multmed modular medical bed light

advertisement
MM
MULTMED MODULAR MEDICAL BED LIGHT
SUBMITTAL:
JOB:
VOLTAGE:
TYPE:
MM 4 AE R N G
EXAMPLE
t
t
t
-
250T T/450T T/150T T
t
SERIES NOM.
STYLE
CEILING
L.
AMBIENT EXAM READINGTYPE
-
OP TIONS
t
-
E B2- E B2/2- E B1
t
# LAMPS AND LAMP WATTAGE/TYPE
OPTIONS
AMBIENT/EXAM/READING
-
UNV
t
t
BALLAST TYPE
VOLTAGE
AMBIENT-EXAM-READING
FEATURES
Ambient, exam, reading and nurse light styles offer design
flexibility.
XX
The ambient style module delivers a broad wash of soft, even
illumination.
XX
Exam light provides abundant shadow-free illumination on the
bed by using crossing beams of focused light.
XX
The reading light module provides a soft, glare-free pool of
light to the patient’s reading area.
XX
Nurse lights direct appropriate amounts of focused light to
either side of patient bed while completely shielding light
from the patient’s view.
XX
Sani-Shield option protects fixture from dust, bugs and other
contaminants while simplifying maintenance and cleaning.
XX
Double-gasketed to ensure proper seal, the Sani-Shield
option features T-slot steel hinges to allow reversible hinging
and latching and spring-loaded cam latches to provide years
of hassle-free maintenance.
XX
Optional low-voltage controller allows for bedside lighting
control.
XX
Swing-down diffusers allow for tool-less lamp replacement.
XX
Anti-microbial white finish standard.
XX
This fixture is proudly made in the USA.
XX
ORDERING INFORMATION
SERIES
MM NOMINAL LENGTH
1
2
4
G
F
NEMA Type “G”
NEMA Type “F”
NUMBER OF LAMPS &
LAMP WATTAGE/TYPE CONFIGURATIONS 2
2’ x 1’ (23-7/8” W. x 11-7/8” L.)
2’ x 2’ (23-7/8” W. x 23-7/8” L.)
2’ x 4’ (23-7/8” W. x 47-7/8” L.)
See tables on pages 1B-1C for lamp quantities and combinations.
OPTIONS
STYLE
Styles must be specified in order: 1) Ambient 2) Exam 3) Reading.
See table on pages 1B-1C for lamp quantities and combinations.
STYLE
CONFIG.
A
Ambient
A
AX
AX
DESCRIPTION
Ambient – extended length
E
E
Exam
E
EX
EX
Exam – extended length
1
For generic EM ballast options (must specify voltage),
see Fluorescent Information section.
GLR
Fuse, fast blow (specify voltage),
one per ballast
SS
Sani-Shield acrylic cover with double gasket
SG/MYLAR
Single gasket (fixture to grid)
NL13Q/EB1*___ Nurse light, one 13-watt, 4-pin, G24q-1
base CFL lamp (by others) and electronic
ballast standard, must specify 120V, 277V,
or UNV
3
Curbell model #LC-060 low-voltage
LVC*C60__ controller, specify A (Ambient), R (Reading),
or AR (Ambient and Reading), 120V or
3
277V only
BALLAST TYPE
W
1
+1
W
Nurse light includes one 7-watt,
2-pin, G23-base CFL lamp and
magnetic ballast standard (do not
1
specify lamp, lamp by others)
Wiring compartment houses
electrical equipment and
connections in room-side
accessible cabinet with tool-less
1
access (do not specify lamp).
Use “+” to indicate multiple
fixtures wired together, installed up
to 2’ apart (see page 1D for ordering
1
examples).
H.E. Williams, Inc.
Carthage, Missouri
AMBIENT
N
Reading
EXAMPLE: EB2-EB2/2-EB1
DESCRIPTION
EB2
2-lamp electronic ballast
EB2/2
(2) 2-lamp electronic ballasts
EXAM
1
CATALOG #
EB2
EB2/2
EB4
2-lamp electronic ballast
(2) 2-lamp electronic ballasts
4-lamp electronic ballast (T5HO only)
READING
N
R
EB1
1-lamp electronic ballast
VOLTAGE
120
277
5-1/2”
23-7/8”
Shown with SS option
Housing – 20-gauge die formed C.R.S.
Shielding –
Ambient: Die-formed C.R.S., 50% open
perforation, white polyester powder coated
diffuser with matte white acrylic overlay.
Exam: Ribbed asymmetric linear
prismatic acrylic diffusers.
Nurse Light: Clear acrylic in steel frame.
Finish – Highly-reflective non-glare
matte white anti-microbial powder coat
bonded to phosphate-free, multi-stage
pretreated metal. All parts painted after
fabrication to facilitate installation,
increase efficiency, and inhibit corrosion.
Electrical – Electronic ballast standard, rated
Class P. Default offering shown in chart below.
1, 2
EX
R
23-7/8”
Shown without SS option
SPECIFICATIONS
CEILING TYPE
MulTmed Modular Medical Bed Light
4-5/8”
w w w.hew.com
UNV
347
417-358-4065
120-277V
347V
Instant
Start
T5
39TT
40TT
50TT
55TT
•
Program
Start
•
•
•
•
Mounting – NEMA Type “G” standard.
NEMA Type “F” available. Four (4)
earthquake clips standard.
Labels – UL/CUL listed as recessed
fluorescent luminaire suitable for dry or
damp locations. UL listed (not UL/CUL) when
specified with twin tube lamps or nurse light.
1
2
120V
277V
Lamp
3
Some fixture configurations do not allow all
ballasts to be located within the nurse light or
wiring compartment. Ballasts and electrical
connections will be located in primary fixture
or wiring compartment (when “W” or “+” is
specified) as space allows.
Specify using only those lamp and ballast
combinations defined in tables provided.
LVC*C60__ option requires 120V or 277V.
Not dimming compatible.
Healthcare
Page 1A of F
MM
NOTE: Styles must be specified in order:
1) Ambient 2) Exam 3) Reading.
MULTMED MODULAR MEDICAL BED LIGHT
STYLE DETAILS
AMBIENT
A
EXAM
E
Ambient
READING
R
Exam
1
E
EX
N
R
A
Ambient –
extended length
Reading
N
E
AX
NURSE LIGHT
Exam –
extended length
Nurse light includes one
7-watt, 2-pin, G23-base
CFL lamp and magnetic
ballast standard (do not
specify lamp, lamp by
1
others)
EX
AX
EX
WIRING COMPARTMENT
W
1
MULTIPLE FIXTURE CONFIGURATIONS
+
Wiring compartment houses electrical
equipment and connections in room-side
accessible cabinet with tool-less access
1
(do not specify lamp).
W
Use “+” to indicate multiple fixtures wired together,
installed up to 2’ apart (see page 1D for ordering
1
examples).
1
See tables on pages 1B-1C for lamp quantities and combinations.
NUMBER OF LAMPS & LAMP WATTAGE/TYPE DETAILS 1 , 2
2x1
BASE
MM1N
Nurse
2
Wiring
14T5S
21T5S
28T5S
24T5H
39T5H
54T5H
Healthcare
Page 1B of F
55TT
14T5S
21T5S
28T5S
24T5H
39T5H
54T5H
NURSE
Standard
1
1
1
# LAMPS & LAMP
TYPE EXAMPLE
Do not specify,
lamp by others
140TT
1
Do not specify
2x2
BASE
MM2A
MM2AE
39TT
40TT
50TT
55TT
50TT
1
LAMP TYPE/WATTAGE KEY
Twin Tube
16-1/2”, 39-watt long twin tube
2’, 40-watt long twin tube
2’, 50-watt long twin tube
2’, 55-watt long twin tube
T5
2’, 14-watt T5
3’, 21-watt T5
4’, 28-watt T5
T5HO
2’, 24-watt T5HO
3’, 39-watt T5HO
4’, 54-watt T5HO
40TT
1
Reading
MM1W
Some fixture configurations do not allow all
ballasts to be located within the nurse light or
wiring compartment. Ballasts and electrical
connections will be located in primary fixture
or wiring compartment (when “W” or “+” is
specified) as space allows.
Specify using only those lamp and ballast
combinations defined in tables provided.
39TT
1
MM1R
1
STYLE
# LAMPS & LAMP WATTAGE/TYPE
MM2RN
MM2N
1
STYLE
# LAMPS & LAMP WATTAGE/TYPE
39TT
40TT
50TT
55TT
14T5S
21T5S
28T5S
24T5H
Ambient
2
2
2
2
2
Ambient
2
2
2
2
2
Exam
2 or 4
2 or 4
2 or 4
2 or 4
2 or 4
Reading
1
1
1
1
1
39T5H
54T5H
NURSE
# LAMPS & LAMP
TYPE EXAMPLE
224T5H
224T5H/424T5H
Nurse
1
Standard
Nurse
1
Standard
155TT
1
MM2RW
MM2W
1
Reading
Wiring
1
Wiring
1
1
1
1
1
1
Do not specify,
lamp by others
114T5S
1
Do not specify
H.E . W illiams, In c.
C ar t hage, Mis s our i
Information contained herein is subject to change without notice.
w w w.he w.c om
417- 3 5 8 - 4 0 6 5
MM
MULTMED MODULAR MEDICAL BED LIGHT
NUMBER OF LAMPS & LAMP WATTAGE/TYPE DETAILS 1 , 2 (Continued) 2x4
BASE
STYLE
MM4A
MM4AN
1
40TT
50TT
55TT
Ambient
4
4
4
Ambient
2
2
2
Nurse
MM4AXN
1
MM4AW
1
MM4ARN
1
1
MM4AE
28T5S
24T5H
39T5H
2
2
54T5H
NURSE
2
4
2
2
2
Standard
4
Reading
1
Ambient
4
2
1
1
1
2
1
LAMP TYPE/WATTAGE KEY
39TT
40TT
50TT
55TT
255TT
14T5S
21T5S
28T5S
221T5S
24T5H
39T5H
54T5H
439TT/140TT
1
2
# LAMPS & LAMP
TYPE EXAMPLE
254T5H
Standard
Ambient
2
Twin Tube
16-1/2”, 39-watt long twin tube
2’, 40-watt long twin tube
2’, 50-watt long twin tube
2’, 55-watt long twin tube
T5
2’, 14-watt T5
3’, 21-watt T5
4’, 28-watt T5
T5HO
2’, 24-watt T5HO
3’, 39-watt T5HO
4’, 54-watt T5HO
239T5H
1
Ambient
Reading
1
Wiring
Ambient
Reading
1
Nurse
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Ambient
4
4
4
2
2
Exam
4
4
4
2
2
2
2 or 4
2
2 or 4
2
2 or 4
Ambient
Exam
1
Nurse
1
Ambient
MM4AEXN
Exam
1
Nurse
1 Ambient
MM4AXEXN
Exam
1
Nurse
Ambient
MM4AER
Exam
Reading
1
Ambient
MM4AEW
Exam
1
Wiring
1 Ambient
MM4AEXW
Exam
1
Wiring
Ambient
1
MM4AERN
Exam
Reading
1
Nurse
Ambient
1
MM4AEXRN Exam
Reading
1
Nurse
Ambient
1
MM4AERW
Exam
Reading
1
Wiring
Ambient
1
MM4AEXRW
Exam
Reading
1
Wiring
MM4AEN
21T5S
1
Wiring
MM4ARW
14T5S
1
Ambient
Nurse
MM4AR
# LAMPS & LAMP WATTAGE/TYPE
39TT
NOTE: Styles must be specified in order:
1) Ambient 2) Exam 3) Reading.
255TT/155TT
240TT/140TT
Standard
1
2
2 or 4
254T5H/254T5H
2
2 or 4
224T5H/224T5H
Standard
2
4
2
4
2
4
2
2
2
214T5S/228T5S
2
Standard
4
4
2
2 or 4
2
2 or 4
221T5S/421T5S
Standard
4
2
2
4
2
2
1
1
1
1
1
4
4
1
2
2 or 4
2
2
2
4
4
4
2
2 or 4
1
2
2 or 4
1
2
2 or 4
1
221T5S/221T5S/
114T5S
2
2 or 4
2
221T5S/421T5S
2
2
2
2
2 or 4
1
2
2 or 4
1
2
2
255TT/455TT
255TT/455TT/
155TT
Standard
2
4
1
2
2
1
1
1
1
1
2
2 or 4
1
2
2 or 4
1
2
2 or 4
1
2
2 or 4
1
2
2 or 4
1
2
2
2
2
214T5S/221T5S/
114T5S
Standard
2
4
1
H.E. Williams, Inc.
1
1
1
Carthage, Missouri
1
2
2 or 4
1
240TT/440TT/
140TT
2 or 4
1
w w w.hew.com
417-358-4065
214T5S/421T5S/
140TT
2
Some fixture configurations do not allow all
ballasts to be located within the nurse light or
wiring compartment. Ballasts and electrical
connections will be located in primary fixture
or wiring compartment (when “W” or “+” is
specified) as space allows.
Specify using only those lamp and ballast
combinations defined in tables provided.
Healthcare
Page 1C of F
MM
MULTMED MODULAR MEDICAL BED LIGHT
CONFIGURATION/CATALOG EXAMPLES
A
B
C
D
E
F
MM4AERN
Installed Individually
MM2AE+2RN
Installed Side by Side
MM2AE+2RN
Installed Spaced Apart
or Around Equipment
MM4AEXRW
Installed Individually
NOTE: Styles must be specified in
order: 1) Ambient 2) Exam 3) Reading.
MM1N
Installed Individually
MM1N
A
2’x1’ Nurse Light
MM 1 N G
t t t t
SERIES NOM. STYLECEILING
L.TYPE
EXAMPLE
MM2RN
B
Healthcare
Page 1D of F
OPTIONS
-
UNV
t
VOLTAGE
-
-
-
2’x4’ Ambient, Exam, Reading, and Nurse Light
-
-
M M 4 AE R N G
240T T/440T T/140T T
O P TI O N S
t t
t
t
t
t
# LAMPS & LAMP WATTAGE/TYPE
OPTIONS
SERIES NOM. STYLE CEILING
L.TYPE
AMBIENT/EXAM/READING
EXAMPLE
-
E B2- E B2/2- E B1
t
BALLAST TYPE
AMBIENT-EXAM-READING
-
-
-
M M 2 AE+ 2 R N G
214T5S/414T5S/114T5S
O P TI O N S
t t t t t t
t
t
# LAMPS & LAMP WATTAGE/TYPE
OPTIONS
SERIES NOM. STYLE NOM. STYLE CEILING
L. L.TYPE
AMBIENT/EXAM/READING
EXAMPLE
t
VOLTAGE
E B2- E B2/2- E B1
t
-
UNV
t
BALLAST TYPE
AMBIENT-EXAM-READING
-
-
-
M M 2 AE+ 2 R N G
214T5S/414T5S/114T5S
O P TI O N S
t t t t t t
t
t
# LAMPS & LAMP WATTAGE/TYPE
OPTIONS
SERIES NOM. STYLE NOM. STYLE CEILING
L. L.TYPE
AMBIENT/EXAM/READING
EXAMPLE
VOLTAGE
E B2- E B2/2- E B1
t
-
UNV
BALLAST TYPE
AMBIENT-EXAM-READING
t
VOLTAGE
2’x4’ Ambient, Extended Length Exam, Reading, and Wiring Compartment
M M 2 AE XRW
t t
t
STYLE
SERIES NOM.
L.
EXAMPLE
UNV
2’x2’ Ambient and Exam Light Installed Spaced Apart with 2’x2’ Reading and Nurse Light
-
2’x2’ Ambient and Exam Light Installed Side by Side with 2’x2’ Reading and Nurse Light
MM4AEXRW
F
t
-
MM2AE + 2RN
E
O P TI O N S
M M 2 R N G
140T T
O P TI O N S
E B1
UNV
t t t t
t
t
t
t
BALLAST TYPE
VOLTAGE
SERIES NOM. STYLE CEILING # LAMPS & LAMP WATTAGE/TYPE OPTIONS
L.TYPE AMBIENT/EXAM/READING
AMBIENT-EXAM-READING
EXAMPLE
MM2AE + 2RN
D
-
2’x2’ Reading and Nurse Light
MM4AERN
C
MM2RN
Installed Individually
G
t
NOM.
L.
-
224T5H/439T5H/124T5H
t
-
O P TI O N S
t
-
E B2- E B4 - E B1
# LAMPS & LAMP WATTAGE/TYPE
OPTIONS
AMBIENT/EXAM/READING
H.E . W illiams, In c.
BALLAST TYPE
AMBIENT-EXAM-READING
C ar t hage, Mis s our i
Information contained herein is subject to change without notice.
t
-
UNV
t
VOLTAGE
w w w.he w.c om
417- 3 5 8 - 4 0 6 5
MM
MULTMED MODULAR MEDICAL BED LIGHT
PHOTOMETRY – AMBIENT ONLY
TEST REPORT INFORMATION
LUMEN SUMMARY
Test Report #: W00435.0
XX
Date: 07/16/13
XX
Lamp Type: FT50W
XX
Lamp Quantity: 2
Zone
XX
0°
45º
90º
Catalog #: MM4AERNG-250TT/450TT/150TT
90°
CANDLEPOWER DISTRIBUTION
Lumens % Lamp % Fixture
0 - 30
1225.
15.3
26.9
0 - 40
1995.
24.9
43.8
0 - 60
3552.
44.4
78.0
0 - 90
4551.
56.9
100.0
80°
Total Luminaire:
70°
0 - 180
60°
50°
4551.
56.9
100.0
Total Luminaire Optical Efficiency: 56.9%
40°
30°
0°
10°
20°
ZONAL CAVITY COEFFICIENTS
Ceiling
.80
.70
.50
Wall .70 .50 .30 .70 .50 .30 .50 .30 .10
Room Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
.68
.62
.56
.51
.47
.43
.40
.37
.34
.32
.30
.68
.59
.51
.45
.40
.36
.32
.29
.26
.24
.22
.68
.57
.48
.40
.35
.30
.27
.24
.22
.20
.18
.66
.60
.55
.50
.45
.42
.39
.36
.33
.31
.29
.66
.58
.50
.44
.39
.35
.31
.29
.26
.24
.22
.66
.56
.47
.40
.34
.30
.27
.24
.21
.19
.18
.63
.55
.48
.42
.38
.34
.30
.28
.25
.23
.22
.63
.54
.45
.39
.34
.29
.26
.23
.21
.19
.18
0°
45º
90º
Zone
90°
0 - 30
3265.
16.3
25.7
0 - 40
5448.
27.2
42.9
0 - 60
9902.
49.5
77.9
0 - 90
12707.
63.5
100.0
63.5
100.0
12707.
Total Luminaire Optical Efficiency: 63.5%
50°
40°
30°
0°
10°
83
103
89
89
103
90
78.3
217.5
317.4
387.8
409.0
374.9
292.3
167.4
33.4
93
105
92
94
107
95
88
100
89
78
88
79
66
73
66
56
61
57
45º
1649.
1616.
1537.
1363.
1208.
1055.
836.
614.
356.
60.
10.
90º
1649.
1672.
1513.
1360.
1308.
1161.
1015.
789.
382.
79.
14.
25
30
25
27
33
27
27
34
28
29
35
28
29
35
29
27
33
28
24
29
24
20
23
20
17
20
18
Catalog #: MM4AERNG-250TT/450TT/150TT
Footcandle calculations based on standard reflectance
of 80/50/20 and a light loss factor of .85 over 3’ wide
bed at a 9’ ceiling height. Values are for bed surface.
CANDLEPOWER DISTRIBUTION
Lumens % Lamp % Fixture
0 - 180
70°
60°
96
89
Catalog #: MM4AERNG-250TT/450TT/150TT
Total Luminaire:
80°
82
Zonal
Lumens
Footcandle calculations based on standard
reflectance of 80/50/20 and a light loss factor
of .85. Fixtures spaced 3’ 5” O.C. over 3’ wide bed at
a 9’ ceiling height. Values are for bed surface.
LUMEN SUMMARY
Test Report #: W00436.0
XX
Date: 07/16/13
XX
Lamp Type: FT50W
XX
Lamp Quantity: 4
0º
1649.
1665.
1549.
1374.
1200.
952.
642.
341.
194.
54.
11.
.63
.51
.41
.34
.29
.25
.22
.19
.17
.15
.14
PHOTOMETRY – EXAM ONLY
XX
0º
5º
15º
25º
35º
45º
55º
65º
75º
85º
90º
Horizontal Angle
FOOTCANDLE ESTIMATOR
Effective Floor Cavity Reflectance = .20
TEST REPORT INFORMATION
Vertical
Angle
FOOTCANDLE ESTIMATOR - AMBIENT & EXAM
Vertical
Angle
0º
5º
15º
25º
35º
45º
55º
65º
75º
85º
90º
Horizontal Angle
0º
4067.
3875.
3819.
3543.
3175.
2627.
2097.
1566.
823.
125.
30.
Zonal
Lumens
45º
4067.
3981.
3990.
3818.
3561.
3180.
2377.
1706.
898.
203.
34.
90º
4067.
3975.
4039.
4025.
3845.
3186.
2643.
1786.
919.
192.
25.
57
65
58
62
69
62
62
69
62
64
71
64
65
71
65
61
67
61
54
59
54
45
49
46
39
42
39
188.3
561.6
880.6
1104.8
1171.9
1073.8
829.3
460.2
102.5
20°
ZONAL CAVITY COEFFICIENTS
Ceiling
.80
Wall .70 .50 .30
FOOTCANDLE ESTIMATOR
.70
.50
.70 .50 .30 .50 .30 .10
Room Cavity Ratio
.76 .76 .76 .74 .74 .74
0
.69 .66 .63 .67 .65 .62
1
.63 .57 .53 .61 .56 .52
2
.57 .50 .45 .55 .49 .44
3
.52 .44 .39 .51 .43 .38
4
.48 .39 .34 .46 .39 .33
5
.44 .35 .30 .43 .35 .29
6
.41 .32 .26 .40 .32 .26
7
.38 .29 .24 .37 .29 .23
8
.35 .27 .21 .34 .26 .21
9
10 .33 .25 .19 .32 .24 .19
Effective Floor Cavity Reflectance = .20
H.E. Williams, Inc.
.71
.62
.54
.47
.42
.37
.34
.31
.28
.26
.24
.71
.60
.50
.43
.37
.33
.29
.26
.23
.21
.19
.71
.57
.46
.38
.32
.27
.24
.21
.18
.16
.15
Carthage, Missouri
Footcandle calculations based on standard
reflectance of 80/50/20 and a light loss factor
of .85. Fixtures spaced 3’ 5” O.C. over 3’ wide bed at
a 9’ ceiling height. Values are for bed surface.
w w w.hew.com
417-358-4065
Healthcare
Page 1E of F
MM
MULTMED MODULAR MEDICAL BED LIGHT
PHOTOMETRY – READING ONLY
TEST REPORT INFORMATION
Test Report #: W00434.0
XX
Date: 07/16/13
XX
Lamp Type: FT50W
XX
Lamp Quantity: 1
Zone
XX
0°
45º
90º
90°
80°
0 - 30
537.
13.4
22.4
0 - 40
915.
22.9
38.1
0 - 60
1773.
44.3
73.8
0 - 90
2403.
60.1
100.0
0 - 180
60°
50°
2403.
60.1
100.0
20°
ZONAL CAVITY COEFFICIENTS
Room Cavity Ratio
Vertical
Angle
Total Luminaire
Optical Efficiency: 60.1%
40°
30°
10°
CANDLEPOWER DISTRIBUTION
Lumens % Lamp % Fixture
Total Luminaire:
70°
0°
Catalog #: MM4AERNG-250TT/450TT/150TT
LUMEN SUMMARY
Ceiling
Wall
0
1
2
3
4
5
6
7
8
9
10
.70
.80
.50
.30
.72
.65
.58
.53
.48
.44
.40
.37
.35
.32
.30
.72
.62
.53
.46
.40
.36
.32
.29
.26
.24
.22
.72
.59
.49
.41
.35
.30
.26
.23
.21
.19
.17
0º
5º
15º
25º
35º
45º
55º
65º
75º
85º
90º
Horizontal Angle
0º
660.
659.
629.
583.
512.
415.
302.
200.
121.
35.
7.
45º
660.
669.
651.
644.
631.
576.
503.
400.
235.
41.
10.
90º
660.
645.
644.
684.
687.
679.
640.
567.
267.
43.
11.
Zonal
180º Lumens
660.
679.
31.5
628.
90.9
554. 145.7
479. 189.4
391. 215.0
283. 215.6
184. 191.0
113. 103.2
34.
20.6
7.
135º
660.
651.
648.
611.
600.
553.
470.
374.
212.
37.
10.
FOOTCANDLE ESTIMATOR
.70
.70
.50
.30
.70
.63
.57
.51
.47
.43
.39
.36
.34
.31
.29
.70
.60
.52
.45
.40
.35
.31
.28
.26
.24
.22
.70
.58
.48
.40
.34
.30
.26
.23
.21
.19
.17
.50
.50
.30
.10
.67
.58
.50
.43
.38
.34
.30
.27
.25
.23
.21
.67
.56
.46
.39
.33
.29
.25
.23
.20
.18
.17
.67
.53
.42
.34
.28
.24
.20
.18
.16
.14
.12
Effective Floor Cavity Reflectance = .20
17
21
17
15
18
15
12
15
12
13
15
12
12
13
12
10
12
11
9
10
9
7
8
7
6
7
7
Footcandle calculations based on standard
reflectance of 80/50/20 and a light loss factor
of .85. Fixtures spaced 3’ 5” O.C. over 3’ wide bed at
a 9’ ceiling height. Values are for bed surface.
OPTION DETAILS
SANI-SHIELD OPTION DETAILS
SS (Double Gasketing) –
Protective acrylic shield with double
gasket. Foam gasketing is factory-installed
continuously between door frame and
luminaire housing and between door frame
and lens.
GASKETING OPTION DETAILS
SG/MYLAR (Single Gasketing) –
Fixture to grid. Foam gasketing is factoryinstalled continuously on bottom perimeter
of unit (adjacent to T-bar). NEMA Type “F”
units feature gasketing attached to top
surface of flange trim (adjacent to ceiling
surface).
Healthcare
Page 1F of F
H.E . W illiams, In c.
C ar t hage, Mis s our i
Information contained herein is subject to change without notice.
w w w.he w.c om
417- 3 5 8 - 4 0 6 5
HEW70418JL REV.06/02/16