Specification Grade Strips

advertisement
Specification Grade Strips
TM
Retail... Commercial... Institutional... Hospitality... Residential... Industrial
2
Versatile
Strips are the most versatile luminaires in the lighting industry.
Applications are driven by one’s creativity, ranging from retail
to industrial projects. The elementary form-follows-function
design makes this product an ideal lighting instrument to incorporate into architectural features such as coves, slots, millwork
and decorative elements.
CONTENTS
Product Features
Photometry
Product Matrix
Specifications Applications
4-6
7
8-9
10-11
14-15
3
Product Features
1 Die formed, 20 gauge cold rolled steel housing and 16 gauge cold rolled steel end caps.
2 High reflectance white electrostatically applied powder coat paint after fabrication.
2
5
7
6
4
1
3
8
Specification Grade Strips
3 Housing designed for specification electronic ballast and battery packs.
4 7/8” End knock-outs for easy wiring. Quick through wiring is optional.
5 Cover attaches with one screw for installation ease.
6 Rotary lamp holder for positive lamp retention, IEC rated.
7 UL / cUL listed. Damp location is optional.
8 Mounting feet for stability.
9 Multiple standard reflectors.
Consult factory for custom
reflectors.
T5
T5HO
T8
Integral Ballast
Remote Ballast
9
Staggered
Telescoping
Customs
Colors Available
Actual Size
4
5
Product Features
Telescoping
(SAL series)
Our telescoping 2-light strip is designed to fill-in
illumination at the end of a run or used individually
where adjustment is needed for a particular application. The luminaire can extend up to 12” and retract
6” or 3” when mounted individually.
Continuous Row
12” Adjustment
Individual Luminaire
6” Adjustment (T5)
3” Adjustment (T8)
12” Adjustment
Snap-on Lens
(FRS option)
The optional snap-on frosted lens is available for
one-light luminaires. The extruded frosted lens is
ideal for projects that require added lamp protection,
or to soften lamp brightness. The open end design
allows air flow around the lamp. A lens will be supplied
per lamp. For example, a nominal 8’ luminaire will
have two nominal 4’ lenses.
Emergency Battery Pack
(EM option)
Nulite designed the new specification grade strip
housing to accommodate reduced or low profile
emergency battery packs. Each luminaire with the
EM option is provided with an indicator light and
test switch located at the end of the housing. For
side-mount luminaires, the indicator light and test
switch are located in the ballast cover. Emergency
battery pack is not available in nominal 2’ units,
and consult factory for nominal 3’ units.
6
Photometry
Photometric data of our standard reflectors.
1377
1032
Cat. # SA-154T5HO...ASY*
688
344
Cat. # SA-154T5HO...SYM*
1377
1032
688
344
1377
1032
Cat. # SA-154T5HO...RASY*
688
344
* Initial lamp lumens - 5,000. Housing and solid reflector are finished with high reflectance white baked powder coat paint after fabrication.
7
Product Matrix
Nulite is a leader in specification grade fluorescent strips. We offer luminaires
in T5, T5HO or T8 lamping, integral or remote ballast configurations, with multiple standard reflectors and finishes. If you’re looking for a modification, give
us a call because customs are our niche.
Products
1-9/16”
3-1/16”
Integral Staggered
2 5/16"
3-3/4”
2 5/16"
2 1/4"
3 11/16"
2 5/16"
1 3/8"
2-5/16”
2-1/4”
2-3/8”
2-1/4”
1-1/2”
2-3/8”
1 3/8"
2 5/16"
3-1/16”
SA-2T5...
3-7/8”
SAT-1T5...
2 1/4"
2 5/16"
3-3/4”
2-3/8”
3-1/8”
3 7/8"
2-5/16”
2 5/16"
3-1/16”
3-7/8”
3 1/16"
3-3/4”
Integral
2 3/8"
3 1/8"
2 5/16"
2-5/16”
2-3/8”
2-5/16”
SA-1T5...
1-1/2”
2-1/4”
2-3/8”
1-5/8”
1-1/2”
1-1/2"
3 3/4"
2-3/8”
3-3/4”
Integral Staggered
1-1/2”
2-3/8”
1 9/16"
2-3/8”
1 1/2"
Integral
SAT-2T5...
3-7/8”
3 7/8"
3 1/16"
Integral Telescoping
1-1/2”
Integral Side Mount
1-1/2”
2-3/8”
3-3/4”
2-3/8”
3-3-/8”
2-1/4”
6”
SAL-2T5...
Integral Right Angle
Remote
2-3/8”
1-1/2”
2-3/8”
1-1/2”
8
SAC-_T5...
1-5/8”
1-1/2”
6”
2-3/8”
3-3/8”
4-1/8”
2-13/16”
2-3/8”
SAS-_T5...
2-5/16”
6-3/4”
SAR-1T5...
3-1/8”
3 11/16"
Product Matrix
Products
4-3/8”
1-1/2”
2-3/4”
1-1/2”
4-1/2”
Integral Staggered
2-3/4”
Integral
3”
2-7/8”
2-7/8”
2”
4-1/8”
Integral Staggered
2-3/4”
1-1/2”
5-1/8”
3”
1-1/2”
Integral
4-3/8”
SAT-1T8...
2-3/4”
SA-1T8...
4-3/8”
4-1/4”
3-1/8”
4-1/8”
2-7/8”
2-7/8”
3”
5-1/8”
SAT-2T8...
Integral Side Mount
Integral Telescoping
4-1/8”
5-1/8”
1-5/8”
1-3/4”
SA-2T8...
3-5/16”
2-3/4”
4-3/4”
3”
7-5/8”
SAL-2T8...
Integral Right Angle
Remote
1-3/4”
2-3/4”
SAS-_T8...
3-5/16”
2”
2-3/4”
7-5/8”
3-1/8”
SAC-_T8...
5-5/8”
2”
1-7/8”
4-5/8”
3-1/2”
4-5/8”
8-5/8”
SAR-1T8...
4-1/4”
9
T5 / T5HO
TM
SA-1T5...
SA-2T5...
SAR-1T5...
SAT-1T5...
SAT-2T5...
SAL-2T5...
SAS-1T5...
SAC-2T5...
Ordering Information
Sample: SA-154T5HO-UNV-PSN-DL-ASY
Series
Construction: Die formed 20 gauge cold rolled steel
housing and 16 gauge cold rolled steel end caps. The
housing is finished in high reflectance white baked polyester powder coat paint after fabrication. Optional aluminum
Lamp
or stainless steel housing.
Reflector / Housing: Reflector / ballast cover is finished
with high reflectance white baked polyester powder coat
paint after fabrication. Consult factory for custom reflectors.
Standard electronic, Class P, ballast.
Wattage
Lamping: T5 or T5HO. Luminaire can be ordered with
lamps, consult factory.
Mounting: Surface
Voltage
2-1/4”
2-1/4”
2-3/8”
2-3/8”
4-5/8”
Options
1-1/2”
1-1/2”
Ballast
2-3/8”
2-3/8”
2-3/8”
Labels: UL / cUL listed. Damp location is optional.
1-1/2”
2-1/4”
Length Chart
10
Wattage
SA, SAS, SAC
SAR
SAT-1
SAT-2
14T5, 24T5HO
22-1/2”
23-7/8”
22-1/2”
28-3/8”
21T5, 39T5HO
34-3/8”
35-5/8”
34-3/8”
40-3/16”
28T5, 54T5HO
46-1/8”
47-1/2”
46-1/8”
52-3/16”
21T5-6, 39T5HO-6
68-3/4”
N/A
62-3/4”
74-3/4”
28T5-8, 54T5HO-8
92-3/16”
N/A
86-1/4”
98-3/16”
Type:
Project:
Date:
Catalog #:
SA
SAR
SAT
SAL1
SAS
SAC
= Strip Architectural Integral
= Strip Architectural Remote
= Strip Architectural Staggered
= Strip Architectural Telescoping
= Strip Architectural Side-mount
= Strip Architectural Right Angle
1
2
32
2
4
14T5
21T5
28T5
21T5-6
28T5-8
UNV
120
277
3473
4803
24T5HO
39T5HO
54T5HO
39T5HO-6
54T5HO-8
= Universal (120 to 277V)
PSN = Program Start / Normal B.F.
HEPSN3 = High Efficiency Program Start / Normal B.F.
DIM3 = Dimming
SD3
= Step Dimming
EM4
AL
SS
DL
SYM
ASY
RASY
WG1
FRS5
QW
GLR
= Emergency Battery Pack
= Aluminum Housing
= Stainless Steel Housing
= Damp Location
= Symmetrical Reflector
= Asymmetrical Reflector
= Reverse Asymmetrical Reflector
= Wireguard
= Frosted Snap-on Lens
= Quick Through Wiring
= Fusing
Notes:
1. Consult factory for reflector options.
2. 3 or 4 lamp are only available for the SAC series.
3. Consult factory.
4. Emergency is not available for 2’ unit; consult factory for 3’ unit. Specific
voltage must be ordered for this option.
5. 1-Light cross-section only.
Specifications and dimensions are subject to change without notification. Visit www.nulite-lighting.com for the most up-to-date specification sheets which supersede all published versions.
Nulite
10770 East 51st Avenue, Denver, CO 80239
Phone 303-287-9646 Fax 303-287-0316
www.nulite-lighting.com
Ordering Information
Sample: SA-232T8-UNV-ISN-DL-SYM
Options
SAL-2T8...
SAS-1T8...
SAC-2T8...
Construction: Die formed 20 gauge cold rolled steel
housing and 16 gauge cold rolled steel end caps. The
housing is finished in high reflectance white baked polyester powder coat paint after fabrication. Optional aluminum
or stainless steel housing.
1
2
32
42
Reflector / Housing: Reflector / ballast cover is finished
with high reflectance white baked polyester powder coat
paint after fabrication. Consult factory for custom reflectors.
Standard electronic, Class P, ballast.
21T8
25T8
32T8
25T8-6
32T8-8
Lamping: T8. Luminaire can be ordered with lamps, consult
factory.
Mounting: Surface
Labels: UL / cUL listed. Damp location is optional.
= Universal (120 to 277V)
IS
PS
HEIS
HEPS
3
DIM 3
SD = Instant Start
= Program Start
= High Efficiency Instant Start
= High Efficiency Program Start
= Dimming
= Step Dimming
EM4
AL
SS
DL
SYM
ASY
RASY
WG1
FRS5
QW
GLR
= Emergency Battery Pack
= Aluminum Housing
= Stainless Steel Housing
= Damp Location
= Symmetrical Reflector
= Asymmetrical Reflector
= Reverse Asymmetrical Reflector
= Wireguards
= Frosted Snap-on Lens
= Quick Through Wiring
= Fusing
N = Normal B.F.
L = Low B.F.
H = High B.F.
2-3/4”
UNV
120
277
3473
3”
2”
4-5/8”
1-3/4”
Ballast
SAT-2T8...
2-3/4”
Voltage
SAT-1T8...
2-3/4”
Wattage
= Strip Architectural Integral
= Strip Architectural Remote
= Strip Architectural Staggered
= Strip Architectural Telescoping
= Strip Architectural Side-mount
= Strip Architectural Right Angle
SAR-1T8...
2-3/4”
Lamp
SA
SAR
SAT
SAL1
SAS
SAC
SA-2T8...
2-3/4”
Series
SA-1T8...
2”
3”
3”
Length Chart
Notes:
1. Consult factory for reflector options.
2. 3 or 4 lamp are only available for the SAC series.
3. Consult factory.
4. Emergency is not available for 2’ unit; consult factory for 3’ unit. Specific
voltage must be ordered for this option.
5. 1-Light cross-section only.
Wattage
SA, SAS, SAC
SAR
SAT-1
SAT-2
14T5, 24T5HO
24”
25-3/8”
24”
27”
21T5, 39T5HO
36”
37-3/8”
36”
39”
28T5, 54T5HO
48”
49-3/8”
48”
51”
35T5, 80T5HO
72”
N/A
69”
75”
28T5-8, 54T5HO-8
96”
N/A
93”
99”
Specifications and dimensions are subject to change without notification. Visit www.nulite-lighting.com for the most up-to-date specification sheets which supersede all published versions.
Nulite
T8
TM
Type:
Project:
Date:
Catalog #:
10770 East 51st Avenue, Denver, CO 80239
Phone 303-287-9646 Fax 303-287-0316
www.nulite-lighting.com
11
12
Integrate
The integration of lighting into
the architectural features gives
a space a cohesive feeling,
and creates visual interest in
the environment. Cove lighting is an ideal way to add an
indirect component for a layered illumination effect.
13
Applications
Cove Design Recommendations
NOTE:
Nulite recommends finishing the interior
surfaces matte white for maximum performance. The interior surfaces will reflect light
to minimize shadows and maximize light output. In addition, the illuminated surface should
have a matte finish to reduce lamp reflections
and socket shadows.
Light throw line
Cove
Lip Height
Critical sight line
Cove Width
e
row lin
Light th
Critical
Sig
ht
1. Determine the location of the cove and luminaire
for the particular application. Increasing the distance
from the illuminated surface improves the uniformity,
efficiency and throw distance but can affect the sight
line.
2. Determine the critical sight line in the space. Beware
of stairs, escalators and balconies. These features can
require greater than horizontal cutoff. The farthest visible
point can be in adjacent locations. The goal is to conceal
the lamp brightness from one’s field of view.
3. The intersection of the critical sight line and throw
line will determine the top of the cove lip.
4. Make sure there is adequate clearance around the
luminaire for installation and maintenance.
5. Leave adequate space at the ends of the run
(approximately 6”) for installation.
14
lin
sight lin
ei
e in adja
nh
all
wa
y
cent sp
ace
Retail... Commercial... Hospitality... Industrial... Residential... Institutional...
EVERYWHERE
Typical Applications
Commercial projects can have a custom
lighting appearance by incorporating strips
into simple details. For instance, a field
constructed valance provides an integrated
appearance and soft ambient illumination.
The integration of lighting into millwork can give
a retail space a high-end
appearance, and creates
visual interest.
A recessed perimeter ceiling slot
is an excellent way to increase
the visual size of the space and
highlight merchandise.
Industrial workspaces are ideal application for strips. The local
task lighting improves visibility for assembly and can reduce overall lighting energy consumption.
15
Specification Grade Strips
10770 East 51st Avenue
Denver, CO 80239
Phone 303-287-9646
Fax 303-287-0316
www.nulite-lighting.com
TM
Download