Operating Instructions Single-phase Digital digital active energy meter with measurement I - U - P - Hz - PF imported and exported energies and by IR side set up communication - Direct connection 32 A IIST106-01 Stand 15-06-2012 Code AD1-32MC Description single-phase active energy-meter with direct connection 0.020 to 32 A 1 tariff - 1 S0 (MID calibrated) Dimension WARNING The Autometers range of DIN rail mounted meters should only been installed by a competent and qualified electrician who is fully aware of the latest electricity regulations concerning the installation of Electricity meters. The AD1-32 must be installed in a suitable enclosure. 1) Quantities displayed • By pushing the “Command button ➀” it is possible to show: Ref. Quantities Unit E1 Active Energy Imported kWh E2 Active Energy Exported kWh Wiring diagram Symbol N N 1 2 L1 L L1 LOAD ➀ MAINS kWh S0 Pulse Output 5-230 V AC 5-300 V DC 2) LCD display pages • The main page is shown at the meter power on, and whenever “Command button ➀” is not pushed for 20 seconds. This page automatically displays the energy counter (E1 or E2) which is increasing at that moment; on the top line is displayed the direction of the energy imported () or exported (). • By pushing the “Command button ➀” is possible to show: 1 x 32 N 230 V AC AD1-32MC MID calibrated - Active energy imported () - Active energy exported () - The Firmware release - The Firmware checksum - The display test page AD1-32MC A C -32M AD1 A ➔ 䉴 Energy exported () imported () ➔ ➔ 䉴 Power 䉴 Energy factor between -1.00 and +1.00 active power in Watt (imported ) 䉴 Firmware Lateral IR checksum ➔ ➔ 䉴 Firmware 䉴 Voltage RMS Lateral IR interfaces ➔ ➔ 䉴 Istantaneous A) Device code and certification data indications 䉴 Frequency release ➔ Sealable terminal covers 䉴 Current RMS ➔ 3) Display View • Liquid crystal display ➂ ➁ 1) kWh display and other parameters 2) Power import/energy () 3) Power export/energy () ➀ Symbols • Measuring elements Cable stripping length and max. terminal screw torque 32 A direct connection main terminals Screw driver PZ1 1.0 Nm 15.5 • Reversal preventing device • Protected by double insulation Tariff and communication terminals Screw driver blade 0.8x3.5 mm 0.8 Nm 9 Technical data Data in compliance with EN 50470-1, EN 50470-3 and EN 62053-31 General characteristics • Housing • Mounting • Depth Operating features • Connectivity • Storage of energy values and configuration Supply • Rated control supply voltage Un • Operating range voltage • Rated frequency fn • Rated power dissipation (max.) Pv Overload capability • Voltage Un • Current Imax Display (readouts) • Display type AD1-32MC direct connection 32 A DIN 43880 EN 60715 DIN 35 mm mm 1 modules DIN rail 70 to single-phase network FRAM memory n° wires - 2 yes VAC VAC Hz VA (W) 230 184 ... 276 50 ±2% ⭐8 (0.6) continuous momentary (1 s) continuous momentary (10 ms) VAC VAC A A 276 300 32 960 LCD digit dimensions n° digits mm x mm kWh s 7 (2 decimals) 6.00 x 3 0.00 ... 999999.9 1 T1 1 class B VAC A A A Hz mA direct 184 ... 276 5 0.25 0.02 ... 32 50 ±2% alternating 20 imp/kWh ms VAC (DC) mA µA yes 1000 90 ms 5 ... 230 ±5% (5 ... 300) 90 1 imp/kWh 5000 VAC kV 1.2/50 µs-kV class class yes 2 300 4 6 II V0 - yes POZIDRIV mm mm2 mm2 mm2 mm2 PZ1 PZ0 16 16 0.15 (4) 0.15 (2.5) °C °C % mm - M1 E2 -25 ... +55 -25 ... +70 ⭐80 ±0.075 IP51(*)/IP20 • Active energy: 1 display, 7-digit • Instantaneous tariff measurement 1 display, 1-digit • Display period refresh Measuring accuracy at 23 ±1°C, referred to nominal values • Active energy and power acc.to EN 50470-3 Measuring input • Type of connection phase/N • Operating range voltage phase/N • Current Iref • Current Imin • Operating range current (Ist ... Imax) direct connection • Frequency • Input waveform • Starting current for energy measurement (Ist) Pulse output S0 acc.to EN 62053-31 • Pulse output for active energy • Pulse quantity • Pulse duration • Required voltage min. (max.) • Permissible current pulse ON (max. 230 V AC/DC) • Permissible current Impuls OFF (leakage cur. max. 230 V AC/DC) Optical interface • Front side (accuracy control) LED Safety acc. to EN 50470-1 • Indoor meter • Degree of pollution • Operational voltage • AC voltage test (EN 50470-3, 7.2) • Impulse voltage test • Protection class (EN 50470) • Housing material flame resistance UL 94 Lateral IR interfaces • For communication moduls connection (LAN-TCP/IP / M-Bus / Modbus RTU / KNX / SD-Card Datalogger) Connection terminals • Type cage main current paths screw head Z +/• Type cage pulse output blade for slotted screw • Terminal capacity main current paths solid wire min. (max.) stranded wire with sleeve min. (max.) • Terminal capacity pulse outlet solid wire min. (max.) stranded wire with sleeve min. (max.) Environmental conditions • Mechanical environment • Electromagnetic environment • Operating temperature • Limit temperature of transportation and storage • Relative humidity (not condensation) • Vibrations 50 Hz sinusoidal vibration amplitude • Degree protection housing when mounted in front (terminal) (*) For the installation in a cabinet at least with IP51 protection.