WSA-XEE WSN-XEE 122÷402 NEW Water chiller WSA-XEE: cooling only WSN-XEE: heat pump Air cooled Indoor installation Capacity from 37 to 103 kW HYDRONIC ELFOEnergy Duct Medium The chillers and heat pumps of WSA-XEE and WSN-XEE series are indoor units with ducted condensation. Thanks to his special design ELFOEnergy Duct Medium main features are: Versatility: different combinations of inlet and outlet plug fans enable to connect easily the unit to the air ducts and to have high available head; High energy efficiency: ELFOEnergy Duct Medium besides being in Eurovent efficiency class A at full load grants high seasonal power efficiency thanks to the innovative cooling circuit optimized for partial load operation and the DST (Dynamic Supply Temperature) return control logic; Easy installation: the units are very compact and are supplied with high efficiency pumps on board; therefore the available space for other purposes is increased and the installations costs are reduced. Unit listed on www.eurovent-certification.com functions and features AIR Cooling only (WSA-XEE) Heat pump (WSN-XEE) R-410A Air cooled Indoor installation R-410A Hermetic Scroll dimensions and clearances (*) C A1 A A2 B1 B B2 CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. (*) Optional 94 Size – WSA-XEE A - Lenght B - Width C - Height A1 A2 B1 B2 S Operating weight mm mm mm mm mm mm mm kg Size – WSN-XEE A - Lenght B - Width C - Height A1 A2 B1 B2 mm mm mm mm mm mm mm 122 1450 780 1995 500 500 1000 1300 487 122 1450 780 1995 500 500 1000 1300 162 1450 780 1995 500 500 1000 1300 537 162 1875 780 1995 500 500 1000 1300 182 1875 780 1955 500 500 1000 1300 596 182 1875 780 1995 500 500 1000 1300 222 1875 780 1955 500 500 1000 1300 609 262 2650 780 1955 500 500 1000 1300 692 222 2650 780 1995 500 500 1000 1300 302 2650 780 1955 500 500 1000 1300 727 262 2650 780 1995 500 500 1000 1300 352 2650 780 1955 500 500 1000 1300 852 302 2650 780 1995 500 500 1000 1300 402 2650 780 1955 500 500 1000 1300 865 352 2650 780 1995 500 500 1000 1300 The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Data Sheet. S Standard (S) versions and configurations EO D B Vertical air exhaust (standard) Horizontal exhaust air Partial energy recovery Water low temperature HYDRONIC EV accessories CCCA1 Copper / aluminium condenser coil with Energy Guard DCC Aluminum Single pump at high discharge head 1PUB Single pump at loe discharge head ■• CSVX Couple of manual shut-off valves ■• IFWX Water steel mesh strainer MHP High and low pressure gauges ■• AMRX Rubber antivibration mounts ■• PGFCX Finned coil protection grill. PM Phase monitor SFSTR Disposal for inrush current reduction CMSC10 Serial communication module to LonWorks supervisor CMSC11 Serial communication module for BACnet-IP supervisor 1PUA CMSC12 CLSCLR CFSC SPC2 SPC1 SCP3 SCP4 PFCP SDV ■• KRIX FANQE Serial communication module for BACnet-MSTP supervisor Free contacts compressor state and local / remote management Free contacts for compressor state Set point compensation with outside temperature probe Set point compensation with 4-20 mA signal Set point compensation according to the outside enthalpy Compensation of set point with signal 0-10 V Power factor correction capacitors (cosfi > 0.9) Compressor discharge and suction shut-off valve Kit to remote the control interface by microprocessor Electrical panel ventilation Key to symbols: ■• Accessories supplied separately. technical data Size – WSA-XEE S Cooling capacity S Compressor power input S Total power input S EER (EN 14511:2011) S ESEER S Refrigerant circuits S No. of Compressors S Type of compressors S Standard air flow S Max external static pressure S Water flow rate (Utility Side) S Standard power supply Sound pressure level Size – WSN-XEE S Cooling capacity S Total power input S EER (EN 14511:2011) S ESEER S Heating capacity S Total power input S COP (EN 14511:2011) S Max external static pressure PR Cooling capacity PR Total power input PR ESEER PR Heating capacity PR Total power input PR COP (EN 14511:2011) Refrigerant circuits No. of Compressors Type of compressors Standard air flow Standard power supply (1) kW kW kW Nr Nr l/s Pa l/s V dB(A) kW kW kW kW Pa kW kW kW kW Nr Nr l/s V 122 36,8 11,6 12,5 2,95 4,42 1 2 Scroll 4444 630 1,8 400/3/50 64 122 33,2 12,9 2,58 3,9 41,3 12,7 3,25 100 33,2 12,9 3,9 42,2 10,3 4,09 1 2 Scroll 4444 400/3/50 162 42,4 13,7 14,5 2,92 4,58 1 2 Scroll 4444 570 2 400/3/50 65 162 38,2 15,1 2,53 3,85 47,9 14,7 3,26 100 38,2 15,1 3,85 49 11,9 4,12 1 2 Scroll 4444 400/3/50 Note (1) Data calculated in complance with Standard EN 14511:2011 Internal exchanger water = 12/7°C Air entering the external exchanger = 35°C S Standard (S) PR Unit for underfloor heating 182 50,1 16 17,1 2,93 4,61 1 2 Scroll 5000 450 2,4 400/3/50 66 182 43,4 18,7 2,32 3,46 55,9 17,7 3,16 100 43,4 18,7 3,46 57,1 14,4 3,96 1 2 Scroll 5000 400/3/50 222 59,2 19,8 21 2,82 4,52 1 2 Scroll 5000 450 2,8 400/3/50 67 262 68,5 23,2 24,1 2,84 4,5 1 2 Scroll 6667 630 3,3 400/3/50 66 222 52,1 22,1 2,36 3,54 65,1 20,5 3,18 100 52,1 22,1 3,54 66,5 16,9 3,94 1 2 Scroll 5000 400/3/50 302 79,4 26,1 27,6 2,88 4,42 1 2 Scroll 7500 450 3,8 400/3/50 68 262 61,9 24,6 2,51 3,74 77,3 23,5 3,29 100 61,9 24,6 3,74 79,4 19,6 4,05 1 2 Scroll 6667 400/3/50 352 90,6 30,2 31,7 2,86 4,55 1 2 Scroll 7500 420 4,3 400/3/50 69 302 71,4 28,3 2,52 3,78 88,3 27 3,27 100 71,4 28,3 3,78 90,3 22,4 4,03 1 2 Scroll 7500 400/3/50 402 103 35 37,4 2,75 4,49 1 2 Scroll 8333 240 4,9 400/3/50 71 352 79,2 33,7 2,35 3,5 97,9 30,6 3,2 100 79,2 33,7 3,5 100 25,2 3,96 1 2 Scroll 7500 400/3/50 WSN-XEE: PRELIMINARY DATA At the date of printing, the WSN-XEE data are not yet certified by Eurovent. 95