L-849 Voltage/Current, Style A and E LED Runway End Identifier Light (REIL) User Manual 96A0381 Retain for future use. Rev. L, 11/26/12 ETL Certified to FAA Specification AC 150/5345-51 latest version and LED Performance Requirements per FAA Engineering Brief 67 L-849 Voltage/Current, Style A and E 96A0381 Rev. L 11/26/12 Disclaimer Disclaimer Table of Contents This manual could contain technical inaccuracies or typographical errors. ADB Airfield Solutions reserves the right to revise this manual from time to time in the contents thereof without obligation of ADB Airfield Solutions to notify any person of such revision or change. Details and values given in this manual have been compiled with care. They are not binding, however, and ADB Airfield Solutions disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers. No warranty is made that the use of the information or of the products, processes or equipment to which this manual refers will not infringe any third party's patents or rights. Warranties Safety LED Products of ADB Airfield Solutions manufacture are guaranteed against mechanical, electrical, and physical defects for a period of four years after the date of installation and are guaranteed to be merchantable and fit for the ordinary purposes for which such products are made. ADB Airfield Solutions will correct by repair or replacement, at its option, equipment or parts which fail because of mechanical, electrical or physical defects, provided that the goods have been properly handled and stored prior to installation, properly installed and properly operated after installation, and provided further that Buyer gives ADB Airfield Solutions written notice of such defects after delivery of the goods to Buyer. Refer to the Safety section for more information on Material Handling Precautions and Storage precautions that must be followed. ADB Airfield Solutions reserves the right to examine goods upon which a claim is made. Said goods must be presented in the same condition as when the defect therein was discovered. ADB Airfield Solutions further reserves the right to require the return of such goods to establish any claim. ADB Airfield Solutions’ obligation under this guarantee is limited to making repair or replacement within a reasonable time after receipt of such written notice and does not include any other costs such as the cost of removal of defective part, installation of repaired product, labor or consequential damages of any kind, the exclusive remedy being to require such new parts to be furnished. ADB Airfield Solutions’ liability under no circumstances will exceed the contract price of goods claimed to be defective. Any returns under this guarantee are to be on a transportation charges prepaid basis. For products not manufactured by, but sold by ADB Airfield Solutions, warranty is limited to that extended by the original manufacturer. This is ADB Airfield Solutions’ sole guarantee and warranty with respect to the goods; there are no express warranties or warranties of fitness for any particular purpose or any implied warranties of fitness for any particular purpose or any implied warranties other than those made expressly herein. All such warranties being expressly disclaimed. Introduction Installation Trademarks General notice: other product names used here are for identification purposes only and may be trademarks of their respective companies. Proprietary Information Operation Parts This information carrier contains proprietary information, which shall not be used for other purposes than those for which it has been released, nor be reproduced or disclosed to third parties without the prior written consent of ADB Airfield Solutions. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopy, recording, or otherwise, without the prior written permission of ADB Airfield Solutions. No patent liability is assumed with respect to the use of the information contained herein. Neither is any liability assumed for damages resulting from the use of the information contained herein. ADB Airfield Solutions shall not be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product. ADB Airfield Solutions shall not be liable against any damages arising from the use of any options or parts other than those designated as approved products. Copyright © 2012 by ADB Airfield Solutions. All rights reserved. Schematics ii © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E Record of Change Updated setting the operational modes 2881 JR RS 10/18/10 J K L Updated Drawings and start up procedures updated parts and 177A0044 drawings Update drawings / parts and schematics 2253 JC JC JC JG JG BE 05/17/11 D E F G Checked WT WT/JR Approved WT WT Date 9/18/07 12/13/07 1900 JC JC 2/29/08 1903 JC JC 3/11/08 1987 JC JC 6/20/08 2061 ER DR 9/17/08 2130 DR RW 12/11/08 2355 ER GM 09/09/09 Table of Contents I C EC No. N/A 1858 Safety H Description Released manual for certification Released manual for production Corrected external wiring diagram descriptions Added description to PC Assembly 44A6724 Added Stainless Steel enclosure (no paint) to ordering code General editorial updates Drawing updates - added 2 leg current to parts Update install diagram to match FAA Installation Introduction Record of Change Rev A B 12/06/12 Schematics Parts Operation Page All All “Schematics ” on page 31 “Parts” on page 25 “Parts” on page 25 All Section 5, 6, and 7 Install Diag 3-8 4-1 > 4-2 7-1 > 7-5 Parts All Record of Change a.1 Record of Change © 2012 ADB Airfield Solutions All Rights Reserved iii L-849 Voltage/Current, Style A and E Record of Change 96A0381 Rev. L 11/26/12 Disclaimer Table of Contents Safety Introduction Installation Record of Change Operation Parts Schematics iv © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E TOC Disclaimer TABLE OF CONTENTS L-849 Voltage/Current, Style A and E ................................................................................................................. i a.1 :Record of Change ................................................................................................iii Table of Contents 1.0: Safety ................................................................................................................... 1 Safety 1.1 :To use this equipment safely: .............................................................................. 1 1.1.1 :Additional Reference Materials: .................................................................. 1 1.1.2 :Qualified Personnel ..................................................................................... 1 1.1.3 :Intended Use ............................................................................................... 1 1.1.4 :Storage ........................................................................................................ 1 1.1.4.1 :Operation ............................................................................................ 2 1.1.4.2 :Material Handling Precautions ............................................................ 2 1.1.4.3 :Action in the Event of a System or Component Malfunction............... 2 1.1.4.4 :Maintenance and Repair..................................................................... 2 1.1.4.5 :Operation of Overloaded Regulators .................................................. 2 Installation Introduction TOC 2.0: Introduction ......................................................................................................... 3 2.1 :Specifications ....................................................................................................... 4 2.2 :Theory of Operation ............................................................................................. 4 2.2.1 :General ........................................................................................................ 4 2.2.1.1 :Theory of Operation: Overview ........................................................... 4 3.0: Installation ........................................................................................................... 5 Schematics Parts Operation 3.1 :L-849A/E REIL: Required Equipment .................................................................. 5 3.1.1 :Unpacking .................................................................................................... 6 3.1.2 :Specific Site Information .............................................................................. 6 3.1.3 :Tools and Test Equipment ........................................................................... 7 3.1.4 :Installation of the Control Cabinets .............................................................. 7 3.1.5 :Mounting Options ........................................................................................ 7 3.1.6 :Mounting Cabinets ....................................................................................... 8 3.1.6.1 :Mounting the Cabinets ........................................................................ 8 3.1.6.2 :Series Circuit Connection Installation ............................................... 10 3.1.6.3 :For L-849V voltage powered REILS with current sensing ................ 10 3.1.7 :Aiming the Flash Heads ............................................................................ 10 3.1.7.1 :Horizontal Aiming Adjustments ......................................................... 10 3.1.7.2 :Vertical Aiming Adjustment ............................................................... 10 3.1.8 :Electrical Connections ............................................................................... 11 3.1.8.1 :Grounding the Units .......................................................................... 11 3.1.8.2 :Cabinet and Remote Control Wiring ................................................. 11 3.1.9 :240Vac Powered REIL .............................................................................. 12 3.1.10 :Installation Checkout ............................................................................... 12 3.1.10.1 :Wiring Checkout ............................................................................. 12 3.1.10.2 :Connector, Plug, and Jack Checkout ............................................. 13 3.1.11 :Safety Switch Checkout ........................................................................... 13 3.1.12 :Initial Startup and Preliminary Test .......................................................... 13 3.1.12.1 :Startup Procedures ......................................................................... 14 4.0: Operation ........................................................................................................... 17 4.1 :Operational Modes ............................................................................................. 17 4.2 :Operating Procedures ........................................................................................ 18 4.2.1 :REIL Startup Procedure ............................................................................ 18 4.2.2 :Changing Step Modes (Primary only) ........................................................ 18 4.2.3 :Shutdown Procedure ................................................................................. 18 5.0: Maintenance and Repair................................................................................... 19 5.1 :Maintenance Schedule ....................................................................................... 19 5.1.1 :Replacing LED PCB Assembly .................................................................. 19 © 2012 ADB Airfield Solutions All Rights Reserved iii L-849 Voltage/Current, Style A and E TOC 96A0381 Rev. L 11/26/12 Disclaimer 5.1.2 :Troubleshooting .........................................................................................20 6.0: Parts ...................................................................................................................25 Table of Contents 6.1 :849A/E REIL Ordering Code Numbering System ...............................................25 6.1.1 :Control Panel Assembly Part Numbers .....................................................26 6.1.2 :Optical Assembly Part Numbers ................................................................27 6.1.3 :L-849V/I, Style A/E Assembly Part Number ..............................................28 6.2 :Numerical Parts Lists ..........................................................................................29 7.0: Schematics ........................................................................................................31 Document Date (12/2010) 38 Safety Introduction Installation TOC Operation Parts Schematics iv © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 This section contains general safety instructions for installing and using ADB Airfield Solutions equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate. 1.1 To use this equipment safely: Disclaimer 1.0 Safety L-849 Voltage/Current, Style A and E Safety WARNING • • • • • 1.1.2 Qualified Personnel The term qualified personnel is defined here as individuals who thoroughly understand the equipment and its safe operation, maintenance and repair. Qualified personnel are physically capable of performing the required tasks, familiar with all relevant safety rules and regulations and have been trained to safely install, operate, maintain and repair the equipment. It is the responsibility of the company operating this equipment to ensure that its personnel meet these requirements. Always use required personal protective equipment (PPE) and follow safe electrical work practices. Safety Installation Introduction Safety 1.1.1 Additional Reference Materials: Table of Contents Read installation instructions in their entirety before starting installation. • Refer to the FAA Advisory Circular AC 150/5340-26, Maintenance of Airport Visual Aids Facilities, for instructions on safety precautions. • Observe all safety regulations. To avoid injuries, always disconnect power before making any wiring connections or touching any parts. Refer to FAA Advisory Circular AC 150/5340-26. • Become familiar with the general safety instructions in this section of the manual before installing, operating, maintaining or repairing this equipment. • Read and carefully follow the instructions throughout this manual for performing specific tasks and working with specific equipment. • Make this manual available to personnel installing, operating, maintaining or repairing this equipment. • Follow all applicable safety procedures required by your company, industry standards and government or other regulatory agencies. • Install all electrical connections to local code. • Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All wiring must meet local codes. • Route electrical wiring along a protected path. Make sure they will not be damaged by moving equipment. • Protect components from damage, wear, and harsh environment conditions. • Allow ample room for maintenance, panel accessibility, and cover removal. • Protect components from damage, wear, and harsh environment conditions. • Allow ample room for maintenance, panel accessibility, and cover removal. • Protect equipment with safety devices as specified by applicable safety regulations. • If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper functioning prior to returning power to the circuit. Operation NFPA 70B, Electrical Equipment Maintenance. NFPA 70E, Electrical Safety Requirements for Employee Workplaces. ANSI/NFPA 79, Electrical Standards for Metalworking Machine Tools. OSHA 29 CFR, Part 1910, Occupational Health and Safety Standards. National and local electrical codes and standards. Parts 1.1.3 Intended Use WARNING Using this equipment in ways other than described in this manual may result in personal injury, death or property and equipment damage. Use this equipment only as described in this manual. Schematics ADB Airfield Solutions cannot be responsible for injuries or damages resulting from nonstandard, unintended applications of its equipment. This equipment is designed and intended only for the purpose described in this manual. Uses not described in this manual are considered unintended uses and may result in serious personal injury, death or property and equipment damage. Unintended uses may result from taking the following actions: • Making changes to equipment that are not recommended or described in this manual or using parts that are not genuine ADB Airfield Solutions replacement parts. • Failing to make sure that auxiliary equipment complies with approval-agency requirements, local codes and all applicable safety standards. • Using materials or auxiliary equipment that are inappropriate or incompatible with ADB Airfield Solutions equipment. • Allowing unqualified personnel to perform any task. 1.1.4 Storage CAUTION If equipment is to be stored prior to installation, it must be protected from the weather and kept free of condensation and dust. Failure to follow this instruction can result in injury or equipment damage. © 2012 ADB Airfield Solutions All Rights Reserved 1 L-849 Voltage/Current, Style A and E To use this equipment safely: 96A0381 Rev. L 11/26/12 Disclaimer 1.1.4.1 Operation WARNING Table of Contents • Only qualified personnel, physically capable of operating the equipment and with no impairments in their judgment or reaction times, should operate this equipment. • Read all system component manuals before operating this equipment. A thorough understanding of system components and their operation will help you operate the system safely and efficiently. • Before starting this equipment, check all safety interlocks, fire-detection systems, and protective devices such as panels and covers. Make sure all devices are fully functional. Do not operate the system if these devices are not working properly. Do not deactivate or bypass automatic safety interlocks or locked-out electrical disconnects or pneumatic valves. • Protect equipment with safety devices as specified by applicable safety regulations. • If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper functioning. • Route electrical wiring along a protected path. Make sure they will not be damaged by moving equipment. • Never operate equipment with a known malfunction. • Do not attempt to operate or service electrical equipment if standing water is present. • Use this equipment only in the environments for which it is rated. Do not operate this equipment in humid, flammable, or explosive environments unless it has been rated for safe operation in these environments. • Never touch exposed electrical connections on equipment while the power is ON. Safety Introduction Installation To use this equipment safely: 1.1.4.2 Material Handling Precautions CAUTION This equipment may contain electrostatic sensitive devices. • Protect from electrostatic discharge. • Electronic modules and components should be touched only when this is unavoidable e.g. soldering, replacement. • Before touching any component of the cabinet you should bring your body to the same potential as the cabinet by touching a conductive earthed part of the cabinet. • Electronic modules or components must not be brought in contact with highly insulating materials such as plastic sheets, synthetic fiber clothing. They must be laid down on conductive surfaces. • The tip of the soldering iron must be grounded. • Electronic modules and components must be stored and transported in conductive packing. Operation 1.1.4.3 Action in the Event of a System or Component Malfunction WARNING • Do not operate a system that contains malfunctioning components. If a component malfunctions, turn the system OFF immediately. • Disconnect and lock out electrical power. • Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component according to instructions provided in its manual. Parts 1.1.4.4 Maintenance and Repair WARNING Schematics Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks. • Only persons who are properly trained and familiar with ADB Airfield Solutions equipment are permitted to service this equipment. • Disconnect and lock out electrical power. • Always use safety devices when working on this equipment. • Follow the recommended maintenance procedures in the product manuals. • Do not service or adjust any equipment unless another person trained in first aid and CPR is present. • Connect all disconnected equipment ground cables and wires after servicing equipment. Ground all conductive equipment. • Use only approved ADB Airfield Solutions replacement parts. Using unapproved parts or making unapproved modifications to equipment may void agency approvals and create safety hazards. • Check interlock systems periodically to ensure their effectiveness. • Do not attempt to service electrical equipment if standing water is present. Use caution when servicing electrical equipment in a high-humidity environment. • Use tools with insulated handles when working with electrical equipment. 1.1.4.5 Operation of Overloaded Regulators WARNING • Operation of a Regulator while overloaded at any step may result in equipment failure or equipment damage. 2 © 2012 ADB Airfield Solutions All Rights Reserved 2.0 Introduction WARNING Read the instructions in their entirety before starting installation. This section provides an introduction to the ADB FAA Type L-849V (voltage) and I (current), Style A and E, REIL with LED optical flash heads See Figure 1. The ADB FAA Type L-849V (voltage) and I (current), Style A and E, REIL with LED optical flash heads consists of two unidirectional light units, one located on each side of the runway. Each REIL assembly utilizes an integrated head and power supply. The Primary REIL assembly controls operation of the Secondary REIL assembly. Remote control signals are connected only to the Primary assembly. These light units flash twice a second to provide a visual indication to pilots of the runway threshold during an approach for landing. Safety REIL ASSEMBLY Operation Installation Introduction Figure 1: Disclaimer L-849 Voltage/Current, Style A and E Introduction Table of Contents 96A0381 Rev. L 11/26/12 Parts NOTE: The L-867 baseplate that the assembly is mounted on is not a part of the REIL assembly. Refer to Table 1 for the L-849 optical assembly type and style. Optical Assembly FAA Type/Style Power L849I/A 2.8A-6.6A Unidirectional, 1 Brightness Step (high intensity) L849I/E 2.8A-6.6A Unidirectional, 3 Brightness Steps (low, medium, high intensity) L-849V/A 240 Vac (2 wire) or 120/240Vac (3 wire) ±10% 50/60Hz Unidirectional, 1 Brightness Step (high intensity) L-849V/ E 240 Vac (2 wire) or 120/240Vac (3 wire) ±10% 50/60Hz Unidirectional, 3 Brightness Steps (low, medium, high intensity) © 2012 ADB Airfield Solutions All Rights Reserved Schematics Table 1: Optical Assembly 3 L-849 Voltage/Current, Style A and E Specifications Disclaimer 2.1 Specifications 96A0381 Rev. L 11/26/12 Table 2: L-849 V/I, Style A/E Assembly Power Rating L-849V 120/240Vac, ±10%, 60Hz, 3-wire L-849V 240Vac, ±10%, 50/60Hz, 2-wire L-849I 2.8 - 6.6 A from a Constant Current Regulator LED Clusters Table of Contents LED Average Life L-849V/I, A Safety Photometric Output1 L-849V/I, E 50,000 hours Intensity 15,000 cd High Intensity Candelas 15,000 cd Medium Intensity Candelas 1,500 cd Low Intensity Candelas 300 cd Introduction Installation Operation Flash Rate 120 flashes per minute with less than 1% misfiring (no consecutive skips) over average life. Operating Temperature Range -40 to +55 °C (-40 to +131 °F) Wind Velocities up to 150 knots (173 mph) (278 km/h) Relative Humidity 0 to 100% Altitude Sea level to 10,000 ft (3000 m) Dimensions 20 x 16 x 8 inches (508 x 406 x 203.2 mm) (enclosure L x H x D) Weight 46 lbs (each unit) 1 Photometric output is within a beam pattern of 10 degrees vertical by 30 degrees horizontal for each flasher (tolerance of 50% in effective intensity). The effective intensities are maintained when operated within the operating temperature range listed. 2.2 Theory of Operation Parts 2.2.1 General The L-849 REIL with LED cluster flashing light system provides a visual indication of the runway threshold to pilots during an approach for landing. The system is composed of two flashers that operate simultaneously to produce short-duration flashes twice a second. Schematics The REIL system may be operated either by local or remote control. The L-849A operates at high intensity and the L849E operates at low, medium, or high intensity. 2.2.1.1 Theory of Operation: Overview 4 The L-849 LED systems consist of an individual control cabinet with an integrated flash head. The electronic package housed in the control cabinet is the same for both flash heads. © 2012 ADB Airfield Solutions All Rights Reserved 3.0 Installation L-849 Voltage/Current, Style A and E Installation This section provides instructions for installing the L-849 Runway End Identifier Lights (REIL). Refer to the airport project plans and specifications for the specific installation instructions. Also see FAA AC 150/5340-30. WARNING Read the instructions in their entirety before starting installation. Table of Contents • Refer to the FAA Advisory Circular AC 150/5340-26, Maintenance of Airport Visual Aids Facilities, for instructions on safety precautions. • Observe all safety regulations. To avoid injuries, always disconnect power before making any wiring connections or touching any parts. Refer to FAA Advisory Circular AC 150/5340-26. Safety • Become familiar with the general safety instructions in this section of the manual before installing, operating, maintaining or repairing this equipment. • Read and carefully follow the instructions throughout this manual for performing specific tasks and working with specific equipment. Installation Introduction Installation • Make this manual available to personnel installing, operating, maintaining or repairing this equipment. • Follow all applicable safety procedures required by your company, industry standards and government or other regulatory agencies. • Route electrical wiring along a protected path. Make sure they will not be damaged by moving equipment. • Protect components from damage, wear, and harsh environment conditions. • Allow ample room for maintenance, panel accessibility, and cover removal. • Protect equipment with safety devices as specified by applicable safety regulations. Operation • If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper functioning prior to returning power to the circuit. Refer to Table 3 for required equipment that is supplied. Refer to Table 4 for required equipment that is not supplied. Refer to the Parts section for ordering information. Required Equipment Supplied Description REIL system 1 Instruction manual Table 4: Quantity 1 per order Required Equipment Not Supplied Description Wire, input power. (AWG 16, 600V min. assuming distance is 600 feet or less). See Table 5 if distance >600 feet. Quantity As required Wire, remote control (AWG 16, minimum, 600 V) As required Wire, interconnection individual control cabinets (AWG 16, minimum, 600 V) As required Remote control device As required Ground rods and AWG 6 solid copper ground wire As required External circuit breaker for voltage powered REIL 1 Base pads, cement for mounting cabinets As required Silicone grease for pipe thread installation As required Conduit elbow, 2-in. (50.8 mm-) diameter 2 Conduit elbow coupling to attach frangible coupling to elbow 2 Base flange, 6 ¼-in. (158.75-mm-) diameter. Not required if conduit elbow coupling is used. 62B0107 2 L-867 base, 16-in. (406.4-mm-) diameter. 1 © 2012 ADB Airfield Solutions All Rights Reserved Parts Table 3: Schematics 3.1 L-849A/E REIL: Required Equipment Disclaimer 96A0381 Rev. L 11/26/12 5 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment 96A0381 Rev. L 11/26/12 Disclaimer Description Quantity L-823 connector, male and female, kit 1 L-823 male secondary splice kit As required Level 1 Padlock for control cabinets (if required) 2 Table of Contents Table 5: External Power AWG Wire Size Distance between Individual Control Cabinet Safety 3.1.1 Unpacking AWG Wire Size L-849V/I, A/E Feet L-849V/I, A/E Meters Minimum 1400 427 12 900 275 14 600 183 16 Introduction Installation L-849A/E REIL: Required Equipment The equipment is shipped ready for installation. Handle equipment very carefully to prevent component damage. Unpack the carton upon receipt and check the contents and their condition. Note any exterior damage to the carton that might lead to detection of equipment damage. If you note any damage to any equipment, file a claim with the carrier immediately. The carrier may need to inspect the equipment. 3.1.2 Specific Site Information Site information is provided in the airport project plans and specifications. The installation must conform to the applicable sections of the National Electric Code and local codes. Refer to the guidelines below when preparing the site. Operation Parts • See Figure 2. Each L-849 REIL light unit should be placed in a line with the runway threshold at 40 feet (12.2 m) from the runway edge. A tolerance of 100 feet (30.4 m) upwind and 30 Feet (9.1 m) downwind with respect to being in line with the threshold is permitted. • The light units shall be equally spaced with respect to each other from the runway threshold. See FAA Advisory Circular AC 150/5340-30 for additional installation requirements. • The beam centerline of each light unit is aimed 15 degrees outward from a line parallel to the runway centerline and inclined at an angle of 10 degrees above the horizontal. • If REILs are used with VASI-2, install REILs 75 feet from the runway edge. Schematics 6 © 2012 ADB Airfield Solutions All Rights Reserved L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment BEAM AXIS Conventional tools and test equipment used by general and electrical contractors should suffice for installation. However, a true RMS multi-meter such as a Fluke 87V (or equivalent) and a clamp-on amp probe should be available. A waterproof shroud is needed if a cabinet door has to be opened in extremely inclement weather. 3.1.4 Installation of the Control Cabinets Unpack the individual cabinets, and open the cabinet doors by depressing the "red" button at the bottom of the door lever and then insert a medium width bladed screw driver in the slot and rotate the screwdriver counter clockwise and turn the handle, approximately ¼ turn clockwise to unlock and open the door. NOTE: The ADB LED L-849V/I, A and E REIL uses the same enclosure for both the Primary and Secondary Units. Make sure all components in the enclosures are in place and fastened to the panel assembly. The ON/OFF service switch in the cabinets should be in the OFF position. If all components are in place, close the door and tighten the bolts. 3.1.5 Mounting Options The standard mounting method is with a single leg. See Figure 3 and Figure 4 for mounting instructions. An optional two leg mounting system is available- see Figure 23. © 2012 ADB Airfield Solutions All Rights Reserved 7 Operation 3.1.3 Tools and Test Equipment Parts BEAM AXIS 15° Installation Introduction L-849A/E REIL: Required Equipment Safety TYPICAL REIL LAYOUT Table of Contents 15° REIL THRESHOLD LIGHTS REIL 40 FEET+35'/-0' RUNWAY THRESHOLD RUNWAY CENTERLINE Disclaimer Typical Layout for REIL 40 FEET +35' / -0' Figure 2: Schematics 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment 96A0381 Rev. L 11/26/12 Disclaimer Figure 3: L-849V/I REIL Standard Single Leg Mounting Configuration Table of Contents Safety 3.1.6 Mounting Cabinets NOTE: Mount the LED L-849 REIL cabinet directly onto the existing frangible coupling supplied with the assembly. Introduction Installation L-849A/E REIL: Required Equipment Figure 4 is given only as guide. Check local codes and the airport project plans and specifications for installation requirements. See FAA AC 150/5345-30 for additional mounting instructions. Not shown is the L-867 base can to house the L-830 or L-831 isolation transformer for current driven applications. Figure 4: Single-Leg Control Cabinet 3 Operation 4 Parts 2 Schematics 5 1. L-849 Assembly (not shown) 3.1.6.1 Mounting the Cabinets 4. Use Two-Inch Threaded Coupling if Flange Not Used. 2. Two-Inch Elbow for External Wires 5. 3. Frangible Coupling (supplied) 6. Concrete Foundation To install the L-849 REIL control cabinets, perform the following procedure: NOTE: A customer-supplied external circuit breaker should be separately mounted to the input power supply lines. 1. Install a customer-supplied 2-inch (50.8 mm) conduit elbow in the concrete pad for external wiring routing into the bottom mounting hub of the cabinet. NOTE: Depth of the concrete foundation should be a minimum of 6 in. (152.4 mm) below frost line. 8 © 2012 ADB Airfield Solutions All Rights Reserved 2. Install a customer-supplied 2-inch (50.8 mm) threaded coupling on the threaded end of the conduit elbow. NOTE: Make sure the coupling is installed level and square with the concrete pad. Level by adjusting slip-fitters on pipe extending downward from cabinet. An alternate method is to use a 6 1/4-inch (158.75 mm) base flange, and bolt the flange to the concrete pad over the conduit elbow flush with top of pad. When the base flange is used, make sure the flange can be installed level with the concrete pad. Use shims on the flange if further leveling of unit is required. Make sure the conduit is flush with the top of the concrete pad. Disclaimer L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment Table of Contents 96A0381 Rev. L 11/26/12 3. Coat the threaded end of frangible coupling with silicone grease and thread onto base flange or conduit elbow coupling. 5. Place a level on top of the cabinet. Level by adjusting slip-fitters on the pipe extending downward from the cabinet. 6. Tighten the hex head screws in the mounting hub against the frangible coupling when the cabinet is level. NOTE: To properly aim the light unit, each cabinet must be level and parallel to the runway centerline when the cabinets are installed. Schematics Parts Operation 7. Tighten the hex head screws against the hub. Installation Introduction L-849A/E REIL: Required Equipment Safety 4. Loosen the hex head screws in the mounting hub and mount cabinet on frangible coupling. © 2012 ADB Airfield Solutions All Rights Reserved 9 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment 96A0381 Rev. L 11/26/12 Disclaimer 3.1.6.2 Series Circuit Connection Installation • For L-849I series circuit powered REILS, install a L-867 base can to house the L-830 or L831 isolation transformer. See Figure 23 for details. 3.1.6.3 For L-849V voltage powered REILS with current sensing • For L-849V voltage powered REILS that use current sensing for remote control, install a L-867 base can next to the Primary enclosure. See Figure 23 for details. Table of Contents 3.1.7 Aiming the Flash Heads 3.1.7.1 Horizontal Aiming Adjustments The horizontal axis of the light beam can be adjusted at a maximum angle of 15 degrees from runway center line. To adjust the horizontal setting, perform the following procedure: Figure 5: Horizontal Aiming Safety Horizontal Aiming Scale and Hex Introduction Installation L-849A/E REIL: Required Equipment 1. See Figure 5. Locate and loosen the hex head cap screws on horizontal aiming bracket found on both outside ends of the enclosure. Manually rotate the head assembly and orientate the beam axis of the flash head to the desired angle to a maximum of 15 degrees outward from a line parallel to the runway centerline. Ref. Figure 2. Operation 2. Hand-tighten the hex screws and then check the new setting by verifying that the alignment pointer is set at the required horizontal angle. Loosen the hex head screw and repeat the adjustment procedure if the angle is not correct. 3. If horizontal setting is correct, ensure that the screws are tight to lock the head at the desired angle. Parts 3.1.7.2 Vertical Aiming Adjustment The vertical axis of the light beam can be adjusted upward at a maximum angle of 15 degrees above the horizontal. To adjust the vertical setting, perform the following procedure: Figure 6: Vertical Aiming Vertical Aiming Adjustment Scale Schematics Vertical Aiming Adjustment Knob 1. See Figure 6. Open the enclosure door and find the vertical aiming scale located in the upper left - hand corner inside the enclosure. Next locate the adjustment screw knob 10 © 2012 ADB Airfield Solutions All Rights Reserved Disconnect power to the lighting circuit before attempting to make any electrical connections. Coordinate a power outage with air traffic personnel before turning power to the airport lighting system off. See Figure 19 thru Figure 22 in the “Schematics” on page 31 for external wire connections to the flash units. NOTE: All electrical wiring shall be made in accordance with the National Electrical Code and the local regulator authority. Wiring between the flash head and the individual control cabinet is connected and supplied with unit. Proper wire size information for the external connections is given in Figure 19 thru Figure 22. NOTE: It is recommended that external lightning arrestors be added to incoming power lines as local conditions require. 3.1.8.1 Grounding the Units WARNING Read installation instructions in their entirety before starting installation. Pipe straps shall not be used for grounding purposes. Ground connections and lugs shall be the best commercial type. Ground the Primary and Secondary units by connecting a No. 6 bare solid copper wire at the earth ground lug provided inside the cabinets and route the wire through the conduit to the grounding rod. The ground resistance shall not exceed 25 ohms with the power feeder neutral disconnected. If necessary, additional ground rods shall be installed and interconnected to obtain the required resistance. The ground wires shall be connected to the ground rods by either an exothermic process (Erico Products Corporation, Cadweld, Burndy Corporation, Thermoweld or equivalent) or by brazing. 3.1.8.2 Cabinet and Remote Control Wiring Refer to the guidelines below when wiring the cabinet and the remote control. For L-849 REILs, install interconnecting power and control wiring (AWG 16 minimum, 600 V) between terminal block TB1 in each cabinet. See Figure 19 and Figure 22. • Make remote control circuitry connections (AWG 16 minimum, 600 V) to Primary terminal block TB1 in both cabinets. See Figure 19 for L-849I series circuit powered applications. See Figure Figure 22 for L-849V voltage powered applications. NOTE: When the current sensing option is used on L-849V REILS, remote control is not possible and TB1 terminals 4 through 8 are not used. • • Check for proper installation and firm connections. • For L-849V voltage powered REILS, connect 120/240Vac (3 wire) or 240Vac (2 wire) to TB1 as shown in Figure 19. Connect an isolation transformer to the Primary unit if optional current sensing is used. For L-849I series circuit powered REILS, connect a 200W isolation transformer as shown in Figure 22. © 2012 ADB Airfield Solutions All Rights Reserved 11 Table of Contents WARNING Read the instructions in their entirety before starting installation. Safety 3.1.8 Electrical Connections Installation Introduction L-849A/E REIL: Required Equipment 3. When desired vertical angle is obtained, tighten the jam nut. Once the jam nut is tight, verify angle by checking the scale. Check the alignment pointer on the scale to verify that the required vertical angle is correct. Repeat the adjustment procedure if the angle is not correct. Operation 2. Rotate the vertical adjustment screw knob CW to increase the angle and turn CCW to decrease the angle. Verify the angle by viewing the vertical adjustment scale. Parts located inside in the upper center of the enclosure. Loosen the jam nut located behind the knob. Disclaimer L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment Schematics 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment 96A0381 Rev. L 11/26/12 Disclaimer Table 6: L-849A/E, V/I, TB1 Terminal Functions - Control Cabinet 1 & 2 Terminal Function Note TB1-1 Failure Indication Relay N.O. Contact TB1-2 Failure Indication Relay Common Contact TB1-3 Failure Indication Relay N.C. Contact Table of Contents TB1-4 Remote Control – Identification ON TB1-5 Remote Control – Low A TB1-6 Remote Control – Medium A TB1-7 Remote Control – High A Safety Introduction Installation L-849A/E REIL: Required Equipment TB1-8 Remote Control – 120Vdc Source TB1-9 Remote control – 120Vdc Return TB1-10 Trigger Input TB1-11 Trigger Output TB1-12 Spare TB1-13 Spare TB1-14 VAC Input TB1-15 VAC Input TB1-16 Neutral TB1-17 Earth TB1-18 Current Monitoring Option B TB1-19 Current Monitoring Option B NOTE A: L-849V/I, E Only Operation NOTE B: Used if optional current sensing is present 3.1.9 240Vac Powered REIL Perform the procedure below if power for the REIL system is provided from a 120/240Vac split or 240Vac single phase power supply. To install 120/240Vac or 240Vac powered REIL, perform the following procedure: Parts 1. Install interconnecting and control wiring as specified in Control Cabinet and Remote Control Wiring in this section. 2. Connect the 120/240Vac or 240Vac power supply lines to a customer-supplied external circuit breaker, if required. Schematics 3. Disengage the circuit breaker and connect power supply lines from the circuit breaker to terminal block TB1 terminals labeled VAC IN-1 and VAC IN-2 in the cabinet. 4. Tighten all connections. 3.1.10 Installation Checkout This subsection describes procedures for installation checkout. See Figures in the Wiring Schematics section. 3.1.10.1 Wiring Checkout Refer to the guidelines below when checking out wiring. • All grounding connections to equipment, housing, structures, and ground rods shall be thoroughly checked. The ground resistance of all ground rods shall be within the limits specified in project plans and specifications. WARNING All power should be off while resistance checks are being made. A potential of 240 Vac may be present, which can be lethal. 12 © 2012 ADB Airfield Solutions All Rights Reserved All power and control wiring shall be carefully and thoroughly verified. Using an ohmmeter, check all wires to make sure that proper connections are made. 3.1.10.2 Connector, Plug, and Jack Checkout CAUTION If the system is turned on and wiring is connected improperly, all or part of the system can be damaged and void the warranty. Carefully check all connections plug and jack connections, and other wiring disconnects for proper mating. Check all terminal board connections for tightness. 3.1.11 Safety Switch Checkout Check the Primary and Secondary cabinets and flash heads for complete closure and latching, making sure that the interlock safety switches are depressed. 3.1.12 Initial Startup and Preliminary Test WARNING Before applying power to any part of the system, carefully read and observe at all times the safety instructions in the Safety section in this manual. Table of Contents • Disclaimer L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment Safety 96A0381 Rev. L 11/26/12 In each LED L-849 REIL control cabinet insure that the control switches are set to OFF. Turn on power to the REIL (engage external circuit breaker for voltage powered applications or turn on CCR for series circuit powered applications) and verify that the following is present on TB1 in the control cabinet: • L-849I: Place a clamp-on ammeter probe around TB1-14. Insure 2.8 to 6.6A (for 5-step CCRs) or 4.8A-6.6A (for 3-step CCRs) is present and matches the CCR step setting. • L-849V: For 120/240Vac powered REILS, verify the following voltages are present in each cabinet: — TBI-14 to TBI-16: 120Vac — TBI-15 to TBI-16: 120Vac Installation Introduction L-849A/E REIL: Required Equipment Refer to the guidelines below upon initial startup and preliminary testing. — For 240VAC powered REILS, verify the following voltage is present in each cabinet: TBI-14 to TBI-15: 240Vac • If the optional external failure indicator is used, set the Misfire Threshold switch SW1 on the Flasher Control Board to the desired consecutive misfire alarm level. SW1 may be set from 1 to 7. Set SW1 to zero if the external failure indicator is not used. Operation — TBI-14 to TBI-15: 240Vac Parts NOTE: Changing Step Modes (Primary only) Only the Primary Unit requires programming. — Press the CURRENT ADJUST button SET HIGH for 4 seconds. The HIGH LED will blink for 2 seconds and turn off. Changing from a 1-step setting to a 3-step setting: — Press the CURRENT ADJUST button SET LOW, SET MED and SET HIGH buttons simultaneously for 4 seconds. The LOW, MED, and HIGH LEDs will blink for 2 seconds and then turn off. © 2012 ADB Airfield Solutions All Rights Reserved 13 Schematics Changing from a 3-step setting to a single-step setting: L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment Disclaimer 3.1.12.1 Startup Procedures 96A0381 Rev. L 11/26/12 • Turn the Primary unit ON, followed by the Secondary unit. Check the L-849 REIL system in all modes of operation. Refer to REIL Startup Procedure in the Operation section. Check the remote control operations, if used. For current sensing, set the activation levels as follows: • • L-849 A (One-Step) (see Figure 11) Changing from a 3-step setting to a single-step setting: Table of Contents — Press the CURRENT ADJUST button SET HIGH for 4 seconds. The HIGH LED will blink for 2 seconds and turn off. — Set the constant current regulator (CCR) to the step setting where REIL operation is desired. Safety — On the LED REIL control board, 44A6724, in the Primary Unit, turn the rotary switch to the ‘Remote’ position. Push the SET HIGH push button for 4 seconds. The LED D20 will light for 2 seconds and turn off. Release the button. — The board is now programmed for the desired current to activate the unit. — The REIL will shut off at lower current steps. Introduction Installation L-849A/E REIL: Required Equipment NOTE: Only the primary unit is programmed. The secondary unit must not be programmed. • • L-849 E (Three-Step) (see Figure 11) Changing from a 1-step setting to a 3-step setting: — Press the CURRENT ADJUST button SET LOW, SET MED and SET HIGH buttons simultaneously for 4 seconds. The LOW, MED, and HIGH LEDs will blink for 2 seconds and then turn off. — Set the constant current regulator (CCR) to the highest step setting where Low intensity REIL operation is desired. — On the LED REIL control board, 44A6724, in the Primary Unit, turn the rotary switch to the ‘Remote’ position. Press and hold the SET LOW Switch SW2 for 4 seconds. The ‘Low’ LED D18 will flash. Operation — Set the CCR to the highest step setting where Medium intensity REIL operation is desired. Press and hold the SET MEDIUM Switch SW3 on the Flasher Control Board for 4 seconds. The ‘Med’ LED D19 will flash. Parts — Set the CCR to the LOW intensity setting, verify that the LOW LED D18 is lit. — Set the CCR to the highest step setting where High intensity REIL operation is desired. Press and hold the SET HIGH Switch SW4 on the Flasher Control Board for 4 seconds. The ‘High’ LED D20 will flash. — Set the CCR to the MEDIUM intensity setting, verify that the MEDIUM LED D19 is lit. — Set the CCR to the HIGH intensity setting, verify that the HIGH LED D20 is lit. Schematics — Set the CCR to the desired intensity setting, verify that the desired intensity LED Dxx is lit. NOTE: Only the primary unit is programmed. The secondary unit must not be programmed. 14 © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment Examples of allowed current settings Current Not Used B5 Current 6.6 A Not Used 3.4 A MED B4 B5 B5 Current 3.4 A 3.4 A 2.8 A B1 B2 B3 B4 B5 CCR Output Schematics Parts Operation 3-Step B3 B4 NOTE: The current-range between 6.6steps must be the same, A HI therefore the REIL steps will be setup for B1/B3/B5 or grouped 6.6 A HI together as shown in the top two graphs. LOW CCR Output B3 CCR Output MED 2.8 A B2 B2 MED Not Used B1 B1 Safety B4 B3 CCR Output Installation Introduction L-849A/E REIL: Required Equipment B2 3-Step B1 Table of Contents Not Used 2.8 A 3-Step 3-Step Not Used HI LOW 2.8 A LOW 3.4 A MED LOW 3.4 A MED 6.6 A HI Current 6.6 A HI Not Used Disclaimer Figure 7: © 2012 ADB Airfield Solutions All Rights Reserved 15 L-849 Voltage/Current, Style A and E L-849A/E REIL: Required Equipment 96A0381 Rev. L 11/26/12 Disclaimer Table of Contents Safety Introduction Installation L-849A/E REIL: Required Equipment Operation Parts Schematics 16 © 2012 ADB Airfield Solutions All Rights Reserved L-849 Voltage/Current, Style A and E Operation 4.0 Operation This section provides instructions for operating the L-849A/E, Voltage/Current (V/I) Runway End Identifier Lights (REIL). WARNING Read the instructions in their entirety before operating the REIL. Disclaimer 96A0381 Rev. L 11/26/12 Allow only qualified personnel to perform the following tasks. The L-849 REIL system may be operated by local or remote control. Remote control is by switch or radio receiver/decoder unit. For maintenance purposes, a rotary selector switch is provided inside the Primary individual control cabinet for local control. 4.1 Operational Modes Refer to Table 7 and Table 8. A rotary selector switch is in the L-849A/E, Voltage/Current (V/I) individual control cabinet. L-849 style A has 3 settings (REMOTE, OFF and, ON) and the L-849 style E has 5 settings (REMOTE, OFF, LOW, MEDIUM and, HIGH). These settings control the flashing lights locally or turn control of the lights over to a remote location. The REMOTE setting on the rotary selector switch turns control of the system over to a remote control system that can turn the flashing lights on or off. Table 7: L-849 Voltage and Current, Style A REIL Modes of Operation Remote Control Panel Setting Operational Results OFF All Settings System off – no flashing ON All settings Flashers operate REMOTE OFF System off – (except when current sensing is present) REMOTE ON Flashers operate Remote Control Panel Setting Operational Results OFF All Settings System off – no flashing ON Any Flashers operate REMOTE OFF System off – no flashing REMOTE ON (low, medium, high) Flashers operate Figure 8: Example allowed current settings for 3-step REIL, L-849 “E” Current 6.6 A HI Not Used Current 6.6 A HI Note: 3.4 A MED 3.4 A MED Not Used B2 B3 B4 B5 CCR Output © 2012 ADB Airfield Solutions All Rights Reserved 3-Step 3-Step Not Used 2.8 A B1 The current-range between steps must be the same, therefore the REIL steps will be setup for B1/B3/B5 or grouped together such as, B1/B2/B3. 2.8 A LOW Not Used LOW Parts L-849 Voltage and Current, Style E REIL Modes of Operation Rotary Switch Position (Primary Cabinet) Schematics Table 8: Operation Rotary Switch Position (Primary Cabinet) B1 B2 B3 B4 Installation Introduction Operation This section provides instructions for operating the L-849A/E, Voltage/Current (V/I), REIL. Safety Table of Contents Observe and follow the safety instructions in this document and all other related documentation. B5 CCR Output 17 L-849 Voltage/Current, Style A and E Operating Procedures 96A0381 Rev. L 11/26/12 Disclaimer 4.2 Operating Procedures This subsection provides information on the L-849A/E, V (voltage driven) procedure. 4.2.1 REIL Startup Procedure See Figure 9 and the guidelines below: 1. Set the ON/OFF switch S1 on the input module in both the Primary and Secondary control cabinet to the ON position. Table of Contents 2. Set the rotary control switch in both control cabinets to either: • • REMOTE position for remote (voltage only) or current sensing operation ON position for local operation 3. Make sure that both control cabinet doors are properly closed to activate interlock switch S3 on the door. Safety 4. If remote operation, make sure that the remote control switch is set to the REMOTE position. NOTE: For the voltage powered L849 REIL: The system should start flashing when the external circuit breaker is in the ON position supplying power to both control cabinets. Introduction Installation Operating Procedures For the current powered L849 REIL: The system should start flashing when the series circuit is energized for both units at the desired current step set in the procedure in “Initial Startup and Preliminary Test” on page 13. Figure 9: Switch and Fuse Panel (L-849V A shown) Secondary Unit Primary Unit Operation Parts 4.2.2 Changing Step Modes (Primary only) Changing from a 3-step setting to a single-step setting: • Press the CURRENT ADJUST button SET HIGH for 4 seconds. The HIGH LED will blink for 2 seconds and turn off. Schematics Changing from a 1-step setting to a 3-step setting: • Press the CURRENT ADJUST button SET LOW, SET MED and SET HIGH buttons simultaneously for 4 seconds. The LOW, MED, and HIGH LEDs will blink for 2 seconds and then turn off. NOTE: Only the Primary Unit requires programming. 4.2.3 Shutdown Procedure When it is necessary to shut down the control cabinets, open the cabinet door and place the ON/OFF switch to the OFF position. The switch is located in the upper right hand corner of the cabinet enclosure behind the door. When the entire system is to be shut down: • • 18 L-849I: Put the ON/OFF switch in both control cabinets in the OFF position. L-849V: Turn the CCR off. Put the ON/OFF switch in both control cabinets in the OFF position. Put the external circuit breaker in the OFF position. © 2012 ADB Airfield Solutions All Rights Reserved 5.0 Maintenance and Repair This section provides preventive maintenance for L-849 Runway End Identifier Lights (REIL) system. WARNING Read the instructions in their entirety before starting any maintenance activities. Disconnect power to the lighting circuit before attempting to make any electrical repairs. Coordinate a power outage with air traffic personnel before turning off power to the airport lighting system. Allow only qualified personnel to perform the following tasks. Disclaimer L-849 Voltage/Current, Style A and E Maintenance and Repair Table of Contents 96A0381 Rev. L 11/26/12 To keep the L-849 REIL system operating efficiently, follow a preventive maintenance schedule. Refer to Table 9. Bimonthly Monthly Semi-Annually Annually Check LED operation and flashing sequence. Installation Introduction Maintenance and Repair Daily Maintenance Task Action If flashing malfunctions, follow Trouble Shooting Procedures in Section 6. Check operation of controls. If controls malfunction, replace controls. Check cleanliness of front glass. If dirty, clean front glass as required. Check operation of interlocks. If interlocks malfunction, replace interlocks. Check for vegetation or other obstruction near LED engine. Use herbicide or manually to remove vegetation. Check cabinets for cleanliness and moisture. If cabinets are moist, wipe dry. Check seals on enclosures. Replace worn or deteriorated seals. Check electrical connections and terminal block contacts for tightness. If connections are loose, repair or replace. Check cabinet vertical and horizontal alignment. Realign cabinet if needed. Check wires for cracks and deterioration. If wires are cracked or deteriorated, replace wires. Check for rigidity of support structures. Tighten all mounting hardware. Verify incoming power is within tolerance. Calibrate or repair power distribution equipment if needed. Operation Interval L-849 REIL Maintenance Maintenance Table 9: Check insulation resistance of external interconnection If reading is less than 50M ohms at 1000VDC, replace wiring. wiring. Check resistance of grounding system. If resistance is greater than 25 ohms to earth, take steps necessary to lower resistance. Check need for painting. Touch up any painted surface. 5.1.1 Replacing LED PCB Assembly To remove and replace the LED PCB Assembly see Figure 10 and then proceed as follows NOTE: Individual LED’s cannot be replaced. 1. Turn the power off in the control cabinet by placing the On/Off service switch in the OFF position or by disengaging the external circuit breaker. De-energize and lockout incoming power. 2. Remove the screws that secure the Optical Glass Assembly to the front of the enclosure. 3. Remove the Optical Glass Assembly and gasket from the enclosure. Disconnect the leads to the LED Panel Assembly. CAUTION Note the polarity of each individual LED panel before removing any panel. Polarity is marked on the face of the LED PCB. If all four (4) individual LED Panel Assemblies are to be replaced, replace one panel assembly at a time. 4. Remove the LED Panel Assembly. © 2012 ADB Airfield Solutions All Rights Reserved 19 Schematics 5.1 Maintenance Schedule Safety Observe and follow the safety instructions in this document and all other related documentation. L-849 Voltage/Current, Style A and E Maintenance Schedule 96A0381 Rev. L 11/26/12 Disclaimer 5. Remove the faulty individual LED panel, if more than one is faulty, remove one at a time. See Figure 10. 6. Install the new LED Panel Assembly insuring that the polarity is the same as the removed panel. Reconnect the power leads to the panel assembly. 7. Apply 67A0033 Thermal-joint Compound between the LED PCB and the mounting plate. Table of Contents 8. Before reinstalling the Optical Glass Assembly check the gasket for any signs of deterioration such as cracks or tears. If the gasket is damaged, replace with a new gasket. 9. Install all of the mounting screws used to fasten the Optical Glass Assembly to the enclosure face. Ensure that all screws are tight. 10. Restore power to return the unit to service. Figure 10: LED Engine PCB Replacement Safety Remove (16) screws to remove the front Introduction Installation Maintenance Schedule Operation Removal of all 4 LED Panel Assemblies can be accomplished by removing the (4) screws found in the corners of the LED mounting panel. Maintenance Removal of each individual LED panel assemblies can be accomplished by removing the (6) screws securing the LED panel to the mounting panel. Schematics 5.1.2 Troubleshooting This section provides troubleshooting information for the L-849V/I, Style A/E LED Runway End Identifier Lights (REIL) system. This information covers only the most common problems that may be encountered. If the problem cannot be solved with the information given here, contact the ADB Airfield Solutions Service department for assistance. WARNING Read the instructions in their entirety before starting any repair activities. When it is absolutely mandatory that the door interlock be bypassed to trace a fault or correct a malfunction, authorized maintenance personnel may perform the bypass by pulling the interlock out toward you for the specific test to be made. Immediately after completing the test, the interlock shall be restored to working condition. When the current sensing option is present, turning the rotary switch S2 to OFF does not remove power to the flashers unless both the ON/OFF switch S1 is turned to OFF and the CCR connected to the isolation transformer is also turned off. 20 © 2012 ADB Airfield Solutions All Rights Reserved Problem REIL Troubleshooting Procedures Possible Cause Solution L-849V: Check voltage at terminal block TB1 terminals 14 and 15. No input power L-849I: Verify input current is present at TB1 terminals 14 and 15. Replace fuse. Determine why fuse has blown and repair. L-849V: External circuit breaker trips each time it is turned on Lightning arrestor V1 or V2 is shorted. Replace lightning arrestor. No power to Flasher Control Board. Fuse F3 blown. Replace F3. Secondary unit is turned off. Turn Secondary unit ON Blown F1, F2 or F3 fuse in non-flashing unit. Replace fuse. Determine why fuse has blown and repair. LED Optical Assembly defective. Replace Optical Assembly. Current driven REIL- Failed Power Supply PS5. Verify that 240VDC is present at PS5 terminals E5 (+) to E6 (-). Replace power supply if correct voltage is not present. Flasher Control PCB failed. Replace PCB. Loose external wire connection. With the power off and using an ohmmeter, check continuity of each wire. Flasher Control PCB failing. Replace Flasher Control PCB. LED Optical Assembly failing Replace the assembly. 4. Operates in Local control but not In Remote Fuse F4 blown. No 120VDC is present for remote control signals. Replace F4. Determine reason for short in external remote control circuitry. 5. Light output is dimmer in one of the Flashers. One of the LED Power Supply PCBs, PS1, PS2, PS3 or PS4 has failed. Installation Introduction Maintenance Schedule 2. One individual control cabinet flashes, but the other one does not Safety Blown fuse F1 or F2 in Primary Cabinet 1. No flashing in either individual control cabinets 3. Light flashes intermittently Device voltage Current On/Off Switch Designation S1 S1 Panel Fuse F1, F2 S1 Panel Fuse F3 S1 Panel Fuse F4 S1 Panel Fuse F1, F2 S1 Panel Fuse F3 S1 Panel Fuse F4 © 2012 ADB Airfield Solutions All Rights Reserved Maintenance On the suspected failing board, verify presence of 70VDC ± 5VDC at J2 + to -. Replace board if voltage is incorrect. Protection Devices Value -- 10A, Slow Blow P/N 47A0026 2A, 250V,Slow Blow P/N 47A0049 1A, Slow Blow P/N 47A0017 2A, 250V,Slow Blow P/N 47A0049 2A, 250V,Slow Blow P/N 47A0004 1A, Slow Blow P/N 47A0017 Function Schematics Table 11: Table of Contents Table 10: Disclaimer L-849 Voltage/Current, Style A and E Maintenance Schedule Operation 96A0381 Rev. L 11/26/12 Incoming power switch. Illuminates red if input power is present. Incoming power protection. Protection on the 240VDC output of Power Supply PS5. 120VDC remote control source protection. Incoming power protection. Protection on the 120Vac secondary of T1, terminals 6-7. 120VDC remote control source protection. 21 L-849 Voltage/Current, Style A and E Maintenance Schedule Disclaimer Device 96A0381 Rev. L 11/26/12 Designation Value Function Control Board Fuse F1 1A, 250V, Slow Blow, 3AG, P/N 47A0017 Incoming power protection on the Control Board, 47A6724 or 47A6724-C. Flasher Power Supply Board Fuse F1 2A, 250V, Slow Blow, 5x20mm, 47A0215 Incoming power protection on the Flasher Power Supply Board, 47A6545. Table of Contents Figure 11: Flasher Control PCB 44A6724 Operation D23 LED Fault D21 Power On LED J4 6.000 J7 1 J8 1 J4 J7 J9 NO NO 1 1 R66 1 C19 D29 R65 J6 PS1 - PS4 On LEDs 1 RP1 - D24 D26 D28 D30 Remote Indication LEDs C12 C11 Q4 + RP4 D5 D4 R16 REMOTE LOW REMOTE MED Q3 C10 C9 1 C1 R3 C2 C3 R6 C4 C5 R9 C6 C8 C7 R12 C14 R25 C15 1 Q2 Q1 + PS4 ON PS3 ON PS2 ON R15 D3 D2 R14 REMOTE HI REMOTE ON Q5 R13 C13 R17 + R36 C18 D27 R64 Current Adj R31 R35 R34 D25 R37 PS1 ON ROTARY SWITCH R30 C17 C16 D16 R59 R22 D1 D6 U4 1 1 DB1 J6 U1 R21 D7 TRIGGERDRV1 R19 R58 TRIGGERDRV2 C34 C37 C35 C36 RP2 C29 ~ D30 R28 R33 C39 POWER ON 1 RP3 1'S C27 C28 2 J5 ~ TRIGGER-IN C38 X1 1 1 D28 D26 D24 R26 C42 R57 D21 LED FAULT R56 Q11 R53 R39 MISFIRE THRESHOLD C22 R38 Trigger LEDs R48 R49 U3 Q6 C25 U2 F1 R10 R7 R4 R1 MV5 R27 R32 R67 D12 D10 3 R23 TVS1 4 D13 R46 C32 C30 1 R2 R5 R8 R24 C21 R11 R29 R47 R50 Q7 U9 D17 HIGH U10 U7 Misfire Threshold D20 D19 R55 Q10 R52 R54 Q9 MEDIUM SW1 C26 D23 SW4 D18 R51 C24 R41 Introduction Installation Maintenance Schedule LOW SET HIGH R63 SW3 34 5 2 6 10 7 D18 D19 D20 R62 R61 R40 C23 SW2 C40 C33 C31 U6 SET MEDIUM C43 C41 Q13 CURRENT ADJUST U5 SW1 R60 TP1 SET LOW J2 1 U11 - R45 R43 R44 K1 TVS2 D22 1 + Safety Q12 Q8 SW2 SW3 SW4 J2 1 J8 R42 U8 J9 1 MV4 D14 D8 MV8 MV3 C20 MV6 MV2 1 T1 R18 R20 2 D15 D9 Operation MV7 MV1 J3 REV MADE IN U.S.A. 1 0 1 J3 J1 7.000 0 Maintenance NOTE # 3 Table 12: ID Schematics 22 Name Control Board Controls and Indicators Indication D1 Trigger Driver 1 Green D6 Trigger Driver 2 OFF CAUTION! CONTENTS STATIC-SENSITIVE. OBSERVE ESD PRECAUTIONS. TRANSFER IN ESD PACKAGING. J1 ASSY #44A6724 Description Activated on the Primary Unit only. Flashes when a trigger pulse is output from the Primary Unit. Not used for REIL applications. D7 Trigger In Green Activated on the Secondary Unit only. Flashes when a trigger pulse is received from the Primary Unit. D2 Remote On Green Illuminates when a Remote-On command has been input into the unit. D3 Remote Hi Green Illuminates when a Remote-High intensity command has been input into the unit. D4 Remote Med Green D5 Remote Low Green D16 PS1 On Green D25 PS2 On Green Illuminates when a Remote-Medium intensity command has been input into the unit. Not used in a Style A REIL. Illuminates when a Remote-Low intensity command has been input into the unit. Not used in a Style A REIL. Illuminates when power is being output to LED Power Supply PS1. Illuminates when power is being output to LED Power Supply PS2. Not used in a Style A REIL © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 D27 PS3 On Green D29 PS4 On Green Description Disclaimer Indication Illuminates when power is being output to LED Power Supply PS3. Not used in a Style A REIL. Illuminates when power is being output to LED Power Supply PS4. Not used in a Style A REIL. Table of Contents Name Position 0 - Turns off fault tracking / produces no fault indication. SW1 Misfire Threshold D23 LED Fault Position 1 - 7 sets the fault count, which is the number of misfires per 100 consecutive flashes. Misfires beyond the switch setting will activate the output fault contact closure and will illuminate LED D23. -- Green Dependant on the position of SW1 - illuminates on the fault count selected. Low intensity Current Sensing adjustment control. Low -- SW3 Med -- SW4 High -- D18 Low Green Illuminates when the circuit is operating in the Low current setting and operating within the proper current range. Not used in a Style A REIL. D19 Medium Green Illuminates when the circuit is operating in the Medium current setting and operating within the proper current range. Not used in a Style A REIL. D20 High Green Illuminates when the circuit is operating in the High current setting and operating within the proper current range. D21 Power On Green Illuminates when the +5VDC power supply is operating properly on the Control board. Safety SW2 Not used in a Style A REIL. Medium intensity Current Sensing adjustment control. Not used in a Style A REIL. High intensity Current Sensing adjustment control. Figure 12: Current Driven Type A/E, LED REIL Interior Assembly PS1 44A6545 Operation Current Driven Power Supply PCB 44A7107/1 6.6 A input 240 Vdc output Installation Introduction Maintenance Schedule ID L-849 Voltage/Current, Style A and E Maintenance Schedule Schematics Maintenance Flasher Control PCB 44A6724/C S1 Panel Assembly for the Primary TB1 © 2012 ADB Airfield Solutions All Rights Reserved 23 L-849 Voltage/Current, Style A and E Maintenance Schedule 96A0381 Rev. L 11/26/12 Disclaimer Figure 13: Voltage Driven Type A/E, LED REIL Interior Assembly Table of Contents Safety Introduction Installation Maintenance Schedule Operation Maintenance Schematics 24 © 2012 ADB Airfield Solutions All Rights Reserved L-849 Voltage/Current, Style A and E Parts 6.0 Parts To order parts, call ADB Airfield Solutions Customer Service or your local representative. Use the parts lists, and the accompanying illustration, to describe and locate parts correctly. 6.1 849A/E REIL Ordering Code Numbering System Figure 14: Ordering Code Number Chart Table of Contents REIL - X X X X X 0 X 0 Disclaimer 96A0381 Rev. L 11/26/12 Safety ENCLOSURE TYPE 1 = Steel – painted aviation orange 2 = Stainless Steel (not ETL certified) Installation Introduction Parts ENCLOSURE MOUNTING 1 = Single Leg (recommended for voltage powered w/o current sensing only) 2 = Two Legs FLASH HEAD MOUNTING 0 = Integrated with enclosure 1 = Separate mounting on a 2 inch EMT (Style C only) (see 96A0361) CURRENT SENSING OPTION1 0 = Without 1 = With STYLE A = High Intensity, one brightness step C = Low Intensity, one brightness step (see 96A0361) E = Three brightness steps 1. The current sensing option provides ON/OFF control (L-849 Style A/Style C) or 3-step intensity control (L-849 Style E) of the REIL system depending on the current level in the series lighting circuit. The L-849I (powered by a CCR) doesn’t require a separate isolation transformer. (The input current from the isolation transformer that powers the Primary cabinet is also used for current sensing control.) The current sensing input of a L-849V (voltage powered) can be connected to 6.6A or 20A series circuits with an appropriate 6.6/6.6A or 20/6.6A isolation transformer. © 2012 ADB Airfield Solutions All Rights Reserved 25 Parts 2 = L-849V voltage driven Maintenance Operation POWER 1 = L-849I current driven L-849 Voltage/Current, Style A and E 849A/E REIL Ordering Code Numbering System Disclaimer 6.1.1 Control Panel Assembly Part Numbers 96A0381 Rev. L 11/26/12 The following main control panel components are identified below. See numerical parts list for detailed description of parts. Table of Contents Safety Figure 15: Control Panel Assembly (single-leg, voltage shown) Introduction Installation 849A/E REIL Ordering Code Numbering System Solid State Relay (K1) 53A0429 (voltage only) 44A6730-XXXX Complete Panel Assembly Ref – Elevation Adjustment Knob Ref- Interlock Switch 45A0269 LED Flasher Power Supply Assembly 44A6545 44A6745X2XX (voltage) 44A6745X1XX (current) Transformer T1, 240 to 120/24Vac 35A0539 (voltage only) Power Supply Assembly, PS5 44A7107/1 (current only, not shown) Operation Control Board 44A6724 (Voltage) 44A6724-C (Current) Lightning Arrestor, 275VAC 32A0032 Qty = 2 Maintenance Knob 61A0340 Rotary Switch Assembly 44A6166 Switch, DPDT, 10A 45A0267 Parts Fuse F1 to F4 SeeTable 14 for part numbers NOTE: See the Numerical and Spare Parts List for part numbers for full description on each of the labeled parts The same control panel is used in each individual control cabinet. 26 © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E 849A/E REIL Ordering Code Numbering System Control Panel Assembly (duel-leg, current unit shown) Disclaimer Figure 16: Ref – Elevation Adjustment Knob Power Supply Assembly, PS5 44A7107/1 Table of Contents 44A6730-XXXX Complete Panel Assembly Ref- Interlock Switch 45A0269 Safety LED Flasher Power Supply Assembly 44A6745X1XX (current) Installation Introduction 849A/E REIL Ordering Code Numbering System Control Board 44A6724-C (Current) Lightning Arrestor, 275VAC 32A0032 Qty = 2 Operation Fuse F1 to F4 SeeTable 14 for part numbers Rotary Switch Assembly 44A6166 Maintenance Switch, DPDT, 10A 45A0267 The main components of the optical assembly are identified below. See the numerical parts list for detailed description of parts. Figure 17: Parts 6.1.2 Optical Assembly Part Numbers Optical Assembly Components 44A6723 60A3290-2 60A3290-1 © 2012 ADB Airfield Solutions All Rights Reserved 27 L-849 Voltage/Current, Style A and E 849A/E REIL Ordering Code Numbering System Disclaimer 6.1.3 L-849V/I, Style A/E Assembly Part Number 96A0381 Rev. L 11/26/12 The main assembly, 44A6726-XXXX, is composed of an integrated head and power supply enclosure, a single or dual leg assembly, and a frangible coupling for each leg as identified below. Figure 18: Complete Assembly – Single Leg Mounting Shown Gasket 63A1104 Table of Contents Front Glass Assembly 63A1098-1 1 = N/A Safety Introduction Installation 849A/E REIL Ordering Code Numbering System 2" Frangible Coupling 62B0064 Table 13: Part Number Other Main Assembly Parts Description Quantity Notes 45A0269 Interlock Switch, SPST, 10A, ON-OFF-ON 1 Shown in Figure 15 77A0009 Compression Coupling, 2” EMT 2 For Dual Leg Mounting Option 44B0180 Frangible Coupling, 2” EMT 2 For Dual Leg Mounting Option Operation Maintenance Parts 28 © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 Lightning Arrestor 275Vac 4 44A6724 Control Board Assembly 1 Used on voltage powered REIL only 44A6724-C Control Board Assembly 1 Used on current powered REIL only 44A6545 LED Flasher Power Supply Assembly 2 44A6631 Power Supply Assembly, PS5 1 Used on Current Powered REIL only 53A0429 Solid State Relay, 24-250Vac, 5-24Vdc 1 Used on voltage powered REIL only 45A0269 Interlock Switch, Door, SPST, 10A 1 62B0064 2-inch frangible coupling 1 Used on single leg units only 77A0009 Compression Coupling, 2” EMT 2 Used on dual leg units only 44B0180 Frangible Coupling, 2” EMT 2 Used on dual leg units only Fuse, Panel, F1 and F2, 10A, SB 4 Used on current powered REIL only Fuse, Panel, F3, 2A, SB 2 Used on current powered REIL only Fuse, Panel, F4, 1A, SB 2 Fuse, Panel, F1 and F2, 4A, SB 4 Used on voltage powered REIL only Fuse, Panel, F3, 2A, SB 2 Used on voltage powered REIL only 47A0017 Fuse, Control Board, F1, 1A, SB 2 47A0215 Fuse, Flasher Power Supply Board, F1, 1A, SB 4 See table 6.3 Table 15: Part Number REIL A/E Parts, Voltage Powered Description Quantity Notes 32A0032 Lightning Arrestor 275Vac 4 44A6724 Control Board Assembly 1 44A6545 LED Flasher Power Supply Assembly 1 62B0064 2-inch frangible coupling 1 Used on single leg units only 77A0009 Compression Coupling, 2” EMT 2 Used on dual leg units only 44B0180 Frangible Coupling, 2” EMT 2 Used on dual leg units only Fuse, Panel, F4, 1A, SB 2 Fuse, Panel, F1 and F2, 4A, SB 4 Used on voltage powered REIL only Fuse, Panel, F3, 2A, SB 2 Used on voltage powered REIL only 47A0017 Fuse, Control Board, F1, 1A, SB 2 47A0215 Fuse, Flasher Power Supply Board, F1, 1A, SB 4 See table 6.3 © 2012 ADB Airfield Solutions All Rights Reserved Disclaimer 32A0032 Table of Contents Notes Safety Quantity Installation Introduction Numerical Parts Lists Description Operation Part Number REIL A/E Parts, Current Powered Maintenance Table 14: Used on voltage powered REIL only Parts 6.2 Numerical Parts Lists L-849 Voltage/Current, Style A and E Numerical Parts Lists 29 L-849 Voltage/Current, Style A and E Numerical Parts Lists 96A0381 Rev. L 11/26/12 Disclaimer Table 16: REIL A/E Parts, Current Powered Part Number Description 32A0032 Lightning Arrestor 275Vac 44A6724-C Control Board Assembly Quantity Notes 4 1 Used on current powered REIL only Table of Contents Safety 44A6545 LED Flasher Power Supply Assembly 1 44A6631 Power Supply Assembly, PS5 1 62B0064 2-inch frangible coupling 1 Used on single leg units only 77A0009 Compression Coupling, 2” EMT 2 Used on dual leg units only 44B0180 Frangible Coupling, 2” EMT 2 Used on dual leg units only Fuse, Panel, F1 and F2, 10A, SB 4 Used on current powered REIL only Fuse, Panel, F3, 2A, SB 2 Used on current powered REIL only See table 6.3 Introduction Installation Numerical Parts Lists Fuse, Panel, F4, 1A, SB 2 47A0017 Fuse, Control Board, F1, 1A, SB 2 47A0215 Fuse, Flasher Power Supply Board, F1, 1A, SB 4 Table 17: Used on Current Powered REIL only S1 Panel Assembly Fuses Fuse Current Driven Voltage Powered Quantity F1 47A0026 47A0078 F2 47A0026 47A0078 F3 47A0049 47A0004 2 F4 47A0017 47A0017 2 4 Operation Maintenance Parts 30 © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 Voltage/Current, Style A and E Schematics L-849A/E LED Flasher (REIL) CTRL Box External Wiring Diagram (Voltage Driven) NEU 1400 Feet 10 900 Feet 12 EARTH VAC IN-2 SPARE VAC IN-1 SPARE Minimum AWG Wire Size to Use 14 600 Feet 16 NOTE: If power adapter is used, use AWG 12, 600V. Installation Introduction Schematics Safety TB1-17 TB1-16 TB1-15 TB1-14 TB1-13 400 Feet TB1-12 TRIGGER IN TRIG-OUT-1 TB1-11 TB1-9120VDC RETURN TB1-10 HI MED 120VDC TB1-8 TB1-7 LOW TB1-5 TB1-6 FAIL N.C. TB1-3 FAIL COM FAIL N.O. NOTE 2 TB1-2 TB1-1 TB1-18 TB1-19 NEU EARTH TB1-16 TB1-17 VAC IN-2 VAC IN-1 TB1-14 TB1-15 SPARE SPARE TB1-13 TB1-12 TRIGGER IN TRIG-OUT-1 TB1-11 TB1-9120VDC RETURN TB1-10 HI 120VDC TB1-8 TB1-7 MED LOW TB1-5 TB1-6 FAIL N.C. TB1-3 TB1-4 IDENTIFIERS ON FAIL COM FAIL N.O. TB1-1 Example of Fail Indicator using internal Fail Relay. TB1-2 Fail Indicator MAX 250VAC/DC 5A Table 1. External Power AWG Wire Size Distance from Transformer to Master Individual Control Cabinet "SECONDARY" "PRIMARY" 5A L-849A (Hi Intensity) SWITCH WIRING LED FLASHER BOX #2 Table of Contents LED FLASHER BOX #1 TB1-4 IDENTIFIERS ON Figure 19: Disclaimer 7.0 Schematics L-849E SWITCH WIRING Remote High Remote High Control Remote Medium and High Optional Current Sensing Connection: L-830-1 (6.6A) L-831-2 (20A) Remote Medium and High Control Remote On / Off Remote 120VDC Remote On (Low) /Off Control Remote 120VDC Operation Remote On /Off Control Remote On (Low)/Off Remote Control Switch or Relay Contact (supplied by others). Shall not be used if optional current sensing is present. External circuit breaker (supplied by others) 120 Vac 240VAC OR 120V/240VAC, ±10,, 50/60Hz, (connected to transformer or power adapter. See Input Wiring Table.) DATE: ADB E 3228 CHG LOGO JLC 14APR11 D --- DWG. CLARIFICATIONS AND BE 15OCT07 C --- BE 11OCT07 B --- REMOVED PG. 2 (MALSR) BE 10OCT07 A --- NEW (WAS 43A3158) BE 14MAR07 DRAWN BY REV DATE ADB Airfield Solutions 977 Gahanna Parkway, Columbus, Ohio 43230 Telephone: 614-861-1304, Fax: 614-864-2069 NEW DWG. NO. SEE 43A3320/V REV LEVEL ECO NUMBER ASSOCIATED DRAWINGS: DWG. CLARIFICATIONS REVISION DESCRIPTION DRAWN BY: DRAWN DATE: BE 14MAR07 Information contained on this drawing is to be used expressly in accord with purpose for which it was submitted. Any disclosure of this information is strictly prohibited except as ADB Airfield Solutions, Inc. may otherwise agree in writing. Copyright 2007 © 2012 ADB Airfield Solutions All Rights Reserved Schematics (NEU) (EARTH) TB1-17 TB1-16 (VAC IN-2) CONTROLLED COPY Unauthorized duplication of this document in whole or part is prohibited. Initialed in RED ink below indicatesauthorized copy. APPROVED BY: NOT USED EARTH (VAC IN-1) TB1-14 TB1-15 240V HOT 240V NEUTRAL (EARTH) (NEU) (VAC IN-2) TB1-15 TB1-17 EARTH NEUTRAL NOTE: 240VAC IS PRESENT FROM TB1-14 TO TB1-15. 240V L2-120V 120/240V L1-120V Neutral Power Adapter 6.6 A : 120/240VAC TB1-16 L1-120 Vac (VAC IN-1) Runway Lighting Loop (6.6 A) TB1-14 INPUT WIRING TABLE: Optional Power Adapter Connections for Legacy Installations (ADB recommends using Current Powered REIL without Power Adapter) L2-120 Vac Parts NOTES: 1. Ground each individual control cabinet at external earth ground lug as indicated in installation section of instruction manual. 2. TB1 terminal blocks 18 & 19 added for "monitoring" option only. 3. Unless otherwise specified, all wires are 16 AWG, 600V. Neutral Refer to Table 1 for AWG size. All wires 600V. To Master Individual Control Cabinet Parts 120 Vac DRAWING TITLE: L-849A/E LED FLASHER (REIL) CTRL BOX EXTERNAL WIRING DIAGRAM (VOLTAGE DRIVEN) SCALE: N/A SHEET NUMBER: DRAWING NUMBER: 43A3319/EXT/V 1 OF 1 REV. E 31 L-849 Voltage/Current, Style A and E Schematics Disclaimer Figure 20: 96A0381 Rev. L 11/26/12 L-849A/E (Voltage) LED Flasher CTRL Box Internal Wiring Diagram Table of Contents NOTES: 1) WIRE NOS & SIZES: 5XX WIRE: 18AWG, 600V, 200C, WHT. (89A0073/9) 7XX WIRE: 20AWG, 600V, 200C, WHT. (89A0004/9) 9XX WIRE: GND, 14AWG, GRN/YEL, 600V, 105C (89A0163/4) 2) INPUT TERMINAL BLOCKS 14 - 17 ARE (20-6) AWG. BLOCKS. 3) FOR "SECONDARY" UNIT: WIRE J6 JUMPERS AS SHOWN - ROTARY SWITCH IS NOT USED. ALSO ADD 30K, 5W RESISTOR PER MODIFICATION DWG. BOX BELOW. 4) FOR "L-849E" ONLY: REMOVE HARNESS JUMPER FROM TB1-4 TO 7. LED PANELS: 4 STRINGS TO EACH PANEL (A-D) A B C D 701A A 702A B (+) C 703A (LED PANEL CONNECTOR) PLUGS, WIRING SIDE) 704A A A B (+) C B (-) C D A B (-) C D D A A B (+) C D B (-) C D A 703B B (-) C 704B D 702B A B (+) C D D 701B FCB 538 TB1-9 Parts TB1-10 RED 10 GRY 9 GRN/YEL 532 3 BLACK 4 8 VIO 531 7 BRN 534 12V LINE 534 120V 5 515 J1A1 SWITCH "STOP" SETTINGS: "L849E" = BETWEEN 1 & 12 AND BETWEEN 5 & 6. (1A-SB) (2A-FB) 542 701A 545 TO FCB-J2-1 J1 L N PS2 + _ 44A6545 J2 (BOTTOM SIDE) 554 FCB 509 LINE 8 7 6 5 4 3 2 1 J6 JUMPERS (3) FOR "SECONDARY" UNIT CONNECTIONS (NO ROTARY SWITCH) TO FCB-J2-2 J1 L N PS3 + _ 44A6545 J2 J6 555 RED F4 508 533 F3 J6 505 506 507 504 904 543 1 2 529 509 528 RED/BLK 520 523 521 522 1 2 3 4 5 6 7 8 J1 BLUE 533 BLACK 537 902 522 703A 547 (35A0539) 521 523 520 10 9 8 7 6 5 4 3 2 1 8 76 5 4 3 2 1 531 532 565 566 Operation 528 J3 CURRENT SENSING OPTION CONNECTIONS 515 8 7 6 5 4 3 2 1 702A 546 3 4 5 2 6 1 7 TO "PS1-J1-1" (N) "PRIMARY" ROTARY SWITCH CONNECTIONS FOR "L-849E" SW4 MISFIRE THRESHOLD T1 + _ J2 SET HIGH SET MEDIUM SW3 SW2 (FLASHER CONTROL BD.) 44A6724 542 PS1 44A6545 553 SET LOW INPUT + 3 (BOTTOM SIDE) NOTE 3 4 J2 SW1 SWITCH "STOP" SETTINGS: "L849A" = BETWEEN 1 & 12 AND BETWEEN 3 & 4. FOR "SECONDARY" UNITS ONLY: ADD 30K, 5W RESISTOR ACROSS TB'S 9 & 10. J9 J8 3 557 J1A1 2 1 559 515 4 4 560 558 559 522 - 3 CURRENT ADJUST 564 521 1 2 3 4 5 6 7 8 L N J9 2 1 J7 J4 K1 563 522 1 2 562 560 561 (NEU) (EARTH) (VAC IN-2) TB1-17 TB1-15 TB1-16 (VAC IN-1) TB1-14 NOT USED EARTH 240V NEU 240V HOT (NEU) (EARTH) TB1-17 (VAC IN-2) TB1-16 EARTH (VAC IN-1) TB1-15 NEUTRAL 521 J1 1 2 3 4 5 6 78 2 LOAD ROTARY SWITCH ROTARY SWITCH J6 "PRIMARY" ROTARY SWITCH CONNECTIONS FOR "L-849A" 515 558 544 557 543 1 8 7 6 5 4 3 2 1 542: TO "T1-1" (BLK) 544: TO "K1-1" TO PS1-J2: 553 TO PS2-J2: 554 TO PS3-J2: 555 TO PS4-J2: 556 TO TB1-3 503 502 501 544 563 564 L2-120V 240V TO "PS1-J1-2" (L) 701B 702B 703B 704B 545 546 547 548 Introduction Installation Schematics L1-120V NOTE: 240VAC IS PRESENT FROM TB1-14 TO TB1-15 0 Safety 120/240V TB1-14 INPUT WIRING TABLE: TO FCB-J2-3 562 561 6 BLUE JUMPER FOR L-849A, REMOVE FOR L-849E WIRES TO FCB-J8 LED FLASHER L-849A/E EXT. VOLT. WIRING DIAGRAM LED FLASHER (REIL) FINAL ASSY. LED FLASHER COMPONENT PLATE ASSY. DESCRIPTION RELATED DOCUMENTS 32 JUMPER FOR 'REMOTE' TEST ONLY, REMOVE WHEN DONE TB1 906 704A 548 556 CONTROLLED COPY Unauthorized duplication of this document in whole or part is prohibited. Initialed in RED ink below indicatesauthorized copy. TB1-19 TB1-18 907 TB1-17 TB1-16 TB1-15 TB1-14 TB1-13 TB1-12 TB1-11 SEE INPUT WIRING TABLE & NOTE 2 TO FCB-J2-4 905 903 EARTH 902 NEU VAC IN-2 535 SPARE VAC IN-1 536 529 SPARE TRIGGER IN TRIG-OUT-1 528 902 120VDC HI 120VDC RETURN SEE NOTE 3 J2 PANEL GND. OPTIONAL CURRENT SENSE CONNECTIONS H 3228 CHG LOGO JLC 15APR11 G --- REVISED GND WIRE TO 14AWG BE 06NOV09 F 2137 FUSE CHANGE - SEE ECO BE 22DEC08 E --- ADDED ROTARY SW "A" WIRING BE 10DEC08 D --- DWG. CLARIFICATIONS AND BE 15OCT07 NEW DWG. NO. C --- DWG. CLARIFICATIONS BE 11OCT07 ADDED SWITCH STOP SETTINGS; BE 05SEP07 BE 20APR07 DRAWN BY REV DATE B 1777 A 1777 REV LEVEL ECO NUMBER DOOR GND. 43A3319/EXT/V 44A6557 44A6560 DOC. NO. + _ 44A6545 BOX GND. TB1-10 TB1-3 TB1-2 TB1-1 S1 SHOWN IN THE "OFF" POSITION TB1-9 COM 516 905 PS4 566: TO FCB J3-8 565: TO FCB J3-7 904 507 508 505 506 MED 503 504 LOW NO 2 516 TB1-8 5 6 4 1 TB1-7 (4A-SB) 517 538 TB1-6 F1 JUMPERS (2 PLCS) IDENTIFIERS ON 901 900 540 DOOR CLOSED: ON TB1-5 3 LINE DOOR OPEN: OFF 1 TB1-4 Schematics 2 (4A-SB) SERVICE POSITION: ON 537 541 FAIL N.C. LINE S3 FAIL COM F2 501 V2 V1 539 502 536 535 539 FAIL N.O. Parts 540 DOOR INTERLOCK SWITCH (PULL OUT TO OVERIDE) MAIN PWR "RED" S1 J1 L N CHG'D L849A/E JUMPER NOTE G/Y TERM. BLK. PRODUCTION RELEASE ASSOCIATED DRAWINGS: SEE 43A3319/V REVISION DESCRIPTION DRAWN BY: DRAWN DATE: BE 18APR07 Information contained on this drawing is to be used expressly in accord with purpose for which it was submitted. Any disclosure of this information is strictly prohibited except as ADB Airfield Solutions, Inc. may otherwise agree in writing. Copyright Ó 2007 ADB Airfield Solutions. APPROVED BY: DATE: ADB Airfield Solutions 977 Gahanna Parkway, Columbus, Ohio 43230 Telephone: 614-861-1304, Fax: 614-864-2069 DRAWING TITLE: L-849A/E (VOLTAGE) LED FLASHER CTRL BOX INTERNAL WIRING DIAGRAM (PRI. & SEC.; W/ & W/O MONITORING) SCALE: N/A SHEET NUMBER: DRAWING NUMBER: 1 OF 1 REV. 43A3319/INT/V H © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 LED FLASHER BOX #1 Table of Contents Safety EARTH Parts Operation Installation Introduction Schematics TB1-16 TB1-15 6.6A AC IN-2 SPARE TB1-14 6.6A AC IN-1 SPARE TB1-12 TB1-13 TRIGGER IN TRIG-OUT-1 TB1-11 TB1-8 TB1-10 HI 120VDC TB1-7 TB1-9120VDC RETURN LOW MED FAIL N.C. TB1-3 TB1-6 FAIL N.O. FAIL COM TB1-1 TB1-2 EARTH TB1-16 TB1-15 6.6A AC IN-2 TB1-14 6.6A AC IN-1 SPARE SPARE TB1-12 TB1-13 TRIGGER IN TRIG-OUT-1 TB1-11 TB1-5 "SECONDARY" TB1-10 HI 120VDC TB1-7 TB1-8 TB1-9120VDC RETURN LOW MED TB1-5 TB1-6 FAIL N.C. TB1-3 TB1-4 IDENTIFIERS ON FAIL N.O. FAIL COM Example of Fail Indicator using internal Fail Relay. TB1-2 Fail Indicator TB1-1 MAX 250VAC/DC 5A LED FLASHER BOX #2 "PRIMARY" 5A Disclaimer L-849A/E LED Flasher (REIL) CTRL Box External Wiring Diagram (Current Driven) TB1-4 IDENTIFIERS ON Figure 21: L-849 Voltage/Current, Style A and E Schematics TO L-830 ISOLATION TX, 200W Parts TO L-830 ISOLATION TX, 200W Schematics CONTROLLED COPY NOTES: 1. Ground each individual control cabinet at external earth ground lug as indicated in installation section of instruction manual. 2. All wires 16 AWG, 600V. Unauthorized duplication of this document in whole or part is prohibited. Initialed in RED ink below indicatesauthorized copy. APPROVED BY: DATE: ADB E 3228 CHG LOGO JLC 14APR11 D --- DWG. CLARIFICATIONS AND BE 15OCT07 C --- BE 11OCT07 B --- REMOVED PG. 2 (MALSR) BE 10OCT07 A --- PRODUCTION RELEASE BE 07SEP07 DRAWN BY REV DATE ADB Airfield Solutions 977 Gahanna Parkway, Columbus, Ohio 43230 Telephone: 614-861-1304, Fax: 614-864-2069 NEW DWG. NO. SEE 43A3320/C REV LEVEL ECO NUMBER ASSOCIATED DRAWINGS: DWG. CLARIFICATIONS REVISION DESCRIPTION DRAWN BY: DRAWN DATE: BE 07SEP07 Information contained on this drawing is to be used expressly in accord with purpose for which it was submitted. Any disclosure of this information is strictly prohibited except as ADB Airfield Solutions, Inc. may otherwise agree in writing. Copyright 2007 ADB Airfield Solutions. © 2012 ADB Airfield Solutions All Rights Reserved DRAWING TITLE: L-849A/E LED FLASHER (REIL) CTRL BOX EXTERNAL WIRING DIAGRAM (CURRENT DRIVEN) SCALE: N/A SHEET NUMBER: DRAWING NUMBER: 43A3319/EXT/C 1 OF 1 REV. E 33 L-849 Voltage/Current, Style A and E Schematics L-849A/E (Current) LED Flasher CTRL Box Internal Wiring Diagram (PRI. & SEC.; W/Monitoring) LED PANELS: 4 STRINGS TO EACH PANEL (A-D) A B C D 701A A 702A B (+) C 703A (LED PANEL CONNECTOR) PLUGS, WIRING SIDE) 704A A A B (+) C B (-) C D A B (-) C D D A A B (+) C D B (-) C D A 703B B (-) C 704B D 702B A B (+) C D D 701B Safety 542: TO PS5-E8 J6 515 J7 J4 542 558 543 557 L N J9 3 2 1 J9 4 J8 3 2 1 4 PS1 J2 + _ 44A6545 J1A1 J2 CURRENT ADJUST SET HIGH SET MEDIUM SW3 SW4 SW1 3 4 5 2 6 1 7 MISFIRE THRESHOLD FCB (BOTTOM SIDE) (FLASHER CONTROL BD.) 44A6724/C "PRIMARY" ROTARY SWITCH CONNECTIONS FOR "L-849E" 515 8 7 6 5 4 3 2 1 521 523 520 522 1 2 3 4 5 6 7 8 520 523 521 522 J6 515 553 SET LOW SW2 SET SWITCH "STOP" SETTINGS FOR (3-POS): "L849A" = BETWEEN 1 & 12 AND BETWEEN 3 & 4. J1A1 SET SWITCH "STOP" SETTINGS FOR 5-POS: "L849E" = BETWEEN 1 & 12 AND BETWEEN 5 & 6 TO FCB-J2-1 557 522 1 2 ROTARY SWITCH 1 2 3 4 5 6 7 8 521 543: TO F3 560 558 559 522 1 2 3 4 5 6 78 0 521 503 502 501 ROTARY SWITCH Introduction Installation Schematics 701B 702B 703B 704B 545 546 547 548 TO TB1-3 J1 "PRIMARY" ROTARY SWITCH CONNECTIONS FOR "L-849A" 515 8 7 6 5 4 3 2 1 TO PS1-J2: 553 TO PS2-J2: 554 TO PS3-J2: 555 TO PS4-J2: 556 701A 545 Table of Contents NOTES: 1) WIRE NOS & SIZES: 5XX WIRE: 18AWG, 600V, 200C, WHT. (89A0073/9) 7XX WIRE: 20AWG, 600V, 200C, WHT. (89A0004/9) 9XX WIRE: GND, 14AWG, GRN/YEL, 600V, 105C (89A0163/4) 2) INPUT TERMINAL BLOCKS 14 - 16 ARE (20-6) AWG. BLOCKS. 3) FOR "SECONDARY" UNIT: WIRE J6 JUMPERS AS SHOWN, ROTARY SWITCH IS NOT USED. ALSO ADD 30K, 5W RES. PER MODIFICATION DWG. BOX. 4) FOR "L-849E" ONLY: REMOVE HARNESS JUMPER FROM TB1-4 TO 7. 5) WIRE "PRIMARY SWITCH" FOR EITHER "L-849A" OR "L-849E". J1 L N PS2 + _ 44A6545 J2 LED FLASHER L-849A/E EXT. CURRENT WIRING DIAGRAM LED FLASHER (REIL) FINAL ASSY. LED FLASHER COMPONENT PLATE ASSY. DESCRIPTION RELATED DOCUMENTS 34 TB1 702A 546 554 555 562 561 + _ J2 TO FCB-J2-4 905 556 FOR "SECONDARY" UNITS ONLY: ADD 30K, 5W RESISTOR ACROSS TB'S 9 & 10. CONTROLLED COPY PANEL GND. 528 906 TB1-10 902 TB1-9 TB1-16 TB1-15 TB1-14 TB1-12 TB1-13 TB1-11 PS4 704A 548 904 902 EARTH 6.6A AC IN-2 536 535 6.6A AC IN-1 SPARE SPARE 529 TRIG-OUT-1 TRIGGER IN 905 Unauthorized duplication of this document in whole or part is prohibited. Initialed in RED ink below indicates authorized copy. I 3050 REVISED PS5 PART # BE 05JAN11 H ----- ADDED FERRITE CORE DTR 18AUG10 G ----- REVISED GND WIRE TO 14AWG BE 06NOV09 F 1890 SEE ECO BE 14NOV08 E 1890 UPDATED PS CONNECTIONS BE 06NOV08 D 2005 CORRECTED PCB NO. TO "/C" BE 14AUG08 C 2005 SEE ECO BE 13AUG08 B ----- ADDED JUMPER 571 AND A 1777 PRODUCTION RELEASE DOOR GND. 43A3319/EXT/C 44A6557 44A6730 DOC. NO. TO FCB-J2-3 44A6545 BOX GND. TB1-10 TB1-9 120VDC RETURN 528 508 902 120VDC TB1-8 HI TB1-7 505 506 MED TB1-6 TB1-5 504 LOW TB1-4 IDENTIFIERS ON 503 501 502 507 538 (10A-SB) (10A-SB) 518 TB1-1 540 5 6 4 JUMPERS (2 PLCS) FAIL N.C. JUMPERS (2 PLCS) DOOR CLOSED: (N.O.=ON) 517 901 900 3 TB1-3 1 TB1-2 2 DOOR OPEN: (N.C.=OFF) 516 + _ J2 J1 L N FAIL COM 541 516 F2 FAIL N.O. COM (RED WINDOW IS DOWN) S1 SHOWN IN THE "ON" POS. 518 SERVICE POSITION: (N.O.=ON) MAIN PWR "RED" S1 F1 LINE Schematics 541 536 535 S3 539 PS3 44A6545 JUMPERS (2) FOR L-849A, REMOVE BOTH FOR L-849E WIRES TO FCB-J8 DOOR INTERLOCK SWITCH (PULL OUT TO OVERIDE) V2 V1 L N J6 907 542 532 539 509 LINE J1 J6 JUMPERS (3) FOR "SECONDARY" UNIT CONNECTIONS (NO ROTARY SWITCH) FERRITE CORE 61A0477 E8 537 Parts 540 F4 508 8 7 6 5 4 3 2 1 TO FCB-J2-2 703A 547 F3 (2A-SB) 517 PREVIOUSLY "44A6625" FCB (1A-SB) 44A7106/1 531 Siemens Airfield Solutions 571 533 LINE E7 534 534 E6 E5 240VDC E3 E4 AC INPUT J1 PROG. 505 506 507 504 904 Parts 537 570 529 509 528 532 543 (LINE) P1 533 PS5 (44A7107/1) 10 9 8 7 6 5 4 3 2 1 562 560 561 542 D1 J1 8 76 5 4 3 2 1 538 570 TO PS1-J1-1 (N) Q1 J3 531 Operation (BOTTOM SIDE) INSTALL JUMPER FOR "NON-CURRENT SENSE" OPTION 559 Disclaimer Figure 22: 96A0381 Rev. L 11/26/12 G/Y TERM. BLK. REV LEVEL ECO NUMBER REVISION DESCRIPTION DATE: ADB ADB Airfield Solutions 977 Gahanna Parkway, Columbus, Ohio 43230 Telephone: 614-861-1304, Fax: 614-864-2069 DRAWING TITLE: ADDED L-849A PRI. SW WIRING ASSOCIATED DRAWINGS: FOR "SECONDARY" UNIT, SEE RES. MOD. BE APPROVED BY: BE 24AUG07 DRAWN BY REV DATE DRAWN BY: DRAWN DATE: BE 24AUG07 Information contained on this drawing is to be used expressly in accord with purpose for which it was submitted. Any disclosure of this information is strictly prohibited except as ADB Airfield Solutions, Inc. may otherwise agree in writing. Copyright 2007 ADB Airfield Solutions. L-849A/E (CURRENT) LED FLASHER CTRL BOX INTERNAL WIRING DIAGRAM (PRI. & SEC.; W/MONITORING) SCALE: N/A SHEET NUMBER: DRAWING NUMBER: 1 OF 1 REV. 43A3319/INT/C I © 2012 ADB Airfield Solutions All Rights Reserved 96A0381 Rev. L 11/26/12 L-849 A/E Runway End Identifier Lights Typical Installation Details Disclaimer Figure 23: L-849 Voltage/Current, Style A and E Schematics CAUTION: THIS DRAWING IS ONLY INTENDED FOR USE AS GENERAL AIRFIELD SYSTEM DESIGN GUIDANCE. THE DESIGNER MUST VERIFY DESIGN WITH LOCAL CODES AND VARYING CHARACTERISTICS FOR EACH UNIQUE AIRFIELD APPLICATION. PRIMARY REFERENCE DOCUMENTATION: EXTERNAL WIRING VOLTAGE, 43A3320/V EXTERNAL WIRING CURRENT, 43A3320/C SECONDARY 20.00" [508.0mm] Table of Contents 8.80" [223.5mm] 16.00" [406.4mm] Safety 18.11" [460.0mm] SEE NOTE-1 SEE NOTE-4 L-867 BASE CAN (SEE NOTE 5) 8.00" [203.2mm] SEE WIRING DETAILS ON DRAWING 43A3319/EXT/C OR 43A3319/EXT/V Installation Introduction Schematics L-867 BASE CAN (SEE NOTE 5) Operation 4.68" [119.0mm] NOTES: 8 in. (203.2 mm) RUNWAY CENTERLINE 6 in. (152.4 mm) 1. OPTIONAL BASE FLANGE SHOWN FOR REFERENCE ONLY. Parts 2. USE 2 INCH RGS FEMALE COUPLING IF BASE FLANGE NOT USED. 3. 2 INCH ELBOW FOR EXTERNAL WIRES. 40 FEET +35' / -0' 40 FEET+35'/-0' SEE NOTE-2 4. THE OVERALL HEIGHT OF THE OPTICAL ASSEMBLY SHALL NOT EXCEED 34 INCHES. 5. BASE CANS NEEDED ONLY ON SERIES CIRCUIT POWERED REIL TO HOUSE ISOLATION TRANSFORMER. SEE DRAWING 43A3320/C FOR WIRING DETAILS. Parts 6 in. (152.4 mm) 12 in. (304.8 mm) 6. ADB AIRFIELD SOLUTIONS LED L-849A/E REIL/XXXXXXXX. RUNWAY THRESHOLD CONTROLLED COPY 24 in. or 6" below frost line (609.6) THRESHOLD LIGHTS SEE NOTE-3 BEAM AXIS BEAM AXIS 15° 15° © 2012 ADB Airfield Solutions All Rights Reserved INITIAL & DATE: REIL REIL TYPICAL REIL LAYOUT 20 in. (508.0 mm) E 2253 D 2253 C - B 3228 A REV LEVEL ---ECO NUMBER ASSOCIATED DRAWINGS: CABINET MOUNTING Schematics Unauthorized duplication of this document in whole or part is prohibited. Initialed in RED ink below indicates authorized copy. REPAIR EXTERNAL WIRING NOTE JEG 17MAY11 SEE EC JEG 16MAY11 UPDATE LOGO PRODUCTION RELEASE REVISION DESCRIPTION - - JLC 26APR11 JEG 22OCT07 DRAWN BY DRAWN BY: DRAWN DATE: JIM GAFFNEY 22OCT07 ADB Airfield Solutions 977 Gahanna Parkway, Columbus, Ohio 43230 Telephone: 614-861-1304, Fax: 614-864-2069 DRAWING TITLE: L-849 A/E RUNWAY END IDENTIFIER LIGHTS TYPICAL INSTALLATION DETAILS REV DATE All information contained herein, including illustrations, specifications, and dimensions, is believed to be reliable as of the date of this publication, but is subject to change without notice. Siemens reserves the right to make changes and improvements to its products and assumes no responsibility for these modifications. Any disclosure of this information is strictly prohibited except as ADB Airfield Solutions, Inc. may otherwise agree to in writing. Copyright © 2007 ADB Airfield Solutions, Inc. SHEET NUMBER: N/A DRAWING NUMBER: 117A0044 1 OF 1 REV. E 35 L-849 Voltage/Current, Style A and E Schematics 96A0381 Rev. L 11/26/12 Disclaimer Table of Contents Safety Introduction Installation Schematics Operation Parts Parts Schematics 36 © 2012 ADB Airfield Solutions All Rights Reserved L-849 Voltage/Current, Style A and E User Manual Registered office: France ADB Airfield Solutions LLC Phone: +33 (1) 4922 9250 ADB Fax: +33 (1) 4922 9255 Unit 44, Business Innovation Centre 977 Gahanna Parkway Binley Business Park Columbus, OH 43230 ADB Airfield Solutions GmbH & Co. KG Harry Weston Road USA Von-der-Tannstr. 31 Coventry, CV3 2TX Phone: +1 (614) 8611 304 90439 Nürnberg United kingdom Fax: +1 (614) 8642 069 Germany Phone: +44 (0)1455 883130 Phone: +49 (911) 9239 1287 Fax: +44 (0)1455 883179 Fax:+49 (911) 2852 582 Other addresses: ADB ADB N.V. Airfield Solutions ADB Airfield Solutions Ltd. Asia Pacific Regional HQ Leuvensesteenweg 585 5500 North Service Road, Suite 1108 Unit C-9.3.1, Level 9, Block C B-1930 Zaventem Burlington, Ontario L7L 6W6 Mines Waterfront Business Park Belgium Canada No. 3, Jalan Tasik Phone: +32 (2) 722 17 11 Phone: +1 (905) 331 6887 The Mines Resort City Fax: +32 (2) 722 17 64 Fax: +1 (905) 331 9389 43300 Seri Kembangan Selangor info.adb@adb-air.com Malaysia www.adb-air.com ADB Airfield Technologies Ltd. Phone: +603 8941 4868 01A Unit, 9F, LSH Plaza Fax: +603 8942 4869 8, Wangjing Jie Chaoyang District Beijing 100102 ADB Airfield Solutions Netherlands P.R. China Prinses Beatrixlaan 614 Phone: +86 10 8476 0106 Office D3.14 Fax: +86 10 8476 0090 2595 BM Den Haag The Netherlands ADB N.V. Phone: +31 (0)70 304 3611 Dubai Silicon Oasis Fax: +31 (0)70 333 8094 Wing D - Office D-309 P.O. Box 341218 ADB Airfield Solutions, Ltd. United Arab Emirates 2nd Floor, 3 Rivonia Village Phone: + 971 4372 4970 Cnr Mutual Road and Rivonia Boulevard Fax: + 971 4372 4975 South Rivonia 2128 ADB N.V./S.A. South Africa 39/47 Boulevard Ornano Phone: +27 (11)234 6768 93200 Saint-Denis Fax: +27 (11)234 6739 ADB Airfield Solutions USA 977 Gahanna Pkwy Columbus, Ohio 43230 USA Telephone: (+1 614-861-1304) Fax: +1 614-864-2069 www.adb-airfieldsolutions.com The information contained in this document is subject to change without notice. ADB reserves the right to make changes and improvements to its products and assumes no responsibility for making these modifications on any equipment previously sold. 96A0381 © 2012 ADB Airfield Solutions All Rights Reserved Document Date (12/2010)