business center park plaza istanbul hotel michaelangelo south africa Terminal Units Department Export Department Avenue Jean Falconnier B.P. 14 01350 Culoz France Tél : 04 79 42 42 70 Fax : 04 79 42 42 14 Avenue Jean Falconnier B.P. 14 01350 Culoz France Tel : 33 4 79 42 42 20 Fax : 33 4 79 42 42 12 NA 98.59 B RESOLUTELY NEW technocentre renault france Création PHI DESIGN - +33 (0)4 76 65 62 84 - phi@phi-design.com references edf normandie france Innovation DISCOVER ALL THE Technology New FAN COIL UNIT PLUSES CONTROL DEVICES silence ... THE ELECTRONICS ERA 3 levels of standard control devices A modern and avant-garde design, associated with a high level of technology, makes the MAJOR 2 a new concept of non autonomous air conditioning terminal unit. With its white colour (RAL 9010) and reduced dimensions, the MAJOR 2 becomes integrated with all environments. ® PRODUCTS innovation The excellence of communicating systems The V2000 can be connected to the building technical management via the BATIBUS open communication bus. ® The V2000 gives you the best ratio "Comfort/Exploitation Costs", thanks to the optimization of the energy management while holding the desired temperature in each premises. The V2000® is adapted to the evolvement of premises. Very simple to use, it is proposed with various control boxes, with carefully designed ergonomics. optimal safety Profit from all of the benefits of the MAJOR 2 after a simple Water and Electricity connection... The MAJOR 2, either in the vertical cased version or in the horizontal cased version, is proposed in standard, with a choice of three electronic control devices, factory mounted. No more worries for wiring, the installation only requires simple water and electrical connections. O L O N H V 2000 carefully done design ® 60 YEARS experience V 200 COIL The simplified performance A new geometry of high performance fins... The MAJOR 2 is equipped with a high performance, very compact coil, in 2-pipe or 4-pipe versions. Thanks to a hatch, the drain is accessable without dismounting the unit. The electrical battery itself, in 2-pipe/2-wire version, consists of monotube heating elements inserted in the aluminium block : the air flow benefits then from an homogeneous diffusion. Because of its master/slave function, the V200 authorizes the operation of several units within one room, a "comfort/economy" hourly programming and a window contact. simplified maintenance Maximum silence... The MAJOR 2 presents a particularly low acoustic level thanks to the optimization of the fan motor assembly. In fact, the enhancement of the centrifugal impellers' diameter permits a low rotation speed of the motor, leading to a minimum residual noise. With the 7 motor speeds, 3 of them pre-wired in factory, this technology lets you benefit from a silent unit meeting all of your expectations. Just enjoy the comfort given by our very new MAJOR 2. SERVICES in 50 countries V 20 The small basic + and also... ACOUSTICS C E T The MAJOR 2 range offers 3 standard electronic control devices levels : PLUG &PLAY G I E S CIAT innovates with the Major 2 fan coil unit ! EUROPEAN Leader Panel of solutions to meet all the requirements of individual regulations. The accuracy of the temperature adjustment improves the comfort. reduced dimensions high performance coil Engineering data ) (W nts e m o ele NR) ow t po t po ut p ting O or ut(W) tpu outpu utp ut p a o u p e t o ) (IS inp lh g g ou 3 h) ing mm g) rica level ower ool atin heatin t ing m/ c l e c ( o H ( ht (k e h e c l l p i o x w t e e e c b r s i o l g p p l l o i s a i i u f t r x a e n P P o t t r o L W 4Ex Se 2Ai To Ac M ) SAFETY reinforced standard insulation When dismounting the filter for maintenance, a safety catch forbids access to the fan motor assembly. The intake grille is in aluminium, robust, shock resistant. The electrical box and the electronic control devices, mounted, wired and tested in factory, ensure a maximum safety. The electrical heating elements and the temperature limiter inserted in the finned block of the coil guarantee a surface temperature conform to the regulations in force. 426 428 MAINTENANCE 430 432 E U R O V E N T CERTIFIED PERFORMANCE CIAT participates in the certification programmes, always keeping in mind the quality and above board factors, in order to guarantee : the validity of its technical characteristics a common comparison basis on the products through the EUROVENT directory. CIAT associates in the concept of the Live Building, founded on the performances and the inter-operability of the equipments using electrical energy. This procedure fits into the contractor's logic and meets his expectations : comfort, flexibility, conformity, reduction of costs, management and safety. With the V2000® control device, CIAT is present on the European "Intelligent Building" market, by using an evolutive communication protocol : the BatiBUS open bus, recognized by all of our partners specialized in the building trades. Recognized Intelligence CIAT is in conformity with the CE marking, authorizing a free circulation of its units in all of the European Union territory. This marking is a safety and protection token for persons. 434 435 Iconos - Zefa Conformity Intelligent Communication Live building IN FR C AN e The MAJOR 2 has 2 hatches on the upper part, offering direct access to the drain and to the control devices.Two molded notches permit easy handling of the casing, after untightening the two safe fixing screws. The intake grille, on hinges, can be handled in two steps : just rotate the grille toward you up to the safety catch for filter change. Then the access to the motor terminal box, regulation valves, data plate... is done after unhooking this safety catch. The CIAT After-Sales Department assists you and ensures, beyond the 10 years legal period, the follow-up of spare parts. Clearness An easy maintenance ... MADE E W The safety is no longer an option... N kW er ( W) r(k we ) kW r( we ) kW r( we HS 310 1,98 1,43 4,92 3,17 600 39 48 MS 215 1,42 1,02 3,54 2,50 or 29 36 LS 100 0,69 0,49 1,71 1,40 1200 15 29 740x243x575 24 HS 555 3,33 2,42 8,39 4,97 800 41 91 MS 400 2,51 1,80 6,33 4,08 or 32 62 LS 260 1,68 1,20 4,33 3,09 1600 18 36 HS 695 4,60 3,31 11,60 6,92 1200 41 106 MS 490 3,36 2,39 8,52 5,58 or 34 73 LS 275 1,91 1,36 5,06 3,77 2400 17 32 HS 900 6,09 4,31 15,10 5,80 1400 40 134 MS 640 4,50 3,15 11,20 4,72 or 32 87 LS 375 2,67 1,87 6,89 3,29 2800 18 41 940x243x575 28 1140x243x575 36 HS 1085 6,81 4,86 17,40 6,95 2000 41 135 MS 825 5,41 3,82 13,70 5,91 or 34 92 LS 515 3,51 2,46 8,97 4,33 4000 22 46 HS 1330 8,02 5,78 20,70 7,80 2000 47 166 MS 940 6,05 4,29 15,30 6,38 or 38 117 LS 690 4,64 3,27 11,70 5,26 4000 29 94 1340x243x575 42 1540x243x575 50 1540x243x575 50 Cold water temperature : 7/12°C - Summer air temperature : 27°C 50% RH - Hot water temperature : 90/70°C - Winter air temperature : 19°C Comfort levels : 12 dBA acoustic attenuation of room and installation for fan coils 426 to 430 and 14 dBA for fan coils 432 to 435.