ZipWaveTM | LED | 707 Install Guide

advertisement
ZipWaveTM | LED | 707
Install Guide
Please read instructions in their entirety before proceeding with any part of the installation. This luminaire
must be installed in accordance with the National Electric Code and local regulations. This luminaire must
be installed by a qualified electrician. Use of ballast or other components not supplied by Vode Lighting voids
warranty. To prevent electric shock, turn off electricity at the fuse box before proceeding. Do not install this
product in wet locations. UL listed for dry and damp locations only. Retain instructions for future reference.
Technical Support: 707-996-9898
IMPORTANT! Before installing power supply turn off electricity at circuit box and consult wiring diagram.
Armstrong Ceiling Cove: AC
NOTE: Install Vode ZipWave lighting fixtures only after the AXIOM® Indirect Ceiling-to-Ceiling Light cove is installed.
1. Starting with the fixture farthest from the j-box, place fixture into the Armstrong AXIOM® Indirect Ceiling-to-Ceiling Light Cove so it
is securely positioned on the key way. The key way ensures the lighting fixture is positioned correctly inside the cove.
2. Place the second fixture next to the first fixture and connect the cable assembly. Push the fixtures together so they touch. Continue
this process until you reach the end of the fixture run.
3. Make note of the fixture connector type (male or female) and use the appropriate Vode wire harness to connect to the power supply.
The Vode wire harness comes with a removable end cap. The end cap should be placed on the cable assembly at the far end of the run.
connect fixture to
Vode wire harness
(provided)
Installed View
Ceiling
Key Way
Ceiling
Connect fixture cable
assemblies
Optional
To connect two fixture runs to the same power supply, use the male to female jumper cable (ex. for corner or parallel runs).
Jumper Cable
Jumper Cable
© Copyright 2015. All ideas, arrangements, and plans indicated or represented by the above drawings, are the property of Vode Lighting LLC. and were created, evolved and
developed for use on and in concoction with the specified project. No part of the above drawing, design, arrangements or ideas thereon shall be duplicated or used for any purpose
whatsoever without the express permission of Vode Lighting LLC.
11/2015
ZipWaveTM | LED | 707
Install Guide
Please read instructions in their entirety before proceeding with any part of the installation. This luminaire
must be installed in accordance with the National Electric Code and local regulations. This luminaire must
be installed by a qualified electrician. Use of ballast or other components not supplied by Vode Lighting voids
warranty. To prevent electric shock, turn off electricity at the fuse box before proceeding. Do not install this
product in wet locations. UL listed for dry and damp locations only. Retain instructions for future reference.
Technical Support: 707-996-9898
IMPORTANT! Before installing power supply turn off electricity at circuit box and consult wiring diagram.
Armstrong Wall Cove: AW
NOTE: Install Vode ZipWave lighting fixtures only after the AXIOM® Indirect Ceiling-to-Wall Light cove is installed.
1. Starting with the fixture farthest from the j-box, place fixture into the Armstrong AXIOM® Indirect Ceiling-to-Wall Light Cove so it is
securely positioned on the key way. The key way ensures the lighting fixture is positioned correctly inside the cove.
2. Place the second fixture next to the first fixture and connect the cable assembly. Push the fixtures together so they touch. Continue
this process until you reach the end of the fixture run.
3. Make note of the fixture connector type (male or female) and use the appropriate Vode wire harness to connect to the power supply.
The Vode wire harness comes with a removable end cap. The end cap should be placed on the cable assembly at the far end of the run.
connect fixture to
Vode wire harness
(provided)
Installed View
Key Way
Ceiling
Connect fixture cable
assemblies
Optional
To connect two fixture runs to the same power supply, use the male to female jumper cable (ex. for corner or parallel runs).
Jumper Cable
Jumper Cable
© Copyright 2015. All ideas, arrangements, and plans indicated or represented by the above drawings, are the property of Vode Lighting LLC. and were created, evolved and
developed for use on and in concoction with the specified project. No part of the above drawing, design, arrangements or ideas thereon shall be duplicated or used for any purpose
whatsoever without the express permission of Vode Lighting LLC.
11/2015
ZipWaveTM | LED | 707
Install Guide
Please read instructions in their entirety before proceeding with any part of the installation. This luminaire
must be installed in accordance with the National Electric Code and local regulations. This luminaire must
be installed by a qualified electrician. Use of ballast or other components not supplied by Vode Lighting voids
warranty. To prevent electric shock, turn off electricity at the fuse box before proceeding. Do not install this
product in wet locations. UL listed for dry and damp locations only. Retain instructions for future reference.
Technical Support: 707-996-9898
Wiring for Dimming
Fixtures utilize a five (5) wire cable assembly to allow for easy dimming control. Please consult the wiring diagram below for more
detail.
Dimming via 0-10v
L
N
G
10+
10-
Dimming via DALI
L
N
G
DA
DA
Dimming via HiLume
L
N
G
DL
NC
Dimming via EcoSystem
L
N
G
E1
E2
© Copyright 2015. All ideas, arrangements, and plans indicated or represented by the above drawings, are the property of Vode Lighting LLC. and were created, evolved and
developed for use on and in concoction with the specified project. No part of the above drawing, design, arrangements or ideas thereon shall be duplicated or used for any purpose
whatsoever without the express permission of Vode Lighting LLC.
11/2015
Related documents