Rubber Cord Cord & Cordset Super Vu-Tron® Supreme Types SJOOW/SOOW 105ºC 300 and 600 Volt UL /CSA Portable Cord N PRO EW DUC T Product Construction: Conductors: • 18 through 10 AWG. fully annealed stranded tinned copper per ASTM B-174 Insulation: • Premium-grade, color-coded, oil-resistant 105ºC EPDM • Color Code: See chart below TYPE SJOOW – 300 VOLT – UL/CSA APPROX. NO. NET WT. COPPER CATALOG OF AWG. COND. STRAND CURRENT LBS/ WT. STD. † NUMBER COND. SIZE STRAND O.D. INCHES mm INCHES mm AMPS M' (S) LBS/M' CTN. NOM. INS. JACKET THICKNESS NOMINAL O.D. 02601 02602 02603 2 3 4 18 18 18 41/34 41/34 41/34 .048" 0.030 0.76 0.310 .048" 0.030 0.76 0.320 .048" 0.030 0.76 0.345 7.87 8.13 8.76 10 10 7 60 70 85 10 15 20 1000' 1000' 250' 02604 02605 02606 2 3 4 16 16 16 65/34 65/34 65/34 .061" 0.030 0.76 0.315 8.00 .061" 0.030 0.76 0.335 8.51 .061" 0.030 0.76 0.370 9.40 13 13 10 67 83 100 16 24 32 1000' 250' 250' 02607 02608 02609 2 3 4 14 105/34 .078" 0.030 0.76 0.370 9.40 14 105/34 .078" 0.030 0.76 0.375 9.53 14 105/34 .078" 0.030 0.76 0.405 10.29 18 18 15 90 114 132 26 41 55 250' 250' 250' TYPE SOOW – 600 VOLT – UL/CSA NO. CATALOG OF AWG. COND. NUMBER COND. SIZE STRAND NOM. INS. THICKNESS APPROX. NET WT. COPPER CURRENT LBS/ WT. STD. mm AMPS† M' (S) LBS/M' CTN. JACKET NOMINAL O.D. INCHES mm INCHES 02631* 02632 02633* 2 3 4 18 18 18 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.365 0.375 0.400 9.27 9.53 10.16 10 10 7 75 84 110 10 15 21 250' 250' 250' 02634 02635 02636 02621 2 3 4 5 16 16 16 16 65/34 65/34 65/34 65/34 0.030 0.030 0.030 0.030 0.76 0.76 0.76 0.76 0.370 9.40 0.395 10.03 0.425 10.80 0.515 13.08 13 13 10 8 86 105 127 181 16 24 32 40 250' 250' 250' 250' 02637* 02638 02639 02622* 2 3 4 5 14 14 14 14 105/34 105/34 105/34 105/34 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.510 12.95 0.525 13.34 0.575 14.61 0.675 17.15 18 18 15 12 155 176 218 285 26 41 55 66 250' 250' 250' 250' 02641* 02642 02643 02623* 2 3 4 5 12 12 12 12 168/34 168/34 168/34 168/34 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.590 14.99 0.600 15.24 0.650 16.51 0.730 18.54 25 25 20 16 200 243 295 315 41 67 90 103 250' 250' 250' 250' 02645 02646 02624* 3 4 5 10 10 10 259/34 259/34 259/34 0.045 0.045 0.045 1.14 1.14 1.14 *Non-stock item; minimum quantity purchase required. †G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. 0.660 16.76 0.710 18.03 0.770 19.56 30 25 20 299 413 432 99 132 168 250' 250' 250' COLOR CODE CHART NO. OF CONDUCTORS COLOR 2 3 4 5 Black, White Black, White, Green/Yellow Black, White, Red, Green/Yellow Black, White, Red, Orange, Green/Yellow Jacket: • Super Vu-Tron® Supreme, Yellow • Temperature Range: –50ºC to +105ºC UL/CSA • Voltage rating: 300 volts Type SJOOW 600 volts Type SOOW Jacket Marking: • CAROL SUPER VU-TRON SUPREME (SIZE) (mm2) 105C (UL) WATER RESISTANT SJOOW (OR SOOW) CSA (–50C) FT-1 P-123-103 MSHA 300 (OR 600) VOLT RoHS MADE IN USA Applications: • Machine tools • Power tools • Dockside power applications • Motor leads • Portable machinery • Cranes • Submersible pumps • Where water immersion is required • Severe OEM/MRO applications Features: • Yellow stripe on green conductor • Sequential footage marks • Excellent flexibility in cold temperatures • Last longer in flex applications • Integral Flexfill® • Ozone- and weather-resistant • UL Listed and CSA Certified for indoor and outdoor use • Water-resistant - can be immersed in water • Safety-colored • High heat and flame resistance • Resistant to oils, acids and chemicals • Excellent abrasion and cut resistance • Class M stranding • Tinned copper conductors - corrosion/ oxidation-resistant • Sunlight- (UV) resistant Industry Approvals: • UL Flexible Cord - UL Subject 62 • CSA Flexible Cord - C22.2-49 • MSHA Approved • RoHS Compliant • CE Mark - Sizes 10 AWG and 12 AWG SOOW • OSHA Acceptable • JC580 Packaging: • 250' (76.2 m), 500' (152.4 m), 1000' (304.8 m) • Other put-ups available on special order OSHA Acceptable Occupational Safety and Health Administration 5 Rubber Cord Cord & Cordset AV SPECAILABLE THRIUAL ORDBEY 2008 R ! Super Vu-Tron® III Types SJOOW/SOOW 105ºC 300 and 600 Volt UL /CSA Portable Cord Product Construction: Conductors: • 18 through 10 AWG fully annealed stranded bare copper per ASTM B-174 Insulation: • Premium-grade, color-coded, oil-resistant 105ºC EPDM • Color Code: See chart below TYPE SJOOW – 300 VOLT – UL/CSA Jacket: • Super Vu-Tron® III, Yellow • Temperature Range: –50ºC to +105ºC UL/CSA • Voltage rating: 300 volts Type SJOOW 600 volts Type SOOW NOMINAL INS. THICKNESS CATALOG NUMBER NO. OF COND. Jacket Marking: 02001* 02002* 02003* 2 3 4 18 18 18 41/34 41/34 41/34 • CAROL SUPER VU-TRON III (SIZE) 105C (UL) WATER RESISTANT SJOOW (OR SOOW) CSA (–50C) FT-1 P-123-103 MSHA 300 (OR 600) VOLT 02004* 02005* 02006* 2 3 4 16 16 16 02007* 02008* 02009* 2 3 4 14 14 14 Applications: • Machine tools • Power tools • Dockside power applications • Motor leads • Portable machinery • Cranes • Submersible pumps Features: • Excellent flexibility in cold temperatures • Last longer in flex applications • Integral Flexfill® • Ozone- and weather-resistant • UL Listed and CSA Certified for indoor and outdoor use • Water-resistant, sunlight- (UV) resistant • Safety-colored • High heat and flame resistance • Resistant to oils, acids and chemicals • Excellent abrasion and cut resistance Industry Approvals: • UL Flexible Cord - UL Subject 62 • CSA Flexible Cord - C22.2-49 • MSHA Approved • RoHS Compliant Packaging: • 250’ (76.2 m), 500’ (152.4 m), 1000’ (304.8 m) • Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS COLOR 2 3 4 5 Black, White Black, White, Green Black, White, Red, Green Black, White, Red, Orange, Green 6 AWG COND. SIZE STRAND INCHES NOMINAL O.D. APPROX. CURRENT NET WT. AMPS† LBS/M1(S) STD. CTN. mm INCHES mm 0.030 0.030 0.030 0.76 0.76 0.76 0.310 0.320 0.345 8.00 8.12 8.76 10 10 7 56 65 80 1000' 1000' 250' 65/34 65/34 65/34 0.030 0.030 0.030 0.76 0.76 0.76 0.315 0.335 0.370 8.00 8.51 9.40 13 13 10 68 80 95 1000' 250' 250' 41/30 41/30 41/30 0.030 0.030 0.030 0.76 0.76 0.76 0.370 0.375 0.405 9.40 9.52 10.29 18 18 15 90 110 130 250' 250' 250' TYPE SOOW – 600 VOLT – UL/CSA NOMINAL INS. THICKNESS NOMINAL O.D. APPROX. CURRENT NET WT. AMPS† LBS/M1(S) CATALOG NUMBER NO. OF COND. AWG SIZE COND. STRAND INCHES mm INCHES mm 02031* 02032* 02033* 2 3 4 18 18 18 41/34 41/34 41/34 0.030 0.030 0.030 0.76 0.76 0.76 0.365 0.375 0.400 9.27 9.53 10.16 10 10 7 75 80 110 250' 250' 250' 02034* 02035* 02036* 02021* 2 3 4 5 16 16 16 16 65/34 65/34 65/34 65/34 0.030 0.030 0.030 0.030 0.76 0.76 0.76 0.76 0.370 0.395 0.425 0.515 9.40 10.80 10.80 13.08 13 13 10 8 75 100 120 150 250' 250' 250' 250' 02037* 02038* 02039* 02022* 2 3 4 5 14 14 14 14 41/30 41/30 41/30 41/30 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.510 0.525 0.575 0.675 12.95 13.34 14.61 17.15 18 18 15 12 155 165 215 285 250' 250' 250' 250' 02041* 02042* 02043* 02023* 2 3 4 5 12 12 12 12 65/30 65/30 65/30 65/30 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 0.590 0.600 0.650 0.730 14.99 15.24 16.51 18.54 25 25 20 16 200 250 280 315 250' 250' 250' 250' 02045* 02046* 02024* 3 4 5 10 10 10 104/30 104/30 104/30 0.045 0.045 0.045 1.14 1.14 1.14 0.660 0.710 0.770 16.76 18.03 19.56 30 25 20 320 375 432 250' 250' 250' *Non-stock item available by special order; minimum quantity purchase required. †G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. STD. CTN. Rubber Cord Cord & Cordset Carolprene® Jacketed Type SOOW 105ºC 600 Volt UL /CSA Portable Cord Product Construction: Conductors: • 16 through 10 AWG. fully annealed stranded bare copper per ASTM B-174 Insulation: • Premium-grade, color-coded 105ºC EPDM • Color Code: See chart below Jacket: • Carolprene®, Yellow • Temperature Range: -40ºC to +105ºC TYPE SOOW – 600 VOLT – UL/CSA CATALOG NUMBER NO. OF COND. 16163 16164 16173 16174 16183 16184 16193 16194 3 4 3 4 3 4 3 4 NOMINAL INS. THICKNESS AWG. COND. SIZE STRAND INCHES mm 16 16 14 14 12 12 10 10 26/30 26/30 41/30 41/30 65/30 65/30 104/30 104/30 0.030 0.030 0.045 0.045 0.045 0.045 0.045 0.045 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.14 NOMINAL O.D. INCHES mm 0.390 0.420 0.540 0.575 0.595 0.650 0.660 0.735 9.91 10.67 13.72 14.61 15.11 16.51 16.76 18.67 Cord furnished with UL and CSA labels. *Non-stock item; minimum quantity purchase required. †G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. APPROX. CURRENT NET WT. AMPS† LBS/M' (S) 13 10 18 15 25 20 30 25 96 113 167 200 214 265 279 347 STD. CTN. 250' 250' 250' 250' 250' 250' 250' 250' Jacket Marking: • CAROL (SIZE) (mm2) 105C (UL) WATER RESISTANT SOOW CSA (-40C) FT-2 P-123-103 MSHA 600 VOLT RoHS MADE IN USA Applications: • Portable tools and equipment • Portable appliances • Small motors and associated machinery Features: • Excellent resistance to oil and moisture • Good tensile strength, elongation and aging characteristics • High flexibility • Excellent abrasion resistance • Water-resistant • UL Listed and CSA certified for indoor and outdoor use Industry Approvals: • UL Flexible Cord • CSA Flexible Cord • MSHA Approved • RoHS Compliant Packaging: • 250' (76.2 m), 1000' (304.8 m) • Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 3 4 COLOR Black, White, Green Black, White, Red, Green 7 Rubber Cord Cord & Cordset Carolprene® Jacketed Type SOOW 90ºC 600 Volt UL /CSA Portable Cord Product Construction: Conductors: • 18 through 2 AWG. fully annealed stranded bare copper per ASTM B-174 Insulation: • Premium-grade, color-coded 90ºC EPDM • Color Code: See chart below Jacket: • Carolprene®, Black • Temperature Range: -40ºC to +90ºC Jacket Marking: • CAROL (SIZE) (mm ) 90C (UL) WATER RESISTANT SOOW CSA (-40C) FT-2 P-7K-123033 MSHA 600 VOLT RoHS MADE IN USA 2 Applications: • Portable tools and equipment • Portable appliances • Small motors and associated machinery Features: • Excellent resistance to oil and moisture • Good tensile strength, elongation and aging characteristics • High flexibility • Excellent abrasion resistance • Water-resistant • UL Listed and CSA certified for indoor and outdoor use Industry Approvals: • UL Flexible Cord - Subject 62 • CSA Flexible Cord - C22.2-49 • MSHA Approved • RoHS Compliant Packaging: • 250' (76.2 m), 500' (152.4 m), 1000’ (304.8 m) • Other put-ups available on special order COLOR CODE CHART NO. OF CONDUCTORS 2 3 4 5 COLOR Black, White Black, White, Green Black, White, Red, Green Black, White, Red, Orange, Green TYPE SOOW – 600 VOLT – UL/CSA NOMINAL INS. THICKNESS AWG. COND. SIZE STRAND INCHES mm NOMINAL O.D. NO. OF COND. 02763 02769 02770 2 18 16/30 0.030 0.76 0.345 8.76 10 72 250' 3 18 16/30 0.030 0.76 0.365 9.27 10 84 250' 4 18 16/30 0.030 0.76 0.390 9.91 7 101 250' 02722 02765 02766 2 16 26/30 0.030 0.76 0.370 9.40 13 83 250' 3 16 26/30 0.030 0.76 0.390 9.91 13 103 250' 4 16 26/30 0.030 0.76 0.420 10.67 10 119 250' 02723 02762 02768 2 14 41/30 0.045 1.14 0.510 12.95 18 158 250' 3 14 41/30 0.045 1.14 0.535 13.59 18 172 250' 4 14 41/30 0.045 1.14 0.575 14.61 15 208 250' 02724 02725 02726 2 12 65/30 0.045 1.14 0.570 14.48 25 195 250' 3 12 65/30 0.045 1.14 0.595 15.11 25 229 250' 4 12 65/30 0.045 1.14 0.650 16.51 20 280 250' 02767 02728 02727 2 10 104/30 0.045 1.14 0.620 15.75 30 235 250' 3 10 104/30 0.045 1.14 0.660 16.76 30 295 250' 4 10 104/30 0.045 1.14 0.715 18.16 25 353 250' 16063 16064 16065 3 8 133/29 0.060 1.52 0.845 21.46 40 525 250' 4 8 133/29 0.060 1.52 0.960 24.38 35 676 250' 5 8 133/29 0.060 1.52 1.075 27.31 28 795 250' 16073 16074 16075 3 6 133/27 0.060 1.52 0.980 24.89 55 703 250' 4 6 133/27 0.060 1.52 1.080 27.43 45 891 250' 5 6 133/27 0.060 1.52 1.200 30.48 36 1123 250' 16083 16084 16085 3 4 133/25 0.060 1.52 1.140 28.96 70 1022 250' 4 4 133/25 0.060 1.52 1.260 32.00 60 1336 250' 5 4 133/25 0.060 1.52 1.365 34.67 48 1587 250' 16093 16094 16095* 3 2 133/23 0.060 1.52 1.330 33.78 95 1484 250' 4 2 133/23 0.060 1.52 1.460 37.08 80 1869 250' 5 2 133/23 0.060 1.52 1.580 40.13 64 2240 250' INCHES mm Cord furnished with UL and CSA labels. * Non-stock item; minimum quantity purchase required. †G reen conductor for grounding only. Ampacities based on NEC table 400.5(A). (S) Actual shipping weight may vary. 8 APPROX. CURRENT NET WT. AMPS† LBS/M' (S) CATALOG NUMBER STD. CTN. Rubber Cord Cord & Cordset Super Vu-Tron® Multi-Conductor Type SOOW 90ºC 600 Volt UL /CSA Portable Cord Product Construction: Conductors: • 18 and 16 AWG. fully annealed stranded bare copper per ASTM B-174 Insulation: • Premium-grade, color-coded 90ºC EPDM • Color Code: See chart below Jacket: • Super Vu-Tron® 90ºC, Black • Temperature Range: -40ºC to +90ºC TYPE S00W – 600 VOLT – UL/CSA Jacket Marking: • CAROL Super Vu-Tron (SIZE) (mm2) 90C (UL) WATER RESISTANT SOOW CSA (-40C) FT-2 P-7K-123033 MSHA 600 VOLT RoHS MADE IN USA CATALOG NUMBER 09805 09806 09807 09808 09810 09812 09814 09816 09818* 09820 09822* 09824 09827* 09830* Applications: • Control circuits • Tools • Heavy industrial, processing and construction equipment Features: • Extra-flexible stranding • Abrasion-resistant • Resists oils and solvents • Flame-resistant • Ozone-resistant • 90ºC rated conductors and jacket • Water-resistant • UL Listed and CSA Certified for indoor and outdoor use Industry Approvals: • UL Flexible Cord - UL Subject 62 • CSA Flexible Cord - C22.2-49 • MSHA Approved • RoHS Compliant 09605 09606 09607 09608 09609 09610 09612 09614 09616 09618* 09620 09622* 09624 09626* 09630 Packaging: • 5- through 8-conductor available on 250' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels • 9+ cond. available on long-length reels • Other put-ups available on special order COLOR CODE CHART NO. OF NO. OF COND. COLOR TRACER COND. COLOR TRACER 1 2 3 4 5 6 7 8 9 10 11 14 Black — White — Red — Green — Orange — Blue — White Black Red Black Green Black Black White Red White Green White Blue White Black Red White Red Orange Black 12 13 14 15 16 17 18 19 20 21 Blue Note: Colors repeat after 21 conductors. Black Orange Red Blue Red Red Green Orange Green NO. OF COND. NOMINAL INS. THICKNESS NOMINAL O.D. AWG. SIZE COND. STRAND INCHES mm INCHES mm 5 18 16/30 0.030 0.76 0.465 11.81 6 18 16/30 0.030 0.76 0.495 7 18 16/30 0.030 0.76 0.520 8 18 16/30 0.030 0.76 0.530 13.46 10 18 16/30 0.030 0.76 0.595 12 18 16/30 0.030 0.76 0.600 APPROX. CURRENT NET WT. (1) AMPS LBS/M' (S) 5.6 141 12.57 5.6 152 13.21 5.6 172 4.9 177 15.11 4.9 225 15.24 3.5 240 265 14 18 16/30 0.030 0.76 0.630 16.00 3.5 16 18 16/30 0.030 0.76 0.700 17.78 3.5 310 18 18 16/30 0.030 0.76 0.760 19.30 3.5 345 20 18 16/30 0.030 0.76 0.795 20.19 3.5 382 22 18 16/30 0.030 0.76 0.805 20.45 3.1 400 24 18 16/30 0.030 0.76 0.850 21.59 3.1 451 27 18 16/30 0.030 0.76 0.865 21.97 3.1 475 30 18 16/30 0.030 0.76 0.915 23.24 3.1 533 5 16 26/30 0.030 0.76 0.495 12.57 8.0 167 6 16 26/30 0.030 0.76 0.520 13.21 8.0 182 7 16 26/30 0.030 0.76 0.540 13.72 8.0 194 8 16 26/30 0.030 0.76 0.575 14.61 7.0 218 9 16 26/30 0.030 0.76 0.600 15.24 7.0 243 10 16 26/30 0.030 0.76 0.620 15.75 5.0 255 12 16 26/30 0.030 0.76 0.660 16.76 5.0 296 14 16 26/30 0.030 0.76 0.730 18.54 5.0 352 383 16 16 26/30 0.030 0.76 0.740 18.80 5.0 18 16 26/30 0.030 0.76 0.770 19.56 5.0 417 20 16 26/30 0.030 0.76 0.810 20.57 5.0 457 22 16 26/30 0.030 0.76 0.900 22.86 4.5 510 24 16 26/30 0.030 0.76 0.925 23.50 4.5 563 26 16 26/30 0.030 0.76 0.965 24.51 4.5 611 30 16 26/30 0.030 0.76 1.010 25.65 4.5 767 Values shown are for current-carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors, is NOT counted in determining current carrying capacity. Ampacities based on NEC table 400.5(A). * Non-stock item; minimum quantity purchase required. (S) Actual shipping weight may vary. (1) Rubber Cord Cord & Cordset Super Vu-Tron® Multi-Conductor Type SOOW 90ºC 600 Volt UL /CSA Portable Cord Product Construction: Conductors: • 14 through 10 AWG. fully annealed stranded bare copper per ASTM B-174 Insulation: • Premium-grade, color-coded 90ºC EPDM • Color Code: See chart below Jacket: • Super Vu-Tron® 90ºC, Black • Temperature Range: -40ºC to +90ºC TYPE S00W – 600 VOLT – UL/CSA CATALOG NUMBER NO. OF COND. AWG. SIZE 09405 09406 09407 09408 09409* 09410 09412 09414 09416 09418* 09420 09424 09428* 09430* 5 6 7 8 9 10 12 14 16 18 20 24 28 30 09205 09206 09207 09208 09209 09210 09212 09214 09216 09218* 09220 09224 09226 09227* 09228* 09230 5 6 7 8 9 10 12 14 16 18 20 24 26 27 28 30 09005 09006 09007 09008* 09010 09012 09016* 09020* 5 6 7 8 10 12 16 20 NOMINAL INS. THICKNESS mm CURRENT AMPS (1) APPROX. NET WT. LBS/M'(S) 0.645 0.710 0.710 0.760 0.830 0.820 0.855 1.000 1.030 1.100 1.120 1.260 1.330 1.335 16.38 18.03 18.03 19.30 21.08 20.83 21.72 25.40 26.16 27.94 28.45 32.00 33.78 33.91 12.0 12.0 12.0 10.5 10.5 10.5 7.5 7.5 7.5 7.5 7.5 6.7 6.7 6.0 269 317 347 430 417 427 493 601 678 720 806 1003 1080 1153 0.715 0.740 0.790 0.825 0.900 1.000 1.010 1.020 1.135 1.175 1.170 1.435 1.380 1.455 1.500 1.455 18.16 18.80 20.07 20.96 22.86 25.40 25.65 25.91 28.83 29.85 29.72 36.45 35.05 37.72 38.10 36.96 16.0 16.0 16.0 14.0 14.0 14.0 10.0 10.0 10.0 10.0 10.0 9.0 9.0 9.0 9.0 9.0 333 412 465 526 517 649 669 731 933 920 989 1273 1324 1325 1355 1492 NOMINAL O.D. COND. STRAND inCHES mm inCHES 14 14 14 14 14 14 14 14 14 14 14 14 14 14 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 41/30 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 65/30 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 10 10 10 10 10 10 10 10 104/30 104/30 104/30 104/30 104/30 104/30 104/30 104/30 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 0.770 0.875 0.900 0.935 1.020 1.070 1.230 1.325 19.56 22.23 22.86 23.75 25.91 27.18 31.24 33.66 20.0 20.0 20.0 17.5 17.5 12.5 12.5 12.5 472 565 552 682 758 871 1147 1445 Values shown are for current-carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors, is NOT counted in determining current carrying capacity. Ampacities based on NEC table 400.5(A). * Non-stock item; minimum quantity purchase required. (S) Actual shipping weight may vary. (1) Jacket Marking: • CAROL Super Vu-Tron (SIZE) (mm2) 90C (UL) WATER RESISTANT SOOW CSA (-40C) FT-2 P-7K-123033 MSHA 600 VOLT RoHS MADE IN USA Applications: • Control circuits • Tools • Heavy industrial, processing and construction equipment Features: • Extra-flexible stranding • Abrasion-resistant • Resists oils and solvents • Flame-resistant • Ozone-resistant • 90ºC rated conductors and jacket • Water-resistant • UL Listed and CSA Certified for indoor and outdoor use Industry Approvals: • UL Flexible Cord - UL Subject 62 • CSA Flexible Cord - C22.2-49 • MSHA Approved • RoHS Compliant Packaging: • 5- through 8-conductor available on 250' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels • 9+ cond. available on long-length reels • Other put-ups available on special order COLOR CODE CHART NO. OF NO. OF COND. COLOR TRACER COND. COLOR TRACER 1 2 3 4 5 6 7 8 9 10 11 Black — White — Red — Green — Orange — Blue — White Black Red Black Green Black Black White Red White Orange Black 12 13 14 15 16 17 18 19 20 21 Blue Note: Colors repeat after 21 conductors. Black Green White Blue White Black Red White Red Orange Red Blue Red Red Green Orange Green 15