TRULOK SUSPENSION SYSTEMS COMPONENTS AND ASSEMBLIES T1 EXPOSED GRID-PRELUDE 24 AND 15 LAYOUT OPTIONS T2 PRELUDE 24 STITCHED EXPOSED GRID SECTIONS T3 PRELUDE 15 STITCHED EXPOSED GRID SECTIONS T16 SL2 OR K2C2 PLANKS SPANNING BETWEEN CONTINUOUS LIGHTING TRUNKING T4 PRELUDE 24 TL SHOWING CONNECTION AND EXPANSION UNDER CONDITIONS OF FIRE T17 SLOTTED AND UNSLOTTED BANDRASTER ASSEMBLIES FOR SL2 OR BOARD PLANK SYSTEMS T5 PRELUDE 24 XL SHOWING CONNECTION AND EXPANSION UNDER CONDITIONS OF FIRE T18 BANDRASTER TARTAN GRID USING 90 CONNECTORS OR CROSSING ELEMENTS T6 ALTERNATIVE HANGER METHODS T19 BANDRASTER GRID CONNECTIONS T7 SUGGESTED ALTERNATIVE SOFFIT FIXINGS T8 ALTERNATIVE PERIMETER OPTIONS T20 SLOPING UPSTAND CHANGE OF LEVEL AND SLOPING CEILING TO WALL T9 PRELUDE 24 WITH 600 X 600 PANELS T10 PRELUDE15 WITH 600 X 600 PANELS T11 ATTACHMENTS FOR TRULOK PRELUDE 24 AND 15 EXPOSED GRIDS T12 TYPICAL PARTITION HEAD FIXINGS USING TRULOK FIXING CLIPS T13 PARTITION HEAD FIXINGS USING CLIPS FOR PRELUDE 15 AND SILHOUETTE XL T14 SEMI-CONCEALED SYSTEMS WITH SL2 LONG SPAN PANELS T15 GRID CONSTRUCTION FOR 300 x 1500 AND 300 x 1800 SL2 OR K2C2 PLANKS O T21 VERTICAL UPSTAND OR BULKHEAD USING 'F' SECTION TRIM T22 VERTICAL UPSTAND OR BULKHEAD USING 'F' UPSTAND TRIMS TO PROVIDE UPSTAND DEMOUNTABILITY T23 VERTICAL UPSTAND FOR TRULOK PRELUDE 24 AND 15 SUITABLE FOR UP TO 600mm HEIGHT T24 ALTERNATIVE VERTICAL UPSTAND FOR TRULOK PRELUDE 24 AND 15 SUITABLE FOR 600mm OR LESS T25 FLOATING CEILING EDGE DETAIL T26 SILHOUETTE XL END CONNECTIONS AND PERIMETER DETAILS The designs and layouts shown are typical and not definitive. Users should verify that their proposed installations are suitable for the intended purpose. Armstrong are continuously developing their ceiling systems. It is therefore recommended that you contact our Internal Technical Sales (Tel : FREEPHONE 0800 371 849) whenever you are considering ceiling specifications. This will help to ensure correct suspension system components are specified and used. 11/98 Fig 1. Fig 2. FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE Fig 3. 600 X 1200 MODULES Fig 1. (Preferred layout) Layout for 600 x 1200 panels parallel to Cross Tee. Main Runners at 1200 centres with 1200 Cross Tees spanning at 600 centres. Fig 2. Layout for 600 x 1200 panels parallel to Main Runner. Main Runners at 600 centres with 600 Cross Tees spanning at 1200 centres. Recommended for Ceramaguard Fig 3. Layout for 600 x 1200 panels parallel to Main Runner. Main Runners at 1200 centres with 1200 Cross Tees spanning at 1200 centres and supporting additional 1200 Cross Tees parallel to Main Runner. 1200 600 600 1200 1200 600 Fig 4. 1200 Fig 5. 600 600 Fig 6. 600 X 600 MODULES 1250 600 600 1250 1200 600 600 ARMSTRONG TRULOK SUSPENSION SYSTEMS 600 1000 EXPOSED GRID PRELUDE 24 AND 15 LAYOUT OPTIONS 500 500 500 X 500 MODULES Fig 6. Layout for 500 x 500 panels Main Runners at 1000 centres with 1000 Cross Tees at 500 centres and 500 Cross Tees at mid-points of 1000 Cross Tees. NOTE: Hangers at 1250 centres along Main Runners. THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T1 SYMBOL INDICATES THE POSITION OF VERTICAL HANGERS. Fig 4. (Preferred layout) Layout for 600 x 600 panels Main Runners at 1200 centres with 1200 Cross Tees spanning at 600 centres and supporting additional 600 Cross Tees at mid-points of 1200 Cross Tees. Fig 5. Alternative layout for 600 x 600. Main Runners at 600 centres with 600 Cross Tees spanning at 600 centres. Recommended for Ceramaguard 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 6 6 10 10 38 Fig 1. UNIVERSAL MAIN RUNNER 38 Fig 2. TL HOOK CROSS TEE 24 24 6 6 6 10 2 2 35 30 25 ARMSTRONG TRULOK SUSPENSION SYSTEMS 24 24 T2 Fig 3. XL STAB CROSS TEE 24 PRELUDE 24 STITCHED EXPOSED GRID SECTIONS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 6 6 10 10 38 Fig 1. UNIVERSAL MAIN RUNNER 38 Fig 2. TL HOOK CROSS TEE 15 15 6 10 38 ARMSTRONG TRULOK SUSPENSION SYSTEMS T3 Fig 3. XL STAB CROSS TEE 15 PRELUDE 15 STITCHED EXPOSED GRID SECTIONS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE UNIVERSAL MAIN RUNNER EXPANSION DETAIL ARMSTRONG TRULOK SUSPENSION SYSTEMS TL CROSS TEES UNDER EXPANSION PRELUDE 24 TL SHOWING CONNECTION AND EXPANSION UNDER CONDITIONS OF FIRE THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T4 UNIVERSAL MAIN RUNNER UNDER EXPANSION TL CROSS TEES LOCATED IN MAIN RUNNER 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE UNIVERSAL MAIN RUNNER EXPANSION DETAIL ARMSTRONG TRULOK SUSPENSION SYSTEMS XL CROSS TEES UNDER EXPANSION PRELUDE 24 XL SHOWING CONNECTION AND EXPANSION UNDER CONDITIONS OF FIRE THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T5 UNIVERSAL MAIN RUNNER UNDER EXPANSION XL CROSS TEES LOCATED IN MAIN RUNNER 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE Fig 1. Fig 1. 2mm SUSPENSION WIRE Fig 2. 19mm x 19mm SUSPENSION ANGLE Fig 2. Fig 3. M6 THREADED WIRE ROD WITH SUSPENSION CLIP Fig 4. QUICK HANGER Fig 3. Fig 5. ADJUSTABLE SUSPENSION HANGER Fig 6. NONIUS HANGER Fig 4. Fig 5. Fig 6. T6 ARMSTRONG TRULOK SUSPENSION SYSTEMS ALTERNATIVE HANGER METHODS (SEE T7 FOR SOFFIT FIXINGS) THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE CUT Fig 1. 2mm SUSPENSION WIRE AND ANGLE BRACKET Fig 2. 19mm x 19mm SUSPENSION ANGLE Fig 3. M6 THREADED ROD WITH SOFFIT INSERT Fig 4. QUICK HANGER AND SCREW EYE Fig 1. Fig 5. ADJUSTABLE SUSPENSION HANGER AND ANGLE BRACKET METHOD OF FORMING SOFFIT FIXING Fig 6. NONIUS HANGER TO TIMBER JOIST OR SOFFIT FIXING Fig 2. THREADED SOFFIT INSERT SCREW EYE IN SOFFIT Fig 3. Fig 4. SOFFIT FIXING Fig 6. ARMSTRONG TRULOK SUSPENSION SYSTEMS SUGGESTED ALTERNATIVE SOFFIT FIXINGS (SEE T6 FOR CORRESPONDING HANGER METHODS) THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T7 Fig 5. 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 32 24 32 7.5 19 24 44 15 24 16 33 WALL ANGLE WALL ANGLE UNEQUAL U PROFILE 'F' UPSTAND 25 25 40 32 8 15 19 ARMSTRONG TRULOK SUSPENSION SYSTEMS 15 15 20 CHANNEL TO TIMBER GROUND MICROLOOK SHADOWLINE ALTERNATIVE PERIMETER OPTIONS TEGULAR SHADOWLINE THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES A8 T8 ANGLE TO TIMBER GROUND 15 6.5 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 1200 MAX CENTRES FOR SUSPENSION Layout for 600 x 600 panels Main Runners at 1200 centres with 1200 Cross Tees spanning at 600 centres and 600 Cross Tees at mid points of 1200 Cross Tees 600 MAX 600 MAX PERIMETER TRIM ARMSTRONG BOARD EDGE PANELS ON PRELUDE 24 EXPOSED GRID ARMSTRONG TRULOK SUSPENSION SYSTEMS PRELUDE 24 WITH 600 X 600 PANELS (1200mm AND 600mm CROSS TEES) THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T9 ARMSTRONG TEGULAR EDGE PANELS ON PRELUDE 24 EXPOSED GRID 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 1200 MAX CENTRES FOR SUSPENSION Layout for 600 x 600 panels Main Runners at 1200 centres with 1200 Cross Tees spanning at 600 centres and 600 Cross Tees at mid points of 1200 Cross Tees 600 MAX 600 MAX PERIMETER TRIM ARMSTRONG MICROLOOK EDGE TILE ON PRELUDE 15 EXPOSED GRID ARMSTRONG TRULOK SUSPENSION SYSTEMS PRELUDE15 WITH 600 X 600 PANELS (1200mm and 600mm CROSS TEES) THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T10 ARMSTRONG FEATURE EDGE DETAILS ON PRELUDE 15 EXPOSED GRID 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE ARMSTRONG TRULOK SUSPENSION SYSTEMS ATTACHMENTS FOR PRELUDE 24 AND 15 EXPOSED GRIDS WHITE PAINTED 4-CLAW (2 PIECE) CLIP FOR USE WITH PRELUDE 24 GRID SYSTEMS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T11 WHITE PAINTED 2-CLAW CLIP FOR USE WITH PRELUDE 15 GRID SYSTEMS 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE BRACING TO BE DETERMINED BY OTHERS NB.1. The drawings on this page show 4-claw fixing clips used with the Prelude 24 (24mm) exposed system. Partitions may also be attached to the Prelude 15 (15mm) exposed systems by using the 2-claw clip shown on sheet T11. NB.2. Types and loads of Partitioning can vary considerably. The advice of a structural engineer may be necessary to determine bracing requirements. T12 ARMSTRONG TRULOK SUSPENSION SYSTEMS TYPICAL PARTITION HEAD FIXINGS USING TRULOK FIXING CLIPS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE Fig 1. Partition Clip for Trulok Silhouette XL Grid Sections. Fig 2. Partition Clip for Prelude 24 and 15 Grid Sections. ARMSTRONG TRULOK SUSPENSION SYSTEMS T13 Fig 1. Fig 2. PARTITION HEAD FIXINGS USING CLIPS FOR PRELUDE 24 AND 15 AND SILHOUETTE XL THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE SL2 A A SECTION A-A 1200mm LONG PLANKS SUPPORTED BY 20.5mm DEEP Z SECTIONS CUT TO LENGTH B B D D F F SECTION B-B 1200 SL2 C C SECTION C-C 1500mm OR 1800mm LONG PLANKS SUPPORTED BY 32mm DEEP Z SECTIONS SECTION D-D 1500 OR 1800 SL2 E E ARMSTRONG TRULOK SUSPENSION SYSTEMS SECTION F-F SEMI-CONCEALED SYSTEMS WITH SL2 LONG SPAN PANELS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T14 2000 SECTION E-E >or= 2000mm LONG PLANKS SUPPORTED BY DOUBLE HEIGHT Z SECTIONS FIXED TO PRIMARY GRID 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE HANGER CENTRES AT 1200mm MAX MAIN RUNNERS AT 1500 mm OR 1800mm CENTRES ARMSTRONG TRULOK SUSPENSION SYSTEMS T15 32mm DEEP 'Z' SECTION SPACER BARS AT MAXIMUM 1800mm CENTRES PERIMETER SPACER BAR FIXED TO WALL GRID CONSTRUCTION FOR 300 x 1500 AND 300 x 1800 SL2 OR K2C2 PLANKS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE HANGER CENTRES AT 1200mm MAX B B A PRELUDE 24 UNIVERSAL MAIN RUNNER SECTION A-A A SIZE AND TYPE OF 'Z' SECTION DEPENDS ON SIZE OF PLANKS SECTION B-B ARMSTRONG TRULOK SUSPENSION SYSTEMS SL2 OR K2C2 PLANKS SPANNING BETWEEN CONTINUOUS LIGHTING TRUNKING NOTE: LUMINAIRES ARE SUPPORTED INDEPENDENTLY OF THE GRID THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T16 SPACER BARS AT 1800mm CENTRES ALONG MAIN RUNNERS 1198 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE UNSLOTTED 'Z' SECTION SLOTTED 1200mm HANGER CENTRES A 7.5 10 B SECTION ARMSTRONG TRULOK SUSPENSION SYSTEMS B 25 50 50 75 75 100 100 125 T17 35 A PRELUDE 24 CROSS TEES SLOTTED AND UNSLOTTED BANDRASTER ASSEMBLIES FOR SL2 OR BOARD PLANK SYSTEMS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE HANGER CENTRES DEPENDENT ON MODULE SIZE 'Z' SECTION OR TEE BAR TO CHOICE CROSSING ELEMENT MODULE SIZE TO CHOICE T18 90O CONNECTOR ARMSTRONG TRULOK SUSPENSION SYSTEMS BANDRASTER TARTAN GRID USING 90O CONNECTORS OR CROSSING ELEMENTS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE Fig 1. WALL CONNECTOR. Fig 2. SPLICE Fig 3. CROSSING ELEMENT Fig 4. 90O CONNECTOR Fig 1. Fig 3. T19 Fig 2. Fig 4. ARMSTRONG TRULOK SUSPENSION SYSTEMS BANDRASTER GRID CONNECTIONS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 1198 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 19 x19 CROSS BRACE SOFFIT ANGLE BRACKET 19 x 19 SUSPENSION ANGLES 13 x 38 x 13 SUSPENSION CHANNEL 450 MAX BRACE HANGERS MAIN RUNNER MAIN RUNNER 600 MAX A UNEQUAL 'U' PROFILE AT WALL ISOMETRIC AT A ARMSTRONG TRULOK SUSPENSION SYSTEMS SLOPING UPSTAND CHANGE OF LEVEL AND SLOPING CEILING TO WALL THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T20 'F' UPSTAND FIXED TO SUSPENSION CHANNEL 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE SOFFIT ANGLE BRACKET 600 MAX 13 x 38 x13 SUSPENSION CHANNEL 20 x 40 x 20 CHANNEL TRIM 19 x19 CROSS BRACE 600 MAX BUILDING BOARD BY OTHERS A T21 'F' UPSTAND FIXED TO SUSPENSION CHANNEL ISOMETRIC AT A ARMSTRONG TRULOK SUSPENSION SYSTEMS VERTICAL UPSTAND OR BULKHEAD USING 'F' SECTION TRIM THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE SOFFIT ANGLE BRACKET 600 MAX 19 x19 ANGLE 19 x19 SUSPENSION ANGLE 'F' UPSTAND SECTION 19 x19 CROSS BRACE BUILDING BOARD BY OTHERS 600 MAX 'F' UPSTAND SECTION T22 'F' UPSTAND FIXED TO MAIN TEES BY SELF TAPPING SCREWS TO PROVIDE UPSTAND DEMOUNTABILITY ARMSTRONG TRULOK SUSPENSION SYSTEMS VERTICAL UPSTAND OR BULKHEAD USING 'F' UPSTAND TRIMS TO PROVIDE UPSTAND DEMOUNTABILITY THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 1198 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE CONTINUOUS 19 x 32 ANGLE LOCKING HOLD DOWN CLIP TO RETAIN VERTICAL PANEL 19 x 32 ANGLE TRIM MAIN RUNNER NOTCHED TO FORM 90o CROSS TEE WIRE TIE 19 x 32 ANGLE TRIM ARMSTRONG TRULOK SUSPENSION SYSTEMS VERTICAL UPSTAND FOR PRELUDE 24 AND 15 SUITABLE FOR UP TO 600mm HEIGHT THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T23 MAIN RUNNER 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 250 19 x 32 PAINTED ANGLE 250 19 x 19 SUSPENSION ANGLE LOCKING HOLD DOWN CLIP TO RETAIN VERTICAL PANEL MAIN RUNNER NOTCHED TO FORM 90o CROSS TEE WIRE TIE 19 x 32 ANGLE TRIM ARMSTRONG TRULOK SUSPENSION SYSTEMS ALTERNATIVE VERTICAL UPSTAND FOR PRELUDE 24 AND 15 SUITABLE FOR UP TO 600mm HEIGHT THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T24 MAIN RUNNER 11/98 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 19 x 19 SUSPENSION ANGLE FIXED TO MAIN RUNNER AT CENTRES NOT GREATER THAN 450 mm FROM PERIMETER CR0SS TEES BRACED BY 19 x 19 ANGLE AND FIXED TO PERIMETER CHANNEL AT 1200 C/S MAIN RUNNER CEILING TILE 20 x 40 x 20 PAINTED CHANNEL CLEATED TO MAIN RUNNER AND CROSS TEES BY ANGLE BRACKETS T25 ARMSTRONG TRULOK SUSPENSION SYSTEMS FLOATING CEILING EDGE DETAIL THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES 11/98 6 FOR ITEM NUMBERS SEE TRULOK SUSPENSION SYSTEMS BROCHURE 10 44 VIEW OF MITRED INTERSECTION FROM BENEATH 8 15 6 10 MAIN RUNNER 44 8 15 CROSS TEES LOCATED INTO MAIN RUNNER CROSS TEE TEE CUT TO UNEQUAL U PROFILE AT PERIMETER ARMSTRONG TRULOK SUSPENSION SYSTEMS SECTION TYPICAL CROSS SECTION TEE TRIMMED TO WALL ANGLE SILHOUETTE XL END CONNECTIONS AND PERIMETER DETAILS THESE DESIGNS ARE TYPICAL, NOT DEFINITIVE. ALL DIMENSIONS INDICATED ARE IN MILLIMETRES T26 SECTION 11/98