RECESSED GB33RC2 LUMINAIRE MOUNTING SYSTEMS Ceiling System Product Code Building The Designation Consists of 3 Digits: Example T9 W A) The First 2 Digits Designate The Ceiling System T9 = 9/16" Flat T Bar T1 = 15/16" Flat T Bar TS = Slot Grid GF = Gyp Type Ceiling with Cover Flange GM = Gyp Type Ceiling Flangeless (Mud Flange) B) The Last Digit Designates The Fixture Attachement Method R = Rod 1/4-20 W = Wire I = Integral W/Grid U = U Brckt. P = Perimeter O D O O O O D O O O O D O O O D NA NA NA NA D NA NA NA NA Partial Product Code - Examples: 1 2 GB33RC2 - 132T8 - 120V EBL - 4' - REC/T9W - - - - GB33RC2 - 128T5 - 120V ERS - 4' - REC/T1W - - - - - 3 GB33RC2 - 128T5 - 120V ERS - 4' - REC/TSW - - - - - 4 GB33RC2 - 128T5 - 120V ERS - 4' - REC/GFR- - - - - 5 GB33RC2 - 128T5 - 120V ERS - 4' - REC/GMR - - - - - Legend: "D" = Default "O" = Optional "NA" = Not Available Illustrations Of Default (D) Mounting Systems FIXTURE BOTTOM IS FLUSH WITH BOTTOM OF T-BAR 1 Building Wire For Support By Others Tie To Structure Retainer Clip W/Spacer 9/16" T Bar System Flange Typ. 3 1/4" 15/16" T Bar System Ceiling Tile 3 5/8" GRID CTRS. 4 FLANGE BELOW CEILING MOUNTING 1/4-20 Threaded Stud By Others To Be Tied To Structure 5/16" Dia X 1" Slot Housing 3" 4" GRID CTRS. 1/2" TYP. GMR 1/4-20 Threaded Stud By Others To Be Tied To Structure 5/16" Dia X 1" Slot Housing 3 1/4" Flange Typ. Gyp Ceiling 3 1/4" Flange Typ. FLANGELESS MOUNT (MUD FLANGE) GFR 5 T1W 3 Building Wire For Support By Others Tie To Structure Retainer Clip W/Spacer 5/16" TYP. 3" Ceiling Tile FIXTURE BOTTOM IS FLUSH WITH BOTTOM OF T-BAR T9W 2 3" 4" Flange to Flange 1/2" Typ. Drywall 3 1/4" Screws Req'd. 5/8" Drywall Plaster Skim Coat 3" 4 3/16" 1/32" Gap Typ. Mud Flange Typ. FIXTURE BOTTOM IS FLUSH WITH BOTTOM OF T-BAR TSW Building Wire For Support By Others Tie To Structure Retainer Clip W/Spacer 9/16" Slot T Bar System Flange Typ. Ceiling Tile 3" 3 5/8" GRID CTRS. 3 1/4" 5/16" TYP. REV. 6-16-10 RECESSED GB33RC2 LUMINAIRE MOUNTING SYSTEMS Partial Product Code - Examples: A B GB33RC2 - 132T8 - 120V EBL - 4' - REC/T1R - - - - GB33RC2 - 128T5 - 120V ERS - 4' - REC/T1I - - - - - - C GB33RC2 - 128T5 - 120V ERS - 4' - REC/T1P - - - - - Illustrations Of Optional (O) Mounting Systems FIXTURE BOTTOM IS FLUSH WITH BOTTOM OF T-BAR A T1R B FIXTURE BOTTOM IS FLUSH WITH BOTTOM OF T-BAR T1I Fixture lays in grid and is supported by the grid only. No external building wire or threaded rod is attached to fixture. 1/4-20 Threaded Stud By Others To Be Tied To Structure 5/16" Dia x 1" Slot Retainer Clip W/Spacer 15/16" T Bar System 3 1/4" 15/16" T Bar System 3 1/4" Flange Typ. 3" Ceiling Tile 4" GRID CTRS. 1/2" TYP. RECESSED/PERIMETER C 1/4-20 Threaded Stud By Others To Be Tied To Structure 2 7/16" Ceiling Tile 3" 4" GRID CTRS. 1/2" TYP. T1P Wall 5/16" Dia X 5/8" Slot Retainer Clip W/Spacer L Bracket By Gammalux 15/16" T Bar System 3 1/4" Ceiling Tile Flange Typ. Flange Typ. 1/2" Wall Bracket By Others 3" 15/16" 4 7/16" Perimeter mounting system can be used with either gyp ceiling or T-bar system. REV. 6-16-10