Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® 2.75 in (70 mm) Product family features Full family of controls plus matching fan controls, switches, and wiring devices • Exclusive dimmer/switch size opening • Slide adjusts light to suit any activity • Classic slider, thin profile design • Voltage compensation maintains stable light levels, despite line voltage variations • 4.56 in (116 mm) Mechanical air-gap to disconnect load power • 100% factory tested • Coordinating wallplate included with Architectural matte finish controls; metal wallplates only available separately • Custom engraving and custom coloring available for wallplates, see pg. 164 • Control types .30 in (7.6 mm) profile Shown actual size: Nova Tb dimmer in Black (BL) with 1-gang Architectural wallplate in Clear Anodized Aluminum (CLA). Single-pole (one location) 3-way or 4-way (two or more locations) Direct load type compatibility Incandescent/halogen lighting Magnetic low-voltage lighting Electronic low-voltage lighting Fluorescent lighting LED lighting Ceiling fans Load types requiring load interface Neon/cold cathode lighting Lighting load interfaces may be applicable for some additional load type, voltage, and capacity combinations. For additional information, see pg. 185. Download specification submittal 25 Volume 1 P/N 367-1746 REV B www.lutron.com/specificationguide | 1.800.523.9466 | Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Available finishes Use BOLD color code in model number (Example: NT-600-SI) Architectural matte finishes* WH White LA Light Almond AL Almond BE Beige GR Gray SI Sienna BR Brown BL Black IV Ivory TP Taupe QZ Antique Bronze Architectural metal finish wallplates** BN Bright Nickel BC CLA SC Bright Chrome Clear Anodized Satin Chrome Aluminum SN Satin Nickel AU Gold Plated BB Bright Brass QB BLA Antique Brass Black Anodized Aluminum BRA SB Brass Anodized Satin Brass Aluminum *Coordinating wallplate included with Architectural matte controls. **Metal finish wallplates only available separately and include black plastic trim/adapter, visible from side. Match with separate Black (BL) controls. For wallplate information, see pg. 161. | 1.800.523.9466 | www.lutron.com/specificationguide Volume 1 P/N 367-1746 REV B 26 Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Electronic low-voltage dimmers* (small controls) Slide-to-off dimmers Slide up to brighten, down to dim • Loads from 1000-2000 Watts require large controls • Slide-to-off dimmers Single-pole 120 V 300 W Single-pole 120 V 600 W NTELV-300-XX1 NTELV-600-XX1 Certain LED drivers are dimmable using an ELV dimmer; for more information visit www.lutron.com/LED. Incandescent/halogen dimmers (small controls) 3-wire fluorescent dimmers* (also for Hi-lume® A-Series LED drivers) (small controls) Slide-to-off dimmers Single-poleNT-600-XX1 120 V 600 W Single-poleNT-1000-XX1 120 V 1000 W Slide-to-off dimmers Magnetic low-voltage dimmers (small controls) For use with EcoSystem®, Hi-lume 3D and Hi‑lume ballasts, and Hi-lume A-Series LED drivers. Slide-to-off dimmers No derating required if ganged. Single-poleNTLV-600-XX1 120 V 600 VA (450 W) Single-poleNTLV-1000-XX1 120 V 1000 VA (800 W) Single-pole*NTLV-600-277-XX1 277 V 600 VA (450 W) Single-pole*NTLV-1000-277-XX1 277 V 1000 VA (800 W) Adjustable low-end trim. For more information on Hi-lume A-Series LED drivers, visit www.lutron.com/HilumeLED. Single-poleNTF-10-XX1 120 V 16 A Single-poleNTF-10-277-XX1 277 V 8 A The stated VA (Volt-Ampere) rating includes the magnetic transformer heat losses and the lamp load. The stated W (Watt) rating is the maximum lamp wattage based on assumed 20% transformer loss. 27 XX1:Architectural matte color codes, see pg. 26 (1-gang wallplate included) Volume 1 P/N 367-1746 REV B All models must be derated if ganged, unless otherwise noted, see pg. 179. *Requires neutral wire connection. www.lutron.com/specificationguide | 1.800.523.9466 | Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® 0-10 V fluorescent dimmer (current sink control) (also for 0-10 V LED drivers) (small control) Slide-to-off dimmers Higher capacity dimmers require larger heat sink behind wallplate • Slide-to-off dimmer Single-poleNTFTV-XX1 30 mA max control current Slide up to brighten, down to dim • Control provides dimming signal only. For dimming with on/off switching, use with Lutron Power Pack: PP-120H, PP-277H, or PP-347H. Measures 4.56 in x 4.56 in • Consult ballast manufacturer for specific ballast current draw to determine maximum number of ballasts per control. Requires large wallplate • Most can fit in a 1-gang electrical backbox • For information on using Lutron dimmers to control Advance Mark 7 dimming ballasts, visit www.lutron.com/advance; Universal dimming ballasts, visit www.lutron.com/universal. No derating required if ganged. For compatible 0-10 V LED drivers by others, visit www.lutron.com/LED. Tu-Wire® fluorescent dimmers (small controls) Slide-to-off dimmers Single-poleNTFTU-5A-XX1 120 V 5 A Single-pole*NTFTU-5A-277-XX1 277 V 5 A Also compatible with Advance Mark 10 ballasts, for further information visit www.lutron.com/advance. For information on use with Universal and OSRAM ballasts, contact Technical Support at 1.800.523.9466; Universal dimming ballasts visit www.lutron.com/universal. XX1:Architectural matte color codes, see pg. 26 (1-gang wallplate included) Incandescent/halogen dimmers (large controls) Slide-to-off dimmers Single-poleNT-1500-XX1 120 V 1500 W Single-poleNT-2000-XX1 120 V 1920 W NT-2000 dimmers must be ganged with no fins broken. See ganging and derating on pg. 179 for further information. NT-2000 requires a 2-gang electrical backbox. Magnetic low-voltage dimmers (large controls) Slide-to-off dimmers Single-poleNTLV-1500-XX1 1500 VA (1200 W) The stated VA (Volt-Ampere) rating includes the magnetic transformer heat losses and the lamp load. The stated W (Watt) rating is the maximum lamp wattage based on assumed 20% transformer loss. All models must be derated if ganged, unless otherwise noted, see pg. 179. *Requires neutral wire connection. | 1.800.523.9466 | www.lutron.com/specificationguide Volume 1 P/N 367-1746 REV B 28 Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Preset dimmers Button turns on/off to slider level • Slide up to brighten, down to dim • Loads from 1000-1500 watts require large controls • Incandescent/halogen dimmers (small controls) 3-wire fluorescent dimmers* (also for Hi-lume® A-Series LED drivers) (small controls) Preset dimmers 3-wayNTF-103P-XX1 120 V 8A 3-wayNTF-103P-277-XX1 277 V 6A For use with EcoSystem®, Hi-lume 3D and Hi‑lume ballasts, and Hi-lume A-Series LED drivers. No derating required if ganged. Adjustable low-end trim. Preset dimmers 3-way/single-poleNT-603P-XX1 120 V 600 W 3-way/single-poleNT-1003P-XX1 120 V 1000 W For more information on Hi-lume A-Series LED drivers, visit www.lutron.com/HilumeLED. To control lights from multiple-locations, use 3-way dimmer with NT-3PS- and NT-4PS- or other mechanical switches. Magnetic low-voltage dimmers (small controls) Preset dimmers 3-way/single-pole (small) 120 V 600 VA (450 W) 3-way/single-pole (small) 120 V 1000 VA (800 W) NTLV-603P-XX1 NTLV-1003P-XX1 The stated VA (Volt-Ampere) rating includes the magnetic transformer heat losses and the lamp load. The stated W (Watt) rating is the maximum lamp wattage based on assumed 20% transformer loss. 29 XX1:Architectural matte color codes, see pg. 26 (1-gang wallplate included) Volume 1 P/N 367-1746 REV B All models must be derated if ganged, unless otherwise noted, see pg. 179. *Requires neutral wire connection. www.lutron.com/specificationguide | 1.800.523.9466 | Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Preset dimmers Linear-slide switches Slide up to on, down to off Higher capacity dimmers require larger heat sink behind wallplate • • Works with all load types • Button turns on/off to slider level • Slide up to brighten, down to dim • Measures 4.56 in x 4.56 in • Requires large wallplate • Most can fit in a 1-gang electrical backbox • Incandescent/halogen dimmers (large controls) Preset dimmers 3-way/single-poleNT-1503P-XX1 120 V 1500 W Switches (small controls) General purpose switches—all load types Single-poleNT-1PS-XX1 120/277 V 20 A 3-wayNT-3PS-XX1 120/277 V 20 A 4-wayNT-4PS-XX1 120/277 V 20 A For 3-way and 4-way switching, use NT-3PS-, NT-4PS- or other mechanical switches. No derating required if ganged. Magnetic low-voltage dimmers (large controls) Preset dimmers 3-way/single-poleNTLV-1503P-XX1 120 V 1500 VA (1200 W) The stated VA (Volt-Ampere) rating includes the magnetic transformer heat losses and the lamp load. The stated W (Watt) rating is the maximum lamp wattage based on assumed 20% transformer loss. XX1:Architectural matte color codes, see pg.26 (1-gang wallplate included) All models must be derated if ganged, unless otherwise noted, see pg. 179. | 1.800.523.9466 | www.lutron.com/specificationguide Volume 1 P/N 367-1746 REV B 30 Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Slide-to-off fan controls Slide-to-off fan controls Slide up to increase speed/ on; down to decrease speed/off Slide up to increase speed/on, down to decrease speed/off • • Quiet 3-speed model designed to prevent motor hum (for use with one paddle fan) Fully variable for use with multiple paddle or exhaust fans • • Higher capacity controls require larger heat sink behind wallplate • Fully variable for use with multiple paddle or exhaust fans • Measures 4.56 in x 4.56 in Higher capacity loads require large controls • • Requires large wallplate • Most can fit in a 1-gang electrical backbox • Fan controls (small controls) Slide-to-off fan control—quiet 3-speed Single-pole fan control 120 V 1.5 A NTFSQ-XX1 For use with only one ceiling fan. No derating required if ganged. Slide-to-off fan controls—fully variable Slide-to-off fan controls—fully variable Single-pole fan control 120 V 6 A 31 Single-pole fan control 120 V 12 A NTFS-12E-XX1 NTFS-6E-XX1 XX1:Architectural matte color codes, see pg. 26 (1-gang wallplate included) Volume 1 P/N 367-1746 REV B Fan controls (large controls) All models must be derated if ganged, unless otherwise noted, see pg. 179. *Requires neutral wire connection. www.lutron.com/specificationguide | 1.800.523.9466 | Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Connections overview Load connections* Magnetic Low-Voltage Incandescent/ Halogen MLV Transformer (by others) Incandescent/ Halogen Dimmer Electronic Low-Voltage ELV Transformer (by others) MLV Dimmer LED Fluorescent Lutron Dimming Ballasts ELV Dimmer Switched Ceiling Lighting/Fans Fan Lutron Hi-lume ® A-Series LED Driver Fluorescent Dimmer Fluorescent Dimmer (3-wire only) Switch Fan Control Dim from one location, switch from the others Light Source 3-way Dimmer Light Source 3-way Dimmer 3-way Switch 4-way Switch (1 or more) 3-way Switch Download complete Connection Diagrams For more information on ballasts, visit www.lutron.com/ballasts. For more information on LED drivers, visit www.lutron.com/LED. *For illustration purposes only. Consult model number pages for specific voltage and capacity information. | 1.800.523.9466 | www.lutron.com/specificationguide Volume 1 P/N 367-1746 REV B 32 Architectural wallplate opening Nova Tb dimmers, switches, and fan controls ® Accessories Wallplates 4.56 in (116 mm) Shown actual size: 2-gang Architectural wallplate in White (WH). For more information about Architectural wallplates, see pg. 161. 4.56 in (116 mm) .30 in (7.6 mm) profile Coordinated electrical devices For more information about coordinated Architectural electrical devices, see pg. 165. Tamper resistant GFCI receptacle 33 Customizable 6-port frame Volume 1 P/N 367-1746 REV B Cable jack www.lutron.com/specificationguide | 1.800.523.9466 |