LED Architectural Luminaire - Precision

advertisement
RSR
LED Architectural Luminaire
Product Information
Project Name
Type
Catalog Number
Date
SPECIFICATIONS
Features
• The RSR brings cutting edge solid state technology into an architecturally styled luminaire.
• Perfect for relight, retrofit or new construction, RSR delivers a
powerful combination of performance and energy savings.
• Most configurations produce low watts per square footage to
meet the most restrictive lighting power density codes.
• Lens design and materials provide uniform appearance without pixilation.
• Long-life, LEDs at L90 (90% lumen maintenance) at 50,000
hours to reduce life cycle maintenance costs.
• Optional emergency battery backup for safety lighting.
• Available in 2' and 4' lengths.
• Up to 101 lumens per watt.
• Color Rendering Index (CRI) > 80.
Construction
• Fixture housing is die-formed code-gauged steel
• Optical system hinges and latches from either side for easy
access to LED module and electrical components
• Certain airborne contaminants can diminish integrity of acrylic.
Contact factory for chemical compatibility.
• Two shielding design options available
• Weight: 2x2 - 7 lbs. 2x4 - 10 lbs.
Certifications
•
•
•
•
•
•
CSA listed for Canada and U.S. Tested to UL 1598 & UL 8750 standards.
Luminaires bear appropriate listing labels.
Emergency-equipped fixtures labeled UL 924.
Adheres to LM79, LM80 and TM21 industry standards.
DesignLights Consortium® (DLC) qualified.
Please refer to the DLC website for specific product qualifications
at www.designlights.org.
• Please refer to the Lighting Facts website for specific product qualifications
at www.lightingfacts.com.
Electrical
•
•
•
•
•
•
•
•
•
Input Voltage Range: 120-277 VAC Nom.
Frequency: 50/60 Hz Nom.
Active Power Factor Correction
Power Factor: >0.90 @ full load, 120V through 277V
Harmonic Distortion: THD < 20% @ full load
Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit
Compliant to FCC Part 15 requirements for EMI/RFI emissions
NEC/CEC compliant ballast disconnect is standard.
Optional emergency battery pack
Application
• Suitable for use with most wired or wireless lighting control systems
• Suitable for dry & damp locations:
• Government buildings
• Retail
• Commercial areas
• Healthcare facilities
• Educational facilities
Warranty
• Five-year warranty. (Terms and Conditions Apply)
CERTIFICATION
ORDERING INFORMATION
RSR
MODEL
RSR LED
Architectural
Luminaire
SIZE
22 2×2 Nominal
24 2x4 Nominal
EXAMPLE RSR24-35MLG-C-EU
–
–
COLOR
TEMP
CEILING
TYPE
30 3000K
35 3500K
40 4000K
G Grid1
SM Surface
Mount
LUMEN
OUTPUT
LW
ML
HL
VL
Low
Medium
High
Very High
FOOTNOTES
1. For hard ceilings use flange kit accessory (order separately).
2. Bi-Level driver must be controlled by sensor or A/B switching.
3. Must be used in conjunction with lighting controls.
4. Not available with surface mount.
–
SHIELDING
C Contour
R Rail
–
U
DRIVER
OUTPUT
E Fixed
ESD Bi-Level2
ED 0-10V
Dimming3
DRIVER
VOLTAGE
U Universal
120/277 VAC
OTHER
ELL14 Emergency
Battery Pack4
C388 3-Wire Flex,
6',18 Ga
C488 4-Wire Flex,
6',18 Ga
C588 5-Wire Flex,
6',18 Ga
ACCESSORIES
(ORDER SEPARATELY)
FK22 2'x 2' Single Flange Kit
FK24 2'× 4' Single Flange Kit
Page 1/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RSR
LED Architectural Luminaire
PHOTOMETRIC DATA
PHOTOMETRIC DATA: RSR22-35MLG-C-EU
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
ZONAL LUMEN SUMMARY
AVG. LUMINANCE (Candela/Sq. M.)
RSR22-35MLG-C-EU
LED Architectural Luminaire
D255CQ42UNVA-A
1.00
LED
3237
35
Recessed
0º = 90 90º = 90
0º = 1.24 90º = 1.57
Length: 1.80
Width: 1.82
Height: 0.00
Average Luminance Angle
Luminaire
Test: ITL78354
Test Date: 08/15/13
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
Zone
Lumens
%Lamp
%Fixt
3394
3274
3135
3016
2847
2635
2392
2146
1893
1600
1268
829
3394
3646
3547
3397
3179
2927
2668
2395
2113
1828
1495
1018
3394
4405
4251
3982
3660
3340
3036
2760
2469
2184
1854
1169
3394
4716
4298
4001
3691
3386
3082
2791
2507
2196
1816
1056
3394
4761
4323
4024
3701
3374
3069
2776
2469
2196
1684
867
0-30
0-40
0-60
0-90
944
1585
2698
3237
29
49
83
100.0
29
49
83
100.0
INDOOR CANDELA PLOT
90
75
COEFFICIENTS OF UTILIZATION (%)
RCR
RC
RW
1
2
3
4
5
6
7
8
9
10
80
70
110
100
92
84
77
71
66
62
58
54
50
105
92
81
72
65
58
53
48
44
41
70
30
101
86
74
64
56
50
44
40
36
33
10
97
80
67
57
50
43
38
34
31
28
70
107
97
89
82
75
70
65
60
56
53
50
103
90
80
71
64
57
52
48
44
40
50
30
99
84
73
63
55
49
44
40
36
33
10
96
79
67
57
49
43
38
34
31
28
50
99
87
77
69
62
56
51
46
43
39
30
96
82
71
62
54
48
43
39
35
32
0
10
93
78
66
56
49
43
38
34
31
28
0
85
72
61
53
46
40
35
32
28
26
700
60
1400
0
15
30
Horiz 0-180
45
0.0 _____ 45.0 _ _ _ _ 90.0 _ _ _ _
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
PHOTOMETRIC DATA
PHOTOMETRIC DATA: RSR24-35MLG-C-EU
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
ZONAL LUMEN SUMMARY
AVG. LUMINANCE (Candela/Sq. M.)
RSR24-35MLG-C-EU
LED Architectural Luminaire
D310CQ50UNVA-A
1.00
LED
5086
52
Recessed
0º = 90 90º = 90
0º = 1.26 90º = 1.57
Length: 3.81
Width: 1.82
Height: 0.00
Average Luminance Angle
Luminaire
Test: ITL78374
Test Date: 08/21/13
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
Zone
Lumens
%Lamp
%Fixt
2440
2389
2338
2285
2195
2062
1897
1715
1548
1349
1135
855
2440
2676
2687
2617
2492
2322
2136
1943
1747
1553
1359
1176
2440
3212
3147
2979
2768
2541
2325
2127
1929
1745
1564
1158
2440
3391
3149
2931
2695
2449
2217
2013
1811
1613
1377
855
2440
3413
3125
2904
2652
2398
2167
1939
1738
1559
1225
712
0-30
0-40
0-60
0-90
1438
2432
4198
5086
28
48
83
100
28
48
83
100
INDOOR CANDELA PLOT
90
75
COEFFICIENTS OF UTILIZATION (%)
RCR
RC
RW
1
2
3
4
5
6
7
8
9
10
80
70
109
100
91
84
77
71
66
61
57
54
50
105
92
81
72
64
58
52
48
44
40
70
30
101
85
73
63
55
49
44
39
36
33
10
97
80
67
57
49
43
38
34
30
27
70
107
97
89
81
75
69
64
60
56
52
50
103
90
79
71
63
57
52
47
43
40
50
30
99
84
72
63
55
49
43
39
35
32
10
95
79
66
56
49
43
38
33
30
27
50
98
86
76
68
61
55
50
46
42
39
30
95
81
70
61
54
48
43
38
35
32
0
10
92
77
65
56
48
42
37
33
30
27
0
85
71
61
52
45
39
35
31
28
25
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
1000
60
2000
0
15
30
Horiz 0-180
45
0.0 _____ 45.0 _ _ _ _ 90.0 _ _ _ _
Page 2/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RSR
LED Architectural Luminaire
LUMEN PACKAGE OPTIONS
3000K DETAILS
Proposed
System
CRI
CCT
RSR22-LW-R
RSR22-ML-R
RSR22-HL-R
RSR22-VL-R
RSR24-LW-R
RSR24-ML-R
RSR24-HL-R
RSR24-VL-R
>80
>80
>80
>80
>80
>80
>80
>80
3000K
3000K
3000K
3000K
3000K
3000K
3000K
3000K
Lumens
Input Lumens
Per Fixture Watts Per Watt
2702
3176
3475
4229
3979
4822
5855
7569
30
36
41
52
41
52
62
82
4000K DETAILS
3500K DETAILS
89
89
86
81
97
93
95
93
CCT
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
Lumens
Input Lumens
Per Fixture Watts Per Watt
2853
3237
3662
4470
4196
5079
6192
7967
30
35
41
52
41
52
62
82
94
93
90
86
102
98
101
98
CCT
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
Lumens
Input Lumens
Per Fixture Watts Per Watt
2916
3224
3766
4618
4102
4975
6205
7974
31
36
41
52
41
52
62
82
96
91
93
89
100
96
101
98
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards.
FIXTURE DIMENSIONS
2X4 CROSS SECTION
2X2 CROSS SECTION
4.3125"
4.3125"
24.000"
24.000"
2X4 TOP VIEW
2X2 TOP VIEW
24.000"
24.000"
48.000"
24.000"
*Drawings N.T.S.
Page 3/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RSR
LED Architectural Luminaire
SURFACE MOUNT DIMENSIONS
2X4 DIMENSIONS
2X2 DIMENSIONS
43.250"
5.625"
½"
KO (4) PLCS
3.875"
9.500"
½"
KO (4) PLCS
5.125"
4.625"
1 ½"
13"
1 ½"
12"
*Drawings N.T.S.
CEILING COMPATIBILITY
TYPE G
Side
FLANGE KIT
End
For lay-in installation in exposed grid ceilings. Maximum tee
widths of 1" and maximum tee heights of 2" allowed.
Side
End
For hard ceiling applications order flange kit. Flange kit wires directly
into concealed ceiling opening for a clean, finished appearance.
*Drawings N.T.S.
Page 4/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
Download