Three-Phase Pad-Mounted Transformer Features Howard Industries liquid-filled three-phase pad-mounted transformers are an excellent choice for any commercial or industrial underground distribution system. Typical applications include manufacturing facilities, refineries, office buildings, schools, hospitals, restaurants, warehouses, and retail stores. All Howard Industries transformers are designed, built, and tested in an ISO-9001 certified facility in accordance with applicable industry standards. Howard three-phase pad-mounted transformers are available in capacities from 30 to 10000 kVA, with high-voltage ratings from 2400 through 34500, and low-voltage ratings from 208Y/120 through 8600. All designs feature fully enclosed tamper resistant terminal compartments and can be supplied with dead-front or live-front construction (Space-Saver 3TM style available with dead-front construction only), for radial or loop feed applications. A wide range of features and accessories is available to satisfy almost any special requirement, including fuses, surge arresters, gauges, controls, cooling fans, pressure relief devices, load-break switches, and high-voltage tap switches. In addition to the standard mineral oil, alternate insulation fluids such as R-Temp, silicone, and seedbased vegetable oil are available for special applications. Standard Features and Accessories • Meets or exceeds current ANSI, NEMA, and RUS standards as applicable (except for certain dimensional characteristics of the Space-Saver 3TM design) • Full compliance with ANSI C57.12.28 enclosure integrity standards • Externally clamped universal high-voltage bushing wells for dead front applications (three for radial feed operation or six for loop feed operation) • Externally clamped lowvoltage bushings with threaded stud for fullload current through 1400 Amps, or externally clamped one-piece NEMA spade bushings for full-load current above 1400 Amps • Front panel accessory mounting brackets (dead-front construction only) • Removable neutral ground strap in low- voltage compartment (for wye connected lowvoltage ratings only) • Removable high-voltage /low-voltage neutral link, internally mounted and accessible through tamper-resistant hand hole (Wye-Wye units only) • Lifting provisions • Jacking/rolling provisions (Compartmental style only) • Removable terminal compartment and bottom sill, and removable doors with stainless steel hinges (Compartmental style only) • Removable hood with stainless steel hinges, and removable sill with stainless steel fasteners (Space-Saver 3TM only) • Bolted hand hole on oil compartment top with tamper-resistant security cover (Compartmental style only) • Three-point door latching system with recessed interlocking pentahead security bolt, and padlock provision (Compartmental style only) • Recessed hood latching system with captive pentahead security bolt, floating nut, and interlocking padlock provision (Space-Saver 3TM only) • Tank ground provisions • Mild steel tank and terminal compartment construction • Mild steel high-voltage /low-voltage compartment barrier (Compartmental style only) • Insulated high-voltage/ low-voltage compartment barrier (SpaceSaver 3TM only) • Domed top surfaces on tank and terminal compartment to prevent water retention • Recessed tank compartment bottom • Electrostatically applied powder paint finish with olive-green polyurethane top coat (Munsell 7GY 3.29/1.5) provides excellent resistance to chipping, fading, abrasion, and corrosion • Oil fill/oil level plug • Automatic pressure relief device mounted in terminal compartment • Oil drain valve with sampling device (Compartmental style only) • Electrical grade mineral oil insulation fluid with oxidation inhibitor • Laser engraved anodized aluminum nameplate • Decal bushing designations Standard KVA and Voltage Ratings Dead Front Compartmental Style KVA Ratings (65° Rise, ONAN) 45, 75, 112.5, 150, 225, 300, 500, 750, 1000, 1500, 2000, 2500, 3000, 3750, 5000, 7000, 7500, 10000 High-Voltage Ratings (Delta or Wye) 2400 through 34500 (through 150 kV BIL) Low-Voltage Ratings (Delta or Wye) 120 through 8600 or 14400Y (through 110 kV BIL) Space-Saver 3TM KVA Ratings (65° Rise, ONAN) 30, 45, 75, 112.5, 150 High-Voltage Ratings (Delta or Wye) 2400 through 34500 (through 150 kV BIL) Low-Voltage Ratings (Delta or Wye) 120 through 480 (through 30 kV BIL) Live Front Compartmental Style KVA Ratings (65° Rise, ONAN) 45, 75, 112.5, 150, 225, 300, 500, 750, 1000, 1500, 2000, 2500, 3000, 3750, 5000, 7000, 7500, 10000 High-Voltage Ratings (Delta or Wye) 2400 through 34500 (through 200 kV BIL) Low-Voltage Ratings (Delta or Wye) 120 through 8600 or 14400Y (through 110 kV BIL) (Note: Certain combinations of kVA, high-voltage, and low-voltage ratings may not be available. Contact your distributor for availability of other kVA sizes,voltage ratings, features, accessories, and design standards not listed.) Optional Features, Accessories, and Design Standards As an Energy Star Partner, Howard Industries has determined that its optional “Energy Star Compliant” transformers meet the Energy Star guidelines for energy efficiency. Howard Industries is a charter member of the Energy Star Transformer Program. • Loadbreak high-voltage bushing inserts or externally clamped integral (one piece) highvoltage bushings for dead-front applications • Externally clamped porcelain high-voltage bushings with eyebolt connectors for live-front applications (not available on Space-Saver 3TM) • Low-voltage connectors, including various screwon or slip-on types • Insulated interphase barriers (Compartmental style, live-front construction only) • Lightning arrester mounting provisions (Compartmental style, live-front construction only) • Externally operable nonloadbreak high-voltage tap switch with one of the following tap ranges: four 2.5% taps above normal; or four 2.5% taps below normal; or two 2.5% taps above and two 2.5% taps below normal; or taps at 13800/13200/12870/ 12540 for transformers with a nominal highvoltage rating of 14400 (may not be available in combination with dual high-voltage switch) • Externally operable dual high-voltage switch (may not be available in combination with highvoltage tap switch) • Fault indicators or fault indicator mounting provisions only • Internal expulsion fuses, alone or in combination with internal backup current limiting fuses • Draw-out expulsion fuses with isolation links, alone or in combination with internal backup current limiting fuses • Draw-out full-range current limiting fuses in dry-well canisters; with or without interlocking loadbreak switch (Compartmental style only) • Internal full-range current limiting fuses (Compartmental style only) • Arc Strangler® fused disconnect switches (Compartmental style, live-front construction only) • MOV surge arresters, including under-oil, elbow, or panel-mounted types (panel-mounted types are available on compartmental live-front units only) • Drip shields for use with draw-out expulsion fuses • Externally operable twoposition or four-position high-voltage loadbreak switch • Internal low-voltage circuit breaker with external operating handle, or external molded case low-voltage circuit breakers (Compartmental style only) • High capacity pressure relief device mounted on tank cover (Compartmental style only) • Drain valve with sampling device • Total stainless steel or hybrid (mild steel/ stainless steel) construction • Temporary access service provision (conduit hole) • Hexhead security bolt (pentahead standard) • External Watt-hour meter base with or without meter, or mounting provisions only(Compartmental style, live-front construction only) • External potential transformers • External current transformers • Tank ground connectors • Cover mounted throat for bus duct connection (Compartmental style only) • Dial type temperature gauge • Dial type liquid level gauge • Dial type pressure/ vacuum gauge • Cooling fans or fan mounting provisions only (Compartmental style only) • R-Temp, silicone or seedbased vegetable oil insulation fluid • Laser engraved stainless steel nameplate (aluminum standard) • Custom stenciling or labeling • NEMA safety labels • Energy efficient amorphous metal cores (available through 750 kVA only) • Compliance with Canadian Standards Association (CSA) standards or other nonU.S. standards (Note: Contact your distributor or factory representative for availability of other kVA sizes, voltage ratings, features, accessories and design standards not listed.) Arc Strangler® is a registered trademark of Cooper Power Systems. Howard Industries Distribution Transformers are Available in a Complete Range of Types, Sizes and Voltage Ratings. Single-Phase Pole-Mounted Three-Phase Pole-Mounted Single-Phase Pad-Mounted Single-Phase Subsurface Available in capacities ranging from 0.5 through 833 kVA. Voltage ratings through 19.9/34.5 kV, 200 kV BIL. Refer to Bulletin 1001 Available in capacities ranging from 30 through 150 kVA. Voltage ratings through 34.5/19.9 kV, 150 kV BIL. Refer to Bulletin 1001 Available in capacities ranging from 10 through 333 kVA. Voltage ratings through 19.9/34.5 kV, 150 kV BIL. Refer to Bulletin 1002 Available in capacities ranging from 10 through 250 kVA. Voltage ratings through 19.9/34.5 kV, 150 kV BIL. Refer to Bulletin 1003 Three-Phase Substation Three-Phase Pad-Mounted Available in capacities ranging from 112.5 through 10,000 kVA. Voltage ratings through 69 kV, 350 kV BIL. Refer to Bulletin 1004 Available in capacities ranging from 30 through 10,000 kVA. Voltage ratings through 34.5/19.9 kV, 200 kV BIL. Refer to Bulletin 1005