Welcome to the World of Panels GE’s SIX CORE BUSINESSES Infrastructure Commercial Finance Industrial GE Healthcare NBC Universal GE Money GE Industrial – Consumer & Industrial Consumer Products Appliances Lighting Industrial Products Power Quality Multilin Equipment Component g GE Consumer and Industrial EQ 2250 Panels Designed for application like Building, Process Industry, Telecom and Infrastructure markets 2250 LV Panels of GE has been in the market for more than 2 decades Serving in harsh and severe environments.They have not only been type tested but also time tested as well in many installations like Power Station, Process Industries, Buildings,IT Parks, Health facilities and many more NOW AVAILABLE FROM LICENSE PANEL BUILDER g GE Consumer and Industrial Motor Control Centres Bolted Design panels MCC Single Front Fixed and Draw Out Type Power Control Centres Double Front Fixed and Draw Out Type PCC Single Tier PBS-32 PBS-25 MBS-01 MBD-02 PBS-16 MBD-03 Conforms to IS8623 & IEC439 Double Tier PBT-10 Adapter/ Relay Panels g • PCC MCC GE Consumer and Industrial g GE Consumer and Industrial • LT Panel consists of……. – Mechanical Assembly • Bare Panel Assembly • Bus Bar Assembly • Module Assembly with Components • Power Contacts Arrangement – Electrical Assembly • Electrical Wiring and Internal Routine Testing as per IS 8623 g GE Consumer and Industrial GE Power Controls in India…... State-of-the-art facility for manufacturing at E-City , Bangalore….. Built with global Environment, Health & Safety standards of GE Facility includes CNC machines from Amada, Japan And one of the most modern, computercontrolled , vertical storage system… NC for shearing… g GE Consumer and Industrial Basic shell Construction •Die Cast Tripod(A Unique Design Concept) •Gusset plate •Fastening by high Torque pneumatic tool Highly rigid construction g GE Consumer and Industrial PCCs & MCCs Bolted design of panels for Total flexibility for site modification Totally weld free g GE Consumer and Industrial PCCs & MCCs Bolted design of panels for Total flexibility for site modification g GE Consumer and Industrial • LT Panel consists of……. – Mechanical Assembly • Bare Panel Assembly • Bus Bar Assembly • Module Assembly with Components • Power Contacts Arrangement – Electrical Assembly • Electrical Wiring and Internal Routine Testing as per IS 8623 g GE Consumer and Industrial Typical arrangement of bus Power Control Centres Type of panels PBS32 PBS25 PBS16 Panel PBS32 PBS25 PBS16 Suitable Breakers 3200A & 4000A 2000A & 2500A 800A to 1600A W (mm) D (mm 1000 1500 800 1300/1500 600 1000 Top and Bottom Cable/ Bus Duct Entry Design g GE Consumer and Industrial Bus Bar Sizing for Horizontal and Vertical Bus Bars Sr. No 1 2 3 4 5 6 7 8 9 10 RATING 600A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A 5000A H- BUS SIZE(mm)FOR 2250 Panel Aluminium ( in MM) Copper ( in MM) 60x10 80x10 100x10 120x10 2(100X10) 2(120X10) 2X2(100X10) 2X2(120X10) 2X2(6"X1/2") 2X2(8"X1/2") 50x10 60x10 80x10 100x10 120x10 2x100x10 2x120x10 3x120x10 3x160x10 V- BUS SIZE(mm)FOR 2250 Panel 1 1A 600A 600A 50x12 60x10 50x12 60x10 g GE Consumer and Industrial Validated Design by CPRI Construction • Aluminium and Copper Bus Bar Design • Bus Bars are PVC Insulated. • Horizontal as well as Vertical bus bars supported by DMC/ SMC insulators • FRP barrier between vertical Bus Bars(Opt) • Bus Bar Short Circuit Rating Tested Up to 65KA for 1 Second •Copper control Bus Bars are located at the top chamber from Front. • Vertical Bus Bars fully shrouded • Shrouded Tap-off points • All Bus Bar joints are shrouded with Nut Caps with Extended Bus Bar Sleeving. Panel type Width(mm) Depth (mm) Single Front 800 600 Double Front 800 1000 g GE Consumer and Industrial • LT Panel consists of……. – Mechanical Assembly • Bare Panel Assembly • Bus Bar Assembly • Module Assembly with Components • Power Contacts Arrangement – Electrical Assembly • Electrical Wiring and Internal Routine Testing as per IS 8623 g GE Consumer and Industrial Motor Control Centres (Modules) • • • Standard sizes Basic size-125mm in multiples of 125mm- up to 750mm max Maximum of 15 units of 125mm per panel Components can easily be fixed on DIN rail / C channels with special ‘nut’ insert Dimension Nomenclature 125 mm. SE 0.5 250 mm. SE 1.0 375 mm. SE 1.5 500 mm. SE 2.0 625 mm. SE 2.5 750 mm. SE 3.0 250 mm. size SE 1.0 Module g GE Consumer and Industrial Motor Control Centres Modules 1 Moving Control Contacts 2 2 Moving Power Contacts(outgoing) 3 Moving power contacts (Incoming) 3 (behind the module) 4 Cranking screw 1 4 g GE Consumer and Industrial Motor Control Centres (Modules) 1 Fixed Control Contacts 2 Fixed (Panel) Outgoing power contacts mounted in Cable Alley 3 4 5 Fixed (Panel) T Power Contacts Mounted on Vertical Bus Bars 5 3 1 Nut plate for cranking FRP sheets 2 4 g GE Consumer and Industrial Motor Control Centres Features/ CTQs • High Contact pressure for draw out power contacts of silver coated copper • Spacious cable chambers-300mm wide(standard) • Draw out module-Service / test / isolated • Vertical bus bars designed for 4 pole plug-in system • Positive locking of trays after insertion Up to IP54 • No door cut-outs-for high degree of protection • Pad Locking Arrangement at all the three position g GE Consumer and Industrial Motor Control Centres Modules 1 Distinct positions 1 Service 2 Test 3 Isolated 2 3 4 Unique Maintenance Position Available on Request g GE Consumer and Industrial • LT Panel consists of……. – Mechanical Assembly • Bare Panel Assembly • Bus Bar Assembly • Module Assembly with Components • Power Contacts Arrangement – Electrical Assembly • Electrical Wiring and Internal Routine Testing as per IS 8623 g GE Consumer and Industrial Module Contacts:- Module Incoming and Module Outgoing RNSU CONTACTS UPTO 100AMPS RATINGS SU CONTACTS FOR 101- 200AMPS RATINGS g GE Consumer and Industrial Module Contacts:- Module Incoming and Module Outgoing 2XDU CONTACTS FOR 350AMPS AND ABOVE RATINGS DU CONTACTS FOR 201-350 AMPS RATINGS g GE Consumer and Industrial Panel Contacts:- Panel Incoming and Panel Outgoing Panel Incoming “T” Contacts Panel Outgoing Contacts g GE Consumer and Industrial • LT Panel consists of……. – Mechanical Assembly • Bare Panel Assembly • Bus Bar Assembly • Module Assembly with Components • Power Contacts Arrangement – Electrical Assembly • Electrical Wiring and Internal Routine Testing as per IS 8623 g GE Consumer and Industrial Internal Routine Testing as per IS 8623 • • • • • Physical Inspection as per Dimension Drawings Components Verification as per BOQ Functional Verification as per the Schematic Drawings HV Test IR Test g GE Consumer and Industrial • CUSTOMER BASE Power Sectors- Refineries- NTPC IOCL BHEL HPCL KPCL MRL DVC ONGC MSEB CPCL NLC IPCL Tehri Hydro DCL PSEB RRVPNL Ferrous/ Non Ferrous Cement- TISCO Birla Corporation Tata Motors ACC NALCO Dalmia Cement BALCO Bokaro Steel Essar A/c Hy-Grade VSP HCL Bhillai Steel Licensed Panel Builder a mark of Quality…