21/12/55 Traditional Invivo Diodes solution InVivo 3D Patient Dose Verification System Lin Xu, Medical Physicist IBA Dosimetry, SEACOM Chiangmai 2012 -2- Protect, Enhance, and Save Lives However… Alternative solution: EPID based Invivo solutions Time consuming for the diode device positionning before the treatment Operator dependant Point doses like Dmax or Prescription dose Doesn’t take account of the patient anatomy Protect, Enhance, and Save Lives -3- -4- Protect, Enhance, and Save Lives EPIgray: one solution – two integrated products InVivo Manager (IVM) EPIgray Web-based dashboard (access from anywhere in hospital network) Expert application (dedicated workstation) EPIgray: True workflow efficiency for patient safety Get the Plan Protect, Enhance, and Save Lives -5- Protect, Enhance, and Save Lives CT, RTStruct, RTPlan, RTDose Get the Images EPID images from Linac console or Database EPIgray calculates automatically at import immediate display of results and expert analysis mode reconstructed dose versus reference, at points of interest Get results and alerts at your convenience -6- 1 21/12/55 How it works? The basic physics Clinical Examples: First fraction Analyze patient position with Skin Projection P. François, Ph. Boissard, L. Berger and A. Mazal, «In Vivo Dose Verification From Back Projection Of A Transit Dose Measurement On the Central Axis Of Photon Beams», Paper accepted for publication the 10th of June 2010 at «Physica Medica» -7- Protect, Enhance, and Save Lives Prescribed / Actual Doses to Reference Points Protect, Enhance, and Save Lives Several fraction later: a patient positioning error detected (External movement) EPIGRAY EXPERT SYSTEM: A patient positioning issue? -8- Or errors combine with collimator rotation A combined Patient position issue with forgotten collimator rotation ? EPIGRAY EXPERT SYSTEM: Color coded Alerts Protect, Enhance, and Save Lives -9- Protect, Enhance, and Save Lives Lung Study with CBCT (Internal movements) CT Scanner Clinical results at Institut Curie Cone Beam CT before treatment session Field OAG : Field OAG : Equivalent path: 26,5cm Equivalent path: 31,7cm Depid / Declipse : 0,886 Protect, Enhance, and Save Lives - 10 - Depid / Declipse : 0,983 - 11 - Protect, Enhance, and Save Lives - 12 - 2 21/12/55 EPIGray Benefits Summary Invivo 3D patient absolute dose verification system with EPID transit/exit measurements, no perturbance to the beam. Not only detect the patient dose error but also the patient internal/external movement errors. Easy to use, less setup/calibration time, therapist can handle it. Instant result displaying in seconds instead of long calculation time. Unique InVivo Manager Dicom server for fast data transfer from TPS/R&V Instant email alert Remote access through web browser Result statistics for each LINAC or each tumor locations Protect, Enhance, and Save Lives Thank you - 13 - 3