Time Delay Relays Specially Time Delay Relays • CN Series Specially Time Delay Relays • SFR Serie Amplifier Relays, Switching Amplifier • SBV Amplifier Blinker • CPF Pulse Shaper • CCX Preset Counters This edition replaces all previous issues. Availability, errors and specification subject to change without notice. Industrial Time Delay Relays DIN CNS, CN CN 135 CNS-4 Industrial Time Delay Relays Cascade Relay Specially Time Delay Relays CN135 with 2 change-over contacts. CNS-4 with 4 independent outputs. • • • • • 2 functions • connections for external potentiometer 1M • 4 outputs • detachable terminals • seismic approved according IEE 323 and IEE 344 E ON cascades ON /OFF cascades 4 outputs detachable terminals E4 E4 Triggering Time range 0.1s-30 min Partial range s, min MAX Triggering Y1 Y2 t t t t 6 A 250 V A Y1 Y2 EA 4 A1 A2 B1 A2 B1 A1 A2 B1 A1 A2 B1 A1 A2 B1 A1 S S + + AC 50/60Hz UC AC/DC Ordering no. S + R1 R2 R3 + 15 18 25 28 35 38 45 48 S A R1 R2 R3 R4 0.1s-30 min On delay Off delay R4 S E On delay EA 4 Function (page ✹) t t t t 8 A 250 V A A1 15 25 S t t t t s, min R1 R2 R3 R4 R Y1 Y2 B1 R 16 18 26 28 Z1 Z2 A2 EXT POT AC 220-240 V ATX AC 220-240 V ATX AC110-120 V ANP AC110-120 V ANP UC 24-48 V UFK UC 24-48 V UFK CNS-4 / .... V CN 135 / .... V EXT POT 1M 3 2 1 max. 50m Z1 Z2 CN135 4 5 6 7 3 8 9 2 1 Ordering example Cascade Relay CNS-4/ ATX 10 Built-in potentiometer SP-01/1M (page ✹) Universal Timer Module CU CU23 • the time module for industrial application • 5 functions • t -stop • PNP/NPN output Time range Partial range x1 1 x6 1 x30 1 A K N Function (page ✹) 0.01s-300 min Partial range s, min MAX Triggering Series resistor Rv W Time range E 0,05- 30 m 1- 300 min 0,05-1s 0,3 - 6s 1,5-30s 0,05-1min 0,3 - 6min 1,5-30min 1- 10min 6-60min 30-300min 15 14 14 15 100K 10-28V A min s 5 17 18 19 20 + K + PNP 1M 1M 6 7 8 9 10 N A 8 E 9 K 10 1 N 10% DC12-24 V Ordering no. CU23 / .... V – NPN R 11 12 - 100K 560 nF 1M Built-in potentiometer (page ✹) SP-01/100k SP-01/1M 5 6 7 3 R 13 8 9 2 1 10 14 Rt 2 3 4 15 t x1 x6 x30 – S 4 + 6 7 6 7 8 9 10 W t 6 7 8 9 10 CU23 6 7 8 9 10 DC 0,05- 30 s 0,01-0,1s 0,06-0,6s 0,3-3s Wiring (view from the back) S + 0,01- 3 s 120 mA 24 VD 6 7 8 9 10 10 11 5 19 Adjustable resistor Rt Programming S 17 19 6K8 Extender capacitor Ct + 10 11 5 2 3 4 E Triggering min sec 18 STOP E Example for external wiring Universal Timer Module for Print Mounting 150 mA with soldering pins for printed circuit mounting. Ct 120 mA Universal Timer Module Time stop ( t - STOP) = the elapsing time is interrupted Ordering example Timer module CU23/DC12-24V This edition replaces all previous issues. Availability, errors and specification subject to change without notice. Amplifier Relays 11 SFR SFR1 SFR2 Amplifier Relay Amplifier Relay Amplifier Relay Supply unit with integrated switching amplifier for 3-wire PNP sensors, NAMUR as per DIN 19234 as well as for contact triggering also with external power supply. The input wiring is specifically suitable for long feed wires. • switching amplifier for: - PNP 3 wire sensors - NAMUR sensors • potential-free contact • integrated sensor supply voltage 24V • The input wiring is specifically suitable for long connection lines • switching amplifier for: - PNP 3 wire sensors - NAMUR sensors • potential-free contact • integrated sensor supply voltage 14V • The input wiring is specifically suitable for long connection lines 5 A 250 V A 6 A 24 V U MAX Diagram Connection with socket C11A 9 8 7 5 3 4 9 8 7 5 3 4 34 32 24 22 14 12 34 32 24 22 14 12 R A2 31 10 11 R 21 11 A1 A2 31 6 1 2 21 11 A1 10 11 6 1 2 + Output supply DC output supply Output voltage Output current max. Triggering + + + DC 22...25V 100mA 5 6 7 output active output inactive output inactive 5 6 7 DC 14V 4mA 5 6 7 output active output inactive output inactive 5 6 7 NAMUR sensor Not damped Damped Wire break + + PNP three-wire sensor 10-30VD + O 5 6 7 External power supply / contact Galvanic isolation AC 50/60 Hz 5 6 7 + + DC +18...+30V DC –30...+7,5V 7mA bei DC24V 100V 10ms/1Hz 18-30VD S S 5 6 7 >2kV (triggering to supply and output) >2kV (triggering to supply and output) UC AC / DC Ordering no. AC 220-240 V 5 6 7 DC +10...+30V DC –10...+5V 7mA bei DC24V 100V 10ms/1Hz 10-30VD S S 5 6 7 >2kV (triggering to supply and output) AC110-120 V UC 24V SFR2 / .... SFR1/ .... System socket C11A Figure: with plug-in neutral conductor connector C-A2 (standard delivery). 16 4 38x72cm On-signal Off-signal triggering current Parallel load energy + (M4) C-A2 Ordering example Amplifier relay SFR1/AC220-240V Socket C11A FOR PLUG-IN MODULES FS-23 4 20 92 9 5 6 7 Amplifier Relays 11 SBV K K 70 80 60 90 UB 10...45V IS 5...15 mA I RL max. 10 A SSV11 SBV11 Blinker and Aplifier Amplifier-Blinker Switching Amplifier Relay with solid state output specially suitable for frequent switching cycles. With solid state output. Adjustable electronic flasher for 60-90 pulses/min. Switching voltage 10-45V DC and switching loads up to 10A. The short circuit limiter and the overload proof design alows wear free switching of filament lamps in general but as well as all ohmic, inductive and capacitive loads. Triggering supply is indicated by LED. With solid state output. For applications in automation where high switching cycles and loads up to 10A at 10-45V DC are required. For example for solenoids, magnetic clutches and other ohmic inductive or capacitive loads. With built-in short circuit limiter and over-load protection circuit, this amplifier switches wear free and guarantees high service life. LED display for trigger signal. Function (page ✹) B Time range 60-90 I/min MAX 10 A 10 - 45 VD 10 A 10 - 45 VD Diagram S Connection with socket CS11 8 S Amplifier Blinker 7 6 5 4 32 24 21 22 12 8 7 6 5 4 32 24 21 22 12 S K K 34 A2 31 11 A1 14 9 10 11 1 2 3 34 A2 31 11 A1 14 9 10 11 1 2 3 + + DC 10% SBV11/ .... DC12-36 V DC12-36 V SSV11/ .... 38x72cm Ordering no. DC 24-48 V + Ordering example Amplifier relay SBV11/DC12-36V Socket CS11 This edition replaces all previous issues. Availability, errors and specification subject to change without notice. Pulse Shapers DIN CPF CPF11 CPF22 CPF Pulse Shapers Single Channel Pulse Shaper Double Channel Pulse Shaper with the timing functions K, L and A are specialist devices for the lengthening or the limitation of control pulses. In this fully electronic design with the facility for also con-necting NAMUR sensors they are the ideal interface modules in modern control systems. Always there where fast processes, high rotations, i.e. the briefest pulses, are to be evaluated, the costeffective solution is: CPF Pulse shapers. • Input reversible (E-E) • Input and output times separately settable • 3(6) functions to choose • Additional free wheel diode 1A • LED display for E and Q • Input/output galvanically isolated 4kV • Input and output times separately settable • 2 functions to choose • LED output display for each channel Function (page ✹) K L A K A Time range input pulse output pulse 1/ 5 ms 5 ÷600 ms input pulse + 15÷32VD NAMUR sensor Three-wire sensor + + E2 4kV E1 K CPF CPF O 150mA FD + 0,8A 10% Ordering no. + DC 24 V PNP 1O 10÷45VD RL DC 1E1 1E2 2E1 2E2 11K 5K6 4K7 PNP S PNP E1 2S 1S + E1 E2 3K3 + 50 / 200 ms 15÷32VD S 15…32V 19…28V + S NAMUR + + output pulse 0,5 / 2,5 ms 2O 2RL 1RL DC 24 V CPF11 / .... V CPF22 / .... V CPF11 TS 35 75 CPF22 Pulse shaper CPF11/DC24V 4,2 17,5 2,5 Ordering example 8 5 64 10 11 CCX Preset Counters CCX-350 CCX-550 Functions Preset Counters Preset Counters Preset Counters with display Electronic pre-select counter with 2 change-over contacts. Digital value display with LED function indication. Suitable for front panel mounting. Switching after the preset number of pulses are reached. Switching after the preset number of pulses are reached. • 7 digit LED display Triggering: • potential-free contact • NAMUR sensor • PNP U 1 n CE CK Q Q is active after reaching the preselected number of pulses. Q and C can be reset with the reset button. Triggering: • potential-free contact • NAMUR sensor • PNP CE CK CI U n 0 - 999 200Hz 200Hz 6 A 250 V A 6 A 250 V A R Q U 1 n 1 Diagram PNP t 6 7 6 7 6 7 6 NAMUR COUNT R RESET C 7 6 5 4 8 7 6 5 4 32 24 21 22 12 32 24 21 22 12 OUTPUT OUTPUT 34 A2 31 11 A1 14 34 A2 31 11 A1 14 UC AC/DC 9 10 11 1 2 3 AC220-240 V ATX AC220-240 V ATX AC110-120 V ANP AC110-120 V ANP UC 24-48 V UFK UC 24-48 V UFK CCX-350 / .... CCX-550 / .... 38x72cm Ordering no. ON OFF Q 9 10 11 1 2 3 Ordering example Counters CCX-350 Socket CS11 C Q R RESET 8 Q AC 50/60 Hz C n Q is active for t 75...125ms on the preselected pulse. The cycle starts again at the beginning. Q and C can be reset with the reset button. NAMUR COUNT 1 R CI Connection with socket CS11 7 C Q is active during the preselected number of pulses and can only be reactivated after a reset. Q and C can be reset with the reset button. 0 - 999 Count frequency PNP 1 CK CI Preselection MAX C R CE 1 Function 1 U = Voltage C = Count R = Reset Q = Output relays ! Kühn Controls AG Notes: You want more information about this product, please call us: tel: +49 (0)7082-940000 or send us a fax: +49 (0)7082-940001, or email: sales@kuehn-controls.de or visit our Website: www.kuehn-controls.de