HVB Data Sheet

advertisement
IP66 & IP67
Zone 1, 2, 21, 22
HVB Series Enclosures
2E
Sheet or Stainless Steel
High Voltage Junction Box
Features/Applications:
• The high voltage enclosures have been designed for the termination of high
voltage pumps ("down hole" pumps)
• The HVB’s are available in both stainless steel, fully polished or sheet steel
with paint finish
• Gland plates are provided top and bottom for cable entry
• The units are complete with 3 or 4 pole assemblies to accept standard cable
lugs up to 1.18" wide and an M12 hole
• Live parts are protected by a clear cover, giving protection to IP 2X
• High voltage warning labels are fitted to the cover and enclosure cover
• When using the enclosures at their full potential (i.e. 6.6 kV), high voltage cable
termination kits have to be used to avoid breakdown of the cable long term
Certifications and Compliances:
II 2 G Ex e II T6, T5, or T4 ATEX (Baseefa03ATEX0052X) Ex'e' II T4 200A, T5 180A, T6160A
UL50/C22.2 No. 94-M91 mild steel: Types 3S, 4; stainless steel: Type 4X
Specifications:
Description
Material
Type
Specification
HVB 463820
HVB 765120, 916120
Gland Plates
Stainless steel grades: standard is 316L (1.4401) & 304 on request (1.4301) or sheet steel
2E
Finish
Gasket
Painted RAL 7032
Stainless Bright Chemical Dip (polished appearance)
Neoprene (cover & gland plates)
Cover Mounting
Fully detachable hinged cover with 4 or 6 x M6 hexagon head captive screws
Grounding
Box Mounting
M10 internal/external stud
M14 internal/external stud for 5.91in2 phase conductor only
4 x external lugs with 0.39" clearance holes/slots
Ingress Protection
IP66 & IP67 to IEC 529
Temperature Range
–4°F to 104°F (ambient)
Impact Resistance
7 J (Nm)
Gland Plates
Top & Bottom
Ratings
6.6 kV 50Hz* ac 3 phase (grounded or ungrounded supply systems)
Voltage
*At frequencies above 50 Hz, current carrying capacities may require derating (e.g. motor variable speed controllers).
Maximum Current Rating (Amps):
To allow American Wire Gauge (AWG) cables and current ratings for T6 to T4 temperature classes.
Conductor Size
Current A
AWG (max. 5.91in2)
T6 (185°F)
T5 (212°F)
T4 (275°F)
6
4
3
2
1
1/0
2/0
3/0
42
55
64
73
81
101
150
160
59
80
92
107
121
141
173
180
65
88
102
118
134
156
192
200
Maximum Wiring Space for HV Cable Termination Kits:
Enclosure Type
HVB 463820
HVB 765120
HVB 916126
Distance Between Bolt & Gland Plate
7.09"
13.19"
16.14"
Connections:
3 or 4 pole, consists of 6 or 8 post insulators with 0.24" brass busbars, tin lead plated. Cable alignment restrictors prevent misalignment of
the conductors. Accepts standard cable lugs up to 1.18" wide and an M12 hole.
782
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
IP66 & IP67
Zone 1, 2, 21, 22
HVB Series Enclosures
2E
Sheet or Stainless Steel
High Voltage Enclosures
Ordering Information
Dimensions
In Inches:
HVB765120 (3 pole)
2E
HVB463820 (3 pole)
A = Top
B = Bottom
For dimensions marked with a * subtract 1.18" for 2 gland plate versions.
HVB463820 (3 pole)
HVB765120 (3 pole)
Height
Width
Depth
Weight
Height
Width
Depth
Weight
18.03"
15.04"
7.87"
52.36 Ib
30"
20"
7.87"
81.57 Ib
Ordering Data:
Type
Description
Cat. #
Cat. #
M10 Ground Stud Phase
Conductor 4.72in2 Max.
M14 Ground Stud Phase
Conductor 5.91in2 Only
Standard Paint Finish
Stainless Steel Finish
Standard Paint Finish
Stainless Steel Finish
HVBPS463820M10
HVBS1463820M10
HVBPS463820M14
HVBS1463820M14
HVBPS765120M10
HVBS1765120M10
HVBPS765120M14
HVBS1765120M14
Description
HVB463820
Side
Size
HVB765120
Side
Size
Max. Gland Area Dimensions
A+B
A+B
Guide to Gland Entries:
13.27" x 4.25"
18.27" x 4.25"
Gland Sizes (mm) Brass (Per Plate):
Size
HVB463820
HVB765120
40
50
63
75
6
4
3
3
8
6
4
4
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
783
2E
IP66 & IP67
Zone 1, 2, 21, 22
HVB Series Enclosures
Sheet or Stainless Steel
High Voltage Enclosures
Ordering Information
Dimensions
In Inches:
HVB916120 (3 pole)
HVB916120 (4 pole)
A = Top
2E
B = Bottom
For dimensions marked with a * subtract 1.18" for 2 gland plate versions.
HVB916120 (3 pole)
HVB916120 (4 pole)
Height
Width
Depth
Weight
Height
Width
Depth
Weight
35.98"
24.20"
7.87"
99.21 Ib
35.98"
24.02"
7.87"
103.62 Ib
Ordering Data:
Type
Description
Cat. #
Cat. #
M10 Ground Stud Phase
Conductor 4.72in2 Max.
M14 Ground Stud Phase
Conductor 5.91in2 Only
Standard Paint Finish
Stainless Steel Finish
Standard Paint Finish
Stainless Steel Finish
HVBPS916120M10
HVBS1916120M10
HVBPS916120M14
HVBS1916120M14
HVBPS916120M104P
HVBS1916120M104P
HVBPS916120M144P
HVBS1916120M144P
Description
HVB916120 (3 pole)
Side
Size
HVB916120 (4 pole)
Side
Size
Max. Gland Area Dimensions
A+B
A+B
Guide to Gland Entries:
22.28" x 4.25"
22.28" x 4.25"
Gland Sizes (mm) Brass (Per Plate):
Size
HVB916120 (3 pole)
HVB916120 (4 pole)
40
50
63
75
8
7
5
4
8
7
5
4
784
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business