Aut. Norte, paraje el Noral. Copacabana-Antioquia, Colombia. (574) 444 04 30 - (574) 274 14 14 www.rymel.com.co 2 Corporative Portfolio SELF-PROTECTED TRANSFORMERS Single-phase or three-phase transformers which have protection elements against overloads, external short circuits in the low voltage network and surges. They also have oil immersed fuses in the high voltage side to insulate them from the electrical network in case of internal faults. Available for single-phase applications in capacities ranging from 5 KVA through 167,5 KVA and for three-phase applications in capacities ranging from 15 KVA through 500 KVA with secondary voltage of 220 V and capacities of up to 1000 KVA with secondary voltage of 440 V. Manufactured meeting: ANSI-57.12.00, IEC-76 and NTC standars. 3 Corporative Portfolio JUNCTION ENCLOSURES Conventional and submersible junction enclosures manufactured in accordance to ANSI C-57.12.25, ANSI C-57.12.26, ANSI C57.12.28, ANSI C-57.12.29, NTC 5110 and RETIE standards. It can be used for single-phase or three-phase applications, with 2, 3, 4, 5 or 6 junction points. Current capacity of 200 and/or 600 A, voltage ratings of up to 34,5 GrdY/19,92 KV and 150 KV BIL. 4 Corporative Portfolio CONVENTIONAL SINGLE PHASE TRANSFOMERS Manufactured in accordance to: ANSI-C57.12.00, IEC-76, NTC and RETIE standards. Capacities ranging from 3 KVA through 500 KVA, high voltage ratings through 34,5 KV and 200 KV BIL. KVA 5 10 15 25 37,5 50 75 100 167 CONVENTIONAL SINGLE PHASE TRANSFORMERS 15 KV DIMENSIONS (mm) WEIGHT (KG) OIL VOLUME (L) A B C 84 26 480 790 630 115 30 480 845 630 146 38 520 865 665 219 51 565 900 715 306 78 660 920 810 358 81 660 935 810 459 99 760 1035 810 607 120 770 1190 810 680 160 1060 1170 950 Note: These dimensions are approximate. When buying a transformer, please ask for the real dimensions, as they may vary. 5 Corporative Portfolio CONVENTIONAL THREE PHASE TRANSFOMERS Manufactured in accordance to: ANSI C-57.12.00, IEC-76, NTC and RETIE standards. KVA ratings from 15 KVA through 5000 KVA and high voltage ratings through 46 KV and 250 KV BIL. CONVENTIONAL THREE PHASE TRANSFORMERS DIMENSIONS (mm) KVA WEIGHT (KG) OIL VOLUME (L) A B C D 15 165 61 730 840 590 NA 30 270 98 940 850 620 NA 45 363 129 1030 890 640 NA 75 522 190 1320 940 670 NA 112,5 575 191 1090 990 785 NA 150 757 262 1270 1090 1045 590 225 950 318 1290 1120 1105 650 300 1118 389 1340 1180 1135 680 400 1354 451 1400 1230 1215 690 500 1736 554 1520 1300 1315 720 630 1650 540 1740 1400 1270 870 750 1850 560 2030 1450 1470 1000 800 2000 580 1940 1450 1470 1000 1000 2500 760 2130 1600 1320 850 NA: (“Not Applicable”). These transformers do not have wheels, but they have pole mounting device. Note: These dimensions are approximate. When buying a transformer, please ask for the real dimensions, as they may vary. 6 Corporative Portfolio SINGLE-PHASE PAD MOUNTED TRANSFORMER Specifications single phase pad mounted transformers (Radial Feed and Loop Feed) DIMENSIONS (mm) KVA WEIGHT (KG) OIL VOLUME (L) A B C 25 458 260 940 1230 1000 37,5 480 250 940 1230 1000 50 510 235 940 1230 1000 75 625 250 1150 1230 1100 100 700 255 1150 1230 1100 167 870 260 1300 1300 1360 Note: These dimensions are approximate. When buying a transformer, please ask for the real dimensions, as they may vary. 7 Corporative Portfolio THREE PHASE PAD MOUNTED TRANSFORMER Manufactured in accordance to: ANSI C-57.12.25, ANSI C-57.12.26, ANSI C57.12.28, ANSI C-57.12.29, NTC 5074 and RETIE standards. Available in capacities through 3000 KVA (Three phase transformers) and through 500 KVA (Single phase transformers). High voltage ratings through 34,5 GrdY/19.92 KV and 150 KV BIL. CONFIGURATION: 8 Corporative Portfolio Note: These dimensions are approximate. When buying a transformer, please ask for the real dimensions, as they may vary. SPECIFICATIONS Voltage range up to 25 KV/ 1,2 KV D/y Connection and 15KV/1,2 KV D/y Connection Three phase pad mounted transformers (Radial Feed Type) 15 KV KVA WEIGHT (KG) OIL VOLUME (L) 45 647 280 75 768 311 112,5 875 361 150 1000 393 225 1275 517 300 1433 569 400 1718 618 500 2965 753 630 2240 775 800 2720 905 SPECIFICATIONS Three phase pad mounted transformers (Radial Feed Type) KVA WEIGHT (KG) OIL VOLUME (L) 75 680 380 112,5 880 390 150 990 400 225 1200 450 300 1360 490 400 1730 565 500 2100 600 630 2615 990 800 3080 1065 DIMENSIONS (mm) B C M 132 104 36 132 106 38 132 122 43 132 122 47 138 135 53 138 139 56 140 147 57 152 148 62 162 158 64 166 158 63 A 108 112 114 114 121 125 129 131 140 165 N 18 18 18 18 18 18 18 18 18 18 D 47 47 47 47 47 47 47 47 47 47 Voltage range up to 35 KV/1,2 KV Y/y Connection A 121 121 121 127 127 143 143 145 156 DIMENSIONS (mm) B C M 149 124 56 149 124 56 149 140 56 164 146 56 164 146 56 174 161 62 174 161 62 160 175 75 174 168 68 N 18 18 18 18 18 18 18 18 18 D 53 53 53 53 53 53 53 53 53 9 Corporative Portfolio SPECIFICATIONS Three phase pad mounted transformers (Loop Feed Type) KVA WEIGHT (KG) OIL VOLUME (L) 45 784 385 75 909 423 112,5 1027 489 150 1164 532 225 1462 682 300 1632 746 400 1925 790 500 2199 872 630 2420 930 800 3030 1140 SPECIFICATIONS Three phase pad mounted transformers (Loop Feed Type) KVA WEIGHT (KG) OIL VOLUME (L) 45 540 335 75 680 380 112,5 880 390 150 990 400 225 1200 458 300 1360 490 400 1730 565 500 2100 600 630 2500 970 800 3050 1170 SPECIFICATIONS Three phase pad mounted transformers (Loop Feed Type) KVA WEIGHT (KG) OIL VOLUME (L) 75 680 380 112,5 880 390 150 990 400 225 1200 458 300 1360 490 400 1730 565 500 2300 1010 630 3200 1350 800 3500 1410 Voltage range up to 15 KV / 1,2 KV D/y Connection A 125 129 131 130 136 140 144 146 155 166 DIMENSIONS (mm) B C M 144 104 36 144 106 38 144 115 43 144 119 47 152 132 53 152 135 56 152 143 57 152 148 62 166 159 64 168 148 64 N 18 18 18 18 18 18 18 18 18 18 D 47 47 47 47 47 47 47 47 47 47 Voltage range up to 25 KV / 1,2 KV D/y Connection A 141 141 141 141 151 151 151 151 160 166 DIMENSIONS (mm) B C M 144 106 48 144 106 48 144 106 48 144 124 48 159 130 56 159 130 56 169 147 60 176 153 60 168 163 68 170 160 69 N 18 18 18 18 18 18 18 18 18 18 D 47 47 47 47 47 47 47 47 47 47 Voltage range up to 35 KV / 1,2 KV Y/y Connection A 141 141 141 151 151 151 152 170 170 DIMENSIONS (mm) B C M 159 124 56 159 124 56 159 140 56 174 146 56 174 146 62 184 161 62 176 158 67 184 165 74 184 177 74 N 18 18 18 18 18 18 18 18 18 Note: These dimensions are approximate. When buying a transformer, please ask for the real dimensions, as they may vary. D 53 53 53 53 53 53 53 53 53 10 Corporative Portfolio DRY TYPE TRANSFORMERS Single-phase or three-phase open winding dry type transformers with self-extinguishing H-class insulation suited for high temperatures, and high voltage ratings through 15 KV. For voltage ratings through 1,2 KV transformers they come with an IP20 protection enclosure included. For voltage ratings through 15 KV no enclosure is provided and can be manufactured with or without electrical shielding. These transformers are useful for raising or lowering voltage levels, in residential, commercial or industrial applications. Low voltage transformers, are available in KVA ratings ranging from 1 KVA through 500 KVA. For three-phase transformers with high voltage ratings up to 15 KV are available in capacities ranging from 75 KVA through 630 KVA. Rymel dry transformers offer optimum efficiency, low losses level, and minimum noise levels. 11 Corporative Portfolio SUBMERSIBLE TRANSFORMERS These transformers are manufactured in accordance to: ANSI C-57.12.23, ANSI C-57.12.24, NTC 4406 and RETIE standards. These transformers are available in capacities of up to 3000 KVA for three-phase transformers and up to 500 KVA for single-phase transformers. High voltage rating through 34,5 GrdY/19.92 KV and 150 KV BIL. If the customer requires it, the tank can be made of stainless steel. CONFIGURATION: Radial Feed type for the end of medium voltage circuit and Loop Feed type to continue the medium voltage circuit. Load switch (ON-OFF) for radial feed type transformer and 4-position switch for loop feed type transformer. 12 Corporative Portfolio CURRENT TRANSFORMERS Window and bar type CT´s for indoor and outdoor use, with capacities ranging from 2.5VA through 15VA; precision classes ranging from 0.2 s through 1.0 and current ratings ranging from 50/5 through 4000/5. Meet the IEC 60/85, IEC 60044-1 and NTC 2205 Standards. SPECIFICATIONS Service Voltage (V): 120/208; 480/277 Voltage ratings (V): 600 Class (%): 0,5 s; 0,5; 1 Installation: Indoor or outdoor Number of cores: 1 Load (VA): 2,5; 5; 10 100, 150, 200, 300, 400, 500, 600, 700, 800, Primary Current (Window 900, 1000, 1200, 1500, 2000, 2500, 3000, type) (A) 4000. Primary Current (Bar type) 100, 150, 200, 300, 400, 500, 600, 700, 800. (A) Secondary Current (A): 5 Thermal Current (Ith) (A): 80 In Dynamic Current (Id) (A): 200 In Security Factor: <= 5 Voltage at 60 Hz 1 minute: 3 KV Insulation: Thermal class type 65 Type-Model (Window TCIV (Indoor use); TCEV (Outdoor use) Type) Type- Model (Bar-Type) TCIB (Indoor use); TCEB (Outdoor use) 13 Corporative Portfolio REPAIR SERVICE (SERVY RYMEL) REPAIR SERVICE FOR: Oil immersed transformers Dry transformers MAINTENANCE OF TRANSFORMERS ON SITE AND/OR IN OUR FACILITIES: Washing and drying of the active part. Dielectric oil change. Rubber gasket change. Tank cleaning and painting. Electrical testing protocol. Revision of the instrumentation. In order to define if the maintenance is going to be made on site or in our facilities depends on the result of a set of tests that must be periodically performed, and the correct interpretation of such tests. ELECTRICAL TESTS: Megger insulation resistance. Dielectric absorption ratio DAR. Polarization index. Step Voltage Testing. Winding resistance. Turns Ratio Test (TTR) 14 Corporative Portfolio The visual inspection is not enough to know what is the general condition of the transformer, for this reason the electrical tests are required as a complement to know the condition of the solid insulation of the transformers, as they inevitably will deteriorate over time and its condition will show how much remaining lifetime has the equipment. PHYSICAL-CHEMICAL ANALYSIS: Dielectric Breakdown Voltage. (ASTM D877) Number of neutralization. (ASTM D974) Interfacial Tension (ASTM D2285) Color (ASTM D1500) Relative Density (ASTM D1298) Quality index Quantitative analysis if PCB (Dexil) (USEPA Method 9079) THERMOGRAPHIC INSPECTION: This technique allows contactless measurement of temperature, and also the observation of images formed by the infrared radiation source. This technique is applicable for high and low voltage lines, control and power enclosures, electrical joints, hot spots, distribution and power transformers, electric motors, among other applications. 15 Corporative Portfolio SPECIAL DEVELOPMENTS: We have venture in the development of special developments or custom made products such as: Current Limiting Bobbins: Used to limit the fault currents to 3 KA, during 2 seconds in medium voltage (rating through 15 KV) lines, BIL 95 KV and current ratings of 50, 100, 150 and 400 A. Anti-theft covers (MAGLOCK): High technology and high reliability covers with a specially designed stainless steel lock which provides total adjustment between the cover and the manhole, and avoids movement. To remove the lock is necessary a special tool, with a unique code assigned to each utility company. MAGLOCK helps to protect the infrastructure of the utility companies against theft, vandalism and accidents; Round Type MAGLOCK: Covers available in polypropylene, metal and polyconcrete. Rectangular Type MAGLOCK R-1: Covers available in polypropylene. 16 Corporative Portfolio Advantages: Dust and moisture resistant. Do not require electricity. Do not require civil works or locksmithing for its installation. Avoid vibrations between the cover and the ground (Less noise pollution, higher lifetime of the cover because the material supports less fatigue stresses). Oil immersed combined measurement transformers: Manufactured with high class accuracy for measurement (0,2% or 0,5%) and Voltage rating through 15 KV. It has a front enclosure to install the energy meter, the terminal board and the wireless modem (If a remote measurement system is required). Useful as measurement equipment for medium voltage in single or threephase applications, by means of three or two elements method (As required by the client) using current transformers (CT) and potential transformers (PT). Current transformer (CT) specifications: Capacities ranging from 2.5VA through 15VA and current ratings ranging from 50/5 A through 4000/5 A. Potential transformer (PT) specifications: Specially designed to obtain low losses in both copper and iron. Capacities from 10 VA, Input voltage ratings of 13.200 V or 7.620 V and Input Voltage ratings of 120 V. 17 Corporative Portfolio Complete measurement system transformers: This is a completely self-protected transformer which has internal fuses, a surge protection device (SPD) in the high voltage and one in the low voltage. It also has a current transformer (CT) per phase in the low voltage connected to an energy meter. Transmission network failure detector: Allows the detection of presence or absence of energy in the 13,2 KV transmission lines and transmits the events via GPRS or RADIO to a SCADA platform or a WEB application. Auto-transformers: Equipment specially designed to raise the voltage in specific situations where, by regulation, the voltage drops are high and do not allow offering the required voltage to the user.