Curv Perforated Housing

advertisement
Cûrv Perforated
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
CHIT
S
SORS
AR
C
Project Name
Type
Catalog No.
Date
EN
E
Project Information
TURAL
Construction
Labels and Electrical
—Up to four T8 lamps and up to three T5 or T5HO
lamps.
— Quick-connect plugs standard.
—Housing provides indirect distribution. Glow from
perforation allows under 5% direct light.
Features
• 2½" deep housing for a sleek modern appearance
• Indirect Luminaire
• Unique lamp crossing technique on one and three
lamp models maintains 48" modularity
• Heavy 20-gauge steel construction provides
excellent housing rigidity
• Controls compatible
• Available with optional installed open or closed loop
daylight sensors (DSPL, DSL) when daylight dimming
systems are desired
• Unique die cast aluminum, tongue and groove
couplers provide zero tolerance alignment resulting
in consistently straight rows
• Patented die cast aluminum end caps for a soft
finished appearance (Patent# 6,796,676B2)
• Flat end caps standard
• Available with a slotted or perforated housing
• Modular mounting points for convenient hanging
locations
• Available with exclusive wiHUBB technology
preinstalled (WIH option)
– Peer to peer, self-healing wireless mesh network
– Integrated control system for 0-10VDC or step dimming, or On/Off
—All luminaires are built to UL1598 Standards and bear
appropriate UL and cUL or CSA labels. Damp location
labeling is standard.
—The exact shape of the housing is maintained by the
use of an inner die cast plate at each fixture end.
—Reflectors: standard with a painted white steel
reflector with specular inserts on the side.
architectural sensors installed
—High efficiency reflector (HRF) high reflectance
specular material allows for wide distribution with
maximum efficiency.
Daylight sensors are used to measure available sunlight
and reduce electric light for energy savings. Alera
sensors are installed to be both accessible and visible
below the housing.
—WR: An economical painted white reflector
9½"
The housing and all painted parts are treated with a
multi-stage phosphate bonding process before being
finished. Parts are then finished with a white RAL
powder coat finish for maximum consistent coverage
and longevity.
—Aircraft cable suspension mechanism.
Additional technical data: see TID sheets, Alera website
and sensor manufacturer websites.
Name:
Test #:
Efficiency:
LER:
Housing type
PERF Perforated
HSLT Horizontal
Slot Strip
VLST Vertical Slot
Strip
LAMP TYPE AND PROFILE
1T5 One T5 Lamp
2T5 Two T5 Lamps
3T5 Three T5 Lamps
1T5HO One T5HO Lamp
2T5HO Two T5HO Lamps
3T5HO Three T5HO Lamps
2T8 Two T8 Lamps
3T8 Three T8 Lamps
4T8 Four T8 Lamps
Specify voltage. For additional, specify quantity before
nomenclature (Example: 2EL120).
Not available with all configurations; some limitations apply.
Contact factory for details.
3
One extra feed drop per EMC or NLC. (For through wiring,
contact factory.)
4
Lutron EcoSystem® series ballast. Contact factory for other
Lutron ballasts.
5
Ships separately.
1
2
Page 1/4 Rev. 06/30/13
CV-1T8-S-E-WR
12991
97.2%
86
Example: CV-8-2T8-PERF-CM48-EU-MW
—
Row length
4' Single
8' Single
12' Single
Indicate row length
over 12' in 4'
increments
Note: Rows over 12' will
be configured by Alera.
Example: 16' will be (2) 8'.
Alternate configurations:
contact factory.
4
8
12
—
DSL: Lutron EcoSystem, digital dimming ballast.
Open loop sensor must be pointed directly at the
source of natural light. System requires proprietary
commissioning by others.
Mounting
Ordering Information
Model
CV Cûrv
DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast.
Closed loop sensor measures reflected light in a cone
below the sensor. Pre-commissioned by Philips to 45fc
standard; modest manual adjustability via sensor ring.
Finish
End of cable barrel screws into a standard ¼-20
bolt brought down from the ceiling. A feed canopy
is provided for each feed location. All fixtures are
suspended in modular increments and must be
supported at each fixture-housing end.
2½"
—
Controls compatible. When used with Occupancy
Sensors, most lamp vendors recommend Program
Start ballast (EP) to extend lamp life. Common control
schemes: wiHUBB Enabled (WIH) switching (L/R or
IBOB), 0-10V dimming ballast (ED), Step Dimming
ballast (ESD), wiHUBB Enabled (WIH). Compatibility
with specific control (example, dimmer switch) is by
others. wiHUBB antenna will be visible. For daylight
sensors installed, see information below.
—The housing is designed to wrap around the end
plates and secures on top with concealed screws to
ensure housing tolerances are consistent. These die
cast aluminum end caps and aligners provide zero
tolerance alignment between fixtures, resulting in
consistently straight rows with no snaking.
—Fixed cable has a total vertical adjustment
of 1¼".
Shape and Dimensions
CV —
controls compatibility
—
MOUNTING Method
FCM18 Fixed Aircraft
Cable Mount
(Non-adjustable,
Std.) 18"
CM Adjustable
Aircraft Cable
Mount
—
Adjustable
Cable length
48 48"
96 96"
Other lengths
available on
request.
Ballast
E Electronic, Instant Start (Std. for T8)
EP Electronic, Programmed Start (Std. for T5
& T5HO, optional for T8)
ELW Electronic T8, Low Wattage, Instant Start
EPLW Electronic T8, Low Wattage, Programmed
Start
ED Electronic, Dimming (Must specify)
ESD Electronic, Step Dimming
EDUMK7 Universal Voltage, Electronic Dimming
Philips Advance Mark 7 (0-10V)
EDULUTES Universal Voltage, Lutron EcoSystem
Digital Dimming Ballast 2, 4
Unless specified, Alera will use fewest ballasts possible.
—
U
120
277
347
Voltage
120V-277V
120V
277V
347V
—
Finish
MW Matte White (Std.)
ZT ZET Metallic Silver
See Color Selection Guide
for other colors.
Options
WR
HRF
DC
SCE
BN
LR
IBOB
F0841
F5841
F0835
F5835
EL
EMC
NLC
GLR
GMF
TBAR
WIH
DSPL
White Reflector
High Efficiency Reflector
Dust Cover (N/A T5HO)5
Sculpted End Cap (55⁄16")5
Bull Nose End Cap (51⁄16")5
Left/Right Switching (2-Lamp only)
Inboard/Outboard Switching (3-Lamp only)
With T8 4100L Lamp Installed
With T5(HO) 4100K Lamp Installed
With T8 3500K Lamp Installed
With T5(HO) 3500K Lamp Installed
One Emergency Battery Pack1, 2
One Emergency Circuit 2, 3
Night Light Circuit 2, 3
Fast Blow Fuse
Slow Blow Fuse
T-Bar Mounting
wiHUBB Enabled 2
Philips LuxSense Daylight Sensor (Must Specify Philips
Advance 0-10V Dimming Ballast)2
DSL Lutron Daylight Sensor (Must Specify Lutron EcoSystem
(EC5 Series)Dimming Ballast)2, 4
Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specifications subject to change without notice.
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Curves / CV PERF
Cûrv Perforated
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Cross section
2½"
2½"
9½"
CV-2T8 PERF
2½"
9½"
CV-3T8 PERF
9½"
CV-4T8 PERF
2½"
2½"
9½"
CV-1T5, T5HO PERF
2½"
9½"
CV-2T5, T5HO PERF
9½"
CV-3T5, T5HO PERF
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-2T8-PERF-CM-E
Cûrv Architectural Curve
9.5" × 48" 2-Lamp with
LS Side Reflector
REL2P32SC
0.87
F32T8
2900
59
Pendant
0º = 90 90º = 90
0º = 1.16 90º = 1.31
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
369
330
301
274
244
225
203
174
189
178
159
211
369
351
325
300
287
273
258
283
296
320
425
634
369
362
349
352
387
386
387
392
431
498
584
952
369 369
372 372
397 409
430 443
444 459
450 482
461 498
480 523
539 566
605 676
743 796
1269 1374
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
31
51
93
133
1775
2680
4286
5421
5555
0.5
0.9
1.6
2.3
30.6
46.2
73.9
93.5
95.8
0.6
0.9
1.7
2.4
32.0
48.3
77.2
97.6
100.0
RCR
Luminaire
Angle
Luminaire Data Test 13197
RC
RW
1
2
3
4
5
6
7
8
9
10
70
83
76
69
63
58
53
48
45
41
38
80
50 30
80 76
69 64
61 54
54 47
47 40
42 35
38 31
34 27
31 24
28 21
10
73
59
49
41
35
30
26
22
20
17
70
71
65
59
54
49
45
41
38
35
33
70
50 30
68 66
60 55
52 47
46 40
41 35
36 30
33 27
29 24
26 21
24 19
10
63
52
43
36
31
26
23
20
17
15
50
47
41
36
32
28
25
23
21
19
17
50
30
46
39
33
29
25
22
19
17
15
13
10
44
36
30
26
22
19
16
14
12
11
Indoor Candela Plot
0
0
2
1
1
1
1
1
1
1
1
0
180 165
1500
150
120
750
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
750
Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
95.8%
82
Yes-VDT Intensive Use
$2.93 based on 3000 hrs.
and $0.08 per KWH
135
60
1500
0
15
30
Horiz 0-180
90.0
45.0
0.0
45
Test Date 8/22/02
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-2T8-PERF-E-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp
with Perforated Highly
Specular Reflector
B232I120RH-A
0.88
F32T8
2900
59
Pendant
0º = 90 90º = 90
0º = 1.09 90º = 1.09
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
101
85
84
78
72
64
55
44
0
0
0
0
101
74
60
52
57
48
37
44
27
0
0
0
101
74
72
78
72
64
74
65
54
36
0
0
101
85
84
91
86
96
92
87
81
71
53
0
101
85
84
91
86
96
92
87
81
71
53
106
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
7
12
20
32
1871
2898
4499
5337
5369
0.1
0.2
0.3
0.6
32.3
50.0
77.6
92.0
92.6
0.1
0.2
0.4
0.6
34.8
54.0
83.8
99.4
100.0
RCR
Luminaire
Angle
Luminaire Data Test 12982
RC
RW
1
2
3
4
5
6
7
8
9
10
70
80
73
66
61
55
51
47
43
40
37
80
50 30
77 73
67 62
59 52
52 45
46 39
41 34
36 30
33 26
29 23
27 21
10
70
57
47
40
34
29
25
21
19
16
70
68
62
57
52
47
43
40
37
34
32
70
50 30
66 63
57 53
50 45
44 39
39 34
35 29
31 26
28 23
25 20
23 18
10
60
50
41
35
29
25
22
19
16
14
50
45
39
35
31
27
24
22
19
18
16
50
30
43
37
31
27
24
21
18
16
14
13
10
42
35
29
24
21
18
15
13
12
10
Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0
180
165
150
120
850
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
850
Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
135
1700
60
92.6%
80
Yes-VDT Intensive Use
$3.00 based on 3000 hrs.
and $0.08 per KWH
1700
0
0.0
15
30
Horiz 0-180
90.0
45.0
Page 2/4 Rev. 06/30/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
45
Test Date 12/12/01
Curves / CV PERF
Cûrv Perforated
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-3T8-PERF-E-HRF
Cûrv Architectural Curve
9.5" × 48" 3-Lamp
with Perforated Highly
Specular Reflector
B332I120RHA
0.88
F32T8
2900
88
Pendant
0º = 90 90º = 90
0º = 1.19 90º = 1.01
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
313
287
277
274
258
225
203
174
162
142
106
211
313
245
217
208
201
209
203
196
189
178
212
211
313
234
241
248
258
241
258
262
269
285
318
423
313
245
265
274
272
289
295
305
323
320
371
529
313
255
265
274
287
305
295
327
323
356
425
634
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
23
37
66
98
2312
3778
6361
7757
7855
0.3
0.4
0.8
1.1
26.6
43.4
73.1
89.2
90.3
0.3
0.5
0.8
1.3
29.4
48.1
81.0
98.7
100.0
RCR
Luminaire
Angle
Luminaire Data Test 12985
RC
RW
1
2
3
4
5
6
7
8
9
10
70
78
71
65
59
54
50
46
42
39
36
80
50 30
75 71
65 60
57 51
50 44
45 38
40 33
35 29
32 25
29 23
26 20
10
69
56
46
39
33
28
24
21
18
16
70
67
61
55
50
46
42
39
36
33
31
70
50 30
64 61
56 52
49 44
43 38
38 33
34 29
31 25
27 22
25 20
23 18
10
59
48
40
34
29
25
21
18
16
14
50
44
39
34
30
27
24
21
19
17
16
50
30
43
36
31
27
23
20
18
16
14
12
10
41
34
28
24
20
17
15
13
11
10
Indoor Candela Plot
0
0
1
1
1
0
0
0
0
0
0
0
180
165
150
135
2400
120
1200
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
1200
Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
90.3%
79
Yes-VDT Intensive Use
$3.04 based on 3000 hrs.
and $0.08 per KWH
60
2400
0
15
30
Horiz 0-180
90.0
45.0
0.0
45
Test Date 12/4/01
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-1T5HO-PERF-CM-EP
Cûrv Architectural Curve
9.5" × 48" 1-Lamp with
LS Side Reflectors
ICN2S54
1.00
F54T5
4400
63
Pendant
0º = 90 90º = 90
0º = 1.13 90º = 1.30
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
295
255
241
222
186
177
147
131
135
142
159
211
295
266
253
235
215
209
184
196
216
214
265
423
295
277
277
274
287
305
295
305
296
320
371
634
295
287
313
326
344
353
350
371
404
427
478
846
295
298
325
339
358
369
369
392
404
463
584
952
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
24
40
72
101
1617
2295
3461
4259
4360
0.6
0.9
1.6
2.3
36.8
52.2
78.7
96.8
99.1
0.6
0.9
1.7
2.3
37.1
52.7
79.4
97.7
100.0
RCR
Luminaire
Angle
Luminaire Data Test 13188
RC
RW
1
2
3
4
5
6
7
8
9
10
70
86
78
71
65
60
55
50
46
43
40
80
50 30
82 79
72 66
63 56
55 48
49 42
44 36
39 32
35 28
32 25
29 22
10
75
62
51
43
36
31
27
23
20
18
70
74
67
61
56
51
47
43
40
37
34
70
50 30
71 68
62 57
54 49
48 42
42 36
38 31
34 28
30 24
27 22
25 19
10
65
53
44
37
32
27
23
20
18
16
50
49
43
38
33
29
26
24
21
19
18
50
30
47
40
34
30
26
22
20
17
15
14
10
46
38
31
27
23
19
17
15
13
11
0
0
2
1
1
1
1
1
1
1
1
0
Indoor Candela Plot
150
135
180 165
1200
120
600
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
600
Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
99.1%
69
Yes-VDT Intensive Use
$3.48 based on 3000 hrs.
and $0.08 per KWH
60
1200
0
0.0
15
30
Horiz 0-180
90.0
45.0
Page 3/4 Rev. 06/30/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
45
Test Date 9/13/02
Curves / CV PERF
Cûrv Perforated
1, 2, 3-Lamp T5, T5HO or 1, 2, 3, 4-Lamp T8, Indirect Distribution
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-1T5HO-PERF-EP-HRF
Cûrv Architectural Curve
9.5" × 48" 1-Lamp
with Perforated Highly
Specular Reflector
QT1X54/120PHO
1.00
F54T5
4400
61
Pendant
0º = 90 90º = 90
0º = 1.46 90º = 1.53
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
28
32
24
26
29
32
37
22
27
36
53
106
28
32
24
26
29
32
37
22
27
36
53
106
28
32
36
39
43
32
37
44
54
36
53
106
28
32
36
39
43
38
37
44
54
71
53
106
28
32
36
39
43
32
37
44
54
71
53
106
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
3
4
8
13
1965
2761
3818
4351
4364
0.1
0.1
0.2
0.3
44.7
62.8
86.8
98.9
99.2
0.1
0.1
0.2
0.3
45.0
63.3
87.5
99.7
100.0
RCR
Luminaire
Angle
Luminaire Data Test 12987
RC
RW
1
2
3
4
5
6
7
8
9
10
70
86
78
71
65
59
54
50
46
43
40
80
50 30
82 78
72 66
63 56
55 48
49 42
43 36
39 32
35 28
32 25
29 22
10
75
61
51
43
36
31
27
23
20
18
70
73
67
61
55
50
46
43
39
36
34
70
50 30
70 67
61 57
54 48
47 42
42 36
37 31
33 27
30 24
27 21
25 19
10
65
53
44
37
31
27
23
20
18
15
50
48
42
37
33
29
26
23
21
19
17
50
30
46
39
34
29
25
22
19
17
15
13
10
45
37
31
26
22
19
16
14
12
11
Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0
180 165
1700
150
135
120
850
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
850
Energy Data
60
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
99.2%
72
Yes-VDT Intensive Use
$3.33 based on 3000 hrs.
and $0.08 per KWH
1700
0
0.0
15
30
Horiz 0-180
90.0
45.0
45
Test Date 12/18/01
Photometric Data
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous
Opening in Feet
CV-2T5HO-PERF-EP-HRF
Cûrv Architectural Curve
9.5" × 48" 2-Lamp
with Perforated Highly
Specular Reflector
QT2X54/120PHO
1.00
F54T5
4400
121
Pendant
0º = 90 90º = 90
0º = 1.33 90º = 1.23
Length: 3.54
Width: 0.33
Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
0
30
40
45
50
55
60
65
70
75
80
85
0.0 22.5 45.0 67.5 90.0
64
64
60
65
72
64
55
44
54
71
53
106
64
53
60
65
57
48
55
65
54
71
106
106
64
64
60
65
72
80
92
87
81
71
106
211
64
64
72
78
86
80
92
87
108
107
106
211
64
64
72
78
86
80
92
109
108
107
159
211
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
6
9
17
26
3241
4994
7407
8584
8610
0.1
0.1
0.2
0.3
36.8
56.7
84.2
97.5
97.8
0.1
0.1
0.2
0.3
37.6
58.0
86.0
99.7
100.0
RCR
Luminaire
Angle
Luminaire Data Test 12933
RC
RW
1
2
3
4
5
6
7
8
9
10
70
85
77
70
64
59
54
49
45
42
39
80
50 30
81 77
71 65
62 55
54 47
48 41
43 36
38 31
34 27
31 24
28 22
10
74
61
50
42
36
30
26
23
20
17
70
72
66
60
54
50
46
42
39
36
33
70
50 30
69 66
60 56
53 48
47 41
41 35
37 31
33 27
30 24
27 21
24 19
10
64
52
44
37
31
26
23
20
17
15
50
47
41
36
32
29
25
23
21
19
17
50
30
46
39
33
29
25
22
19
17
15
13
10
44
37
31
26
22
19
16
14
12
11
Indoor Candela Plot
0
0
0
0
0
0
0
0
0
0
0
0
180 165
3200
150
120
1600
105
90
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
1600
Energy Data
Total Luminaire Efficiency
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
135
60
97.8%
71
Yes-VDT Intensive Use
$3.38 based on 3000 hrs.
and $0.08 per KWH
3200
0
0.0
15
30
Horiz 0-180
90.0
45.0
Page 4/4 Rev. 06/30/13
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
45
Test Date 8/31/01