AHMEDABAD MUNICIPAL CORPORATION (BRIDGE PROJECT DEPARTMENT) TENDER for Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad. Municipal Commissioner Ahmedabad Municipal Corporation. Sardar Patel Bhavan, Nr.Dana pith, AHMEDABAD – 380 001 AHMEDABAD MUNICIPAL CORPORATION AMC"Sardar Patel Bhavan", Danapith, Ahmedabad - 380 001. Tele. Phone: 25391811 / 25391830, Fax: 91-079 -25350926 TENDER NOTICE Municipal Commissioner invites percentage rate sealed tenders from the reputed, experienced & registered contractors of approved class for the work mentioned below. 1. Name of work Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad 2. Time Limit 4 months (Time Limit shall be start after 7 days from the date of work order) 3. Registration 4 Estimated Cost put to tender 5. Earnest Money Deposit 6. Tender fee (Non refundable) Rs.1,23,100/- to be submitted along with the tender in the form of D.D in favour of Municipal Commissioner. Ahmedabad /Bank guarantee of banks approved by AMC's Finance Dept.circular No.22 dt-11.08.2011.as published on AMC's website. Rs.3600/- in the form of D.D in favour of Municipal Commissioner , AHmedabad. 7. Tenders to be downloaded. As per tender notice. 8. Last date of receiving tenders. 9 Date of Opening of Tender As per tender notice. The tenders received after this date and time will not be entertained under any circumstances. (20/10/2011 upto 16.00 hrs.) As per tender notice.(20/10/2011 at 17.00 hrs.) 10. Mode of sending the Tender Documents in duplicate. i.e. two sets Contractor registered in 'AA' class category with AMC or Government of Gujarat or other State Governments, Semi Government bodies or with Central P. W. D. who have adequate experience of having carried out similar type of works. Rs. 12,306,814.85 /- By RPAD or Speed Post, courier or hand delivery only addressed to Asstt. Manager (Project) / PWA Office, 2nd floor, Sardar Patel Bhavan,Ahmedabad Municipal Corporation, Danapith, Ahmedabad, 380001. Price bid shall be submitted online only. 11 Defect Liability Period & Liquidated Damages As mentioned in tender documents. 12. Tender documents will be Tender fees will be paid in form of Demand Draft along made available on web site with submission of Tender. www.egovamc.com Conditional tenders will not be accepted. Municipal Commissioner reserves the rights to reject any or all the tenders without assigning any reasons thereof. Additional City Engineer (Bridge) Ahmedabad Municipal Corporation 2. Information to Tenderers Name of Work: Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad 1 Name of work : Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad 2 Total Estimate Cost : Rs. 12,306,815/- 3 Earnest Money : 4 5 Validity Period of tender Security Deposit : : 6 Retention money : 7 Time allowed for completion of the work Tender document shall be available : Last date of receiving tenders. Mode of sending the tender documents (single bid)And Place of submission of tender document : : 8 9 10 11 Amount to be deducted from each bill for labour welfare fund (non-refundable) Welfare cess act 1996 : Rs.1,23,100/- to be submitted along with the tender the form of D.D in favour of Municipal ommissioner. Ahmedabad /Bank guarantee of banks proved by AMC's Finance Dept.circular No.22 dt.08.2011.as published on AMC's website.(valid upto 150 days from the date of opening of tender) 120 Days from the date of opening of tender. 5 % of the contract value in the form of Demand Draft/Bank guarantee of banks approved by AMC's Finance Dept.circular No.22 dt11.08.2011.as published on AMC's website (valid upto 90 days beyond the date of issuance of completion certificate). 2 % of the contract value to be deducted from each Running Bills 4 months (Tme limit shall be start after 7 days from the date of work order) As per tender notice on website www.egovamc.com or amc.nprocure.com As per tender notice By RPAD or Speed Post, courier or hand delivery only addressed to Asstt. Manager (Project) / PWA Office, 2nd floor, Sardar Patel Bhavan,Ahmedabad Municipal Corporation, Danapith, Ahmedabad, 380001. : Price bid shall be submitted online only. : 1 % of bill amount 12 Tenders, which do not full fill all or any of condition or are submitted incomplete in any respect will be rejected. Municipal Commissioner reserves the rights to reduce / increase the scope of work and contract without assigning any reason thereof. No any claim / dispute in regards to these shall be entertained. 13. 14. 15. No price escalation or price rise difference will be paid for the said work. Conditional tenders will not be accepted. For any dispute relating to the work under contract, Municipal Commissioner's decision will be final & binding to the contractor. Signature of contractor with seal Date Additional City Engineer (Bridge ) Ahmedabad Municipal Corporation TENDER NOTICE 1. The Commissioner, Ahmedabad Municipal Corporation, invites detailed bid from interested parties for the Tender for Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad 2. Necessary documentary evidence shall be submitted along with the tender. Bid Document can be obtained from the AMC website: www.egovamc.com or https://amc.nprocure.com 3. Tender documents, EMD, Tender fees etc shall be sealed in a single envelope and clearly mark as “Tender for Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar” and submitted to the Office of the Assist. Manager (Project), 2nd Floor, Sardar Patel Bhavan, Ahmedabad Municipal Corporation, Ahmedabad, 380 001. Price bid shall be submitted online only. DOWNLOAD OF TENDER DOCUMENT The tender document for these work are available on websitewww.egovamc.com or https://amc.nprocure.com SUBMISSION OF TENDER The completed Tender document shall be submitted online as well as all related documents can be submitted physically as mentioned above at the Office of the Assist. Manager (Project), 2nd Floor, Sardar Patel Bhavan, Ahmedabad Municipal Corporation, Ahmedabad, 380 001. Offers, which are not signed, will not be accepted. Tender copy shall be accompanied by EMD in the form as mentioned in Information to Tenderers. The tenders not submitted in line with the tender clauses and without Tender fee and EMD in the form specified, will be out rightly rejected. - Information for online participation Internet site address for e-Tendering activities will be https://amc.nprocure.com Interested bidders can view detailed tender notice and download tender documents from the above mentioned website. Bidders who wish to participate in this tender need to procure Digital Certificate as per Information Technology Act-2000 using that they can digitally sign their electronic bids. Bidders can procure the same from any of the CCA approved certifying agencies, or they may contact (n) code Solution at below mentioned address and they will assist them in procuring the same. Bidders who already have a valid Digital Certificate need not to procure the same. In case bidders need any clarification regarding online participation, they can contact M/S (n) code Solution 301, G.N.F.C. Info Tower, Near Grand Bhagwati Hotel, Ahmedabad 380015, India. Tel: +91 79 26857316 / +91 79 26857317/ Tel: +91 79 26857318 E-Mail: URL: https://amc.nprocure.com Bidder should upload scan copies of reference documents in support of their eligibility of the bid; However supporting documents may be submitted physically also as mentioned above. After filling data in predefined forms bidders need to click on final submission link to submit their encrypted bid. Bidder should also submit Document Fees, EMD, Technical bid document & Reference Documents in hard copy to the department. 3. Note for Contractors. 1. Tenders once offered shall not be withdrawn except with the permission of Municipal Commissioner. 2. Tender once accepted shall be binding upon the contractor even if the formal agreement is not signed. 3. No Claims shall be paid in case of any variation in the quantities of Bills of Quantities (BOQ) upto any extent. 4. Contractor is requested to see the site physically before tendering. He is also requested to quote the rates keeping in view the points mentioned in relevant pages of tender documents. As this project is time bound, no delay will be allowed. 5. The contractor shall have to submit the tenders in duplicate i.e. two sets-original and duplicate. 6. Before submitting the tenders, Contractors are requested to see the website 24 hrs. before the last date of receiving tenders, for any corrigendum issued. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation 4. Conditions for the Water Supply & Electric Supply Water Supply: The contractor shall arrange at his own cost, a suitable supply of piped wholesome water for the construction of the works and provide a satisfactory supply of potable water for drinking., washing, sanitation and cleaning down, The contractor will be responsible for all the costs where applicable of connection, meter installation, water consumed, water required for testing purposes, disconnection and the laying, maintenance and ultimate removal of any distribution system around the site. If supply by AMC then AMC same will be charged as per Norms of AMC. Electricity: Electric supply shall be made available at the site by Contractor. Contractor must make his own arrangements with Electricity Supply Authorities and with other contractors to connect to and take a supply from such services, paying all costs in Connection therewith. Necessary Documents for getting Electric supply/connection will be arranged by AMC Authority. The Contractor shall be entitled to use such supply. Electricity as may be available on the site for purpose of the work and shall pay such charges as is fixed by the appropriate supply Authorities. In case if there is any delay in supply of power & water at site or any interruption or fault in the power during the work. No compensation shall be paid for idle labor staff, machineries and for use of diesel operating sets etc. as the case may be. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation 5. Tender Declaration form Date: _____________ To Add. City Engineer Ahmedabad Municipal Corporation Ahmedabad. Project: Tender for Construction of False Ceiling and Aluminum Partition work at L.G.Hospital, Maninagar, Ahmedabad Ref: Dear Sir, I/We the undersigned have carefully gone through and clearly understood the Tender documents of above mentioned project comprising of Notice Inviting tenders, Articles of Agreement, Scope of work, Definition of terms, notes Instructions/Information to Tenderer, Condition of Contract, special condition of contract, Appendices, Specifications, Schedule of quantities and tendered drawings furnished by AHMEDABAD MUNICIPAL CORPORATION. I/We have satisfied myself/ourselves as to the location of site, examined drawings. I/We have visited site & fully acquainted with local situations regarding materials, labours & others factors pertaining to work before submitting tenders. I/We do hereby offer to execute and complete the whole of the work within the time specified all in accordance with the specification, designs, drawing and instruction in writing referred to in the said document and with such materials as are provided for, at the respective rates which I/we have quoted in the schedule-B or at such other rates as maybe fixed under the provisions of these conditions. In the event of this tender being accepted I/We agree to enter into an agreement and when required and execute the contract, according to your form of agreement as or in default where of I/we bind myself/ourselves to forfeit the "Earnest Money Deposit." I/We understand that if I/WE shall not enter in agreement within ten days or decided by AMC from the date of receipt of letter of acceptance, you will forfeit the earnest money paid by me/us and take necessary action as deemed fit. I/We have enclosed a Demand Draft / Bank Guarantee as an “Earnest Money Deposit", for the sum as mentioned in NIT, the full value of which is to be absolutely forfeited to the Employer If I/We fail to commence the work specified. Otherwise the Employer shall retain the said sum, as on account of such. Security)' Deposit'.' as provided for in the aforesaid documents. I/We understand that you are not bound to accept the lowest or any tender, which you may receive. I/We am/are bound to execute the job if the work order is issued within 120 days from the date of opening of the tender. I/We agree to pay the Government income-Tax, VAT, Sales-Tax (Central and State) Sales Tax on work consult, and other taxes prevailing from time to time on such items on which the same are livable and the rates quoted by me/us are inclusive of the same. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation FORM ‘A’ BANK GUARANTEE FOR BID SECURITY (EARNEST MONEY) In consideration of the Municipal Corporation of the city of Ahmedabad (hereinafter to as the corporation) having agreed to exempt ______________________ (hereinafter referred to as “the said Contract”) from the demand of security deposit / earnest money in cash for the due fulfillment of the terms and conditions of the agreement made between the corporation and the said contractor on __________________ for _________________________________________________ (hereinafter referred to us “the said agreement”) on production of Bank Guarantee for Rs. ___________________ Rupees ___________________________________________________ only. We ______________________________________________ Bank (hereinafter referred to as “Bank”) do hereby undertake to pay to the Corporation as a amount not exceeding Rs. _____________ Rupees _____________________________________________ only on the demand from Corporation. Any such demand on the bank shall be conclusive as regards as amount due and payable by the bank under this guarantee. However, liability of the bank under this agreement shall restricted to as amount not exceeding Rs. ___________________Rupees _________________________________________only. We the bank further agree that the guarantee herein contain shall remain in full force and effect during the period that would be taken for the performance of the said agreement and that it shall continue to be enforceable till all the dues of the Corporation under or virtue of the said agreement have been paid and its claim satisfied or discharged and till a certificate to the effect has been received by the bank from the Corporation. However, unless the demand of claim under the guarantee is made to the bank in writing on or before the ________________________ (specify the date) the bank shall be discharged from all liabilities under this guarantee. With the bank further with Corporation shall have fullest liberty, without the concert of the bank without effecting in any manner it obligations herein under to vary any of the terms and conditions of the said agreement or extend time for performance by the said contract from time to time or to postpone for any time or from time to time any of the powers exercisable by the Corporation against the said Contractor and to forebear to enforced any of the terms and conditions relating to the said agreement and the bank shall not be relieved from liability by reason of any such variation, or extension granted to the contractor for any forbearance, at all omission on the part of the Corporation or any indulgence by the Corporation to the said Contractor or by any such matter or thing whatsoever which under the law relating to sureties would, but this provision, have the effect of so relieving the Bank. We _____________________________________________ the bank undertake not to revoke the Guarantee during currency except with the previous concert of the Corporation in writing. Dated the _______________________ day of __________________ of 20___________ For _______________________________ Bank Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation BANK GUARANTEE FOR BID SECURITY To: ____________________________ [name of Employer] ____________________________ [address of Employer] WHEREAS _______________________________ [name and address of Contractor] (here-in after called “the Contractor") has undertaken, in pursuance of Contract No. __________ dated ______________ to execute ___________________________ [name of Contract and brief description of Works] (hereinafter called “the Contract"); AND WHEREAS it has been stipulated by you in the said Contract that the Contractor shall furnish you with a Bank Guarantee by a recognized bank for the sum specified therein as security for compliance with his obligations in accordance with the Contract; AND WHEREAS we have agreed to give the Contractor such a Bank Guarantee; NOW THEREFORE we hereby affirm that we are the Guarantor and responsible to you, on behalf of the Contractor, up to a total of ____________________________________________ [amount of Guarantee]1 _______________________________ [in words], such sum being payable in the types and proportions of currencies in which the Contract Price is payable, and we undertake to pay you, upon your first written demand and without cavil or argument, any sum or sums within the limits of _____________________________ [amount of Guarantee] as aforesaid without your needing to prove or to show grounds or reasons for your demand for the sum specified therein. We hereby waive the necessity of your demanding the said debt from the Contractor before presenting us with the demand We further agree that no change or addition to or other modification of the terms of the Contract or of the Works to be performed there under or of any of the Contract documents which may be made between you and the Contractor shall in any way release us from any liability under this guarantee, and we hereby waive notice of any such change, addition or modification This guarantee shall be valid until the date of issue of the Defects Liability Certificate. SIGNATURE AND SEAL OF THE GUARANTOR_____________________ Name of Bank ___________________________ Address ___________________________ Date ___________________________ Signature/Stamp of Contractor Ahmedabad Add. City Engineer Municipal Corporation 7. List of Approved Banks ALL NATIONALIZED BANK OR BANKS APPROVED BY AMC Finance Department Circular No.22 Dated 11.08.2011 as published on AMC's website www.egovamc.com. 8. Damage to persons and property : The contractor shall be liable for and shall indemnify the Employer against any liability, loss, claim or proceedings whatsoever arising under any statute or at common law in respect of personal injury to or the death of any person whomsoever arising out of or in the course of or caused by the carrying out the works, unless due to any act or neglect of the Employer or of any person for whom the Employer is responsible. The contractor shall be responsible for all injury to persons, animals or things, and for allstructural and decorative damage to property which may arise from the operation or neglect of himself or of any nominated sub-contractor's employees, whether such injury or damage arise from carelessness, accident or any other cause what ever in any way connected with the carrying out of this contract. This clause shall be held to include, interalia,, any damage to buildings, whether immediately adjacent or otherwise and damage to roads, streets, good paths, bridges or way as well as all damage caused to the buildings and works forming the subject of this contract by frost or other inclemency of weather. The contractor shall indemnify the employer and hold him harmless in respect of all and any expenses arising from any such injury or damage to persons or property as aforesaid and also in respect of any claim made in respect of injury or damage under any acts of government or otherwise and also in respect of any award of compensation or damages consequent upon such claim. The contractor shall reinstate all damages of every sort mentioned in this clause, at his own cost, so as to deliver up the whole of the contractor works complete and perfect in every respect and so as to make good or otherwise satisfy all claims for damage to the property of third parties. The contractor shall indemnify the employer against all claims which may be made against the employer by any member of the public or other third party in respect of anything which may arise in respect of the work or in consequence thereof and shall at his own expense arrange to effect and maintain until the virtual completion of the contract, against all claims which may be made upon the employer whether under the workmen's compensation act or any other statute in force during the currency of this contract or at common law in respect of any employee of the contract or any subcontractor and shall at his own expense effect and maintain, until the virtual completion of the contract. He shall also indemnify the employer in respect of any costs, charges or expenses arising out of any claim or proceeding and also in respect of any award of or compensation of damage arising there form. The employer with the concurrence of Architect shall be at liberty and is hereby empowered to deduct the amount of any damage, compensation, costs charges and expenses arising or accruing from or in respect of any such claim or damage from any sum or sums due or to become duet to the contractor. 9. Clause for Extra Item: -If any extra item crops up during the progress of work the same shall be carried out by the Contractor and he shall be paid at the rate fixed by City Engineer which shall be fixed as lowest of the rates derived by rate analysis based on the following two methods. (i) Rate analysis based on approved BOQ item rates or Govt. SOR 2011-12(Ahmedabad Division)plus or minus contractor’s tender premium or rebate as the case may be. (ii) Rate analysis based on current market rates. This shall be based on • The material costs, the labour costs, the cost of use of all plant, machinery and equipment, the cost of all temporary and incidental works, the overheads and the Contractors profit. • The overheads shall be taken at 3 % of the sum of material costs, the labour costs, the cost of use of all plant, machinery and equipment, the cost of all temporary and incidental works. • The Contractors profit shall be taken at 10 % of the sum of material costs, the labour costs, the cost of use of all plant, machinery and equipment, the cost of all temporary and incidental works, the overheads. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation DECLARATION: I / We hereby declare that I / we have visited the site and fully acquainted myself/ ourselves with the local situations regarding materials, labour and other factors pertaining to the work before submitting this tender. I / We hereby declare that I / we have carefully studied all the terms and conditions of contract, specifications mentioned in the tender documents and I / We do agree for compliance with the same strictly. I/We shall execute the contract agreement with the AMC after award of work and before start of work. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation SPECIAL NOTE Clause: 1 No contractor shall employ any child having age up to 14 years, as it is prohibited by child labour regulation act-1986. Hon. Supreme Court has given certain guide lines and as per guide lines, if employment of detected on the site work the employer is contractor shall have to deposit Rs. 20,000/- (Rupees twenty thousand only) in the welfare fund. If the employer refuses to deposit then action will be taken for contempt of court of Supreme Court judgment and prosecuted by concern authority. Because of the breach of any provision child prohibition and Regulation Act – 1986 by the contractor and for the Corporation has to pay any amount then the Municipal Corporation shall recover the said amount from the contractor. Clause: 2 All necessary testing charges shall be borne by Bidder. Signature/Stamp of Contractor Add. City Engineer Ahmedabad Municipal Corporation General conditions 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Wherever a reference to any Indian standard appears in the specifications, it shall be taken to mean as reference to the latest edition of the same of force on the date of agreement. In "Mode of Measurement" in the specifications wherever a dispute arises in the absence of specific mention for a particulars point / aspect, the same in the relevant Indian Standards shall be referred to. All measurement and computations, unless otherwise specified shall be carried out nearest to the following limits :i) Length, width and depth, Height 0.01 Meter ii) Areas 0.01 Sq.mts. iii) Cubic contents 0.01 Cu. mts. In recording dimensions of work, the sequence of length, width and height (Depth) or thickness shall be followed. Definite particulars covered in the items of work, though not mentioned or elucidate in its specifications shall be deemed to be included therein. Approval of the samples of various materials given by the Engineer in charge shall not absolve the contractor from the responsibility of replacing defective materials brought on site or materials used in the work found defective at a later date. The contractor shall have no claim to any payment or compensation whatsoever on account of any such materials being rejected by the Engineer in charge. The contractor’s rate for the item of work shall be for the work completed in all respect. Materials, as and when rejected by the Engineer in charge shall be removed from the site of work within 24 hours. All work shall be carried out in a manner applying the best technique. All tools, templates, machinery and equipment for correct execution of the work as well as for checking lines, levels, alignment of the works & all precautionary measures during execution shall have to be kept in sufficient numbers and in good working condition at the site of the work. Special modes of the construction not adopted in general Engineering practice, if proposed to be adopted by the contractor shall be considered only if the contractor provided satisfactory evidence that such special mode of construction and completion of work to the required strength and quality. Acceptance of the same by the Engineer in charge shall not however, absolve the contractor from the responsibility of any adverse effect and concordance of adopting the same in the course of exaction or completion of the work. The contractor shall be responsible for observing the rules and regulation imposed under the "Minor Mineral Act", and such other laws and rules prescribed by the Government from time to time. All necessary safety measures and precautions (incl. those laid down in the various relevant Indian Standard)/ traffic diversion work if required shall be taken to engrave the safety of men, materials and machinery on the work and also of the work itself. Quantity measured in the tender is approximate. It may increase or decrease upto any extent, looking to the quantum of actual work, for which no any claim shall be entertained for the same. The work in general shall be carried out as per standard specifications of the respective item of work to be executed & also as per direction of 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. consultant/Medical equipment Consultant/ Air-conditioning consultant, AMC engineers/ Medical authorities. The general terms & conditions of the contract shall be applicable & shall be binding on the contractor. The contract agreement shall have to be executed between AMC & the agency to whom work is awarded for execution. The time limit shall be reckoned after the seven days, from the date of issue of the written work order to the contractor. No time extension will be granted under any circumstances. In case of any ambiguity in specifications mentioned in this tender, the interpretation given by Additional City Engineer (Bridge Projects) of A.M.C. will be final and binding to the Contractor. The testing charges for materials shall be born by the contractor. No price escalation or price rise difference will be paid for the said work Contractor shall have to enclose the copies of required documents along with the tender like - valid registration, Income tax clearance certificate, Experience certificate & EMD, etc. failing which his tender shall be liable for rejection. The rate quoted by the contractor shall be inclusive the cost of all materials, labors, prevailing municipal charge/octroi, Central/State govt. taxes & also the cost of precautionary measures & incidental charges/overheads etc. as per tender condition. Defect Liability period for the tender shall be 1(one ) year after the date of completion of work. Contractor shall submit bank guarantee against defect liability period of 5% of contract value, which shall be released after completion of defect liability period. Liquidated damages: If contractor fails to complete the work within specified timelimit as mentioned in tender document, contractor shall pay 0.01% of the contract value per day. Maximum value of the liquidated damage shall be 10% of the contract value. No advance such as machinary advance, mobilization advance or material advance will be given. The retention money shall be released along with release of payment of final bill ,after the satisfactory completion of work. Conditional tenders will not be accepted. Municipal Commissioner reserves the rights to reject any or all the tenders without assigning any reasons thereof. -Dispute Review Expert /Arbitration - In case of all the disputes, decision of the Municipal Commissioner, Ahmedabad shall be final and binding to the bidder. Municipal Commissioner shall be the sole Arbitrator. PRICE VARIATION CLAUSE :NOT APPLICABLE Signature of contractor with seal Date Additional City Engineer (Bridge ) Ahmedabad Municipal Corporation. SPECIFICATIONS ITEM NO. : 001 ITEM SPECIFICATION FOR, AEROLITE CEILING TILES QUADRA IN “ P GRID “24 MM PROFILE GRID. Calcium Silicate Ceiling Tiles : Providing & Fixing “AEROLITE” make Light weight calcium Silicate Ceiling Tiles (Quadra) of size 600 X 600 having 15 MM densified Tegular Edges with 90 NRC Value With “ P-Grid ” Brand Precoted “ SILHOUTE “ Main Runner 3.00 MTR Length of Section 42 X 15 Cross Tee 1.20M of section 32 X 15 MM. The Wall Angle Shall be fixed on PVC dash Fastners on the Perimeter of the wall by Steel screws with distance of 1 Feet apart Where main Runner 3.60 M Shall be Parallel to Width & Perpendicular to Length Shall be Placed dully Inter-Connected. The Distance Between two main runners to be maintained at 1.2M. The Cross Tee 1.2 M will be Inserted in the Pre-Cut Slots of Main Runner on Regular Interval of 600M to Form a modular Grid of 1.20 X 600 M . Additional Cross Tee of 600 MM Shall Be Placed Parallel to Length to Form a Grid of 600 MM X 600 MM. P-Grid of Module size 600 Mm X 600MM Shall be Supported By 4/6 MM Dia G.I.Wire from the Purlins/ Soffit. Completed with all material & Labour as per instruction of architect. (rates inclusive of necessary scaffolding required) Note: i) only Calcium Silicate False ceiling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS- 476 – PART IV –– CALCIUM SILICATE -INCOMBUSTIBILITY IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: A grid of section 600 MM X 600 MM is to be made up of G.I. T sections wherein the main tee is duly suspended from the RCC slab roof. The sizes of the members shall be as under & the entire grid should be able to take a suspended load of minimum 18 kg/Sqm. Perimeter Wall Angle: 0.40 MM Thick gauge having equal flanges of size 22 MM made from pre-coated G.I.Coil of length 3.0m. Main Tees of 3.60M / 3.0 M length having a web height of 42 MM with a 8 MM Blub at the top having an exposed bottom of 15 MM silhoute capped with a Precoated G.I.coil wherein the coil thickness is 0.33 MM. Cross Tees of length 1.20 M & 0.60 M having a web height of 32 MM & an exposed bottom of 15 MM Silhoute capped with Pre-coated G.I. coil wherein the coil thickness is 0.33mm. The Grid shall be standard quality like P – GRID b) Ceiling tile: Light weight Calcium Silicate Tiles and made from hydrated Calcium silicate, reinforcing fibers natural fillers free from formaldehyde & other harmful materials shall not contain any toxic ingredients. The tiles shall be of size 595 Mm X 595 Mm having reinforced edges of 24 MM thickness all around in a collar of width 24 MM and 10 MM thickness at the center. The tiles shall have an overall density of 350 Kg/M3 in the body and 450 Kg/ m3 at the edges. The tiles shall be primer coated on both sided and the fair surface shall be having a factory finish in two coats of white dispersion type solvent free paint. The tiles should be characterized with 100 % relative humidity resistance, incombustibility as per BS 476, Part IV, thermal conductivity of 0.043w/mo KC , and light reflectance > 85 % and an NRC of 0.90 (Sound attenuation: 32 dB). The Tiles should weight approx. 5.5 Kg/m2. The Tiles shall be ecofriendly and using more than 50 % recycled material. FIXING THE G.I.SUSPENSION SYSTEM TO THE CEILING: The main runners of size silhoute 42 MM X 15 MM X 3.00 MM length spaced at 1200 MM centers shall be securely suspended with G.I.Suspension wire of 4 MM dia. With necessary level adjusters made from spring steel with adequate tension in one direction. The G.I. wire is to be suspended at 1200 mm centers from the soffit with the aid of soffit cleats made of zinc alloy having dimension 25 mm X 35 MM X 1.6 MM secured to the soffit with metal dash fastners of size 6 MM X 50 MM. The last hanger at the end of each main runner should not be greater than 600 MM from the adjacent wall. Then flush fitting cross tees of size 15 mm centers at right angles to the main tees, 600 MM X 600 Mm modules are then to be formed by fitting cross tees of size 32 MM X 15 MM X 0.6 Mm length centrally between the longer cross Tees. The system shall rest on periphery walls / partition on the wall angle of section 0.40 Mm thick gauge having equal flanges of 22 MM made from Precoated G.I.coil of length 3.0m. The entire grid system shall be designed to bear a distributed load of minimium 15 Kg/ Sq.M. (a) Storage and Handling precautions: 1. 2. 3. 4. 5. Aerolite ceiling tiles shall have be supplied in neatly packed cartons. Not to store the cartons in flat and wet locations. Handle cartons and individual tiles with care. Do not drop or stand cartons or tiles or edges or corners. Open cartons completely and using both hands with protective gloves, remove tiles in pairs with fair faces together. (b) Installation precautions: The following to be ensured before installation of the ceiling system. a) b) c) d) e) The area is dry prior to ceiling installation work. All wet trades are completed such as plastering, flooring etc. Air conditioning duct work is completed Electrical chasing or drawing lines etc. are in place. No unauthorized weight is put on ceiling. Lighting fixtures to be suspended independently. f) Calcium silicate Tiles should be installed by experienced contractors in compliance with manufactures specifications & conditions. g) Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. h) Calcium Silicate tiles shall not be used to support any unauthorized loads. i) Calcium Silicate tiles shall be mechanically suspended properly & shall not be cemented nor glued to the surface of any other material. CUTOUTS FOR LIGHT AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: a) Aerolite Ceiling tiles are an Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). b) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. c) Acoustic Properties: The tiles offer an average NRC of 0.90 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The tiles are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES a) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. b) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. : 002 ITEM SPECIFICATION FOR, GYPSUM FALSE CEILING Gypsum Ceiling : Providing & Fixing at all height false ceiling of 12.50 MM Thick tapered edge Gypsum Board conforming to IS:2095 including providing & fixing of frame work made of special section power pressed from M.S.Sheet & galvanized in accordance with zinc coating 600 as per IS:277 & Consisting Angle cleats of size 25mm wide X 16 mm thick with flanges of 22 mm& 37 mm at 1200mm center to center one flange to the ceiling with desh fastner 12.5 mm dia X 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x 5 mm of required length & other end of angle hanger being fixed with nut & bolts to G.I.Channels 45 mm X 15mm X 0.90 mm running at the rate of 1200 mm center to center to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5mm at 450 mm center shall be fixed in a direction perpendicular to G.I.Channel with connecting clips made out of 2.64 mm dia X 230 mm long G.I.wire at every junction including fixing the gypsum Board with ceiling section & perimeter channels 3.5 mm thick 27 mm high having flanges of 20 mm & 30 mm long. the perimeter of ceiling to wall partition with the help of rawl plugs at 450 mm center to center with 25 mm long drive all screws @ 230 mm interval including jointing & fixing to a dust finish of tapered & square edges of the gypsum board with recommended filler , Paper tapes, finisher & two coats of primer suitable for gypsum board as per manufactures specification & also including the coat of making openings for Light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitable fixed all complete as per drawing & specification & direction of the Engineer – in –charge but excluding the coat of Painting. (rates inclusive of necessary scaffolding required) Note: i) only gypsum board False ceiling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS- 476 – PART IV –– GYPSUM BOARD IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: frame work made of special section power pressed from M.S.Sheet & galvanized in accordance with zinc coating 600 as per IS:277 & Consisting Angle cleats of size 25mm wide X 16 mm thick with flanges of 22 mm& 37 mm at 1200mm center to center one flange to the ceiling with desh fastner 12.5 mm dia X 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x 5 mm of required length & other end of angle hanger being fixed with nut & bolts to G.I.Channels 45 mm X 15mm X 0.90 mm running at the rate of 1200 mm center to center to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5mm at 450 mm center shall be fixed in a direction perpendicular to G.I.Channel with connecting clips made out of 2.64 mm dia X 230 mm long G.I.wire at every junction including fixing the gypsum Board with ceiling section & perimeter channels 3.5 mm thick 27 mm high having flanges of 20 mm & 30 mm long. the perimeter of ceiling to wall partition with the help of rawl plugs at 450 mm center to center with 25 mm long drive all screws @ 230 mm interval including jointing & fixing to a dust finish of tapered & square edges of the gypsum board . b) Ceiling Board: gypsum board of saint-gobin gyproc india ltd make of size:1220x1830x12.5mm thick. FIXING THE G.I.SUSPENSION SYSTEM TO THE CEILING: Providing & Fixing at all height false ceiling of 12.50 MM Thick tapered edge Gypsum Board conforming to IS:2095 including providing & fixing of frame work made of special section power pressed from M.S.Sheet & galvanized in accordance with zinc coating 600 as per IS:277 & Consisting Angle cleats of size 25mm wide X 16 mm thick with flanges of 22 mm& 37 mm at 1200mm center to center one flange to the ceiling with desh fastner 12.5 mm dia X 40 mm long with 6 mm dia bolts to the angle hangers of 25 x 25 x 5 mm of required length & other end of angle hanger being fixed with nut & bolts to G.I.Channels 45 mm X 15mm X 0.90 mm running at the rate of 1200 mm center to center to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5mm at 450 mm center shall be fixed in a direction perpendicular to G.I.Channel with connecting clips made out of 2.64 mm dia X 230 mm long G.I.wire at every junction including fixing the gypsum Board with ceiling section & perimeter channels 3.5 mm thick 27 mm high having flanges of 20 mm & 30 mm long. the perimeter of ceiling to wall partition with the help of rawl plugs at 450 mm center to center with 25 mm long drive all screws @ 230 mm interval including jointing & fixing to a dust finish of tapered & square edges of the gypsum board with recommended filler , Paper tapes, finisher & two coats of primer suitable for gypsum board as per manufactures specification & also including the coat of making openings for Light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitable fixed all complete as per drawing & specification & direction of the Engineer – in –charge but excluding the coat of Painting. (rates inclusive of necessary scaffolding required) (a) Storage and Handling precautions: 6. 7. 8. 9. Gypsum board shall have be supplied in loose packing. Not to store the cartons in flat and wet locations. Handle individual nos with care. Do not drop or stand board or edges or corners. (b) Installation precautions: The following to be ensured before installation of the ceiling system. j) k) l) m) n) o) p) q) r) The area is dry prior to ceiling installation work. All wet trades are completed such as plastering, flooring etc. Air conditioning duct work is completed Electrical chasing or drawing lines etc. are in place. No unauthorized weight is put on ceiling. Lighting fixtures to be suspended independently. Gypsum ceiling should be installed by experienced contractors in compliance with manufactures specifications & conditions. Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. Gypsum ceiling shall not be used to support any unauthorized loads. Gypsum ceiling shall be mechanically suspended properly & shall not be cemented nor glued to the surface of any other material. CUTOUTS FOR LIGHT AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: d) Gypsum Ceiling are an Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). e) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. f) Acoustic Properties: The tiles offer an average NRC of 0.50 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The board are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES c) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. d) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. :03 ITEM SPECIFICATION FOR, E/V BOARD TILES IN “P”GRID 24MM PROFILE FALSE CEILING E BOARD (in toilets): Providing & Fixing 6MM THICK E-BOARD Ceiling Panel Pattern Of Size 600 X 600 X 6 MM Thick with Color Butt Edge to be Placed in the E-Grid Suspended Ceiling Grid System No. 2430 With Main Runner 3.60 MTR Length of Section 38 x 24 Cross Tee 1.20M of section 24 X 24 MM. The Wall Angle Shall be fixed on PVC dash Fasteners on the Perimeter of the wall by Steel screws with distance of 1 Feet apart Where main Runner 3.60 M Shall be Parallel to Width & Perpendicular to Length Shall be Placed dully Inter-Connected. The Distance Between two main runners to be maintained at 1.2M. The Cross Tee 1.2 M will be Inserted in the Pre-Cut Slots of Main Runner on Regular Interval of 600M to Form a modular Grid of 1.20 X 600 M . Additional Cross Tee of 600 MM Shall Be Placed Parallel to Length to Form a Grid of 600 MM X 600 MM. E-Grid of Module size 600 Mm X 600MM Shall be Supported By 4/6 MM Dia G.I. Wire from the Purlins/ Soffit. With Butterfly clip with all material & Labor etc. completed with three coats of color on putty. (rates inclusive of necessary scaffolding required) Note: i) only E-board False ceiling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS- 476 – PART IV –– Fiber cement board -INCOMBUSTIBILITY IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: A grid of section 600 MM X 600 MM is to be made up of G.I. T sections wherein the main tee is duly suspended from the RCC slab roof. The sizes of the members shall be as under & the entire grid should be able to take a suspended load of minimum 18 kg/Sqm. Perimeter Wall Angle: 0.40 MM Thick gauge having equal flanges of size 22 MM made from pre-coated G.I.Coil of length 3.0m. Main Tees of 3.60M / 3.0 M length having a web height of 38 MM with a 8 MM Blub at the top having an exposed bottom of 24 MM capped with a Precoated G.I.coil wherein the coil thickness is 0.33 MM. Cross Tees of length 1.20 M & 0.60 M having a web height of 28 MM & an exposed bottom of 24 MM capped with Pre-coated G.I. coil wherein the coil thickness is 0.33mm. The Grid shall be standard quality like P - GRID/E - GRID equivalent b) Ceiling tile: Fiber cement board tiles of E/V board made from hydrated fiber cement, reinforcing fibers natural fillers free from formaldehyde & other harmful materials shall not contain any toxic ingredients. The tiles shall be of size 595 Mm X 595 Mm having reinforced edges of 6 MM thickness all around in The tiles shall have an overall density of 350 Kg/M3 in the body. The tiles should be characterized with 100 % relative humidity resistance, incombustibility as per BS 476, Part IV, thermal conductivity of 0.043w/mo KC , and light reflectance > 85 % and an NRC of 0.90 (Sound attenuation: 32 dB). The Tiles should weight approx. 5.5 Kg/m2. The Tiles shall be eco-friendly and using more than 50 % recycled material. FIXING THE G.I.SUSPENSION SYSTEM TO THE CEILING: The main runners of size 38 MM X 24 MM X 3.60 MM length spaced at 1200 MM centers shall be securely suspended with G.I.Suspension wire of 4 MM dia. With necessary level adjusters made from spring steel with adequate tension in one direction. The G.I. wire is to be suspended at 1200 mm centers from the soffit with the aid of soffit cleats made of zinc alloy having dimension 25 mm X 35 MM X 1.6 MM secured to the soffit with metal dash fastners of size 6 MM X 50 MM. The last hanger at the end of each main runner should not be greater than 600 MM from the adjacent wall. Then flush fitting cross tees of size 28 mm centers at right angles to the main tees, 600 MM X 600 Mm modules are then to be formed by fitting cross tees of size 28 MM X 24 MM X 0.6 Mm length centrally between the longer cross Tees. The system shall rest on periphery walls / partition on the wall angle of section 0.40 Mm thick gauge having equal flanges of 22 MM made from Precoated G.I.coil of length 3.0m. The entire grid system shall be designed to bear a distributed load of minimium 15 Kg/ Sq.M. (a) Storage and Handling precautions: 10. E/V board ceiling tiles shall have be supplied in neatly packed cartons. 11. Not to store the cartons in flat and wet locations. 12. Handle cartons and individual tiles with care. 13. Do not drop or stand cartons or tiles or edges or corners. 14. Open cartons completely and using both hands with protective gloves, remove tiles in pairs with fair faces together. (b) Installation precautions: The following to be ensured before installation of the ceiling system. s) t) u) v) w) The area is dry prior to ceiling installation work. All wet trades are completed such as plastering, flooring etc. Air conditioning duct work is completed Electrical chasing or drawing lines etc. are in place. No unauthorized weight is put on ceiling. Lighting fixtures to be suspended independently. x) E/V board Tiles should be installed by experienced contractors in compliance with manufactures specifications & conditions. y) Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. z) E/V board tiles shall not be used to support any unauthorized loads. aa) E/V board tiles shall be mechanically suspended properly & shall not be cemented nor glued to the surface of any other material. CUTOUTS FOR LIGHT AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: g) E/V board Ceiling tiles are an Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). h) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. i) Acoustic Properties: The tiles offer an average NRC of 0.90 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The tiles are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES e) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. f) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. : 004 ITEM SPECIFICATION FOR, MINERAL FIBER CEILING TILES FINE FISSURED IN “ P “ 24 MM PROFILE GRID. Mineral Fiber Ceiling Tiles (Finefissured ) : The ceiling to be constructed of ANF RH 90 or equivalent mineral FIBER with 0.5 NRC and sound attenuation (CAC) of 30 dB ,Angled Tegular ceiling tiles of size 600mmx600mmx14mm (thickness) and weight of 2.7 Kg/ Sq Mtr having fire performance class A, Laid into a SYSTEM C exposed grid system consisting of main runners spaced at 1200 mm centers securely fixed to the structural soffit by approved hangers at maximum 1200 mm centers. There should be a minimum of 1 hanger per 1.5 sq.metres of ceiling area and the last hanger should not be further than 450 mm from the adjacent wall.1200 mm cross tees to be fixed between main runners at 600 mm centers to form 600 x 600 mm module and 600 mm cross tees fitted centrally between 1200 mm cross tees to create 600 x 600 mm module. (rates inclusive of necessary scaffolding required. Note: i) only mineral fiber False ceiling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS- 476 – PART IV –– MINERAL FIBER CEILING TILES-INCOMBUSTIBILITY IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: A grid of section 600 MM X 600 MM is to be made up of G.I. T sections wherein the main tee is duly suspended from the RCC slab roof. The sizes of the members shall be as under & the entire grid should be able to take a suspended load of minimum 18 kg/Sqm. Perimeter Wall Angle: 0.40 MM Thick gauge having equal flanges of size 22 MM made from pre-coated G.I.Coil of length 3.0m. Main Tees of 3.60M / 3.0 M length having a web height of 38 MM with a 8 MM Blub at the top having an exposed bottom of 24 MM capped with a Precoated G.I.coil wherein the coil thickness is 0.33 MM. Cross Tees of length 1.20 M & 0.60 M having a web height of 28 MM & an exposed bottom of 24 MM capped with Pre-coated G.I. coil wherein the coil thickness is 0.33mm. The Grid shall be standard quality like P - GRID/ARMSTRONG / ANUTONE equivalent b) Ceiling tile: Light weight mineral fiber Tiles and made from natural mineral, reinforcing fibers natural fillers free from formaldehyde & other harmful materials shall not contain any toxic ingredients. The tiles shall be of size 595 Mm X 595 Mm having reinforced edges of 15 MM thickness. The tiles shall have an overall density of 350 Kg/M3 in the body and 450 Kg/ m3 at the edges. The tiles shall be primer coated on both sided and the fair surface shall be having a factory finish in two coats of white dispersion type solvent free paint. The tiles should be characterized with 100 % relative humidity resistance, incombustibility as per BS 476, Part IV, thermal conductivity of 0.043w/mo KC , and light reflectance > 85 % and an NRC of 0.90 (Sound attenuation: 32 dB). The Tiles should weight approx. 5.5 Kg/m2. The Tiles shall be ecofriendly and using more than 50 % recycled material. FIXING THE G.I.SUSPENSION SYSTEM TO THE CEILING: The main runners of size 32 MM X 24 MM X 3.60 MM length spaced at 1200 MM centers shall be securely suspended with G.I. Suspension wire of 4 MM dia. With necessary level adjusters made from spring steel with adequate tension in one direction. The G.I. wire is to be suspended at 1200 mm centers from the soffit with the aid of soffit cleats made of zinc alloy having dimension 25 mm X 35 MM X 1.6 MM secured to the soffit with metal dash fasteners of size 6 MM X 50 MM. The last hanger at the end of each main runner should not be greater than 600 MM from the adjacent wall. Then flush fitting cross tees of size 28 mm centers at right angles to the main tees, 600 MM X 600 Mm modules are then to be formed by fitting cross tees of size 26 MM X 24 MM X 0.6 Mm length centrally between the longer cross Tees. The system shall rest on periphery walls / partition on the wall angle of section 0.40 Mm thick gauge having equal flanges of 22 MM made from Precoated G.I.coil of length 3.0m. The entire grid system shall be designed to bear a distributed load of minimum 15 Kg/ Sq.M. (a) Storage and Handling precautions: 15. Mineral fiber ceiling tiles shall have be supplied in neatly packed cartons. 16. Not to store the cartons in flat and wet locations. 17. Handle cartons and individual tiles with care. 18. Do not drop or stand cartons or tiles or edges or corners. 19. Open cartons completely and using both hands with protective gloves, remove tiles in pairs with fair faces together. (b) Installation precautions: The following to be ensured before installation of the ceiling system. bb) The area is dry prior to ceiling installation work. cc) All wet trades are completed such as plastering, flooring etc. dd) Air conditioning duct work is completed ee) Electrical chasing or drawing lines etc. are in place. ff) No unauthorized weight is put on ceiling. Lighting fixtures to be suspended independently. gg) Mineral fiber Tiles should be installed by experienced contractors in compliance with manufactures specifications & conditions. hh) Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. ii) Mineral fiber tiles shall not be used to support any unauthorized loads. jj) Minearl fiber tiles shall be mechanically suspended properly & shall not be cemented nor glued to the surface of any other material. CUTOUTS FOR LIGHT AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: j) Mineral fiber Ceiling tiles are an Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). k) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. l) Acoustic Properties: The tiles offer an average NRC of 0.90 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The tiles are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES g) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. h) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. :005 ITEM SPECIFICATION FOR, METAL CEILING TILES FINE FISSURED IN “ P “ GRID 24 MM PROFILE GRID. Metal tiles : Providing & Fixing Metal tiles of size 595 X 595 X 0.50 MM Thick Tegular Edge with 0.40 NRC Value “P GRID” With Main Runner 3.60 MTR Length of Section 38 X 15 Cross Tee 1.20M of section 24 X 15 MM. The Wall Angle Shall be fixed on PVC dash Fastners on the Perimeter of the wall by Steel screws with distance of 1 Feet apart Where main Runner 3.60 M Shall be Parallel to Width & Perpendicular to Length Shall be Placed dully Inter-Connected. The Distance Between two main runners to be maintained at 1.2M. The Cross Tee 1.2 M will be Inserted in the Pre-Cut Slots of Main Runner on Regular Interval of 600M to Form a modular Grid of 1.20 X 600 M . Additional Cross Tee of 600 MM Shall Be Placed Parallel to Length to Form a Grid of 600 MM X 600 MM. E-Grid of Module size 600 Mm X 600MM Shall be Supported By 4/6 MM Dia G.I.Wire from the Purlins/ Soffit.etc. Completed with all material & Labour as per instruction of architect. Note: i) only Metal False ceiling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS- 476 – PART IV –– METAL FALSE CEILING -INCOMBUSTIBILITY IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: A grid of section 600 MM X 600 MM is to be made up of G.I. T sections wherein the main tee is duly suspended from the RCC slab roof. The sizes of the members shall be as under & the entire grid should be able to take a suspended load of minimum 18 kg/Sqm. Perimeter Wall Angle: 0.40 MM Thick gauge having equal flanges of size 22 MM made from pre-coated G.I.Coil of length 3.0m. Main Tees of 3.60M / 3.0 M length having a web height of 38 MM with a 8 MM Blub at the top having an exposed bottom of 24 MM capped with a Precoated G.I.coil wherein the coil thickness is 0.33 MM. Cross Tees of length 1.20 M & 0.60 M having a web height of 28 MM & an exposed bottom of 24 MM capped with Pre-coated G.I. coil wherein the coil thickness is 0.33mm. The Grid shall be standard quality like P - GRID/ARMSTRONG / ANUTONE equivalent b) Ceiling tile: Metal Tiles made from galvanize sheet of 0.50mm thick and the size of tiles is:-595x595x0.50mm thick teguler edge with 0.40 NRC value. FIXING THE G.I.SUSPENSION SYSTEM TO THE CEILING: The main runners of size 32 MM X 24 MM X 3.60 MM length spaced at 1200 MM centers shall be securely suspended with G.I.Suspension wire of 4 MM dia. With necessary level adjusters made from spring steel with adequate tension in one direction. The G.I. wire is to be suspended at 1200 mm centers from the soffit with the aid of soffit cleats made of zinc alloy having dimension 25 mm X 35 MM X 1.6 MM secured to the soffit with metal dash fastners of size 6 MM X 50 MM. The last hanger at the end of each main runner should not be greater than 600 MM from the adjacent wall. Then flush fitting cross tees of size 28 mm centers at right angles to the main tees, 600 MM X 600 Mm modules are then to be formed by fitting cross tees of size 26 MM X 24 MM X 0.6 Mm length centrally between the longer cross Tees. The system shall rest on periphery walls / partition on the wall angle of section 0.40 Mm thick gauge having equal flanges of 22 MM made from Precoated G.I.coil of length 3.0m. The entire grid system shall be designed to bear a distributed load of minimum 15 Kg/ Sq.M. (a) Storage and Handling precautions: 20. Metal ceiling tiles shall have be supplied in neatly packed cartons. 21. Not to store the cartons in flat and wet locations. 22. Handle cartons and individual tiles with care. 23. Do not drop or stand cartons or tiles or edges or corners. 24. Open cartons completely and using both hands with protective gloves, remove tiles in pairs with fair faces together. (b) Installation precautions: The following to be ensured before installation of the ceiling system. kk) The area is dry prior to ceiling installation work. ll) All wet trades are completed such as plastering, flooring etc. mm) Air conditioning duct work is completed nn) Electrical chasing or drawing lines etc. are in place. oo) No unauthorized weight is put on ceiling. Lighting fixtures to be suspended independently. pp) Metal ceiling Tiles should be installed by experienced contractors in compliance with manufactures specifications & conditions. qq) Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. rr) Metal ceiling tiles shall not be used to support any unauthorized loads. ss) Metal ceiling tiles shall be mechanically suspended properly & shall not be cemented nor glued to the surface of any other material. CUTOUTS FOR LIGHT AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: m) Metal Ceiling tiles are an Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). n) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. o) Acoustic Properties: The tiles offer an average NRC of 0.90 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The tiles are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES i) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. j) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. :006 ITEM SPECIFICATION FOR, WALL PANELLING Item: Providing & Fixing Wall Paneling with using 8 mm thick “ ANUTONE “ make magnesium oxide board with using G.I.Frame work with using G.I.Section of size – 0.55 thick having knuled web of 51.50 and two flanges of 26 mm each with lips of 10.50 mm and perimeter of 0.55 mm thick ( having one flanges of 20 mm & another flanges of 30 mm & a web of 27 mm ) Fixing at the distance of 0.30mm centre to centre with fixing magnesium board with help of self taped screw & finishing with jointing Fiber tape & using jointing compound with all material & Labor etc. completed Note: i) only wall panelling area will be measured for the purpose of payment. CODES & STANDARDS: The codes and standards generally applicable to the work of this section are listed hereinafter: BS-476–PART IV––MAGNISIUM OXIDE BOARD -INCOMBUSTIBILITY IS – 277 – 1982 – FOR GALVANIZING OF MS SHEETS The following clauses are intended to amplify the requirements of the reference documents listed above and the contractor shall comply with these clauses. Materials a) Frame work: G.I.Frame work with using G.I.Section of size – 0.55 thick having knuled web of 51.50 and two flanges of 26 mm each with lips of 10.50 mm and perimeter of 0.55 mm thick ( having one flanges of 20 mm & another flanges of 30 mm & a web of 27 mm ) Fixing at the distance of 0.30mm centre to centre. b) Wall panelling Board made from ,anutone make 8mm thick magnesium oxide board. FIXING THE G.I.SUSPENSION SYSTEM TO THE WALL PANELLING: G.I.Frame work with using G.I.Section of size – 0.55 thick having knuled web of 51.50 and two flanges of 26 mm each with lips of 10.50 mm and perimeter of 0.55 mm thick ( having one flanges of 20 mm & another flanges of 30 mm & a web of 27 mm ) Fixing at the distance of 0.30mm centre to centre. (a) Storage and Handling precautions: 25. Magnesium oxide board shall have be supplied in loose packing. 26. Not to store the cartons in flat and wet locations. (b) Installation precautions: The following to be ensured before installation of the wall paneling system. tt) The area is dry prior to ceiling installation work. uu) All wet trades are completed such as plastering, flooring etc. vv) Electrical chasing or drawing lines etc. are in place. ww) Magnasium oxide board should be installed by experienced contractors in compliance with manufactures specifications & conditions. xx) Installations shall be done in areas free from chemical fumes/ freezing temperatures and vibrations. CUTOUTS FOR LIGHT POINTS /SWITCH BOARD AND A/C FIXTURES: Rate quoted shall include the coast of making cut outs required for fixing light fixtures, air-conditioning diffusers, and fire detectors, etc. no extra payment shall be made for making cut- outs. FIRE RESISTANCE: p) Magnesium oxide board Incombustible material as per BS: 476 (Part- IV) and have been classified in class 1 for Spread of flame as per BS: 476 (Part VII) and class O for propagation as per BS: 476 (Part VI). q) Thermal properties: The Tiles have a low thermal conductivity of 0.43 W/ m0 KC. r) Acoustic Properties: The tiles offer an average NRC of 0.60 and a sound attenuation STA – 32 dB. EFFECT OF TEMPERATURE: The tiles are suitable for use in high temperature area due to their low heat conductivity. They can also be subjected to freezing temperatures without risk of damages. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. RATES k) The work shall be carried out as per above specification, drawings and as per direction of engineer – in –charge. l) The rate shall include the cost of all the materials, necessary openings for light fixtures, diffusers, machinery and manpower involved in all the operations described above including cartage, lifts and all taxes like, Sales Tax / VAT, Excise duty, octroi etc. as applicable. ITEM NO. :7 KOTA STONE :shall be chisel dressed and the top surface shall be machine polished with joints running true and parallel from side to side. Stones should be laid on a bed of cement or lime mortar. The pattern of the flooring shall be as per the Architects’/ Consultants’ drawing. Thickness of mortar bedding shall be as specified in the item specification. The stone slabs shall be thoroughly wetted with clean water. Neat cement shall be spread over the mortar bed and the slabs shall be placed one by one. Keeping in check the level and line of the flooring. The slabs are then gently tapped with wooden mallet till it is firmly and properly bedded. There should be no voids left. The joints should be not be more than 1mm thick. The joints should not smooth. If specification terrazzo filling of specified thickness shall be done in the joints between the kota stone slabs. The floor should be kept covered with damp sand or water for a week. Stone should be of sizes as specified. The stone shall be machine polished and than cleaned with oxalic acid. If the contractor is asked to mop the floor with kerosene and water by the engineer, the same be done without any extra cost. This shall be carried out daily at least for 10 times in 7 days. ITEM NO. :8 Granite Stone Slab : Granite shall be of approved colour and quality. The stone shall be hard, even, sound regular in shape and generally uniform in colour. It shall be without any soft veins, cracks of flows. The thickness of the stone shall be as specified in the items. All exposed face shall be double polished to tender truly smooth and the even reflecting surface. The exposed edges and corners shall be rounded off as directed. The exposed edges shall be machine cut and shall have uniform thickness. ITEM NO. :009 ALUMINUM FRAME DOOR: Providing, Fabricating and Erecting in position anodized (15 to 25 micron of desired color) door shutter (single or double action opening) of standard aluminum section from 18mm (3/4”) series of Jindal, Hindalgo, Domal or approved equivalent make of size top and vertical style 47.62 x 44.45 x 2mm ( w approx = 1.05 kg./m), lock rail and bottom section 114.30 x 44.45 x 2mm ( w approx = 1.83 kg/m), fitted on frame of size 101.60 x 44.45 x 2mm ( w app = 1.60 kg./m) with standard accessories like handle , stopper, locking arrangement, C.P. brass hinges, etc, and glazing of 5 mm and above thick float glass of Modi or approved equivalent or bajari (frosted) glass, bottom pan of compact sheet of Vir laminate or equivalent fixed with rubber / PVC beading in upper and lower panel complete. Including all allied, appropriate sections (members) and hardware as required by site condition and prescribed by manufacturer. Materials : Jindal, Hindalgo, Domal or approved equivalent make of size top and vertical style 47.62 x 44.45 x 2mm ( w approx = 1.05 kg./m), lock rail and bottom section 114.30 x 44.45 x 2mm ( w approx = 1.83 kg/m), fitted on frame of size 101.60 x 44.45 x 2mm ( w app = 1.60 kg./m) with standard accessories like handle , stopper, locking arrangement, C.P. brass hinges, etc, and glazing of 5 mm and above thick float glass of Modi or approved equivalent or bajari (frosted) glass, bottom pan of compact sheet of Vir laminate or equivalent fixed with rubber / PVC beading in upper and lower panel complete. Workmanship : The outer frame shall be fix by screw and wooden plugs in masonary of RCC structure as directed necessary touching work with cement mortar shall be done to the structure and making good the same without claming any extra cost.All section joint shall be fixed with 25x25x3mm angle section with sheet metal pan head screw of full htread.Fixing of glass/5mm thick compact sheet shall be done with glazing clip.The whole shall be in true line and level and up to full satisfaction of engineer- in –charge. Mode of measurement & Payment : The rate shall be for all materials and labour for completion of work satisfactory. The rate shall be for a unit of one square meter. Measurement shall be taken for wall to wall and door , window and column deducted as per site condition. ITEM NO. :010 DOOR CLOSER Providing and fixing hydraulic door closer of approved size and made such as EVERITE / HYPER / EGL/GODREG or equivalent as directed. all lift, level and leads. Hydraulic Door Closures of approved design and make including the accessories supplied by the Company along with it. All fixtures, fastenings including C.P. Brass screws are included. Fixing of the door closure should be done as per guidance of the supplier, by the experienced artisan approved by them. Rate includes cost of all materials associated with the approved fixture, and all labour for fixing the same inclusive of removal and refitting of shutters of the existing doors, adjustment of plumb and level of the frame, minor repair to the frame if required, etc. Mode of measurement: The fixtures are measured in numbers. ITEM NO. :011 & 12 ALUMINUM FIX WINDOW, PARTITION AND VENTS: Providing, fabricating and erecting in position anodized (15 to 25 micron of desired color) aluminum fixed glass windows / louvers/ partition /vents for toilets, basement etc. made up from standard aluminum section of Jindal, Hindalco, Domal or approved equivalent make from 18mm (3/4“) series of Jindal or approved equivalent make of size 47.62 x 44.45 x 2mm (w app = 1.05 Kg/m), or of size 64 x 40 x 2 mm ( w app = 1.09 Kg./m) with all standard accessories and glazing of 5mm or required thickness of float glass or bajari (frosted) glass or wired glass of Modi or approved equivalent , fixed with aluminum beading etc. complete as per details including all fittings and fixtures & locking arrangement completes. partition with full or bottom pan of compact sheet of vir laminate or equivalent/ prelaminated board fixed with rubber / PVC beading in upper and lower panel complete. Partition can be with part or full glass in with rubber / PVC beading in upper and lower panel complete as per architects detail Including all allied, appropriate sections (members) and hardware as required by site condition and prescribed by manufacturer. Materials : Jindal, Hindalco, Domal or approved equivalent make from 18mm (3/4“) series of Jindal or approved equivalent make of size 47.62 x 44.45 x 2mm (w app = 1.05 Kg/m), or of size 64 x 40 x 2 mm ( w app = 1.09 Kg./m) with all standard accessories and glazing of 5mm or required thickness of float glass or bajari (frosted) glass or wired glass of Modi or approved equivalent , fixed with aluminum beading etc. complete as per details including all fittings and fixtures & locking arrangement completes. partition with full or bottom pan of compact sheet of vir laminate or equivalent fixed with rubber / PVC beading in upper and lower panel complete. Partition can be with part or full glass in with rubber / PVC beading in upper and lower panel complete. Workmanship : The outer frame shall be fix by screw and wooden plugs in masonry of RCC structure as directed necessary touching work with cement mortar shall be done to the structure and making good the same without claiming any extra cost. All section joint shall be fixed with 25x25x3mm angle section with sheet metal pan head screw of full thread. Fixing of glass/5mm thick compact sheet shall be done with glazing clip. The whole shall be in true line and level and up to full satisfaction of engineer- in –charge. Mode of measurement & Payment : The rate shall be for all materials and labour for completion of work satisfactory. The rate shall be for a unit of one square meter. Measurement shall be taken for wall to wall and door , window and column deducted as per site condition. ITEM NO. :0013 Rate for Refixing of Aluminium section used previously, by setting it as new dimensions. Rate incl.of cutting the section, fixing it at suitable position incl.fixtures such as angles, screws,rubber patti,etc.comp.as directed MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. ITEM NO. :0014 Labour changes for removing of Alum.Door / Partition / Alum. Windo / M.S. Grill etc. MEASUREMENTS The measurement shall be taken in square meter and the length and breath shall be measured in Cm correct to two decimal places. ITEM NO. :0015 Repairing of existing Alluminium windows/vents. Rate inclusive of removing the windows/vents from its position and repairing it by adding additional Alluminium section pipe as required, so as to make arrangement for fixing exhaust fan ,etc., and again fittinf it to its required position. Rate incl. of all materials and labours required to make good the same as per instruction of engg. incharge/Architect Consultant. Mode of measurement: The fixtures are measured in numbers. ITEM NO. :016,17 WASH BASIN :Providing and fixing wash basin with single hole for pillar top white C.I. or M.S. brackets painted white intruding cutting holes, and making good the same but excluding fittings, vetreous china flat back wash basin 550 mm. x 400 mm. in white colour. 1.0. Materials: 1.1. The white glazed earthenware wash basin shall be 550 cm. x 400 mm. of 1st quality and make as approved by the Engineer-in-charge. The wash basin shall conform to M-59. 2.0. Workmanship : 2.1. The wash basin shall be fixed on the wall as and where directed. The wash basin shall be supported on a pair of M.S. or C.I. brackets fixed in C.M. 1 : 3 (1 cement: 3 sand). The bracket shall conform to I. S.: 775-1962. The wall plaster on the rear shall be cut to rest the top edge of the wash basin. After fixing the basin, plaster shall be made good and surface finished to match with the existing one. 2.2. The bracket shall be painted white with ready-mixed paint. 2.3.The C.I. brass trap and union shall be connected to 32 mm. dia. waste pipe which shall be suitably bent towards the wall and which shall discharge into an open drain leading to a gully trap or direct into the gully-trap on the ground floor and shall be connected to a waste pipe through a floor trap-on the upper floors. C.P. brass trap and union may not be provided where the surface drain or a floor trap is placed directly under the basin and the waste is discharged into vertically. 2.4. The height of the front edge of the wash basin from the floor level shall be 80 cms. ITEM NO. :0018 PVC PIPES (A) Providing and supplying of standard lengths BIS marked rigid unplasticised PVC (UPVC) pipes with approved quality and brand of solvent cement coupler joints (including cost of solvent cement and one coupler with each pipe), conforming to IS:4985 (Latest edition) including of freight, loading, unloading, stacking etc.complete. (1) 160 mm diameter pipe (OD) having test pressure of 4 Kg/cm2 (2) 50 mm diameter pipe (OD) having test pressure of 4 Kg/cm2 D.8.5.1 General The pipes shall conform to IS-4985-1988 or the latest edition of IS codes for unplaticized P.V.C. pipes for potable water supplies with BIS marks on each pipe. The make of PVC pipe shall be any one of the following. (1) Finolex (2) Dutron (3) Supreme The details given below briefly cover the requirements for dimensions and tests for unplasticized P.V.C. pipes. D.8.5.2 Composition The materials from which the pipe is produced shall consists substantially of virgin polyvinyl chloride to which may be added only those additives that are needed to facilitate the manufacture of sound pipe of good surface finish, mechanical strength and capacity under conditions of use. No other rework material shall be used. D.8.5.3 Dimensions The outside diameter, the tolerance outside diameter and wall thickness of pipe shall be as per IS 4985 (Table No.1). D.8.5.4 Classification of Pipes The pipes shall be suitable for the maximum test pressure of 4 Kg/cm2. D.8.5.5 Supply of Pipes, Couplers, Fittings, Solvent Cement • The pipes shall be supplied in straight lengths of 4, 5 & 6 meters with a tolerance of (+)16 mm and (-) 0 mm. • The injection moulded couplers, specials, fittings etc. of relative diameter shall be supplied as per the requirement along with the pipe at no extra cost. • The solvent cement of approved mark and manufacturer shall be supplied as per standard consumption for each coupler joint, as well as for specials fittings etc. as directed by the Engineer. • All the PVC pipes, couplers, fittings, specials shall be staked in a closed store so as to protect them against ultra violet rays from sun as well as frequent changes in temperature. D.8.5.6 Marking Each pipe, coupler, specials, fittings etc. shall be indelibly marked at internal of not more than 3 meters in colour as indicated in Clause No. 10.1.1 of IS. The marking shall show the followings:a) The manufacturer’s name or trade mark. b) Outside diameter c) Maximum working pressure, batch number d) BIS certification marking. (B) Lowering, laying and jointing PVC pipes and specials of following class and diameter except cost of PVC pipes and cement solvent, giving satisfactory hydraulic testing as per ISI Code, etc complete. • The excavation for trenches will be done before laying of the pipes as per required depth and width so that adequate space can be made available for joint. • Before laying, the pipes shall be brushed through out the length so that the dust and soil can be removed. • All the specials such as bends, tees, reducer, etc shall be fixed as per instruction of engineer in charge in the pipeline. • The pipe shall be hydraulically tested during the testing & no leakage shall be observed. If, leakage is observed, it will be set rightly by the contractor at his own cost as per the instruction of engineer in charge. 30% payment shall be made after hydraulic testing of pipeline.The scope for the item cover:Cost of additional excavation required for jointing clearing the site of all scrubs, bushes and trees and dewatering where necessary.Labour for laying pipes in trenches to correct alignment at required depth with tools, including cutting of pipes and specials if required for laying of pipes including connecting pipes to specials and ppurtenances. Cost of the scaffolding, tools and plants, ropes etc.Protection of existing works from damage and cost or repair to the damages carried out to the existing structure, sewer line telephone/electricity cables, electric cables,electric lines, gas pipe line, irrigation pipeline etc.Labour for making joints including material for joints, tools as well as tests. Testing of pipes for leakage under water pressure and flushing the pipes after testing and construction work shall have to be arranged by the contractor at his own cost. Method of measurement and payment: The measurement shall be recorded in running meter of pipe length laid along the centerline of axis of pipeline for consolidated activities (a) & (b) including pipe material & specials if required. No payment shall be made for overlaps etc. 30% payment of this item shall be with held for satisfactory hydraulic testing. The payment shall be made on running meter basis as per relevant item of Schedule B of the tender. ITEM NO. :19 UPVC PIPES AND FITTINGS : The pipes shall be round and shall be supplied in straight lengths with socketed ends. The internal and external surfaces of pipes shall be smooth, clean, and free from grooving and other defects. The ends shall be cleanly cut and square with the axis of the pipe. The pipes shall be designated by external diameter and shall conform to IS:4985-1981. Fittings: Fittings shall be of the same make as that of pipes, injection moulded and shall conform to Indian Standard. 3.3.6.2 Laying and Jointing: The pipes shall be laid and clamped to wooden plugs fixed above the surface of the wall. Alternatively plastic clamps of suitable designs shall be preferred. Provision shall be made for the effect of thermal movement by not gripping or disturbing the pipe at supports between the anchors for suspended pipes. The supports shall allow the repeated movements to take place without abrasion. Jointing for UPVC pipes shall be made by means of solvent cement for horizontal lines and `O’ rubber ring for vertical line. The type of joint shall be used as per site conditions/direction of the Client’s Representative. Where UPVC pipes are to be used for rain water pipes, the pipe shall be finished with G.I. adopt er for insertion in the R.C.C. slab for a water proof joint complete as directed by Client’s Representative. 3.3.6.3 Supports: UPVC pipes require supports at close intervals. Recommended support spacing for unplasticised PVC pipes is 1400 mm for pipes 50 mm dia and above. Pipes shall be aligned properly before fixing them on the wooden plugs with clamps. Even if the wooden plugs are fixed using a plumb line, pipe shall also be checked for its alignment before clamping, piping shall be properly supported on, or suspended from clamps, hangers as specified and as required. The Contractor shall adequately design all the brackets, saddles, anchors, clamps and hangers and be responsible for their structural sufficiency. Pipe supports shall be primer coated with rust preventive paint. 3.3.6.4 Repairs: While temporary or emergency repairs may be made to the damaged pipes, permanent repairs should be made by replacement of the damaged section. If any split or chip out occurs in the wall of the pipe, a short piece of pipe of sufficient length to cover the damaged portion of the pipe is cut. The sleeve is cut longitudinally and heated sufficiently to soften it so that it may be slipped over the damaged hard pipe. 3.3.6.5 Testing: All lengths of PVC rain water pipes shall be fully tested for water tightness by means of water test maintained for not less than 30 minutes. All pipes shall be subjected to a test pressure of at least 1.5 meter head of water head. The test pressure shall, however, not exceed 6 meter head at any point. The pipes shall be plugged preferably with standard design plugs with rubber plugs on both ends. The upper end shall, however, be connected to a pipe for filling with water and getting the required head. ITEM NO. :20 RIGID PVC PIPES AND FITTINGS : The pipes shall be round and shall be supplied in straight lengths with socketed ends. The internal and external surfaces of pipes shall be smooth, clean, and free from grooving and other defects. The ends shall be cleanly cut and square with the axis of the pipe. The pipes shall be designated by external diameter. Fittings: Fittings shall be of the same make as that of pipes, injection moulded and shall conform to Indian Standard. Laying and Jointing: The pipes shall be laid and clamped to wooden plugs fixed above the surface of the wall. Alternatively plastic clamps of suitable designs shall be preferred. Provision shall be made for the effect of thermal movement by not gripping or disturbing the pipe at supports between the anchors for suspended pipes. The supports shall allow the repeated movements to take place without abrasion. Jointing for RPVC pipes shall be made by means of solvent cement for horizontal lines and `O’ rubber ring for vertical line. The type of joint shall be used as per site conditions/direction of the Client’s Representative. Where RPVC pipes are to be used for rain water pipes, the pipe shall be finished with G.I. adopter for insertion in the R.C.C. slab for a water proof joint complete as directed by Client’s Representative. Supports: RPVC pipes require supports at close intervals. Recommended support spacing for RPVC pipes is 1400 mm for pipes 50 mm dia and above. Pipes shall be aligned properly before fixing them on the wooden plugs with clamps. Even if the wooden plugs are fixed using a plumb line, pipe shall also be checked for its alignment before clamping, piping shall be properly supported on, or suspended from clamps, hangers as specified and as required. The Contractor shall adequately design all the brackets, saddles, anchors, clamps and hangers and be responsible for their structural sufficiency. Pipe supports shall be primer coated with rust preventive paint. Repairs: While temporary or emergency repairs may be made to the damaged pipes, permanent repairs should be made by replacement of the damaged section. If any split or chip out occurs in the wall of the pipe, a short piece of pipe of sufficient length to cover the damaged portion of the pipe is cut. The sleeve is cut longitudinally and heated sufficiently to soften it so that it may be slipped over the damaged hard pipe. Testing: All lengths of PVC rain water pipes shall be fully tested for water tightness by means of water test maintained for not less than 30 minutes. All pipes shall be subjected to a test pressure of at least 1.5 meter head of water head. The test pressure shall, however, not exceed 6 meter head at any point. The pipes shall be plugged preferably with standard design plugs with rubber plugs on both ends. The upper end shall, however, be connected to a pipe for filling with water and getting the required head. ITEM NO. :0021 PVC VENTILTILATING COWL: Providing and fixing in position PVC Ventilating cowl to pipes. Mode of measurement: The fixtures are measured in numbers. ITEM NO. :0022 PIPE CLAMPS (system to support/clamp all type of pipes on wall or suspend it from ceiling): Providing and fixing 'Shaivi' brand heavy duty, electroplated MS (6mm thick) 'L' bends of different sizes as required per site condition with slotted FRP channel of 3.5mm thick with necessary accessories like nut bolt, washer set, EPDM rubber mounted 'U' bolt along with 1.5mm washer and nut, stud with anchor fastener for vertical suspenders under ceiling. Product and accessories to be customized in length as per site condition. Price included making of necessary arrangements and cleaning on site to fix the system. ITEM NO. :23 GLASS FILMS: Providing and fixing sun control/ frosted glass film: Technical details of the work are as under. Thickness : 1.5 micron/ 2 micron Visible light transmission : 40 to 50 % UV ray rejection : 99% Heat rejection : 40 to 50% Mode of measurement: Length and breath of clear opening of windows shall be measured and paid in sq. mt. units. ITEM NO. :0024 Providing 20 gauge Stainless steel 304 grade plates with vinyl stickers cut and pasted in various size in any language. ITEM NO. :0025 Fixing any size S.S. name plates in bk./concrete/Alluminium any base with screws and necessary accessories at any height and level. ITEM NO. :0026 Providing 2.0 mm th. acrylic sheet in blue background and white letters. The sheet shall be made as per sizes required, as direc. by engg. in charge. ITEM NO. :0027 ACRYLIC NAME PLATES Providing and fixing signage on 3 mm acrylic sheet of approved make and shade and size with LG make vinyl sticker type lettering complete as per architectural drawing. Rate includes cost of all materials, including steel, connectors, welding, primer, paint and all labor for fabrication, transportation and erection etc. are included. Mode of measurement: Payment is done in square mt. ITEM NO. :0028,29 GLASS AND GLAZING 1). SCOPE The work covered by this specification consists furnishing and installing of all glass for Doors, Windows, Ventilators. etc. complete and in strict accordance with specification and applicable drawings. in and the 2). GENERAL The work mentioned in this section shall be measured separately only in cases where it is specified so, distinctly in the schedule of quantities. The sizes of the glass if indicated on the drawings are approximate. The actual sizes required shall be determined by measuring the frames to receive the glass. The thickness of the glass shall be as given in the technical specification for materials, under the title ‘Glass’. Glazing to steel, doors and windows shall be done in compliance with the suppliers instructions, using the clips and the beads supplied. Glass panes shall be mixed in position only after the steel or wood work has received a primer coat and one of the finishes coats of point. Frosted glass panel shall be fixed with the frosted face inside. Care shall be taken that water does not pass through the putty used for fixing the glass. Glass in wooden/steel doors and windows shall be kept in position only after fixing putty at its back. A thin layer of putty shall be provided between the glass panes and the beading and also between the steel or woodwork and the glass, such that no voids are left in the joints. Broken glass prior to acceptance shall be neatly removed and replaced at the contractor's expenses. Edges of glass louvers shall be ground and left free of any sharp edges. Glass shall be protected against any damage. After inspection any labels, paint, smear and spots shall be removed from the glass and the glass shall be washed clean. 3). SAMPLES The contractor shall submit for approval, four samples of all material specified under the specification. ITEM NO. :0030 MIRROR WITH GHANA TEAK WOOD FRAME The teak wood (Ghana or equivalent) shall be of good quality as required for the item to be executed.Teak wood (Ghana or equivalent) generally br free from large, loose, dead or cluster knots, flaws, shakes, warps, twists bends, or any other defects. It shall generally be uniform in substance and of straight fibres as far as possible. It shall be free form rot, decay, harmful fungi and other defects of harmful nature which affect the strength durability of its usefulness for purpose for which it is required. The colour shall be uniform as far as possible. Any effort like painting, using any adhesive or resin materials made to hide the defects shall render the pieces liable to rejection by the Clerk- Of- Work or Engineer-inCharge 4mm thick hardboard shall be used back side for support to mirror. Mirror shall be modi or saint gobain or equivalent 5mm thick. All Scantlings, planks etc. shall be sawn in straight lines and planes in the direction of grains and of uniform thickness. The tolerances in the dimensions shall be allowed at the rate of 1.00mm per face to be planed. Second class teak wood shall have no individual hard and sound knots shall be more than 15 sq. cms. In size and aggregate area of such knots shall not exceed 2 % of the area