Problems? Call our Installation Helpline on ++44 (0) 845 862 6400 ACDC 1915 Instructions ACDC Lighting Systems Ltd, Innovation Works, Gisburn Road, Barrowford, Lancashire, BB9 8NB www.acdclighting.co.uk sales@acdclighting.co.uk *Ensure the unit is not powered during installation (ie disconnect unit from mains). *Connect the LED unit to the ACDC1915 (see specific instructions for each LED unit). *Connect the DMX lead(s), as per diagram below *Set the address on the DIP switches (on the side of the Driver) with the required DMX address section). For testing purposes, set all switches to up (colour cycle mode). *Connect mains lead (if not already attached). *Power on. *If the ACDC 1915 is set to self test mode (address 511) the red LED (CH1) should light first followed by a slow mix green (CH2) then blue (CH3). See table A for special address functions. *Please note, for any changes in the address DIP switch to take effect, the ACDC1915 must be powered off and on. SYSTEM SCHEMATIC MAINS IN MAINS IN MAINS IN ACDC 1915 ACDC 1915 ACDC 1915 DMX INPUT Lucina fitting EB+RGB are pre fitted with Molex (8way receptacle) connector which can be directly connected to 1915. Up to 1200mm of fittings may be connected to each DMX, Splitter blocks are available if multiple shorter fittings are to be connected: Last unit must be set to 'term' DMX Link Cat5 cable OUT PUT TO LED'S OUT PUT TO LED'S Electrical Data Lucina fittings OUT PUT TO LED'S A maximum of 32 ACDC1915's can be chained together on any DMX universe. For repeaters please contact dimmer supplier Splitter Block detail J3 Out put to fitting 3 J2 Out put to fitting 2 J1 Out put to fitting 1 J4 From DMX Any unused ports on splitter must have terminator connector in place Lucina ACDC1915 DMX Input Power (Max) Input Voltage Output Series Rating Dimming Control Min Dimmable Level 54W 95-240V AC 350mA 2 x 4-12 Rating Dimmable 0% Mechanical Data Dimensions Weight Temperature range Lifetime (MTBF) Max distance remote* Max Cable Length Standards IP Rating 45x282x57mm 790g -10° to 40°C 50,000 hrs 35M 70M CE, EN55015, SELV, F IP20 REV A - 20/11/09