rg series - Lumax Lighting

advertisement
Job
Type
Catalog #
• High performance specification grade
lensed/louvered troffer.
Superior flexibility and efficiency for
commercial, retail and institutional
applications.
• Wide range of lens, louver, door
frame styles, lamp and ballast types
and air handling functions.
Finish
• All exposed metal parts
pretreated with a phosphate
bonding process and post
painted with an electrostatically
applied high temperature baked white
enamel for superior
quality and durability.
Electrical
• Standard ballast is electronic, hpf,
class p and ul listed for universal voltage.
listed.
listed
Series
Lmps
RG
2,3,4
2,3
2
2,3,4
2,3,4
2,3,4,6
slots. Optional control vanes.
• Designed for nema type g (grid).
• Consult factory for compatibility.
2x2, 2x4
High Performance
Lensed/Louvered
Troffers Static
Example: RG33224-CO1FARS
Watts
17-17w T8
14-14wT5
24-24wT5HO
Fixt
22
U2-31wU15/8c/c
U6-31w U6
4T-40wTwiTube
5T-50TwinTube
6T-55wTwiTube
28-28w T5
54-54wT5HO
32-32w T8
• Die-formed steel housing and ends exceed code
gauge. embossed for strength and uniformity.
heavy-duty ends attach to housing with interlocking tabs. built in eq clips.
• Slope-sided housing and ballast cover for
superior light control.
• Quick access plate for convenient power
connection.
• Door frames screw-assembled for rigidity and
ease of lens replacement. crisp mitered corners. available full, floating with black reveal
or heat removal in steel (flush) or aluminum
(flush and regressed).
• End light seals and side gaskets prevent any
light leakage around door frames.
• Rotary cam latches standard on full doors;
spring-loaded latch standard on floating doors
(optional on full doors). latching/hinging
reversible; door frame easily removed without
tools.
• Air models with floating doors available with
side slots, top slots or both. full door air
models available with end air baffles and top
• Suitable for damp locations.
• I.B.E.W. Labeled.
ORDERING GUIDE
RG
SERIES
Construction
Application
24
Air Function:
T - Top
S - Side
C - Top and Side
VANES:
V - Vanes
Ballasts:
1 or 2 lamps:
EO – one ballast
3+ lamps:
EO – two ballasts, wired inboard/outboard
(or customer specified)
CO – one ballast
Specific Ballasts:
HL – high ballast factor
LW – low ballast factor
PSP – program start, parallel wiring
PRS – programmed rapid start ballast(std on T5)
Dimming:
DL - dimming, lutron
DA - dimming, advance
DO - dimming, osram
DU - dimming, utl
(Specify vendor ’s product catalog decription)
Voltage:
1 - 120v
7 - 480v
4 - 277v
8 - 347-480
5 - 347v
9- 120-277
Lenses/Louvers:
FA - pattern 12, acrylic .095”
FB - pattern 12, acrylic .125”
FC - pattern 19, acrylic .156”
FD - pattern 19, acrylic .187”
FE - pattern 15, acrylic .200”
PC - pattern 12, polycarb .125”
SP - ½” square molded silver parabolic
SL - 1½” square molded silver parabolic
Door Frames:
RS - flush white, steel
RE - flush white, aluminum
RH - regressed white, aluminum
RB - flush black, steel
RF - flush black, aluminum
RJ - regressed black, aluminum
BR - floating door (black reveal)
RA - heat removal, flush, white frame
Options
WG - 11ga wireguard in door
2G - 20 gauge crs housing and ends
ALUM - aluminum
EAI - enhanced aluminum insert
AAI - anodized aluminum insert
NYC - new york city
available with “ic” rating
Note: “ic” rated for use in insulated ceilings with 1, 2 or 3
32wT8 lamps.
Lamps:
L835 – 3500K
L841 – 4100K
Flex:
FX1 – 6’ metal flex, (3) 18ga leads, (2) straight connectors
FX2 – 6’ metal flex, (4) 18ga leads, (2) straight connectors
Emergency Ballasts:
EM1- 1-lamp (500-600 lumens)
EM1A -1-lamp (350-450 lumens)
EM2 - 2-lamps (1100-1400 lumens)
EM2A - 2-lamps (600-700 lumens)
EM3 - 1-lamp (600-700 lumens), 2 hours
SLL - spring-loaded latch (full doors only)
Flange Kits:
FK-22
FK-24
LUMAX INDUSTRIES, INC. Chestnut Avenue & Fourth Street
Altoona, PA 16603-0991 814-944-2537 Fax 814-944-6413
www.lumaxlighting.com
Accessories
RG
Series
PHOTOMETRIC DATA
Catalog Number: RG33224-CO1FARS
Lamps: Three F32T8-SP41Each Rated at 2900 Lumens
Total Luminaire Efficiency: 76.3%
Zonal Lumen Summary
Zone
Lumens %Lamp
%Fixt
0-30
2114
24.3
31.8
0-40
3456
39.7
52.0
0-60
5655
65.0
85.1
0-90
6642
76.3
100.0
90-180
0
0.0
0.0
0-180
6642
76.3
100.0
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Reflectance 20%
RC
80%
70%
50%
30%
10%
0%
RW 70% 50% 30% 10% 70% 50% 30% 10% 50% 30% 10% 50% 30% 10% 50% 30% 10% 0%
0 91 91 91 91 89 89 89 89 85 85 85 81 81 81 78 78 78 76
1
84
81
78
76
82
79
77
74
76
74
72
73
71
70
70
69
68
66
2
78
72
68
64
76
71
67
63
68
65
62
66
63
60
64
61
59
57
3
72
65
59
55
70
64
59
54
61
57
54
59
56
53
57
54
52
50
4
66
58
52
48
65
57
52
47
55
50
47
54
49
46
52
48
45
44
5
61
52
46
41
59
51
45
41
50
44
40
48
44
40
47
43
40
38
6
56
47
40
36
55
46
40
36
45
39
35
44
39
35
42
38
35
33
7
52
42
36
31
51
42
36
31
41
35
31
39
35
31
38
34
31
29
8
48
38
32
27
47
37
32
27
36
31
27
36
31
27
35
30
27
25
9
44
34
28
24
43
34
28
24
33
27
24
32
27
24
31
27
23
22
10
41
31
25
21
40
31
25
21
30
25
21
29
24
21
28
24
21
19
Plane:
Spacing Criteria:
Luminous Length:
0-Deg
1.2
21.500
90-Deg
1.3
45.500
Luminance in Candela Per Square Meter
Angle
Average Average Average
in Deg
0-Deg
45-Deg
90-Deg
0
4218
4218
4218
45
3524
3717
3836
55
2721
2859
3036
65
2021
1953
2103
75
1812
1555
2045
85
2181
2018
2581
DIMENSIONS
Specifications and dimensional data subject to
change without notice.
2 Lamp
3 Lamp
4 Lamp
LUMAX LIGHTING
RG2x22x4.0415
Download