DC Energy - Charger
CE-P chargers are designed to charge
12 V to 48 Vdc / 7 to 150 Ah battery
or maintain larger battery used for
Genset starter.
Benefits
Quick installation in electrical panels
A universal reference (battery or sealed
lead-opened or manual, single or
dual voltage),
n DIN rail mounting (included),
n Plug-in connectors (Easy wiring),
n Built in incoming / outgoing fuses (time/
space savings),
n Fully protected (short circuits - reverse
polarity - coding connectors),
n Complies to NFC 58-311 (Gas emissions
secured).
n
Designed for heavy environments (Genset)
Exceptional input voltage (305 Vac),
Wide temperature operating range,
n Screws fixing (different mountings possible),
n Many safety features built in (reliability),
n Functions improving battery life time,
n Clear signalling (easy maintenance),
n One single product for both 12V and 24V,
or 30V and 48V.
n
n
They can also be integrated on a support plate, in box or in electrical panels
to provide power supplies with backup for process control systems, or to LV/MV
switchgears.
They can be also easily used as a 12, 24, 30 or 48 Vdc power supply.
CE-P
Industrial Power for
Business-Critical Continuity™
DC Energy - Charger
Technical Specification
Reference
6011054
6011060
CE-P 2.5 12
CE-P 08 12
6007024
CE-P 05 12/24
6011062
CE-P 2.5 30/48
Input
187 to
305 VAC
50/60 Hz
Voltages
Output Adjustement
12V
12 to 15 VDC
12V
12 to 15 VDC
12V
12 to 15 VDC
24V
24 to 30 VDC
30V
30 to 38 VDC
48V
48 to 60 VDC
Dualvoltage
No
No
Current
Signalling
Output Status Led Relay 58 311
2.5A
2
No
No
8A
4
Yes
Yes
Yes
5A
4
Yes
Yes
Yes
2.5A
4
Yes
Yes
This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary
any information without prior notice. Crédits Photos : Georges Rivalain, iStockPhoto, Fotolia. CE-P-DSUK-Rev0-07/2012
Code
Functions
Boost
For vented lead and Ni-Cd batteries starting-up and equalizing, it is useful to set the voltage
at a higher level for several hours. The boost device rises the charging voltage by 3.8%.
This function is activated by strapping connector terminals. The voltage automatically returns
to the initial tension after 12 hours in boost (manual return on 6011054).
Battery test
The test allows to prevent back up interruption due to a wire or a battery link cut or defective
battery. The test can be performed automatically or manually from free volt contact control.
Function not available 6011054.
Signalling
The charger status is indicated by a Led
• Charger Ok: Led lighted up
• No input sector fuse and mains fault: LED off
Additionally (not available 6011054): contact signals synthesis fault
• Low battery voltage: Led flashes (quick)
• High charger voltage: Led flashes (quick)
Charger shuts down in case of regulation lost to protect all the connected equipments
• Battery test (on a battery fault): Led flashes (quick)
• Overload or battery discharged (current limit): the LED flashes intermittently; no fault report.
Option
Box integration with or without battery
General data
Input voltage
Static regulation
Output current
Ambient operating/storage temperature
Relative humidity
Isolation
Protection
Weight
Dimension
Standards
Compliance
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
187 to 305 VAC - 47 to 63 Hz
±1% for cumulative parameters
± 5%
-20 to +50°C / - 45 to +85°C
< 95% to 20°C - Cooling: Natural convection
Classe I
IP 20
0.5 kg
155 x 112 x 65 mm
Product: NF C 58-311 / NF EN 61204 (except 6011054)
ECM n°2004/108/CE
NF EN 61000-6-2 / NF EN 61000-6-4
Complies to (LV Safety Compliance) n°2006/95/CE
NF EN 50178 - complies to SELV
Transformers comply to NF EN 61558-2-17
n AC Power
n Connectivity
n DC Power
n Embedded Computing
Emerson Network Power IS SAS
30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex France
T +33 (0) 4 72 47 63 77 - F +33 (0) 4 78 40 13 94
E aees@emerson.com / www.aees.fr
EmersonNetworkPower.com
n Embedded Power
n Industrial Power
n Infrastructure Management & Monitoring
n Outside Plant
n Power Switching & Controls
n Precision Cooling
n Racks & Integrated Cabinets
n Services
Emerson, Business-Critical Continuity and
Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©2011 Emerson Electric Co.
E-0000 000
Download