IP66 & IP67 Zone 1, 2, 21, 22 HVB Series Enclosures 2E Sheet or Stainless Steel High Voltage Junction Box Features/Applications: • The high voltage enclosures have been designed for the termination of high voltage pumps ("down hole" pumps) • The HVB’s are available in both stainless steel, fully polished or sheet steel with paint finish • Gland plates are provided top and bottom for cable entry • The units are complete with 3 or 4 pole assemblies to accept standard cable lugs up to 1.18" wide and an M12 hole • Live parts are protected by a clear cover, giving protection to IP 2X • High voltage warning labels are fitted to the cover and enclosure cover • When using the enclosures at their full potential (i.e. 6.6 kV), high voltage cable termination kits have to be used to avoid breakdown of the cable long term Certifications and Compliances: II 2 G Ex e II T6, T5, or T4 ATEX (Baseefa03ATEX0052X) Ex'e' II T4 200A, T5 180A, T6160A UL50/C22.2 No. 94-M91 mild steel: Types 3S, 4; stainless steel: Type 4X Specifications: Description Material Type Specification HVB 463820 HVB 765120, 916120 Gland Plates Stainless steel grades: standard is 316L (1.4401) & 304 on request (1.4301) or sheet steel 2E Finish Gasket Painted RAL 7032 Stainless Bright Chemical Dip (polished appearance) Neoprene (cover & gland plates) Cover Mounting Fully detachable hinged cover with 4 or 6 x M6 hexagon head captive screws Grounding Box Mounting M10 internal/external stud M14 internal/external stud for 5.91in2 phase conductor only 4 x external lugs with 0.39" clearance holes/slots Ingress Protection IP66 & IP67 to IEC 529 Temperature Range –4°F to 104°F (ambient) Impact Resistance 7 J (Nm) Gland Plates Top & Bottom Ratings 6.6 kV 50Hz* ac 3 phase (grounded or ungrounded supply systems) Voltage *At frequencies above 50 Hz, current carrying capacities may require derating (e.g. motor variable speed controllers). Maximum Current Rating (Amps): To allow American Wire Gauge (AWG) cables and current ratings for T6 to T4 temperature classes. Conductor Size Current A AWG (max. 5.91in2) T6 (185°F) T5 (212°F) T4 (275°F) 6 4 3 2 1 1/0 2/0 3/0 42 55 64 73 81 101 150 160 59 80 92 107 121 141 173 180 65 88 102 118 134 156 192 200 Maximum Wiring Space for HV Cable Termination Kits: Enclosure Type HVB 463820 HVB 765120 HVB 916126 Distance Between Bolt & Gland Plate 7.09" 13.19" 16.14" Connections: 3 or 4 pole, consists of 6 or 8 post insulators with 0.24" brass busbars, tin lead plated. Cable alignment restrictors prevent misalignment of the conductors. Accepts standard cable lugs up to 1.18" wide and an M12 hole. 782 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business IP66 & IP67 Zone 1, 2, 21, 22 HVB Series Enclosures 2E Sheet or Stainless Steel High Voltage Enclosures Ordering Information Dimensions In Inches: HVB765120 (3 pole) 2E HVB463820 (3 pole) A = Top B = Bottom For dimensions marked with a * subtract 1.18" for 2 gland plate versions. HVB463820 (3 pole) HVB765120 (3 pole) Height Width Depth Weight Height Width Depth Weight 18.03" 15.04" 7.87" 52.36 Ib 30" 20" 7.87" 81.57 Ib Ordering Data: Type Description Cat. # Cat. # M10 Ground Stud Phase Conductor 4.72in2 Max. M14 Ground Stud Phase Conductor 5.91in2 Only Standard Paint Finish Stainless Steel Finish Standard Paint Finish Stainless Steel Finish HVBPS463820M10 HVBS1463820M10 HVBPS463820M14 HVBS1463820M14 HVBPS765120M10 HVBS1765120M10 HVBPS765120M14 HVBS1765120M14 Description HVB463820 Side Size HVB765120 Side Size Max. Gland Area Dimensions A+B A+B Guide to Gland Entries: 13.27" x 4.25" 18.27" x 4.25" Gland Sizes (mm) Brass (Per Plate): Size HVB463820 HVB765120 40 50 63 75 6 4 3 3 8 6 4 4 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 783 2E IP66 & IP67 Zone 1, 2, 21, 22 HVB Series Enclosures Sheet or Stainless Steel High Voltage Enclosures Ordering Information Dimensions In Inches: HVB916120 (3 pole) HVB916120 (4 pole) A = Top 2E B = Bottom For dimensions marked with a * subtract 1.18" for 2 gland plate versions. HVB916120 (3 pole) HVB916120 (4 pole) Height Width Depth Weight Height Width Depth Weight 35.98" 24.20" 7.87" 99.21 Ib 35.98" 24.02" 7.87" 103.62 Ib Ordering Data: Type Description Cat. # Cat. # M10 Ground Stud Phase Conductor 4.72in2 Max. M14 Ground Stud Phase Conductor 5.91in2 Only Standard Paint Finish Stainless Steel Finish Standard Paint Finish Stainless Steel Finish HVBPS916120M10 HVBS1916120M10 HVBPS916120M14 HVBS1916120M14 HVBPS916120M104P HVBS1916120M104P HVBPS916120M144P HVBS1916120M144P Description HVB916120 (3 pole) Side Size HVB916120 (4 pole) Side Size Max. Gland Area Dimensions A+B A+B Guide to Gland Entries: 22.28" x 4.25" 22.28" x 4.25" Gland Sizes (mm) Brass (Per Plate): Size HVB916120 (3 pole) HVB916120 (4 pole) 40 50 63 75 8 7 5 4 8 7 5 4 784 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business