Knürr CoolAdd®
The universal retrofit solution against
overheating in server racks
Knürr CoolAdd® –
When cold air is no longer enough!
%BUBDFOUFSTBSFTVCKFDUUPDPOTUBOU
changes: new server technologies,
changing IT-requirements and economic pressures mean that modifications
GPSNBOJOFWJUBCMFQBSUPGEBZUPEBZ
life in data centers.
"UUIFTBNFUJNFSBQJEUFDIOPMPHJDBM
BEWBODFTDPNCJOFEXJUIDPOUJOVPVTMZ
rising expectations for data center
technology place existing infrastructures under further pressure. It is not alXBZTQPTTJCMFUPCVJMEGSPNTDSBUDIJO
order to meet these increased de-
mands. In most cases, planning must
CFSFTUSJDUFEXJUIJOUIFDPOGJOFTPGFYJsting structures.
The migration of new servers within
existing data centers places great demands on existing infrastructures. In
most cases, technical limitations are
met and overcome through retrofitUJOH)PXFWFSFWFOJGJUJTQPTTJCMFUP
BEKVTUUIFOFUXPSLJOGSBTUSVDUVSFBOE
FMFDUSJDBMTVQQMZBUSFBTPOBCMFPQFSBting expense, current air conditioning
technology reaches its limitations very
RVJDLMZ0WFSIFBUJOHXJUIJOTVDIJOTUBMMBUJPOTJTUIVTJOFWJUBCMF)PUTQPUT
XJUIJOUIFFOUJSFEBUBDFOUFSJOFWJUBCMZ
lead to the slow-down of data processors until complete shutdown.
$PPM"EE® represents the ideal retrofit
solution for data centers and ITrooms.
It safeguards against the risk of hotspots and helps to avoid overheating of
UIFTFSWFSSBDLT"TQFDJBMGFBUVSFPG
this quick and highly effective solution
is that the existing server rack remains
within the data center. In addition, the
entire wiring may remain as it is, without the need for any alterations!
5IFSFGPSF$PPM"EE® is an easy-to-use
replacement for the server‘s rear door.
It operates on the following technical
principle: safe cooling of the servers‘
emitted air temperature in order to
meet the required supply air temperature.
$PPM"EE®DPOTJTUTPGUISFFCBTJDDPNponents:
- connection adaptor for the existing
server rack
- air-water-heat-exchanger
GJYFEUPUIFSBDL
CBDLEPPSXJUIGBOT
The server’s thermal power loss is
transferred into the data center’s cold
XBUFSJOTUBMMBUJPOCZNFBOTPGUIFBJSXBUFSIFBUFYDIBOHFS1PXFSGVMGBOT
ensure optimum cooling-out.
$POWFOJFOUJOTUBMMBUJPO$PPM"EE® may
CFNPVOUFEPOBMMDVSSFOUMZBWBJMBCMF
server racks. The installation is mounUFEPOUPBOBEBQUPSGSBNF"TBTFcond step, the heat-exchanger is fixed
onto the existing rack. It is recommended that the cold water supply is conOFDUFEUISPVHIUIFCBTF'BOTBSF
positioned at the door in order to
maintain perfect access to the entire
installation within the rack.
$PPM"EE® - the quick and economic solution against hotspots in data centers
and IT-rooms; the immediate aid for
TFDVSJOHCVTJOFTTDSJUJDBMQSPDFTTFT
#VTJOFTT$SJUJDBM$POUJOVJUZŠ
Features
Benefits
… Installation with adapter kit
…"EKVTUNFOUPGKVTUBGFXQBSUT
… Thermostatic shuttle valve for regulating
cooling power
….BOVBMGBOTQFFETFUUJOH
… Individual fan monitoring
… Individual fan protection
… Installation with adapter kit
…4IVUUMFWBMWFGPSSFHVMBUJOHDPPMJOHQPXFS
…)FBUFYDIBOHFSJTGJSNMZDPOOFDUFEXJUIUIF
FYJTUJOHSBDLQJQFTBOEPUIFSDPOOFDUJPOT
BSFOPUBDDFTTJCMFJOUIFEBUBDFOUSF
…3FEVOEBOUOGBOTFUVQ
…$PPM"EE®DBOCFVTFEXJUIBMMDVSSFOUSBDLUZQFT
…4FSWFSSBDLSFNBJOTVODIBOHFE
…4MJNEFTJHOIFBUFYDIBOHFSNN
…"DDFTTUPDPNQPOFOUTJTBMXBZTNBJOUBJOFE
…8BUFSDBSSZJOHDPNQPOFOUTBSFTBGFMZTIJFMEFEGSPNUIFSBDL
…&YJTUJOHSBDLTDBODPOUJOVFUPCFVTFE
…&YJTUJOHDBCMJOHSFNBJOT
… Quick installation
…+VTUBGFX$PPM"EE®DPNQPOFOUTIBWFUPCFBEKVTUFE
… Cools the server’s warm exhaust air side
…"DDFTTUPBMMCVJMUJODPNQPOFOUTBMXBZTNBJOUBJOFE
…3FMJFWFTUIFEBUBDFOUSFµTUIFSNBMNBOBHFNFOUTZTUFN
… Cools an additional 8,000 watts
Cooling
capacity
8 kW
0QUJNBMGBOTJODMVEJOHDBTJOHT
'BOGBJMVSFEJTQMBZ
four speed levels
3PCVTUBOETBGFQUJOUFSMPDL
Width
Height
Depth
Weight
Water
content
Fans
Air-Volume
flow
600 mm
700 mm
800 mm
NN
or NN
160 mm
LH
VQUPLH
1.6 l
'BOT
N3I
4QSFBEDIJMMFEXBUFS
&YIBVTUUFNQFSBUVSFBGUFSIFBUFYDIBOHFS
$POOFDUJPOIFBUFYDIBOHFS
$PPMJOHXBUFSWPMVNFGMPX
1SFTTVSFMPTTIFBUFYDIBOHFS
$
$
²NBMFUISFBE
N3I
NCBS
.BYPQFSBUJOHQSFTTVSFIFBUFYDIBOHFS
.BYBCTPMVUFIVNJEJUZPOTJUF
4UBOEBSEDPMPVST
&MU$POOFDUJPOGBOTGBODPOUSPM
1SPUFDUJPODMBTT
CBS
HLH
3"-CMBDLHSFZ
7)[8
*1
4UBUF
4IPVMEFSFEUIFSNPTUBUSFMBZ
XJUIFYUFOTJCMFDPNQPOFOU
XJUIPVUBVYJMJBSZQPXFS
www.knuerr.com
Knürr CoolAdd® – setting standards
Knürr’s CoolAdd® sets new standards when it comes to cost-effectiveness –
as an ideal upgrade solution for all current server racks in small IT rooms or
large-scale data centers!
Knürr is also a guarantor for system solutions in IT and
network technology with products of an exceptional
level of quality. Innovative rack platforms, proven-inpractice thermal management and tailor-made power
supplies meet the future-proof requirements of the
data center, telecommunications and network
technology.
Adaptive Architecture™ –
The solution for securing
business-critical processes.
Primary
cooling circuit
Secondary
cooling circuit
CoolTrans®
CoolAdd®
&NFSTPO/FUXPSL1PXFSQSPWJEFTJOOPWBUJWFTPMVUJPOTBOEFYQFSUJTF
JOBSFBTTVDIBT"$BOE%$QPXFSTVQQMZQSFDJTJPODPPMJOHTZTUFNT
FNCFEEFEDPNQVUFSBOEQPXFSTVQQMZTZTUFNTJOUFHSBUFESBDLT
and enclosures, network circuits and controls, monitoring and
DPOOFDUJWJUZ"MMTPMVUJPOTBSFTVQQPSUFEMPDBMMZBMMPWFSUIFXPSME
CZ&NFSTPO/FUXPSL1PXFSDVTUPNFSTFSWJDFUFDIOJDJBOT:PVXJMM
¾OENPSFJOGPSNBUJPOPO&NFSTPO/FUXPSL1PXFSµTQSPEVDUTBOE
support services at
Locations
Emerson Network Power - EMEA
7JB-FPOBSEP%B7JODJ
Zona Industriale Tognana
1JPWFEJ4BDDP1%
… Italy
T
F
marketing.emea@emersonnetworkpower.com
www.emersonnetworkpower.com
www.eu.emersonnetworkpower.com
www.emerson.com
www.knuerr.com
Emerson Network Power Racks and Solutions
.BSJBLJSDIFOFS4USB‡F
"SOTUPSG…(FSNBOZ
T
F
info@knuerr.com
Emerson Network Power - USA
%FBSCPSO%SJWF
10#PY
$PMVNCVT0)
T
Emerson Network Power - Asia
'%BI4JOH'JOBODJBM$FOUSF
(MPVDFTUFS3PBE8BODIBJ
)POH,POH
T
F
8IJMFFWFSZQSFDBVUJPOIBTCFFOUBLFOUPFOTVSFBDDVSBDZand completeness in this
MJUFSBUVSF&NFSTPO/FUXPSL1PXFSBTTVNFTOPSFTQPOTJCJMJUZBOEEJTDMBJNTBMMMJBCJMJUZ
for damages resulting from use of this information or for any errors or omissions.
‰&NFSTPO/FUXPSL1PXFS
"MMSJHIUTSFTFSWFEUISPVHIPVUUIFXPSME4QFDJGJDBUJPOTTVCKFDUUPDIBOHFXJUIPVUOPUJDF
Emerson Network PowerTM
The Global leader in Business-Critical Continuity™ solutions.
"$1PXFS
Connectivity
%$1PXFS
&NCFEEFE$PNQVUJOH
&NCFEEFE1PXFS
*OGSBTUSVDUVSF.BOBHFNFOU.POJUPSJOH
0VUTJEF1MBOU
1PXFS4XJUDIJOH$POUSPMT
1SFDJTJPO$PPMJOH
3BDLT*OUFHSBUFE$BCJOFUT
4FSWJDFT
4VSHF1SPUFDUJPO
#VTJOFTT$SJUJDBM$POUJOVJUZ&NFSTPO/FUXPSL1PXFSBOEUIF&NFSTPO/FUXPSL1PXFSMPHPBSFUSBEFNBSLTBOETFSWJDFNBSLTPG&NFSTPO&MFDUSJD$P‰&NFSTPO&MFDUSJD$P
….*…1SJOUFEJO(FSNBOZ…Concept, graphics, editorial: (SPQQ)VCFS…4VCKFDUUPUFDIOJDBMDIBOHFTFSSPSTBOEPNJTTJPOT
&NFSTPO/FUXPSL1PXFSBEJWJTJPOPG&NFSTPO/Z4&&.3
JTUIFXPSMEµTMFBEJOHQSPWJEFSPG#VTJOFTT$SJUJDBM$POUJOVJUZŠ
²(SJEUP$IJQ³TPMVUJPOTGPSUFMFDPNNVOJDBUJPOOFUXPSLTEBUB
centers, medical facilities and industrial systems.
Download