Analog Devices Energy Metering Products x 5 7 7 AD Energy Metering IC’s Quality you can trust. http://www.analog.com/energymeter/ a Analog Devices Superior Quality All integrated circuits (IC) manufactured by Analog Devices endure a strict qualification process to ensure high quality of our end products. Extensive qualification processes are carried out in fabrication, assembly and endproduct stages. To ensure consistent quality of our products, production samples are constantly drawn for reliability testing and failure analysis. Additionally, the results provided by our world-class Products Analysis Group on customer returns and device qualification failures help trigger continuous product/process improvements worldwide. LIST OF QUALIFICATIONS CORPORATE STANDARD QUALIFICATIONS SUPPLEMENTAL QUALIFICATIONS Fabrication Qualification Customer Feedback Passed Production Quality Control Assembly Qualification Application Specific Qualification Passed End-Product Qualification · · · · · · · · Time dependent dielectric breakdown Electromigration Hot carrier injection Electrical endurance – HTOL & LTOL Early life failure characterization High temperature storage Moisture endurance test Die shear test · · · · · · · · · · · · · · · · · · · Bond strength Burn-in sequence Constant acceleration Hermeticity High temperature storage Internal water vapor test Lead fatigue Lid torque Marking permanency Mechanical shock Moisture sensitivity characterization Moisture endurance sequence & autoclave Resistance to soldering heat Solderability Thermal impedance Thermal shock sequence Temperature cycling sequence Vibration, variable frequency X-ray Inspection · Fabrication & assembly qualification · Electrical static discharge (ESD) · Latch up Did You Know? Analog Devices regularly performs tests that are tailored to our products’ specific applications. For example, to answer our customers’ question on the expected lifespan of solid-state energy meters, our AD7755 was tested and passed 3,000 hours accelerated life test (HTOL to 125°C), an equivalence of 60 years lifespan! This study clears misconceptions that a solid-state energy meter IC might have a short expected lifespan. a Visit our website for samples, datasheets, and additional product information. The qualification process is simply the very first step taken to ensure our quality and reliability. To ensure our products meet the highest quality standard, Analog Devices constantly monitors the finished products. The plot below shows the quarterly failure rate in parts per million (ppm). Please note that the electrical ppm failure is largely comprised of marginal parametric rejects. In other words, these rejects are fully functional but are more likely to experience early failure in the field. As you can see, the consistent rate reflects the stability of our process. The low ppm rate also directly reflects the quality of the products our customers received. The low failure ppm ensures the products our customers receive have virtually zero defects and low probability of early failure in the field. Analog Devices’ Product Analysis Group works directly with customers on quality issues and provide rapid responses to customers through correlation, analysis and corrective actions. Quar terly Electrical Outgoing PPM Results & $ " & $ " 3'& !3'& "3'& 3'' 3'' !3'' "3'' 3 3 Did You Know? The quality of the product you receive depends on the overall failure rate of the lot that the part comes from. The lower the failure rate of the lot, the better the quality of the product. The consistently low failure rate from Analog Devices’ manufacturing process shows the reliability of our products. For the latest ppm data, as well as further details on Analog Devices’ quality system, visit the Quality Systems link in our corporate web site at http://www.analog.com/. Analog Devices Energy Measurement Performance AD7755 is the core of our AD775x family and is the product of choice for many meter manufacturers around the world. It provides unsurpassed accuracy of watt calculation over a very wide dynamic range. The plots below highlight the performance of AD7755 over a dynamic range of 1000:1 and temperature range of –40°C to 85°C. Even at low power factor (PF=0.5), as shown on the plot on the right, AD7755 maintains its accuracy. 0.5 0.4 0.4 - 40 ⴗC - 40 ⴗC PF = 0.5 0.2 0.3 0.1 PF = 1 GAIN = 16 ON-CHIP REFERENCE 0.0 +25 ⴗC PF = 1 % ERROR % ERROR 0.2 +25 ⴗC 0.0 -0.1 -0.2 +85 ⴗC -0.2 +25 ⴗC PF = 0.5 -0.4 +85 ⴗC PF = 0.5 -0.6 -0.3 -0.8 -0.4 -0.5 0.01 0.1 1 Amps 10 100 -1.0 0.01 PF = 0.5 GAIN = 16 ON-CHIP REFERENCE 0.1 http://www.analog.com/energymeter/ 1 Amps 10 100 a Another main reason why many manufacturers choose AD7755 is its ease of use. A single calibration point, typically at Ib (basic current), is all that is needed to calibrate the meter. The AD7755 needs a single 5V voltage supply, and it provides direct drive capability to a mechanical counter. The AD7755 can also interface with very low resistance shunt. The circuitry needed for a meter is very simple. Shown on the right is our solid-state watt-meter reference design. The full documentation of this meter, Application Note AN-559, can be found in our web site. The reference design is provided to help our customer shorten the design cycle. Please visit our web site for further details. Energy Measurement ICs: Now and the Future Product Introductions Vs. Integrated Circuit Functionality 3 Phase Multiple Function a ADSP2185L a a AD73360L AD7758 a AD73360 a ADuC812SBRU a 3 Phase Watts ADuC812 ADSPADSP- 2185L Single chip 3.3V DSP Microcomputer AD73360 Six 16 bit Σ−∆ ADCs AD73360L Low power AD73360 AD7758 AD7754 + Reactive Power ADuC812 8ch, 12 bit ADC, Flash, 8052 ADuC812SBRU ADuC812 Pin Count Reduction a AD7754 AD7756 with Six Input Channels AD7754 a 1 Phase MCU-Based Design AD7753 1 Phase Single Chip Design a a AD7756 AD7759 a a AD7751 AD7752 AD7756 AD7755 with SPI(Serial Port Interface) AD7759 AD7756 with di/dt Input AD7753 AD7756 + Reactive Power A D7755 Core AD775X product with Motor Drive AD7751 AD7755 + Fault Tolerance a a a AD7757 AD7755 + Integrated Oscillator AD7750 AD7755 AD7757 AD7752 AD7751 + Digital Calibration PrePre-2001 2001 PostPost-2001 a Released a Sample Introduction WORLDWIDE HEADQUARTERS One Technology Way, P.O. Box 9106 • Norwood, MA 02062-9106, U.S.A. Tel: (781) 461-3060 • Fax: (781) 461-4360 • World Wide Web Site: http://www.analog.com JAPAN HEADQUARTERS New Pier Takeshiba, South Tower Building 1-16-1 Kaigan, Minato-ku, Tokyo 105-6891, Japan Tel: 81-3-5402-8200 Fax: 81-3-5402-1063 a EUROPE HEADQUARTERS Am Westpark 1-3 D-81373 Munchen, Germany Tel: 49-89-76903-0 Fax: 49-89-76903-157 SOUTHEAST HEADQUARTERS 4501 Nat West Tower, Times Square Causeway Bay, Hong Kong Tel: (852) 2506-9336 Fax: (852) 2506-4755 Visit our website for samples, datasheets, and additional product information. 10/00