Louis Kloss

advertisement
Thomco Job # 3064
RECORD OF CONTRACTOR SUBMITTAL
TO:
So Cal Gas Co.
1801 S. Atlantic Blvd.,
Monterey Park, CA 91754
ATTN / C/O:
Submittal #: 095100-01
Date: 10/23/14
Tom Souders, So Cal Gas Co.
PROJECT: Monterey Park Learning Center
PRIORITY:
URGENT
NORMAL
FOR:
INFORMATION ONLY
AS REQUESTED
REFERENCE
YOUR FILES
SUBMITTALS FOR APPROVAL
RESPONSE REQUIRED
SENT BY:
No.
COPIES
SPECIFICATION
DATED
1
5
095100
10/23/14
2
5
095100
10/23/14
3
5
095100
10/23/14
4
5
095100
10/23/14
5
5
095100
10/23/14
6
5
095100
10/23/14
1
095100
10/23/14
HAND DELIVER
U.S. MAIL
ELECTRONIC
FAX
OTHER
DESCRIPTION
Acoustic Ceiling Product Data & Samples
Submittal
Armstrong Ultima “Vector” Ceiling Tile
Sample
Armstrong Ultima “Beveled Tegular” Ceiling
Tile Sample
Armstrong Silhouette XL 9/16” Ceiling Grid
Sample
Armstrong Prelude XL HRC Ceiling Grid
Sample
Armstrong Woodworks Grille “MAPLE”
Wood Ceiling Sample
7
8
Acoustic Ceiling Electronic Product Data
Submittal
REMARKS:
_____________________________________________________________________________________
PLEASE REVIEW, STAMP AND RETURN AT LEAST (3) COPIES TO THE GENERAL CONTRACTOR.
_____________________________________________________________________________________
This submittal has been reviewed for conformance to drawings and
specifications.
SIGNED:
Louis Kloss
Louis Kloss, Project Manager
COPIES TO:
A/E of Record or Designer
Thomco Project Superintendent
Thomco File: Submittal File
Owner / Construction Manager:
Subcontractor:
Ceiling Concepts Inc.
Ceiling Systems
Lighting
Air Distribution
10527 Humbolt Street Los Alamitos, CA 90720 (562) 493-8521 Lic.#461151 FAX (562) 493-8742
Transmittal
To:
Thomco
Date:
10/20/2014
Project: SCG MP Learning Center
Attn:
Louis Kloss
Monterey Park, CA
We wish to submit the following materials and technical data that Ceiling
Concepts Inc. will be using on the above listed project for your
consideration and approval. Thank you.
5 ea.
samples of Armstrong Silhouette suspension w/ technical data sheets
5 ea.
samples of Armstrong Ultima #1912 w/ technical data sheets
5 ea.
samples of Armstrong Prelude 15/16" Suspension w/ technical data sheets
5 ea.
samples of Armstrong Ultima Vector #1920 w/ technical data sheets
5 ea.
samples of Armstrong Woodworks Grille w/ technical data sheets
Thanks again,
Jarrod Yuchno
armstrong.com/greengenie
LEED ®
9/16" Slotted Tee System
local*
materials
silhouette ® xL ® 1/4" reveal
Recycled
Content
recycled
content
Availability
waste
mgmt
Up to
30%
10-YEAR
*Location Dependent
Key Selection Attributes
Seismic Rx® Suspension System saves
time and money; Armstrong offers an
ICC-ES approach to installations
(ESR-1308)
• Hot dipped galvanized coating inhibits
red rusting better than electro­galvanized
or painted systems
• Some items available in metric sizes
• Rotary-stitched during manufacture for
additional torsional strength and extra
stability during installation; maintains
size and shape of reveal when cutting
perimeter cross tees
2
• XL staked-on end detail provides secure
locked connection
•
Typical Applications
Available with black reveal
• 10-Year Limited System Warranty; 30-Year
Limited Ceiling Systems Warranty when
used with HumiGuard® Plus products
• Main beams and cross tees can be ordered
with special sizing and route spacing for
your project needs
™
• FastSize main beams and cross tees can
be ordered with special sizing and route
spacing for your project needs in one carton
minimums with two week lead times
•
•
Blizzard White powder-coated finish
coordinates with Optima®, Ultima®,
Calla™, and Lyra™ ceiling panels
for a clean, seamless, monolithic
installed visual.
NOTE: Additional Silhouette 1/4" reveal items for
TechZone™ Integrated Ceiling Systems are listed
in the TechZone Technical Guide (BPCS-4486).
Available online at armstrong.com/techzone
Visual Selection
Performance Packaging
Route
Spacing
Face
Profile Description
Item
No.
Offices
Education
• Retail
• Hospitality
•
Dimensions
Notching (Inches)
Silhouette XL – 1/4" Reveal
Hanger
Spacing*
Lbs./Lin. Ft.
Fire
Guard ™
4 Ft.
5 Ft.
Seismic
Category
Pcs./ Lin.Ft./
Ctn. Ctn.
Dots represent high
level of performance.
7601_ _❖
9/16"
12' HD Main Beam – Notched 24" O.C.
24” O.C.
144 x 9/16 x 1-3/4" 16.35
7.80
–
•
20
240
7612_
9/16"
12' HD Main Beam – Unnotched
–
144 x 9/16 x 1-3/4" 16.35
7.80
–
•
20
240
_❖
◆
9/16"
12' ID Main Beam – Notched 24" O.C.
24” O.C.
144 x 9/16 x 1-3/4" 13.10
6.61
–
–
20
240
7602_ _❖
9/16"
10' ID Main Beam – Notched 24" O.C.
24” O.C.
120 x 9/16 x 1-3/4" 13.10
6.61
–
–
20
200
7603_
_❖
9/16"
12' ID Main Beam – Notched 48" O.C.
48” O.C.
144 x 9/16 x 1-3/4" 13.10
6.61
–
–
20
240
7606_ _❖
9/16"
10' ID Main Beam – Notched 30" O.C.
30” O.C
120 x 9/16 x 1-3/4" 13.10
6.61
–
–
20
200
XL7680_
_❖
9/16"
8' Cross Tee – Unnotched
–
96 x 9/16 x 1-3/4"
12.59**
–
–
•
20
160
XL7690_
_❖
7600 _ _
9/16"
6' Cross Tee – Unnotched
–
72 x 9/16 x 1-3/4"
12.59**
–
–
•
20
120
XL7650_ _❖ 9/16"
5' Cross Tee – Unnotched
–
60 x 9/16 x 1-3/4"
–
6.09
–
•
30
150
XL7655_
5' Cross Tee – Center-notched, both sides
–
60 x 9/16 x 1-3/4"
–
5.71
–
•
30
150
XL7654_ _❖ 9/16"
5' Cross Tee – Notched, both sides at 20", 40" –
60 x 9/16 x 1-3/4"
–
5.71
–
•
30
150
XL7651_
5' Cross Tee – Notched, one side at 20", 40"
–
60 x 9/16 x 1-3/4"
–
5.71
–
•
30
150
_❖
_❖
9/16"
9/16"
4' Cross Tee – Unnotched
–
48 x 9/16 x 1-3/4"
13.53
–
–
•
60
240
XL7645 _ _◆ 9/16"
4' Cross Tee – Center-notched, both sides
–
48 x 9/16 x 1-3/4"
12.85
–
–
•
60
240
XL7646_
XL7640_ _
◆
9/16"
4' Cross Tee – Center-notched, one side
–
48 x 9/16 x 1-3/4"
13.21
–
–
•
60
240
XL7670_ _❖ 9/16"
30" Cross Tee – Unnotched
–
30 x 9/16 x 1-3/4"
39.86 @ 2.5' –
–
•
60
150
XL7620 _ _
2' Cross Tee – Unnotched
–
24 x 9/16 x 1-3/4"
69.69
71.66 @ 2' –
•
60
120
9/16"
1' Cross Tee – Unnotched
–
12 x 9/16 x 1-3/4"
69.69
71.66
•
120
120
9/16"
Main beams L: 36" - 144" / Cross tees L: 6" - 144" / Route spacing 3" from ends, 6" thereafter
XL7610_
_❖
◆
_❖
FastSize
9/16"
9/16"
–
Varies Varies
ASTM Class HD - Heavy-duty
ID - Intermediate-duty
LD - Light-duty
Item
No.
Length
Description
(A)
Flange
(B)
Flange
(C)
Flange
Pcs./
Ctn.
Lin. Ft./
Ctn.
Suggested Wall Moldings and Shadow Moldings (Additional molding options available. See catalog pgs. 269-270)
7804_ _❖
12' Hemmed Angle Molding
144"
9/16"
7/8"
–
30
360
7873_ _❖
10' Shadow Molding
120"
9/16"
15/16"
3/8”
30
300
7878_ _❖***
10' Seismic Shadow Molding
120"
15/16"
15/16"
3/8”
30
300
* Simple Span
** Wire at 4'
*** Suitable for Category D, E, F Seismic Installation with BERC2 clip
◆ Items available in Standard and Blizzard White powder-coated finish
❖ Items available in Blizzard White powder-coated finish only
When specifying or ordering items with a color or finish, add the two-letter suffix to the end of the item number (e.g., 7301B L – Tech Black)
TechLineSM 877 ARmSTRONG armstrong.com/suspensionsystems
silhouette ® xL ® 1/4" reveal
9/16” Slotted Tee System
Maximum fixture weight
Configuration
A
Fixture
Item
No.
B
A
Planning Module
A
B
B
Hanger Spacing
A
B
Maximum Weight
A
B
•)
Main Beam to Main Beam – Drawing Key: Main beam ( ▲| ) Cross tee ( --- ) Hanger wire ( +
•
•
•
•
•
•
•
•
7600/7602
7601
•
•
•
•
•
•
•
•
24" x 48"
24" x 48"
48" x 48"
48" x 48"
48"
48"
73.0 lbs.
76.0 lbs.
73.0 lbs.
76.0 lbs.
24" x 48"
24" x 48"
48" x 48"
48" x 48"
48"
48"
75.0 lbs.
75.0 lbs.
75.0 lbs.
75.0 lbs.
48"
48”
48"
48”
59.0 lbs.
59.0 lbs.
41.0 lbs.
41.0 lbs.
Main beams tested as follows: 7600 tested at 13.1 lbs/LF to 1/360 of 4' span; 7601 tested at 16.35 lbs/LF to 1/360 of 4' span.
•)
Cross Tee to Cross Tee – Drawing Key: Main beam ( ▲| ) Cross tee ( --- ) Hanger wire ( +
•
•
•
•
•
•
•
•
XL7645
XL7646
24" x 48"
24” x 48”
24" x 48"
24” x 48”
48" x 48"
48” x 48”
48" x 48"
48” x 48”
Cross tees tested as follows: XL7645 tested at 12.0 lbs/LF to 1/360 of 4' span.
Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixture only. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative.
NOTE: The above data is based on 48" hanger wire spacing, board weight of 1 lb./SF, m
­ aximum deflection of cross tees not to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636.
Color And Finish Selection
Accessories
Standard
BERC2 – 2" Beam End Retaining Clip – Allows you to
13/32"
create a code compliant Seismic D, E, F ceiling
installation
(10mm)
while eliminating the need to use 2" wall molding or
1-3/4"
spreader bars.
(44mm)
ALBERC2 (aluminum)
White
(WH)
◆
1/4" (6mm)
Powder-coated
Finish❖
◆
Tech Black
(BL)
1/4" (6mm)
MCC4 – Silhouette 1/4" Reveal
13/32"
Miter Closure Clip – Eliminates
(10mm)
main beam and cross tee miters.
1-3/4"
(44mm)
5/16" (8mm)
Blizzard
White
(ZW)
5/16" (8mm)
1/4" (6mm)
200 pcs/bucket
Available with Black reveal, add suffix BI, (e.g., 7600B L)
GCWA – Grip Clip Wall
Attachment – Joins main beam or
cross tee to wall
molding via locking
barbs without pop
rivets or screws.
1/8" (3mm)
9/16"
(14mm)
9/16"
(14mm)
250 pcs/bucket
200 pcs/bucket
❖ Items available in powder-coated finish
Details
For more information, see submittal BPCS-3157.
SILHOUETTE XL
Main Beam
1/4" (6mm)
1/4" (6mm)
SILHOUETTE XL
Main Beam with
1/4" Reveal
7/8" Hemmed
Angle Molding
13/32"
(10mm)
SILHOUETTE XL
Cross Tee
Shadow Molding
13/32"
(10mm)
B
1-3/4"
(44mm)
1-3/4"
(44mm)
C
SILHOUETTE XL
Cross Tee
5/16" (8mm)
5/16" (8mm)
A
1/4" (6mm)
1/4" (6mm)
9/16"
(14mm)
9/16"
(14mm)
Seismic Performance
Main Beams
7600/804042, 7606, 7602, 7601, 7603
Minimum Lbs. To Pull Out Compression/Tension
340.0, 392.9, 340.0
Cross Tees
XL7610, XL7620/802042, XL7640, XL7645/803042,
XL7646, XL7650, XL7670, XL7655, XL7680, XL7690
Minimum Lbs. To Pull Out Compression/Tension
299.5
ICC Reports
For areas under ICC jurisdiction, see ICC evaluation report
number ESR-1308 for allowable values and/or conditions
of use concerning the suspension system components
listed on this page. The report is subject to reexamination,
revisions and possible cancellation.
To derive maximum lbs/sf, divide the on-center spacing of
the component into the lbs/lf given in the load test data table.
shadow molding
Physical Data
Material
Double-web hot dipped galvanized steel
Face Dimension
9/16"
End Detail
Main Beam: Coupling
Surface Finish
Baked polyester paint or powder-coated finish
Profile
Bolt-slot
Cross Tee: Staked-on clip
Cross Tee/Main Beam Interface
Mitered
TechLineSM / 1 877 ARmSTRONG
1 877 276 7876
armstrong.com/suspensionsystem
BPCS-3157-314
LEED® is a registered trademark of the U.S. Green Building Council
All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2014 AWI Licensing Company • Printed in the United States of America
ULTIMA ®
Tegular
10-YEAR
Availability
fine texture
Ultima Beveled Tegular with Suprafine ® 9/16" Exposed Tee grid
Ultima Beveled Tegular with Sonata ® 9/16" Dimensional Tee grid
Key Selection Attributes
• Smooth, clean, durable finish –
Washable, Impact-resistant,
Scratch-resistant, Soil-resistant
• Scrubbable and water-repellent (Ultima High
Washability)
• Excellent sound absorption
• High recycled content options – items 1911HRC,
1912HRC, 1914HRC and 1915HRC – 65%
pre-consumer, 15% post-consumer
• 30-Year Limited System Warranty against
visible sag (excludes item 1905), mold/mildew
and bacterial growth
• Visual coordinates with OPTIMA® for mixed
(open/closed plan) applications
Ty p i c a l A p p l i c a t i o n s
• Non-directional visual reduces installation
time and scrap
• Compatible with the TECHZONE™ Ceiling
Systems. Items 1905, 1911, 1912, 1914,
1915 only.
• Smaller size panels available (1 carton min.
order). Info: armstrong.com/specials
• Excellent sound blocking – items 1951, 1952
• Plank sizes available (search: Ultima Plank)
• Meets USDA/FSIS guidelines for use in food
processing areas (items 1936 and 1937)
Detail
• Offices
• Healthcare – assists in addressing
HIPAA requirements
• Classrooms
• Corridors
• Lobbies/reception areas
• Department stores/retail
• Kitchens, dining rooms and
food preparation areas
(Items 1936 and 1937)
Color
White (WH)
ULTIMA
Beveled Tegular
ULTIMA High Washability
Tegular
Items 1911, 1912, 1914, 1915
ULTIMA with
SUPRAFINE 9/16"
Exposed Tee grid
ULTIMA with
SILHOUETTE® XL® 9/16"
Bolt-Slot 1/4" Reveal grid
51-80%
Recycled
Content:
ULTIMA ®
armstrong.com/greengenie
LEED Credits
®
Energy
Tegular
Waste
Mgmt
✔
fine texture
LEED for Schools
Recycled
Content
✔
✔
Local
Materials
✔
Renewable
Materials
Location Dependent
✔
Daylight
& Views
Acoustics
✔
Low Emitting
or CHPS
✔
✔
$$$$$
Visual Selection
Performance Selection
Dots represent highest level of performance.
UL Classified
Acoustics
NRC CAC
Fire
Rating
Light
Reflect
1' x 2' x 3/4"
300 x 600 x 19mm
N/A N/A
Class A
0.90
1912
1912M
1912HRC*
2' x 2' x 3/4"
600 x 600 x 19mm
2' x 2' x 3/4"
0.70 35 ◆
1952
1952M
2' x 2' x 3/4"
600 x 600 x 19mm
0.60
1915
1915M
1915HRC*
2' x 4' x 3/4"
600 x 1200 x 19mm
2' x 4' x 3/4"
0.70
1905
1905M
30" x 30" x 3/4"
750 x 750 x 19mm
0.70
15/16"
1917
Beveled Tegular 1917M
1' x 2' x 3/4"
300 x 600 x 19mm
N/A N/A
1911
1911M
1911HRC*
2' x 2' x 3/4"
600 x 600 x 19mm
2' x 2' x 3/4"
0.70
1951
1951M
2' x 2' x 3/4"
600 x 600 x 19mm
0.60
1914
1914M
1914HRC*
2' x 4' x 3/4"
600 x 1200 x 19mm
2' x 4' x 3/4"
0.70
Edge
Profile
Item
No.
Dimensions
Sag
Resist
AntiMicrobial
VOC
Formaldehyde
Durable
Recycle
Program
ULTIMA † Tegular
9/16"
1916
Beveled Tegular 1916M
●
Class A
●
●
●
●
●
●
●
●
●
0.90
S
0.90
●
40
Class A
●
35
Class A
35
Class A
●
0.90
35
Class A
●
40
Class A
●
35
Class A
●
●
●
●
●
●
●
●
●
●
●
–
●
●
●
●
●
–
●
●
●
●
●
–
●
●
●
●
●
–
●
●
●
●
●
–
●
●
●
●
●
–
●
●
●
●
●
●
●
–
●
●
●
●
●
●
●
–
●
●
●
●
●
No Added
No Added
0.90
●
●
No Added
●
0.90
●
Yes
●
No Added
●
0.90
●
Scrub
●
No Added
0.90
●
Wash Impact Scratch Soil
No Added
●
Class A
No Added
No Added
0.90
●
●
HumiGuard+ BioBlock+
●
No Added
ULTIMA High Washability (see Health Zone ™ Ultima, CS-4066)
9/16"
1936
Beveled Tegular
2' x 2' x 3/4"
15/16"
1937
Beveled Tegular
2' x 2' x 3/4"
0.70 35
Class A 0.86
●
0.70 35
●
No Added
Class A 0.86
●
●
●
●
●
●
●
●
●
●
●
●
●
●
No Added
S = Standard
◆
† US Patent 5,674,594
* The recycled content of this product is: 65% pre-consumer; 15% post-consumer
1912-CAC 33 on 9/16" Interlude, Sonata, Suprafine
Suspension Systems
9/16"
Standard: Interlude ®, Silhouette ® Bolt-Slot, Sonata ®, Suprafine ®, Trimlok ® Screw-Slot
15/16"
Standard: Prelude ®
Physical Data
Material
Wet-formed mineral fiber with DuraBrite ® acoustically
transparent membrane
1936, 1937 – Wet-formed mineral fiber with DuraBrite ®
acoustically transparent water-repellent membrane
Surface Finish
DuraBrite with factory-applied acrylic latex paint
Fire Performance
ASTM E84 and CAN/ULC S102 surface burning
characteristics. Flame Spread Index 25 or less.
Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 Classification
Type IV, Form 2, Pattern E
Fire Class A
TechLineSM / 1 877 ARMSTRONG
1 877 276 7876
armstrong.com/ceilings
(search: ultima)
CS-3039-909
Sag Resistance
HumiGuard ® Plus – superior resistance to sagging in high
humidity conditions up to, but not including, standing
water and outdoor applications.
No-Added Formaldehyde
No-added formaldehyde – free of formaldehyde-based
resins. Outperforms CHPS Section 01350 requirements.
(Independent test reports available upon request.)
Anti-Mold/Mildew & Bacteria
BioBlock ® Plus contains an anti-microbial treatment and
provides guaranteed resistance against growth of
mold/mildew and Gram-positive and Gram-negative
odor/stain-causing bacteria for 30 years.
Insulation Value
R Factor – 2.2 (BTU units)
R Factor – 0.39 (Watts units)
Backloading Recommendation
Contact TechLine for specific information
30-Year Performance Guarantee & Warranty Information
See warranty details at armstrong.com/warranty
Application Considerations
1′ x 2′ products are not intended for a full ceiling installation
and are not UL Classified for acoustics.
Cleaning Recommendations (Items 1936, 1937 only)
To clean panel, use a clean, white cloth with water or a mild
detergent and wipe surface. To disinfect panel, lightly spray
surface and wipe clean with a clean, white cloth. Acceptable
colorless disinfectants include:
• Sodium hypochlorite • Hydrogen peroxide
• Isopropyl alcohol
• Quaternary ammonium
Weight; Square Feet/Carton
1905 – 1.05 lbs/SF; 62.5 SF/ctn
1911, 1912, 1914, 1915 – 1.05 lbs/SF; 48 SF/ctn
1916, 1917 – 1.05 lbs/SF; 24 SF/ctn
1951, 1952 – 1.31 lbs/SF; 48 SF/ctn
1936, 1937 – 1.08 lbs/SF; 48 SF/ctn
LEED® is a registered trademark of the U.S. Green Building Council
All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2009 AWI Licensing Company • Printed in the United States of America
Recycled
Content:
PRELUDE ® XL
30%
15/16" Exposed Tee System
Key Selection
Attributes
Product Description
Materials
• Seismic Rx Suspension
System saves time and money;
ICC-ES approach to installations
(ESR-1308)
A. General: ASTM C635 (Intermediate-duty) (Heavy-duty) main beam classification, commercial-quality hot dipped galvanized steel. Exposed
• PeakForm® patented profile
increases strength and
stability for improved
performance during
installation
1. Main Beams: Double-web
construction, web height 1-11/16″
with peaked roof top bulb and
15/16″ bottom flange with
prefinished steel or aluminum
capping*; one fire expansion relief
per fire rated main beam.
®
• SuperLock™2 main beam clip
is engineered for a strong,
secure connection and fast
accurate alignment confirmed
with an audible click; easy to
remove and relocate
• Hot dipped galvanized coating
inhibits red rusting better than
electrogalvanized or painted
systems
surfaces chemically cleansed, galvanized steel or aluminum capping prefinished in baked polyester paint or annodized.
B. Components:
* NOTE: Fire Guard items available in
steel capping only.
2A. Cross Tee: Double-web construction,
web height 1-11/16″, 15/16″ bottom
flange with prefinished steel or
aluminum capping and override at
each end. Staked-on end detail
allows easy cross tee removal and
remounting.
• Rotary-stitched during
manufacture by a patented
method for additional torsional
strength and extra stability
during installation
• XL2 staked-on stab end detail
provides tight, secure locked
connection; easy to remove,
reuse and relocate
• State-of-the-art expansion relief
on Fire Guard™ options;
provides greater strength and
prohibits distortion of grid face
during installation
• 10-year limited warranty;
30-year with HumiGuard® Plus
■ XL7342 (48″, routs 12″ OC)
2C. Cross Tee: Double-web construction,
web height 1-3/8″, 15/16″ bottom
flange with prefinished steel or
aluminum capping and override at
each end. Staked-on end detail
allows easy cross tee removal and
remounting.
■ XL7318 (12″)
■ XL7368 (20″)
■ XL7328 (24″)
■ XL7378 (30″)
■ XL7348 (48″)
■ 312451 (300mm, center rout)
■ 312051 (600mm)
■ 313051 (1200mm, center rout)
Fire Guard Items
■ XL8323 (24″)
■ 832052 (600mm)
■ Other
• Retail
• Offices
• Hospitality
• Fire Guard applications based
on building construction and
local fire code requirements
2D. Cross Tee: Double-web construction,
web height 1-3/16″, 15/16″ bottom
flange with prefinished steel cap and
override at each end. Staked-on end
detail allows easy cross tee removal
and remounting.
Wall Moldings:
3A. Angle molding: hemmed with
prefinished exposed flanges
Color Selection
■
■
■
■
■
■
■
■
■
■
■
■
WH - White
HA - Haze
VA - Vanilla †
CM - Camel
YS - Oyster †
PL - Platinum
AD - Adobe †
AR - Brass
AM - Mirror
BL - Tech Black
SG - Silver Grey
MY - Gun Metal Grey
■ ST - Slate
■ WK - Wolf †
■ WA - White
Aluminum
■ NA - Natural
Aluminum
■ SA - Silver Satin
■ HDC - Hot Dipped
Clear Coat
■ PW - Pewter †
■ BZ - Bronze†
■ SL - Silver †
† Only available on 7301, XL7342, XL7328, and 7800
NOTE: Color chips included with samples of Armstrong grid.
See your Armstrong representative for sample material.
NOTE: Items 7305, 7302, XL7340, XL7380, XL7357,
XL7358, XL7128, XL7148, XL7348, XL7330, XL7318,
XL7368, XL7378, XL7390, XL8320, XL8341, XL7341
are available in white only.
NOTE: 8300, XL8340 and XL8323 are available in white
and black only.
3B. Shadow molding: hemmed with
prefinished exposed flanges
3C. Shadow Molding: (Compatible
with Seismic Rx® and BERC 2)
3D. Channel molding: hemmed with
prefinished exposed flanges
1/4" (6mm)
9/16"
(14mm)
1-11/16"
(43mm)
15/16"
(24mm)
■ XL7340 (48″, routs 12″ OC)
■ XL7341 (48″, routs 12″ OC)
■ XL7330 (36″)
■ XL7380 (96″, routs 12″ OC)
■ XL7357 (60″, routs 6″ OC)
■ XL7358 (60″, routs 20″ OC)
■ XL7390 (72″, routs 12″ OC)
Fire Guard Items
■ XL8320 (24″)
■ XL8340 (48″, routs 12 ″ OC)
■ XL8341 (48″, routs 12 ″ OC)
■ 833033 (1200mm, routs 300mm OC)
■ Other
2B. Cross Tee: Double-web construction,
web height 1-1/2″, 15/16″ bottom
flange with prefinished steel or
aluminum capping and override at
each end. Staked-on end detail
allows easy cross tee removal and
remounting.
Ty p i c a l A p p l i c a t i o n s
• Education
■ 7300 (144″, routs 6″ OC, Intermediate-duty)
■ 7301 (144″, routs 6″ OC, Heavy-duty)
■ 7302 (120″, routs 6″ OC, Intermediate-duty)
■ 7305 (140″, routs 10″ OC, Intermediate-duty)
■ 734032 (3600mm, routs 150mm OC, Intermediate-duty)
Fire Guard Items
■ 8300 (144″, routs 6″ OC, Intermediate-duty)
■ 8301 (144″, routs 6″ OC, Heavy-duty)
■ 834033 (3600mm, routs 150mm OC,
Intermediate-duty)
■ Other
1/4" (6mm)
1/4" (6mm)
1-11/16"
(43mm)
1-1/2"
(38mm)
15/16"
(24mm)
15/16"
(24mm)
1/4"
(6mm)
2C.
1-3/8"
(35mm)
15/16"
(24mm)
2D.
■ XL7148 (48″, routs 12 ″ OC)
■ XL7128 (24″)
1/4"
(6mm)
3/32"
1-3/16"
(2mm)
(30mm)
15/16"
(24mm)
Item #
■ 7800
■ 7807
■ 7808
■ HD7801
Length
144″
120″
120″
120″
(A)
Flange
7/8″
2″
2″
7/8″
(B)
Height
7/8″
1″
2″
7/8″
Item #
■ 7875
Length
120″
(A)
Flange
3/4″
(B)
Height
15/16″
(C)
Reveal
1/2″
■ 7877
■ 7878
■ 7897
120″
120″
120″
15/16″
15/16″
15/16″
15/16″
15/16″
15/16″
1/4″
3/8″
1/2″
Item #
■ 7835
(A)
Length
120″
(B)
Flange
7/8″
(C)
Height
1-3/4″
Flange
9/16″
B
A
B
C
C
A
C
B
A
PRELUDE ® XL
15/16" Exposed Tee System
Maximum Fixture Weight
Material
Hot dipped galvanized steel
LIGHT FIXTURE
63.32 lbs.
CROSS TEES
MINIMUM LBS. TO PULL OUT
COMPRESSION/TENSION
•
330.0
•
7301, 8301
20″ x 60″
60″ x 60″
43.21 lbs.
56.47 lbs.
65.46 lbs.
LIGHT FIXTURE
•
• •
•
▲
•
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item XL8340/XL7340
4. Item XL7342
5. Item XL8341/XL7341
MINIMUM LBS. TO PULL OUT
COMPRESSION/TENSION
335.0
24″ x 48″
60″ x 60″
48″ 48″
56.47 lbs.
Main Beams tested as follows: 7300 tested at 13.0 lbs./LF to 1/360 of 4′ span; 7301 tested at 16.5 lbs./LF to
1/360 of 4′ span.
Main beams
Hanger Wire (•)
Seismic Performance
7300, 7302, 7305,
734032, 8300
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7305
Item 7301/8301
B. Cross Tee to Cross Tee
16.59
9.00
8.31
7.61
7.61
12.12
12.23
•
1-1/2″
1-1/2″
1-3/8″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
•
47.17 lbs.
100.0 lbs.
•
•
48″
48″
48″
60″
60″
96″
72″
HANGER SPACING
Lbs./LF. (Simple Span)**
4′
40.45
40.45
33.0
40.45
40.45
61.33
16.54
23.11
6.0
12.25
12″ x 48″
48″ x 48″
•
•
WEB
HEIGHT
1-3/8″
1-3/8″
1-3/16″
1-3/8″
1-3/8″
1-11/16″
1-3/8″
1-11/16″
1-3/16″
1-11/16″
MAIN BEAMS
12″ x 48″
48″ x 48″
48″ 48″
54.26 lbs.
•
LENGTH
12″
20″
24″
24″
24″
24″
30″
36″
48″
48″
•
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7302
Item 7301/8301
Cross Tee Load Test Data
CROSS
TEES
XL7318/312451
XL7368
XL7128
XL7328/312051
XL8323/832052
XL8320
XL7378
XL7330
XL7148
XL8340/833033/
XL7340
XL7341/XL8341
XL7342
XL7348/313051
XL7357
XL7358
XL7380
XL7390
•
•
ASTM
CLASS
Intermediate-duty
Heavy-duty
Intermediate-duty
Intermediate-duty
Heavy-duty
Intermediate-duty
Intermediate-duty
72.32 lbs.
•
HANGER SPACING
Lbs./LF. (Simple Span)**
4′
5′
12.8
6.35
16.5
8.73
12.8
6.35
12.8
6.35
16.5
8.73
12.8
6.35
12.8
6.35
100.0 lbs.
•
•
Main Beam Load Test Data
24″ x 48″
48″ x 48″
48″
49.27 lbs.
•
Duty Classification
Intermediate or Heavy-duty
24″ x 48″
48″ x 48″
48″
69.27 lbs.
•
End Detail
Main Beam: Staked-on clip
XL Cross Tee: Staked-on clip
•
•
Cross Tee/Main Beam Interface
Override
WEB
HEIGHT
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
1-11/16″
•
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item 7300/8300
7302
Item 7301/8301
Profile
Exposed tee
LENGTH
144″
144″
144″
144″
144″
120″
140″
•
▲
Main Beam
Hanger Wire (•)
Face Dimension
15/16″
MAIN
BEAMS
7300
7301
734032
8300/834033
8301
7302
7305
•
A. Main Beam to
Main Beam
Surface Finish
Baked polyester paint or anodized
•
•
Physical Data
All XL cross tees exceed 300 lbs. in both compression and tension.
• •
24″ x 48″
48″ x 48″
48″
69.27 lbs.
40.89 lbs.
81.67 lbs.
•
24″ x 24″
48″ x 48″
48″
80.55 lbs.
52.26 lbs.
100.0 lbs.
•
• •
•
•
• •
•
ICC Reports
For areas under ICC jurisdiction, see ICC evaluation report number 1308 for allowable
values and/or conditions of use concerning the suspension system components listed on
this page. The report is subject to reexamination, revisions and possible cancellation.
**To derive maximum lbs/SF, divide the on-center spacing of the component into the lbs/LF given in the
load test data table.
1. Fixture*
2. Planning Module
3. Hanger Spacing
4. Item XL8340/XL7340
5. Item XL8341/XL7341
24″ x 48″
48″ x 48″
48″
49.27 lbs.
72.32 lbs.
12″ x 48″
48″ x 48″
48″
42.17 lbs.
63.32 lbs.
*Fixtures weighing more than 56 lbs. should be independently supported. Fixture weight is based on single fixture
only. For end-to-end fixtures or other configurations not shown, consult your Armstrong representative.
NOTE: The above data is based on 48″ hanger wire spacing, board weight of 1 lb./SF, maximum deflection of tees
not to exceed 1/360 of the span, and suspension system installed in accordance with ASTM C636.
TechLineSM / 1 877 ARMSTRONG
1 877 276 7876
armstrong.com/ceilings
CS-3344-809
LEED® is a registered trademark of the U.S. Green Building Council
© 2009 AWI Licensing Company • Printed in the United States of America
ULTIMA ®
Vector ®
10-YEAR
fine texture
Item 1920
Availability
Ultima Vector with Prelude ® 15/16" Exposed Tee grid (Pg. 215); Drywall Grid Soffit (Pg. 253)
Key Selection Attributes
• Smooth, clean, durable finish –
Washable, Scratch-resistant,
Soil-resistant
• 1/4" reveal resulting in a monolithic
appearance
• Downward accessible for minimal
plenum height
• Excellent sound absorption
Color
White (WH)
Typical Applications
• Visual coordinates with Optima® for mixed
(open/closed plan) applications
• Now available with Ultima® Create!™ custom
colors and images
• Smaller size panels available (1 carton min.
order). Info: armstrong.com/specials
• 30-Year Limited System Warranty against
visible sag, mold/mildew, and bacterial growth
Building owners/facility managers:
Call 1 877 ARMSTRONG for Optima/Ultima Vector Building Owner’s Kit,
CS-3398 (post-installation care and information)
• Offices
• Healthcare – assists in addressing
HIPAA and FGI acoustical requirements
• Corridors
• Lobbies/reception areas
• Building renovation
Optima/Ultima® Vector
Optima/Ultima
Vector
Accessories
Accessories Placement
Placement
Diagram
Diagram
For Contractors
Call 1 877 ARMSTRONG for Vector Contractor’s Kit, CS-3562
(installation tips and instructions)
r
cto
lip
rC
rde
Bo
Ve
St
ab
r
Ke
a
rB
ize
e
bil
dg
Sta
”E
“A
Detail
rfe
Ke
d
rfe
Ke
Ultima
Vector
187
s
ge
Ed
old
r H ips
cto Cl
Ve own
D
Ultima Vector with
Prelude 15/16"
Exposed Tee grid
TechLineSM 877 ARmSTRONG
“C
e
dg
”E
d
dE
e
dg
er
dg
Ba
r
es
e
dg
”E
“B
ge
d
”E
“D
iliz
dE
”E
“A
s
ge
rfe
A
B
All “A” edges must have Hold Down clips
No Hold Down clip should touch a “C” or “D” edge
armstrong.com/ceilings (search: ultima)
ULTIMA
Vector
Recycled
Content:
®
Classic Step Tegular
Ultima Plank ShipLap
Long Edge Detail
Linear Cubic
B
Beveled Crossgate
A
B
15/16" Vector
✔
✔ ✔
✔
Location Dependent
✔
Acoustics Low Emitting
or CHPS
✔
✔
$$$$$
Ultima Plank ShipLap
K2C2 Short
Ultima
VUltima
iLong
s uPlank
a ShipLap
l S e l e cBeveled
t i oPlank
n ShipLap
Edge Detail
Tegular Short
Performance Selection
15/16 Classic Step Tegular
~8-ID (99) (drw 10)
Dots represent highest level of performance.
Grid
Ultima Plank ShipLap
15/16 Classic Step Tegular
UL Classified
Drawings
~8-ID (99) (drw 10)
Beveled Tegular Short
AcousticsFire
Light Sag
Anti- Durable
Cat. pgs.
Edge
Item Dimensions
NRCCAC Rating
Reflect Resist
Microbial
226-228
Profile
or armstrong. No.
15/16" Square Tegular
9/16" Wrapped Tegular
and Cubic
9/16" Wrapped Tegular
1/4" Reveal
1921
1' x 2' x 3/4"
N/A N/A
Class A
Graphis Wrapped Linear20
and Cubic
B
C
C 15/16" VectorD
15/16" Vector C & D
C
D
15/16" Vector C & D
0.90
HumiGuard+ BioBlock+ Wash Scratch Soil
• • •
•
•
•
Yes
•
D
20
1920*
2' x 2' x 3/4"
A
B
C
D
Recycle
Program
com/catdwg
Graphis Wrapped Linear
ULTIMA Vector
A
0.70 33
Class A
•
0.90
• • •
•
•
•
•
* Ultima® Create!™ custom images and colors available for this item (see Ultima Create! Brochure CS-4374 for details). armstrong.com/ceilings (search: ultimacreate)
Suspension Systems
15/16"
9/16" Cubic Graphis
NeoCubic
Concealed
Soft Look Radiused Tegular
Prelude ®
Concealed
Soft Look Radiused Tegular
Accessories
Vec t or – Fi x t u r e T r i m s
(ordered separately)
Item #
440
Vector Border Clip
(For all installations)
Item #
Length
Color
Substrate
5790
1'
White
Extruded PVC
442 Vector Hold Down Clip
(For all installations)
5791
2'
White
Extruded PVC
7425
2' Stabilizer Bar
5792
30"
White
Extruded PVC
7445
4' Stabilizer Bar
5793
4'
White
Extruded PVC
7870
Spring Border Clip
(For installations with the panel resting on the wall molding)
000000
Printed on recyclable paper
with vegetable-based inks. Please Recycle.
A
Mgmt
✔
Local Renewable Daylight
Content Materials Materials & Views
Ultima Plank ShipLap
K2C2 Short
9/16" Square Cut Tegular
15/16" Square Tegular
LEED for Schools
Energy Waste Recycled
Ultima Plank ShipLap
Long Edge Detail
Ultima Plank ShipLap
Long Edge Detail
armstrong.com/greengenie
LEED® Credits
®
fine texture
15/16" Angled Tegular
70%
Physical Data
Surface Finish
DuraBrite with factory-applied latex paint
Fire Performance
ASTM E84 and CAN/ULC S102 surface burning
characteristics. Flame Spread Index 25 or less.
Smoke Developed Index 50 or less. (UL labeled)
ASTM E1264 Classification
Type IV, Form 2, Pattern E
Fire Class A
Sag Resistance
HumiGuard ® Plus – superior resistance to sagging in
high humidity conditions up to, but not including,
standing water and outdoor applications.
VOC/Formaldehyde Emissions
Meets CA Dept. of Health Services Standard Practice
for the testing of VOC Emissions depending on ceiling
use and building parameters. Contact TechLine to
evaluate performance.
Anti Mold/Mildew & Bacteria
BioBlock ® Plus contains an anti-microbial treatment and
provides guaranteed resistance against growth of
mold/mildew and Gram-positive and Gram-negative
odor/stain-causing bacteria for 30 years.
30-Year Performance Guarantee & Warranty Information
Details in back of catalog or at armstrong.com/warranty
Application Considerations
Product is directional. 1' x 2' products are intended for
use with 1' x 2' recessed lighting fixtures, and are not
UL Classified for acoustics.
Vector ceiling systems have been independent laboratory
tested for seismic performance.
Weight; Square Feet/Carton
1920 – 1.08 lbs/SF; 48 SF/ctn
1921 – 1.08 lbs/SF; 24 SF/ctn
Insulation Value
R Factor – 2.2 (BTU units)
R Factor – 0.39 (Watts units)
SM
TechLine / 1 877 ARmSTRONG
armstrong.com/ceilings (search: ultima)
CS-3313-1111
LEED® is a registered trademark of the U.S. Green Building Council
All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2011 AWI Licensing Company • Printed in the United States of America
188
M i n eral F iber
Material
Wet-formed mineral fiber with DuraBrite ® acoustically
transparent membrane
Ceiling&Wall
Sys tems
Between us, ideas become reality™
WOODWORKS ® Grille
WOODWORKS ® Grille
Backer and Dowel
Key Selection Attributes
• Define spaces with warm, natural solid wood
• Install in the ceiling, on the wall, or create 90º angled or faceted
ceiling-to-wall transitions
• Two blade sizes available in four rich finishes
• Easy installation with dowel or backer
• Excellent sound absorption with acoustical infill panel (NRC 0.75)
• Suspension system and panels from the same manufacturer
• Shorter lead times and lower cost than custom millwork
• Custom blade sizes and finishes available
• Custom curved application available with flexible backer
WoodWorks Grille Faceted Ceiling-to-Wall Transition 2-1/4" panels
in Grille Light Cherry with Backer
Finish Selection Grille
Maple
(GMP)
Grille
Light Cherry
(GLC)
WoodWorks Grille Ceiling 2-1/4" panels in Grille Walnut
with Backer; Samsung, Ridgefield Park, NJ
Due to printing limitations, shade may vary from actual product.
Grille
Dark Cherry
(GDC)
Grille
Walnut
(GWN)
Grilles Panel Backer
System Installation Details
360º Painted
Suspension
System in Black
2-1/4" Blade
Dowel
Ceiling Dowel Assembly
Wall
360º Painted
Suspension
System in Black
Dowel Clip
Grille
Panel
Furring
Strips
1-3/8" Blade
Backer
Clip
Ceiling Backer Assembly
Pictured on cover: WoodWorks Grille Ceilings Custom 3-1/4" Blades in Grille Light Cherry
on Prelude® HD grid in Black; Southern California Telemedicine Learning Center,
University of California San Diego School of Medicine, La Jolla, CA
Backer
Grille
Backer
Screws
Wall Backer Assembly
In addition to these standard options, there are more finish,
size, and curved design choices available as custom options.
Contact the Armstrong Architectural Specialties Project
Management Team for details at 1 877 ARMSTRONG and
select prompts 1-1-4.
Fire Performance – Solid Wood
Reported Flame Spread Indices
Code Classification Ranges
Flame Example
Class Spread Range Locations
Material1
I or A 0-25 II or B 26-75 III or C 76-200 and areas
Ash
Birch, Yellow
Cedar, Alaska Yellow
Cedar, Pacific Coast Yellow
Cedar, Port Orford
Cedar, Western Red
Cedar, Western Red
Cherry 3/4"
Cottonwood
Cypress
Elm 3/4"
Fir, Douglas
Fir, Douglas 3/4" flooring
Fir, Amabilis (Pacific Silver)
Fir, White
Gum, Red
Hemlock, West Coast
Larch, Western
Maple (flooring)
Oak, Red, or White
Oak, Red 3/4"
Enclosed
vertical exits
Exit access
corridors
Other rooms
Solid wood is widely used in interior
wall, ceiling, and floor surfaces in
all types of buildings.
Appearance, acoustical qualities,
and interior design versatility have
made wood surfaces highly desired
by architects, designers, and
building occupants.
This chart briefly shows building
code flame spread regulations on
products used as interior finishes
and presents performance data
on a range of wood products.
Reference sources are noted.
Always reconfirm ASTM compliance
on a project-by-project basis.
ASTM E84
Flame Spread 2
Source3
80
105-110
50
78
60
70
73
76
115
145-150
76
70-100
83-98
69
65
140-155
60-75
45
104
100
84
HPVA
UL
HPVA2
CWC
HPVA2
HPVA
CWC
HPVA
UL
UL
HPVA
UL
WEY
CWC
HPVA2
UL
WEY, UL
HPVA2
CWC
UL
HPVA
Lumber
Material1
ASTM E84
Flame Spread 2
Source3
77
84
85
72
82
150
120-215
115
142
130-195
95
75
170-185
70
102
55
65
74
100
130-140
101
HPVA
HPVA
CWC
HPVA
WEY
HPVA
UL
HPVA2
CWC
UL
HPVA2
UL
UL
UL
UL
HPVA2
UL
CWC
UL
UL
HPVA
Lumber
Oak, White 3/4"
Pecan 3/4"
Pine, Eastern White
Pine, Idaho White
Pine, Idaho White
Lauan 1/4"
Pine, Northern White
Pine, Ponderosa
Pine, Red
Pine, Southern Yellow
Pine, Sugar
Pine, Western White
Poplar, Yellow
Redwood
Redwood 3/8"
Spruce, Engelmann
Spruce, Northern
Spruce, Sitka
Spruce, Western
Walnut
Walnut 3/4"
1 Thickness of material tested is one-inch nominal except where indicated.
2 The ASTM E84 test method has been revised a number of times during the years referenced by the source reports. However, the E84 test apparatus has changed little
over this period. Slightly different flame spread indices, usually lower, result when recent E84 flame spread calculation techniques are applied to older wood product
data. These changes in flame spread indices are not sufficient to change the flame spread class for the wood products described in this report.
3 Sources:
APA – APA-The Engineered Wood Association, Research Reports 128, Revised, August 1979.
APA2 – APA-The Engineered Wood Association Test Results.
CWC – Fire Safety Design in Buildings, Canadian Wood Council, 1996.
HPVA – Hardwood Plywood and Veneer Association, Test Reports, 202, 203, 335, 336, 337, 592, and 596; Special flame spread performance tests, August 1974;
T9234, T9237, T9317, T9344, T9354, May 1995; T9422, T9430, T9431, T9453, T9665, February/July 1997.
HPVA2 – Hardwood Plywood and Veneer Association, March/April 1995; October/December 2000; June 2008.
NIST – National Institute of Standards and Technology (formerly National Bureau of Standards), Technical Notes 879 and 945.
UL – Underwriter's Laboratory, UL 527, May 1971; Subject 723, Assignment 71SC509, March 15 & 16, 1971; Assignment 84NK1898, File R10917, March 9, 1984.
WEY – Weyerhaueser Fire Laboratory, 1973, 1987, January & February 1988.
NOTE: While effort has been made to ensure the accuracy of the information in this publication, the American Forest & Paper Association, Armstrong World Industries, and
the Companies and Associations identified do not assume responsibility for the accuracy of the indices reported, the applicability or extension of the reported flame spread
values to specific products, or their acceptance for use in particular applications. Includes updates through June 2008.
Copyright © 1997, 1998, 2001, 2002, 2008 American Forest & Paper Association, Inc.
Acoustical Performance
Noise Reduction Coefficient, or NRC, is
a measure for rating the overall sound
absorption of a material when used in an
enclosed architectural space such as an
office, where sound is reflected at many
angles of incidence. WoodWorks® Grille
has an NRC value of 0.75 when installed
with a BioAcoustic™ infill panel.
NRC is important in any closed space where reverberation time and noise
levels are an issue:
• Closed offices, conference rooms
• Mixed plan office
• Lobby, reception, and work areas
• Classrooms/core learning areas, gymnasiums, cafeterias
• Retail spaces; checkout and other customer contact areas
Factors that may affect the installed acoustical performance relative
to the published results are:
• Size of area
• Number of panels
• Layout of panels
• Suspension distance below exposed deck or finished ceiling
Ceiling
Exposed
Structure
(No Ceiling)
Ultima
(100% Ceiling)
WOODWORKS
Grille
(100% Ceiling)
Reverberation Time
(RT)
3.4 seconds
0.5 seconds
0.5 seconds
RT
Improvement
N/A
85%
85%
Background Noise
Reduction
in Decibels (dB)
N/A
4.7dB
5.8dB
* You can calculate the acoustical difference that WoodWorks Grille panels can make in
your space by using our online Reverb Calculator Tool at armstrong.com/reverbtool
armstrong.com/greengenie
WOODWORKS ® Grille
LEED® Credits
Backer and Dowel
LEED for Schools
Energy Waste Recycled
Mgmt
Acoustics Low Emitting
Local Renewable Daylight
Content Materials Materials & Views
✔
✔
or CHPS
✔
Location Dependent
Finishes
Grille Maple (GMP)
Grille Light Cherry (GLC)
Grille Dark Cherry (GDC)
Grille Walnut (GWN)
Performance Selection
V i s u a l S e l e c t i o n Edge
Profile
Item
Number
Dots represent highest level of performance.
Description
◆◆
Acoustics
NRC*
Dimensions
Nominal W x L x H
95.000
12.000
WoodWorks Grille – Backer and Dowel
.875
.500
Backer
5663_ _ _ _ _ ◆
12.000
n .500
2.75
875
5664_ _ _ _ _
95.000
◆
1-3/8" 6 blades
1' x 8' x 1-7/8" with Backer
1' x 8' x 1-3/8" with Dowel
0.75
1-3/8" 8 blades
1' x 8' x 1-7/8" with Backer
1' x 8' x 1-3/8" with Dowel
0.75
2-1/4" 6 blades
1' x 8' x 2-3/4" with Backer
1' x 8' x 2-1/4" with Dowel
0.75
2-1/4" 8 blades
1' x 8' x 2-3/4" with Backer
1' x 8' x 2-1/4" with Dowel
0.75
12.000
5.500
.6875
FRONT
Dowel
SCALE 1 / 25
5665_ _ _ _ _
.625
2.000
2.250
•
TOP
◆
12.000
SCALE 1 / 4
•
5666_ _ _ _ _
◆
5.500
TOP
•
•
SCALE 1 / 25
W
hen specifying
or ordering Backer or Dowel panels, please include the installation type and color suffixes (e.g., 5663 B O G L C – 6 blades 1-3/8" Backer in Grille Light Cherry).
.625
SCALE 1 / 4
Installation suffixes:
BO = Backer, DO = Dowel
2.000
* N RC 0.75 with acoustical infill Item 5823.
N OTE: For additional color and size options, as well as curved applications requiring flexible Backers available as special order, call Architectural Specialties at 1 877 ARMSTRONG
and select options 1-1-4.
FRONT
1.6875
◆
Suspension Systems
15/16"
Prelude ® XL ® (Black recommended), 360º Painted with 4' cross tee route holes at 12"
15/16"
Serpentina ® Main Beam (for use with Flexible Backers) in Black
Note: For ceilings with a radius of 12-1/2' or greater, use standard panels and 15/16" main beams faceted 12" on center with RC2BL clips.
Accessories
Item Number
.191
5687
.210
.897
.125
.188
.191
n .100
5688
.200
.935
.020
R.010
Description
Dimensions
Nominal W x L x H
Color
Pieces/Carton
Backer Clip
3/8" x 11/16" x 7/8"
N/A
250 pcs/pail
Dowel Clip
3/8" x 7/8" x 7/8"
N/A
250 pcs/pail
Ledger
1" x 96" x 1/4"
See Finishes Above
Bulk
n .100
12 Ga.
Hanger
Wire
Wall
1.015
.125
125°
5671 _ _ _**
R.020
115°
.087
.445
.583
85°
.020
e5
Flat Pattern
SCALE 1 : 1
.375
.888
115°
55°
e1
1.066
.707
R.020
.883
e1
.188
.883
11° 2
e
e4
Junction – 1-3/8"
1-1/2" x 96" x 2"
See Finishes Above
Bulk
5673 _ _ _**
Junction – 2-1/4"
1-1/2" x 96" x 2-3/4"
See Finishes Above
Bulk
5674 _ _ _**
End Cap – 1-3/8"
3/4" x 96" x 2"
See Finishes Above
Bulk
5675 _ _ _**
End Cap – 2-1/4"
3/4" x 96" x 2-3/4"
See Finishes Above
Bulk
7891
12 Gauge Soft Hanger Wire
12' Length
N/A
140
92715A620
Self-tapping Screws
#2 x 3/4" Length
Black
25
6459BL
Uptight Clip
5-1/2" x 1-3/4"
Black
25
RC2BL
RC2 Radius Clip
N/A
Black
205
5823
BioAcoustic ™ Infill Panel
2' x 2' x 5/8"
Black (Matte)
10
5672 _ _ _**
.087
.188
FLAT PATTERN
SCALE 1 : 1
R.275
e3
.375
**
W hen specifying or ordering, include the three-letter color suffix that coordinates with your WoodWorks ceiling: (e.g., 5671 G M P)
Rigid Attachment
Clip 6459BL
Serpentina
Main Beam
Grille Blades with
Flexible Backer
Furring Strip
WoodWorks Grille
Ceiling-to-Wall Transition
Installation Detail
Physical Data
Material
Blades and Backers – solid poplar
Dowel – solid birch
Surface Finish
Clear or tinted semigloss coating
Fire Performance
Solid Poplar Hardwood Blades and Backers – ASTM E84
surface burning characteristics. Flame Spread Index 200
or less. Smoke Developed Index 450 or less.
Solid Birch Hardwood Dowels – ASTM E84 surface burning
characteristics. Flame Spread Index 200 or less. Smoke
Developed Index 450 or less.
For improved Flame Spread performance, intumescent
treatment is available.
Fire performance will vary between wood species.
Composite Grille product testing has not been completed,
since results will vary on a project-by-project basis.
Contact TechLine at 1 877 ARMSTRONG for details.
SM
TechLine / 1 877 ARmSTRONG
armstrong.com/woodworks
CS-4111-1211
Woodworks Grille, as with other architectural features
located at the ceiling, may obstruct or skew the planned
fire sprinkler water distribution pattern, or possibly delay
or accelerate the activation of the sprinkler or fire detection
systems by channeling heat from a fire either toward or
away from the device. Designers and installers are advised
to consult a fire protection engineer, NFPA 13, and local
codes for guidance where automatic fire detection and
suppression systems are present.
Seismic Restraint
WoodWorks Grille has been engineered, tested, and
approved in all seismic areas.
Application Considerations
Variation among panels may occur due to the natural
characteristics of the wood and grain.
Design Considerations
For blade heights over 5", both Dowels and Backers
are required for stability. Blade sizes over 2-1/4" are
not recommended for wall applications. Contact the
Architectural Specialties Project Management team
for details at 1 877 ARMSTRONG and select options 1-1-4.
It is very important that WoodWorks panels are climatized
prior to installation. Relative humidity between 25% and
55% and temperatures between 50˚F and 86˚F must be
maintained.
Installation Consideration
When junction accessory is not used, leave 1" gap between
blade lengths.
Warranty
One (1) year limited warranty. Details: armstrong.com/warranty
Weight; Square Feet/Carton
5663 – 2.0 lbs/SF
5664 – 2.6 lbs/SF
5665 – 2.8 lbs/SF
5666 – 3.6 lbs/SF
LEED® is a registered trademark of the U.S. Green Building Council
All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates
© 2011 AWI Licensing Company • Printed in the United States of America