonic Distortion < 20%
Ballast
1 or 2
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
HPT8 Ballast
Ballast
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG
SHIPPING INFORMATION
Catalog No.
Wt.
2AC-232
28 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
6/10
ADF080359
COOPER LIGHTING - METALUX
DESCRIPTION
The VT2 Series is an energy efficient industrial Vaportite fixture that features
rugged and durable construction. The VT2 incorporates a full metal fixture
liner inside a reinforced fiberglass housing with a high impact diffuser. This
Vaportite series is suitable for interior and exterior applications and can be
surface or chain mounted.
Type
Catalog #
Project
FIXTURE
DE-VT232-DREMERGENCY (WITH
Comments
EMERGENCY BALLAST IN
FIXTURE)
Prepared by
The VT2 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
temperature, humidity and dust or corrosive fumes are present.
®
Date
SPECIFICATION FEATURES
A ... Construction
Fiberglass housing is reinforced
polyester and self-extinguishing
(ASTM-D635-74) plastic of a
permanent pearl gray color. Top of
housing has nine embossments
(4' unit) and thirteen embossments
(8' unit), providing mounting
flexibility on uneven surfaces. A
watertight hub for 1/2" conduit
entry is provided at each end of
housing (standard) for continuous
feed. Polyurethane gasketing is
formed in the housing providing a
continuous seamless seal for the
diffuser. Six sturdy cam latches (4'
unit) and twelve (8' and tandem
unit) clamp diffuser tightly for a
positive seal between housing,
gasketing and diffuser.
B ... Electrical*
Unit has full metal liner (channel)
secured by brass internal/external
mounting studs for positive
grounding, maximum protection
and rigidity. Ballasts are CBM/ETL
Class "P" certified suitable to plus
50°F. Spring loaded lampholders.
Electrical components and fixtures
are UL/CUL listed for Wet
Locations.**
IP65 approved (4' only).
C ... Lens
"DR" - Clear low brightness pattern
acrylic with 15% high impact
additive.
"DR-100" - Clear low brightness
pattern acrylic with 100% high
impact additive.
Example: VT2-296DR-100
"LEX" - High impact clear low
brightness pattern polycarbonate.
LEXAN
Example: VT2-296LEX.
VT2
132
232
332
154T5
254T5
D ... Reflectors
Optional die formed finished or
95% specular miro reflector.
A
B
C
5-7/8"
[149mm]
4' OR 8' INDUSTRIAL
1, 2 OR 3 LAMP T8
1 OR 2 LAMP T5HO
7" [178mm]
LAMP CONFIGURATIONS
MOUNTING DATA
2-lamp
1-lamp
Z
5"
[127mm] X
Y
6-5/8"
[168mm]
7"
[178mm]
W=2-5/8"
[67mm]
X=2-1/8"
[54mm]
3-lamp (T8 Only)
Z
5"
[127mm] X
Y
Z
5"
[127mm] X
W
6-5/8"
[168mm]
7"
[178mm]
Y=3-3/16"
[81mm]
41-1/2" [1054mm]
Optional Back Hub
Locations
Y
38-3/4" [984mm]
1/4" x 28" Stud
(2 Places)
W
6-5/8"
[168mm]
7"
[178mm]
E N E R G Y D ATA
6-5/8"
[168mm]
Input Watts:
X=5-3/8"
[137mm]
Y=5-3/8"
[102mm]
Z=1-1/2"
[38mm]
Vaportight Industrial
Y
X
EB Ballast & T5HO Lamps
254T5 (121), 8T254T5 (242)
49-13/16" [1265mm]
EB Ballast & T5HO Lamps
154T5 (62), 254T5 (117)
89-1/2" [2273mm]
Optional Back Hub
Locations
EB Plus Ballast & STD Lamps
132 (46), 232 (73), 332 (108)
87-1/16" [2211mm]
1/4" x 28" Stud
(4 Places)
Luminaire Efficacy Rating
LER = FI-73
Catalog Number: VT-232DR
6-5/8"
[168mm]
X=5-3/8"
[137mm]
Y=5-3/8"
[102mm]
40-13/16"
[1037mm]
X
5-1/8"
[130mm]
97-13/16" [2484mm]
EB Ballast & STD Lamps
132 (36), 232 (57), 332 (82)
40-13/16"
[1037mm]
Y
INSTALLATION DATA
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.29
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Not Suitable for Wet Locations if EL4
Option is added. Consult Pre Sales
Technical Support.
MOUNTING BRACKETS
Furnished
Two per 2' and 4' Unit
Four per 8' Unit
OPTIONAL CHAIN HANGING SET
(VT2-CHAIN/SET-U)
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Includes 6 ft. of chain, 4 large S-Hooks and 4
small S-Hooks
Order One (1) Kit for each 2' or 4' Fixture
Two (2) Kits Recommended For 8' Fixture
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
Safe and convenient means of
disconnecting power
ADF071394
09/29/2008 10:06:07 AM
PHOTOMETRICS
VT2
VT2-254DR-UNVEB81-WL-M4-U
Electronic Ballast
(2) F54/T5/835 Lamps
4460 Lumens each
?
Spacing criterion:
(II) 1.2 x mounting
height, (? ) 1.6 x
mounting height
||
Efficiency 74.3%
Test Report:
127P111
LER = FI57
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.24
Along II
1615
1613
1592
1556
1504
1438
1357
1262
1154
1033
902
762
621
485
362
253
158
74
26
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Across ?
1615
1648
1723
1781
1820
1839
1815
1743
1635
1499
1355
1180
994
968
1051
992
827
647
463
45°
1615
1632
1673
1704
1717
1712
1683
1625
1532
1412
1263
1101
944
775
667
677
612
455
297
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
87
73
63
55
48
43
39
35
32
29
27
87
70
57
48
41
36
32
28
25
23
21
87
66
52
43
36
31
27
23
21
18
17
85
75
68
61
56
51
47
44
41
38
36
85
71
61
53
47
42
38
34
31
28
26
85
68
56
47
40
35
31
28
25
22
20
85
65
51
42
35
30
26
23
20
18
16
50%
50 30 10
30%
50 30 10
50
80
67
58
51
45
40
36
32
30
27
25
76
64
55
48
42
38
34
31
28
26
24
72
60
52
45
40
36
33
30
27
25
23
80
64
53
45
39
34
30
27
24
22
20
80
62
50
41
34
30
26
23
20
18
16
76
61
51
43
38
33
29
26
23
21
19
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
15.8
26.9
49.1
70.3
74.2
Along II
1036
1036
1023
1000
968
926
876
817
750
674
591
501
408
317
233
160
97
45
16
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Spacing criterion:
(II) 1.3 x mounting
height, (? ) 1.6 x
mounting height
||
Efficiency 81.7%
Test Report:
127P113
LER = FI71
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.39
20%
Zonal Lumen Summary
Lumens
1411
2397
4380
6268
6614
?
Candlepower
Across ?
1036
1077
1175
1275
1344
1352
1284
1182
1070
946
833
780
785
816
755
624
518
434
353
45°
1036
1059
1114
1175
1227
1255
1245
1184
1080
961
834
706
597
533
520
489
396
302
224
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
87
78
70
64
58
53
49
45
42
39
37
VT2-232DR-UNVEB81-WL-M4-U
Electronic Ballast
(2) T8 Lamps
2850 Lumens each
Candlepower
%Fixture
21.3
36.2
66.2
94.8
100.0
Average
0-Deg
cd/sm
7779
7074
6110
5205
4251
76
59
48
40
34
29
25
22
20
18
16
10%
30 10
72
59
49
42
36
32
28
25
23
21
19
72
57
46
39
33
28
25
22
19
17
16
Average
45-Deg
cd/sm
10632
10221
9764
13928
27797
0%
0
70
55
44
37
31
26
23
20
18
16
14
Average
90-Deg
cd/sm
11288
10954
12196
20408
39527
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
96
86
77
70
64
58
54
50
46
43
40
96
81
69
60
53
47
42
38
35
32
29
96
77
63
53
45
39
35
31
28
25
23
96
73
58
47
40
34
29
26
23
20
18
93
83
74
67
61
56
52
48
45
42
39
93
78
67
59
52
46
41
37
34
31
29
93
74
61
52
44
39
34
30
27
25
22
93
71
57
46
39
33
29
25
22
20
18
20%
50%
50 30 10
30%
50 30 10
50
87
74
63
55
49
44
39
35
32
30
27
82
69
60
52
46
41
37
34
31
28
26
78
65
56
49
44
39
35
32
29
27
25
87
70
58
49
43
37
33
29
26
24
22
87
68
54
45
38
32
28
25
22
20
18
82
67
56
47
41
36
32
28
25
23
21
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
985
1675
2999
4316
4658
%Lamp
17.3
29.4
52.6
75.7
81.7
%Fixture
21.1
36.0
64.4
92.7
100.0
Average
0-Deg
cd/sm
4874
4392
3669
2853
1868
82
64
52
43
37
31
27
24
21
19
17
10%
30 10
78
63
53
45
39
34
30
27
25
22
20
78
61
50
42
35
31
27
24
21
19
17
Average
45-Deg
cd/sm
6095
5171
4791
5921
5874
0%
0
76
59
48
40
33
29
25
22
19
17
15
Average
90-Deg
cd/sm
5343
4906
5995
5721
5512
ORDERING INFORMATION
S A M P L E N U M B E R : 8 T V T 2 - 2 5 4 D R - U N V- E B 8 2 - M 4 - U
Width
Blank=4' Length
8T=8' Length
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
UNV=Universal
Voltage 120/277V
UNC=Universal
Voltage 347/480V
(T5 Linear Only)
Series
VT2=Vapor-Tite
Number of Lamps (3)
1=1 lamp (T5 or T8)
2=2 lamps (T5 or T8)
3=3 lamps (T8 only)
Fusing
GL=Single Element Fuse
GM=Double Element Fuse
Emergency=EM Installed,
see EM options table (3) (4)
(Lamps not included)
Lamp Type
32=32W T8 Lamp (4' Long)
54T5=54W T5HO Lamp (4' Long)
Lens
DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard)
DR-100%=100% High Impact Additive
LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern
(1)
WL=Wet
Location
Ballast Type (1)
Label
T8 Systems
EB8 =T8 Electronic Instant Start.(4)
Total Harmonic Distortion < 20%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
No. of
Harmonic Distortion < 20%
Ballast
1 or 2
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
ER8 /PLUS= T8 Electronic Program Start.
High Ballast Factor >1.13. Total
No. of
Harmonic Distortion < 10%
Ballast
1 or 2
EB8 /L= T8 Electronic Instant Start w/0.80
Ballast Factor.
No. of Ballast
1 or 2
T5 Systems
EBT =T5HO Electronic Program Start.
(2)
NOTES: Ballast type used only if ballast & voltage is chosen Not available when specify(3)
ing emergencies, voltage must be specific. T5HO is only available in 1 or 2-lamp versions
(4)
only. Emergency option in 3 lamp version must use remote mount test switch.
No. of Ballast
1 or 2
Packaging
Options
U=Unit Pack
RIF1=Radio
Interference Suppressor
PALC=Job
Pack in Carton
TH=(2) Top Watertite Hubs
TEH=(2) Top & (2) End Watertite
Hubs (all Watertite Hubs have 1/2"
Conduit Entry)
TILW=Tandem In-Line Wiring
Option (Consult TILW Option Catalog Page)
PI/CPI=Plug-In Option
DD=Deep Diffuser (4' Length)
(Available for 4' Fixture Length) To Complement
Deep Diffuser Depth of 8' Fixture
M4=Specular Reflector
SSL=Stainless Steel Latches
ACCESSORIES
Accessories (order separately)
VT2-Chain/Set-U=Chain Hanging Set
Includes 6 ft. of chain, 4 large
S-Hooks and 4 small S-Hooks
Order One (1) Kit for each
2' or 4' Fixture
Two (2) Kits Recommended
For 8' Fixture
VT2-SS-MBK=Stainless
Steel Mounting Bracket
SHIPPING DATA
Catalog No.
VT2-132DR-WL
VT2-232DR-WL
Specifications and Dimensions subject to change without notice.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
Wt.
35 lbs.
35 lbs.
ADF071394
09/29/2008 10:06:07 AM
COOPER LIGHTING - METALUX
®
DESCRIPTION
The GR8 is a T8-dedicated lensed troffer designed to offer premium
performance in a low profile housing. T8 dedication and optimized
lamp to lens spacing provides the best in energy efficiency and optical
control. The GR8’s shallow, low profile housing is compatible with even
highly restrictive plenums. Luminaires are compatible with today’s
popular ceiling systems. The GR8 offers great performance and great
quality. The series is an excellent choice for commercial offices,
schools, hospitals, retail merchandising and many other applications.
Type
Catalog #
Project
FIXTURE
OE-2GR8-232-UNVEB81-EL (EMERGENCY
Comments
BALLAST IN FIXTURE)
Date
Prepared by
SPECIFICATION FEATURES
Construction
Electrical**
Hinging/Latching
Unitized low profile recessed
housing is die formed of code
gauge prime cold rolled steel with
full length stiffeners and unibody
endplate for added strength.
Ballast cover is easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring for easy
lampholder replacement. Ample
KOs are provided for continuous
row wiring. Built-in grid-lock
feature for safety and convenience.
Ballasts are CBM/ETL Class “P”
and are positively secured by
mounting bolts. Rotor-lock
lampholders. UL/CUL listed.
Suitable for damp locations.
Positive spring loaded steel
latches and safety lock T-hinges
provide secure, high quality
door fit and allow hinging and
latching from either side.
Finish
Frame/Shielding
Multistage, iron phosphate
pretreatment ensures maximum
bonding and rust inhibition.
Lighting grade baked white
enamel finish with premium
reflectance for high efficiency.
Heavy gauge flat steel door is
die formed with reinforced
mitered corners. Housing and
door frame assemblies
incorporate full width
mechanical light traps. Light
stabilized, acrylic prismatic lens.
2GR8
228T8
232
428T8
432
2' X 4' TROFFER
2 OR 4 LAMP
General Purpose
T8 Commercial Troffer
3-1/4"
[83mm]
ENERGY DATA
Input Watts:
EB Ballast & STD Lamps
228T8 (49), 232 (61)
428T8 (98), 432 (122)
23-3/4" [603mm]
LAMP CONFIGURATIONS
MOUNTING DATA
2 LAMP
Location of Standard
Access Opening
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $2.93
3-1/4" [83mm]
1-1/2"
[38mm]
1-1/2"
[38mm]
10-3/4"
[274mm]
23-3/4" [603mm]
23-3/4"
[603mm]
3-1/4" [83mm]
3-1/8"
[80mm]
47-15/16" [1218mm]
Catalog Number: 2GR8-432A
LER = FL-76
4 LAMP
1"
[26mm]
3-1/2"
[89mm]
Luminaire Efficacy Rating
LER = FL-82
Catalog Number: 2GR8-232A
X=4-3/16"
[107mm]
Y=4-3/4"
[121mm]
X
Y
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.16
X
23-3/4" [603mm]
*Standard G (Grid) Type Fixtures can be
field converted by adding trim kits. See
Compatibility Section or Consult Factory.
DOOR FRAMES
2GR8
Flat, White
Steel (White
Latches)
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
***When ordering Flange Kit for
installation in drywall ceilings, see options
and accessories compatibility section and
ordering logic.
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
G
Concealed T
COOPER LIGHTING
G
Slot Grid
F
Flange Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G
G
G***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL,
STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF012707
2GR8
PHOTOMETRICS
2GR8-232A
Electronic Ballast
(2) F32T8 lamps
3100 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 79.4%
Test Report:
2GR8-232A.IES
LER = FL-82
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.93
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1851
1855
1830
1790
1731
1653
1554
1434
1297
1127
922
731
570
430
316
224
162
87
0
Across ⊥
1851
1851
1845
1834
1813
1776
1720
1650
1551
1400
1182
924
675
476
343
262
198
114
0
45°
1851
1846
1830
1806
1768
1714
1643
1551
1424
1251
1060
851
619
413
261
179
142
89
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
95
83
73
65
58
52
47
43
39
36
33
95
80
68
59
51
45
40
36
32
29
27
95
77
64
54
46
40
35
31
28
25
23
92
85
77
71
65
60
56
52
48
45
42
92
82
72
64
57
51
46
42
38
35
33
92
79
67
58
51
45
40
36
32
29
27
92
76
63
53
46
40
35
31
28
25
23
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
88
78
69
61
55
49
45
41
37
34
32
84
75
66
59
53
48
43
40
36
33
31
81
72
64
57
51
46
42
39
35
33
30
79
68
57
49
42
37
32
29
26
23
21
88
76
65
56
49
44
39
35
32
29
26
88
74
62
52
45
39
35
31
28
25
23
84
73
63
55
48
43
38
34
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1476
2440
4149
4924
4924
%Lamp
23.8
39.4
66.9
79.4
79.4
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
3662
3664
3613
3531
3413
3260
3067
2829
2538
2188
1816
1457
1138
859
626
447
314
172
14
Across ⊥
3662
3657
3640
3610
3555
3461
3327
3155
2918
2591
2176
1729
1304
950
687
517
380
214
47
45°
3662
3647
3614
3560
3480
3365
3206
2998
2723
2383
2023
1630
1212
827
530
359
272
167
33
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
95
87
80
73
67
62
57
53
49
46
43
2GR8-432A
Electronic Ballast
(4) F32T8 lamps
3100 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 77.1%
Test Report:
2GR8-432A.IES
LER = FL-76
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.16
Candela
%Fixture
30.0
49.6
84.3
100.0
100.0
Average
0-Deg
cd/sm
2556
2044
1632
1388
1601
84
71
60
52
45
39
34
31
27
25
22
81
71
61
54
47
42
38
34
31
28
26
81
69
59
51
44
38
34
30
27
25
22
Average
45-Deg
cd/sm
2838
2380
1567
1109
1638
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Average
90-Deg
cd/sm
3176
2594
1807
1624
2098
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
92
84
77
71
65
60
56
52
48
45
42
92
81
71
63
56
50
46
41
38
35
32
92
78
66
57
50
44
39
35
31
29
26
92
75
62
52
45
39
34
30
27
24
22
90
82
75
69
63
58
54
50
47
44
41
90 90
79 76
70 65
62 56
55 49
50 43
45 39
41 35
37 31
34 28
32 26
90
74
61
52
44
39
34
30
27
24
22
20%
50%
50 30 10
30%
50 30 10
50
86
76
67
60
53
48
43
40
36
33
31
82
73
65
57
52
46
42
39
35
33
30
79
70
62
56
50
45
41
37
34
32
30
86
74
63
55
48
42
38
34
31
28
26
86
71
60
51
44
38
34
30
27
24
22
82
71
61
53
47
42
37
33
30
28
25
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
2902
4769
8035
9566
9566
%Lamp
23.4
38.5
64.8
77.1
77.1
%Fixture
30.3
49.9
84.0
100.0
100.0
82
69
59
50
43
38
33
30
27
24
22
Average
0-Deg
cd/sm
4963
4074
3260
2770
3165
Average
45-Deg
cd/sm
5406
4558
3139
2225
3073
10%
30 10
79
69
60
52
46
41
37
33
30
27
25
0%
0
79
67
57
49
43
37
33
30
27
24
22
77
66
56
48
41
36
32
28
25
23
21
Average
90-Deg
cd/sm
5877
4835
3606
3204
3938
ORDERING INFORMATION
SAMPLE NUMBER: 2GR8-232A-UNV-EB81-U
Rating (4)
Blank=
Standard
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Trim Type
G=Grid/Lay-in
(Standard)
Series
R8=General Purpose
T8 Commercial
Troffer (1)
(1)
Number of
Lamps
2=2 Lamps
4=4 Lamps
Options
FR=Fire Label
Voltage (2)
347V=347 Volt
UNV=Universal Voltage
120-277 (3)
(Not included)
Wattage
28T8=28W T8 (48")
32=32W T8 (48")
Shielding
A=#12 Acrylic Pattern
A125=#12 Pattern Acrylic
(.125" Thick)
A19/156=#19 Pattern
Acrylic (.156" Thick)
PB1S=Silver Parabolic
Louver (1/2" x 1/2" x 1/2")
Packaging
U=Unit Pack
Ballast Type (2)
ACCESSORIES
EB8 = T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EQ-CLIP-U=T-BAR Safety Earthquake Clips (1)
No. of Ballast
FCTKA-24W-U=Field Installed Flange Kit
1 or 2
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.
No. of
Total Harmonic Distortion < 10%
Ballast
N=Natural
Trim Kit
22=2' x 2'
1 or 2
Field
W=White
24=2' x 4'
ER8 = T8 Electronic Program Rapid Start.
Convertible
Total Harmonic Distortion < 10%
U=Unit Pack
Blank=Single
No. of Ballast
Aluminum
R=In Row
1 or 2
E=End Row
High Performance T8 Ballast (HPT8)
HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77
HB8 =T8 Electronic Instant Start. Ballast Factor .88
HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start. Low Ballast Factor .77
HR8 =T8 Electronic Program Start. Ballast Factor .88
HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed
FCTK
Lamps Installed
Blank=No Lamps Installed
L8835=T8 Lamp, 28W and
32W, 3500K
L8841=T8 Lamp, 28W and
32W, 4100K
L8835HL=T8 Lamp, 32W,
3500K, 3100 Lumens
L8841HL=T8 Lamp, 32W,
4100K, 3100 Lumens
(2)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and
(3)
(4)
frequencies for international markets. Not available when specifying emergencies, voltage must be specific. For NYC rated product, see separate
specification sheets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
A – 24
R W – U
SHIPPING INFORMATION
Catalog No.
Wt.
2GR8-228T8A
2GR8-232A
2GR8-428T8A
2GR8-432A
20 lbs.
20 lbs.
20 lbs.
20 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
7/11
ADF012707
CORELITE
DESCRIPTION
Corelite's Minigator suspended direct-indirect fluorescent luminaire features
a rugged aluminum construction, petite profile, elegant styling, cross blade
louver and optional adjustable uplight and downlight optics for evolving
interior spaces. Our Slide-N-Lock TM optics accessory allows the designer to
adjust the amount of uplight and downlight for a particular application. The
Minigator may be mounted individually or continuously with 4', 8' and 12'
modular sections. Luminaires align with T-Grid and interface with all ceiling
types. The Minigator is suited for open offices, private offices, conference
rooms, reception areas and educational facilities.
Type
Catalog #
Project
FIXTURE SE-MB-132-TB-UNV-EB81-E
Date
BALLAST IN
FIXTURE)
Prepared by
Comments
(WITH EMERGENCY
SPECIFICATION FEATURES
A ... Construction
Housing is 6063 T5 aluminum
extrusion forming a 6-3/4" x 2-1/2"
rounded profile. Standard 4'-0",
8'-0" and 12'-0" fixture lengths
combine for continuous runs.
D ... Reflectors
Reflector pan is painted with a high
reflectance white powder coat
finish. Optional die-formed side
reflectors are highly specular
anodized aluminum.
B ... End Caps
Standard end caps are precision
die-cast aluminum, mechanically
attached without exposed
fasteners.
E ... Electrical
T5/T5HO fixtures are pre-wired
with quick wire connectors and use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, power
factor of 97% with less than 10%
THD. Fixtures and electrical
components certified to UL and
CUL standards.
C ... Louver
A continuous semi-specular
aluminum parabolic 1-1/4" blades
spaced 2-1/4" on-center with a
2-3/4" opening.
A
C
E
D
F ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
Mounting
Standard aircraft cable mounts on
4'-0", 8'-0" and 12'-0" centers. Refer
to installation section for various
ceiling interface details and rigid
pendant mounting details.
Minigator
Cross Blade
Parabolic Louver
B
F
1T5
1T5HO
Suspended
Direct/Indirect
2-1/2"
[64mm]
Light Distribution
Indirect - 74.0%
Direct - 26.0%
6-3/4" [171mm]
MO DUL E S
AND
1/2" [14mm]
E nd
DIME NS IO NS *
Cap
S ide
View
48" [1219mm]
96" [2438mm]
144" [3658mm]
*Dimens ions do not include end caps .
ORDERING INFORMATION
Sample Number: MB-WB-1T5-1C-UNV-AC48-T1-12
Series
MB=Minigator Suspended
Number of Lamps
1=1 Lamp
Number of Circuits
1=1 Circuit
Optics Up
S=Specular
Lamp Type
N5=T5 Normal Output
Wiring 1
B=Battery Pack
W=White
T5=T5 High Output
C=Standard Circuit
D=Dimming
Optics Down
B=Cross Blade Louver
1
E=Emergency
T=Nightlight
Y=Daylight
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and dimensions subject to change without notice.
Consult adder section of the price guide for additional standard lengths.
Voltage 1
120=120V
277=277V
347=347V
UNV=Universal
(120V277V)
Suspension
A=Aircraft Cable
Suspension Length
Adjustable Cable
48", 120", 240", 300", or
360" (infinite adjustment
along entire length of
cable)
Rigid Pendant
2
12", 15", 18", 21", 24", or
27"
P=Rigid Pendant
Power Feed 1
C=Straight Cord
K=Curly Cord
P=Rigid Pendant
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
Ceiling Type
T1=1" T-Bar
Options
T9=9/16" T-Bar
TS=Slotted T-Bar
DL1
ST=Structure
JB=4" Octagonal
J-Box
DL3
Slide-N-Lock™
DL2
DL4
DL5
DL6
Run Length
Individually Mounted
Luminaires may be 4',
8', or 12' in length
DL7
DL8
Continuously
Mounted
Standard row
configurations over
12' consist of 8' and
12' sections
ADE032183
08/14/2009 3:20:50 PM
PHOTOMETRICS
Corelite
C o e f f i c i e n ts
C andela
E ffec tive floor c avity reflec tanc e
80%
70%
rc
rw
RCR
MB -S B -1T 5
(1) F P 54/841/HO
4500 Lumens
o f U ti l i z a ti o n
20%
50%
30%
10%
0%
A ngle
0
A long II
500
o
45
500
A c ros s I
500
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
5
15
494
461
497
491
499
529
0
1
92
85
92
81
92
78
92
75
82
76
82
73
82
70
82
67
64
57
64
55
64
54
47
42
47
41
47
40
31
28
31
28
31
28
24
21
25
35
410
339
501
580
708
534
2
3
4
5
78
71
66
60
72
64
57
50
67
58
50
44
63
53
46
39
69
64
59
54
64
57
51
46
60
52
46
40
57
49
42
36
51
45
41
37
48
42
37
33
45
39
34
29
38
34
31
28
36
32
28
25
35
30
27
23
26
24
22
20
25
23
20
18
24
22
19
17
19
17
15
14
45
55
65
75
249
125
27
11
294
68
33
13
114
70
59
17
6
7
8
9
56
51
47
44
46
41
37
33
39
34
30
27
34
30
26
23
50
46
42
39
41
37
33
30
35
31
28
25
31
27
24
21
33
30
27
24
29
26
23
20
26
23
20
17
25
23
21
19
23
20
18
16
21
18
16
14
18
17
15
14
17
15
13
12
15
14
12
11
12
11
10
09
85
90
95
105
3
0
17
88
5
0
142
535
7
0
123
580
10
41
30
24
20
36
28
22
19
22
18
15
17
14
12
12
11
09
08
115
189
600
932
125
135
298
396
545
605
835
707
145
155
165
175
180
483
550
597
621
623
630
646
642
628
623
715
695
662
624
623
E fficiency 90.9%
T es t R eport
#LS I17896
Zonal L umen S ummary
L u m i n a n c e D a ta
Zone
0-30
0-40
0-60
L umens
434
730
1006
%L amp
9.65
16.24
22.36
%F ixture
10.62
17.87
24.60
A ngle
0-Deg
in Deg
45
55
c d/s m
4810
2974
45-Deg
c d/s m
5677
1633
90-Deg
c d/s m
2211
1683
0-90
40-90
60-90
1064
333
58
23.66
7.42
1.30
26.03
8.17
1.43
65
75
85
889
579
578
1070
694
844
1920
900
1250
90-180
0-180
3025
4089
67.23
90.89
73.97
100.00
COMMON CIRCUIT CONFIGURATIONS FOR TWO LAMP SUSPENDED FIXTURE
1C =S ingle circuit luminaire
1E =S ingle circuit luminaire with emergency circuit
1C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
=E mergency C ircuit
1E
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
144"(3658mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
12'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
2
1
1
1
2
2
1
1
2
3
2
1
2
3
4
52' 56' 60' 64' 68'
2
1
3
4
5
2
1
4
5
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
6
2
1
5
6
7
Specifications and Dimensions subject to change without notice.
Corelite • 4675 A Holly Street • Denver, CO 80216 • 303.393.1522 • FAX 303.393.1477
2
1
6
7
8
2
1
7
8
9
ADE032183
08/14/2009 3:20:50 PM
C orelite's lates t innovation, S lide-N-Lock T M optics revolutionizes the concept of variable uplight and downlight
percentages within a direct-indirect fluores cent luminaire. S lide-N-Lock T M optics cons is ts of two s liding parts
des igned to provide combinations of uplight and downlight in approximately 5% increments . T he uplight range
begins at approximately 5% (fully clos ed) and ends at approximately 40% (fully open). T he optics will be factory
s et to the s pecified s etting, although it can be field adjus ted. T o adjus t, s imply depres s the control notch, then
"s lide-n-lock" the optic into the des ired s etting. T he S lide-N-Lock T M optics s imply s lides in and out of the top of
the Minigator hous ing for eas y lamp maintenance.
(P atent P ending)
MB -S B -1T 5-DL -1
MB -S B -1T 5-DL -2
R eport # F T L89083
Direct - 95.3%
Indirect - 4.7%
E fficiency 59.2%
R eport # F T L89082
Direct - 93.4%
Indirect - 6.6%
E fficiency 59.8%
MB -S B -1T 5-DL -3
MB -S B -1T 5-DL -4
R eport # F T L89081
Direct - 90.1%
Indirect - 9.9%
E fficiency 60.8%
R eport # F T L89080
Direct - 85.0%
Indirect - 15.0%
E fficiency 62.3%
MB -S B -1T 5-DL -5
MB -S B -1T 5-DL -6
R eport # F T L89079
Direct - 80.5%
Indirect - 19.5%
E fficiency 63.9%
R eport # F T L89078
Direct - 75.7%
Indirect - 24.3%
E fficiency 65.7%
MB -S B -1T 5-DL -7
MB -S B -1T 5-DL -8
R eport # F T L89077
Direct - 69.9%
Indirect - 30.1%
E fficiency 67.9%
R eport # F T L89076
Direct - 64.1%
Indirect - 35.9%
E fficiency 70.4%
Specifications and Dimensions subject to change without notice.
Corelite • 4675 A Holly Street • Denver, CO 80216 • 303.393.1522 • FAX 303.393.1477
ADE032183
08/14/2009 3:20:50 PM
Download