RH-200 Passive Infrared (PIR) Multi-Way Wall Switch

advertisement
R E S I D E N T I A L WA L L S W I TC H S E N S O R S A N D T I M E S W I TC H E S
RH-200 Passive Infrared (PIR) Multi-Way Wall Switch
Vacancy Sensor
Lighted switch for visibility
in darkened rooms
Occupancy-based control plus
multi-way operation
Ideal for stairways, hallways,
large spaces and bathrooms
with multiple entrances
Adjustable time delays,
light level sensing
Compliant with
California Title 24-2005
PROJECT
LOCATION/TYPE
Product
Overview
Description
Multi-Way Operation (continued)
The RH-200 Multi-way Vacancy Sensor offers automatic lighting shutoff as well as multi-way control
for special applications in the home.
from the connected RH-200’s will automatically
turn the lights on. Lights will remain on as long as
any of the connected RH-200’s continue to detect
occupancy. Regardless of operating mode, an
occupant may manually turn the load OFF by
pressing the push-button. If the room becomes
vacant and lights are left on, the last RH-200 to
detect occupancy will dictate when the lights will
turn off after the predetermined time delay has
elapsed.
Operation
The RH-200 employs advanced PIR technology to
sense the difference between infrared energy from
a person in motion and the background space.
When set to operate in Manual-ON mode, the
factory setting, users must press the push-button
to turn lighting on. This setting may be changed to
utilize Automatic-ON operation when desired.
Multi-Way Operation
While providing secured and enhanced coverage,
two or more RH-200s connected together allow
true multi-way ON/OFF control. When connected in
Manual-ON mode, an occupant entering the controlled area must press the ON/OFF button of any
connected switch to turn the load ON. If operating
in Automatic-ON mode, any occupancy detection
Features
The RH-200 has the flexibility to work in a variety
of applications including hallways, stairways, bathrooms, living and dining rooms and other areas
with multiple entries. In addition, the RH-200 is the
only vacancy sensor that allows true multi-way
operation with automatic on/off control.
• Occupancy-based control plus multi-way
operation
• Works with most common residential lighting
types
• Two or more RH-200’s connected together
together will allow enhanced coverage of the
controlled space
• Relay-based switching
• Low-profile styling with uniform, color-matched
lens and device
• Choice of three decorator colors
• Lighted switch for visibility in darkened rooms
• Manual- or Automatic-ON operation
www.wattstopper.com
800.879.8585
Applications
• No leakage to load in OFF mode for safety
• Adjustable time delay from 15 seconds to 30
minutes
• Light level sensing prevents automatic ON of
lights when adequate daylight exists
• Replaces three-way or four-way switches when
used with other RH-200’s
• Dimensions: 2.8" x 4.8" x 1.5" (71.1mm x
121.9mm x 38.1mm)
• UL and CUL listed; five-year warranty
Controls
Wiring for 3-Way Operation
Hot
Neutral
Load
TOP
White
Neutral
Black
Traveler 1
Black
Yellow
Traveler 2
Yellow
Ground
Ground
MASTER RH-200
Lock Bar
Light
Level
INDOOR USE ONLY
AUXILIARY RH-200
Mode 15
1–Manual Min.
2–Auto-ON
06689r1
Mode but ton and
adjustment trimpots
15
Sec.
White
min
INDOOR USE ONLY
TOP
* Red
30
Min.
Red
TOP
max
Wiring Diagrams
& Controls
• Adjustable light level setting of 10 to 150 fc (100
to 1500 lux)
• 120 VAC, 60 Hz
• Coverage: 180°, 600 ft2 (56 m2)
• Operates incandescent, fluorescent, compact
fluorescent (CFL), magnetic low voltage (MLV),
electronic low voltage (ELV), and 1/6 hp loads
• Adjustable time delay of 15 seconds, or of five,
15 or 30 minutes
5
Min.
Time Delay
Slide down
ON/OFF
Button
INDOOR USE ONLY
* each RH-200 connected is capable of controlling one independent load wired to its own red wire. For advanced wiring
options contact Watt Stopper/Legrand’s technical support team.
Applications
RH-200 Bedroom, Jack & Jill Bathroom, and Stairway Applications
Stairway
Bedroom 2
Bathroom
RH
RH
RH
RH
RH RH
RH
RH
Key
- Surface mounted decorative
incandescent fixture
Bedroom 1
RH - Represents RH-200 Wall
Switch
- Represents connection
between sensors
Coverage
25'
(7.6m)
25'
(7.6m)
4.0'
(1.2m)
floor
12'
(3.7m)
Ordering
Information
Catalog No.
Color
Special Feature
Voltage
Load Requirement
Coverage
RH-200-W
White
Single Pole,
120 VAC, 60 Hz
0-600W incandescent,
180°, max. 600 ft2
RH-200-I
Ivory
3-way, 4-way,
fluorescent, CFL, MLV,
(56m2)
RH-200-LA
Light Almond
multi-way operation
ELV, 1/6 hp
RH-200-B
Black
Order ASP-121 for blank cover plate for 2-gang box; Order ASP-122 for cover plate for 2-gang box with switch option.
Pub. No. 22503
www.wattstopper.com
800.879.8585
R E S I D E N T I A L WA L L S W I TC H S E N S O R S A N D T I M E S W I TC H E S
Specifications
Download