GEA Tuchenhagen Hygienic Centrifugal Pumps Business Line

advertisement
GEA Tuchenhagen Hygienic Centrifugal Pumps
Business Line Hygienic Pump Technology
Catalog 2014
engineering for a better world
GEA Mechanical Equipment
Publication date: 1/1/2014
The publication of specifications, technical data and information in written or electronic form does not release the user
from the responsibility of checking for themselves all products delivered by us for suitability for the application(s)
intended. These may be subject to change without prior notification. Errors and printing errors excepted - we assume
no liability for the correctness of specifications given.
The general sales terms and conditions for GEA Tuchenhagen GmbH.
All rights reserved - copyright on all contents:
GEA Tuchenhagen GmbH
Am Industriepark 2-10, 21514 Büchen, Germany
Registered Office: Büchen, Court of Registration: Lübeck, HRB 836 SB
Management office: Dipl.-Kfm. Franz Bürmann
Sales tax identification number: DE 812589019
Example of a TP standard version
TP standard version 60 Hz, 4-poles
80 - 81
82 - 101
Performance characteristics, TPS 50 Hz
Performance characteristics, TPS 60 Hz
Example of a TPS standard version
TPS standard version 50 Hz, 2-poles
102
103
104 - 105
106 - 109
Example of a TPS standard version
TPS standard version 60 Hz, 2-poles
110 - 111
112 - 115
Options for TP and TPS series
116 - 119
Spare parts for TP and TPS series
120
Pumps - Checklist
General Sales Terms and Conditions
121
122
50 Hz
2-pole
58 - 59
60 - 79
50 Hz
4-pole
Example of a TP standard version
TP standard version 60 Hz, 2-poles
60 Hz
2-pole
36 - 37
38 - 57
60 Hz
4-pole
Example of a TP standard version
TP standard version 50 Hz, 4-poles
50 Hz
2-pole
14 - 15
16 - 35
60 Hz
2-pole
Example of a TP standard version
TP standard version 50 Hz, 2-poles
Options
5-7
8-9
10 - 11
12
13
Spare Parts
Introduction
Description of TP and TPS
Overview of centrifugal pumps
Performance characteristics, TP 50 Hz
Performance characteristics, TP 60 Hz
Standard TP
Pages
Standard TPS
Table of Contents
4
GEA Tuchenhagen
GEA Flow Components
Our Business Unit
GEA Flow Components
Our main focus is on the growth and
further strengthening of our market
position as an internationally
recognized technology leader in
components for the food,
pharmaceutical and biotechnology
industries – mainly in the business
areas of valves, pumps and cleaning
technology.
The GEA Group
Every second litre of beer brewed in the world may well have flown through
a component supplied by GEA Group. About every fourth litre of milk is
extracted or further processed with equipment produced by
GEA Group. One third of the worldwide instant coffee is produced in
GEA Group systems – with sales of more than four billion euros, the group
is one of the largest suppliers of process machinery and technology in the
world.
GEA Group comprises four segments. The GEA Flow Components business
unit is part of the GEA Mechanical Equipment segment, together with the
business units Mechanical Separation, Food Solutions and Homogenizer.
The Business Unit GEA Flow Components
consists of:
GEA Tuchenhagen in Büchen (Germany), GEA Aseptomag in Kirchberg
(Switzerland) and GEA Breconcherry in the UK as well as various locations
in the USA, Canada, China, India, Poland and France
Our four Business Lines – for erverything that flows
Hygienic Valve Technology
Cleaning Technology
GEA Tuchenhagen
GEA Breconcherry
Hygienic Pump Technology
Aseptic Valve Technology
GEA Tuchenhagen
GEA Aseptomag
5
Business Line Hygienic Pumps
Economically efficient
Our Mission
GEA Tuchenhagen products meet the growing
demand for environmentally compatible
components. Our basis for this is a
future-oriented corporate and product concept
committed to economic efficiency,
sustainability and service-orientation.
The current generation of GEA Tuchenhagen®-VARIFLOW
pumps provide users with considerable cost savings.
Sensibly rated high-efficiency motors in every dimension needed
are available to cover the typical requirements of the markets.
They enable that energy consumption is kept as low as possible,
which means a positive impact on your profitability.
Hygienic design
Carefully designed flow paths free from dead corners enable
optimum utilization of the conveying energy. The product is
conveyed evenly and gently, resulting in a higher product
quality, which provides the user with improved processing
options and distribution potentials. The cleaning requirement is
considerably reduced as far as time, water and resources are
concerned, with a positive impact on production planning and
cost accounting.
Economically
• High product quality
• Reduced consumption of energy,
water and cleaning media
• Saves time in maintenance and cleaning
6
Business Line Hygienic Pumps
Sustainable
Service-oriented
Lower consumption of energy, water and chemicals means
less load on environment and climate. For GEA Tuchenhagen
users, the future success of their business, and the continuing
acceptance of their production site this aspect will become more
and more important.
Plant designers and engineering companies appreciate the
benefits offered by GEA Tuchenhagen: they cannot only profit
from a range of highly efficient products but also use the
individually tailored engineering support available from
GEA Tuchenhagen.
On many markets, ecological criteria and the quality seals
introduced for them increasingly determine retail assortment
planning and what consumers will buy.
Users of GEA Tuchenhagen products will not only be at an
advantage due to production processes which have proven to be
environmentally friendly but also as a result of their maximum
hygiene and care when processing their products.
Maintenance service offers which protect your investment
enable that the necessary service work on GEA Tuchenhagen
components can be carried out with just minor interruptions in
production processes individually tailored to the customer’s
requirements.
This helps users to fulfil their own commitment to sustainable
working methods – the best way towards a secure future!
Sustainable
Service-orientated
• Less load on climate and environment
• Individual engineering support
• Environmental orientation production methods
• Life cycle cost calculations
• Maximum hygiene and care in product processing
• Minor production interruptions
• Tailor made service concepts
7
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps
The GEA Tuchenhagen®-VARIFLOW Centifugal Pump TP is
designed for pumping demanding media up to a viscosity of
1,000 mPas. Low flow velocities and gentle discharge of media
through the spiral housing ensure extremely gentle product
handling and high efficiency.
10 pump sizes with a capacity range of up to 210 m3/h and
pump heads of up to 90 m w.c. are available, finely tuned to the
task at hand.
Applications
• Breweries
Beer, wort, yeast, water, CIP solutions
• Dairies
Milk, cream, yoghurt, whey, brine, CIP solutions
• Food
Oils, sauces, stock, brine, flavours, ice-cream mix,
CIP solutions
• Pharmaceuticals/Cosmetics
Ultra-pure water, extracts, emulsions, WFI water, distillates
• Fields of applications TP
Conveying, circulation, pressure boosting, filling lines,
filling, emptying, filtration, evaporation, cleaning
• Fields of applications TPS
CIP solutions, tank emptying, gas conveying
The spiral housing for the TP series is made of cold-rolled steel.
This material has an excellent surface quality, which is essential
for optimum cleaning in CIP/SIP processes. Wall thicknesses of
6 mm provide high strength for critical piping configurations
and high inlet pressures.
By combining the existing TP series with an upstream screw
rotor stage a new generation of hygienic self-priming centrifugal
pumps has been created.
Technical benefits
• Operating pressure max. 16 bar
• Low NPSH value avoids early cavitation to the pump
• The pumping characteristic can be adapted to the
requirements of your system by speed control or
impeller trimming
Constructive characteristics
• Open impeller design
• All parts stainless steel, wetted components made of
1.4404 or 1.4409 (AISI 316L)
• Surface roughnesses of Ra ≤ 0.8 µm can be achieved by
mechanical treatment of the surface (higher surface
qualities on request)
• Driven by premium efficiency IE3 motors,
design type IM B35, according to IEC
Special Features
The GEA Tuchenhagen®-VARIFLOW Centrifugal Pump TPS is
a self-priming pump for viscosities of up to 500 mPas. The pump
is used for CIP return applications, for emptying tanks as well as
for conveying products containing gas.
The TPS is characterized by a low sound power level, highest
efficiency and excellent cleaning properties. The TPS series also
permits evacuation of pipes on the suction side – so that just one
pump is required for CIP return and product conveying!
8
• Gentle product handling
• Standard connection: DIN 11853-2 Hygienic flange
• Low wear part stock requirement
• Acceptance test certification 3.1 (optional)
• EHEDG approved and certified
• Sealings comply to FDA and USP Class IV
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps
Sealing according to the VARIVENT® principle
The special groove enables the seal is kept reliably in
place at all times. The shape of the groove is based on
FEM analyses. The metallic stop allows a defined
compression of the seal, ensuring gap-free sealing
against the product chamber without dead corners.
O-ring sealing between pump
housing and cover
FEM showing the seal ring in
operating mode
Centrifugal Pump TP
1
Pump cover
13
Centrifugal Pump TP
Centrifugal Pump TPS
2
Clamp connection
3
Rotor housing cover
4
Circulation pipe
5
Front rotor
6
Rotor housing
12
11
8
10
9
7
1
Centrifugal Pump TP/TPS
7
Impeller
8
Mechanical seal
9
Sealing according to VARIVENT® principle
10
Pump housing
11
One-piece lantern
12
Pump shaft without key
13
Motor
12
10
11
8
Centrifugal Pump TPS
5
4
3
7
6
9
4
2
9
9
13
GEA Tuchenhagen
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS
Program overview
non self-priming
TP 2575
20
35
36
36
40
max. pump head [m]
24
42
36
60
85
1.1 - 5.5
3.0 -15.0
1.5 - 11.0
3.0 - 15.0
5.5 - 30.0
10
19
19
19
20
max. pump head [m]
6
11
9
15
21
0.75 - 3.0
0.75 - 5.5
0.75 - 4.0
3.0 - 7.5
2-pole, 50 Hz
TP 2050
max. flow rate [m³/h]
4-pole, 50 Hz
TP 2030
max. flow rate [m³/h]
2-pole, 60 Hz
TP 1540
max. flow rate [m³/h]
4-pole, 60 Hz
TP 1020
max. flow rate [m³/h]
11
22
23
21
22
max. pump head [m]
8
15.5
13
22
31
Motor rating [kW], 4-pole 0.75 - 2.2
0.75 - 4.0
0.75 - 5.5
0.75 - 4.0
4.0 - 7.5
Impeller diameter [mm]
80 - 130
130 - 180
110 - 160
160 - 210
200 - 250
min. NPSH [m] (2,900 min-1)
1.0
1.0
1.0
1.0
1.0
1,000
1,000
1,000
1,000
1,000
Motor rating [kW], 2-pole
Motor rating [kW], 4-pole 0.75 - 3.0
24
44
44
42
48
max. pump head [m]
34
62
52
85
130
3.0 - 15.0
1.5 - 11.0
3.0 - 15.0
5.5 - 30.0
Motor rating [kW], 2-pole 1.25 - 5.5
max. viscosity [mPas]
10
GEA Tuchenhagen
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS
non self-priming
self-priming
TP 3050
TP 5060
TP 7060
TP 8080
TP 16040
TPS 2030
TPS 3050
75
75
110
120
210
32
52
65
75
74
90
49
37
64
3.0 - 22.0
5.5 - 30.0
7.5 - 30.0
11.0 - 37.0
11.0 - 45.0
2.2 - 11.0
3.0 - 22.0
36
40
55
65
100
n.a.
n.a.
16
17
19
23
12
n.a.
n.a.
0.75 - 7.5
2.2 - 7.5
2.2 - 7.5
4.0 - 7.5
3.0 - 7.5
n.a.
n.a.
85
80
120
125
240
36
69
95
110
105
130
70
52
95
3.0 - 22.0
5.5 - 30.0
7.5 - 30.0
11.0 - 45.0
11.0 - 45.0
2.2 - 11.0
3.0 - 22.0
42
45
65
75
120
n.a.
n.a.
24
24
27
34
17
n.a.
n.a.
0.75 - 7.5
2.2 - 7.5
2.2 - 7.5
4.0 - 7.5
4.0 - 7.5
n.a.
n.a.
140 - 210
155 - 225
155 - 225
180 - 250
160 - 200
110 - 160
140 - 210
0.8
0.9
1.0
1.2
3.8
0.8
0.8
1,000
1,000
1,000
1,000
1,000
500
500
11
GEA Tuchenhagen
Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP
2-pole (n = 2,900 min-1)
30
20
40
30
50
100
40
50
200
300
100
200
400
300
500
400
800 1000
500
700
USGPM
900
IGPM
100
TP 8080-2
TP 2575-2
TP 5
060-
TP 2050-2
2
50
TP
TP 1540-2
30
TP 2030-2
-2
60
70
40
TP 3050-2
TP 16040-2
20
H
[m]
TP 1020-2
10
5
4
3
50 Hz
2
1
n = 2,900 min-1
10
1
20
30
40
Q
50
100
200
300
[m3/h]
4-pole (n = 1,450 min-1)
30
20
30
20
10
40
30
50
40
100
50
200
100
TP 2575-4
TP 8080-4
TP 2050-4
TP 5
060
-4
TP
TP 3050-4
TP 1540-4
TP 16040-4
3
TP 1020-4
400
0-4
5
2
400
300
706
TP 1540-4
H
[m]
300
200
50 Hz
TP 2030-4
n = 1,450 min-1
1
1
10
20
30
40
Q [m3/h]
12
50
80
100
USGPM
IGPM
GEA Tuchenhagen
Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP
2-pole (n = 3,500 min-1)
30
20
40
30
50
40
100
50
200
300
100
400
200
300
500
800
400
500
700
1200
1000
USGPM
IGPM
150
TP 2575-2
100
TP 5060-2
TP
TP2050-2
TP
70
60
-2
80
80
-2
TP 1540-2
50
TP 3050-2
TP 2030-2
40
TP 16040-2
30
H
[m]
20
TP 1020-2
10
5
1
60 Hz
n = 3,500 min-1
1
10
20
30
50
40
70
100
200
Q [m3/h]
4-pole (n = 1,750 min-1)
30
40
20
40
30
30
25
TP 2575-4
20
TP 2050-4
50
40
100
50
200
100
300
200
400
500 600
500
300
TP 8080-4
TP 5
0604
TP 1540-4
TP 7060
TP 3050-4
10
TP 16040-4
H
[m]
5
TP 1020-4
3
TP 2030-4
60 Hz
2
1
n = 1,750 min-1
1
10
20
30
40
Q [m3/h]
13
50
100
140
USGPM
IGPM
300
GEA Tuchenhagen
Standard version, centrifugal pump type TP, 2-poles (n=2,900 min-1), 50 Hz
Standard version
2 pole/50Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 210 m3/h
Pump head
max. 90 m w.c.
TP 1020
30
20
40
30
TP 1540 bis TP8080
50
40
100
50
200
300
100
200
400
500
300
400
TP 16040
800 1000
500
700
USGPM
900
IGPM
100
TP 8080-2
TP 2575-2
TP 5
060-
TP 2050-2
2
50
TP
TP 2030-2
-2
30
60
TP 1540-2
70
40
Performance characteristics TP
TP 3050-2
TP 16040-2
20
H
[m]
TP 1020-2
10
5
4
3
2
1
n = 2,900 min-1
1
10
20
30
40
50
100
Q [m3/h]
14
200
300
GEA Tuchenhagen
Example of a standard selection
T P 0 1 0 2 0 2 5 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Standard version, for other versions see options
Designation
TP01020
2
50
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
011
5.
Code of selection characteristics
TP01020
2 = 2 pole
50 = 50 Hz
080 = 80 mm
090 = 90 mm
Motor power 011 = 1.1 kW
015 = 1.5 kW
022 = 2.2 kW
030 = 3.0 kW
040 = 4.0 kW
055 = 5.5 kW
Selected values
determined by the
pump selected
100 = 100 mm 120 = 120 mm
110 = 110 mm 130 = 130 mm
(IEC 80)
(IEC 90S)
(IEC 90L)
(IEC 100L)
(IEC 112M)
(IEC 112M)
Selection using the
characteristic curves
50 Hz
2-pole
Pos
Performence curves, centrifugal pump, TP 1020 (2-pole / 50 Hz)
H
0
10
20
30
40
50
60
70
80
USGPM
[ft] [m]
0
80
10
Ø130
24
20
η 0.25 η 0.30 η 0.35
30
η 0.40
22
70
40
60
70
IGPM
η 0.45
Ø120
η 0.50
20
60
50
Standard TP
Example
18
Impeller selection in
accordance with capacity
and pump head
Impeller diameter
Ø110
16
50
Ø100
14
40
12
Ø90
10
30
Ø80
8
20
6
50 Hz
2
0
0
Required NPSH-value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
NPSH
[ft] [m]
3.0
3.0
Ø80
Ø130
2.5
2.0
2.0
1.0
1.0
0.5
0
0
0
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Motor output selection in
accordance with capacity
and pump head
1.4
1.2
1.4
1.0
Ø130
Ø120
1.2
0.8
0.6
20
1.6
1.6
1.0
19
Q [m3/h]
[hp] [kW]
1.8
20
3.5
4.0
2.0
19
Q [m3/h]
Ø110
0.8
Ø100
0.6
Ø90
Ø80
0.4
0.4
0.2
0
0.2
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Q [m3/h]
15
Standard TPS
4
10
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 20 m³/h
Pump head
max. 24 m w.c.
Housing pressure
max. 10 bar
T P 0 1 0 2 0 2 5 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Example
Pos
Designation
Code of selection characteristics
TP01020
2
50
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
011
5.
Motor power
TP 1020
2 = 2 pole
50 = 50 Hz
080 = 80 mm
090 = 90 mm
011 = 1.1 kW
015 = 1.5 kW
022 = 2.2 kW
030 = 3.0 kW
040 = 4.0 kW
055 = 5.5 kW
TP 1020
Motor size
80
90S / 90L
100L / 112M
b
484
490
602
c**
d
390
144
425
144
474/496 154
f
285
285
335
h
352
352
403
100 = 100 mm
110 = 110 mm
(IEC 80)
(IEC 90S)
(IEC 90L)
(IEC 100L)
(IEC 112M)
(IEC 112M)
m
76
76
76
n
228
228
278
p
125
140
160
120 = 120 mm
130 = 130 mm
t*
25.5
25.5
25.5
u
92
90
112
v
125
125
125
w
82
82
85
x
14
14
14
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
16
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz
H
0
10
20
30
40
50
60
70
80
USGPM
[ft] [m]
0
80
10
Ø130
24
20
η 0.25 η 0.30 η 0.35
30
η 0.40
22
70
40
60
70
IGPM
η 0.45
Ø120
η 0.50
20
60
50
18
16
50
40
50 Hz
2-pole
Ø100
14
12
Ø90
10
30
20
Standard TP
Ø80
8
6
4
10
50 Hz
2
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Required NPSH-value
NPSH
[ft] [m]
3.0
3.0
Ø80
Ø130
2.5
2.0
2.0
1.0
1.0
0.5
0
0
0
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Required motor power
1.4
1.2
1.4
1.0
Ø130
Ø120
1.2
1.0
0.6
20
1.6
1.6
0.8
19
Q [m3/h]
[hp] [kW]
1.8
20
3.5
4.0
2.0
19
Q [m3/h]
Ø110
0.8
Ø100
0.6
Ø90
Ø80
0.4
0.4
0.2
0
0.2
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
17
Standard TPS
Impeller diameter
Ø110
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 35 m³/h
Pump head
max. 42 m w.c.
Housing pressure
max. 16 bar
T P 0 1 5 4 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01540
2
50
130
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
30
5.
Motor power
TP 1540
2 = 2 pole
50 = 50 Hz
130 = 130 mm
155 = 155 mm
175 = 175 mm
030 = 3.0 kW
040 = 4.0 kW
055 = 5.5 kW
075 = 7.5 kW
092 = 9.0 kW
110 = 11.0 kW
150 = 15.0 kW
TP 1540
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M (9.0 kW + 11 kW)
132M (15 kW)
b
608
608
608
709
709
c**
480
502
524
619
670
d
152
131.5
131.5
152
152
f
335
335
335
410
410
h
403
403
403
444
444
140 = 140 mm
160 = 160 mm
180 = 180 mm
(IEC 100L)
(IEC 112M)
(IEC 112M)
(IEC 112M)
(IEC 132M)
(IEC 132M)
(IEC 132M)
m
90
90
90
90
90
n
278
278
278
332
332
p
160
190
190
216
216
145 = 145 mm
165 = 165 mm
t*
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
150 = 150 mm
170 = 170 mm
v
140
140
140
140
140
w
85
85
85
85
85
x
42
42
42
42
42
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
18
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz
H
20
0
40
60
80
100
120
140
160
USGPM
[ft] [m]
44
0
20
40
60
80
100
IGPM
Ø180
140
40
η 0.57
Ø170
120
140
120
36
η 0.55
Ø160
32
Ø150
28
24
η 0.50
Ø130
20
η 0.45
60
η 0.40
16
η 0.35
40
12
η 0.30
8
20
50 Hz
4
0
0
0
20
5
10
15
20
25
30
35
40
Q [m3/h]
6
5
15
Ø180
Ø130
4
10
3
2
5
1
0
0
0
P
5
10
15
20
25
30
35
[hp] [kW]
40
Q [m3/h]
Standard TPS
Required NPSH-value
NPSH
[ft] [m]
6.5
8
6.0
Ø180
5.5
Required motor power
50 Hz
2-pole
Ø140
80
7
6
5.0
Ø170
4.5
Ø160
4.0
5
3.5
4
3.0
Ø150
Ø140
2.5
3
2
Ø130
2.0
1.5
1.0
1
Standard TP
Impeller diameter
100
0
5
10
15
20
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
19
25
30
35
40
Q [m3/h]
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 36 m³/h
Pump head
max. 36 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 3 0 2 5 0
1
2 3
4
5
D N N F K 0 5 0 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02030
2
50
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
015
5.
Motor power
TP 2030
2 = 2 pole
50 = 50 Hz
110 = 110 mm 120 = 120 mm
145 = 145 mm 150 = 150 mm
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
TP 2030
Motor size
90S / 90L
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M
b
494
606
606
606
707
c**
429
478
500
522
617
d
121.5
131.5
131.5
131.5
152
f
285
335
335
335
410
h
352
403
403
403
444
m
85
85
85
85
85
n
228
278
278
278
332
p
140
160
190
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
90
112
112
112
132
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
85
85
85
85
x
40
40
40
40
40
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
20
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz
H
0
20
40
60
80
100
120
140
160
USGPM
[ft] [m]
44
0
20
40
60
80
100
140
120
IGPM
140
40
η 0.30
Ø160
120
η 0.35 η 0.40 η 0.45
36
η 0.50
η 0.55
η 0.60
50 Hz
2-pole
Ø150
100
80
28
Ø140
24
Ø130
Ø120
20
16
40
Standard TP
60
Ø110
12
8
20
50 Hz
4
Required NPSH-value
0
0
0
NPSH
[ft] [m]
20
5
10
15
20
10
5
0
30
35
40
Q [m3/h]
6
5
15
25
Ø110
4
Ø160
3
2
1
0
0
P
[hp] [kW]
5
10
15
20
25
30
35
40
Q [m3/h]
Required motor power
5.0
6.0
Ø160
4.5
4.0
5.0
4.0
Ø150
3.5
Ø140
3.0
Ø130
2.5
3.0
2.0
2.0
Ø110
Ø120
1.5
1.0
1.0
0
5
10
15
20
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
21
25
30
35
40
Q [m3/h]
Standard TPS
Impeller diameter
32
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 36 m³/h
Pump head
max. 60 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 5 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02050
2
50
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 2050
2 = 2 pole
50 = 50 Hz
160 = 160 mm 170 = 170 mm
190 = 190 mm 195 = 195 mm
210 = 210 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
TP 2050
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M (9.0 kW + 11 kW)
132M (15 kW)
b
622
622
622
723
723
c**
494
516
538
633
684
d
136
136
136
156
156
f
335
335
335
410
410
h
403
403
403
444
444
m
107
107
107
107
107
n
278
278
278
332
332
p
160
190
190
216
216
180 = 180 mm
200 = 200 mm
t*
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
185 = 185 mm
205 = 205 mm
v
161
161
161
161
161
w
85
85
85
85
85
x
52
52
52
52
52
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
22
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz
[ft] [m]
250
0
0
70
75
25
η 0.40
η 0.45
0
0
Required NPSH-value
NPSH
[ft] [m]
η 0.45
Standard TP
30
η 0.45
50 Hz
10
0
5
10
15
20
25
30
35
Q [m3/h]
3
10
2.5
7.5
Ø210
Ø160
2
1.5
5
1
2.5
0.5
0
Required motor power
IGPM
η 0.52
Ø160
50
0
P
0
5
10
15
20
25
30
[kW]
10
35
Q [m3/h]
Ø210
7.5
Ø200
Ø180
5
5
0
125
η 0.50
η 0.40
2.5
USGPM
η 0.52
20
7.5
100
η 0.50
η 0.45
150
Ø170
40
10
75
Ø190
Ø175
Ø180
150
12.5
125
Ø200
50
[hp]
100
50
Ø210
60
100
50
Ø160
2.5
0
0
5
10
15
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
23
20
25
Ø190
Ø170
30
35
Q [m3/h]
Standard TPS
Impeller diameter
200
25
50 Hz
2-pole
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 40 m³/h
Pump head
max. 85 m w.c.
Housing pressure
max. 16 bar
T P 0 2 5 7 5 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02575
2
50
200
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
055
5.
Motor power
TP 2575
2 = 2 pole
50 = 50 Hz
200 = 200 mm 210 = 210 mm
225 = 225 mm 230 = 230 mm
245 = 245 mm 250 = 250 mm
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 2575
Motor size
b
112M (5.5 kW / 7.5 kW)
621
132M (9.0 kW + 11 kW) 720
132M (15 kW)
720
160L
894
200L
1,033
c**
515/537
630
681
782
908
d
138
156
156
191
200.5
f
335
410
410
640
810
h
m
n
403 124.5 278
444 107 332
444 107 332
598 124.5 412
668 124.5 472
p
190
216
216
254
318
215 = 215 mm
235 = 235 mm
t*
25.5
25.5
25.5
25.5
25.5
u
112
132
132
160
200
220 = 220 mm
240 = 240 mm
v
190
190
190
190
190
w
85
85
85
110
115
x
48.5
48.5
48.5
48.5
48.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
24
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz
H
0
20
40
60
80
100
120
140
160
180
USGPM
[ft] [m]
0
280
240
20
40
Ø250
80
Ø240
72
Ø230
60
η 0.35
80
η 0.40
100
140
120
η 0.46
η 0.46
η 0.48
56
Ø200
48
η 0.35
Standard TP
Impeller diameter
η 0.44
Ø210
200
160
IGPM
η 0.44
Ø220
64
160
50 Hz
2-pole
92
η 0.40
40
120
η 0.44
32
80
24
16
40
50 Hz
8
0
0
NPSH
[ft] [m]
10
7.5
5
10
15
20
25
30
40
35
45
Q [m3/h]
3
Ø250
Ø200
2
5
2.5
0
1
0
0
P
[hp] [kW]
5
10
15
20
25
30
35
40
45
Q [m3/h]
Required motor power
16
20
16
Ø250
14
Ø240
12
Ø230
10
12
8.0
Ø220
8
Ø210
6
Ø200
4
4.0
0
2
0
0
5
10
15
20
25
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
25
30
35
40
45
Q [m3/h]
Standard TPS
Required NPSH-value
0
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 75 m³/h
Pump head
max. 65 m w.c.
Housing pressure
max. 16 bar
T P 0 3 0 5 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP03050
2
50
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 3050
2 = 2 pole
50 = 50 Hz
140 = 140 mm 150 = 150 mm
175 = 175 mm 180 = 180 mm
195 = 195 mm 200 = 200 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
TP 3050
Motor size
100L
112M (4 kW + 5.5 kW)
112M ( 7.5 kW)
132M (9.0 kW + 11 kW)
132M (15 kW)
160L
b
618
618
618
719
719
893
c**
504
515
534
629
680
781
d
134
134
134
154
154
189
f
335
335
335
410
410
640
h
403
403
403
444
444
598
m
103
103
103
103
103
103
n
278
278
278
332
332
412
p
160
190
190
216
216
254
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
160
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
155
w
85
85
85
85
85
110
x
50
50
50
50
50
50
y*
25.5
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
26
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz
0
50
100
150
200
250
300
350
USGPM
[ft] [m]
0
250
200
50
70
Ø210
60
Ø200
100
η 0.40
150
200
η 0.61
η 0.55
η 0.50
η 0.45
η 0.40
Ø160
Ø150
30
Ø140
Standard TP
100
20
50
50 Hz
10
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
NPSH
[ft] [m]
85
6
20
Required NPSH-value
80
Q [m3/h]
Ø210
Ø140
5
15
4
3
10
2
5
1
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Q [m3/h]
P
[hp] [kW]
Required motor power
20
25
20
15
Ø210
15
Ø200
Ø190
Ø180
10
Ø170
10
Ø160
Ø150
5
5
0
Ø140
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
27
Standard TPS
Impeller diameter
η 0.60
Ø170
40
IGPM
η 0.60
Ø18
70
5
150
300
η 0.45
η 0.50 η 0.55
Ø190
50
250
50 Hz
2-pole
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 75 m³/h
Pump head
max. 75 m w.c.
Housing pressure
max. 16 bar
T P 0 5 0 6 0 2 5 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP05060
2
50
175
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
055
5.
Motor power
TP 5060
2 = 2 pole
50 = 50 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
215 = 215 mm 220 = 220
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 5060
Motor size
b
112M (5.5 kW / 7.5 kW)
622
132M (9.0 kW + 11 kW) 723
132M (15 kW)
723
160L
897
200L
1,030
c**
517/538
633
684
785
905
d
137
157
157
192
195
f
335
410
410
640
810
h
403
444
444
598
673
m
114.5
114.5
114.5
114.5
114.5
n
278
332
332
412
472
mm
mm
mm
mm
p
190
216
216
254
318
165
185
205
225
=
=
=
=
t*
27.5
27.5
27.5
27.5
27.5
165
185
205
225
mm
mm
mm
mm
u
112
132
132
160
200
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
230
230
230
230
230
w
85
85
85
110
115
x
51
51
51
52
52
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
28
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz
H
0
50
100
150
200
250
300
350
USGPM
[ft] [m]
90
0
50
80
η 0.40
Ø225
250
100
150
η 0.45
η 0.50 η 0.55
200
η 0.55
η 0.62
Ø195
η 0.50
Ø185
50
η 0.45
Ø175
150
η 0.40
Ø165
40
Ø155
100
Standard TP
30
20
50
50 Hz
10
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
Required NPSH-value
NPSH
[ft] [m]
5
15
80
85
Q [m3/h]
Ø155
Ø225
4
3
10
2
5
1
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Q [m3/h]
P
[hp] [kW]
Required motor power
30
20
Ø225
Ø215
Ø205
Ø195
25
20
15
15
Ø185
10
Ø175
Ø165
10
Ø155
5
5
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
29
Standard TPS
Impeller diameter
60
IGPM
η 0.58
Ø205
200
300
η 0.58
Ø215
70
250
50 Hz
2-pole
300
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 110 m³/h
Pump head
max. 74 m w.c.
Housing pressure
max. 16 bar
T P 0 7 0 6 0 2 5 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP07060
2
50
175
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
075
5.
Motor power
TP 7060
2 = 2 pole
50 = 50 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
220 = 220 mm 225 = 225
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 7060
Motor size
b
112M
622
132M (9.0 kW + 11 kW) 723
132M (15 kW)
723
160L
897
200L
1,030
c**
538
633
684
785
905
d
132
152
152
187
190.5
f
335
410
410
640
810
h
427
444
444
596
668
m
110
110
110
110
110
n
278
332
332
412
472
mm
mm
mm
mm
165 = 165 mm
185 = 185 mm
205 = 205 mm
p
190
216
216
254
318
t*
27.5
27.5
27.5
27.5
27.5
u
112
132
132
160
200
170 = 170 mm
190 = 190 mm
215 = 215 mm
v
230
230
230
230
230
w
85
85
85
110
115
x
56
56
56
56
56
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
30
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz
H
0
100
200
300
400
500
USGPM
[ft] [m]
0
80
70
300
400
IGPM
Ø215
η 0.65
Ø205
60
η 0.60
η 0.66
Ø195
η 0.55
Ø185
Ø175
Ø165
50
150
40
η 0.50
50 Hz
2-pole
Impeller diameter
200
η 0.50 η 0.55 η 0.60
Ø225
250
200
100
Ø155
100
30
50 Hz
10
0
0
0
10
20
30
40
50
60
70
80
90
100
110
NPSH
[ft] [m]
130
20
Ø155
5
15
Ø225
4
3
10
2
5
1
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Q [m3/h]
P
[hp] [kW]
Required motor power
30
Ø225
35
25
Ø215
30
20
Ø205
25
20
15
Ø195
Ø185
15
Ø175
10
Ø165
10
5
0
Ø155
5
0
0
10
20
30
40
50
60
70
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
31
80
90
100
110
120
Q
130
[m3/h]
Standard TPS
Required NPSH-value
120
Q [m3/h]
Standard TP
20
50
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 120 m³/h
Pump head
max. 90 m w.c.
Housing pressure
max. 16 bar
T P 0 8 0 8 0 2 5 0
1
2 3
4
5
D N N F K 1 0 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP08080
2
50
180
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
110
5.
Motor power
TP 8080
2 = 2 pole
50 = 50 Hz
180 = 180 mm
210 = 210 mm
230 = 230 mm
250 = 250 mm
110 = 11.0 kW
150 = 15.0 kW
185 = 18.5 kW
220 = 22.0 kW
300 = 30.0 kW
370 = 37.0 kW
450 = 45.0 kW
TP 8080
Motor size
132M (11 kW / 15 kW)
160L
200L
225M
b
742
916
1,050
1,076
c**
652/703
804
925
961
d
156
191
195
195
f
410
640
810
810
h
444
598
668
720
190 = 190 mm
215 = 215 mm
235 = 235 mm
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
200 = 200 mm
220 = 220 mm
240 = 240 mm
205 = 205 mm
225 = 225 mm
245 = 245 mm
132M)
132M)
160L)
160L)
200L)
200L)
225M)
m
124
124
124
124
n
332
412
472
472
p
216
254
318
356
t*
27.5
27.5
27.5
27.5
u
132
160
200
200
v
250
250
250
250
w
85
110
115
115
x
71
71
71
71
y*
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
32
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz
H
0
100
200
300
400
500
600
USGPM
[ft] [m]
0
100
200
300
400
500
IGPM
110
350
100
300
90
η 0.45
η 0.55
η 0.50
η 0.60
Ø240
η 0.60
Ø230
80
250
η 0.64
η 0.55
Ø220
70
200
η 0.66
Ø210
60
Ø200
50
Ø190
Ø180
η 0.50
150
100
Standard TP
40
30
20
50
50 Hz
10
Required NPSH-value
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Q [m3/h]
NPSH
[ft] [m]
5
15
Ø250
4
Ø180
3
10
2
5
1
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Q [m3/h]
P
Required motor power
[hp] [kW]
Ø250
Ø240
40
50
40
30
Ø230
Ø220
30
Ø210
20
Ø200
Ø190
Ø180
20
10
0
10
0
0
10
20
30
40
50
60
70
80
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
33
90
100
110
120
130
140
Q
150
[m3/h]
Standard TPS
Impeller diameter
η 0.40
50 Hz
2-pole
Ø250
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 210 m³/h
Pump head
max. 49 m w.c.
Housing pressure
max. 16 bar
T P 1 6 0 4 0 2 5 0
1
2 3
4
5
D N N F K 1 5 0 1 0 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP16040
2
50
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
110
5.
Motor power
TP 16040
2 = 2 pole
50 = 50 Hz
160 = 160 mm
180 = 180 mm
200 = 200 mm
110 = 11.0 kW
150 = 15.0 kW
185 = 18.5 kW
220 = 22.0 kW
300 = 30.0 kW
370 = 37.0 kW
450 = 45.0 kW
TP 16040
Motor size
132M (11 kW / 15 kW)
160L
200L
225M
b
752
926
1,059
1,085
c**
662/713
814
934
970
d
151
186
189
189
f
410
640
810
810
h
444
596
668
720
165 = 165 mm
185 = 185 mm
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
170 = 170 mm
190 = 190 mm
175 = 175 mm
195 = 195 mm
132M)
132M)
160L)
160L)
200L)
200L)
225M)
m
108
108
108
108
n
332
412
472
521
p
216
254
318
356
t*
29.5
29.5
29.5
29.5
u
132
160
200
225
v
280
280
280
280
w
85
110
115
115
x
86
86
86
86
y*
27.5
27.5
27.5
27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
34
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz
H
0
200
100
300
400
500
600
700
900
800
[ft] [m]
0
300
200
Ø200
50
160
100
400
η 0.50 η 0.55
η 0.60
500
η 0.65
Ø190
45
140
600
700
USGPM
IGPM
η 0.67
η 0.65
50 Hz
2-pole
Ø180
120
η 0.60
35
Ø170
100
30
80
25
η 0.55
η 0.45
20
60
η 0.50
η 0.45
15
40
10
20
50 Hz
5
0
0
Required NPSH-value
0
10
20
30
40
50
60
70
80
90
NPSH
[ft] [m]
10
30
Ø200
8
20
6
4
10
Ø160
2
0
0
0
P
10
20
30
40
50
60
70
80
90
[hp] [kW
Required motor power
100 110 120 130 140 150 160 170 180 190 200 210
Q [m3/h]
12
40
45
35
40
30
35
100 110 120 130 140 150 160 170 180 190 200 210
Q [m3/h]
Ø200
25
Ø190
30
25
20
15
20
Ø180
15
Ø170
Ø160
10
10
5
0
Standard TP
Ø160
5
0
0
10
20
30
40
50
60
70
80
90
100 110 120 130 140 150 160 170 180 190 200 210
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
35
Standard TPS
Impeller diameter
40
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 4-pole (n=1,450 min-1), 50 Hz
Standard version
4 pole/50Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 100 m3/h
Pump head
max. 23 m w.c.
TP 1020
30
20
30
Performance characteristics TP
20
10
TP 1540 bis TP8080
40
30
50
40
100
50
200
100
300
200
TP 2575-4
TP 8080-4
TP 2050-4
TP 5
060
-4
TP
400
400
300
706
0-4
TP 1540-4
H
[m]
TP 16040
TP 3050-4
TP 1540-4
TP 16040-4
5
3
TP 1020-4
2
TP 2030-4
n = 1,450 min-1
1
1
10
20
30
Q
[m3/h]
36
40
50
80
100
USGPM
IGPM
GEA Tuchenhagen
Example of a standard selection
T P 0 1 0 2 0 4 5 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Standard version, for other versions see options
Designation
TP01020
4
50
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Code of selection characteristics
TP01020
4 = 4 pole
50 = 50 Hz
080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
Selected values
determined by the
pump selected
Selection using the
characteristic curves
Performance curves, centrifugal pump, TP 1020 (4-polig / 50 Hz)
H
0
5
10
15
20
25
30
35
40
USGPM
[ft] [m]
0
20
5
Ø130
6
10
η 0.25 η 0.30 η 0.35
15
η 0.40
20
35
IGPM
η 0.50
5
Impeller diameter
30
η 0.45
Ø120
Impeller selection in
accordance with capacity
and pump head
25
15
Ø110
4
10
3
Ø90
Ø80
2
1
50 Hz
0
0
1
Required NPSH-value
0
2
3
4
5
6
7
8
9
NPSH
[ft] [m]
1.5
4.0
Ø80
Ø130
1.0
3.0
2.0
0.5
1.0
0
0
0
P
1
2
3
4
5
6
7
8
9
10
Q [m3/h]
[hp] [kW]
Motor output selection in
accordance with capacity
and pump head
10
Q [m3/h]
0.3
0.2
Ø130
0.2
Ø120
Ø110
0.1
Ø100
0.1
Ø80
0
0
0
1
2
3
4
5
6
Ø90
7
8
9
10
Q [m3/h]
37
Standard TPS
5
50 Hz
4-pole
Pos
Standard TP
Example
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 10 m³/h
Pump head
max. 6 m w.c.
Housing pressure
max. 10 bar
T P 0 1 0 2 0 4 5 0
1
2 3
4
5
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01020
4
50
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 1020
4 = 4 pole
50 = 50 Hz
080 = 80 mm
100 = 100 mm
090 = 90 mm
110 = 110 mm
007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
120 = 120 mm
130 = 130 mm
TP 1020
Motor size
b
c**
d
f
h
m
n
p
t*
u
v
w
x
y*
80
484
390
144
285
352
76
228
125
25.5
92
125
82
14
25.5
90S / 90L
490
425
144
285
352
76
228
140
25.5
90
125
82
14
25.5
100L (2.2 kW / 3 kW)
602
474/489
154
335
403
76
278
160
25.5
112
125
85
14
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
38
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz
H
0
5
10
15
20
25
30
35
40
USGPM
[ft] [m]
0
20
5
Ø130
6
10
η 0.25 η 0.30 η 0.35
15
η 0,40
20
25
30
35
IGPM
η 0.45
Ø120
η 0.50
5
15
4
10
Ø90
Ø80
2
5
1
50 Hz
0
0
0
1
2
3
4
5
6
7
8
9
1.5
4.0
Ø80
Ø130
1.0
3.0
2.0
0.5
1.0
0
0
0
P
1
2
3
4
5
6
7
8
9
10
Q [m3/h]
[hp] [kW]
Required motor power
10
Q [m3/h]
0.3
0.2
Ø130
0.2
Ø120
Ø110
0.1
Ø100
0.1
Ø80
0
0
0
1
2
3
4
5
6
Ø90
7
8
9
10
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
39
Standard TPS
Required NPSH-value
NPSH
[ft] [m]
50 Hz
4-pole
3
Standard TP
Impeller diameter
Ø110
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 19 m³/h
Pump head
max. 11 m w.c.
Housing pressure
max. 16 bar
T P 0 1 5 4 0 4 5 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01540
4
50
130
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 1540
4 = 4 pole
50 = 50 Hz
130 = 130 mm 140 = 140 mm
155 = 155 mm 160 = 160 mm
175 = 175 mm 180 = 180 mm
007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
145 = 145 mm
165 = 165 mm
150 = 150 mm
170 = 170 mm
TP 1540
Motor size
b
c**
80
490
396
121.5
431
121.5
285
352
90
228
140
25.5
90
140
82
42
25.5
480/495 131.5
335
403
90
278
160
25.5
112
140
85
42
25.5
90S / 90L
496
100L (2.2 kW / 3 kW)
608
d
f
h
m
n
p
t*
u
v
w
x
y*
285
352
90
228
125
25.5
92
140
82
42
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
40
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz
H
0
10
20
30
40
50
60
70
80
USGPM
[ft] [m]
0
10
30
η 0.30 η 0.35 η 0.40 η 0.45
Ø180
11
20
40
50
60
70
IGPM
η 0.50
35
η 0.55
10
η 0.57
Ø170
30
9
Ø160
25
Ø150
7
Ø140
20
Ø130
5
Standard TP
15
4
10
3
2
5
50 Hz
1
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Required NPSH-value
NPSH
[ft] [m]
19
20
Q [m3/h]
20
5
15
4
Ø180
Ø130
3
10
2
5
1
0
0
0
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Q [m3/h]
[hp] [kW]
Required motor power
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Ø180
Ø170
Ø160
Ø150
Ø140
Ø130
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
41
50 Hz
4-pole
6
Standard TPS
Impeller diameter
8
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 19 m³/h
Pump head
max. 9 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 3 0 4 5 0
1
2 3
4
5
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02030
4
50
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 2030
4 = 4 pole
50 = 50 Hz
110 = 110 mm 120 = 120 mm
145 = 145 mm 150 = 150 mm
007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
TP 2030
Motor size
80
90S / 90L
100L (2.2 kW / 3 kW)
112M
132S
b
488
494
606
606
707
c**
394
429
478/493
500
557
d
121.5
121.5
131.5
131.5
152
f
285
285
335
335
410
h
352
352
403
403
444
m
85
85
85
85
85
n
228
228
278
278
332
p
125
140
160
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
92
90
112
112
132
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
82
85
85
85
x
40
40
40
40
40
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
42
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz
H
0
10
20
30
40
50
60
70
80
USGPM
[ft] [m]
0
10
20
30
40
50
70
60
IGPM
11
35
10
η 0.30 η 0.35 η 0.40
Ø160
30
η 0.45
9
η 0.50
η 0.55
Ø150
η 0.60
20
7
Ø140
6
Ø130
5
Ø120
4
Ø110
10
Standard TP
15
3
2
5
50 Hz
1
0
0
Required NPSH-value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
NPSH
[ft] [m]
20
3.5
4.0
3.0
3.0
Ø110
Ø160
2.5
2.0
2.0
1.0
1.0
0.5
0
0
0
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
0.8
0.6
0.7
0.5
19
20
Q [m3/h]
[hp] [kW]
Required motor power
19
Q [m3/h]
Ø160
Ø150
0.6
0.5
0.4
0.3
Ø140
0.4
Ø130
0.3
Ø120
Ø110
0.2
0.2
0.1
0
0.1
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
43
50 Hz
4-pole
25
Standard TPS
Impeller diameter
8
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 19 m³/h
Pump head
max. 15 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 5 0 4 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02050
4
50
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 2050
4 = 4 pole
50 = 50 Hz
160 = 160 mm 170 = 170 mm
190 = 190 mm 195 = 195 mm
210 = 210 mm
007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
TP 2050
Motor size
80
90S / 90L
100L (2.2 kW / 3 kW)
112M
b
504
510
622
622
c**
410
445
494/509
516
d
126
126
136
136
f
285
285
335
335
h
352
352
403
403
m
107
107
107
107
n
228
228
278
278
p
125
140
160
190
180 = 180 mm
200 = 200 mm
t*
25.5
25.5
25.5
25.5
u
90
90
112
112
185 = 185 mm
205 = 205 mm
v
161
161
161
161
w
82
82
85
85
x
52
52
52
52
y*
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
44
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz
[m]
20
60
0
20
30
10
40
20
50
30
60
40
70
50
80
Ø210
70
60
η 0.45
η 0.50
η 0.52
η 0.52
Ø190
12
η 0.50
Ø180
η 0.45
Ø170
10
Ø160
8
20
η 0.40
Ø200
14
30
η 0.45
η 0.40
6
η 0.45
4
10
50 Hz
2
0
0
NPSH
[ft] [m]
0
2.5
7.5
5
10
15
12.5
17.5
1
2.5
Ø210
Ø160
0.5
0
0
P
0
2.5
7.5
5
10
15
12.5
17.5
Required motor power
[hp] [kW]
1.5
0
20
Q [m3/h]
2.0
1.5
Ø210
1.0
1.0
0.5
20
Q [m3/h]
1.5
5
2.0
IGPM
0.5
0
Ø160
0
2.5
7.5
5
10
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
45
12.5
Ø170
Ø180
15
Ø190
Ø200
17.5
20
Q [m3/h]
50 Hz
4-pole
16
40
2.5
USGPM
Standard TP
Impeller diameter
10
18
50
Required NPSH-value
0
Standard TPS
[ft]
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 20 m³/h
Pump head
max. 21 m w.c.
Housing pressure
max. 16 bar
T P 0 2 5 7 5 4 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02575
4
50
200
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 2575
4 = 4 pole
50 = 50 Hz
200 = 200 mm 210 = 210 mm
225 = 225 mm 230 = 230 mm
245 = 245 mm 250 = 250 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
215 = 215 mm
235 = 235 mm
220 = 220 mm
240 = 240 mm
TP 2575
Motor size
b
c**
d
f
100L / 112M
621
508/515
138
335
403 124.5 278 160/190 25.5
112
190
85 48.5 25.5
132S / 132M
720
570/630
156
410
444 124.5 332
132
190
85 48.5 25.5
h
m
n
p
216
t*
25.5
u
v
w
x
y*
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
46
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz
H
0
10
20
30
40
50
60
70
90
80
USGPM
[ft] [m]
0
10
22
Ø250
20
Ø240
18
Ø230
20
30
40
50
60
70
IGPM
η 0.35
70
η 0.40
η 0.44
η 0.46
η 0.46
Ø220
η 0.44
16
Ø210
50
14
η 0.48
Ø200
Standard TP
12
40
η 0.35
10
η 0.40
30
η 0.44
8
20
6
4
10
50 Hz
2
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Q [m3/h]
1.5
4
Ø250
Ø200
1
3
2
0.5
1
0
0
0
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Q [m3/h]
Required motor power
[hp] [kW]
2.8
2.4
2.0
1.6
1.2
0.8
0.4
0
2.1
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Ø250
Ø240
Ø230
Ø200
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Ø210
17
Ø220
18
19
20
21
22
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
47
Standard TPS
Required NPSH-value
0
NPSH
[ft] [m]
50 Hz
4-pole
60
Impeller diameter
80
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 36 m³/h
Pump head
max. 16 m w.c.
Housing pressure
max. 16 bar
T P 0 3 0 5 0 4 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP03050
4
50
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 3050
4 = 4 pole
50 = 50 Hz
140 = 140 mm 150 = 150 mm
175 = 175 mm 180 = 180 mm
195 = 195 mm 200 = 200 mm
007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 3050
Motor size
80
90S / 90L
100L (2.2 kW / 3 kW)
112M
132S / 132M
b
500
506
618
618
719
c**
406
441
490/505
512
569/609
d
124
124
134
134
154
f
285
285
335
335
410
h
352
352
403
403
444
m
103
103
103
103
103
n
228
228
278
278
332
p
125
140
160
190
216
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
u
92
90
112
112
132
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
w
82
82
85
85
85
x
50
50
50
50
50
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
48
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz
0
20
40
60
80
100
120
140
160
USGPM
[ft] [m]
20
60
0
18
20
Ø210
16
η 0.40 η 0.45
η 0.55
η 0.55
14
Ø190
12
Ø180
100
η 0.60
10
IGPM
η 0.61
η 0.60
η 0.55
η 0.50
Standard TP
Ø160
30
Ø150
8
Ø140
6
η 0.45
4
10
50 Hz
2
0
0
0
NPSH
[ft] [m]
10
7.5
5
η 0.40
10
15
20
25
30
35
40
Q [m3/h]
3
Ø210
Ø140
2
5.0
2.5
0
1
0
0
P
[hp] [kW]
5
10
15
20
25
30
2.0
35
40
Q [m3/h]
Ø210
2.5
Required motor power
140
120
Ø170
20
Required NPSH-value
80
Ø200
2.0
1.5
1.5
Ø190
Ø180
1.0
Ø170
Ø160
1.0
Ø150
0.5
Ø140
0.5
0
0
0
5
10
15
20
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
49
25
30
35
40
Q [m3/h]
Standard TPS
Impeller diameter
60
Ø200
50
40
40
50 Hz
4-pole
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 40 m³/h
Pump head
max. 17 m w.c.
Housing pressure
max. 16 bar
T P 0 5 0 6 0 4 5 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP05060
4
50
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TP 5060
4 = 4 pole
50 = 50 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
215 = 215 mm 220 = 220
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 5060
Motor size
100L (2.2 kW / 3 kW)
112M
132S / 132M
b
622
622
723
c**
d
494/509 137
516
137
573/613 157
f
335
335
410
h
m
n
403 114.5 278
403 114.5 278
444 114.5 332
mm
mm
mm
mm
p
160
190
216
165
185
205
225
=
=
=
=
t*
27.5
27.5
27.5
165
185
205
225
mm
mm
mm
mm
u
112
112
132
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
230
230
230
w
85
85
85
x
51
51
51
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
50
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz
H
20
0
40
60
80
100
120
140
160
180
[ft] [m]
20
20
0
60
η 0.40 η 0.45 η 0.50 η 0.55
Ø225
60
40
80
100
120
140
USGPM
IGPM
η 0.58
Ø215
η 0.58
Ø205
Ø195
45
η 0.50
η 0.45
Ø185
Ø175
η 0.40
30
Ø155
5
15
50 Hz
0
NPSH
[ft] [m]
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0
0
5
10
15
20
25
30
35
40
Q [m3/h]
2.0
Ø225
1.5
Ø155
1.0
0.5
0
0
5
10
15
20
25
30
35
40
Q [m3/h]
P
Required motor power
[hp] [kW]
4.0
3.0
3.5
2.5
3.0
Ø225
Ø215
2.0
Ø205
2.5
2.0
1.5
1.5
1.0
Ø195
Ø185
Ø175
1.0
0.5
0
Ø155
0.5
Ø165
0
0
5
10
15
20
25
30
35
40
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
51
Standard TPS
Required NPSH-value
0
50 Hz
4-pole
Ø165
10
Standard TP
Impeller diameter
η 0.55
η 0.62
15
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 55 m³/h
Pump head
max. 19 m w.c.
Housing pressure
max. 16 bar
T P 0 7 0 6 0 4 5 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP07060
4
50
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TP 7060
4 = 4 pole
50 = 50 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
220 = 220 mm 225 = 225
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 7060
Motor size
100L (2.2 kW / 3 kW)
112M
132S / 132M
b
622
622
723
c**
d
494/509 132
516
132
573/613 152
f
335
335
410
h
427
427
444
m
110
110
110
n
278
278
332
mm
mm
mm
mm
p
160
190
216
165 = 165 mm
185 = 185 mm
205 = 205 mm
t*
27.5
27.5
27.5
u
112
112
132
170 = 170 mm
190 = 190 mm
215 = 215 mm
v
230
230
230
w
85
85
85
x
56
56
56
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
52
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz
Impeller diameter
50
Ø225
20
15
0
Required NPSH-value
8.0
2.5
6.0
2.0
Required motor power
4.5
0
1.0
0.5
0
175
275
200
USGPM
225
η 0.55 η 0.60
η 0.50
IGPM
η 0.65
η 0.60
η 0.66
η 0.55
η 0.50
50 Hz
0
5
10
15
20
25
30
35
40
45
50
55
60
65
60
65
Q [m3/h]
Ø225
Ø155
0
5
10
15
20
25
30
35
40
45
50
55
Q
[m3/h]
Ø225
3.5
2.5
1.5
250
0.5
3.5
2.0
150
225
1.0
3.0
2.5
125
200
1.5
4.0
3.0
100
175
Ø165
Ø155
P
[hp] [kW]
5.0
150
Ø175
5
3.0
0
75
Ø195
10
10.0
2.0
50
125
Ø185
NPSH
[ft] [m]
4.0
100
Ø205
10
0
75
Ø215
40
30
25
0
60
50
Ø215
Ø205
Ø195
2.0
1.5
Ø175
Ø185
Ø165
1.0
Ø155
0.5
0
0
5
10
15
20
25
30
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
53
35
40
45
50
55
60
65
Q [m3/h]
50 Hz
4-pole
20
25
Standard TP
[m]
0
Standard TPS
[ft]
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 65 m³/h
Pump head
max. 23 m w.c.
Housing pressure
max. 16 bar
T P 0 8 0 8 0 4 5 0
1
2 3
4
5
D N N F K 1 0 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP08080
4
50
180
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
040
5.
Motor power
TP 8080
4 = 4 pole
50 = 50 Hz
180 = 180 mm 190 = 190 mm
210 = 210 mm 215 = 215 mm
230 = 230 mm 235 = 235 mm
250 = 250 mm
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
200 = 200 mm
220 = 220 mm
240 = 240 mm
205 = 205 mm
225 = 225 mm
245 = 245 mm
TP 8080
Motor size
b
c**
d
f
h
m
n
p
u
v
w
x
y*
112M
641
535
136
335
403
124
278
190
27.5
112
250
85
71
25.5
132S / 132M
742
592/632
156
410
444
124
332
216
27.5
132
250
85
71
25.5
t*
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
54
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz
H
0
25
50
75
100
125
150
175
200
225
250
275
300
325
[ft] [m]
25
50
η 0.40
80
Ø250
75
100
125
150
175
20
200
225
η 0.55
η 0.60
η 0.60
η 0.64
Ø230
η 0.55
Ø220
60
η 0.50
η 0.66
Ø210
Ø200
15
50
250
IGPM
η 0.45 η 0.50
Ø240
70
Standard TP
40
10
30
20
5
50 Hz
10
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
Required NPSH-value
2.0
6.0
Ø250
1.5
4.0
Ø180
1.0
2.0
0.5
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
P
7.0
4.0
3.0
Ø230
4.0
Ø220
3.0
Ø210
Ø200
Ø190
Ø180
2.0
2.0
1.0
0
75
Ø250
Ø240
5.0
6.0
5.0
70
Q [m3/h]
[hp] [kW]
Required motor power
75
Q [m3/h]
NPSH
[ft] [m]
1.0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
55
50 Hz
4-pole
Ø190
Ø180
Standard TPS
Impeller diameter
25
0
USGPM
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 100 m³/h
Pump head
max. 12 m w.c.
Housing pressure
max. 16 bar
T P 1 6 0 4 0 2 5 0
1
4 3
4
5
D N N F K 1 5 0 1 0 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP16040
4
50
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 16040
4 = 4 pole
50 = 50 Hz
160 = 160 mm 165 = 165 mm
180 = 180 mm 185 = 185 mm
200 = 200 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
170 = 170 mm
190 = 190 mm
175 = 175 mm
195 = 195 mm
TP 16040
Motor size
b
c**
d
f
100L / 112M
651
538/545
131
335
403 108
278 160/190 29.5
112
280
85
86
27.5
132S / 132M
752
602/642
151
410
444 108
332
132
280
85
86
27.5
h
m
n
p
216
t*
29.5
u
v
w
x
y*
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
56
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz
H
0
100
50
150
200
250
300
350
450
400
[ft] [m]
0
50
100
150
η 0.50 η 0.55
Ø200
40
200
250
300
350
USGPM
IGPM
η 0.60
12
η 0.65
η 0.67
Ø190
11
35
η 0.65
10
Ø180
Impeller diameter
30
9
η 0.60
8
Ø170
η 0.55
25
7
Ø160
20
6
η 0.40
5
η 0.50
η 0.45
10
Standard TP
4
3
2
5
50 Hz
1
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Q [m3/h]
4.0
12
3.5
10
3.0
8.0
2.5
Ø200
2.0
6.0
1.5
4.0
Ø160
1.0
2.0
0.5
0
0
0
P
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
100 105
95
Q [m3/h]
[hp] [kW]
4.5
Required motor power
5.5
Ø200
5.0
3.5
4.5
3.0
4.0
Ø190
2.5
Ø180
3.0
2.5
2.0
1.5
2.0
Ø170
Ø160
1.5
1.0
1.0
0.5
0
0.5
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100 105
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
57
Standard TPS
Required NPSH-value
100 105
95
NPSH
[ft] [m]
50 Hz
4-pole
15
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 2-pole (n=3,500 min-1), 60 Hz
Standard version
2 pole/60Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 240 m3/h
Pump head
max. 130 m w.c.
TP 1020
30
20
40
30
TP 1540 bis TP8080
50
40
100
50
200
300
100
200
400
300
TP 16040
500
800
400
500
700
1200
1000
USGPM
IGPM
150
TP 2575-2
100
TP 5060-2
TP
TP2050-2
TP
70
60
-2
80
80
-2
TP 1540-2
Performance characteristics TP
50
TP 3050-2
TP 2030-2
40
TP 16040-2
30
H
[m]
20
TP 1020-2
10
5
1
n = 3,500 min-1
1
10
20
30
40
50
70
Q [m3/h]
58
100
200
300
GEA Tuchenhagen
Example of a standard selection
T P 0 1 0 2 0 2 6 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Standard version, for other versions see options
TP01020
2
60
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
012
5.
Code of selection characteristics
TP01020
2 = 2 pole
60 = 60 Hz
080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
Motor power 012 = 1.25 kW (IEC 80)
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
Selected values
determined by the
pump selected
Selection using the
characteristic curves
Performance curves, centrifugal pump,TP 1020 (2-polig / 60 Hz)
H
0
[ft] [m]
20
0
120
40
20
36
40
100
60
USGPM
80
IGPM
η 0.45
η 0.50
Ø120
100
Impeller diameter
80
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40
32
Impeller selection in
accordance with capacity
and pump head
60
28
80
Ø110
24
20
Ø100
16
Ø90
12
Ø80
60
40
8
20
60 Hz
4
Erforderlich NPSH
0
0
2
4
6
8
10
12
14
16
18
20
22
24
NPSH
[ft] [m]
12.5
4
10
3
7.5
26
Q [m3/h]
Ø80
Ø130
2
5
2.5
0
Motor output selection in
accordance with capacity
and pump head
0
1
0
2
0
4
6
8
10
12
14
16
18
20
22
24
3.6
3.2
2.8
2.8
Ø130
2.4
Ø120
2.0
Ø110
2.4
2.0
1.6
1.2
26
Q [m3/h]
P
[hp] [kW]
1.6
Ø100
1.2
Ø90
0.8
Ø80
0.8
0.4
0.4
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Q [m3/h]
59
60 Hz
2-pole
Designation
Standard TP
Pos
Standard TPS
Example
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 24 m³/h
Pump head
max. 34 m w.c.
Housing pressure
max. 10 bar
T P 0 1 0 2 0 2 6 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Example
Pos
Designation
Code of selection characteristics
TP01020
2
60
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
012
5.
Motor power
TP 1020
2 = 2 pole
60 = 60 Hz
080 = 80 mm
100 = 100 mm
090 = 90 mm
110 = 110 mm
012 = 1.25 kW (IEC 80)
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
TP 1020
Motor size
80
90S / 90L
100L / 112M
b
484
490
602
c**
d
390
144
425
144
474/496 154
f
285
285
335
h
352
352
403
m
76
76
76
n
228
228
278
p
125
140
160
120 = 120 mm
130 = 130 mm
t*
25.5
25.5
25.5
u
92
90
112
v
125
125
125
w
82
82
85
x
14
14
14
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
60
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 Hz
H
0
[ft] [m]
20
0
120
36
40
20
60
40
80
100
60
USGPM
80
IGPM
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40
η 0.45
32
η 0.50
Ø120
100
80
Ø110
24
20
Ø100
16
Ø90
12
Ø80
8
20
60 Hz
4
Required NPSH-value
0
0
0
2
4
6
8
10
12
14
16
18
20
22
24
NPSH
[ft] [m]
12.5
4
10
3
7.5
Ø80
Ø130
2
5
2.5
0
1
0
0
2
4
6
8
10
12
14
16
18
20
22
24
3.6
3.2
2.8
2.8
Ø130
2.4
Ø120
2.0
Ø110
2.4
2.0
1.6
1.2
26
Q [m3/h]
P
[hp] [kW]
Required motor power
26
Q [m3/h]
1.6
Ø100
1.2
Ø90
0.8
Ø80
0.8
0.4
0.4
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
61
60 Hz
2-pole
40
Standard TP
60
Standard TPS
Impeller diameter
28
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 44 m³/h
Pump head
max. 62 m w.c.
Housing pressure
max. 16 bar
T P 0 1 5 4 0 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01540
2
60
130
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 1540
2 = 2 pole
60 = 60 Hz
130 = 130 mm 140 = 140 mm
155 = 155 mm 160 = 160 mm
175 = 175 mm 180 = 180 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
TP 1540
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M (11 kW)
132M (15 kW)
b
608
608
608
709
709
c**
480
502
524
619
670
d
131.5
131.5
131.5
152
152
f
335
335
335
410
410
h
403
403
403
444
444
m
90
90
90
90
90
n
278
278
278
332
332
p
160
190
190
216
216
145 = 145 mm
165 = 165 mm
t*
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
150 = 150 mm
170 = 170 mm
v
140
140
140
140
140
w
85
85
85
85
85
x
42
42
42
42
42
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
62
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
200
225
[ft] [m]
0
70
25
Ø180
200
50
75
100
125
150
IGPM
η 0.30 η 0.35 η 0.40 η 0.45
η 0.50
η 0.55
60
η 0.57
Ø170
50
Ø160
150
Ø150
40
Ø140
20
50
60 Hz
10
Required NPSH-value
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
4
10
52
Q [m3/h]
NPSH
[ft] [m]
Ø130
Ø180
3
2
5
1
0
0
0
4
8
12
16
20
24
28
32
36
40
44
P
[hp] [kW]
48
52
Q [m3/h]
Required motor power
12
14
Ø180
10
Ø170
12
10
Ø160
8
Ø150
8
6
Ø140
Ø130
6
4
4
2
1
2
1
0
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
63
60 Hz
2-pole
Ø130
30
Standard TP
100
Standard TPS
Impeller diameter
175
USGPM
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 44 m³/h
Pump head
max. 52 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 3 0 2 6 0
1
2 3
4
5
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02030
2
60
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
015
5.
Motor power
TP 2030
2 = 2 pole
60 = 60 Hz
110 = 110 mm 120 = 120 mm
145 = 145 mm 150 = 150 mm
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
TP 2030
Motor size
90S / 90L
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M
b
494
606
606
606
707
c**
429
478
500
522
617
d
121.5
131.5
131.5
131.5
152
f
285
335
335
335
410
h
352
403
403
403
444
m
85
85
85
85
85
n
228
278
278
278
332
p
140
160
190
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
90
112
112
112
132
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
85
85
85
85
x
40
40
40
40
40
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
64
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
225
200
[ft] [m]
56
0
175
25
Ø160
48
Ø150
40
Ø140
50
η 0.30 η 0.35
75
100
η 0.40 η 0.45
125
150
175
USGPM
IGPM
η 0.50
η 0.60
125
Ø130
32
100
25
Required NPSH-value
0
Ø110
16
60 Hz
8
0
0
4
8
12
16
20
24
28
32
36
40
44
NPSH
[ft] [m]
48
52
Q [m3/h]
4
10
Ø110
3
Ø160
2
5
1
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
P
[hp] [kW]
Required motor power
10
12
10
8
Ø160
Ø150
8
6
6
Ø140
Ø130
4
2
0
Ø120
Ø110
4
2
0
0
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
65
60 Hz
2-pole
50
24
Standard TP
75
Ø120
Standard TPS
Impeller diameter
150
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 42 m³/h
Pump head
max. 85 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 5 0 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02050
2
60
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 2050
2 = 2 pole
60 = 60 Hz
160 = 160 mm 170 = 170 mm
190 = 190 mm 195 = 195 mm
210 = 210 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
TP 2050
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M (11 kW)
132M (15 kW)
b
622
622
622
723
723
c**
494
516
538
633
684
d
136
136
136
156
156
f
335
335
335
410
410
h
403
403
403
444
444
m
107
107
107
107
107
n
278
278
278
332
332
180 = 180 mm
200 = 200 mm
p
160
190
190
216
216
t*
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
185 = 185 mm
205 = 205 mm
v
161
161
161
161
161
w
85
85
85
85
85
x
52
52
52
52
52
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
66
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz
H
[ft] [m]
110
350
0
25
0
50
25
75
50
100
125
75
150
100
175
125
200
150
USGPM
IGPM
100
η 0.45
η 0.40
20
0
0
NPSH
[ft] [m]
10
60 Hz
0
5
10
15
20
25
3
7.5
30
35
40
Ø160
45
Q [m3/h]
Ø210
2
5
0
0
P
0
5
10
15
20
25
30
35
40
[kW]
45
Q [m3/h]
Ø210
15
Ø200
15
Ø190
10
Ø180
Ø170
10
5
0
Ø160
5
0
0
5
10
15
20
25
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
67
30
35
40
45
Q [m3/h]
Standard TPS
1
2.5
20
η 0.45
60 Hz
2-pole
Ø160
10
Required NPSH-value
η 0.50
30
50
Required motor power
η 0.52
40
[hp]
η 0.52
Ø170
50
100
η 0.50
Ø180
60
150
η 0.45
Ø190
70
200
η 0.40
Ø200
80
250
Impeller diameter
Ø210
90
Standard TP
300
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 48 m³/h
Pump head
max. 130 m w.c.
Housing pressure
max. 16 bar
T P 0 2 5 7 5 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02575
2
60
20
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
055
5.
Motor power
TP 2575
2 = 2 pole
60 = 60 Hz
200 = 200 mm 210 = 210 mm
225 = 225 mm 230 = 230 mm
245 = 245 mm 250 = 250 mm
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 2575
Motor size
112M (5.5 kW / 7.5 kW)
132M (11 kW)
132M (15 kW)
160L
200L
b
621
720
720
894
1,033
c**
515/537
630
681
782
908
d
138
156
156
191
200.5
f
335
410
410
640
810
h
m
n
403 124.5 278
444 107 332
444 107 332
598 124.5 412
668 124.5 472
p
190
216
216
254
318
215 = 215 mm
235 = 235 mm
t*
25.5
25.5
25.5
25.5
25.5
u
112
132
132
160
200
220 = 220 mm
240 = 240 mm
v
190
190
190
190
190
w
85
85
85
110
115
x
48.5
48.5
48.5
48.5
48.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
68
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
200
225
USGPM
[ft] [m]
0
450
120
100
125
η 0.35
η 0.40
150
175
IGPM
η 0.44
η 0.46
110
Ø230
100
η 0.46
Ø220
90
η 0.44
η 0.4
Ø210
80
8
Ø200
250
70
η 0.35
η 0.40
50
η 0.44
150
40
100
30
60 Hz
20
50
10
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
Required NPSH-value
NPSH
[ft] [m]
56
15
4.0
Ø250
Ø200
10
5
3.0
2.0
1.0
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
40
35
20
15
56
30
Ø250
25
Ø240
30
25
52
Q [m3/h]
P
[hp] [kW]
Required motor power
52
Q [m3/h]
20
Ø230
Ø220
15
Ø210
10
Ø200
10
5
0
5
0
0
4
8
12
16
20
24
28
32
36
40
44
48
52
56
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
69
60 Hz
2-pole
60
Standard TP
200
Standard TPS
Impeller diameter
75
Ø240
350
300
50
Ø250
130
400
25
140
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 85 m³/h
Pump head
max. 95 m w.c.
Housing pressure
max. 16 bar
T P 0 3 0 5 0 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP03050
2
60
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TP 3050
2 = 2 pole
60 = 60 Hz
140 = 140 mm 150 = 150 mm
175 = 175 mm 180 = 180 mm
195 = 195 mm 200 = 200 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
TP 3050
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M (11 kW)
132M (15 kW)
160L
b
618
618
618
719
719
893
c**
504
515
534
629
680
781
d
134
134
134
154
154
189
f
335
335
335
410
410
640
h
403
403
403
444
444
598
m
103
103
103
103
103
103
n
278
278
278
332
332
412
p
160
190
190
216
216
254
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
25.5
u
112
112
112
132
132
160
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
155
w
85
85
85
85
85
110
x
50
50
50
50
50
50
y*
25.5
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
70
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz
H
0
50
100
150
200
250
300
350
400
[ft] [m]
350
300
110
0
50
100
Ø210
90
Ø200
80
Ø190
70
Ø180
100
150
200
250
300
η 0.60
η 0.61
η 0.60
40
Ø140
30
η 0.45
20
50
0
η 0.40
60 Hz
10
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
NPSH
[ft] [m]
20
15
10
5
0
Q [m3/h]
6
5
4
3
Ø140
Ø210
2
1
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
30
Required motor power
35
Ø210
Ø200
25
30
25
20
15
Ø190
20
Ø180
15
Ø170
Ø160
10
Ø150
10
5
0
90
Q [m3/h]
P
[hp] [kW]
Ø140
5
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
71
60 Hz
2-pole
Ø150
150
Standard TP
50
Standard TPS
Impeller diameter
η 0.55
η 0.50
Ø170
60
Ø160
100
Required NPSH-value
IGPM
η 0.40 η 0.45 η 0.50 η 0.55
250
200
USGPM
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 80 m³/h
Pump head
max. 110 m w.c.
Housing pressure
max. 16 bar
T P 0 5 0 6 0 2 6 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP05060
2
60
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
055
5.
Motor power
TP 5060
2 = 2 pole
60 = 60 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
215 = 215 mm 220 = 220
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 5060
Motor size
112M (5.5 kW / 7.5 kW)
132M (11 kW)
132M (15 kW)
160L
200L
b
622
723
723
897
1,030
c**
517/538
633
684
785
905
d
137
157
157
192
195
f
335
410
410
640
810
h
403
444
444
598
673
m
114.5
114.5
114.5
114.5
114.5
n
278
332
332
412
472
mm
mm
mm
mm
p
190
216
216
254
318
165
185
205
225
=
=
=
=
t*
27.5
27.5
27.5
27.5
27.5
165
185
205
225
mm
mm
mm
mm
u
112
132
132
160
200
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
230
230
230
230
230
w
85
85
85
110
115
x
51
51
51
52
52
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
72
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz
0
50
100
150
200
250
300
350
400
USGPM
120
η 0.50
η 0.55
200
250
300
350
IGPM
η 0.58
Ø205
90
η 0.58
η 0.62
η 0.55
Ø195
250
η 0.50
Ø185
70
η 0.45
Ø175
60
η 0.40
Ø165
Ø155
50
150
Standard TP
Impeller diameter
150
Ø215
80
200
100
η 0.40 η 0.45
Ø225
110
100
300
50
40
100
30
20
50
60 Hz
10
0
0
Required NPSH-value
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
NPSH
[ft] [m]
20
15
10
5
0
95
100
Q [m3/h]
6
5
4
3
2
1
0
Ø225
Ø155
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Q [m3/h]
P
[hp] [kW]
40
50
Required motor power
45
40
35
Ø225
35
Ø215
30
Ø205
25
Ø195
30
25
20
15
20
Ø185
Ø175
15
Ø165
Ø155
10
10
5
5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
73
Standard TPS
350
0
60 Hz
2-pole
H
[ft] [m]
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 120 m³/h
Pump head
max. 105 m w.c.
Housing pressure
max. 16 bar
T P 0 7 0 6 0 2 6 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP07060
2
60
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
110
5.
Motor power
TP 7060
2 = 2 pole
60 = 60 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
220 = 220 mm 225 = 225
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
TP 7060
Motor size
112M
132M (11 kW)
132M (15 kW)
160L
200L
b
622
723
723
897
1,030
c**
538
633
684
785
905
d
132
152
152
187
190.5
f
335
410
410
640
810
h
427
444
444
596
668
m
110
110
110
110
110
n
278
332
332
412
472
mm
mm
mm
mm
p
190
216
216
254
318
165 = 165 mm
185 = 185 mm
205 = 205 mm
t*
27.5
27.5
27.5
27.5
27.5
u
112
132
132
160
200
170 = 170 mm
190 = 190 mm
215 = 215 mm
v
230
230
230
230
230
w
85
85
85
110
115
x
56
56
56
56
56
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
74
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz
H
[ft] [m]
120
η 0.66
η 0.55
η 0.50
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Ø155
7
140
150
140
150
Q [m3/h]
Ø225
6
5
15
4
3
10
2
5
1
0
P
0
10
20
30
40
50
60
70
80
90
100
110
120
130
[kW]
Q [m3/h]
60
Ø225
50
40
Ø215
Ø205
30
Ø195
20
Ø175
Ø165
Ø155
20
10
0
0
10
20
30
40
50
60
70
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
75
80
90
100
110
Ø185
120
130
140
150
Q [m3/h]
60 Hz
2-pole
60 Hz
8
20
0
η 0.60
Standard TPS
Impeller diameter
Required NPSH-value
η 0.65
Standard TP
0
0
Required motor power
η 0.60
Ø165
10
25
10
IGPM
Ø155
20
30
30
500
30
NPSH
[ft] [m]
40
USGPM
40
0
50
400
Ø175
50
50
60
600
Ø185
60
100
70
η 0.50 η 0.55
500
300
Ø195
70
150
400
200
Ø205
80
200
300
Ø215
90
250
200
100
Ø225
100
300
100
0
110
350
[hp]
0
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 125 m³/h
Pump head
max. 130 m w.c.
Housing pressure
max. 16 bar
T P 0 8 0 8 0 2 6 0
1
2 3
4
5
D N N F K 1 0 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP08080
2
60
180
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
150
5.
Motor power
TP 8080
2 = 2 pole
60 = 60 Hz
180 = 180 mm
210 = 210 mm
230 = 230 mm
250 = 250 mm
110 = 11.0 kW
150 = 15.0 kW
212 = 21.2 kW
220 = 22.0 kW
300 = 30.0 kW
370 = 37.0 kW
450 = 45.0 kW
TP 8080
Motor size
132M
160L
200L
225M
b
742
916
1,050
1,076
c**
652/703
804
925
961
d
156
191
195
195
f
410
640
810
810
h
444
598
668
720
190 = 190 mm
215 = 215 mm
235 = 235 mm
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
200 = 200 mm
220 = 220 mm
240 = 240 mm
205 = 205 mm
225 = 225 mm
245 = 245 mm
132M)
132M)
160L)
160L)
200L)
200L)
225M)
m
124
124
124
124
n
332
412
472
472
p
216
254
318
356
t*
27.5
27.5
27.5
27.5
u
132
160
200
200
v
250
250
250
250
w
85
110
115
115
x
71
71
71
71
y*
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
76
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz
0
100
200
300
400
500
600
USGPM
0
400
300
250
Ø250
130
Ø240
120
Ø230
110
Ø220
100
Ø210
90
Ø200
80
Ø190
150
η 0.55
η 0.64
η 0.55
η 0.66
Ø180
60
50
η 0.50
30
20
60 Hz
50
10
Required NPSH-value
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Q [m3/h]
NPSH
[ft] [m]
10
30
20
8
Ø180
Ø250
6
4
10
0
2
0
0
P
[hp] [kW]
70
Required motor power
IGPM
η 0.60
40
100
500
η 0.60
70
200
η 0.45 η 0.50
400
300
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Ø250
50
Ø240
Ø230
Ø210
40
Ø200
50
30
160
Ø220
60
40
150
Q [m3/h]
Ø190
30
Ø180
20
20
10
10
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
77
Standard TPS
Impeller diameter
350
η 0.40
200
Standard TP
450
140
100
60 Hz
2-pole
H
[ft] [m]
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 240 m³/h
Pump head
max. 70 m w.c.
Housing pressure
max. 16 bar
T P 1 6 0 4 0 2 6 0
1
2 3
4
5
D N N F K 1 5 0 1 0 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP16040
2
60
180
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
150
5.
Motor power
TP 16040
2 = 2 pole
60 = 60 Hz
160 = 160 mm
180 = 180 mm
200 = 200 mm
110 = 11.0 kW
150 = 15.0 kW
212 = 21.2 kW
220 = 22.0 kW
300 = 30.0 kW
370 = 37.0 kW
450 = 45.0 kW
TP 16040
Motor size
132M
160L
200L
225M
b
752
926
1,059
1,085
c**
713
814
934
970
d
151
186
189
189
f
410
640
810
810
h
444
596
668
720
165 = 165 mm
185 = 185 mm
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
(IEC
170 = 170 mm
190 = 190 mm
175 = 175 mm
195 = 195 mm
132M)
132M)
160L)
160L)
200L)
200L)
225M)
m
108
108
108
108
n
332
412
472
521
p
216
254
318
356
t*
29.5
29.5
29.5
29.5
u
132
160
200
225
v
280
280
280
280
w
85
110
115
115
x
86
86
86
86
y*
27.5
27.5
27.5
27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
78
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz
H
0
[ft] [m]
80
0
250
300
150
100
200
450
400
300
η 0.50
Ø200
600
η 0.55
750
500
η 0.60
70
600
η 0.65
Ø190
200
900
700
1050
800
1200
1000
900
USGPM
IGPM
η 0.67
η 0.65
60
η 0.60
50
Ø170
150
40
η 0.40
30
η 0.50
η 0.45
20
50
60 Hz
10
Required NPSH-value
0
0
0
20
40
60
80
100
120
140
160
180
200
220
NPSH
[ft] [m]
50
16
40
12
30
260
Q [m3/h]
Ø200
8
20
10
0
4
Ø160
0
0
20
40
60
80
100
120
140
160
180
200
220
80
60
70
50
240
260
Q [m3/h]
P
[hp] [kW]
Required motor power
240
Ø200
60
50
40
30
40
Ø190
Ø180
30
Ø170
20
Ø160
20
10
0
10
0
0
20
40
60
80
100
120
140
160
180
200
220
240
260
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
79
60 Hz
2-pole
Ø160
Standard TP
100
η 0.55
Standard TPS
Impeller diameter
Ø180
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 4-pole (n=1,750 min-1), 60 Hz
Standard version
4 pole/60Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 120 m3/h
Pump head
max. 34 m w.c.
TP 1020
30
Performance characteristics TP
40
20
TP 1540 bis TP8080
40
30
30
25
TP 2575-4
20
TP 2050-4
50
40
100
50
TP 16040
200
100
300
200
400
500 600
500
300
TP 8080-4
TP 5
0604
TP 1540-4
TP 7060
TP 3050-4
10
TP 16040-4
H
[m]
5
TP 1020-4
3
TP 2030-4
2
1
n = 1,750 min-1
1
10
20
30
Q [m3/h]
80
40
50
100
140
USGPM
IGPM
GEA Tuchenhagen
Example of a standard selection
T P 0 1 0 2 0 4 6 0
1
2 3
4
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Standard version, for other versions see options
Pos
Designation
TP01020
4
60
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
009
5.
Code of selection characteristics
TP01020
4 = 4 pole
60 = 60 Hz
080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
Selected values
determined by the
pump selected
Selection using the
characteristic curves
Performance curves, centrifugal pump, TP 1020 (4-polig / 60 Hz)
H
0
[ft] [m]
10
0
30
20
30
10
9
40
20
50
30
USGPM
40
IGPM
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40
Standard TP
Example
η 0.45
8
η 0.50
Ø120
25
Impeller selection in
accordance with capacity
and pump head
20
Ø110
6
5
Ø100
4
Ø90
3
Ø80
60 Hz
4-pole
Impeller diameter
7
15
10
60 Hz
1
Required NPSH-value
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
NPSH
[ft] [m]
6.0
2.0
5.0
1.5
Ø80
4.0
3.0
2.0
1.0
0
Ø130
1.0
0.5
0
1
0
2
3
4
5
6
7
8
9
10
11
12
Motor output selection in
accordance with capacity
and pump head
13
Q [m3/h]
P
[hp] [kW]
0.4
13
Q [m3/h]
Ø130
0.3
Ø120
0.3
Ø110
0.2
Ø100
0.2
Ø90
0.1
Ø80
0.1
0
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Q [m3/h]
81
Standard TPS
2
5
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max 11 m³/h
Pump head
max. 8 m w.c.
Housing pressure
max. 10 bar
T P 0 1 0 2 0 4 6 0
1
2 3
4
5
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01020
4
60
080
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 1020
4 = 4 pole
60 = 60 Hz
080 = 80 mm
100 = 100 mm
090 = 90 mm
110 = 110 mm
007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
120 = 120 mm
130 = 130 mm
TP 1020
Motor size
b
c**
d
f
h
m
n
p
t*
u
v
w
x
y*
80
484
390
144
285
352
76
228
125
25.5
92
125
82
14
25.5
90S / 90L
490
425
144
285
352
76
228
140
25.5
90
125
82
14
25.5
100L
602
474
154
335
403
76
278
160
25.5
112
125
85
14
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
82
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz
H
10
0
20
30
40
50
USGPM
[ft] [m]
0
30
9
10
20
30
40
IGPM
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40
η 0.45
8
η 0.50
Ø120
25
20
Ø110
6
5
Ø100
4
Ø90
3
Ø80
10
Standard TP
15
2
5
60 Hz
1
0
0
1
2
3
4
5
6
7
8
9
10
11
12
NPSH
[ft] [m]
6.0
2.0
5.0
1.5
Ø80
4.0
3.0
2.0
1.0
0
Ø130
1.0
0.5
0
0
1
2
3
4
5
6
7
8
9
10
11
12
Required motor power
13
Q [m3/h]
P
[hp] [kW]
0.4
13
Q [m3/h]
60 Hz
4-pole
Required NPSH-value
0
Ø130
0.3
Ø120
0.3
Ø110
0.2
Ø100
0.2
Ø90
0.1
Ø80
0.1
0
0
0
1
2
3
4
5
6
7
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
83
8
9
10
11
12
13
Q [m3/h]
Standard TPS
Impeller diameter
7
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 22 m³/h
Pump head
max. 15,5 m w.c.
Housing pressure
max. 16 bar
T P 0 1 5 4 0 4 6 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP01540
4
60
130
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 1540
4 = 4 pole
60 = 60 Hz
130 = 130 mm
155 = 155 mm
175 = 175 mm
007 = 0.75 kW
012 = 1.25 kW
018 = 1.8 kW
022 = 2.2 kW
140 = 140 mm
160 = 160 mm
180 = 180 mm
(IEC 80)
(IEC 90S)
(IEC 90L)
(IEC 100L)
145 = 145 mm
165 = 165 mm
150 = 150 mm
170 = 170 mm
TP 1540
Motor size
b
c**
80
490
396
90S / 90L
496
431
121.5
285
352
90
228
140
25.5
90
140
82
42
25.5
100L
608
480
131.5
335
403
90
278
160
25.5
112
140
85
42
25.5
d
121.5
f
h
m
n
p
t*
u
v
w
x
y*
285
352
90
228
125
25.5
92
140
82
42
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
84
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz
H
20
0
40
60
100
80
USGPM
[ft] [m]
0
20
Ø180
16
40
60
14
η 0.57
Ø170
Ø160
12
Ø150
10
Ø140
30
8
Standard TP
6
4
10
60 Hz
2
Required NPSH-value
0
0
0
2
4
6
8
10
12
14
16
18
20
22
24
Q [m3/h]
NPSH
[ft] [m]
12.5
4
10
3
7.5
Ø130
Ø180
2
5
2.5
0
1
0
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Q [m3/h]
P
[hp] [kW]
Required motor power
26
60 Hz
4-pole
20
Ø130
1.4
1.8
Ø180
1.6
1.2
1.4
1.0
Ø170
Ø160
1.2
1.0
Ø150
0.8
0.8
0.6
0.6
0.4
Ø140
Ø130
0.4
0.2
0.2
0
2
4
6
8
10
12
14
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
85
16
18
20
22
24
26
Q [m3/h]
Standard TPS
Impeller diameter
IGPM
η 0.55
50
40
80
η 0.30 η 0.35 η 0.40
η 0.45 η 0.50
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 23 m³/h
Pump head
max. 13 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 3 0 4 6 0
1
2 3
4
5
D N N F K 0 5 0 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02030
4
60
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 2030
4 = 4 pole
60 = 60 Hz
110 = 110 mm
145 = 145 mm
007 = 0.75 kW
012 = 1.25 kW
018 = 1.8 kW
022 = 2.2 kW
040 = 4.0 kW
055 = 5.5 kW
TP 2030
Motor size
80
90S / 90L
100L
112M
132S
b
488
494
606
606
707
c**
394
429
478
500
557
d
121.5
121.5
131.5
131.5
152
f
285
285
335
335
410
h
352
352
403
403
444
120 = 120 mm
150 = 150 mm
(IEC 80)
(IEC 90S)
(IEC 90L)
(IEC 100L)
(IEC 112M)
(IEC 132S)
m
85
85
85
85
85
n
228
228
278
278
332
p
125
140
160
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
92
90
112
112
132
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
82
85
85
85
x
40
40
40
40
40
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
86
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz
H
0
[ft] [m]
20
0
40
60
20
40
80
100
60
USGPM
80
IGPM
16
η 0.35
50
Ø160
12
Ø150
η 0.40 η 0.45
η 0.30
η 0.50
η 0.55
η 0.60
Ø140
10
30
Ø130
8
6
Ø110
4
10
60 Hz
2
Required NPSH-value
0
0
0
2
4
6
8
10
12
14
16
18
20
22
24
NPSH
[ft] [m]
12.5
4
10
3
7.5
Ø110
2
Ø160
5
2.5
0
1
0
0
2
4
6
8
10
12
14
16
18
20
22
24
1.8
1.6
1.4
1.4
1.2
1.0
Ø160
1.2
1.0
0.8
0.6
26
Q [m3/h]
P
[hp] [kW]
Required motor power
26
Q [m3/h]
60 Hz
4-pole
20
Standard TP
Ø120
Ø150
0.8
Ø140
Ø130
0.6
0.4
Ø120
Ø110
0.4
0.2
0.2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
87
Standard TPS
Impeller diameter
40
14
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 21 m³/h
Pump head
max. 22 m w.c.
Housing pressure
max. 16 bar
T P 0 2 0 5 0 4 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02050
4
60
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 2050
4 = 4 pole
60 = 60 Hz
160 = 160 mm
190 = 190 mm
210 = 210 mm
007 = 0.75 kW
012 = 1.25 kW
018 = 1.8 kW
022 = 2.2 kW
040 = 4.0 kW
TP 2050
Motor size
80
90S / 90L
100L
112M
b
504
510
622
622
c**
410
445
494
516
d
126
126
136
136
f
285
285
335
335
h
352
352
403
403
170 = 170 mm
195 = 195 mm
(IEC
(IEC
(IEC
(IEC
(IEC
180 = 180 mm
200 = 200 mm
185 = 185 mm
205 = 205 mm
80)
90S)
90L)
100L)
112M)
m
107
107
107
107
n
228
228
278
278
p
125
140
160
190
t*
25.5
25.5
25.5
25.5
u
90
90
112
112
v
161
161
161
161
w
82
82
85
85
x
52
52
52
52
y*
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
88
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz
H
[ft] [m]
100
28
80
24
0
40
30
12.5
25
Ø210
62.5
50
37.5
η 0.40
η 0.45
20
87.5
75
50
62.5
75
USGPM
87.5
IGPM
η 0.52
η 0.52
Ø190
η 0.50
η 0.45
Ø180
16
100
η 0.50
Ø200
60
50
37.5
25
Ø170
Ø160
12
η 0.40
Standard TP
Impeller diameter
70
12.5
0
η 0.45
8
20
Required motor power
0
NPSH
[ft] [m]
60 Hz
0
2
4
6
8
10
12
14
16
18
20
22
24
26
24
26
Q [m3/h]
2
5
2.5
0
0
0
P
[hp] [kW]
2.5
2
1.5
1
0.5
0
Ø210
Ø160
1
2
4
6
8
10
12
14
16
18
20
2
Q [m3/h]
Ø210
Ø200
1.5
Ø190
Ø180
Ø170
1
Ø160
0.5
0
22
0
2
4
6
8
10
12
14
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
89
16
18
20
22
24
26
Q [m3/h]
Standard TPS
Required NPSH-value
0
4
60 Hz
4-pole
10
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 22 m³/h
Pump head
max. 31 m w.c.
Housing pressure
max. 16 bar
T P 0 2 5 7 5 4 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP02575
4
60
200
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
040
5.
Motor power
TP 2575
4 = 4 pole
60 = 60 Hz
200 = 200 mm 210 = 210 mm
225 = 225 mm 230 = 230 mm
245 = 245 mm 250 = 250 mm
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 2575
Motor size
b
112M
621
515
138
335
132S / 132M
720
570/630
156
410
c**
d
f
h
m
n
215 = 215 mm
235 = 235 mm
220 = 220 mm
240 = 240 mm
p
t*
u
v
w
x
y*
403 124.5 278
190
25.5
112
190
85 48.5 25.5
444 124.5 332
216
25.5
132
190
85 48.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
90
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz
H
20
0
40
60
80
100
USGPM
[ft] [m]
0
20
40
Ø250
32
η 0.35
60
80
η 0.40
η 0.44
100
Ø240
28
η 0.46
η 0.46
Ø230
Ø220
24
η 0.44
Ø210
20
η 0.48
Ø200
60
16
40
η 0.35
Standard TP
Impeller diameter
80
IGPM
η 0.40
η 0.44
12
8
20
60 Hz
0
0
2
4
6
8
10
12
14
16
18
20
22
6
Ø250
Ø200
1
2
0.5
0
0
0
2
4
6
8
10
12
14
16
18
20
22
Required motor power
26
24
Q [m3/h]
P
[hp] [kW]
5.0
26
2
1.5
4
24
Q [m3/h]
NPSH
[ft] [m]
Ø250
3.5
4.5
4.0
3.0
3.5
2.5
Ø240
Ø230
3.0
2.5
2.0
2.0
1.5
1.5
1.0
Ø220
Ø210
Ø200
1.0
0.5
0.5
0
2
4
6
8
10
12
14
16
18
20
22
24
26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
91
Standard TPS
Required NPSH-value
0
60 Hz
4-pole
4
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 42 m³/h
Pump head
max. 24 m w.c.
Housing pressure
max. 16 bar
T P 0 3 0 5 0 4 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP03050
4
60
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
007
5.
Motor power
TP 3050
4 = 4 pole
60 = 60 Hz
140 = 140 mm
175 = 175 mm
195 = 195 mm
007 = 0.75 kW
012 = 1.25 kW
018 = 1.8 kW
022 = 2.2 kW
040 = 4.0 kW
055 = 5.5 kW
075 = 7.5 kW
TP 3050
Motor size
80
90S / 90L
100L
112M
132S / 132M
b
500
506
618
618
719
c**
406
441
490
512
569/609
d
124
124
134
134
154
f
285
285
335
335
410
h
352
352
403
403
444
150 = 150 mm
180 = 180 mm
200 = 200 mm
(IEC 80)
(IEC 90S)
(IEC 90L)
(IEC 100L)
(IEC 112M)
(IEC 132S)
(IEC 132M)
m
103
103
103
103
103
n
228
228
278
278
332
p
125
140
160
190
216
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
u
92
90
112
112
132
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
w
82
82
85
85
85
x
50
50
50
50
50
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
92
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
200
225
[ft] [m]
80
0
28
25
50
75
η 0.40 η 0.45
Ø210
24
100
125
η 0.61
Ø190
η 0.60
60
Ø180
16
η 0.55
Ø170
50
η 0.50
η 0.45
Ø160
40
IGPM
η 0.60
Ø200
Impeller diameter
175
η 0.55
70
20
150
η 0.40
Ø150
12
Standard TP
100
USGPM
Ø140
30
8
20
0
0
4
8
12
16
20
24
28
32
36
40
44
48
NPSH
[ft] [m]
4
10
Ø210
3
Ø140
2
5
1
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
5
4
52
Q [m3/h]
P
[hp] [kW]
Required motor power
52
Q [m3/h]
4
Ø210
Ø200
3
Ø190
3
Ø180
Ø170
Ø160
Ø150
2
2
1
0
1
Ø140
0
0
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
93
Standard TPS
Required NPSH-value
0
60 Hz
4-pole
60 Hz
4
10
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 45 m³/h
Pump head
max. 24 m w.c.
Housing pressure
max. 16 bar
T P 0 5 0 6 0 4 6 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP05060
4
60
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TP 5060
4 = 4 pole
60 = 60 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
215 = 215 mm 220 = 220
022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 5060
Motor size
100L
112M
132S / 132M
b
622
622
723
c**
d
494
137
516
137
573/613 157
f
335
335
410
h
m
n
403 114.5 278
403 114.5 278
444 114.5 332
mm
mm
mm
mm
p
160
190
216
165
185
205
225
=
=
=
=
t*
27.5
27.5
27.5
165
185
205
225
mm
mm
mm
mm
u
112
112
132
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
230
230
230
w
85
85
85
x
51
51
51
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
94
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
200
225
[ft] [m]
0
35
100
25
50
30
η 0.40
Ø225
η 0.45
100
125
150
175
η 0.50
η 0.55 η 0.58
η 0.58
Ø205
75
η 0.62
Ø195
20
η 0.55
η 0.50
Ø185
η 0.40
Ø175
50
IGPM
Ø215
25
15
η 0.45
Ø165
Standard TP
Ø155
10
25
60 Hz
5
0
0
4
8
12
16
20
24
28
32
36
40
44
48
Required NPSH-value
NPSH
[ft] [m]
2.5
7.5
Ø225
2.0
5
2.5
1.5
Ø155
1.0
0.5
0
0
0
4
8
12
16
20
24
28
32
36
40
44
48
5
Ø225
6
5
4
3
Ø215
4
Ø205
3
Ø195
Ø185
2
Ø175
Ø165
2
1
0
52
Q [m3/h]
P
[hp] [kW]
Required motor power
52
Q [m3/h]
60 Hz
4-pole
0
1
Ø155
0
0
4
8
12
16
20
24
28
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
95
32
36
40
44
48
52
Q [m3/h]
Standard TPS
Impeller diameter
75
USGPM
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 65 m³/h
Pump head
max. 27 m w.c.
Housing pressure
max. 16 bar
T P 0 7 0 6 0 4 6 0
1
2 3
4
5
D N N F K 0 8 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP07060
4
60
155
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TP 7060
4 = 4 pole
60 = 60 Hz
155 = 155 mm 160 = 160
175 = 175 mm 180 = 180
195 = 195 mm 200 = 200
220 = 220 mm 225 = 225
022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
TP 7060
Motor size
100L
112M
132S / 132M
b
622
622
723
c**
d
494
132
516
132
573/613 152
f
335
335
410
h
427
427
444
m
110
110
110
n
278
278
332
mm
mm
mm
mm
p
160
190
216
165 = 165 mm
185 = 185 mm
205 = 205 mm
t*
27.5
27.5
27.5
u
112
112
132
170 = 170 mm
190 = 190 mm
215 = 215 mm
v
230
230
230
w
85
85
85
x
56
56
56
y*
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
96
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz
[m]
30
0
20
0
Required NPSH-value
6.0
2.0
0
Required motor power
η 0.55 η 0.60
η 0.65
η 0.60
η 0.66
η 0.55
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
70
75
Q [m3/h]
Ø225
Ø155
0
5
10
15
20
25
30
35
40
45
50
55
60
65
Q
[m3/h]
7.0
5.0
0
IGPM
0.5
7.0
1.0
USGPM
1.0
6.0
2.0
250
1.5
8.0
3.0
225
325
60 Hz
P
[hp] [kW]
4.0
200
300
Ø165
5
2.5
5.0
175
275
10
8.0
6.0
250
Ø155
3.0
9.0
150
225
Ø175
15
3.5
10.0
125
200
η 0.50
10.0
0
175
Ø185
12.0
2.0
100
150
Ø195
20
NPSH
[ft] [m]
4.0
75
Ø205
10
0
η 0.50
125
Ø215
25
40
30
100
50
Ø225
60
50
75
60 Hz
4-pole
Impeller diameter
70
50
25
0
90
80
25
Standard TP
100
H
Ø225
Ø215
Ø205
4.0
Ø195
Ø185
3.0
2.0
Ø165
Ø155
1.0
0
0
5
10
15
20
25
30
35
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
97
40
45
50
Ø175
55
60
65
70
75
Q [m3/h]
Standard TPS
[ft]
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 75 m³/h
Pump head
max. 34 m w.c.
Housing pressure
max. 16 bar
T P 0 8 0 8 0 4 6 0
1
2 3
4
5
D N N F K 1 0 0 0 6 5 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP08080
4
60
180
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
040
5.
Motor power
TP 8080
4 = 4 pole
60 = 60 Hz
180 = 180 mm 190 = 190 mm
210 = 210 mm 215 = 215 mm
230 = 230 mm 235 = 235 mm
250 = 250 mm
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
200 = 200 mm
220 = 220 mm
240 = 240 mm
205 = 205 mm
225 = 225 mm
245 = 245 mm
TP 8080
Motor size
b
c**
d
f
h
m
n
p
u
v
w
x
y*
112M
641
535
136
335
403
124
278
190
27.5
112
250
85
71
25.5
132S / 132M
742
592/632
156
410
444
124
332
216
27.5
132
250
85
71
25.5
t*
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
98
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz
H
0
25
50
75
100
125
150
175
200
225
250
275
300
325
USGPM
[ft] [m]
25
0
32
125
150
175
200
225
250
275
IGPM
η 0.45 η 0.50
η 0.55
η 0.60
η 0.60
η 0.64
Ø220
24
Ø210
22
Ø200
20
Ø190
18
Ø180
η 0.55
η 0.66
Standard TP
26
16
14
40
12
10
η 0.50
8
20
6
2
Required NPSH-value
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
Q [m3/h]
NPSH
[ft] [m]
1.5
Ø180
2.0
6.0
Ø250
1.5
4.0
1.0
2.0
0.5
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
P
14
75
Q
[hp] [kW]
Required motor power
60 Hz
4-pole
60 Hz
4
10
80
[m3/h]
Ø250
12
8.0
Ø240
10
8.0
6.0
Ø230
6.0
Ø220
Ø210
4.0
4.0
2.0
0
Ø180
2.0
0
0
5
10
15
20
25
30
35
40
45
50
55
Ø200
Ø190
60
65
70
75
80
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
99
Standard TPS
Impeller diameter
100
Ø230
28
60
75
Ø240
30
80
η 0.40
Ø250
34
90
50
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 120 m³/h
Pump head
max. 17 m w.c.
Housing pressure
max. 16 bar
T P 1 6 0 4 0 4 6 0
1
2 3
4
5
D N N F K 1 5 0 1 0 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TP16040
4
60
160
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
040
5.
Motor power
TP 16040
4 = 4 pole
60 = 60 Hz
160 = 160 mm 165 = 165 mm
180 = 180 mm 185 = 185 mm
200 = 200 mm
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)
170 = 170 mm
190 = 190 mm
175 = 175 mm
195 = 195 mm
TP 16040
Motor size
b
112M
651
545
131
335
403 108
278
190
29.5
112
280
85
86
27.5
132S / 132M
752
602/642
151
410
444 108
332
216
29.5
132
280
85
86
27.5
c**
d
f
h
m
n
p
t*
u
v
w
x
y*
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
100
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz
H
0
[ft] [m]
0
60
75
175
50
100
150
Ø200
18
250
325
200
η 0.50
η 0.55
400
250
300
450
350
600
525
400
450
500
USGPM
IGPM
η 0.60
η 0.65
η 0.67
Ø190
16
50
η 0.65
Ø180
η 0.60
40
12
Ø170
η 0.55
10
Ø160
30
η 0.50
8
η 0.45
6
Standard TP
20
η 0.40
4
10
60 Hz
2
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
15
5
12.5
4
10
3
7.5
5
Ø200
2
Ø160
2.5
1
0
0
0
10
20
30
40
50
60
70
80
90
100
110
120
8
6
7
5
130
Q [m3/h]
P
[hp] [kW]
Required motor power
130
Q [m3/h]
60 Hz
4-pole
Required NPSH-value
NPSH
[ft] [m]
Ø200
Ø190
6
5
4
3
4
Ø180
Ø170
Ø160
3
2
2
1
1
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
101
Standard TPS
Impeller diameter
14
GEA Tuchenhagen
Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS
2-pole (n = 2,900 min-1)
H
[ft] [m]
250
0
50
0
100
50
150
100
200
250
150
200
70
200
300
350
250
USGPM
300
IGPM
50 Hz
60
50
150
40
100
TPS 3050
30
20
TPS 2030
50
10
0
0
0
5
10
15
20
25
30
35
102
40
45
50
55
60
65
70
75
80
85
Q [m3/h]
GEA Tuchenhagen
Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS
2-pole (n = 3,500 min-1)
H
[ft] [m]
350
110
0
50
0
100
50
150
200
100
250
150
300
200
250
250
400
300
USGPM
IGPM
60 Hz
100
300
350
90
80
70
200
150
TPS 3050
60
50
40
50
30
TPS 2030
20
10
0
0
0
5
10
15
20
25
30
35
40
103
45
50
55
60
65
70
75
80
85
90
Q [m3/h]
Standard TPS
100
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS, 2-pole (n=2,900 min-1), 50 Hz
Standard version
2 pole/50Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 55 m3/h
Pump head
max. 64 m w.c.
TPS 2030 und TPS 3050
2-pole (n=2,900 min-1), 50 Hz
Performance characteristics TPS
H
[ft] [m]
250
0
50
0
100
50
150
100
200
150
300
200
70
200
250
350
250
USGPM
300
IGPM
50 Hz
60
50
150
40
100
TPS 3050
30
20
TPS 2030
50
10
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
104
65
70
75
80
85
Q [m3/h]
GEA Tuchenhagen
Example of a standard selection
T P S 2 0 3 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Standard version, for other versions see options
Example
Pos
Designation
TPS 2030
2
50
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Code of selection characteristics
TPS 2030
2 = 2 pole
50 = 50 Hz
110 = 110 mm 120 = 120 mm 130 = 130 mm
140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm
Motor power 022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
Selected values
determined by the
pump selected
Selection using the
characteristic curves
Performance curves, centrifugal pump, TPS 2030 (2-polig / 50 Hz)
H
0
20
40
60
80
100
120
140
160
USGPM
[ft] [m]
44
0
20
40
60
80
100
140
120
IGPM
140
40
Ø160
η 0.20 η 0.25
36
η 0.30
32
Ø150
28
Ø140
24
Ø130
20
Ø120
16
Ø110
η 0.35
100
η 0.37
η 0.37
80
η 0.35
60
η 0.30
η 0.25
40
12
50 Hz
4
Required NPSH-value
0
0
0
5
NPSH
[ft] [m]
40
10
15
20
25
30
20
10
0
Q [m3/h]
12
10
30
40
35
Ø160
8
Ø110
6
4
2
0
0
P
[hp] [kW]
5
10
15
20
25
30
35
40
Q [m3/h]
5.5
Motor output selection in
accordance with capacity
and pump head
7.0
5.0
6.0
4.5
Ø160
Ø150
4.0
5.0
4.0
Ø140
3.5
Ø130
3.0
2.5
3.0
2.0
Ø120
Ø110
2.0
1.5
1.0
1.0
0
5
105
10
15
20
25
30
35
40
Q [m3/h]
Standard TPS
η 0.20
8
20
50 Hz
2-pole
Impeller selection in
accordance with capacity
and pump head
Impeller diameter
120
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 32 m³/h
Pump head
max. 37 m w.c.
Housing pressure
max. 16 bar
T P S 2 0 3 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TPS2030
2
50
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TPS 2030
2 = 2 pole
50 = 50 Hz
110 = 110 mm 120 = 120 mm
145 = 145 mm 150 = 150 mm
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.2 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
TP 2030
Motor size
90L
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M
b
594
706
706
706
808
c**
529
578
600
622
717.5
d
121.5
131.5
131.5
131.5
152
f
285
335
335
335
410
h
352
403
403
403
444
m
85
85
85
85
85
n
227
227
227
227
332
p
140
160
190
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
80
90
102
102
122
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
85
85
85
85
x
140.5
140.5
140.5
140.5
140.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
106
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz
44
140
20
0
40
20
Ø 160
80
60
40
60
80
40
100
60
120
80
100
32
Ø 150
28
Ø 140
24
Ø 130
20
Ø 120
16
Ø 110
NPSH
[ft] [m]
140
η 0.35
η 0,37
η 0.35
η 0.30
η 0.25
0
50 Hz
5
η 0.20
10
15
20
25
30
35
10
30
Ø 160
8
20
Ø 110
4
2
0
0
P
0
5
10
15
20
25
30
35
[hp] [kW]
Required motor power
5.0
4.0
3.0
2.0
1.0
5.5
40
Q [m 3/h ]
Ø 160
5.0
4.5
Ø 150
4.0
3.5
Ø 140
3.0
Ø 120
2.5
Ø 130
Ø 110
2.0
1.5
1.0
0
5
10
15
20
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
107
25
30
35
40
Q [m 3/h ]
50 Hz
2-pole
6
10
6.0
40
Q [m 3/h ]
12
40
7.0
IGPM
η 0.37
4
0
USGPM
η 0.30
8
0
160
120
12
20
140
η 0.20 η 0.25
36
100
Impeller diameter
0
40
120
Required NPSH-value
[m]
Standard TPS
[ft]
H
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 55 m³/h
Pump head
max. 64 m w.c.
Housing pressure
max. 16 bar
T P S 3 0 5 0 2 5 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TPS3050
2
50
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TPS 3050
2 = 2 pole
50 = 50 Hz
140 = 140 mm 150 = 150 mm
175 = 175 mm 180 = 180 mm
195 = 195 mm 200 = 200 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.2 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
TP 3050
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132 M
160 L
b
729
729
729
830
999
c**
600.5
622.5
644.5
740
886.5
d
133
133
133
153
183
f
335
335
335
410
640
h
403
403
403
444
598
m
103
103
103
103
103
n
227
227
227
332
408
p
160
190
190
216
254
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
u
90
102
102
122
150
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
w
85
85
85
85
110
x
161.5
161.5
161.5
161.5
161.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
108
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz
H
[ft] [m]
250
0
0
70
η 0.40
Ø140
η 0.35
50 Hz
0
5
10
15
20
η 0.30
η 0.25
25
30
35
40
45
50
55
60
65
70
75
60
65
70
75
60
65
70
75
80
85
80
85
80
85
Q [m3/h]
Ø210
Ø140
4
10
2
0
P
0
5
10
15
20
25
30
35
40
45
50
55
[kW]
Q [m3/h]
20
15
Ø 210
Ø 200
Ø 190
Ø 180
10
Ø 170
Ø 160
10
5
0
Ø 150
Ø 140
0
5
10
15
20
25
30
35
40
45
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
109
50
55
Q [m3/h]
50 Hz
2-pole
Required NPSH-value
η 0.44
6
20
0
IGPM
η 0.42
8
0
Required motor power
η 0.42
10
30
5
300
12
40
15
η 0.40
Ø150
30
10
20
250
USGPM
η 0.35
Ø160
50
25
200
350
Ø170
20
[hp]
300
Ø180
40
NPSH
[ft] [m]
η 0.30
250
150
Ø190
150
0
η 0.25
200
100
Ø200
50
0
150
50
Ø210
60
100
100
Standard TPS
Impeller diameter
200
50
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS, 2-pole (n=3,500 min-1), 60 Hz
Standard version
2 pole/60Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections
Depending on pump size
Mechanical seal
Single-acting, material: C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Standard equipment
Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 69 m3/h
Pump head
max. 95 m w.c.
TPS 2030 und TPS 3050
2-pole (n=3,500 min-1), 60 Hz
H
Performance characteristics TPS
[ft] [m]
350
110
0
50
0
100
50
150
100
200
250
150
200
100
300
250
300
350
250
400
300
IGPM
60 Hz
90
80
70
200
150
TPS 3050
60
50
40
100
50
30
TPS 2030
20
10
0
0
0
5
10
15
20
25
30
35
40
45
50
55
60
110
65
70
75
80
USGPM
85
90
Q [m3/h]
GEA Tuchenhagen
Example of a standard selection
T P S 2 0 3 0 2 6 0
1
2 3
4
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
5
Standard version, for other versions see options
Example
Pos
Designation
TPS2030
2
60
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Code of selection characteristics
TPS 2030
2 = 2 pole
60 = 60 Hz
110 = 110 mm 120 = 120 mm 130 = 130 mm
140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm
Motor power 022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
Selected values
determined by the
pump selected
Selection using the
characteristic curves
Performance curves, centrifugal pump, TPS 2030 (2-polig / 60 Hz)
H
0
25
50
75
100
125
150
175
200
225
[ft] [m]
56
0
25
Ø160
175
50
η 0.20 η 0.25
75
Impeller diameter
Impeller selection in
accordance with capacity
and pump head
100
125
150
175
USGPM
IGPM
η 0.30
η 0.35
48
Ø150
150
η 0.37
40
Ø140
32
Ø130
125
η 0.37
100
η 0.35
Ø120
75
50
24
η 0.30
Ø110
η 0.25
16
Required NPSH-value
0
60 Hz
8
0
0
4
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
10
30
Ø160
8
20
Ø110
6
4
10
2
0
0
0
Motor output selection in
accordance with capacity
and pump head
8
NPSH
[ft] [m]
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
P
[hp] [kW]
10
Ø160
12
10
8
6
8
Ø150
Ø140
6
Ø130
Ø120
4
Ø110
4
2
0
2
0
0
4
8
12
16
20
24
28
32
36
40
44
48
52
Q [m3/h]
111
60 Hz
2-pole
25
Standard TPS
η 0.20
Required motor power
Code
Position
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 36 m³/h
Pump head
max. 52 m w.c.
Housing pressure
max. 16 bar
T P S 2 0 3 0 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 4 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TPS2030
2
60
110
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
022
5.
Motor power
TPS 2030
2 = 2 pole
60 = 60 Hz
110 = 110 mm 120 = 120 mm
145 = 145 mm 150 = 150 mm
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
TP 2030
Motor size
90L
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132M
b
594
706
706
706
808
c**
529
578
600
622
717.5
d
121.5
131.5
131.5
131.5
152
f
285
335
335
335
410
h
352
403
403
403
444
m
85
85
85
85
85
n
227
227
227
227
332
p
140
160
190
190
216
130 = 130 mm
155 = 155 mm
t*
25.5
25.5
25.5
25.5
25.5
u
80
90
102
102
122
140 = 140 mm
160 = 160 mm
v
135
135
135
135
135
w
82
85
85
85
85
x
140.5
140.5
140.5
140.5
140.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
112
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz
H
[ft] [m]
56
0
0
50
η 0.20 η 0.25
125
75
150
100
175
125
200
150
225
175
USGPM
IGPM
η 0.30
η 0.35
48
Ø150
40
Ø140
32
Ø130
η 0.37
75
0
24
20
10
0
η 0.25
0
10
8
6
4
2
0
η 0.20
60 Hz
8
0
4
8
12
16
20
24
28
32
36
40
44
48
52
44
48
52
44
48
52
Q [m3/h]
10
Ø160
8
Ø110
6
4
2
0
0
P
[hp] [kW]
12
η 0.30
Ø110
16
NPSH
[ft] [m]
30
η 0.35
Ø120
4
8
12
16
20
24
28
32
36
40
Q [m3/h]
10
Ø160
8
Ø150
Ø140
6
Ø130
Ø120
4
Ø110
2
0
0
4
8
12
16
20
24
28
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
113
32
36
40
Q [m3/h]
60 Hz
2-pole
100
25
Required NPSH-value
100
η 0.37
50
Required motor power
75
Standard TPS
Impeller diameter
125
50
25
Ø160
175
150
25
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz
Materials
Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections
DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal
Single-acting, material C / SIC / EPDM
Static seals
EPDM (FDA, USP Class VI)
Equipment
Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor
Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Code
Position
Documentation
Operating instructions, declaration of conformity
Flow rate
max. 69 m³/h
Pump head
max. 95 m w.c.
Housing pressure
max. 16 bar
T P S 3 0 5 0 2 6 0
1
2 3
4
5
D N N F K 0 6 5 0 5 0 E K E - 1 - J J 6
7
8
9
10 11 12 13 14 15 16 17
Example
Pos
Designation
Code of selection characteristics
TPS3050
2
60
140
1.
2.
3.
4.
Type
Speed
Frequency
Impeller
030
5.
Motor power
TPS 3050
2 = 2 pole
60 = 60 Hz
140 = 140 mm 150 = 150 mm
175 = 175 mm 180 = 180 mm
195 = 195 mm 200 = 200 mm
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
TP 3050
Motor size
100L
112M (4 kW + 5.5 kW)
112M (7.5 kW)
132 M
160 L
b
729
729
729
830
999
c**
600.5
622.5
644.5
740
886.5
d
133
133
133
153
183
f
335
335
335
410
640
h
403
403
403
444
598
m
103
103
103
103
103
n
227
227
227
332
408
p
160
190
190
216
254
160 = 160 mm
185 = 185 mm
205 = 205 mm
t*
25.5
25.5
25.5
25.5
25.5
u
90
102
102
122
150
170 = 170 mm
190 = 190 mm
210 = 210 mm
v
155
155
155
155
155
w
85
85
85
85
110
x
161.5
161.5
161.5
161.5
161.5
y*
25.5
25.5
25.5
25.5
25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors
All dimensions in mm
114
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz
110
350
0
0
100
300
Impeller diameter
70
Ø180
60
Ø170
Required NPSH-value
Required motor power
0
NPSH
[ft] [m]
20
4
2
0
10
0
20
15
10
5
0
η 0.35
200
P
400
350
250
300
IGPM
η 0.42
η 0.44
η 0.42
η 0.40
η 0.35
0
60 Hz
5
10
15
20
η 0.30
η 0.25
25
30
35
40
45
50
55
60
5
10
15
20
25
30
35
40
45
70
75
80
85
70
75
80
85
70
75
80
85
90
Q [m3/h]
Ø210
Ø140
0
65
50
55
60
65
[kW]
90
Q [m3/h]
30
25
Ø 210
Ø 200
20
Ø 190
15
Ø 180
Ø 170
Ø 160
Ø 150
10
Ø 140
5
0
USGPM
η 0.40
10
8
6
30
25
η 0.30
12
40
300
Ø140
20
0
30
150
Ø150
10
35
250
30
50
[hp]
200
Ø160
40
100
100
Ø190
50
150
150
η 0.25
Ø200
80
200
100
50
Ø210
90
250
50
0
5
10
15
20
25
30
35
40
45
50
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%
115
55
60
65
90
Q [m3/h]
60 Hz
2-pole
[ft] [m]
Standard TPS
H
GEA Tuchenhagen
Options for TP and TPS series
Standard
Options
Position
Example
D N N F K - - 1
2
3
4
5
6
7
Pos
Designation
Code of selection characteristics
6.
Nominal width
standard
DN = DIN 11850
OD = Zoll OD
- E K E - 1 - J J 9
DN
40, 50,
65, 80
GSK
7.
8.
9.
Connection type
*1)
Connection sizes
suction side (SS)
Connection sizes
Pressure side (DS)
NFK = Hygienic grooved flange
DIN 11853-2 (standard)
ASK = Hygienic flange connection
DIN 11853-2, cpl.
GO = Male part
DIN 11851
GK = Pipe connection
DIN 11851, cpl.
TN = VARIVENT® grooved flange
TK = VARIVENT® flange connection
GSK = Hygienic male part
DIN 11853-1
AVK = Hygienic union
DIN 11853-1, cpl.
CO = Tri-Clamp analogous to
DIN 32676 / ISO 2852
SMG = SMS male part
SMK = SMS connection cpl.
040 = DN 40
050 = DN 50
112 = 1.5" OD
200 = 2" OD
065 = DN 65
212 = 2.5" OD
080 = DN 80
300 = 3" OD
100
125
150
040
400 = 4" OD
=
=
=
=
DN
DN
DN
DN
100
125
150
40
112 = 1.5" OD
050 = DN 50
200 = 2" OD
065 = DN 65
080 = DN 80
100 = DN 100
212 = 2.5" OD
300 = 3" OD
400 = 4" OD
*1) For TP 16040 on request
*2) Versions available on request
116
TP 1020
TP 1020
TP 2030
TP 1540
TP 2030
TP 2050
TP 1540
TP 2050
TP 2575
TP 8080
TP 16040
TP 16040
TP 1020
TP 1540
TP 1020
TP 1540
TP 2030
TP 5060
TP 5060
TP 16040
10 11 12 13 14 15 16 17
DN
100
DN
125, 150
OD
1.5“, 2“
2.5“, 3“
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
*2)
DN not available
DN not available
DN not available
TP 2050
TP 3050
TP 2575
TP 3050
TP 5060
TP 3050
TP 5060
TP 7060
TP 16040
TP 2030
TPS 2030
TP 2050
TP 2575
TP 3050
TP 7060
TP 7060
OD
4“
TP 7060
TPS 2030
TPS 3050
TP 8080
TPS 2030
TPS 3050
TP 8080
TP 8080
GEA Tuchenhagen
Options for TP and TPS series
Standard
Options
Position
Example
PS
D N N F K - - 1
Pos
10.
2
3
Designation
Design /
Material of
mechanical seal
4
5
6
7
8
- E K E - 1 - J J 9
10 11 12 13 14 15 16 17
Code of selection characteristics
TP 1020
TP 2575
TPS 2030
TP 1540
TP 5060
TPS 3050
TP 2030
TP 7060
TP 2050
TP 8080
TP 3050
TP 16040
Single-acting
EK = carbon / silicon carbide (standard)
EH = carbon / chrome molybdenum
ES = silicon carbide / silicon carbide
Single acting with flush
QK = with flush - carbon / silicon carbide
QH = with flush - carbon / chrome molybdenum
QS = with flush - silicon carbide / silicon carbide
Standard TP
Double-acting
PS = with flush - silicon carbide / silicon carbide
F
11.
Static seals
D
12.
Drainage
E = EPDM (Standard)
F = FKM
- = no drainage valve (standard)
D = drainage valve type VTP *3)
C = with drainage connection Tri-Clamp DN 15 *3)
(analogous to 32676 / ISO 2852)
3
13.
Product contact
Surfaces
X
14.
Explosion protection
class*4)
1 = Ra ≤ 3.2µm (Standard)
3 = Ra ≤ 0.8µm electro-polished
Motor power
0.75 kW 1.1 kW
1.5 kW
2.2 kW
3.0 kW
4.0 kW
5.5 kW
- = without (standard)
X = with ATEX
(II2G Eex d IIB T4)
Motor power
7.5 kW 11.0 kW 15.0 kW 18.5 kW 22.0 kW 30.0 kW 37.0 kW 45.0 kW
- = without (standard)
(II2G Eex d IIB T4)
J
15.
Stainless steel
protection
Motor size
J=
80
90S/90L
100L
160L
200L
225M
80
90S/90L
100L
160L
200L
225M
112M
132S/132M
112M
132S/132M
with (standard)
N = without
Motor size
J=
with (standard)
Standard TPS
X = mit ATEX
N = without
J
16.
Calotte-type frame
Motor size
J=
with (standard)
Motor size
J=
with (standard)
N = without
Z
17.
Certificates
-=
without (standard)
O = surface measurement report
Z=
acceptance test certificate 3.1 DIN/EN 10204
*3) 2 pieces for TPS Pumps
*4) 30 kW ATEX on request
117
Options
N = without
GEA Tuchenhagen
Options for TP and TPS series
Mechanical seal design options
Single-acting (standard) mechanical seal
Single-acting, flushed (Quench)
mechanical seal
Double-acting mechanical seal
Slide ring holder,
Second slide ring
Shaft sealing ring
and counter ring on both sides
and shaft protection sleeve
Crystallizing and
Hazardous,
highly viscous products (≥100 cP)
abrasive and dilatant fluids
Two sizes for the entire TP(S) program, easy to replace
Encapsulated spring, seal ring, counter ring, dead-space free
Drainage
Drainage valve type VTP
Drainage connector Tri-Clamp 1/2“, DN 15
For complete draining of the pump
housing without any dead corners.
Safe closing function, even in the event
of pressure surges in the system.
Variable connection for individual
draining
Advantages of hygienic flange connection compared with dairy union
⊕Gap-free seal
 No gap-free seal
⊕Defined deformation of seal
 Undefined deformation of seal
⊕Metallic stop
 No metallic stop
Hygienic flange connection (DIN 11853-2)
Dairy union (DIN 11851-1)
118
GEA Tuchenhagen
Special versions for TP and TPS series on request
VESTA® valves for draining
Carriage for pump
Standard TP
Inducer for TP series
Heating jacket for TP series
Also available on request:
Options
Standard TPS
• Other connection types
• Noise protection hood
• Other motor designs and manufacturers
119
GEA Tuchenhagen
Sealing sets and mechanical seals
TP Series
O-ring*
O-ring*
Mechanical seal
O-ring*
TPS Series
* included in sealing sets
Sealing sets
Pump type
EPDM sealing set
FKM sealing set
TP 1020
TP 1540
TP 2030
TP 2050
TP 3050
TP 5060
TP 7060
TP 2575
TP 8080
TP 16040
TPS 2030
TPS 3050
Part number
244-000125
244-000126
244-000127
244-001024
244-000221
244-000458
244-001054
244-000467
244-000336
244-000519
244-000696
244-000785
Part number
244-000128
244-000129
244-000130
244-001032
244-000222
244-000466
244-001055
244-000468
244-000384
244-000520
244-000697
244-000786
Mechanical seals
Mechanical seal
Configuration
Type
EW/QU*
EW/QU*
EW/QU*
EW/QU*
EW/QU*
EW/QU*
DW
DW
Shaft seal
Pump type
TP 1020; TP(S) 2030; TP 1540;
TP 2050; TP(S) 3050
Material
C/SIC/EPDM
C/CrMo/EPDM
SIC/SIC/EPDM
C/SIC/FKM
C/CrMo/FKM
SIC/SIC/FKM
SIC/SIC/EPDM
SIC/SIC/FKM
Part number
244-000045
244-000531
244-000043
244-000044
244-000532
244-000042
244-000135
244-000136
100-000014
* For mechanical seal QU is recommended to change the shaft seal in addition
120
TP 5060; TP 7060; TP 2575;
TP 8080; TP 16040
Part number
244-000345
244-000533
244-000382
244-000381
244-000534
244-000383
244-000378
244-000379
924-342
GEA Mechanical Equipment
GEA Tuchenhagen GmbH
Pumps
Checklist
Am Industriepark 2-10, 21514 Büchen
Phon +49-4155 49-0, Fax +49-4155 49-2428
sales.geatuchenhagen@gea.com
www.tuchenhagen.com
1 Company / Cust. No:
Contact:
Phone:
Fax:
E-Mail:
3 Flow parameters*
4 Operating frequency
£ 50 Hz
Pressure:
£ 60 Hz
bar
(if not given "50Hz" assumed)
6 Application*
(if unknown no. 9 essential!)
Viscosity:
Density:
(if not given "1 cP" assumed)
(if not given "1 kg/dm3" assumed)
£ nonself-priming (TP Series)
Execution:
Material:
8 Static seals
(if unknown no. 9 essential!)
9 Fluid
10 Connections
(suction and pressure nozzles)
11 Version
Material:
£ self-priming (TPS Series)
£ single acting (Standard) £ single flushed (Quench)
£ double flushed
£ C / SIC (Standard)
£ SIC / SIC (double floushes only in SIC / SIC!)
£ EPDM (Standard)
£ FKM (Viton®)
Medium:
Temperature:
Viscosity:
£ Hygienic grooved flange DIN 11853-2 (standard) £ DIN 11853-2 (Hygienic flange)
£ SMS
£ other:
£ with stainless steel cover
£ with adjustable calotte feet
£ VARIVENT® flange
Standard TP
5 Fluid
7 Mechanical seals
£ complete, incl. counterpiece
£ stainless steel cover with acoustic insulation
or
£ carrier without electrical connection
£ carrier with electrical connection
(incl. safety switch and 10 m cable and plug)
12 Actuator / Motor
Manufacturer:
£
Protection class: R
ATEX:
£
Adjustment control: R
13 Options
£ 3~ 400V/50Hz (Europe)
existing supply voltage
Surface:
(Product contacted)
Drain:
Heating:
Certificates:
£ 3~ 200V/60Hz (e.g. Japan)
£ 3~ 380V/60Hz (e.g. Brazil)
GEA Tuchenhagen Standard
£ other:
or
£ ABB
or
£ II G Eex de IIB T4
IP 55 (Standard)
II G Eex d IIB T4
£ 3~ 460V/60Hz
£ 3~ 200V/50Hz (e.g. Japan)
Thermistor (PTC) (Standard)
£ matt blank (Standard)
£ Drainvalve VTP
£ Heating- or cooling jackets
£ 3.1 Certificate DIN/EN 10204
£ Surface measurement report
£ Ra ≤ 0.8 µm
or
£ Drainpipe
DN 15 with TriClamp
£ Performance test certificate
14 Marks / Other
* Please fill out all required fields
The checklist can also be found on www.tuchenhagen.com
121
GEA Tuchenhagen
Spare Parts
Gasket selection
(m3/h)
Flow rate:
Standard TPS
Pump performance
2 Project / Tag No:
General Sales Terms and Conditions
of GEA Tuchenhagen GmbH
(Edition May 2003)
Any contract placed with us (hereinafter referred to as “the
Seller”) by any private-law corporation, company or other
business or any public-law legal person or other entity
(hereinafter referred to as “the Buyer”) shall exclusively be
subject to these Standard Sales Terms and these Standard Sales
Terms shall be applicable to any transaction agreed between the
Seller and the Buyer thereafter even if no express reference to
these Standard Sales Terms is made in connection with any
such further transaction. The Seller hereby expressly refuses to
accept any standard terms of the Buyer referred to in any
correspondence or other document placing any such order.
Notwithstanding any reference of the Buyer to any standard
terms of the Buyer, the Buyer shall, upon the acceptance of any
delivery by the Seller to the Buyer, be deemed to have accepted
these Standard Sales Terms. No standard terms of the Buyer
shall be applicable to any contract or order placed by the Buyer
with the Seller unless such terms have been accepted expressly
by the Seller in writing and the performance of any such
contract or order by the Seller shall not be deemed to be an
acceptance of any terms of the Buyer by the Seller.
Article II
Unless otherwise provided for in these Standard Sales Terms,
the relationship between the Seller and the Buyer shall be
governed by the provisions of applicable law.
3. The Buyer shall not have the right to retain any payment
due to the Seller for any reason whatsoever and shall not
deduct from any moneys due to the Seller any money owed
or allegedly owed by the Seller to the Buyer unless any such
counterclaim is undisputed by the Seller or has been
awarded to the Buyer by a judgment from which no appeal
can be taken.
If these Standard Sales Terms are otherwise inapplicable or
ineffective for any reason whatsoever, the sale of any goods
delivered by the Seller to the Buyer (“the Goods”) shall be
subject to the reservations of Clause 6 in Article V hereinbelow.
Article I
General Terms
1. Any bid or offer submitted by the Seller to the Buyer shall
not be binding upon the Seller and unless otherwise
expressly agreed upon by the Seller and the Buyer, no
contract placed by the Buyer shall be effective unless
expressly accepted by the Seller in writing.
2. The title to any sample, drawing or other document or
information, whether reduced to writing or in electronic
form, including but not limited to any copyrights or other
rights associated therewith, which may be provided by the
Seller to the Buyer shall remain vested in the Seller and no
such sample, drawing or other document or information
may be made accessible by the Buyer to any third party.
3. Any performance or other data or description of any Goods
by the Seller in any brochure, price list, bid, proposal, offer
or any other document which may form part of any such
bid, proposal or offer shall be deemed to be approximate in
accordance with standard industry practices and shall not be
binding upon the Seller unless expressly accepted as binding
by the Seller and the Seller does not make any warranties
whatsoever with respect to any properties of any of the
Goods.
4. Commercial terms agreed between the Seller and the Buyer
shall be interpreted in accordance with Incoterms 2000.
122
Price and Payment
1. Unless expressly otherwise agreed upon, any price agreed
between the Seller and the Buyer shall be ex works exclusive
of any packaging. Each such price shall be exclusive of any
sales tax which shall be billed by the Seller in addition to
said price at the rate which may be applicable at any time
and from time to time.
2. Unless otherwise agreed upon, the price of any of the Goods
shall be paid without any deduction for any reason
whatsoever as follows:
- One third upon the receipt of the Seller’s acceptance of the
contract placed by the Buyer
- One third upon the receipt by the Buyer of the Seller’s
notice that all main components of the Goods are ready for
shipment
- The remaining sum upon the transfer of the risks of the
Goods to the Buyer and upon the issuance of the Seller’s
final invoice for the Goods
4. If, during the period between the date on which any contract
was awarded by the Buyer to or any order was placed by the
Buyer with the Seller and the date on which production for
the performance of said contract or order commences, any
labor, material and/or production costs associated with said
contract or order increase for any reason for which the Seller
is not liable and the cost of any of the Goods (as defined in
Section 255 of the German Commercial Code) as determined
in accordance with generally accepted German accounting
principles is shown by the Seller to have risen by more than
twenty percent (20%) since the date of contract award or
order placement, then the Seller shall have the right to
redetermine the price of any such Goods payable by the
Buyer under said contract or order provided however that
the Seller shall not be entitled to increase said price by more
than the increase in said cost.
5. The Buyer shall pay any amount owing to the Seller within
seven (7) calendar days from the due date for the payment
of said amount.
Article III Delivery Time and Late Delivery
1. The time available to the Seller for the delivery of the Goods
(“Delivery Time”) shall be as agreed between the Parties in
the contract placed. The Seller shall not be obligated to
deliver within said Delivery Time unless all technical and
commercial details have been agreed upon order placement
and the Buyer performs all of its obligations under said
contract or order such as, without limitation, any obligation
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)
to obtain necessary certificates, approvals or permits from
agencies or authorities and the obligation to make any
advance payment provided that any non-satisfaction of any
of the preceding conditions shall operate to increase the
Delivery Time reasonably and further provided that no delay
for which the Seller may be liable shall operate to increase
the Delivery Time.
2. The Seller shall not be obligated to deliver any Goods
within the Delivery Time unless the Seller receives deliveries
from its suppliers as and when ordered by the Seller
provided that the Seller shall notify the Buyer as soon as
reasonably possible of any delay in delivery it may become
aware of.
3. The Seller shall be deemed to have delivered within the
Delivery Time if the Goods have left the Seller’s works prior
to the expiry of the Delivery Time or the Seller has notified
the Buyer prior to the expiry of the Delivery Time that the
Goods are ready for Delivery.
4. If the Buyer fails to make any payment to the Seller under
any contract or order whatsoever when said payment is due,
the Seller shall, upon notice to the Buyer, have the right to
discontinue performance under the contract awarded or the
order placed for the Goods until the payment the Buyer has
failed to make when due has been received provided
however that the Seller shall not have said right if the
payment so due but not made is immaterial.
5. If the Seller is unable to deliver any Goods within the
Delivery Time for reasons of force majeure, due to any labor
dispute or due to any circumstances beyond the reasonable
control of the Seller then the Delivery Time shall be
extended reasonably. The Seller shall notify the Buyer of the
commencement and the end of any such circumstances as
soon as may be reasonably possible.
Article IV Transfer of Risk and Acceptance
1. Unless expressly otherwise agreed upon between the Seller
and the Buyer, the Goods shall be delivered ex works.
2. If the Goods to be delivered by Seller to the Buyer are
divisible, then the Seller shall have the right to deliver and
to invoice to the Buyer said Goods in reasonable parts and
the Buyer shall not have the right to retain payment for any
such reasonable part on the grounds of the non-delivery of
any other parts of the Goods.
3. If any delivery by the Seller to the Buyer requires acceptance
by the Buyer under any express provision of the order
placed by the Buyer or at law, then any delivery by the Seller
to the Buyer shall be deemed to have been accepted by the
Buyer if and in as far as
- any Goods manufactured or processed by the Seller are,
after delivery, sold to or allowed to be used by any third
party or
- any Goods manufactured or processed by the Seller are,
123
after delivery, processed or mixed or combined with any
other things with the agreement of the Buyer or
- any Goods manufactured or processed by the Seller are,
beyond trials or tests, used by the Buyer or by any third
party with the agreement of the Buyer or
- the Goods are accepted by any purchaser from the Buyer
whatever may be earlier provided that any prior acceptance
under the contract awarded or the order placed by the Buyer
or at law shall take precedence over any acceptance under
this Clause.
Article V
Retention of Title
1. The title to all Goods delivered by the Seller to the Buyer
shall remain vested in the Seller until the full payment of all
accounts receivable by the Seller from the Buyer for any
reason whatsoever provided that under current account
arrangements the title so retained shall be deemed to be
security for any balance owed to the Seller.
The Buyer shall not dispose of any of the Goods the title to
which is so vested in the Seller (“Title Reservation Goods”)
other than in the Buyer’s ordinary course of business
provided that the Buyer shall no longer have the right so to
dispose of any Title Reservation Goods if and as soon as the
Buyer fails to make payments when payments are due. The
Buyer shall not have the right to pledge or to transfer by
way of security the title to any Title Reservation Goods. The
Buyer shall be obligated to maintain the rights of the Seller
if the Title Reservation Goods are sold by the Buyer to any
third party under credit arrangements. The Buyer shall
promptly notify the Seller of any lien of attachment,
execution or garnishment or any seizure or the like relating
to any Title Reservation Goods.
The Buyer hereby assigns to the Seller and the Seller hereby
accepts the Buyer’s assignment of any title to payment for
any of the Goods resold by the Buyer to any purchaser and
any security received by the Buyer from any such purchaser
for any such payment provided however that the Buyer
shall, subject to any notice to the contrary given by the
Seller, have the right to collect any such payment and to
enforce any such security at its cost. Upon the request of the
Seller, the Buyer shall notify the Seller of the debtors against
which titles to payment so assigned are held, the securities
provided therefor, the type and the amount of the debt of
each such debtor and the type and the amount of each such
security and deliver to the Seller all documents which may
be necessary to collect any amount so owed by any such
debtor. Upon notice to the Buyer, the Seller shall have the
right to notify any such debtor of the assignment of the title
to payment by the Buyer to the Seller hereunder.
2. If the Goods are sold by the Buyer to any purchaser together
with any other goods the title to which is not vested in the
Seller, then a share of the full title to payment of the Buyer
under said sale to said purchaser equal to the price of said
Goods agreed between the Buyer and the Seller shall be
deemed to have been assigned by the Buyer to the Seller.
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)
3. Upon the request of the Buyer, the Seller shall waive any
title to Goods delivered by the Seller to the Buyer in as far as
the value of all Goods the title to which has been retained by
the Seller hereunder exceeds one hundred ten percent
(110%) of the value of all titles to payment the Seller holds
against the Buyer.
4. The Buyer shall, as of the transfer of risks associated with
Title Reservation Goods, insure all Title Reservation Goods
against any damage or loss or destruction as a result of any
fire, inundation, flooding or theft or any destruction or loss
or damage in transit provided that the Buyer shall notify the
Seller promptly of any such destruction or loss or damage
and shall, upon the request of the Seller, provide to the
Seller any documentation of any such loss or damage such
as, without limitation, any expert report on said destruction
or loss or damage, the names of the insurers of said Goods
and, as requested by the Seller, the insurance policy or
policies relating to the Title Reservation Goods or insurance
certificates issued by the insurer or the insurers for the Title
Reservation Goods. The Buyer hereby assigns to the Seller,
conditionally as of the time of any such destruction or loss
of or damage to any Goods, any title against any insurer or
any party liable for any such destruction or loss or damage
to a maximum amount equal to the price agreed for any
such Goods affected by any such destruction or loss or
damage by way of security for all moneys owed by the
Buyer to the Seller.
5. Any processing of any Title Reservation Goods by the Buyer
shall be for the Seller and the Seller shall be deemed to be
the processor for the purposes of Section 950 of the German
Civil Code. If Title Reservation Goods are processed,
combined or mixed with other goods the title to which is not
vested in the Seller, then a fraction of the title to the new
product equal to the ratio between the price invoiced to the
Buyer for the Goods so processed, combined or mixed and
the sum of the price invoiced to the Buyer for the Goods so
processed, combined or mixed and the price or prices
invoiced to the Buyer for the other goods so processed,
combined or mixed shall be vested in the Seller. The Buyer
shall be the custodian of any such new product the title to
which is vested in the Seller in total or in part for the Seller.
If any such Title Reservation Goods are processed, combined
or mixed with goods of the Buyer and the goods of the
Buyer are the main constituents of the new product thereby
created, then the Buyer shall be deemed to have transferred
to the Seller a fraction of the title to any such new product
computed in accordance with the principles of the preceding
sentence and shall be the custodian of said new product for
the Seller.
The provisions of Clauses 1 through 4 hereinabove
applicable to Title Reservation Goods shall apply mutatis
mutandis to any new product obtained by processing,
combination or mixing in which the Seller acquires in total
or in part a title through the operation of this Clause.
6. If these Standard Sales Terms have not been agreed
effectively, any transfer of title to any of the Goods shall be
124
subject to the Seller receiving the full price agreed between
the Seller and the Buyer therefor.
Article VI Defects
1. General
1.1 If Section 377 or Sections 377 and 381 of the German
Commercial Code (sales and contract manufacture
agreements between business organizations as defined in
Section 1 et seq, of the German Commercial Code) are
applicable to the order placed, the Buyer shall notify the
Seller promptly of any patent defect in any of the Goods
provided that said notice shall be given no later than on the
fourth (4th) working day following the delivery of said
Goods. Any latent defect in any of said Goods shall be
notified promptly by the Buyer to the Seller provided that
said notice shall be given no later than on the fourth (4th)
working day following the discovery of said defect. Each
such notice of any defect in any of the Goods shall be in
writing. The conditions applicable to any such notice and
the effects of a late notice of any defect in any of the Goods
shall furthermore be governed by the conditions of law
(Sections 377, respectively 377 and 381 of the German
Commercial Code),
1.2 If the Buyer is not a business organization, notice of any
patent defect in any of the Goods delivered by the Seller to
the Buyer shall be given by the Buyer to the Seller within
two (2) weeks following the delivery of said Goods in the
case of sales and contract manufacture agreements and
within two (2) weeks following acceptance in the case of
service agreements. The term provided for hereinbefore shall
be deemed to have been complied with if said notice is
forwarded by the Buyer within said term and received by
the Seller within four (4) weeks from such delivery or
acceptance as the case may be. The Buyer shall not be
entitled to any remedy for any patent defect in any of the
Goods if the Buyer fails to give notice as aforesaid unless
and in as far as
- the Seller is liable for said defect due to willful act, neglect
or omission, any act of bad faith or any gross negligence,
- said defect is covered by a warranty of the Seller in
accordance with Section 443 of the German Civil Code or
- said defect is claimed in connection with loss of human
life, injury, impairment of health or loss of freedom
provided that any liability of the Seller for any such defect
shall be excluded in accordance with the provisions of law
such as but not limited to the provisions of Section 640,
paragraph 2, or Section 442 of the German Civil Code if the
Buyer had known said defect or did not know said defect
due to its own gross negligence.
2. Product Defects
2.1 If any of the Goods delivered by the Seller to the Buyer is
defective, the Seller shall remedy said defect by repair or
replacement. If said remedial action fails, then, subject to the
provisions on damages in Article VII hereinbelow, the Buyer
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)
shall be entitled to any of the remedies provided for by law.
3. Legal Defects
2.2 If any remedial action is taken by the Seller, then the Seller
shall bear all costs and expenses occasioned by the removal
of said defect such as, without limitation, any transportation
or traveling expenses or any labor or material costs provided
however that any extra costs occasioned by the Buyer
moving the Goods after delivery to a place other than the
registered premises of the Buyer shall be carried by the
Buyer unless the removal of said Goods is a use for which
the Goods are intended.
3.1 The liability of the Seller for the Goods not to be in breach
of any third-party industrial property rights or copyrights
shall be limited to the Federal Republic of Germany and the
country in which the Buyer is registered. The Seller shall
have no such liability for any other country, such as any
country to which the Goods may be moved by the Buyer,
unless such other country has been notified by the Buyer to
the Seller prior to awarding the contract or placing the order
for the Goods.
2.3 The Buyer shall give the Seller the time and the opportunity
which may be needed to remove any defect in any of the
Goods provided that the Seller shall not be held liable for
any consequences of not being given such time and
opportunity.
3.2 If the use of the Goods delivered by the Seller to the Buyer is
in breach of any third-party industrial property rights or
copyrights and the Seller is liable for said breach according
to Clause 3.1 hereinabove, the Seller shall, at its cost, obtain
for the Buyer the right to continue the use of said Goods or
modify said Goods in a manner reasonably acceptable to the
Buyer so that said Goods will no longer be in breach of any
such industrial property rights or copyrights. If such rights
cannot be obtained at reasonable commercial terms or
within a reasonable period of time and if the Goods cannot
be so modified, then the Buyer shall have the right, at its
discretion, to rescind the contract awarded by the Buyer to
the Seller or the order placed by the Buyer with the Seller or
to obtain from the Seller a reasonable reduction in the price
of said Goods.
2.4 Any repair or replacement by the Seller with respect to any
Goods shall irrespective of the scope of any such repair or
replacement not be deemed to be an acceptance of any
liability for any defect in any of the Goods claimed by the
Buyer provided that no persons other than legal
representatives or procurators under Sect. 49 German
Commercial Code (“Prokuristen”) of the Seller shall have the
right to accept any liability for any defect on behalf of the
Seller.
2.5 If any defect in any of the Goods claimed by the Buyer
shows not to be a defect for which the Seller is liable, then
the Buyer shall reimburse to the Seller all costs reasonably
incurred by the Seller to remove said alleged defect in good
faith provided that material and labor costs so incurred by
the Seller shall be reimbursed at the Seller’s standard rates
applicable at the time when the alleged defect was so
removed.
2.6 The Buyer shall not be entitled to the removal by the Seller
of any defect due to any of the following:
- Improper use of any Goods or use of any Goods for a
purpose for which the Goods are not fit or defective
installation or commissioning of the Goods by the Buyer or
any third party
- Natural wear and tear, improper or negligent handling,
improper maintenance or use of any unfit consumables or
utilities
- Defective construction work, unsuitable foundations or
chemical, electrochemical or electrical interference unless
caused by the Seller
2.7 The Seller shall not be held liable for the consequences of
any improper or inappropriate removal of any defect in any
of the Goods by the Buyer or any third party or any
modification to any of the Goods made without the Seller’s
prior consent.
125
The Seller shall in any such event further indemnify the
Buyer against any undisputed claims or any claims
determined by non-appealable court decision of the owners
of such industrial property rights or copyrights.
3.3 Subject to Clause 3.4 hereinbelow, the Buyer shall not have
the rights under Clause 3.2 hereinabove, unless
- the Buyer notifies the Seller promptly of any breach of
industrial property rights or copyrights claimed by any
third party,
- the Buyer reasonably supports the defense of any such
claims by the Seller and allows the Seller to make
modifications as referred to in Clause 3.2 hereinabove,
- the Buyer allows the Seller to defend at its own cost any
such claim or to make any out-of-court settlement with
respect to any such claim as the Seller may think fit,
- the legal defect is not due to any instructions given by the
Buyer to the Seller and
- the legal defect is not due to any modification of the Goods
by the Buyer or any use of the Goods not in conformity
with the intended use.
3.4 Notwithstanding the limitations in Clauses 3.2 and 3.3
hereinabove, the provisions laid down by law shall apply, if
and in as far as
- the title of the Buyer against the Seller is held under Section
478 or under Sections 651 and 478 of the German Civil Code,
- the Seller is liable for the breach of the industrial property
rights or the copyrights due to any willful act, neglect or
omission or any gross negligence on the part of the Seller,
- the Seller warranted (as provided for in Section 443 of the
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)
German Civil Code) that the Goods will not violate any
industrial property rights or copyrights or
- any damages claimed as a result of any breach of any
industrial property rights or copyrights are on the grounds
of any loss of life, injury, loss of health or loss of freedom.
German Product Liability Act or
- if and in as far as the Seller is held liable under any
warranty in accordance with Section 443 of the German
Civil Code agreed by the Seller to provide security to the
Buyer with respect to the loss or damage incurred by the
Buyer.
4. Warranties Under Section 443 of the German Civil Code
No person other than a legal representative or a procurator
under Sect. 49 German Commercial Code (“Prokuristen”) of
the Seller will have the right to agree any warranties
according to Section 443 of the German Civil Code.
Article VII
Liability and Damages
1. The Seller shall be liable for any willful acts, neglects and
omissions and any gross negligence of its legal
representatives and/or any other persons authorized by the
Seller to perform any of the obligations of the Seller under
any contract awarded to the Seller or order placed with the
Seller (“Agent or Employee”).
2. In the event of any ordinary negligence of any legal
representative, Agent or Employee of the Seller, the liability
of the Seller shall be limited to liability for any loss or
damage the Seller foresaw when the contract was awarded
or the order was placed by the Buyer or should have
foreseen when the contract was awarded or the order was
placed by the Buyer considering the circumstances the Seller
knew or should have known when the contract was awarded
or the order was placed by the Buyer.
If and in as far as any loss or damage suffered by the Buyer
due to the ordinary negligence of any legal representative,
Agent or Employee of the Seller is compensated by any final
payment by any insurer under any insurance contract
against loss or indemnity concluded by the Buyer or for the
Buyer such as, but not limited to any liability, all-risks,
transportation, fire or business interruption insurance, the
liability of the Seller shall be limited to any losses incurred
by the Buyer as a result of any such insurance claim such as,
without limitation, any increase in insurance premium. Any
liability of the Seller for any loss or damage caused by the
ordinary negligence of any of the legal representatives,
Agents or Employees of the Seller and covered by a final
insurance payment to the Buyer shall be excluded.
Subject to the limitations provided for hereinbefore, any
liability of the Seller for any loss or damage caused by the
ordinary negligence of any legal representative, Agent or
Employee of the Seller shall for each incident be limited to
an amount of two hundred fifty thousand Euros (250,000 1).
3. The exclusions and limitations of liability provided for
hereinabove shall not apply,
- if and in as far as the Seller is held liable for any human
loss of life, injury or loss of health,
- if and in as far as the Seller is held liable under the
126
4. The provisions of Clauses 1 through 3 hereinabove shall not
operate to alter any of the provisions of law regarding the
onus probandi.
Article VIII
Limitation
1. The period of limitation with respect to any defect shall be a
period of one (1) year provided that said period shall be five
(5) years for any defect in any Goods serving as civil
engineering structure or structures or any defect in any civil
engineering structure caused by any Goods ordinarily used
in civil engineering structures.
2. The period of limitation with respect to any other cause
under the contract awarded or the order placed by the Buyer
or any other cause outside said contract or order shall be a
period of eighteen (18) months.
3. Notwithstanding the provisions of Clauses 1 and 2 hereinabove, the periods of limitation allowed by law shall apply,
if and in as far as
- the title held by the Buyer against the Seller is under
Section 478 or Sections 651 and 478 of the German Civil
Code,
- the title of the Buyer is held on the grounds of any willful
act, neglect or omission, any act of bad faith or any gross
negligence on the part of any of the legal representatives,
Agents or Employees of the Seller,
- the title held by the Buyer against the Seller is on the
grounds of any loss of life, injury, loss of health or loss of
freedom of any person,
- the title held by the Buyer against the Seller is under the
German Product Liability Act,
- the title held is on the grounds of a third party title in rem
which grants any such third party a title to the surrender
of the Goods (Sect. 438 para.1 subsubpara. a German Civil
Code) or
- the title held is on the grounds of any title recorded in any
register of deeds (Sect. 438 para.1 subpara. b German Civil Code).
The provisions in Clauses 1 and 2 shall further not apply if
the title is held by the Buyer under a warranty of the Seller
in accordance with Section 443 of the German Civil Code
provided that any such title shall exclusively be subject to
the provisions of Clause 4 hereinbelow.
4. The period of limitation applicable to any warranty of the
Seller in accordance with Section 443 of the German Civil
Code shall commence upon the delivery of the Goods to the
Buyer or, if acceptance by the Buyer is required by law,
upon the acceptance of the Goods by the Buyer provided
that, in the event of bad faith, said period shall commence as
provided for in Section 438, paragraph 3, of the German
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)
Civil Code. Said period shall terminate as provided for in
Section 438 of the German Civil Code unless a shorter
period has been agreed according to the terms of the
warranty under Section 443 of the German Civil Code.
5. Clauses 1 through 4 hereinabove shall not operate to alter
any of the provisions of Sections 196, 197 and 479 of the
German Civil Code or any of the provisions of law applicable
to the onus probandi.
Article IX
Software Use
If the contract awarded by the Buyer to the Seller or the order
placed by the Buyer with the Seller provides for the supply of
software, the Buyer will be granted a non-exclusive right to use
said software and any documentation of said software. Said
software will be supplied by the Seller to the Buyer for use with
the Goods delivered by the Seller to the Buyer provided that the
Buyer shall not have the right to use said software on more than
one system.
Any copying, modification or translation of said software or any
conversion of the object code of said software into source code
shall be limited as provided for in Section 69 et seq. of the
German Copyright Act. The Buyer agrees not to remove from
said software any reference to the developer of said software
such as, without limitation, any copyright reference and not to
modify any such reference unless the prior express content of
the Seller has been obtained.
Any other rights associated with such software and any
documentation of said software and any copies thereof shall
remain vested in the Seller or the supplier of said software as
the case may be. The Buyer shall not grant any sub-license.
Article X
Applicable Law and Jurisdiction
1. The relationship between the Seller and the Buyer shall
exclusively be governed by the law of the Federal Republic
of Germany as the same may be applicable to the
relationship between two German parties provided however
that the application of the United Nations Convention on
Contracts for the International Sale of Goods of 11 April 1980
shall be excluded.
2. If the Buyer is a business or any public-law legal person or
other entity, any dispute between the Seller and the Buyer
shall be settled by the courts having jurisdiction at the
registered offices of the Seller provided however that the
Seller shall have the right to bring action against the Buyer
in the courts having jurisdiction at the registered offices of
the Buyer.
3. If any of the terms and conditions of the Contract or these
Standard Sales Terms is or become ineffective, the
remaining provisions of the Contract and these Standard
Sales Terms shall remain in full force and effect. Any such
ineffective provision shall be deemed to have been replaced
by the Seller and the Buyer by an effective provision which
127
shall have commercial, financial and economic implications
which shall be as close to those of said ineffective provision
as may be reasonably.
Notes
129
GEA Tuchenhagen
We live our values.
Excellence • Passion • Integrity • Responsibility • GEA-versity
GEA Mechanical Equipment
GEA Tuchenhagen GmbH
Am Industriepark 2-10, 21514 Büchen, Germany
Phone +49-4155 49-0
sales.geatuchenhagen@gea.com, www.gea.com
GEA Tuchenhagen-Pumps 07/2014
GEA Group is a global engineering company with multi-billion euro sales and operations in more than
50 countries. Founded in 1881, the company is one of the largest providers of innovative equipment and
process technology. GEA Group is listed in the STOXX® Europe 600 Index.
Download
Study collections