Transportation Surge Protection

advertisement
Surge Protection
TM
For Business-Critical Continuity
Transportation Surge Protection
Product Catalog
Keeping Power Clean And Green
Power Protection To Keep Traffic
Flowing Smoothly … Think about the challenge of
navigating rush-hour traffic, even on a good day. Then imagine
the havoc and congestion that power surges, spikes, noise and
transients can create, turning your commute into a nightmare.
When traffic signaling equipment goes down, it creates a ripple
effect. Even when you’re up and running again, the unfortunate
effects can resonate for hours after an occurrence.
For more than 35 years, Edco™ surge protection products have
been protecting equipment against these potentially catastrophic
occurrences.
Whether it’s highway lighting, traffic signals, controller cabinets,
cameras, high speed/commuter rail, dynamic message signs,
toll roads, weigh stations and red light/speed enforcement or
sophisticated intelligent systems, rest assured that Emerson
Network Power Edco products deliver the mission-critical
protection you need to keep all your sensitive equipment
operating as expected.
Emerson Network Power Surge Protection manufactures power
quality solutions in the following categories:
AC Power Surge Protection
• Limit high-voltage spikes to an acceptable level
Filtering/Line Conditioning
• Protect against low-energy transients and high
frequency noise
Data/Signal Line Protection
• Guard sensitive instrumentation against what we refer to as
“backdoor” transients and noise
Why put your equipment at risk? Turn to Emerson Network
Power Surge Protection products for peace of mind. We provide
solutions for all your application needs and the foundation for
Business-Critical Continuity™.
We are committed to providing quality products, competitive
pricing and reliable customer care. If you have any product
application or pricing questions, please call us at 800-288-6169.
We look forward to hearing from you. We’re here to help!
Products
Table of Contents
Page #
AC Power — SerieS ConneCted
Edco™ ACP-340 — 120 VAC — Single Phase
Edco™ ACP-340LED/540LED —120 VAC — Single Phase/240 VAC — Single Phase
Edco™ SHA-1210 —120 VAC — Single Phase
Edco™ SHP Series —120 VAC — Single Phase/240 VAC — Single Phase Filter, 120 VAC or 240 VAC
Edco™ SHA-1250 — 120 VAC — Single Phase — Modular
Edco™ HSP Series — 120 VAC Heavy Duty 120 Volt AC
Islatrol™ — SP-6TVN — Plug-in Surge Protection/Active Tracking™ Filter
Islatrol™ — RM Series — 120 VAC Rackmount
Edco™ SHA-1230FS — 120 VAC — Single Phase — 30A FingerSafe
Edco™ SHA-1260 — 120 VAC — Single Phase — 60A
Islatrol™ INXT120NL000-1 — AC Power Line Filter
2
3
4
5
6
7
8
9
10
11
12
AC Power — PArAllel ConneCted
PowerSure™ EMC-240B — 120/240 VAC Heavy Duty (Parallel)
PowerSure™ FAS-120AC — Medium Duty 120 VAC — Single Phase
Edco™ SPA-300 — Medium Duty 120 VAC — Single Phase
Edco™ SPA-100T — AC Service Protection
Edco™ SHA-1201 — 120 VAC — Single Phase
13
14
15
16
17
low VoltAge dC Power
Edco™ FAS-1 and FAS-2 Series — One- and Two-Pair Signal Line Protection
Edco™ PHC Series — Two-Pair Signaling Circuit Protector (Modular)
18
19
inPut FileS/looP deteCtion
Edco™ SRA-6LC Series — Vehicle Loop Detection
Edco™ SRA16C-1 — Vehicle Loop Detection
Edco™ MRA-6LC-6 — Vehicle Loop Detection Protector
20
21
21
outPut FileS
Edco™ SPA-303 — 120 VAC Load Relay
Edco™ MPA-303 Series — Modular Output File Protector
22
22
CommuniCAtion lineS
Edco™ PC642 Series — Zone/Loop/Data
Edco™ SRA64 Series — Single Pair Data/Signal
Edco™ SPA-60B — 120 VAC Interconnect Signal
23
24
25
Video
Edco™ CX Series — CCTV Applications/Coax
Edco™ HVCP-48 — Video Control Power Protection
26
27
modem
Edco™ FAS-TEL-DOT — RJ Connection Telephone Protection for Traffic Cabinets
28
dAtA/SignAl line
Edco™ RJA-RJD Series — RJ-45 Telephone/Data
Edco™ SRS-BIU-15 — NEMA TS-2 Port 1 Protector
29
30
HigHwAy ligHting
Edco™ SHA Series — Highway Lighting Protection
Edco™ SHAS Series — Highway Lighting Protection
31
32
AC Power — Series Connected
edco™ ACP-340
120 VAC — Single Phase
The Edco ACP-340 filtering surge protector absorbs power line noise and
switching transients that other suppressors and RFI filters pass through. The
Edco ACP-340 can replace the RFI filter when high attenuation of noise above
25 MHz is not required.
If random time-base, memory loss, or other problems are affecting some of
your intersections, this state-of-the-art protector can be of great benefit when
properly installed.
Features
■ Multi-stage hybrid design
■ Incorporates series choke
■ Industry-leading noise filtering
■ 5 year warranty
■ Nanosecond response time
general technical Specifications
installation
Part Number
Edco ACP-340
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
10A
Peak Surge Current
32.5 kA/Mode, 39 kA/Phase
Operating Frequency
120 / VAC
Input
47–63 Hz
EMI Attenuation
60 dB typ
SPD Technology
MOVs w/L-C Filter
Modes of Protection
L-N, L-G, N-G
Status Indication
NA
Connection Type
1/4-20 Stainless Steel Stud
Operating Temperature
Main Line
Edco
ACP-340
Main
Neutral
Gnd
Earth
Site Variable
(option)
Earth
Line Out
Neutral Out
Protected Power
Source
(to controller and other
sensitive electronics)
-40°C to +70°C
Dimensions (Inches)
2.375H x 3.125W x 7.125L
Weight
1 lb 13.5 oz
Caution:
1. This product could become excessively hot and rupture in the rare event of
power line conditions or surge that exceed its rated operating specification.
Appropriate precautions should be exercised.
mounting
2. High voltages are present on electrical termination. Unit should be serviced by
qualified personnel only.
Hole (6 places)
3/16" Dia.
1.28"
Plate
3.125"
1.28"
6.65"
7.125"
2
Cabinet Power AC
Hot Bus
AC Power — Series Connected
edco™ ACP-340led/540led
120 VAC — Single Phase/240 VAC — Single Phase
The Edco ACP-340LED is an upgrade to the popular Edco ACP-340, adding a failure
indicator as well as remote sensing circuitry. In addition, this unit offers much
better lightning protection than the standard Edco ACP-340.
The Edco ACP-340LED/540LED filtering surge protectors absorb power line noise
and switching transients that other suppressors and RFI filters pass through.
They can replace the RFI filter when high attenuation of noise above 25 MHz is
not required.
The Edco ACP-340LED/540LED utilize Thermally-protected Metal Oxide
Varistors (TMOVs) with an integrated thermally activated element designed
to open in the event of overheating due to the abnormal over-voltage, limited
current conditions.
Features
oPtion
din rAil Kit AVAilABle
order PArt # 11604Kit
■ 50 kA/Mode & 100 kA/phase surge
current protection
■ Power On and failure LED
■ Thermally-protected Metal Oxide
Varistors (TMOVs)
■ 5 year warranty
installation
general technical Specifications
Part Number
■ Remote sensing circuitry
Edco ACP-340LED/540LED
Maximum Operating Voltage
120 VAC/240 VAC
Clamping Voltage
395 VAC/775 VAC
Operating Current
Cabinet Power AC
Hot Bus
15A
Peak Surge Current
50 kA/Mode, 100 kA/Phase
Operating Frequency
47–63 Hz
EMI Attenuation
60 dB typ
SPD Technology
MOVs w/L-C Filter
Modes of Protection
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
1/4-20 Stainless Steel Stud
Operating Temperature
120 / VAC
Input
Main Line
Main
Neutral
Edco
ACP-LED Series
Neutral Out
Gnd
Earth
Site Variable
(option)
Earth
Line Out
NC C NO
To Remote
Indication
If Needed
Protected Power
Source
(to controller and other
sensitive electronics)
-40°C to +85°C
Dimensions (Inches)
1.875H x 3.25W x 5.75L
Weight
1 lb
Caution:
1. This product could become excessively hot and rupture in the rare event of
power line conditions or surge that exceed its rated operating specification.
Appropriate precautions should be exercised.
mounting
Hole (4 places)
3/16" Dia.
Plate
2. High voltages are present on electrical termination. Unit should be serviced by
qualified personnel only.
2.25"
3.25"
5.25"
5.75"
3
AC Power — Series Connected
edco™ SHA-1210
120 VAC — Single Phase
The Edco SHA-1210 filtering surge protector absorbs power line noise and
switching transients that other suppressors and RFI filters pass through.
The Edco SHA-1210 can replace the RFI filter when high attenuation of noise
above 25 MHz is not required.
If random time-base, memory loss, or other problems are affecting some
of your intersections, this state-of-the-art protector can be of great benefit
when properly installed.
Features
■ Multi-stage hybrid design
■ Incorporates series choke
■ 60 dB maximum noise filtering
■ 5 year warranty
■ Nanosecond response time
installation
general technical Specifications
Part Number
Edco SHA-1210
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
10A
120 VAC
Input
Earth
32.5 kA/Mode, 39 kA/Phase, 65 kA/Total
47–63 Hz
EMI Attenuation
60 dB typ
SPD Technology
MOVs w/L-C Filter
L-N, L-G, N-G
Status Indication
NA
Connection Type
1/4-20 Stainless Steel Stud
Operating Temperature
Edco
SHA-1210
Main
Operating Frequency
Modes of Protection
CB
Neutral Out
AC Out
AC In
Protected Power
Source
(to controller and other
sensitive electronics)
Site Variable
(option)
Earth
AC Hot Buss
Cabinet Power
-40°C to +70°C
Dimensions (Inches)
2.375H x 3.125W x 7.125L
Weight
2 lbs
Caution:
1. This product could become excessively hot and rupture in the rare
event of power line conditions or surge that exceed its rated operating
specification. Appropriate precautions should be exercised.
2. High voltages are present on electrical termination. Unit should be
serviced by qualified personnel only.
mounting
Hole (6 places)
3/16" Dia.
1.28"
Plate
3.125"
1.28"
6.65"
7.125"
4
Neutral
Buss
Equipment
Side
Peak Surge Current
Main
Neutral
AC Power — Series Connected
edco™ SHP Series
Single Phase Filter, 120 VAC or 240 VAC
The Edco SHP Series hybrid design exhibits performance levels unattainable with
simple “shunt type” protectors. The two active clamp stages, large inductor
and shunt capacitance effectively halt high rate-of-rise surge waveforms, thus
preventing initial voltage overshoot.
Flexibility of installation is another design feature of the Edco SHP Series. The
protector first and second stages are electrically separate (line side) for use in
jurisdictions that require a line filter between stages.
In addition, the first stage provides protection from MAIN NEUTRAL to GND as
well as MAIN LINE to GND. This is an often overlooked feature which becomes
significant in locales where NEUTRAL must be kept separate from earth ground
inside the cabinet.
Features
■ Multi-stage hybrid design
■ I ncorporates series choke
■ Nanosecond response time
■ 5 year warranty
■ Blocks high energy surges
installation
general technical Specifications
Part Number
Edco SHP300-10/SHP400-10
Maximum Operating Voltage
120 VAC/240 VAC
Clamping Voltage
395 VAC/650 VAC
Operating Current
10A
Peak Surge Current
CB
58.5 kA (8 x 20 µs)
Cabinet Power
AC Hot
Line Filter
(optional)
Connection If Line
Filter Is NOT Used
Main Line
Line In
120 VAC
Input
Operating Frequency
47–63 Hz
EMI Attenuation
70 dB typ
SPD Technology
MOVs w/L-C Filter
Modes of Protection
Main
Neutral
NA
Connection Type
1/4-20 & 10-32 Stainless Steel Stud
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1.8H x 2.875W x 5.3L
Weight
1 lb
mounting
Line Out
Neutral
Out
}
Neutral Buss
L-N, L-G, N-G
Status Indication
Edco
SHP Series
Earth Ground
Earth Ground
Protected Power
Service (to controller and
other sensitive electronics)
Caution:
1. This product could become excessively hot and rupture in the rare
event of power line conditions or surge that exceed its rated operating
specification. Appropriate precautions should be exercised.
2. High voltages are present on electrical termination. Unit should be
serviced by qualified personnel only.
3/16" Dia.
(6 places)
1.17"
2.875"
1.17"
4.85"
5.30"
5
AC Power — Series Connected
edco™ SHA-1250
120 VAC — Single Phase — Modular
The Edco SHA-1250 is an upgraded version of the Edco SHA-1210. The Edco
SHA-1250 also incorporates two LEDs for failure indication in a modular package
(Utilizes 12 pin Beau connector). The hardwire terminal base (Edco SHA-1250BASE-A, ordered separately) accommodates all wiring and the protection module
is designed for easy replacement. The footprint of the Edco SHA-1250-BASE-A is
the same as the Edco ACP-340 and Edco SHA-1210. This makes retrofitting older
cabinets easy because internal wire lengths do not have to be adjusted.
The Edco SHA-1250 offers remote sensing circuitry output that is a dry relay
contact closure suitable to interface with a modem or computer port for polling
remotely. With this feature, a central computer could detect a failed Edco
SHA-1250 at the intersection.
SHA-1250 and SHA-1250-BASe-A (Sold Separately)
The Edco SHA-1250 provides excellent noise suppression over a large frequency
range. Typical noise attenuation is 10 dB @ 28 KHz, 54 dB @ 100 KHz and
50 dB @ 1 MHz.
Features
■ Plug-in module
■ Remote-sensing circuitry
■ LED indication
■ Patented technology
■ Filtering
■ 5 year warranty
general technical Specifications
Part Number
Edco SHA-1250
Maximum Operating Voltage
120 VAC
Clamping Voltage
340 VAC
Operating Current
15A
Peak Surge Current
1.28"
Plate
3.125"
1.28"
47–63 Hz
EMI Attenuation
50 dB typ
SPD Technology
MOVs w/L-C Filter
Modes of Protection
6.65"
7.125"
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
1/4-20 SS Stud Base, Plug-in Module Operating
Operating Temperature
Dimensions (Inches, Module + Base)
Weight
(Module + Base)
Hole (6 places)
3/16" Dia.
26 kA/Mode, 32.5 kA/Phase, 45.5 kA/Total
Operating Frequency
6
mounting
-40°C to +85°C
3.5H x 3.125W x 7.125L
1 lb 11.5 oz
Caution:
1. This product could become excessively hot and rupture in
the rare event of power line conditions or surge that exceed its
rated operating specification. Appropriate precautions should
be exercised.
2. High voltages are present on electrical termination. Unit should be
serviced by qualified personnel only.
AC Power — Series Connected
edco™ HSP Series
120 VAC Heavy Duty 120 Volt AC
The Edco HSP Series is an advanced three-stage hybrid, solid state powerline protector. Features such as noise filtering, common mode and normal
mode suppression, nanosecond reaction time, power line tracking, and
compression screw terminations make the Edco HSP Series an excellent
choice in commercial and industrial applications.
edCo HSP121Bt-1ru
The Edco HSP Series offers a replaceable fuse designed to remove the load
(protected equipment) from the line if the unit is either overloaded or
the internal protection fails. This feature prevents surges from entering
equipment through a failed protector not noticed by the user.
Features
■ Fast response time
■ Three-stage hybrid design
■ Failure indicator
■ Replaceable fuse
■ Power line tracking
■ 1/2" or 3/4" knockouts for nipple
conduit connectors (HSP121A)
■ Filtering
■ Polycarbonite NEMA 4X enclosure
(HSP121A)
edCo HSP121A
general technical Specifications
Maximum Operating Voltage
120 VAC
Clamping Voltage
325 VAC
Operating Current
15A
I-Nominal (In)
3 kA
Total Peak Surge Current
dimensions
Mounting – HSP121BT-1RU
Holes 3/16" Dia.
39 kA (8 x 20 µs)
Operating Frequency
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
SPD Technology
■ 5 year warranty
> 40 dB
Light On – Normal
Light Off – Requires Service
Metal Oxide Varistors (MOVs)
w/ L-C Filter
Modes Of Protection
Line-to-Neutral,
Line-to-Ground,
Neutral-to-Ground
Status Indication
Power On & MOVs functional
Connection Type
3 Position, 20A Terminal Block
w/Compression Screws
Terminals Accept Up To 14 AWG
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
Mounting – HSP121A
Holes 3/16" Dia.
3/4" Conduit Fitting
3/4" Conduit Fitting
GND
1/2" Conduit Fitting
GND
N
N
AC
AC
1/2" Conduit Fitting
HSP121BT-1RU 1.8H x 2.9W x 5.3L
HSP-121A 2.95H x 4.95W x 3L
Weight
Certifications
10 oz
HSP121BT-1RU
ANSI/UL1449 Third Edition, Type 4
HSP121A
ANSI/UL1449 Third Edition, Type 2
7
AC Power — Series Connected
islatrol™ SP-6tVn
Plug-in Surge Protection/Active Tracking™ Filter
The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device
that plugs into a standard duplex receptacle. It features uniquely designed
repositionable outlets and protects against damaging power disturbances
traveling through your wiring into your electrical outlets.
Features
■ Plugs into standard 120V, 15A
electrical outlet
■ Perfect for tight spaces, behind furniture
and appliances
■ Total peak surge current capacity of 39 kA
■ Intelligent monitoring against improper
wiring/grounding
■ Cables for telephone, video, and
data connectors included
rePoSitionABle outletS
■ Repositionable outlets rotate to
accommodate available space
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ 5 year warranty
general technical Specifications
AnSi/ieee C62.41 Cat A ringwave (6 kV, 200A, 100 kHz)
AC Power Protection
Nominal Operating Voltage
120 VAC, Single Phase
Operating Voltage Range
120 VAC +/- 10%
Operating Frequency Range
265V
Common Mode
290V
47–63 Hz
Rated Output
15A
ANSI/IEEE C62.41 Category
Category A & B
Connection Type
(6) 5-15R Receptacles and
5-15P Plug
Phase Configuration
2 Wire + Gnd
Size
7.5 x 4.75 x 1.75 (Inches)
Enclosure
High Impact Plastic
Weight
AnSi/ieee C62.41 Cat B ringwave (6 kV, 500A, 100 kHz)
Normal Mode
275V
Common Mode
290V
Frequency response
Normal Mode
Common Mode
L – N, L – G, N – G
Indication of Suppression Status
< .5 ns Normal Mode
ANSI/UL 1449 Third Edition Type 3
Warranty
Video 1 & 2
Phone
network
Connection Type
Type “F”
Type RJ-11
Type RJ-45
Cables Provided
6 (2x) Type “F”
6' Ends
RJ-11 Male
6' Ends
RJ-45 Male
Ends
5 kA
(8 x 20 µs)
2 kA
(10 x 1000 µs)
3 kA
(8 x 20 µs)
5 Year
Peak Surge Current
maximum Continuous operating Voltage (mCoV)
130 VAC
Capacitance
Protection Level
Clamping Voltage (DC)
Peak Surge Current (8 x 20 ms)
8
40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz
low Voltage Protection
Status Indicator
Response Time
Line To Neutral
60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz
2.0 lbs (0.9 kgs)
Modes Of Protection
Certification
Normal Mode
Line To Neutral
13 kA
Line To Ground
13 kA
Neutral To Ground
13 kA
Total
39 kA
Attenuation
<12 pf
<50 pf
<70 pf
L-G
T-R, T-G, R-G
L-G (8 Lines)
145 V
270-350 V
30 V
1 dB @ 2 Ghz
N/A
N/A
AC Power — Series Connected
islatrol™ — rm Series
120 VAC Rackmount
This line of AC surge protectors is ideal for protecting the power feeding
valuable rack equipment. All models provide ten protected outlets on
the back and two protected convenience outlets on the front. This series
provides 40,000 Amps of surge protection and up to 60 dB of highfrequency noise filtering. Status LEDs indicate the correct power is coming
to the unit, whether the unit is properly grounded and whether the surge
components are still intact. Units are available with an optional digital
meter, mounted on the front of the unit, that will monitor the voltage,
current and power of the protected equipment.
model Shown: rm-115-10 rm
Features
■ 40 kA surge protection
■ Digital meter
■ 60 dB max. noise filtering
■ Optional twist lock plug
■ 15 A & 20 A models available
■ 1 year warranty
■ Power, ground and surge status indicators
general technical Specifications
Part number
Voltage
Amperage
Plug (nemA)
receptacles (nemA)
digital meter
locking Plug
RM-115-10RM
120 V
15 A
5-15P
5-15R
Yes
No
RM-120-10RM
120 V
20 A
5-20P
5-20R
Yes
No
rackmount AC Power Protection
Rated Voltage
120 V
Rated Current
15 A & 20 A
Peak Surge Current
Response Time
EMI/RFI Filtering
LED Indicators
Digital Meter
Input Power
15 A Models
20 A Models
20 kA/Mode, 40 kA/Phase
<5 ns
60 dB Max.
Green-Power On
Green-Ground OK
Green-Surge Circuit OK
Voltage Amps, Watts, VA, Hz, PF,
Kwh, and Clock
Output Receptacles
15 A Models
20 A Models
Thermal Protection
Over-current Protection
Front- (2) NEMA 5-15R
Back- (10) NEMA 5-15R
Front- (2) NEMA 5-20R
Back- (10) NEMA 5-20R
Thermal Protected MOVs
Circuit
Dimensions
1.75"H x 19"W x 2.0"D (1U)
Certification
ANSI/UL1449 Third Edition, Type 3
Warranty
1 Year
SJT 14/3C Power Cord (15 ft)
with NEMA 5-15P Plug
SJT 12/3C Power Cord (15 ft)
with NEMA 5-20P Plug
NEMA L5-20P Plug- Optional
9
AC Power — Series Connected
edco™ SHA-1230FS
120 VAC — Single Phase — 30A FingerSafe
The Edco SHA-1230FS is a FingerSafe 120 VAC Single Phase 2W+G, 30A surge
suppressor/filter designed to shunt electrical type transients affecting the
electrical distribution inside a traffic cabinet.
The Edco SHA-1230FS offers 50 kA per mode and 100 kA per phase of surge
current protection.
The Edco SHA-1230FS utilizes Thermally-protected Metal Oxide Varistors
(TMOVs) with an integrated thermally activated element designed to open
oPtionS:
din rAil Kit AVAilABle. order PArt # 11604Kit
unit AVAilABle witH Power on PluS FAilure led
And Form C relAy ContACtS (SHA-1230FSr)
in the event of overheating due to the abnormal over-voltage, limited
current conditions.
Features
■ 120 VAC, 30A service
■ Power On and Failure LED
■ FingerSafe connection
■ 50 kA/Mode and 100 kA/phase surge current protection
■ Thermally-protected Metal
Oxide Varistors (TMOVs)
■ Summary alarm contacts
general technical Specifications
Part Number
■ 5 year warranty
mounting
Edco SHA-1230FS
Maximum Operating Voltage
120 VAC
Clamping Voltage
400 VAC
Operating Current
Hole (4 places)
3/16" Dia.
30A
Peak Surge Current
50 kA/Mode, 100 kA/Phase, 150 kA Total
Operating Frequency
Plate
2.25"
3.25"
47–63 Hz
EMI Attenuation
40 dB Normal/30 dB Common Mode
SPD Technology
MOVs w/L-C Filter
Modes of Protection
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
Recessed Terminal Screws
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1.875H x 3.25W x 5.75L
Weight
12 oz
5.25"
5.75"
Caution:
1. This product could become excessively hot and rupture in the
rare event of power line conditions or surge that exceed its rated
operating specification. Appropriate precautions should be
exercised.
2. High voltages are present on electrical termination. Unit should be
serviced by qualified personnel only.
installation diagram
L
Line Input
From Source
N
GND
10
Line
Load
L
L
N
N
GND
GND
To Load or
Equipment
to Protect
AC Power — Series Connected
edco™ SHA-1260
120 VAC — Single Phase — 60A
The Edco SHA-1260 is a 120 VAC Single Phase 2W+G, 60A surge suppressor/filter
designed to shunt electrical type transients affecting the electrical distribution
inside a traffic cabinet.
The Edco SHA-1260 offers 50 kA per mode and 100 kA per phase of surge
current protection.
The Edco SHA-1260 utilizes Thermally-protected Metal Oxide Varistors (TMOVs)
with an integrated thermally-activated element designed to open in the event of
overheating due to the abnormal over-voltage, limited current conditions.
Features
■ 120 VAC, 60A service
■ Thermally-protected Metal Oxide Varistors (TMOVs)
■ Phosphor bronze stud for
substantial conductivity
■ 50 kA/mode and 100 kA/phase surge current protection
■ 5 year warranty
■ Power On and Failure LED
installation
general technical Specifications
Part Number
Edco SHA-1260
Maximum Operating Voltage
120 VAC
Clamping Voltage
400 VAC
Operating Current
60A
Peak Surge Current
50 kA/Mode, 100 kA/Phase, 150 kA/Total
Operating Frequency
47–63 Hz
EMI Attenuation
40 dB typ
SPD Technology
MOVs w/L-C Filter
Modes of Protection
L
Line Input
From Source
N
GND
Line
Load
L
L
N
N
GND
To Load or
Equipment
to Protect
GND
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
Phosphor Bronze 1/4-20 Stud
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
3.5H x 4.75W x 7.25L
Weight
2 lbs
Caution:
1. This product could become excessively hot and rupture in the
rare event of power line conditions or surge that exceed its
rated operating specification. Appropriate precautions should
be exercised.
2. High voltages are present on electrical termination. Unit should be
serviced by qualified personnel only.
mounting
Hole (4 places)
3/16" Dia.
Plate
3.5"
4.75"
6.75"
7.25"
11
AC Power — Series Connected
islatrol™ inXt120nl000-1
AC Power Line Filter
The Islatrol INXT120NL000-1 is a 120 VAC, 60A, EMI/RFI filter. The INXT is a
series connected device designed to filter electrical type transients impinging on
electrical distribution of a traffic control cabinet.
Features
■ 60 amp series filter
■ Epoxy encapsulated
■ 50 dB attenuation (200 KHz to 75 MHz)
■ 5 year warranty
■ High impact thermoplastic enclosure
general technical Specifications
Part Number
Islatrol INXT120NL000-1
Nominal Operating Voltage
120 VAC
Operating Voltage Range
120V ±25%
Operating Frequency Range
47–63 Hz
Connection Type
1/4 -20 Studs
Amperes
Phase Configuration
60 Amperes
Single Phase 2 Wire (Line and Neutral)
Size
Weight
Maximum Continuous Operating Voltage
(MCOV)
Load Surge Current Rating
10 MSEC
1 SEC
5 SEC
Transient Reduction/
Frequency Attenuation
Packaging
Operating Temperature
Operating Humidity
Operating Altitude
Warranty
12
3.2" x 4.4" x 2.0"
2 lbs.
240 VAC
100 x Nominal
10 x Nominal
5 x Nominal
50 dB min (200 KHz to 75 MHz)
Black, High Impact Plastic Case,
Epoxy Encapsulated
-40°C to +45°C
Derate Linearly to 70% @ 70°C
0 to 95% Non-condensing
-100m to 2000m
5 Years
AC Power — Parallel Connected
PowerSure™ emC-240B
120/240 VAC Heavy Duty (Parallel)
The PowerSure EMC-240B surge suppressor is designed to protect AC
distribution panel circuits or 120V power supplies feeding sensitive
electronic equipment. Electrically, the unit incorporates MOV and thermal
fusing technology. The PowerSure EMC-240B is designed to be installed in
parallel on standard single phase 120/240 VAC (3W + G) or single phase
120 VAC (2W + G) circuits.
Features
■ Fast response time
■ Operational status indicators
■ 40 kA per phase capacity
■ ANSI/UL 1449 Third Edition Type 2
■ Fused
■ 5 year warranty
general technical Specifications
mechanical
Maximum Operating Voltage
120/240 VAC
I Nominal (In)
2.8"
3 kA
Operating Current
2.2"
NA, Parallel
Total Peak Surge Current
80 kA (8 x 20 µs)
Operating Frequency
47–63 Hz
EMI Attenuation (100 kHz to 100 MHz)
> 40 dB
SPD Technology
4.5"
Metal Oxide Varistors (MOVs)
Modes Of Protection
Line-to-Line Line-to-Neutral
Status Indication
Power On & MOVs Functional
Connection Type
Wire Leads
Operating Temperature
18"
-40°C to +85°C
Dimensions (Inches)
4.6H x 2.2W x 2.8L
Weight
13.5 oz
Certification
ANSI/UL 1449 Third Edition, Type 2
Caution:
Installation and service should be performed by qualified electricians only.
Before installing EMC, remove all electrical power from circuits.
Connect on load side of main breakers. Use two dedicated 30A circuit breakers.
installation
120/240 VAC Service
120 VAC Service
L1
L
120 V
N
EMC-240B
240 V N
L2
120 V
240 V GND
120 V
EMC-240B
Black
Black
White
Green
Ground
N
Ground
L
240 VAC Service
L1
L2
240 V
240 V
Black
Black
White
Green
L2 N
L1
EMC-240B
Black
Black
White
Green
L2 GND L1
13
2.8
2.2
AC Power — Parallel Connected
PowerSure™ FAS-120AC
Medium Duty 120 VAC — Single Phase
The PowerSure FAS-120AC surge suppressor is designed to protect AC distribution
panel circuits or 120V power supplies feeding sensitive electronic equipment.
Electrically the unit incorporates MOV and thermal fusing technology. This device is
designed to be installed in parallel on standard single phase 120 VAC
(L, N, G) circuits.
Installation can be close-nipple up to a distribution panel/circuit or hardwired in
parallel up to power supply input terminal screws. Be sure to dress leads as short
as possible.
Features
■ LED indicator
■ Compact size
■ Fast response time
■ Liquid tight conduit fitting
■ Thermal fuse
■ ANSI/UL 1449 Third Edition Type 2
■ L-G, L-N, N-G protection
■ 5 year warranty
general technical Specifications
Part Number
mounting
PowerSure FAS-120AC
Maximum Operating Voltage
120 VAC
SPD Location Type
Type 2
I-Nominal (In)
3 kA
Operating Current
Peak Surge Current
NA
6.5 kA/Mode, 13 kA/Phase, 15.5 kA/Total
Operating Frequency
NA
SPD Technology
MOVs
L-N, L-G, N-G
Status Indication
Power On & MOVs Functional
Connection Type
Wire Leads
Operating Temperature
Dimensions (Inches)
2.5H x 1.5W x 3.0L
4 oz
ANSI/UL 1449 Third Edition, Type 2
Caution:
This product should be installed and serviced by qualified service
technicians or personnel only.
Remove power before installation or service.
Ø0.1860
-40°C to +85°C
Weight
Certification
1.5"
47–63 Hz
EMI Attenuation
Modes of Protection
14
2.5"
3"
AC Power — Parallel Connected
edco™ SPA-300
Medium Duty 120 VAC — Single Phase
The Edco SPA-300 is designed to protect sensitive electronic equipment, such as
traffic controllers, from high energy surges. The Edco SPA-300 incorporates MOV
technology which clamps these surges before equipment damage occurs.
The Edco SPA-300 is intended for use on bonded neutral to ground applications.
Features
■ 40 kA surge protection
■ Epoxy encapsulated
■ Fast response time
■ 5 year warranty
■ Solid-state design
general technical Specifications
Part Number
installation
Edco SPA-300
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
NA
Peak Surge Current
40 kA/Mode/Phase/Total
Operating Frequency
47–63 Hz
EMI Attenuation
NA
SPD Technology
MOVs
Status Indication
NA
Connection Type
1/4 -20 Stainless Steel Stud
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
Hot
120
VAC
Line
Neutral
1.875H x 2.875W x 5.25L
Weight
Load
SPA-300
Ground
1 lb
Caution:
This product should be installed and serviced by qualified service
technicians or personnel only.
mounting
Remove power before installation or service.
Hole 3/16"
Plate
2.875"
4.875"
5.25"
15
AC Power — Parallel Connected
edco™ SPA-100t
AC Service Protection
The Edco SPA-100T is a medium duty AC Service Arrester which is solid state
in design. It is intended for equipment which is located in outdoor cabinets
exposed to lightning transients. Application examples are railroad equipment,
motor control cabinets, flasher cabinets, and traffic controllers.
Features
■ Fast response time
■ Compact size
■ Solid-state design
■ 5 year warranty
■ Epoxy encapsulated
installation
general technical Specifications
Part Number
Edco SPA-100T
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
NA
Peak Surge Current
13 kA/Mode/Phase/Total
Operating Frequency
47–63 Hz
EMI Attenuation
NA
SPD Technology
MOVs
Status Indication
NA
Connection Type
10-32 Stainless Steel Stud
Operating Temperature
Dimensions (Inches)
CB
120 VAC
Input
Line
Hot
120 VAC
SPA-100T
Keep Leads
Short and
Straight
Neutral
Ground
-40°C to +85°C
0.5H x 1.5W x 2.0L
Weight
2 oz
Caution:
1. Install SPA-100T on load side of breaker as shown.
2. Installation and service should be performed by qualified personnel only.
mounting
3. Remove all electrical power from circuits before installing SPA-100T.
1" 1.5"
1.5"
2"
16
Load
AC Power — Parallel Connected
edco™ SHA-1201
120 VAC – Single Phase
The Edco SHA-1201 is specifically designed for type 170 traffic controller
cabinets that require power neutral to remain isolated from cabinet earth
ground. Protection is provided both between phase-to-neutral, and neutralto-ground.
If neutral is bonded to earth ground in the cabinet, the Edco SPA-100T unit
should be considered as a cost-effective alternate to the Edco SHA-1201.
Features
■ 53 kA surge protection
■ Epoxy encapsulated
■ Fast response time
■ 5 year warranty
■ Solid-state design
general technical Specifications
Part Number
installation
Edco SHA-1201
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
NA, Parallel
Peak Surge Current
40 kA/Mode, 40 kA/Phase, 53 kA/Total
Operating Frequency
Hot
NA
SPD Technology
MOVs
Modes of Protection
L-N, N-G
Status Indication
NA
Connection Type
Black
SHA-1201
47–63 Hz
EMI Attenuation
120 VAC
Neutral
Earth
Ground
Grnd.
Equipment
White
Chassis Ground
Leads
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
3L x 2W x 1H
Weight
6 oz
Caution:
Installation and service should be performed by qualified technicians
or service personnel only.
mounting
2"
1.5"
3"
2.5"
3/16"
Diameter Hole
17
low Voltage dC Power
edco™ FAS-1 and FAS-2 Series
One- and Two-Pair Signal Line Protection
The Edco FAS-1 and Edco FAS-2 Series are multi-stage one- pair or two-pair
surge suppressors designed for high-exposure applications. These products
were specifically designed to meet multiple, low voltage, protection applications
where operating currents can be as high as 2.5 amps.
Features
■ Lightning protection for low voltage data/
signal lines
■ Common mode and differential
mode protection
■ Multi stage protection
■ Automatic recovery
■ 5 year warranty
general technical Specifications
Part Number
Edco FAS-1 and FAS-2 Series
Maximum Operating Voltage
15, 24, 36, 52 VDC
Clamping Voltage
18, 33, 43, 60 VDC
Operating Current
2.5A
Peak Surge Current
< 0.1 dB at 10 MHz
GDT, SAD, w/Series Inductor
Operating Temperature
Dimensions (Inches)
10–14 AWG
-40°C to +85°C
FAS-1 = 1.5H x 1.5W x 2.8L
FAS-2 = 2H x 2W x 2.8L
FAS-1 = 3.5 oz
<3
FAS-2 = 7 oz
UL 497B
Protected Equipment
G RO UND I N G:
DO NOT1Sdaisy
intended for shield
T CHchain
O ICE:grounds.
USE AC NOT
P OWER
termination.
Install ground in accordance with all
GRO UND
applicable
2NDcodes.
CH O ICE: USE B U I LDI NG
18
12 VDC Use
FAS-1-033 HC (One-pair)
FAS-2-033 HC (Two-pair)
24 VDC Use
FAS-1-043 HC (One-pair)
FAS-2-043 HC (Two-pair)
24 VAC Use
48V Systems Use
*Not UL Listed
Line.
Terminal Block
w/Compression Lugs
Terminals Accept Up To 12 AWG
FAS-1-018 HC (One-pair)
FAS-2-018 HC (Two-pair)
FAS-1-060 HC (One-pair)*
FAS-2-060 HC (Two-pair)*
Ground Lug
Equip.
SPD Technology
Certification
Unprotected Or Field Side
0 to 10 MHz
Insertion Loss
Weight
ordering information
10 kA (8 x 20 µs)
Frequency Range
Connection Type
installation
Caution:
The hybrid design of this product includes series
resistance. Do not place this product in service on any
signal line capable of continuously supplying more than
2.5 amperes.
low Voltage dC Power
edco™ PHC Series
Two-Pair Signaling Circuit Protector (Modular)
The Edco PHC Series is designed to protect two pairs of wires specifically where
operating currents can be as high as 5 amps. Electrically, the Edco PHC Series
is a rugged series hybrid implementing a staged complement of MOVs, copper
wound inductors and Silicon Avalanche Diodes. This design reduces series
resistance to 0.2 Ohms per pair.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close as
practical to the protected equipment. Terminal 1 and/or terminal 10 should be
connected to Building-Approved Ground with 12- or 10-gauge solid wire.
Features
edCo PCB1B BASe Sold SePArAtely
■ Three-stage protection
■ Continuous current up to 5 amps
■ Differential protection
■ UL 497B listed
■ Common mode protection
■ Requires Edco PCB1B base
■ Plug-in module
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Automatic recovery
■ 5 year warranty
■ Fast response time
general technical Specifications
Part Number
Edco PHC Series
Maximum Operating Voltage
15, 20, 30, 36, 43, 60, 70, 150 VDC
Operating Current
5A
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
10 kA (8 x 20 µs)
Odd Terminals
Unprotected Pair 2
{
Field Side
Unprotected Pair 1
{
Even Terminals
8
7
6
5
4
3
2
1
-40°C to +85°C
3.7H x 1.75W x 2.375L
(PHC + PCB1B Base)
Weight
}
P H C
Protected Pair 2
Electronics Side 2.125" 2.4"
}
Protected Pair 1
Keying Pin
< 0.1 dB at 10 MHz
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Voltage Clamp
10
9
0 to 10 MHz
MOV, SAD, w/Series Inductor
How to Specify the Appropriate model
PCB1B:
12, 18, 24, 36, 52, 70,
120 VDC
Clamping Voltage
ordering information
terminal Assignments
1.0
Ground Terminal 1 or 10 to Building-Approved Ground
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
0 1 5
15 Volts
0 2 0
20 Volts
0 3 0
30 Volts
0 4 3
43 Volts (For Horn, Bell, Strobes)
0 6 0
60 Volts
S P 7 0
*100 Volts
1 3 0 R M S
*150 Volts
(For 120V Signal Lines)
*Not UL Listed
dimensions
8 oz
Certification
UL 497B
Applications Part number
24V Horn, Strobe, Bell
70V Speaker Lines
PHC-043 & PCB1B
PHC-SP70 & PCB1B
19
input Files/loop detection
edco™ SrA-6lC Series
Vehicle Loop Detection
The Edco SRA-6LC Series are three terminal devices, two of which are connected
across the signal inputs of the detector for differential mode protection, and the
third is grounded to protect against common mode damage.
This unit addresses over-voltage transients on both Common and Differential
modes with state-of-the-art silicon breakover devices. The Edco SRA-6LC Series
is intended for all popular makes of loop detectors presently on the market.
Features
■ Differential and common mode
protection
■ Epoxy encapsulated
■ Fast response time
■ 5 year warranty
■ Easy installation
■ Compatible with digital detectors
general technical Specifications
installation
ordering information
Part Number
General: Units are installed as close as practical
to the point where the detector loop wires enter
the controller cabinet. Connect one of the leads
to each loop. The common (either the bolt,
green wire or center clip) connection must be
connected to earth ground. Best performance
is obtained by shortening the leads as much as
possible, and providing the lowest impedance to
ground. One Edco SRA-6LC is used on each loop
detector circuit to be protected.
SRA-6LC
Edco SRA-6LC
Maximum Operating Voltage
75 VDC
Clamping Voltage
130 VDC
Operating Current
NA
Peak Surge Current
250A
SPD Technology
Silicon Breakover Device
Operating Temperature
Weight
Dimensions:
SRA-6LC
SRA-6LC w/Leads
Mounting:
SRA-6LCA-716
SRA-6LCA-916
SRA-6LCB
SRA-6LCBLL
-40°C to +85°C
3 oz
1.2" Square Cube
1.2" Square Cube
7/16" Terminal Strip Spacing
9/16" Terminal Strip Spacing
9/16" Terminal Strip Spacing
9/16" Terminal Strip Spacing
The Edco SRA-6LCA slips under the equipmentside screws of the terminal strip. (See Drawing A)
The protector ground is the center spade of the
3 spade terminations. The terminal strip must
jumper this corresponding position to ground.
Protectors can be mounted consecutively along
the terminal strip.
drawing A
Edc
o
Edc
o
The Edco SRA-6LCB slips under the equipmentside screws of the terminal strip. The protector
ground wire must be bonded in a short, direct
manner to the cabinet power ground. Protectors
can be mounted consecutively along the
terminal strip.
The Edco SRA-6LC has mounting brackets
available for installing multiple units in the
controller cabinet. The brackets are capable of
mounting four or eight devices in-line.
20
Cube, 2 leads + stud
SRA-6LC w/Leads
Cube, 3 leads/no stud
SRA-6LCA-716
3 Spaded Term. Block
7/16 Spacing
SRA-6LCA-916
3 Spaded Term. Block
9/16 Spacing
SRA-6LCB
2 Spaded Term. Block
w/3.5" Gnd. Wire
SRA-6LCBLL
2 Spaded Term. Block
w/11" Gnd. Wire
Caution:
Installation and service should be performed by
qualified technicians or service personnel.
input Files/loop detection
edco™ SrA16C-1
Vehicle Loop Detection
The Edco SRA16C-1 is a three terminal device, two of which are connected
across the signal inputs of the detector for differential mode protection, and the
third is grounded to protect against common mode damage.
Differential mode surges (induced voltage across the loop detector input
terminals) are instantly clamped by a semiconductor array. The array is designed
to appear as very low capacitance to the detector.
Common mode surges (induced voltage between the loop leads & ground)
are handled by a rugged three-element gas discharge tube which operates
(fires) at 90 VDC and thereafter clamps the two loop leads to 30 volts in respect
to ground. This design eliminates any ground noise from entering the loop
detector and being amplified. The Edco SRA16C-1 is intended for all current
detector models on the market.
Features
■ Rugged gas tube protection
■ Compatible with digital detectors
■ 5 year warranty
general technical Specifications
installation
Part Number
Edco SRA16C-1
Maximum Operating Voltage
75 VDC
Clamping Voltage
90 VDC
Operating Current
NA
Peak Surge Current
10 kA
SPD Technology
GDT
Connection Type
Leads
Operating Temperature
-40°C to +85°C
Dimensions
1" Sq., Ht. 2" Max.
Mounting
No. 10 - 32 x 3/8" Stud
Weight
3 oz
Mounting brackets are available for installing multiple units in the
controller cabinet. The brackets are capable of mounting four or
eight devices in-line. One Edco SRA16C-1 is used for each loop detector
to be protected.
Units are installed as close as practical to the point where the detector
loop wires enter the controller cabinet. Connect one of the flexible
leads to each end of the loop. The common (bolt) connection on each
Edco SRA16C-1 must be connected to earth ground.
Best performance is obtained by (1) shortening the flexible leads as much
as possible, and (2) providing the lowest possible impedance to ground.
NOTE:
The Edco SRA16C-1 w/Leads (special order) is installed very
similar to the standard unit except the common (bolt) is
replaced with a green wire.
edco™ mrA-6lC-6
Vehicle Loop Detection Protector
The Edco MRA-6LC-6 is a modular device utilizing solid state silicon foldover technology.
The Edco MRA-6LC-6 is designed for any traffic controller cabinet equipped with
6 position, 5.08 mm spacing sockets wired in-line with load relay outputs.
Features
■ Modular design
■ Differential and common mode protection
■ Fits 6 position, 5.08 mm spacing sockets
■ 5 year warranty
■ Designed for digital detector
general technical Specifications
Part Number
Maximum Operating Voltage
Edco MRA-6LC-6
Clamping Voltage
130 VDC
Operating Current
NA
Peak Surge Current
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
2 oz
75 VDC
250A
Silicon Breakover Device
6 Position 5.08 mm Euroblock
-40°C to +85°C
2H x 0.7W x 1.5L
installation
One Edco MRA-6LC-6 is used for each two loop detectors to be protected.
Units are installed as close as practical to the point where the detector loop
wires enter the controller cabinet.
Caution:
Installation and service should be performed by qualified technicians or
service personnel.
21
output Files
edco™ SPA-303
120 VAC Load Relay
The Edco SPA-303 is a three circuit protective device intended for use on traffic
control load relay outputs. The protector is furnished with three leads and a
ground stud.
Features
■ 5 year warranty
■ Convenient mounting/grounding stud
■ Compact size
mounting
general technical Specifications
Part Number
Edco SPA-303
Maximum Operating Voltage
120 VAC
Clamping Voltage
395 VAC
Operating Current
NA
Total Peak Surge Current
39 kA
Operating Frequency
47–63 Hz
EMI Attenuation
NA
SPD Technology
MOVs
Status Indication
NA
Connection Type
Leads
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
1.5"
SPA-303
5/8"
Caution:
To prevent shock hazard,
this product should never be
ungrounded (bolt disconnected
from ground) when power is
applied to leads.
1"
1.5H x 1W x 2.125L
Weight
5 oz
2.125"
edco™ mPA-303 Series
Modular Output File Protector
The Edco MPA-303 Series is a modular device intended for use on traffic control
load relay outputs. The Edco MPA-303-9 unit will protect six output circuits.
The Edco MPA-303-6 unit will protect four output circuits.
The Edco MPA-303-9 is designed for any traffic controller cabinet equipped with
9 position, 5.08 mm spacing sockets wired in line with load relay outputs. The
Edco MPA-303-6 is designed for 6 position, 5.08 mm spacing sockets.
Features
■ Modular design for 6 and 4 output circuits
■ 5 year warranty
■ Fits 6 and 9 position, 5.08 mm spacing sockets
general technical Specifications
Part Number
Connection Type
120 VAC
Operating Temperature
Clamping Voltage
340 VAC
Dimensions (Inches, Module only)
Operating Current
Total Peak Surge Current
Operating Frequency
22
Edco MPA-303 Series
Maximum Operating Voltage
NA
Weight
6 or 9 position 5.08 mm Euroblock
-40°C to +85°C
2.0H x 0.7W x 2.0L
2 oz
26k (6 pos), 39k (9 pos)
47–63 Hz
EMI Attenuation
NA
SPD Technology
MOVs
Status Indication
NA
Caution:
This product could become excessively hot and rupture in the rare event of power
line conditions or surge that exceed its rated operating specification. Appropriate
precautions should be exercised. High voltages are present on electrical termination.
Unit should be serviced by qualified personnel only.
Communication lines
edco™ PC642 Series
Zone/Loop/Data
The Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components.
In addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance by several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
performance and survivability.
The Edco PC642 card edge module is gold plated, double-sided, and is designed
to mate with the Edco PCB1B gold-plated female terminal connector. When
snapped together, the data circuits “pass thru” the protector in a serial fashion
from the four “Field Side” terminals to the four “Electronics Side” terminals.
Terminals 1 or 10 of the Edco PCB1B must be attached to Building-Approved
Ground per Edco Technical Bulletin # 2015.
edCo PCB1B BASe Sold SePArAtely
oPtion:
din rAil Kit AVAilABle
order PArt # 11604Kit-PC
Features
general technical Specifications
Part Number
■ Three-stage hybrid protection
■ Fast response time
■ Sneak/fault current protection
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ Low capacitance option
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Plug-in module
■ 5 year warranty
terminal Assignments
Edco PC642 Series
PCB1B:
Maximum Operating Voltage 5, 12, 18, 24, 30, 36,
Odd Terminals
43, 52, 180 VDC
Clamping Voltage
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
8, 15, 20, 30, 36, 43,
50, 60, 200 VDC
Terminal Block
w/Compression Lugs
Terminals Accept Up To 10 AWG
Weight
Certification
{
Unprotected Pair 1
10
9
8
7
6
5
4
3
2
1
}
}
Ground Terminal 1 or 10 to Building-Approved Ground
VOLTAGE CLAMP
8 Volts
15 Volts
20 Volts
30 Volts
36 Volts
43 Volts
50 Volts
60 Volts
*200 Volts
•Not UL Listed
0
0
0
0
0
0
0
0
2
0
1
2
3
3
4
5
6
0
8
5
0
0
6
3
0
0
0
D
X
LC
no suffix
stage 2 clamp
each line-to-ground
stage 2 clamp line-to-line only
recommended for traffic comm. lines
stage 2 clamp line-to-line
and each line to ground
low capacitance option stage
2 clamp line-to-line and each
line to ground
use “d” Suffix for traffic
Communication lines
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
ordering information
Application:
PC642
RS485, RS422:
E-NET, 10 BASE T:
UL 497B
PC642C-008LC & PCB1B
RS423, Token Ring: PC642C-008LC & PCB1B
RS232:
1 oz
Caution: The hybrid design of this product includes
series resistance. Do not place this product in service
on any signal line capable of continuously supplying
more than 150 milliamperes.
Protected Pair 1
Keying Pin
-40°C to +85°C
2H x 1W x 2.5L
(PC642 + PCB1B Base)
Protected Pair 2
Electronics Side 2.125" 2.4"
1.0
0 to 20 MHz
Connection Type
Dimensions (Inches)
Field Side
PC642C Even Terminals
10 kA (8 x 20 µs)
GDT, SAD, w/Series PTC
Operating Temperature
{
Unprotected Pair 2
0.15A
< 0.1 dB at 20 MHz
SPD Technology
How to Specify the Appropriate model
4–20ma:
PC642C-020 & PCB1B
PC642C-030LC & PCB1B
PC642C-036 & PCB1B
PCB1B
23
Communication lines
edco™ SrA64 Series
Single Pair Data/Signal
The Edco SRA64 Series surge suppressor is a single pair cube implementing
three-stage hybrid technology. This cube addresses over voltage transients
with gas tubes and silicon avalanche components. In addition, sneak and fault
currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance
several orders of magnitude when over currents exceed safe levels. A normal
state resumes when over currents are removed. The ability to self restore in this
manner significantly increases suppressor performance and survivability.
The standard Edco SRA64 second stage clamps are placed from each signal lineto-ground. In certain cases, where ground potentials vary from site-to-site, a
line-to-line only second stage clamp may be preferred. This variation is specified
by a suffix “D” on the part number. In other cases, line-to-line and line-to-ground
second stage clamps may be preferred. This variation uses an “X” suffix on the
part number.
A variety of clamping voltages are available as standard. Reference the “How To
Specify The Appropriate Model” section to ensure that a complete part number
description is obtained.
Features
■ Lightning protection for balanced low
voltage signal lines
■ Common mode protection
■ Multi-stage protection
■ Fast response time
■ Sneak/fault current protection
■ Flame retardant epoxy encapsulated
■ Differential mode protection
■ 5 year warranty
general technical Specifications
Part Number
How to Specify the Appropriate model
10kA (8 x 20 µs)
Response Time
<1 Nanosecond
Resistance
Temperature
Weight
Dimensions
Mounting Stud (standard)
SRA64C -
Edco SRA64 Series
Total Peak Surge Current
Clamping Voltage
■ Automatic recovery
8, 12, 15, 20, 30, 36, 43, 50, 60, or 200 VDC
5Ω (typical)
-40°C to+85°C
2 oz
1.15" Cube
No.10-32 x 1/2"
VOLTAGE CLAMP
8 Volts
12 Volts
15 Volts
20 Volts
30 Volts
36 Volts
43 Volts
50 Volts
60 Volts
*200 Volts
0
0
0
0
0
0
0
0
0
2
0
1
1
2
3
3
4
5
6
0
8
2
5
0
0
6
3
0
0
0
D
no suffix
stage 2 clamp
each line-to-ground
stage 2 clamp
line-to-line only
X
stage 2 clamp line-to-line
and each line to ground
*Not UL Listed
Caution:
The hybrid design of this product includes series resistance. Do not place this
product in service on any signal lines capable of continuously supplying more than
150 milliamperes.
wiring Assignments
Black
White
Field Side
(Outside Plant)
Electronics Side
(Equipment)
Black/Red
24
White/Red
Communication lines
edco™ SPA-60B Series
120 VAC Interconnect Signal
The Edco SPA-60B is an economical method of protecting circuitry associated
with 120 VAC interconnect signal lines commonly used in traffic control systems.
In the presence of normal interconnect line voltage and frequency (60 Hz),
the Edco SPA-60B possesses the ideal characteristics of high impedance across
the protector and no impedance in series with the line. In the presence of
transients, the protector appears as very low impedance, thereby shunting
the surge to ground.
The product is offered in four variations. The Edco SPA-60BL protects one
circuit and is furnished with two leads. The Edco SPA-60BL-2 is identical except
it protects two circuits and is furnished with three leads.The Edco SPA-60BS
protects one circuit and consists of one lead and a stud (also used for mounting).
The Edco SPA-60BS-2 is identical except it protects two circuits and consists of
two leads and a stud. Refer to ordering information below.
Features
■ Rugged gas tube protection
■ Various models available
■ Fast response time
■ 5 year warranty
■ Compact size
general technical Specifications
Part Number
installation
Edco SPA-60B Series
Maximum Operating Voltage
120 VAC
Clamping Voltage
350 VAC
Operating Current
Total Peak Surge Current
Operating Frequency
NA
10 kA
47-63 Hz
EMI Attenuation
NA
SPD Technology
GDT
Status Indication
NA
Connection Type
Leads
Operating Temperature
-40°C to +85°C
Size:
BL Types
BS Types
1.50" x .5" x .8"
1" cube
Mounting Studs
10:32 x 3/8" SS
Weight
Stud mounting unit:
Connect black lead to interconnect signal line near entry point into
cabinet. Shorten lead as much as possible. Bolt unit to clean metal surface
bonded to power/earth ground (cabinet in most cases).
lead Supported unit:
Shorten leads. Connect between interconnect signal line and power/
earth ground.
ordering information
SPA-60B
L
Leads
One Circuit
(blank)
S
Studs
Two Circuits 2
2 oz
Note:
This product is intended for use on 120 VAC interconnect lines.
Do NOT use on AC service or power lines.
25
Video
edco™ CX Series
CCTV & Data Applications/Coax
The Edco CX Series Surge Protective Devices (SPDs) implement three-stage
hybrid technology. The SPDs address over-voltage transients with a primary
Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD)
components. Over-current protection, e.g. sneak and fault currents, are
mitigated with solid-state resettable fuses —PTCs. The Edco CX Series SPDs
are designed in accordance with NFPA 780 (2004 edition) requirements,
with up to 20 kA of surge current capability. The Edco CX06-MI model has an
isolated ground and is recommended for use at the camera end.
oPtion:
din rAil Kit AVAilABle
order PArt # 11604Kit-CX
Features
■ Sneak/fault current protection
■ CX06-MI has an isolated ground
■ Low insertion loss
■ 5 year warranty
■ Shielded case
general technical Specifications
ordering information
Maximum Operating Voltage
5 VDC
Connection Type
Clamping Voltage
6 VDC
Operating Temperature
0.17A
Dimensions (Inches)
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
20 kA (8 x 20 µs)
0 to 20 MHz
< 1 dB at 20 MHz
GDT, SAD, w/Series PTC
Weight
Certification
BNC, 50/75 Ohms
-40°C to +85°C
M = 1.5H x 1W x 3.25L
MI = 1.5H x 1W x 4L
SBL = 1.7H x 1.4W x 2.8L
M = 2.3 oz MI = 3 oz
UL 497B
CX06-mi-SBl installation
26
CX06-M
CX06-MI
CX06-MI-SBL
Head End
Camera End
• Other configurations available — please consult
factory
Video
edco™ HVCP-48
Video Control Power Protection
The Edco HVCP-48 is a hybrid surge protection product featuring DC power, data and video
protection in one package. Each separate circuit is capable of handling high-current impulses
while tightly clamping transients and allowing critical power and data to be transmitted.
Features
■ Three separate hybrid circuits
■ Ultra low capacitance, low signal loss
■ Balanced transition circuit
■ Rugged gas tube protection
■ Shielded case
■ 5 year warranty
general technical Specifications
Operating Voltage
Maximum Operating Current
Clamping Voltage
Total Peak Surge Current Rating
SPD Technology
High Speed Data Protection (SDIO)
Clamping Voltage
Total Peak Surge Current Rating
SPD Technology
Video Protection
Clamping Voltage
Total Peak Surge Current Rating
SPD Technology
installation
48 VDC
1 Amp
70 VDC
10 kA
GDT, SAD, Series Element
Operating Temperature
Operating Humidity
Environmental
5
-
+
Gnd. +
4
3
2
1
Field
HVCP-48
Chassis
Ground
2V
10 kA
GDT, SAD, Series Element
12 AWG, 36.0" Long
Mounting
6
VS
10 kA
Ground Wire
Weight
+
GDT, SAD, Series Element
6 Position 5.08 mm
Header & Plug (28 -12 AWG)
Material
-
Video
15V
Connections
Dimensions (Inches)
SDIO
3.3 L x 3.3 W x 1.35 H
6
5
4
3
-
+
-
+
SDIO
Video
2
1
Gnd. +
Protected
VS
High Impact Plastic
12 oz
Flange Mounted, 3.75" Mtg. Hole
Distance, (.188 dia.) (2x)
DIN Rail Mounting (Optional)
-40°C to +74°C
0% to 95% Non-condensing
RoHS Compliant
27
modem
edco™ FAS-tel-dot
RJ Connection Telephone Protection For Traffic Cabinets
The Edco FAS-TEL-DOT is a single pair telephone protector that implements an advanced
three-stage hybrid design. This unit addresses over-voltage transients with gas discharge
tubes (GDT) and silicon breakover devices. Additionally, sneak and fault currents are
mitigated with PTC technology, which consists of solid state resettable fuses. The Edco
FAS-TEL-DOT is specifically designed for more rugged applications such as traffic cabinets.
Features
■ Three-stage hybrid design
■ Fast response time
■ Rugged gas tube protection
■ 5 year warranty
■ Sneak/fault current protection
installation
general technical Specifications
Part Number
Edco FAS-TEL-DOT
Maximum Operating Voltage
220 VDC
Clamping Voltage
270 VDC
Operating Current
0.15A
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
10 kA
0 to 20 MHz
FAS-TEL-DOT
To Phone or Computer
Protected
Side
< 0.1 dB at 20 MHz
GDT, Silicon Breakover w/PTC
R1
T1
Term Block, Comp. Lug IN/RJ OUT
-40°C to +85°C
1H x 2W x 2L
TELCO
R
2 oz
Unprotected
Side Field
28
T
Building Approved Ground
data/Signal line
edco™ rJA-rJd Series
RJ-45 Telephone/Data
The Edco RJA and Edco RJD Series are four pair telephone/data-line protectors
that implement advanced, two stage, hybrid design. These units address overvoltage transients with silicon breakover devices, while sneak and fault currents
are mitigated with PTC technology, which consists of solid state resettable fuses.
The Edco RJA and Edco RJD Series incorporate RJ-45 female jacks in and out. The
Edco RJA voltage clamp is set for C.O. Trunks and Analog Telephone Extensions
(with ring in voltage), and the Edco RJD voltage clamp is set for Digital
Extensions (no ring in voltage).
Features
■ <1 nanosecond response time
■ Solid-state resettable fuses-PTCs
■ Silicon breakover technology
■ Low capacitance
■ Line-to-line protection
general technical Specifications
Part Number
■ Tip and ring to ground protection
■ CAN/CSA C22.2, No. 226-92 compliant
■ UL 497A listed
■ 4 pair protection
■ 5 year warranty
installation
ordering information
Edco RJA-RJD Series
RJA-45
Analog Phone
Maximum Operating Voltage
48, 220 VDC
RJD-45
Digital Phone
Clamping Voltage
55, 280 VDC
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Certifications
0.15A
200 A (10 x 1000 µs)
0 to 50 MHz
< 0.1 dB at 50 MHz
Silicon Breakover
Devices w/Series PTC
RJ-45 Jacks
-40°C to +85°C
1.0H x 2.5W x 4.25L
3 oz
UL 497A, CUL
Caution:
The Edco RJA and Edco RJD Series are intended
for indoor use only and shall be employed on the
equipment side of a listed primary telephone protector.
29
data/Signal line
edco™ SrS-Biu-15
NEMA TS-2 Port 1 Protector
The Edco SRS-BIU-15 is a 15 pin surge suppressor used for protection of all
devices on Port 1 Synchronous Data Link Control (SDLC).
Features
■ All other pins provide pass thru connection
■ Pins surge protected are 1, 3, 5, 7, 9,
11, 13 and 15
■ Independent pass thru pins are 12 and 14
■ 1500 watts of protection in each direction
(positive or negative impulse)
■ 5 year warranty
■ Pass thru pins are 2, 4, 6 and 8
connected together
■ External grounding connected to pin 12
general technical Specifications
Pin out
Maximum Operating Voltage
5 VDC
Pin
Function
Clamping Voltage
8 VDC
1
Rx Data +
Operating Current
1.5A
2
Logic Ground
47A (10 x1000 µs)
3
Rx Clock +
Logic Ground
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
30
■ 8 high-speed, low-capacitance, surgeprotected pins – allows high speed
data transfer
0 to 20 MHz
4
< 0.1 dB at 20 MHz
5
Tx Data +
SAD
6
Logic Ground
DB-15
7
Tx Clock +
-40°C to +85°C
8
Logic Ground
1.5H x 0.625W x 2.25L
9
Rx Data -
1.25 oz
10
Port 1 Disable
(0 VDC = disable)
11
Rx Clock -
12
Earth Ground
13
Tx Data -
14
Reserved
15
Tx Clock -
Highway lighting
edco™ SHA Series
Highway Lighting Protection
The Edco SHA Series provides surge protection for highway lighting/street pole
applications. The suppressor is encapsulated in a weatherproof enclosure that is
installed right inside the pole.
The SHA Series is available in 120V, 240V, 277V and 480V Single Phase models.
In addition, optional Low Capacitance (LC) and Both Black (BB) leads models
are offered.
Features
■ Weatherproof
■ Solid-state design
■ No follow current
■ Various options available
■ Line-to-ground protection
■ 5 year warranty
■ Neutral-to-ground protection
general technical Specifications
Part Number
installation
Edco SHA-Series
Maximum Operating Voltage
120, 240, 277, 480 VAC
Clamping Voltage
395, 710, 850, 1500 VAC
Operating Current
NA
Total Peak Surge Current
Black L1 IN
To
Source
39 kA
Operating Frequency
Green
47–63 Hz
EMI Attenuation
NA
SPD Technology
MOVs
Modes of Protection
L-G, N-G
Status Indication
NA
Connection Type
Leads
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
0.8H x 2.875W x 5.3L
Weight
1 lb
L1 Out Black
Edco
SHA
Series
White L2 IN
gauge
Color
Connection
22"
6
Green
Ground
12"
10
Black
L-1 (Hot)
12"
10
White
L-2 (Neutral or Hot)
L2 Out White
Caution:
Installation and service of this product should be performed by qualified
personnel only.
models
SHA-1203, SHA-2403, SHA-4803
leads length
To
Ballast
SHA-2773 (available upon request)
SHA-4803BB (Both leads Black)
SHA-_ _ _ _LC (Low Capacitance option)
Standard
Special
31
Highway lighting
edco™ SHAS Series
Highway Lighting Protection
The Edco SHAS Series Highway Lighting Protector is a smaller version of the
popular Edco SHA Series. It easily fits into a 3" x 5" hand hole and incorporates
the use of TMOVs (MOVs with a thermal cutoff) and an LED. Should the unit’s
TMOVs degrade as a result of either a large surge or over time due to multiple
surges, the LED will go out. This will enable the maintenance personnel to easily
identify if the protection is lost and the unit needs replacing. The Edco SHAS
Series also has about 30% less capacitance, thus eliminating the need to require
a low capacitance version.
Features
■ Neutral-to-ground protection
(120V model)
■ Weatherproof
■ No follow current
■ LED surge “OK” indicator
■ Line-to-ground protection
■ 5 year warranty
general technical Specifications
model
installation
SHAS-120
SHAS-240
SHAS-277
SHAS-480
36 kA
36 kA
36 kA
36 kA
<25
<25
<25
Clamp Voltage; @ 1 ma (V peak) 240
@ 200 Amps
395
430
710
430
710
Max. Allowable Voltage
(AC RMS)
275
275
550
Total Peak Surge Current
(8 x 20 µs)
Response Time (nanoseconds)
150
<25
B
l
a
c
k
B
l
a
c
k
910
1500
L1
L2
Current Drain (microamps)
120
175
175
130
Insulation to Ground (volts)
>600
>600
>600
>600
120 VAC
240 VAC
277 VAC
480 VAC
Lighting Application
Dimensions
lead length
Load
2"
2.5"
1.5"H x 2"L x 2"W
wiring
gauge
Color
Connection
2"
Line
L1
L2
B
l
a
c
k
B
l
a
c
k
ordering information
22"
12
Green
Ground
model
12"
12
Black
L-1 (hot)
SHAS-120
12"
12
Black
L-2 (Neutral or Hot)
SHAS-240
SHAS-277
SHAS-480
32
1.5"
Green
To
Ground
notes
33
Headquarters
Surge Protection
100 Emerson Parkway
Binghamton, NY 13905
T: 607-721-8840
T: 800-288-6169
F: 607-722-8713
E: contactsurge@emerson.com
emerson network Power.
The global leader in enabling Business-Critical ContinuityTM.
emersonnetworkPower.com/surge
AC Power
Connectivity
Embedded Computing
Embedded Power
Outside Plant
Power Switching & Controls
Racks and Integrated Cabinets
Services
DC Power
Monitoring
Precision Cooling
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages
resulting from use of this information or for any errors or omissions.
SL-50100 Rev.1 8/10 Printed in USA
Download