Submittal
Submittal#: 3994-02
Submittal Date: 10/01/2012
1391 South Cherokee Street
Denver CO 80223
303 778-1373
To: Gerald H Phipps
5995 Greenwood Plaza Blvd
Suite 100
Greenwood Village CO 80111-4710
Project: 3994
DHHA Winter Park
145 Parsenn Road
Winter Park CO 80482
Prepared By: Doug Gardner
Item
Description
Action Required
Date Required
ARMSTRONG XL 15/16 Grid
ARMSTRONG Cirrus Tegular 589
Submit for Approval
Submit for Approval
10/05/2012
10/05/2012
Notes
Rebecca,
Please find attached samples, and spec data for the Armstrong Prelude 15/16 grid system and Armstrong Cirrus Tile for
approval.
Thank you,
Doug Gardner
Please sign and date this form as proof that you are in receipt of the above listed items.
Return form to Heggem-Lundquist Paint Co
Signed:
Date:
suspension systems
general application / exposed tee system
Recycled
Content:
25%
PRELUDE® XL 15/16″ Exposed Tee System
Prelude XL 15/16″ Exposed
Tee Systems combine
exceptional durability and
system stability with
installation ease.
Key Selection
Attributes
• PeakForm™
patented profile
increases
strength and stability for
improved performance during
installation
• SuperLock™ main beam clip
is engineered for a strong,
secure connection and fast
accurate alignment confirmed
with an audible click; easy to
remove and relocate (patent
pending)
• Double hem added for
improved lateral strength
(XL7342, XL7348, XL7328,
XL7318, XL7368, XL7378)
• Hot dipped galvanized coating
inhibits red rusting better than
electrogalvanized or painted
systems
• Rotary-stitched during
manufacture by a patented
method for additional torsional
strength and extra stability
during installation
• XL staked-on stab end detail
provides tight, secure locked
connection; easy to remove,
reuse and relocate
• State-of-the-art expansion
relief on Fire Guard options;
provides greater strength and
prohibits distortion of grid face
during installation
• 10-year limited warranty;
15-year with HumiGuard™
Plus and HumiGuard Max
products
Typical Applications
• Retail
• Schools
• Offices
• Hospitality
• Fire Guard applications based
on building construction and
local fire code requirements
Product Description
Materials
A. General:
ASTM C 635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposed
surfaces chemically cleansed, galvanized capping prefinished in baked polyester paint.
B. Components:
1. Main Beams: Double-web
construction, web height
1-11/16″ with peaked roof
top bulb and 15/16″ bottom
flange with prefinished steel
or aluminum capping; one
fire expansion relief per fire
rated main beam.
1/4" (6mm)
■
■
■
■
■
7300 (144″, routs 6″ OC, Intermediate-duty)
7301 (144″, routs 6″ OC, Heavy-duty)
7302 (120″, routs 6″ OC, Intermediate-duty)
7305 (140″, routs 10″ OC, Intermediate-duty)
734032 (3600mm, routs 150mm OC,
Intermediate-duty)
9/16"
(14mm)
1-11/16"
(43mm)
15/16"
(24mm)
Fire Guard Items
■ 8300 (144″, routs 6″ OC, Intermediate-duty)
■ 8301 (144″, routs 6″ OC, Heavy-duty)
■ 834033 (3600mm, routs 150mm OC,
Intermediate-duty)
■ Other
1/4"
1/4"
2A. Cross Tee: Double-web
construction, web height
1-11/16″, 15/16″ bottom
flange with prefinished steel
or aluminum capping and
override at each end.
Staked-on end detail allows
easy cross tee removal and
remounting.
■
■
■
■
■
■
■
XL7340 (48″, routs 12″ OC)
2A.
XL7341 (48″, routs 12″ OC)
1-11/16"
XL7330 (36″)
XL7380 (96″,
routs 12″ OC)
1-11/16"
XL7357 (60″, routs 6″ OC)
XL7358 (60″, routs 20″ OC)
15/16"
XL7390 (72″, routs 12″ OC)
1/4"
2B.
1/4" (6mm)
1-11/16"
(43mm)
1-1/2"
(38mm)
15/16"
(24mm)
15/16"
1/4"
(24mm)
1/4"
13/32"
(10mm)
1-1/2"
(38mm)
15/16"
15/16"
(24mm)
■ XL7342 (48″, routs 12″ OC)
2B. Cross Tee: Double-web
construction, web height
1-11/16"
1-1/2″, 15/16″ bottom
Fire Guard Items
1-11/16"
flange with prefinished steel
■ XL8320 (24″)
1-1/2" 1-1/2"
■ XL8340 (48″, routs 12 ″ OC)
or aluminum capping and
15/16"
override at each end.
12 ″ OC)
■ XL8341 (48″, routs15/16"
■ 833033 (1200mm, routs 300mm OC)
Staked-on end detail allows
easy cross tee removal and
■ Other
remounting.
1/4" (6mm)
1/4" (6mm)
1-11/16"
1-11/16"
1-1/2"
1-1/2"
15/16"
1/4"
■ XL7318 (12″)
2C. Cross Tee: Double-web
2C. 1/4"
construction, web height
■ XL7368 (20″)
1-1/2"
■ XL7328 (24″)
1-3/8″, 15/16″ bottom
1/4"
1/4"
(6mm) 1-3/8" (6mm)
flange with prefinished steel
■ XL7378 (30″)
1-1/2"
1-3/8"
■ XL7348 (48″)1-3/8"
or aluminum capping and
override at each end.
rout)
■ 312451 (300mm, center
15/16"
15/16" 1-3/8"
■ 312051 (600mm)
Staked-on end detail allows
(35mm)
easy cross tee removal and
■ 313051 (1200mm, center rout)
remounting.
Fire Guard Items
■ XL8323 (24″)
15/16"
(24mm)
■ 832052 (600mm)
1/4"
■ Other
2D. Cross Tee: Double-web
■ XL7148 (48″, routs 12 ″ OC)
1-3/8"
■ XL7128 (24″)
construction, web height 1-3/8"
1-3/16″, 15/16″ bottom
15/16"
flange with prefinished steel
cap and override at each
end. Staked-on end detail
allows easy cross tee
removal and remounting.
3. Wall Moldings: Hemmed
(angle molding) (shadow
molding) with prefinished
exposed flanges.
1/4"
1-3/8"
9/32" (7mm)
1-3/8"
(35mm)
15/16"
15/16"
(24mm)
2D.
■ 7800 (144″, angle molding, nominal
7/8″ bottom flange)
■ 7820 (120″, shadow molding,
nominal 15/16″ bottom flange, 1/2″ reveal)
1/4"
(6mm)
3/32"
1-3/16"
(2mm)
(30mm)
15/16"
(24mm)
7/8"
(22mm)
7/8"
(22mm)
15/16"
(24mm)
7800PER
10/22/97
1/2"
(13mm)
1/2"
(13mm)
15/16"
(24mm)
suspension systems
general application / exposed tee system
PRELUDE® XL
15/16″ Exposed Tee System
•
▲
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7302
Item 7301/8301
24″ x 48″
48″ x 48″
48″
49.27 lbs.
100.0 lbs.
72.32 lbs.
•
•
•
•
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7302
Item 7301/8301
•
12″ x 48″
48″ x 48″
48″
54.26 lbs.
12″ x 48″
48″ x 48″
48″
47.17 lbs.
100.0 lbs.
63.32 lbs.
•
•
•
•
HANGER SPACING
Lbs./LF. (Simple Span)**
4′
5′
13.0
6.35
8.73
16.5
13.0
6.35
6.35
13.0
8.73
16.5
13.0
6.35
13.0
6.35
•
•
ASTM
CLASS
Intermediate-duty
Heavy-duty
Intermediate-duty
Intermediate-duty
Heavy-duty
Intermediate-duty
Intermediate-duty
24″ x 48″
48″ x 48″
48″
69.27 lbs.
•
WEB
HEIGHT
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
•
Main Beam
Hanger Wire (•)
Main Beam Load Test Data
MAIN
BEAMS
LENGTH
144″
7300
144″
7301
144″
734032
8300/834033 144″
144″
8301
120″
7302
140″
7305
•
•
A. Main Beam to
Main Beam
•
LIGHT FIXTURE
•
Material
Hot dipped galvanized steel
Surface Finish
Baked polyester paint or anodized
Face Dimension
15/16″
Profile
Exposed tee
Cross Tee/Main Beam Interface
Override
End Detail
Main Beam: Staked-on clip
XL Cross Tee: Staked-on clip
Duty Classification
Intermediate or Heavy-duty
•
Maximum Fixture Weight
•
Physical Data
Cross Tee Load Test Data
1-1/2″
1-1/2″
1-3/8″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
16.59
9.00
7.35
7.47
7.57
11.90
12.23
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7305
Item 7301/8301
LIGHT FIXTURE
B. Cross Tee to
Cross Tee
330.0
CROSS TEES
MINIMUM LBS. TO PULL OUT
COMPRESSION/TENSION
20″ x 60″
60″ x 60″
48″
43.21 lbs.
56.47 lbs.
65.46 lbs.
•
•
•
•
•
•
•
▲
Main beams
Hanger Wire (•)
1. Fixture*
24″ x 48″
2. Planning Module
48″ x 48″
3. Hanger Spacing
48″
4. Item XL8340/XL7340 69.27 lbs.
4. Item XL7342
40.89 lbs.
5. Item XL8341/XL7341 81.67 lbs.
MINIMUM LBS. TO PULL OUT
COMPRESSION/TENSION
335.0
7301, 8301
24″ x 48″
60″ x 60″
48″
56.47 lbs.
Main Beams tested as follows: 7300 tested at 13.0 lbs./LF to 1/360 of 4′ span; 7301 tested at
16.5 lbs./LF to 1/360 of 4′ span.
Seismic Performance
MAIN BEAMS
7300, 7302, 7305,
734032, 8300
•
HANGER SPACING
Lbs./LF. (Simple Span)**
4′
40.45
40.45
33.0
40.45
58.28
59.78
20.84
23.11
6.0
12.25
•
•
WEB
HEIGHT
1-3/8″
1-3/8″
1-3/16″
1-3/8″
1-3/8″
1-1/2″
1-3/8″
1-11/16″
1-3/16″
1-11/16″
•
CROSS
TEES
LENGTH
XL7318/312451
12″
XL7368
20″
XL7128
24″
24″
XL7328/312051
24″
XL8323/832052
24″
XL8320
30″
XL7378
XL7330
36″
48″
XL7148
XL8340/833033/
48″
XL7340
XL7341/XL8341
48″
XL7342
48″
48″
XL7348/313051
60″
XL7357
XL7358
60″
XL7380
96″
XL7390
72″
•
All XL cross tees exceed 300 lbs. in both compression and tension.
• •
•
24″ x 24″
48″ x 48″
48″
80.55 lbs.
52.26 lbs.
100.0 lbs.
•
ICBO Reports
For areas under ICBO jurisdiction, see ICBO evaluation report number 5173 for allowable
values and/or conditions of use concerning the suspension system components listed on this
page. The report is subject to reexamination, revisions and possible cancellation.
**To derive maximum lbs/SF, divide the on-center spacing of the
component into the lbs/LF given in the load test data table.
Color Selection
Color Chip
■
■
■
■
■
■
■
WH - White
HA - Haze
PL - Platinum
BL - Tech Black
AR - Brass
WA - White Aluminum
HDC - Hot Dipped
Clear Coat
■
■
■
■
■
■
■
■
■
CR - Cream
YS - Oyster
AD - Adobe
AM - Mirror
NA - Natural Aluminum
MY - Gun Metal Grey
SG - Silver Gray
SA - Silver Satin
CM - Camel
•
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item XL8340/XL7340
5. Item XL8341/XL7341
• •
24″ x 48″
48″ x 48″
48″
49.27 lbs.
72.32 lbs.
•
12″ x 48″
48″ x 48″
48″
42.17 lbs.
63.32 lbs.
*Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is
based on single fixture only. For end-to-end fixtures or other configurations not shown,
consult your Armstrong representative.
NOTE: The above data is based on 48″ hanger wire spacing, board weight of 1 lb./SF,
maximum deflection of tees not to exceed 1/360 of the span, and suspension system
installed in accordance with ASTM C 636.
NOTE: Color chips included with samples of Armstrong grid. See your Armstrong representative for sample
material. NOTE: Items 7305, 7302, XL7340, XL7380, XL7357, XL7358, XL7128, XL7148, XL7348, XL7330,
XL7318, XL7368, XL7378, XL7390, XL8320, XL8341, XL7341 are available in white only.
TechLine™ / 1-877-ARMSTRONG
1-877-276-7876
armstrong.com
CS-3344-1205J
©2005 Armstrong World Industries, Inc.
Printed in the United States of America
CIRRUS ®
Tegular
10-YEAR
fine texture
Availability
Items 584, 589
Cirrus Beveled Tegular with Suprafine ® 9/16" Exposed Tee grid (Pg. 220)
Key Selection Attributes
• Refined visual
• Excellent sound absorption
• Ceiling-2-Ceiling™ Post-consumer Recycled
Content options: Items 589HRC, 539HRC,
584HRC, 535HRC. 65% Pre-consumer;
15% Post-consumer
• Smaller size panels available
(1 carton min. order).
Info: armstrong.com/specials
Typical Applications
• 30-Year Limited System Warranty against
visible sag (excludes items 535, 539, 581,
583), mold/mildew, and bacterial growth
• Offices
• Healthcare –
assists in addressing
HIPAA and FGI acoustical
requirements
• Conference rooms
• Department stores/retail
For special performance
applications, see Cirrus
Open Plan on pages 141-142.
Color Selection Due to printing limitations, shade may vary from actual product.
Items 584, 589 are available in colors. All other items are available in white only.
Colored ceilings are dye-lotted and should be segregated by dye lot. Do not mix.
White (WH)
Detail
Haze (HA)
Camel (CM)
Platinum (PL)
(Other Suspension Systems compatible. Refer to listing on page 140.)
Cirrus
Beveled Tegular
139
Cream (CR)
Cirrus
Angled Tegular
Cirrus
Beveled Tegular with
Suprafine 9/16"
Exposed Tee grid
TechLineSM 877 ARmSTRONG
Cirrus
Angled Tegular with
Prelude® 15/16"
Exposed Tee grid
armstrong.com/ceilings (search: cirrus)
Angled Tegular
hamford Tegular
files Chamfered
Beveled Tegular
oncealed
e Edge K4C4
" Flush Tegular
Ledges
®
Up to 80%
LEED® Credits
Tegular
Energy Waste Recycled
fine texture
Visual Selection
✔
✔ ✔
✔
Location Dependent
65% Pre-consumer;
15% Post-consumer
15/16" Angled Tegular
Ultima Plank ShipLap
Long Edge Detail
Ultima Plank ShipLap
K2C2 Short
Ultima Plank ShipLap
Long Edge Detail
Ultima Plank ShipLap
Beveled Tegular Short
✔
Acoustics Low Emitting
7/8" Items
3/4" Items
Performance Selection
9/16" Angled Tegular
LEED for Schools
Local Renewable Daylight
Content Materials Materials & Views
Mgmt
✔
The post-consumer
recycled content of
these items is from
reclaimed ceilings
Square Lay-in
armstrong.com/greengenie
or CHPS
✔
✔
$$$$$
$$$$$
Dots represent highest level of performance.
Grid
UL Classified
Drawings
Acoustics
FireLight
Sag Anti-Durable
Recycle
Cat. pgs.
Edge
Item Dimensions
NRCCAC Rating
Reflect Resist
Microbial
Program
226-228
Profile
No.
or armstrong.
com/catdwg
15/16" Chamford Tegular
Cirrus Tegular
9/16" Chamfered Tegular
Cirrus Profiles Chamfered
Classic Step Tegular
Cirrus Profiles Chamfered
9/16"
31-34, 54
Beveled Tegular
589
589M
589HRC
538
2' x 2' x 7/8"
9/16" Square Cut
Tegular
Square Tegular
538M
600
x 600 15/16"
x 22mm
31-34, 54
9/16"
Beveled Tegular
15/16" Beveled Tegular
2' x 2' x 3/4"
600 x 600 x 19mm
2' x 2' x 3/4"
15/16 Classic Step Tegular
~8-ID (99) (drw 10)
0.70 35
Class A
• 0.86
HumiGuard+ BioBlock+
Standard
Yes
• • • •
0.70 38 Class A
Tegular
• 9/16" Wrapped
• 0.86
Standard
• • • •
Graphis Wrapped Linear
and Cubic Fire
0.35 35
31
577
577M
2' x 2' x 3/4"
Guard
600 x 600 x 19mm
0.86
Standard
• • • •
31-34, 54
576
576M
2' x 2' x 7/8"
A x 22mm
B
600 x 600
0.70 40
Class A
C •
• D
0.86
Standard
• • • •
0.70
40
Class A
C
D
15/16" Vector C &
D
0.86
Standard
Standard
• • •
583 Linear Cubic
2' x 4' x 7/8"
A
B
Beveled Crossgate
15/16"
Vector
583M
600 x 1200
x 22mm
Concealed 54
9/16" Wrapped
Linear and
31-34,
Square Edge K4C4
Mixed
Corner “B”
(Flumes, Graphis Linear Corner
& Dots & Squares)
539
539M
539HRC
31-34, 54
Long Edge Detail
7
15/16" Flush Tegular
Ledges
Ultima Plank
7ShipLap
Long Edge Detail
578
NeoCubic
Soft Look Radiused Tegular
2' x 2' x 3/4"
0.35 35
Fire Guard
600 x 600 x 19mm
0.86
Standard
• • • •
534
534M
2' x 2' x 7/8"
600 x 600 x 22mm
0.70 38
Class A
• • 0.86
Standard
• • • •
572
572M
2' x 2' x 7/8"
600 x 600 x 22mm
0.70 40
Class A
• • 0.86
Standard
• • • •
Ultima
Plank ShipLap
581
Beveled Tegular Short
7
9/16" Square Cut Tegular
2' x 4' x 3/4"
0.70 35
Class A
0.86
Standard
Standard
600 x 1200 x 19mm
• • • •
2' x 4' x 3/4"
578M
Ultima
Plank ShipLap
K2C2 Short
7
9/16" Flush Tegular
Ledges
Classic
Step Tegular
•
584
2' x 2' x 3/4"
0.70 35
Class A
0.86
Standard
584M
600 x 600 x 19mm
• • • • •
584HRC
2' x 2' x 3/4"
9/16" Cubic Graphis
Concealed
15/16"
7
Angled Tegular
Concealed Beveled K4C4
Tongue and Groove
7
15/16"
Angled Tegular Ultima Plank ShipLap
•
581M
2' x 4' x 7/8"
600 x 1200 x 22mm
535
535M
535HRC
2' x 4' x 3/4"
600 x 1200 x 19mm
2' x 4' x 3/4" 15/16" Square Tegular
15/16
Classic Step
0.70
40Tegular
~8-ID (99) (drw 10)
Class A
0.86
Standard
Standard
• • •
0.70 35
Class A
• 0.86
Standard
Standard
• • •
•
• 9/16" Wrapped Tegular
Graphis Wrapped Linear
and Cubic
Suspension Systems
15/16"9/16"
A
Linear Cubic
Beveled Crossgate
B
Prelude ®
Prelude XL ®
A
B
Fire Guard
15/16" Vector
C
D
Interlude ®
C
D
15/16" Vector C & D
Silhouette ®
Bolt-Slot
Sonata ®
Suprafine ®
Suprafine XL ®
Fire Guard
Trimlok ®
Screw-Slot
Physical Data
Sag Resistance
HumiGuard ® Plus – superior resistance to sagging
in high humidity conditions up to, but not including,
standing water and outdoor applications.
Material
Wet-formed mineral fiber
9/16"Surface
Cubic GraphisFinish
Concealed
NeoCubic
Soft Lookpaint
Radiused Tegular
Factory-applied
latex
Fire Performance
ASTM E84 and CAN/ULC S102 surface burning
characteristics. Flame Spread Index 25 or less.
Smoke Developed Index 50 or less. (UL labeled)
Fire Guard ™: A fire resistive ceiling when used in
applicable UL assemblies
ASTM E1264 Classification
Type III, Form 1, Pattern E I
Fire Class A
SM
TechLine / 1 877 ARmSTRONG
armstrong.com/ceilings (search: cirrus)
CS-3012-611
VOC/Formaldehyde Emissions
Meets CA Dept. of Health Services Standard Practice for
the testing of VOC Emissions and is listed on CHPS High
Performance Products Database for Low-Emitting Materials.
Anti Mold/Mildew & Bacteria
BioBlock ® Plus contains an anti-microbial treatment and
provides guaranteed resistance against growth of mold/
mildew and Gram-positive and Gram-negative odor/
stain-causing bacteria for 30 years.
30-Year Performance Guarantee & Warranty Information
Details in back of catalog or at armstrong.com/warranty
Application Considerations
Not recommended for rooms containing MRI equipment.
Weight; Square Feet/Carton
534, 538, 572, 576 – 1.38 lbs/SF; 40 SF/ctn
535, 539, 581, 583 – 1.21 lbs/SF; 48 SF/ctn
577, 578 – 1.25 lbs/SF; 48 SF/ctn
584, 589 – 1.06 lbs/SF; 48 SF/ctn
Insulation Value
R Factor – 1.9 (BTU units) R Factor – 0.33 (Watts units)
LEED® is a registered trademark of the U.S. Green Building Council
All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2011 AWI Licensing Company • Printed in the United States of America
140
M i n eral F iber
Groove
CIRRUS
Recycled
Content:
Download