Surge Protection TM For Business-Critical Continuity Transportation Surge Protection Product Catalog Keeping Power Clean And Green Power Protection To Keep Traffic Flowing Smoothly … Think about the challenge of navigating rush-hour traffic, even on a good day. Then imagine the havoc and congestion that power surges, spikes, noise and transients can create, turning your commute into a nightmare. When traffic signaling equipment goes down, it creates a ripple effect. Even when you’re up and running again, the unfortunate effects can resonate for hours after an occurrence. For more than 35 years, Edco™ surge protection products have been protecting equipment against these potentially catastrophic occurrences. Whether it’s highway lighting, traffic signals, controller cabinets, cameras, high speed/commuter rail, dynamic message signs, toll roads, weigh stations and red light/speed enforcement or sophisticated intelligent systems, rest assured that Emerson Network Power Edco products deliver the mission-critical protection you need to keep all your sensitive equipment operating as expected. Emerson Network Power Surge Protection manufactures power quality solutions in the following categories: AC Power Surge Protection • Limit high-voltage spikes to an acceptable level Filtering/Line Conditioning • Protect against low-energy transients and high frequency noise Data/Signal Line Protection • Guard sensitive instrumentation against what we refer to as “backdoor” transients and noise Why put your equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind. We provide solutions for all your application needs and the foundation for Business-Critical Continuity™. We are committed to providing quality products, competitive pricing and reliable customer care. If you have any product application or pricing questions, please call us at 800-288-6169. We look forward to hearing from you. We’re here to help! Products Table of Contents Page # AC Power — SerieS ConneCted Edco™ ACP-340 — 120 VAC — Single Phase Edco™ ACP-340LED/540LED —120 VAC — Single Phase/240 VAC — Single Phase Edco™ SHA-1210 —120 VAC — Single Phase Edco™ SHP Series —120 VAC — Single Phase/240 VAC — Single Phase Filter, 120 VAC or 240 VAC Edco™ SHA-1250 — 120 VAC — Single Phase — Modular Edco™ HSP Series — 120 VAC Heavy Duty 120 Volt AC Islatrol™ — SP-6TVN — Plug-in Surge Protection/Active Tracking™ Filter Islatrol™ — RM Series — 120 VAC Rackmount Edco™ SHA-1230FS — 120 VAC — Single Phase — 30A FingerSafe Edco™ SHA-1260 — 120 VAC — Single Phase — 60A Islatrol™ INXT120NL000-1 — AC Power Line Filter 2 3 4 5 6 7 8 9 10 11 12 AC Power — PArAllel ConneCted PowerSure™ EMC-240B — 120/240 VAC Heavy Duty (Parallel) PowerSure™ FAS-120AC — Medium Duty 120 VAC — Single Phase Edco™ SPA-300 — Medium Duty 120 VAC — Single Phase Edco™ SPA-100T — AC Service Protection Edco™ SHA-1201 — 120 VAC — Single Phase 13 14 15 16 17 low VoltAge dC Power Edco™ FAS-1 and FAS-2 Series — One- and Two-Pair Signal Line Protection Edco™ PHC Series — Two-Pair Signaling Circuit Protector (Modular) 18 19 inPut FileS/looP deteCtion Edco™ SRA-6LC Series — Vehicle Loop Detection Edco™ SRA16C-1 — Vehicle Loop Detection Edco™ MRA-6LC-6 — Vehicle Loop Detection Protector 20 21 21 outPut FileS Edco™ SPA-303 — 120 VAC Load Relay Edco™ MPA-303 Series — Modular Output File Protector 22 22 CommuniCAtion lineS Edco™ PC642 Series — Zone/Loop/Data Edco™ SRA64 Series — Single Pair Data/Signal Edco™ SPA-60B — 120 VAC Interconnect Signal 23 24 25 Video Edco™ CX Series — CCTV Applications/Coax Edco™ HVCP-48 — Video Control Power Protection 26 27 modem Edco™ FAS-TEL-DOT — RJ Connection Telephone Protection for Traffic Cabinets 28 dAtA/SignAl line Edco™ RJA-RJD Series — RJ-45 Telephone/Data Edco™ SRS-BIU-15 — NEMA TS-2 Port 1 Protector 29 30 HigHwAy ligHting Edco™ SHA Series — Highway Lighting Protection Edco™ SHAS Series — Highway Lighting Protection 31 32 AC Power — Series Connected edco™ ACP-340 120 VAC — Single Phase The Edco ACP-340 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters pass through. The Edco ACP-340 can replace the RFI filter when high attenuation of noise above 25 MHz is not required. If random time-base, memory loss, or other problems are affecting some of your intersections, this state-of-the-art protector can be of great benefit when properly installed. Features ■ Multi-stage hybrid design ■ Incorporates series choke ■ Industry-leading noise filtering ■ 5 year warranty ■ Nanosecond response time general technical Specifications installation Part Number Edco ACP-340 Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current 10A Peak Surge Current 32.5 kA/Mode, 39 kA/Phase Operating Frequency 120 / VAC Input 47–63 Hz EMI Attenuation 60 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication NA Connection Type 1/4-20 Stainless Steel Stud Operating Temperature Main Line Edco ACP-340 Main Neutral Gnd Earth Site Variable (option) Earth Line Out Neutral Out Protected Power Source (to controller and other sensitive electronics) -40°C to +70°C Dimensions (Inches) 2.375H x 3.125W x 7.125L Weight 1 lb 13.5 oz Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. mounting 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Hole (6 places) 3/16" Dia. 1.28" Plate 3.125" 1.28" 6.65" 7.125" 2 Cabinet Power AC Hot Bus AC Power — Series Connected edco™ ACP-340led/540led 120 VAC — Single Phase/240 VAC — Single Phase The Edco ACP-340LED is an upgrade to the popular Edco ACP-340, adding a failure indicator as well as remote sensing circuitry. In addition, this unit offers much better lightning protection than the standard Edco ACP-340. The Edco ACP-340LED/540LED filtering surge protectors absorb power line noise and switching transients that other suppressors and RFI filters pass through. They can replace the RFI filter when high attenuation of noise above 25 MHz is not required. The Edco ACP-340LED/540LED utilize Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally activated element designed to open in the event of overheating due to the abnormal over-voltage, limited current conditions. Features oPtion din rAil Kit AVAilABle order PArt # 11604Kit ■ 50 kA/Mode & 100 kA/phase surge current protection ■ Power On and failure LED ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ 5 year warranty installation general technical Specifications Part Number ■ Remote sensing circuitry Edco ACP-340LED/540LED Maximum Operating Voltage 120 VAC/240 VAC Clamping Voltage 395 VAC/775 VAC Operating Current Cabinet Power AC Hot Bus 15A Peak Surge Current 50 kA/Mode, 100 kA/Phase Operating Frequency 47–63 Hz EMI Attenuation 60 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication Power On & MOVs Functional Connection Type 1/4-20 Stainless Steel Stud Operating Temperature 120 / VAC Input Main Line Main Neutral Edco ACP-LED Series Neutral Out Gnd Earth Site Variable (option) Earth Line Out NC C NO To Remote Indication If Needed Protected Power Source (to controller and other sensitive electronics) -40°C to +85°C Dimensions (Inches) 1.875H x 3.25W x 5.75L Weight 1 lb Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. mounting Hole (4 places) 3/16" Dia. Plate 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. 2.25" 3.25" 5.25" 5.75" 3 AC Power — Series Connected edco™ SHA-1210 120 VAC — Single Phase The Edco SHA-1210 filtering surge protector absorbs power line noise and switching transients that other suppressors and RFI filters pass through. The Edco SHA-1210 can replace the RFI filter when high attenuation of noise above 25 MHz is not required. If random time-base, memory loss, or other problems are affecting some of your intersections, this state-of-the-art protector can be of great benefit when properly installed. Features ■ Multi-stage hybrid design ■ Incorporates series choke ■ 60 dB maximum noise filtering ■ 5 year warranty ■ Nanosecond response time installation general technical Specifications Part Number Edco SHA-1210 Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current 10A 120 VAC Input Earth 32.5 kA/Mode, 39 kA/Phase, 65 kA/Total 47–63 Hz EMI Attenuation 60 dB typ SPD Technology MOVs w/L-C Filter L-N, L-G, N-G Status Indication NA Connection Type 1/4-20 Stainless Steel Stud Operating Temperature Edco SHA-1210 Main Operating Frequency Modes of Protection CB Neutral Out AC Out AC In Protected Power Source (to controller and other sensitive electronics) Site Variable (option) Earth AC Hot Buss Cabinet Power -40°C to +70°C Dimensions (Inches) 2.375H x 3.125W x 7.125L Weight 2 lbs Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. mounting Hole (6 places) 3/16" Dia. 1.28" Plate 3.125" 1.28" 6.65" 7.125" 4 Neutral Buss Equipment Side Peak Surge Current Main Neutral AC Power — Series Connected edco™ SHP Series Single Phase Filter, 120 VAC or 240 VAC The Edco SHP Series hybrid design exhibits performance levels unattainable with simple “shunt type” protectors. The two active clamp stages, large inductor and shunt capacitance effectively halt high rate-of-rise surge waveforms, thus preventing initial voltage overshoot. Flexibility of installation is another design feature of the Edco SHP Series. The protector first and second stages are electrically separate (line side) for use in jurisdictions that require a line filter between stages. In addition, the first stage provides protection from MAIN NEUTRAL to GND as well as MAIN LINE to GND. This is an often overlooked feature which becomes significant in locales where NEUTRAL must be kept separate from earth ground inside the cabinet. Features ■ Multi-stage hybrid design ■ I ncorporates series choke ■ Nanosecond response time ■ 5 year warranty ■ Blocks high energy surges installation general technical Specifications Part Number Edco SHP300-10/SHP400-10 Maximum Operating Voltage 120 VAC/240 VAC Clamping Voltage 395 VAC/650 VAC Operating Current 10A Peak Surge Current CB 58.5 kA (8 x 20 µs) Cabinet Power AC Hot Line Filter (optional) Connection If Line Filter Is NOT Used Main Line Line In 120 VAC Input Operating Frequency 47–63 Hz EMI Attenuation 70 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection Main Neutral NA Connection Type 1/4-20 & 10-32 Stainless Steel Stud Operating Temperature -40°C to +85°C Dimensions (Inches) 1.8H x 2.875W x 5.3L Weight 1 lb mounting Line Out Neutral Out } Neutral Buss L-N, L-G, N-G Status Indication Edco SHP Series Earth Ground Earth Ground Protected Power Service (to controller and other sensitive electronics) Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. 3/16" Dia. (6 places) 1.17" 2.875" 1.17" 4.85" 5.30" 5 AC Power — Series Connected edco™ SHA-1250 120 VAC — Single Phase — Modular The Edco SHA-1250 is an upgraded version of the Edco SHA-1210. The Edco SHA-1250 also incorporates two LEDs for failure indication in a modular package (Utilizes 12 pin Beau connector). The hardwire terminal base (Edco SHA-1250BASE-A, ordered separately) accommodates all wiring and the protection module is designed for easy replacement. The footprint of the Edco SHA-1250-BASE-A is the same as the Edco ACP-340 and Edco SHA-1210. This makes retrofitting older cabinets easy because internal wire lengths do not have to be adjusted. The Edco SHA-1250 offers remote sensing circuitry output that is a dry relay contact closure suitable to interface with a modem or computer port for polling remotely. With this feature, a central computer could detect a failed Edco SHA-1250 at the intersection. SHA-1250 and SHA-1250-BASe-A (Sold Separately) The Edco SHA-1250 provides excellent noise suppression over a large frequency range. Typical noise attenuation is 10 dB @ 28 KHz, 54 dB @ 100 KHz and 50 dB @ 1 MHz. Features ■ Plug-in module ■ Remote-sensing circuitry ■ LED indication ■ Patented technology ■ Filtering ■ 5 year warranty general technical Specifications Part Number Edco SHA-1250 Maximum Operating Voltage 120 VAC Clamping Voltage 340 VAC Operating Current 15A Peak Surge Current 1.28" Plate 3.125" 1.28" 47–63 Hz EMI Attenuation 50 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection 6.65" 7.125" L-N, L-G, N-G Status Indication Power On & MOVs Functional Connection Type 1/4-20 SS Stud Base, Plug-in Module Operating Operating Temperature Dimensions (Inches, Module + Base) Weight (Module + Base) Hole (6 places) 3/16" Dia. 26 kA/Mode, 32.5 kA/Phase, 45.5 kA/Total Operating Frequency 6 mounting -40°C to +85°C 3.5H x 3.125W x 7.125L 1 lb 11.5 oz Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. AC Power — Series Connected edco™ HSP Series 120 VAC Heavy Duty 120 Volt AC The Edco HSP Series is an advanced three-stage hybrid, solid state powerline protector. Features such as noise filtering, common mode and normal mode suppression, nanosecond reaction time, power line tracking, and compression screw terminations make the Edco HSP Series an excellent choice in commercial and industrial applications. edCo HSP121Bt-1ru The Edco HSP Series offers a replaceable fuse designed to remove the load (protected equipment) from the line if the unit is either overloaded or the internal protection fails. This feature prevents surges from entering equipment through a failed protector not noticed by the user. Features ■ Fast response time ■ Three-stage hybrid design ■ Failure indicator ■ Replaceable fuse ■ Power line tracking ■ 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A) ■ Filtering ■ Polycarbonite NEMA 4X enclosure (HSP121A) edCo HSP121A general technical Specifications Maximum Operating Voltage 120 VAC Clamping Voltage 325 VAC Operating Current 15A I-Nominal (In) 3 kA Total Peak Surge Current dimensions Mounting – HSP121BT-1RU Holes 3/16" Dia. 39 kA (8 x 20 µs) Operating Frequency 47–63 Hz EMI Attenuation (100 kHz to 100 MHz) SPD Technology ■ 5 year warranty > 40 dB Light On – Normal Light Off – Requires Service Metal Oxide Varistors (MOVs) w/ L-C Filter Modes Of Protection Line-to-Neutral, Line-to-Ground, Neutral-to-Ground Status Indication Power On & MOVs functional Connection Type 3 Position, 20A Terminal Block w/Compression Screws Terminals Accept Up To 14 AWG Operating Temperature -40°C to +85°C Dimensions (Inches) Mounting – HSP121A Holes 3/16" Dia. 3/4" Conduit Fitting 3/4" Conduit Fitting GND 1/2" Conduit Fitting GND N N AC AC 1/2" Conduit Fitting HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L Weight Certifications 10 oz HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2 7 AC Power — Series Connected islatrol™ SP-6tVn Plug-in Surge Protection/Active Tracking™ Filter The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device that plugs into a standard duplex receptacle. It features uniquely designed repositionable outlets and protects against damaging power disturbances traveling through your wiring into your electrical outlets. Features ■ Plugs into standard 120V, 15A electrical outlet ■ Perfect for tight spaces, behind furniture and appliances ■ Total peak surge current capacity of 39 kA ■ Intelligent monitoring against improper wiring/grounding ■ Cables for telephone, video, and data connectors included rePoSitionABle outletS ■ Repositionable outlets rotate to accommodate available space ■ 60 dB maximum high frequency ■ Operational indicator lamp ■ 5 year warranty general technical Specifications AnSi/ieee C62.41 Cat A ringwave (6 kV, 200A, 100 kHz) AC Power Protection Nominal Operating Voltage 120 VAC, Single Phase Operating Voltage Range 120 VAC +/- 10% Operating Frequency Range 265V Common Mode 290V 47–63 Hz Rated Output 15A ANSI/IEEE C62.41 Category Category A & B Connection Type (6) 5-15R Receptacles and 5-15P Plug Phase Configuration 2 Wire + Gnd Size 7.5 x 4.75 x 1.75 (Inches) Enclosure High Impact Plastic Weight AnSi/ieee C62.41 Cat B ringwave (6 kV, 500A, 100 kHz) Normal Mode 275V Common Mode 290V Frequency response Normal Mode Common Mode L – N, L – G, N – G Indication of Suppression Status < .5 ns Normal Mode ANSI/UL 1449 Third Edition Type 3 Warranty Video 1 & 2 Phone network Connection Type Type “F” Type RJ-11 Type RJ-45 Cables Provided 6 (2x) Type “F” 6' Ends RJ-11 Male 6' Ends RJ-45 Male Ends 5 kA (8 x 20 µs) 2 kA (10 x 1000 µs) 3 kA (8 x 20 µs) 5 Year Peak Surge Current maximum Continuous operating Voltage (mCoV) 130 VAC Capacitance Protection Level Clamping Voltage (DC) Peak Surge Current (8 x 20 ms) 8 40 dB Maximum, Forward/Reverse, 5 MHz to 50 MHz low Voltage Protection Status Indicator Response Time Line To Neutral 60 dB Maximum, Forward/Reverse, 100 kHz to 50 MHz 2.0 lbs (0.9 kgs) Modes Of Protection Certification Normal Mode Line To Neutral 13 kA Line To Ground 13 kA Neutral To Ground 13 kA Total 39 kA Attenuation <12 pf <50 pf <70 pf L-G T-R, T-G, R-G L-G (8 Lines) 145 V 270-350 V 30 V 1 dB @ 2 Ghz N/A N/A AC Power — Series Connected islatrol™ — rm Series 120 VAC Rackmount This line of AC surge protectors is ideal for protecting the power feeding valuable rack equipment. All models provide ten protected outlets on the back and two protected convenience outlets on the front. This series provides 40,000 Amps of surge protection and up to 60 dB of highfrequency noise filtering. Status LEDs indicate the correct power is coming to the unit, whether the unit is properly grounded and whether the surge components are still intact. Units are available with an optional digital meter, mounted on the front of the unit, that will monitor the voltage, current and power of the protected equipment. model Shown: rm-115-10 rm Features ■ 40 kA surge protection ■ Digital meter ■ 60 dB max. noise filtering ■ Optional twist lock plug ■ 15 A & 20 A models available ■ 1 year warranty ■ Power, ground and surge status indicators general technical Specifications Part number Voltage Amperage Plug (nemA) receptacles (nemA) digital meter locking Plug RM-115-10RM 120 V 15 A 5-15P 5-15R Yes No RM-120-10RM 120 V 20 A 5-20P 5-20R Yes No rackmount AC Power Protection Rated Voltage 120 V Rated Current 15 A & 20 A Peak Surge Current Response Time EMI/RFI Filtering LED Indicators Digital Meter Input Power 15 A Models 20 A Models 20 kA/Mode, 40 kA/Phase <5 ns 60 dB Max. Green-Power On Green-Ground OK Green-Surge Circuit OK Voltage Amps, Watts, VA, Hz, PF, Kwh, and Clock Output Receptacles 15 A Models 20 A Models Thermal Protection Over-current Protection Front- (2) NEMA 5-15R Back- (10) NEMA 5-15R Front- (2) NEMA 5-20R Back- (10) NEMA 5-20R Thermal Protected MOVs Circuit Dimensions 1.75"H x 19"W x 2.0"D (1U) Certification ANSI/UL1449 Third Edition, Type 3 Warranty 1 Year SJT 14/3C Power Cord (15 ft) with NEMA 5-15P Plug SJT 12/3C Power Cord (15 ft) with NEMA 5-20P Plug NEMA L5-20P Plug- Optional 9 AC Power — Series Connected edco™ SHA-1230FS 120 VAC — Single Phase — 30A FingerSafe The Edco SHA-1230FS is a FingerSafe 120 VAC Single Phase 2W+G, 30A surge suppressor/filter designed to shunt electrical type transients affecting the electrical distribution inside a traffic cabinet. The Edco SHA-1230FS offers 50 kA per mode and 100 kA per phase of surge current protection. The Edco SHA-1230FS utilizes Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally activated element designed to open oPtionS: din rAil Kit AVAilABle. order PArt # 11604Kit unit AVAilABle witH Power on PluS FAilure led And Form C relAy ContACtS (SHA-1230FSr) in the event of overheating due to the abnormal over-voltage, limited current conditions. Features ■ 120 VAC, 30A service ■ Power On and Failure LED ■ FingerSafe connection ■ 50 kA/Mode and 100 kA/phase surge current protection ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ Summary alarm contacts general technical Specifications Part Number ■ 5 year warranty mounting Edco SHA-1230FS Maximum Operating Voltage 120 VAC Clamping Voltage 400 VAC Operating Current Hole (4 places) 3/16" Dia. 30A Peak Surge Current 50 kA/Mode, 100 kA/Phase, 150 kA Total Operating Frequency Plate 2.25" 3.25" 47–63 Hz EMI Attenuation 40 dB Normal/30 dB Common Mode SPD Technology MOVs w/L-C Filter Modes of Protection L-N, L-G, N-G Status Indication Power On & MOVs Functional Connection Type Recessed Terminal Screws Operating Temperature -40°C to +85°C Dimensions (Inches) 1.875H x 3.25W x 5.75L Weight 12 oz 5.25" 5.75" Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. installation diagram L Line Input From Source N GND 10 Line Load L L N N GND GND To Load or Equipment to Protect AC Power — Series Connected edco™ SHA-1260 120 VAC — Single Phase — 60A The Edco SHA-1260 is a 120 VAC Single Phase 2W+G, 60A surge suppressor/filter designed to shunt electrical type transients affecting the electrical distribution inside a traffic cabinet. The Edco SHA-1260 offers 50 kA per mode and 100 kA per phase of surge current protection. The Edco SHA-1260 utilizes Thermally-protected Metal Oxide Varistors (TMOVs) with an integrated thermally-activated element designed to open in the event of overheating due to the abnormal over-voltage, limited current conditions. Features ■ 120 VAC, 60A service ■ Thermally-protected Metal Oxide Varistors (TMOVs) ■ Phosphor bronze stud for substantial conductivity ■ 50 kA/mode and 100 kA/phase surge current protection ■ 5 year warranty ■ Power On and Failure LED installation general technical Specifications Part Number Edco SHA-1260 Maximum Operating Voltage 120 VAC Clamping Voltage 400 VAC Operating Current 60A Peak Surge Current 50 kA/Mode, 100 kA/Phase, 150 kA/Total Operating Frequency 47–63 Hz EMI Attenuation 40 dB typ SPD Technology MOVs w/L-C Filter Modes of Protection L Line Input From Source N GND Line Load L L N N GND To Load or Equipment to Protect GND L-N, L-G, N-G Status Indication Power On & MOVs Functional Connection Type Phosphor Bronze 1/4-20 Stud Operating Temperature -40°C to +85°C Dimensions (Inches) 3.5H x 4.75W x 7.25L Weight 2 lbs Caution: 1. This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. 2. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. mounting Hole (4 places) 3/16" Dia. Plate 3.5" 4.75" 6.75" 7.25" 11 AC Power — Series Connected islatrol™ inXt120nl000-1 AC Power Line Filter The Islatrol INXT120NL000-1 is a 120 VAC, 60A, EMI/RFI filter. The INXT is a series connected device designed to filter electrical type transients impinging on electrical distribution of a traffic control cabinet. Features ■ 60 amp series filter ■ Epoxy encapsulated ■ 50 dB attenuation (200 KHz to 75 MHz) ■ 5 year warranty ■ High impact thermoplastic enclosure general technical Specifications Part Number Islatrol INXT120NL000-1 Nominal Operating Voltage 120 VAC Operating Voltage Range 120V ±25% Operating Frequency Range 47–63 Hz Connection Type 1/4 -20 Studs Amperes Phase Configuration 60 Amperes Single Phase 2 Wire (Line and Neutral) Size Weight Maximum Continuous Operating Voltage (MCOV) Load Surge Current Rating 10 MSEC 1 SEC 5 SEC Transient Reduction/ Frequency Attenuation Packaging Operating Temperature Operating Humidity Operating Altitude Warranty 12 3.2" x 4.4" x 2.0" 2 lbs. 240 VAC 100 x Nominal 10 x Nominal 5 x Nominal 50 dB min (200 KHz to 75 MHz) Black, High Impact Plastic Case, Epoxy Encapsulated -40°C to +45°C Derate Linearly to 70% @ 70°C 0 to 95% Non-condensing -100m to 2000m 5 Years AC Power — Parallel Connected PowerSure™ emC-240B 120/240 VAC Heavy Duty (Parallel) The PowerSure EMC-240B surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically, the unit incorporates MOV and thermal fusing technology. The PowerSure EMC-240B is designed to be installed in parallel on standard single phase 120/240 VAC (3W + G) or single phase 120 VAC (2W + G) circuits. Features ■ Fast response time ■ Operational status indicators ■ 40 kA per phase capacity ■ ANSI/UL 1449 Third Edition Type 2 ■ Fused ■ 5 year warranty general technical Specifications mechanical Maximum Operating Voltage 120/240 VAC I Nominal (In) 2.8" 3 kA Operating Current 2.2" NA, Parallel Total Peak Surge Current 80 kA (8 x 20 µs) Operating Frequency 47–63 Hz EMI Attenuation (100 kHz to 100 MHz) > 40 dB SPD Technology 4.5" Metal Oxide Varistors (MOVs) Modes Of Protection Line-to-Line Line-to-Neutral Status Indication Power On & MOVs Functional Connection Type Wire Leads Operating Temperature 18" -40°C to +85°C Dimensions (Inches) 4.6H x 2.2W x 2.8L Weight 13.5 oz Certification ANSI/UL 1449 Third Edition, Type 2 Caution: Installation and service should be performed by qualified electricians only. Before installing EMC, remove all electrical power from circuits. Connect on load side of main breakers. Use two dedicated 30A circuit breakers. installation 120/240 VAC Service 120 VAC Service L1 L 120 V N EMC-240B 240 V N L2 120 V 240 V GND 120 V EMC-240B Black Black White Green Ground N Ground L 240 VAC Service L1 L2 240 V 240 V Black Black White Green L2 N L1 EMC-240B Black Black White Green L2 GND L1 13 2.8 2.2 AC Power — Parallel Connected PowerSure™ FAS-120AC Medium Duty 120 VAC — Single Phase The PowerSure FAS-120AC surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically the unit incorporates MOV and thermal fusing technology. This device is designed to be installed in parallel on standard single phase 120 VAC (L, N, G) circuits. Installation can be close-nipple up to a distribution panel/circuit or hardwired in parallel up to power supply input terminal screws. Be sure to dress leads as short as possible. Features ■ LED indicator ■ Compact size ■ Fast response time ■ Liquid tight conduit fitting ■ Thermal fuse ■ ANSI/UL 1449 Third Edition Type 2 ■ L-G, L-N, N-G protection ■ 5 year warranty general technical Specifications Part Number mounting PowerSure FAS-120AC Maximum Operating Voltage 120 VAC SPD Location Type Type 2 I-Nominal (In) 3 kA Operating Current Peak Surge Current NA 6.5 kA/Mode, 13 kA/Phase, 15.5 kA/Total Operating Frequency NA SPD Technology MOVs L-N, L-G, N-G Status Indication Power On & MOVs Functional Connection Type Wire Leads Operating Temperature Dimensions (Inches) 2.5H x 1.5W x 3.0L 4 oz ANSI/UL 1449 Third Edition, Type 2 Caution: This product should be installed and serviced by qualified service technicians or personnel only. Remove power before installation or service. Ø0.1860 -40°C to +85°C Weight Certification 1.5" 47–63 Hz EMI Attenuation Modes of Protection 14 2.5" 3" AC Power — Parallel Connected edco™ SPA-300 Medium Duty 120 VAC — Single Phase The Edco SPA-300 is designed to protect sensitive electronic equipment, such as traffic controllers, from high energy surges. The Edco SPA-300 incorporates MOV technology which clamps these surges before equipment damage occurs. The Edco SPA-300 is intended for use on bonded neutral to ground applications. Features ■ 40 kA surge protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Solid-state design general technical Specifications Part Number installation Edco SPA-300 Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Peak Surge Current 40 kA/Mode/Phase/Total Operating Frequency 47–63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type 1/4 -20 Stainless Steel Stud Operating Temperature -40°C to +85°C Dimensions (Inches) Hot 120 VAC Line Neutral 1.875H x 2.875W x 5.25L Weight Load SPA-300 Ground 1 lb Caution: This product should be installed and serviced by qualified service technicians or personnel only. mounting Remove power before installation or service. Hole 3/16" Plate 2.875" 4.875" 5.25" 15 AC Power — Parallel Connected edco™ SPA-100t AC Service Protection The Edco SPA-100T is a medium duty AC Service Arrester which is solid state in design. It is intended for equipment which is located in outdoor cabinets exposed to lightning transients. Application examples are railroad equipment, motor control cabinets, flasher cabinets, and traffic controllers. Features ■ Fast response time ■ Compact size ■ Solid-state design ■ 5 year warranty ■ Epoxy encapsulated installation general technical Specifications Part Number Edco SPA-100T Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Peak Surge Current 13 kA/Mode/Phase/Total Operating Frequency 47–63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type 10-32 Stainless Steel Stud Operating Temperature Dimensions (Inches) CB 120 VAC Input Line Hot 120 VAC SPA-100T Keep Leads Short and Straight Neutral Ground -40°C to +85°C 0.5H x 1.5W x 2.0L Weight 2 oz Caution: 1. Install SPA-100T on load side of breaker as shown. 2. Installation and service should be performed by qualified personnel only. mounting 3. Remove all electrical power from circuits before installing SPA-100T. 1" 1.5" 1.5" 2" 16 Load AC Power — Parallel Connected edco™ SHA-1201 120 VAC – Single Phase The Edco SHA-1201 is specifically designed for type 170 traffic controller cabinets that require power neutral to remain isolated from cabinet earth ground. Protection is provided both between phase-to-neutral, and neutralto-ground. If neutral is bonded to earth ground in the cabinet, the Edco SPA-100T unit should be considered as a cost-effective alternate to the Edco SHA-1201. Features ■ 53 kA surge protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Solid-state design general technical Specifications Part Number installation Edco SHA-1201 Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA, Parallel Peak Surge Current 40 kA/Mode, 40 kA/Phase, 53 kA/Total Operating Frequency Hot NA SPD Technology MOVs Modes of Protection L-N, N-G Status Indication NA Connection Type Black SHA-1201 47–63 Hz EMI Attenuation 120 VAC Neutral Earth Ground Grnd. Equipment White Chassis Ground Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 3L x 2W x 1H Weight 6 oz Caution: Installation and service should be performed by qualified technicians or service personnel only. mounting 2" 1.5" 3" 2.5" 3/16" Diameter Hole 17 low Voltage dC Power edco™ FAS-1 and FAS-2 Series One- and Two-Pair Signal Line Protection The Edco FAS-1 and Edco FAS-2 Series are multi-stage one- pair or two-pair surge suppressors designed for high-exposure applications. These products were specifically designed to meet multiple, low voltage, protection applications where operating currents can be as high as 2.5 amps. Features ■ Lightning protection for low voltage data/ signal lines ■ Common mode and differential mode protection ■ Multi stage protection ■ Automatic recovery ■ 5 year warranty general technical Specifications Part Number Edco FAS-1 and FAS-2 Series Maximum Operating Voltage 15, 24, 36, 52 VDC Clamping Voltage 18, 33, 43, 60 VDC Operating Current 2.5A Peak Surge Current < 0.1 dB at 10 MHz GDT, SAD, w/Series Inductor Operating Temperature Dimensions (Inches) 10–14 AWG -40°C to +85°C FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz <3 FAS-2 = 7 oz UL 497B Protected Equipment G RO UND I N G: DO NOT1Sdaisy intended for shield T CHchain O ICE:grounds. USE AC NOT P OWER termination. Install ground in accordance with all GRO UND applicable 2NDcodes. CH O ICE: USE B U I LDI NG 18 12 VDC Use FAS-1-033 HC (One-pair) FAS-2-033 HC (Two-pair) 24 VDC Use FAS-1-043 HC (One-pair) FAS-2-043 HC (Two-pair) 24 VAC Use 48V Systems Use *Not UL Listed Line. Terminal Block w/Compression Lugs Terminals Accept Up To 12 AWG FAS-1-018 HC (One-pair) FAS-2-018 HC (Two-pair) FAS-1-060 HC (One-pair)* FAS-2-060 HC (Two-pair)* Ground Lug Equip. SPD Technology Certification Unprotected Or Field Side 0 to 10 MHz Insertion Loss Weight ordering information 10 kA (8 x 20 µs) Frequency Range Connection Type installation Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. low Voltage dC Power edco™ PHC Series Two-Pair Signaling Circuit Protector (Modular) The Edco PHC Series is designed to protect two pairs of wires specifically where operating currents can be as high as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid implementing a staged complement of MOVs, copper wound inductors and Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms per pair. The Edco PHC modules plug into a base assembly (Edco PCB1B). The base assembly can be mounted to any flat surface and should be located as close as practical to the protected equipment. Terminal 1 and/or terminal 10 should be connected to Building-Approved Ground with 12- or 10-gauge solid wire. Features edCo PCB1B BASe Sold SePArAtely ■ Three-stage protection ■ Continuous current up to 5 amps ■ Differential protection ■ UL 497B listed ■ Common mode protection ■ Requires Edco PCB1B base ■ Plug-in module ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Automatic recovery ■ 5 year warranty ■ Fast response time general technical Specifications Part Number Edco PHC Series Maximum Operating Voltage 15, 20, 30, 36, 43, 60, 70, 150 VDC Operating Current 5A Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) 10 kA (8 x 20 µs) Odd Terminals Unprotected Pair 2 { Field Side Unprotected Pair 1 { Even Terminals 8 7 6 5 4 3 2 1 -40°C to +85°C 3.7H x 1.75W x 2.375L (PHC + PCB1B Base) Weight } P H C Protected Pair 2 Electronics Side 2.125" 2.4" } Protected Pair 1 Keying Pin < 0.1 dB at 10 MHz Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG Voltage Clamp 10 9 0 to 10 MHz MOV, SAD, w/Series Inductor How to Specify the Appropriate model PCB1B: 12, 18, 24, 36, 52, 70, 120 VDC Clamping Voltage ordering information terminal Assignments 1.0 Ground Terminal 1 or 10 to Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 0 1 5 15 Volts 0 2 0 20 Volts 0 3 0 30 Volts 0 4 3 43 Volts (For Horn, Bell, Strobes) 0 6 0 60 Volts S P 7 0 *100 Volts 1 3 0 R M S *150 Volts (For 120V Signal Lines) *Not UL Listed dimensions 8 oz Certification UL 497B Applications Part number 24V Horn, Strobe, Bell 70V Speaker Lines PHC-043 & PCB1B PHC-SP70 & PCB1B 19 input Files/loop detection edco™ SrA-6lC Series Vehicle Loop Detection The Edco SRA-6LC Series are three terminal devices, two of which are connected across the signal inputs of the detector for differential mode protection, and the third is grounded to protect against common mode damage. This unit addresses over-voltage transients on both Common and Differential modes with state-of-the-art silicon breakover devices. The Edco SRA-6LC Series is intended for all popular makes of loop detectors presently on the market. Features ■ Differential and common mode protection ■ Epoxy encapsulated ■ Fast response time ■ 5 year warranty ■ Easy installation ■ Compatible with digital detectors general technical Specifications installation ordering information Part Number General: Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Connect one of the leads to each loop. The common (either the bolt, green wire or center clip) connection must be connected to earth ground. Best performance is obtained by shortening the leads as much as possible, and providing the lowest impedance to ground. One Edco SRA-6LC is used on each loop detector circuit to be protected. SRA-6LC Edco SRA-6LC Maximum Operating Voltage 75 VDC Clamping Voltage 130 VDC Operating Current NA Peak Surge Current 250A SPD Technology Silicon Breakover Device Operating Temperature Weight Dimensions: SRA-6LC SRA-6LC w/Leads Mounting: SRA-6LCA-716 SRA-6LCA-916 SRA-6LCB SRA-6LCBLL -40°C to +85°C 3 oz 1.2" Square Cube 1.2" Square Cube 7/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing 9/16" Terminal Strip Spacing The Edco SRA-6LCA slips under the equipmentside screws of the terminal strip. (See Drawing A) The protector ground is the center spade of the 3 spade terminations. The terminal strip must jumper this corresponding position to ground. Protectors can be mounted consecutively along the terminal strip. drawing A Edc o Edc o The Edco SRA-6LCB slips under the equipmentside screws of the terminal strip. The protector ground wire must be bonded in a short, direct manner to the cabinet power ground. Protectors can be mounted consecutively along the terminal strip. The Edco SRA-6LC has mounting brackets available for installing multiple units in the controller cabinet. The brackets are capable of mounting four or eight devices in-line. 20 Cube, 2 leads + stud SRA-6LC w/Leads Cube, 3 leads/no stud SRA-6LCA-716 3 Spaded Term. Block 7/16 Spacing SRA-6LCA-916 3 Spaded Term. Block 9/16 Spacing SRA-6LCB 2 Spaded Term. Block w/3.5" Gnd. Wire SRA-6LCBLL 2 Spaded Term. Block w/11" Gnd. Wire Caution: Installation and service should be performed by qualified technicians or service personnel. input Files/loop detection edco™ SrA16C-1 Vehicle Loop Detection The Edco SRA16C-1 is a three terminal device, two of which are connected across the signal inputs of the detector for differential mode protection, and the third is grounded to protect against common mode damage. Differential mode surges (induced voltage across the loop detector input terminals) are instantly clamped by a semiconductor array. The array is designed to appear as very low capacitance to the detector. Common mode surges (induced voltage between the loop leads & ground) are handled by a rugged three-element gas discharge tube which operates (fires) at 90 VDC and thereafter clamps the two loop leads to 30 volts in respect to ground. This design eliminates any ground noise from entering the loop detector and being amplified. The Edco SRA16C-1 is intended for all current detector models on the market. Features ■ Rugged gas tube protection ■ Compatible with digital detectors ■ 5 year warranty general technical Specifications installation Part Number Edco SRA16C-1 Maximum Operating Voltage 75 VDC Clamping Voltage 90 VDC Operating Current NA Peak Surge Current 10 kA SPD Technology GDT Connection Type Leads Operating Temperature -40°C to +85°C Dimensions 1" Sq., Ht. 2" Max. Mounting No. 10 - 32 x 3/8" Stud Weight 3 oz Mounting brackets are available for installing multiple units in the controller cabinet. The brackets are capable of mounting four or eight devices in-line. One Edco SRA16C-1 is used for each loop detector to be protected. Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Connect one of the flexible leads to each end of the loop. The common (bolt) connection on each Edco SRA16C-1 must be connected to earth ground. Best performance is obtained by (1) shortening the flexible leads as much as possible, and (2) providing the lowest possible impedance to ground. NOTE: The Edco SRA16C-1 w/Leads (special order) is installed very similar to the standard unit except the common (bolt) is replaced with a green wire. edco™ mrA-6lC-6 Vehicle Loop Detection Protector The Edco MRA-6LC-6 is a modular device utilizing solid state silicon foldover technology. The Edco MRA-6LC-6 is designed for any traffic controller cabinet equipped with 6 position, 5.08 mm spacing sockets wired in-line with load relay outputs. Features ■ Modular design ■ Differential and common mode protection ■ Fits 6 position, 5.08 mm spacing sockets ■ 5 year warranty ■ Designed for digital detector general technical Specifications Part Number Maximum Operating Voltage Edco MRA-6LC-6 Clamping Voltage 130 VDC Operating Current NA Peak Surge Current SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight 2 oz 75 VDC 250A Silicon Breakover Device 6 Position 5.08 mm Euroblock -40°C to +85°C 2H x 0.7W x 1.5L installation One Edco MRA-6LC-6 is used for each two loop detectors to be protected. Units are installed as close as practical to the point where the detector loop wires enter the controller cabinet. Caution: Installation and service should be performed by qualified technicians or service personnel. 21 output Files edco™ SPA-303 120 VAC Load Relay The Edco SPA-303 is a three circuit protective device intended for use on traffic control load relay outputs. The protector is furnished with three leads and a ground stud. Features ■ 5 year warranty ■ Convenient mounting/grounding stud ■ Compact size mounting general technical Specifications Part Number Edco SPA-303 Maximum Operating Voltage 120 VAC Clamping Voltage 395 VAC Operating Current NA Total Peak Surge Current 39 kA Operating Frequency 47–63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Connection Type Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 1.5" SPA-303 5/8" Caution: To prevent shock hazard, this product should never be ungrounded (bolt disconnected from ground) when power is applied to leads. 1" 1.5H x 1W x 2.125L Weight 5 oz 2.125" edco™ mPA-303 Series Modular Output File Protector The Edco MPA-303 Series is a modular device intended for use on traffic control load relay outputs. The Edco MPA-303-9 unit will protect six output circuits. The Edco MPA-303-6 unit will protect four output circuits. The Edco MPA-303-9 is designed for any traffic controller cabinet equipped with 9 position, 5.08 mm spacing sockets wired in line with load relay outputs. The Edco MPA-303-6 is designed for 6 position, 5.08 mm spacing sockets. Features ■ Modular design for 6 and 4 output circuits ■ 5 year warranty ■ Fits 6 and 9 position, 5.08 mm spacing sockets general technical Specifications Part Number Connection Type 120 VAC Operating Temperature Clamping Voltage 340 VAC Dimensions (Inches, Module only) Operating Current Total Peak Surge Current Operating Frequency 22 Edco MPA-303 Series Maximum Operating Voltage NA Weight 6 or 9 position 5.08 mm Euroblock -40°C to +85°C 2.0H x 0.7W x 2.0L 2 oz 26k (6 pos), 39k (9 pos) 47–63 Hz EMI Attenuation NA SPD Technology MOVs Status Indication NA Caution: This product could become excessively hot and rupture in the rare event of power line conditions or surge that exceed its rated operating specification. Appropriate precautions should be exercised. High voltages are present on electrical termination. Unit should be serviced by qualified personnel only. Communication lines edco™ PC642 Series Zone/Loop/Data The Edco PC642 Series surge suppressor is a two-pair (four-wire) module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. The Edco PC642 card edge module is gold plated, double-sided, and is designed to mate with the Edco PCB1B gold-plated female terminal connector. When snapped together, the data circuits “pass thru” the protector in a serial fashion from the four “Field Side” terminals to the four “Electronics Side” terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building-Approved Ground per Edco Technical Bulletin # 2015. edCo PCB1B BASe Sold SePArAtely oPtion: din rAil Kit AVAilABle order PArt # 11604Kit-PC Features general technical Specifications Part Number ■ Three-stage hybrid protection ■ Fast response time ■ Sneak/fault current protection ■ Requires Edco PCB1B base ■ Resettable fusing — PTCs ■ Low capacitance option ■ PC642PTU (Pass Thru Unit) available for troubleshooting ■ Plug-in module ■ 5 year warranty terminal Assignments Edco PC642 Series PCB1B: Maximum Operating Voltage 5, 12, 18, 24, 30, 36, Odd Terminals 43, 52, 180 VDC Clamping Voltage Operating Current Peak Surge Current Frequency Range Insertion Loss 8, 15, 20, 30, 36, 43, 50, 60, 200 VDC Terminal Block w/Compression Lugs Terminals Accept Up To 10 AWG Weight Certification { Unprotected Pair 1 10 9 8 7 6 5 4 3 2 1 } } Ground Terminal 1 or 10 to Building-Approved Ground VOLTAGE CLAMP 8 Volts 15 Volts 20 Volts 30 Volts 36 Volts 43 Volts 50 Volts 60 Volts *200 Volts •Not UL Listed 0 0 0 0 0 0 0 0 2 0 1 2 3 3 4 5 6 0 8 5 0 0 6 3 0 0 0 D X LC no suffix stage 2 clamp each line-to-ground stage 2 clamp line-to-line only recommended for traffic comm. lines stage 2 clamp line-to-line and each line to ground low capacitance option stage 2 clamp line-to-line and each line to ground use “d” Suffix for traffic Communication lines DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. ordering information Application: PC642 RS485, RS422: E-NET, 10 BASE T: UL 497B PC642C-008LC & PCB1B RS423, Token Ring: PC642C-008LC & PCB1B RS232: 1 oz Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 150 milliamperes. Protected Pair 1 Keying Pin -40°C to +85°C 2H x 1W x 2.5L (PC642 + PCB1B Base) Protected Pair 2 Electronics Side 2.125" 2.4" 1.0 0 to 20 MHz Connection Type Dimensions (Inches) Field Side PC642C Even Terminals 10 kA (8 x 20 µs) GDT, SAD, w/Series PTC Operating Temperature { Unprotected Pair 2 0.15A < 0.1 dB at 20 MHz SPD Technology How to Specify the Appropriate model 4–20ma: PC642C-020 & PCB1B PC642C-030LC & PCB1B PC642C-036 & PCB1B PCB1B 23 Communication lines edco™ SrA64 Series Single Pair Data/Signal The Edco SRA64 Series surge suppressor is a single pair cube implementing three-stage hybrid technology. This cube addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when over currents exceed safe levels. A normal state resumes when over currents are removed. The ability to self restore in this manner significantly increases suppressor performance and survivability. The standard Edco SRA64 second stage clamps are placed from each signal lineto-ground. In certain cases, where ground potentials vary from site-to-site, a line-to-line only second stage clamp may be preferred. This variation is specified by a suffix “D” on the part number. In other cases, line-to-line and line-to-ground second stage clamps may be preferred. This variation uses an “X” suffix on the part number. A variety of clamping voltages are available as standard. Reference the “How To Specify The Appropriate Model” section to ensure that a complete part number description is obtained. Features ■ Lightning protection for balanced low voltage signal lines ■ Common mode protection ■ Multi-stage protection ■ Fast response time ■ Sneak/fault current protection ■ Flame retardant epoxy encapsulated ■ Differential mode protection ■ 5 year warranty general technical Specifications Part Number How to Specify the Appropriate model 10kA (8 x 20 µs) Response Time <1 Nanosecond Resistance Temperature Weight Dimensions Mounting Stud (standard) SRA64C - Edco SRA64 Series Total Peak Surge Current Clamping Voltage ■ Automatic recovery 8, 12, 15, 20, 30, 36, 43, 50, 60, or 200 VDC 5Ω (typical) -40°C to+85°C 2 oz 1.15" Cube No.10-32 x 1/2" VOLTAGE CLAMP 8 Volts 12 Volts 15 Volts 20 Volts 30 Volts 36 Volts 43 Volts 50 Volts 60 Volts *200 Volts 0 0 0 0 0 0 0 0 0 2 0 1 1 2 3 3 4 5 6 0 8 2 5 0 0 6 3 0 0 0 D no suffix stage 2 clamp each line-to-ground stage 2 clamp line-to-line only X stage 2 clamp line-to-line and each line to ground *Not UL Listed Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal lines capable of continuously supplying more than 150 milliamperes. wiring Assignments Black White Field Side (Outside Plant) Electronics Side (Equipment) Black/Red 24 White/Red Communication lines edco™ SPA-60B Series 120 VAC Interconnect Signal The Edco SPA-60B is an economical method of protecting circuitry associated with 120 VAC interconnect signal lines commonly used in traffic control systems. In the presence of normal interconnect line voltage and frequency (60 Hz), the Edco SPA-60B possesses the ideal characteristics of high impedance across the protector and no impedance in series with the line. In the presence of transients, the protector appears as very low impedance, thereby shunting the surge to ground. The product is offered in four variations. The Edco SPA-60BL protects one circuit and is furnished with two leads. The Edco SPA-60BL-2 is identical except it protects two circuits and is furnished with three leads.The Edco SPA-60BS protects one circuit and consists of one lead and a stud (also used for mounting). The Edco SPA-60BS-2 is identical except it protects two circuits and consists of two leads and a stud. Refer to ordering information below. Features ■ Rugged gas tube protection ■ Various models available ■ Fast response time ■ 5 year warranty ■ Compact size general technical Specifications Part Number installation Edco SPA-60B Series Maximum Operating Voltage 120 VAC Clamping Voltage 350 VAC Operating Current Total Peak Surge Current Operating Frequency NA 10 kA 47-63 Hz EMI Attenuation NA SPD Technology GDT Status Indication NA Connection Type Leads Operating Temperature -40°C to +85°C Size: BL Types BS Types 1.50" x .5" x .8" 1" cube Mounting Studs 10:32 x 3/8" SS Weight Stud mounting unit: Connect black lead to interconnect signal line near entry point into cabinet. Shorten lead as much as possible. Bolt unit to clean metal surface bonded to power/earth ground (cabinet in most cases). lead Supported unit: Shorten leads. Connect between interconnect signal line and power/ earth ground. ordering information SPA-60B L Leads One Circuit (blank) S Studs Two Circuits 2 2 oz Note: This product is intended for use on 120 VAC interconnect lines. Do NOT use on AC service or power lines. 25 Video edco™ CX Series CCTV & Data Applications/Coax The Edco CX Series Surge Protective Devices (SPDs) implement three-stage hybrid technology. The SPDs address over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and fault currents, are mitigated with solid-state resettable fuses —PTCs. The Edco CX Series SPDs are designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 kA of surge current capability. The Edco CX06-MI model has an isolated ground and is recommended for use at the camera end. oPtion: din rAil Kit AVAilABle order PArt # 11604Kit-CX Features ■ Sneak/fault current protection ■ CX06-MI has an isolated ground ■ Low insertion loss ■ 5 year warranty ■ Shielded case general technical Specifications ordering information Maximum Operating Voltage 5 VDC Connection Type Clamping Voltage 6 VDC Operating Temperature 0.17A Dimensions (Inches) Operating Current Peak Surge Current Frequency Range Insertion Loss SPD Technology 20 kA (8 x 20 µs) 0 to 20 MHz < 1 dB at 20 MHz GDT, SAD, w/Series PTC Weight Certification BNC, 50/75 Ohms -40°C to +85°C M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L SBL = 1.7H x 1.4W x 2.8L M = 2.3 oz MI = 3 oz UL 497B CX06-mi-SBl installation 26 CX06-M CX06-MI CX06-MI-SBL Head End Camera End • Other configurations available — please consult factory Video edco™ HVCP-48 Video Control Power Protection The Edco HVCP-48 is a hybrid surge protection product featuring DC power, data and video protection in one package. Each separate circuit is capable of handling high-current impulses while tightly clamping transients and allowing critical power and data to be transmitted. Features ■ Three separate hybrid circuits ■ Ultra low capacitance, low signal loss ■ Balanced transition circuit ■ Rugged gas tube protection ■ Shielded case ■ 5 year warranty general technical Specifications Operating Voltage Maximum Operating Current Clamping Voltage Total Peak Surge Current Rating SPD Technology High Speed Data Protection (SDIO) Clamping Voltage Total Peak Surge Current Rating SPD Technology Video Protection Clamping Voltage Total Peak Surge Current Rating SPD Technology installation 48 VDC 1 Amp 70 VDC 10 kA GDT, SAD, Series Element Operating Temperature Operating Humidity Environmental 5 - + Gnd. + 4 3 2 1 Field HVCP-48 Chassis Ground 2V 10 kA GDT, SAD, Series Element 12 AWG, 36.0" Long Mounting 6 VS 10 kA Ground Wire Weight + GDT, SAD, Series Element 6 Position 5.08 mm Header & Plug (28 -12 AWG) Material - Video 15V Connections Dimensions (Inches) SDIO 3.3 L x 3.3 W x 1.35 H 6 5 4 3 - + - + SDIO Video 2 1 Gnd. + Protected VS High Impact Plastic 12 oz Flange Mounted, 3.75" Mtg. Hole Distance, (.188 dia.) (2x) DIN Rail Mounting (Optional) -40°C to +74°C 0% to 95% Non-condensing RoHS Compliant 27 modem edco™ FAS-tel-dot RJ Connection Telephone Protection For Traffic Cabinets The Edco FAS-TEL-DOT is a single pair telephone protector that implements an advanced three-stage hybrid design. This unit addresses over-voltage transients with gas discharge tubes (GDT) and silicon breakover devices. Additionally, sneak and fault currents are mitigated with PTC technology, which consists of solid state resettable fuses. The Edco FAS-TEL-DOT is specifically designed for more rugged applications such as traffic cabinets. Features ■ Three-stage hybrid design ■ Fast response time ■ Rugged gas tube protection ■ 5 year warranty ■ Sneak/fault current protection installation general technical Specifications Part Number Edco FAS-TEL-DOT Maximum Operating Voltage 220 VDC Clamping Voltage 270 VDC Operating Current 0.15A Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight 10 kA 0 to 20 MHz FAS-TEL-DOT To Phone or Computer Protected Side < 0.1 dB at 20 MHz GDT, Silicon Breakover w/PTC R1 T1 Term Block, Comp. Lug IN/RJ OUT -40°C to +85°C 1H x 2W x 2L TELCO R 2 oz Unprotected Side Field 28 T Building Approved Ground data/Signal line edco™ rJA-rJd Series RJ-45 Telephone/Data The Edco RJA and Edco RJD Series are four pair telephone/data-line protectors that implement advanced, two stage, hybrid design. These units address overvoltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology, which consists of solid state resettable fuses. The Edco RJA and Edco RJD Series incorporate RJ-45 female jacks in and out. The Edco RJA voltage clamp is set for C.O. Trunks and Analog Telephone Extensions (with ring in voltage), and the Edco RJD voltage clamp is set for Digital Extensions (no ring in voltage). Features ■ <1 nanosecond response time ■ Solid-state resettable fuses-PTCs ■ Silicon breakover technology ■ Low capacitance ■ Line-to-line protection general technical Specifications Part Number ■ Tip and ring to ground protection ■ CAN/CSA C22.2, No. 226-92 compliant ■ UL 497A listed ■ 4 pair protection ■ 5 year warranty installation ordering information Edco RJA-RJD Series RJA-45 Analog Phone Maximum Operating Voltage 48, 220 VDC RJD-45 Digital Phone Clamping Voltage 55, 280 VDC Operating Current Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight Certifications 0.15A 200 A (10 x 1000 µs) 0 to 50 MHz < 0.1 dB at 50 MHz Silicon Breakover Devices w/Series PTC RJ-45 Jacks -40°C to +85°C 1.0H x 2.5W x 4.25L 3 oz UL 497A, CUL Caution: The Edco RJA and Edco RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector. 29 data/Signal line edco™ SrS-Biu-15 NEMA TS-2 Port 1 Protector The Edco SRS-BIU-15 is a 15 pin surge suppressor used for protection of all devices on Port 1 Synchronous Data Link Control (SDLC). Features ■ All other pins provide pass thru connection ■ Pins surge protected are 1, 3, 5, 7, 9, 11, 13 and 15 ■ Independent pass thru pins are 12 and 14 ■ 1500 watts of protection in each direction (positive or negative impulse) ■ 5 year warranty ■ Pass thru pins are 2, 4, 6 and 8 connected together ■ External grounding connected to pin 12 general technical Specifications Pin out Maximum Operating Voltage 5 VDC Pin Function Clamping Voltage 8 VDC 1 Rx Data + Operating Current 1.5A 2 Logic Ground 47A (10 x1000 µs) 3 Rx Clock + Logic Ground Peak Surge Current Frequency Range Insertion Loss SPD Technology Connection Type Operating Temperature Dimensions (Inches) Weight 30 ■ 8 high-speed, low-capacitance, surgeprotected pins – allows high speed data transfer 0 to 20 MHz 4 < 0.1 dB at 20 MHz 5 Tx Data + SAD 6 Logic Ground DB-15 7 Tx Clock + -40°C to +85°C 8 Logic Ground 1.5H x 0.625W x 2.25L 9 Rx Data - 1.25 oz 10 Port 1 Disable (0 VDC = disable) 11 Rx Clock - 12 Earth Ground 13 Tx Data - 14 Reserved 15 Tx Clock - Highway lighting edco™ SHA Series Highway Lighting Protection The Edco SHA Series provides surge protection for highway lighting/street pole applications. The suppressor is encapsulated in a weatherproof enclosure that is installed right inside the pole. The SHA Series is available in 120V, 240V, 277V and 480V Single Phase models. In addition, optional Low Capacitance (LC) and Both Black (BB) leads models are offered. Features ■ Weatherproof ■ Solid-state design ■ No follow current ■ Various options available ■ Line-to-ground protection ■ 5 year warranty ■ Neutral-to-ground protection general technical Specifications Part Number installation Edco SHA-Series Maximum Operating Voltage 120, 240, 277, 480 VAC Clamping Voltage 395, 710, 850, 1500 VAC Operating Current NA Total Peak Surge Current Black L1 IN To Source 39 kA Operating Frequency Green 47–63 Hz EMI Attenuation NA SPD Technology MOVs Modes of Protection L-G, N-G Status Indication NA Connection Type Leads Operating Temperature -40°C to +85°C Dimensions (Inches) 0.8H x 2.875W x 5.3L Weight 1 lb L1 Out Black Edco SHA Series White L2 IN gauge Color Connection 22" 6 Green Ground 12" 10 Black L-1 (Hot) 12" 10 White L-2 (Neutral or Hot) L2 Out White Caution: Installation and service of this product should be performed by qualified personnel only. models SHA-1203, SHA-2403, SHA-4803 leads length To Ballast SHA-2773 (available upon request) SHA-4803BB (Both leads Black) SHA-_ _ _ _LC (Low Capacitance option) Standard Special 31 Highway lighting edco™ SHAS Series Highway Lighting Protection The Edco SHAS Series Highway Lighting Protector is a smaller version of the popular Edco SHA Series. It easily fits into a 3" x 5" hand hole and incorporates the use of TMOVs (MOVs with a thermal cutoff) and an LED. Should the unit’s TMOVs degrade as a result of either a large surge or over time due to multiple surges, the LED will go out. This will enable the maintenance personnel to easily identify if the protection is lost and the unit needs replacing. The Edco SHAS Series also has about 30% less capacitance, thus eliminating the need to require a low capacitance version. Features ■ Neutral-to-ground protection (120V model) ■ Weatherproof ■ No follow current ■ LED surge “OK” indicator ■ Line-to-ground protection ■ 5 year warranty general technical Specifications model installation SHAS-120 SHAS-240 SHAS-277 SHAS-480 36 kA 36 kA 36 kA 36 kA <25 <25 <25 Clamp Voltage; @ 1 ma (V peak) 240 @ 200 Amps 395 430 710 430 710 Max. Allowable Voltage (AC RMS) 275 275 550 Total Peak Surge Current (8 x 20 µs) Response Time (nanoseconds) 150 <25 B l a c k B l a c k 910 1500 L1 L2 Current Drain (microamps) 120 175 175 130 Insulation to Ground (volts) >600 >600 >600 >600 120 VAC 240 VAC 277 VAC 480 VAC Lighting Application Dimensions lead length Load 2" 2.5" 1.5"H x 2"L x 2"W wiring gauge Color Connection 2" Line L1 L2 B l a c k B l a c k ordering information 22" 12 Green Ground model 12" 12 Black L-1 (hot) SHAS-120 12" 12 Black L-2 (Neutral or Hot) SHAS-240 SHAS-277 SHAS-480 32 1.5" Green To Ground notes 33 Headquarters Surge Protection 100 Emerson Parkway Binghamton, NY 13905 T: 607-721-8840 T: 800-288-6169 F: 607-722-8713 E: contactsurge@emerson.com emerson network Power. The global leader in enabling Business-Critical ContinuityTM. emersonnetworkPower.com/surge AC Power Connectivity Embedded Computing Embedded Power Outside Plant Power Switching & Controls Racks and Integrated Cabinets Services DC Power Monitoring Precision Cooling Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2010 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. SL-50100 Rev.1 8/10 Printed in USA