Corporative Portfolio
SELF-PROTECTED TRANSFORMERS
Single-phase or three-phase transformers which have protection elements against
overloads, external short circuits in the low voltage network and surges. They also
have oil immersed fuses in the high voltage side to insulate them from the electrical
network in case of internal faults.
Available for single-phase applications in capacities ranging from 5 KVA through
167,5 KVA and for three-phase applications in capacities ranging from 15 KVA
through 500 KVA with secondary voltage of 220 V and capacities of up to 1000
KVA with secondary voltage of 440 V.
Manufactured meeting: ANSI-57.12.00, IEC-76 and NTC standars.
3
Corporative Portfolio
JUNCTION ENCLOSURES
Conventional and submersible
junction enclosures manufactured
in accordance to ANSI C-57.12.25,
ANSI
C-57.12.26,
ANSI
C57.12.28, ANSI C-57.12.29, NTC
5110 and RETIE standards.
It can be used for single-phase or
three-phase applications, with 2, 3,
4, 5 or 6 junction points. Current
capacity of 200 and/or 600 A,
voltage ratings of up to 34,5
GrdY/19,92 KV and 150 KV BIL.
4
Corporative Portfolio
CONVENTIONAL SINGLE PHASE TRANSFOMERS
Manufactured in accordance to: ANSI-C57.12.00, IEC-76, NTC and RETIE
standards.
Capacities ranging from 3 KVA through 500 KVA, high voltage ratings through 34,5
KV and 200 KV BIL.
KVA
5
10
15
25
37,5
50
75
100
167
CONVENTIONAL SINGLE PHASE TRANSFORMERS 15 KV
DIMENSIONS (mm)
WEIGHT (KG)
OIL VOLUME (L)
A
B
C
84
26
480
790
630
115
30
480
845
630
146
38
520
865
665
219
51
565
900
715
306
78
660
920
810
358
81
660
935
810
459
99
760
1035
810
607
120
770
1190
810
680
160
1060
1170
950
Note: These dimensions are approximate. When buying a transformer, please ask
for the real dimensions, as they may vary.
5
Corporative Portfolio
CONVENTIONAL THREE PHASE TRANSFOMERS
Manufactured in accordance to: ANSI C-57.12.00, IEC-76, NTC and RETIE
standards. KVA ratings from 15 KVA through 5000 KVA and high voltage ratings
through 46 KV and 250 KV BIL.
CONVENTIONAL THREE PHASE TRANSFORMERS
DIMENSIONS (mm)
KVA
WEIGHT (KG)
OIL VOLUME (L)
A
B
C
D
15
165
61
730
840
590
NA
30
270
98
940
850
620
NA
45
363
129
1030
890
640
NA
75
522
190
1320
940
670
NA
112,5
575
191
1090
990
785
NA
150
757
262
1270
1090
1045
590
225
950
318
1290
1120
1105
650
300
1118
389
1340
1180
1135
680
400
1354
451
1400
1230
1215
690
500
1736
554
1520
1300
1315
720
630
1650
540
1740
1400
1270
870
750
1850
560
2030
1450
1470
1000
800
2000
580
1940
1450
1470
1000
1000
2500
760
2130
1600
1320
850
NA: (“Not Applicable”). These transformers do not have wheels, but they have pole
mounting device.
Note: These dimensions are approximate. When buying a transformer, please ask
for the real dimensions, as they may vary.
6
Corporative Portfolio
SINGLE-PHASE PAD MOUNTED TRANSFORMER
Specifications single phase pad mounted transformers (Radial Feed and Loop Feed)
DIMENSIONS (mm)
KVA
WEIGHT (KG)
OIL VOLUME (L)
A
B
C
25
458
260
940
1230
1000
37,5
480
250
940
1230
1000
50
510
235
940
1230
1000
75
625
250
1150
1230
1100
100
700
255
1150
1230
1100
167
870
260
1300
1300
1360
Note: These dimensions are approximate. When buying a transformer, please ask
for the real dimensions, as they may vary.
7
Corporative Portfolio
THREE PHASE PAD MOUNTED TRANSFORMER
Manufactured in accordance to: ANSI C-57.12.25, ANSI C-57.12.26, ANSI C57.12.28, ANSI C-57.12.29, NTC 5074 and RETIE standards.
Available in capacities through 3000 KVA (Three phase transformers) and through
500 KVA (Single phase transformers). High voltage ratings through 34,5
GrdY/19.92 KV and 150 KV BIL.
CONFIGURATION:
8
Corporative Portfolio
Note: These dimensions are approximate.
When buying a transformer, please ask for
the real dimensions, as they may vary.
SPECIFICATIONS
Voltage range up to 25 KV/ 1,2 KV D/y Connection
and 15KV/1,2 KV D/y Connection
Three phase pad mounted transformers (Radial Feed Type) 15 KV
KVA
WEIGHT (KG)
OIL VOLUME (L)
45
647
280
75
768
311
112,5
875
361
150
1000
393
225
1275
517
300
1433
569
400
1718
618
500
2965
753
630
2240
775
800
2720
905
SPECIFICATIONS
Three phase pad mounted transformers (Radial Feed Type)
KVA
WEIGHT (KG)
OIL VOLUME (L)
75
680
380
112,5
880
390
150
990
400
225
1200
450
300
1360
490
400
1730
565
500
2100
600
630
2615
990
800
3080
1065
DIMENSIONS (mm)
B
C
M
132
104
36
132
106
38
132
122
43
132
122
47
138
135
53
138
139
56
140
147
57
152
148
62
162
158
64
166
158
63
A
108
112
114
114
121
125
129
131
140
165
N
18
18
18
18
18
18
18
18
18
18
D
47
47
47
47
47
47
47
47
47
47
Voltage range up to 35 KV/1,2 KV Y/y Connection
A
121
121
121
127
127
143
143
145
156
DIMENSIONS (mm)
B
C
M
149
124
56
149
124
56
149
140
56
164
146
56
164
146
56
174
161
62
174
161
62
160
175
75
174
168
68
N
18
18
18
18
18
18
18
18
18
D
53
53
53
53
53
53
53
53
53
9
Corporative Portfolio
SPECIFICATIONS
Three phase pad mounted transformers (Loop Feed Type)
KVA
WEIGHT (KG)
OIL VOLUME (L)
45
784
385
75
909
423
112,5
1027
489
150
1164
532
225
1462
682
300
1632
746
400
1925
790
500
2199
872
630
2420
930
800
3030
1140
SPECIFICATIONS
Three phase pad mounted transformers (Loop Feed Type)
KVA
WEIGHT (KG)
OIL VOLUME (L)
45
540
335
75
680
380
112,5
880
390
150
990
400
225
1200
458
300
1360
490
400
1730
565
500
2100
600
630
2500
970
800
3050
1170
SPECIFICATIONS
Three phase pad mounted transformers (Loop Feed Type)
KVA
WEIGHT (KG)
OIL VOLUME (L)
75
680
380
112,5
880
390
150
990
400
225
1200
458
300
1360
490
400
1730
565
500
2300
1010
630
3200
1350
800
3500
1410
Voltage range up to 15 KV / 1,2 KV D/y Connection
A
125
129
131
130
136
140
144
146
155
166
DIMENSIONS (mm)
B
C
M
144
104
36
144
106
38
144
115
43
144
119
47
152
132
53
152
135
56
152
143
57
152
148
62
166
159
64
168
148
64
N
18
18
18
18
18
18
18
18
18
18
D
47
47
47
47
47
47
47
47
47
47
Voltage range up to 25 KV / 1,2 KV D/y Connection
A
141
141
141
141
151
151
151
151
160
166
DIMENSIONS (mm)
B
C
M
144
106
48
144
106
48
144
106
48
144
124
48
159
130
56
159
130
56
169
147
60
176
153
60
168
163
68
170
160
69
N
18
18
18
18
18
18
18
18
18
18
D
47
47
47
47
47
47
47
47
47
47
Voltage range up to 35 KV / 1,2 KV Y/y Connection
A
141
141
141
151
151
151
152
170
170
DIMENSIONS (mm)
B
C
M
159
124
56
159
124
56
159
140
56
174
146
56
174
146
62
184
161
62
176
158
67
184
165
74
184
177
74
N
18
18
18
18
18
18
18
18
18
Note: These dimensions are approximate. When buying a transformer, please ask
for the real dimensions, as they may vary.
D
53
53
53
53
53
53
53
53
53
10
Corporative Portfolio
DRY TYPE TRANSFORMERS
Single-phase or three-phase open winding
dry type transformers with self-extinguishing
H-class
insulation
suited
for
high
temperatures, and high voltage ratings
through 15 KV.
For voltage ratings through 1,2 KV
transformers they come with an IP20
protection enclosure included.
For voltage ratings through 15 KV no
enclosure is provided and can be
manufactured with or without electrical
shielding.
These transformers are useful for raising or lowering voltage levels, in residential,
commercial or industrial applications.
Low voltage transformers, are available in KVA ratings ranging from 1 KVA through
500 KVA. For three-phase transformers with high voltage ratings up to 15 KV are
available in capacities ranging from 75 KVA through 630 KVA.
Rymel dry transformers offer optimum efficiency, low losses level, and minimum
noise levels.
11
Corporative Portfolio
SUBMERSIBLE TRANSFORMERS
These transformers are manufactured in accordance to: ANSI C-57.12.23, ANSI
C-57.12.24, NTC 4406 and RETIE standards.
These transformers are available in capacities of up to 3000 KVA for three-phase
transformers and up to 500 KVA for single-phase transformers. High voltage rating
through 34,5 GrdY/19.92 KV and 150 KV BIL.
If the customer requires it, the tank can be made of stainless steel.
CONFIGURATION:


Radial Feed type for the end of medium voltage circuit and Loop Feed
type to continue the medium voltage circuit.
Load switch (ON-OFF) for radial feed type transformer and 4-position switch
for loop feed type transformer.
12
Corporative Portfolio
CURRENT TRANSFORMERS
Window and bar type CT´s for indoor and outdoor use,
with capacities ranging from 2.5VA through 15VA;
precision classes ranging from 0.2 s through 1.0 and
current ratings ranging from 50/5 through 4000/5.
Meet the IEC 60/85, IEC 60044-1 and NTC 2205
Standards.
SPECIFICATIONS
Service Voltage (V):
120/208; 480/277
Voltage ratings (V):
600
Class (%):
0,5 s; 0,5; 1
Installation:
Indoor or outdoor
Number of cores:
1
Load (VA):
2,5; 5; 10
100, 150, 200, 300, 400, 500, 600, 700, 800,
Primary Current (Window
900, 1000, 1200, 1500, 2000, 2500, 3000,
type) (A)
4000.
Primary Current (Bar type)
100, 150, 200, 300, 400, 500, 600, 700, 800.
(A)
Secondary Current (A):
5
Thermal Current (Ith) (A): 80 In
Dynamic Current (Id) (A): 200 In
Security Factor:
<= 5
Voltage at 60 Hz 1 minute: 3 KV
Insulation:
Thermal class type 65
Type-Model (Window
TCIV (Indoor use); TCEV (Outdoor use)
Type)
Type- Model (Bar-Type)
TCIB (Indoor use); TCEB (Outdoor use)
13
Corporative Portfolio
REPAIR SERVICE (SERVY RYMEL)
REPAIR SERVICE FOR:


Oil immersed transformers
Dry transformers
MAINTENANCE OF TRANSFORMERS ON SITE AND/OR IN OUR FACILITIES:






Washing and drying of the active part.
Dielectric oil change.
Rubber gasket change.
Tank cleaning and painting.
Electrical testing protocol.
Revision of the instrumentation.
In order to define if the maintenance is going to be made on site or in our facilities
depends on the result of a set of tests that must be periodically performed, and the
correct interpretation of such tests.
ELECTRICAL TESTS:






Megger insulation resistance.
Dielectric absorption ratio DAR.
Polarization index.
Step Voltage Testing.
Winding resistance.
Turns Ratio Test (TTR)
14
Corporative Portfolio
The visual inspection is not enough to know what is the
general condition of the transformer, for this reason the
electrical tests are required as a complement to know the
condition of the solid insulation of the transformers, as
they inevitably will deteriorate over time and its condition
will show how much remaining lifetime has the equipment.
PHYSICAL-CHEMICAL ANALYSIS:







Dielectric Breakdown Voltage. (ASTM D877)
Number of neutralization. (ASTM D974)
Interfacial Tension (ASTM D2285)
Color (ASTM D1500)
Relative Density (ASTM D1298)
Quality index
Quantitative analysis if PCB (Dexil) (USEPA Method 9079)
THERMOGRAPHIC INSPECTION:
This
technique
allows
contactless
measurement of temperature, and also the
observation of images formed by the infrared
radiation source.
This technique is applicable for high and low
voltage lines, control and power enclosures,
electrical joints, hot spots, distribution and
power transformers, electric motors, among
other applications.
15
Corporative Portfolio
SPECIAL DEVELOPMENTS:
We have venture in the development of special developments or custom made
products such as:
Current Limiting Bobbins:
Used to limit the fault currents
to 3 KA, during 2 seconds in
medium voltage (rating
through 15 KV) lines, BIL 95
KV and current ratings of 50,
100, 150 and 400 A.
Anti-theft covers (MAGLOCK):
High technology and high reliability
covers with a specially designed
stainless steel lock which provides total
adjustment between the cover and the
manhole, and avoids movement.
To remove the lock is necessary a
special tool, with a unique code
assigned to each utility company.
MAGLOCK helps to protect the
infrastructure of the utility companies
against theft, vandalism and accidents;
Round Type MAGLOCK: Covers available in polypropylene, metal and
polyconcrete.
Rectangular Type MAGLOCK R-1: Covers available in polypropylene.
16
Corporative Portfolio
Advantages:
Dust and moisture resistant.
Do not require electricity.
Do not require civil works or locksmithing for its installation.
Avoid vibrations between the cover and the ground (Less noise pollution, higher
lifetime of the cover because the material supports less fatigue stresses).
Oil immersed combined measurement transformers:
Manufactured with high class accuracy for measurement (0,2% or 0,5%) and
Voltage rating through 15 KV.
It has a front enclosure to install the
energy meter, the terminal board and
the wireless modem (If a remote
measurement system is required).
Useful as measurement equipment for
medium voltage in single or threephase applications, by means of three
or two elements method (As required
by
the
client)
using
current
transformers (CT) and potential
transformers (PT).
Current transformer (CT) specifications: Capacities ranging from 2.5VA through
15VA and current ratings ranging from 50/5 A through 4000/5 A.
Potential transformer (PT) specifications: Specially designed to obtain low losses in
both copper and iron. Capacities from 10 VA, Input voltage ratings of 13.200 V or
7.620 V and Input Voltage ratings of 120 V.
17
Corporative Portfolio
Complete measurement system transformers: This is a
completely self-protected transformer which has internal
fuses, a surge protection device (SPD) in the high voltage
and one in the low voltage.
It also has a current transformer (CT) per phase in the low
voltage connected to an energy meter.
Transmission network failure detector:
Allows the detection of presence
or absence of energy in the 13,2
KV transmission lines and
transmits the events via GPRS or
RADIO to a SCADA platform or a
WEB application.
Auto-transformers:
Equipment specially designed to raise the voltage in specific
situations where, by regulation, the voltage drops are high and
do not allow offering the required voltage to the user.