AC AMMETER / Moving Iron AC VOLTMETER / Moving Iron DC

advertisement
www.acorp.co.za
AC AMMETER / Moving Iron
Model AEC
Accuracy Class: 1.5%
Size: 48 : 72 : 96mm2
Standard overscale : 100%. For CT connected
meters, specify CT Ratio when ordering.
Type AEC 48
1 or 5A CT Connected
193-00
Type AEC 72/96
1 or 5A CT Connected
163-00
Type AEC 144
1 or 5A CT Connected
471-00
Type AEC 48
5 : 10 : 15 : 20 : 25 : 30 : 40 A Direct
193-00
Type AEC 72/96
5 : 10 : 15 : 20 : 25 : 30 : 40 : 50 : 60 : 75 : 80 : 100 A Direct
163-00
AC VOLTMETER / Moving Iron
Model VEF
Accuracy Class: 1.5%
Size: 48 : 72 : 96mm2
Type VEF 48
150 : 250 : 300 : 400 : 500 : 600V [specify voltage when ordering]
211-00
Type VEF 72/96 150 : 250 : 300 : 400 : 500 : 600V [specify voltage when ordering]
176-00
Type VEF 144
150 : 250 : 300 : 400 : 500 : 600V [specify voltage when ordering]
592-00
Type VEF PT
Conn. 72/96
Please specify range, scale & PT ratio when ordering
EG. Scaled 0 - 15Kv for PT Ratio 11Kv = 110V R/L at 11Kv
211-00
DC AMMETER / Moving Coil
Model ABC
Accuracy Class: 1.5%
Size: 48 : 72 : 96mm2
For Non-standard Range & Scale
Add R30-00 to price below
Type ABC 48
50mv Input - specify range & scale when ordering
344-00
Type ABC 72/96
50mv Input - specify range & scale when ordering
314-00
Type ABC 144
50mv Input - specify range & scale when ordering
593-00
Type ABC 48
Dc Amps Direct Max 10A DC (there after use shunt)
344-00
Type ABC 72/96
Dc Amps Direct Max 30A DC (there after use shunt)
344-00
DC VOLTMETER / Moving Coil
Model VBC
Accuracy Class: 1.5%
Size: 48 : 72 : 96mm2
For Non-standard Range & Scale
Add R30-00 to price below
Type VBC 48
1ma to 600V direct connected [specify voltage when ordering]
344-00
Type VBC 72/96
1ma to 600V direct connected [specify voltage when ordering]
344-00
Type VBC 144
1ma to 600V direct connected [specify voltage when ordering]
593-00
Type VBC 48
0/4 - 20 MA scale TBA
344-00
Type VBC 72/96
0/4 - 20 MA scale TBA
344-00
Page 1
www.acorp.co.za
Maximum Demand Ammeter
Model MD [2 VA]
Standard: 20% Overscale
15 minute Bi-metal movement 2 needle
These meters measure the max mean
load in 15 Minutes, as indicated by
the red drag pointer. This red pointer
can be reset to zero position.
Accuracy Class: 3.0%
Specifications: 15 min / 5A
Size: 72 : 96mm2
Overload Specs: Standard Instr : 5 × Full load for 5 sec.
With SAT CT: 10 × Full load for 3 sec.
: 10 × Full load for 1 sec.
: 20 × Full load for 1 sec.
Type MD 96
5 Amp CT connected
Maximum demand
2 needle
423-00
Type MD + SAT 96
5 Amp SAT CT
Maximum demand
2 needle
484-00
Maximum Demand Ammeter + Instantaneous
Model MDI [2.5 VA]
Standard: 20% Overscale on Bi-metal
: 100% Overscale on Instantaneous
15 minute Bi-metal movement 2 needle
Accuracy Class: Bimetal movement 3.0% These meters measure the max mean load
in 15 Minutes, as indicated by the red drag
: Moving iron 1.5%
pointer. This red pointer can be reset to zero.
In addition to this it also shows the instantaSpecifications: 15 min / 5A
neous reading of the actual load.
Size: 72 : 96mm2
Overload Specs: Standard Instr : 5 × Full load for 5 sec.
With SAT CT: 10 × Full load for 3 sec.
Type MDI 72/96
: 10 × Full load for 1 sec.
: 20 × Full load for 1 sec.
5/1A Amp CT connected Maximum demand & Inst 3 Needle
544-00
NB: 72/1A are not available
Type MDI + SAT 96 5/1A Amp SAT CT
Maximum demand & Inst 3 Needle
617-00
Frequency Meter Pointer
Model FMP
Accuracy Class: 1.0%
Specifications: 45 - 55 Hz
Size: 48 : 72 : 96mm2
FOR 525V ADD R30.00
Type FMP 48
110V : 220V
[Specify voltage when ordering]
459-00
Type FMP 72
110V : 220V : 380V
[Specify voltage when ordering]
459-00
Type FMP 96
110V : 220V : 380V
[Specify voltage when ordering]
459-00
Frequency Meter Reed
Model FMR
Accuracy Class: 1.0%
Specifications: 45 - 55 Hz
Size: 72 : 96mm2
FOR 525V ADD R30.00
Type FMR 72
110V : 220V : 380V
[Specify voltage when ordering]
556-00
Type FMR 96
110V : 220V : 380V
[Specify voltage when ordering]
556-00
Page 2
www.acorp.co.za
240 Degree Instruments [AC &DC]
Model ABC :DC Moving Coil
Model ABCR :AC Input with rectified moving coil
Accuracy Class: 1.5%
Specifications: Model ABC
:1.1VA
: Model ABCR :3.0VA
Specify range & scale when ordering
Size: 48 : 72 : 96 : 144mm2
Type ABC 48/240
Standard mV & mA Ranges DC
P.O.A.
Type ABCR 48/240
Standard V & A Ranges AC
P.O.A.
Type ABC 72/96/240
Standard mV & mA Ranges DC
1137-00
Type ABCR 72/96/240
Standard V & A Ranges AC
1137-00
Type ABC 144/240
Standard mV & mA Ranges DC
P.O.A.
Power Factor Meter
Model RPF For single & 3 Phase 3 Wire
(1 × CT Balanced Load) Applications
Accuracy Class: 1.5%
Specifications: 40 - 60 Hz
Size: 96mm2
Graduation : 0.5 Lead - 1 - 0.5 Lag
Specify Inputs Volts & Amps when ordering.
Type RPF 96 / 1 Ph
220V / 1 or 5A
1294-00
Type RPF 96/ 3 Ph
110 : 380 525V / 1 or 5A
1294-00
Synchronoscope
Model RSI
Accuracy Class:
Specifications:
Max. Working Time:
Size:
Type RSI 96
1.5%
50 - 60Hz
15 Min.
96mm2
These meters are used for Phase
comparison in 1 or 3 Phase circuits
110 : 220 : 380 : 525V
[Specify voltage when ordering]
871-00
Phase Sequence Indicator
Model FMR
Accuracy Class:
Operating Voltage:
Max. Testing Time:
Size:
Frequency:
Type RS 96
These meters are used for testing
the correct phase sequence in 3
phase systems within the specified
voltage range by holding down the
button on the front face of the meter.
1.5%
150 - 600VAC
5 Min.
72 & 96mm2
50 - 400 Hz
within range of 150 - 600VAC
726-00
Panel Meter Protection Covers / Blanking Plates
IP 65
48mm
280-00
IP 65
72mm
280-00
IP 65
96mm
280-00
72mm Blanking Plate Black Plastic
163-00
96mm Blanking Plate Black Plastic
163-00
Page 3
www.acorp.co.za
Running Hour Counters
Model RH
These elapsed Time Meters monitor
“On / Off” time of plant and equipment.
The time is measured in increments of
0.01Hrs up to 99999.99Hrs, after which
time the meter resets to zero.
Accuracy Class: 1.0%
Frequency: 50Hz
Size: 48 : 72 : 96mm2
7 Digits: 99999.99 Hours
Type RH 48
24 : 110 : 220 : 380VAC [HM 2 Din Mount or HM1 Panel mount]
157-00
Type RH 48
10 - 50VDC
260-00
Type RH 72
110 : 220 : 380VAC [Specify voltage when ordering]
290-00
Type RH 96
110 : 220 : 380VAC [Specify voltage when ordering]
290-00
Frame 72
72mm Frame 48 - 72mm
60-00
[Within this range]
Selector Switches
Contact Rating : 16A / 380 VAC
ISO 9001 : 2000
Ammeter Selector Switch
Model CA 34 / 4 Position
For 3 Phase 4 wire system using 3 Current Transformers
Voltmeter Selector Switch
Model CV 34 / 4 and 7 Position
For 3 Phase 4 wire system using 3PT’s or Direct Connected
Ammeter Model CA 34
4 Position : Off / Red / White / Blue
204-00
Voltmeter Model CV 34
7 Position : Off / Phase / Phase & Phase / Neutral
204-00
Voltmeter Model CV 33
4 Position : Off / Red / White / Blue
204-00
Page 4
www.acorp.co.za
DC Round Back Meters (Moving Coil)
Model JL - 60
Accuracy Class: 2.5%
Size: 60 × 60 mm2
Cut Out: 52mm Round
Type VDC JL - 60
15 : 30 : 50 : 100VDC
[Specify when ordering]
139-00
Type ADC JL - 60
2.5 : 5 : 15ADC DIR
[Specify when ordering]
139-00
Type MV JL - 60
50mV ADC
[Specify when ordering]
139-00
Dimensions:
Size
A
B
C
D
E
F
G
H
M
For
Hole
JL 60
60
60
24
11
9.5
11
52
24
3
53
Page 5
www.acorp.co.za
Panel Meters General Specifications
Conform to following standards
Insulation
Insulation reference voltage : 0.6KV
Ce185 : EN60051 : IEC414 : VDEO410 :
UNE21318 : DIN43780 : IEC51 : S.A.B.S
Working Temperature
Castings
-25 deg. C to +55 Deg. C
Material: ABS & P.C. (Anti-Fire)
Protection degree for cases: Ip52
Working Voltage
All instruments are manufactured within the
1.5% or 2.5% specification, unless otherwise
specified in the Data Sheet.
Vibration Range
660 Volt
Accuracy Class
+/- 0.25 amplitude at 50 / 60Hz
All panel meters are fitted
with slide in scales and
protective terminal covers.
Mounting Position
Standard: Verticle
Non standard to be specified when ordering.
Instruments Technical Characteristics Identification Signs
Negative Terminal
1.0 : 1.5 : 2.5
Class Index
DC
AC
DC & AC Rectified
2
KV
Test Voltage
Verticle Mounting Position
50°
Inclined Mounting [ For example 50 Deg.]
Moving coil movement for DC instruments
Moving iron movement for AC instruments
Bi-metal movement for maximum demand indicators
Vibrating reed frequency meter
Outline & Cut-out Dimensions (mm)
Outline Size (mm)
Panel Cut-Out (mm)
48 × 48
45 × 45
72 × 72
68 × 68
96 × 96
92 × 92
144 × 144
138 × 138
Additional Options Avaliable
Red Line
Nc
Phase Colour Bezel
Nc
Company Logo
Non standard Scaling
Red Adj Pointer
POA
POA
R27-00
Page 6
www.acorp.co.za
Electronic Kilowatt Hour Meters
General Specifications
Conform To
Accuracy
Operating Temp
AC Voltage withstand
Impulse Voltage withstand
Overcurrent withstand
Frequency Range
:National Standard GB / T 17215 - 2002
:IEC 61036 : IEC 521 : IEC 62053 - 21
:Class 1
: -15°C to +50°C
:2Kv for 1 min
:6Kv - 1.2/50us
:2400A / 0.5 Sec
:50 / 60Hz ±10%
LCD Direct Din Rail / Chassis Mount
617-00
Model DEM - 015SG 10 / 100A 35mm
Single Phase
Operational Green Indicator
: 5 / 100A Direct 8 Digit
: 230 VAC ± 20%
Pulse Rate Indicator Red
Terminal Shrouds supplied
LCD Backlit 9999999.1 KwH
Backup with maintenance free lithium battery
Dimensional Drawings & Wiring Diagrams for Kilowatt Hour Meters
LOAD
LCD 100A Direct Din Rail Chassis Mount
Model DEM - 024SJ
3 Phase 4 Wire Unbalanced Load
Power Consumption
1476-00
: 5 / 100A Direct
: 400 VAC ± 30%
: 2W and 10VA / Phase
L1 / L2 / L3 Light Indication
Phase Reversal Light Indicator
Impulse Output Light Display
Impulse Output Terminals
LCD Backlit 9999999.1Kwh
Backup with maintenance free lithium battery
Model DEM - 024SJ
H × W × D (mm)
140 × 70 × 68
Cut Out
45 × 70
Page 7
www.acorp.co.za
Electronic Kilowatt Hour Meters
General Specifications
Conform To
:National Standard GB / T 17215 - 2002
:IEC 61036 : IEC 521
:Class 1
: -15°C to +50°C
:2Kv for 1 min
:6Kv - 1.2/50us
:2400A / 0.5 Sec
:50 / 60Hz ±10%
Accuracy
Operating Temp
AC Voltage withstand
Impulse Voltage withstand
Overcurrent withstand
Frequency Range
LCD Direct Din Rail / Chassis Mount
Model DEM - 021LC
1476-00
5A CT Operated Only
3 Phase 4 Wire Unbalanced Load
Power Consumption
: 5A CT Connected
: 400 VAC ± 30%
: 2W and 10VA / Phase
LCD Backlit 9999999.1Kwh
Phase Failure Light Indication
Phase Reversal Light Indication
Impulse Output Light Display
Pulse Output Light Display
Impulse Output Terminals
Backup with maintenance free lithium battery
*Please Note: For CT connected meters calculate total reading as follows.
Eg. CT Ratio: 100/5 ÷ Factor 20 Take Actual Reading × 20
CT Ratio: 400/5 ÷ Factor 80 Take Actual Reading × 80
Wiring Diagram for 5A CT Connected
Supply
Mains Supply C/B
Red
Supply
White
Supply
Blue
P1
S2
S1
Model DEM - 021LC
H × W × D (mm)
88 × 125 × 68
Cut Out
45 × 125
P2
P1
S2
S1
P2
P1
S2
S1
P2
R W B 380V
NB
Connection Diagrams are for
illustration purposes only.
We suggest you protect 380V
supply to 9/11/13 Via a Fuse
or circuit breaker.
Page 8
www.acorp.co.za
AC Digital Panel Meter Series DG35B
General Specifications
Display
Accuracy
Operating Temperature
Insulating Resistance
Auxillary Supply
:12mm 3 digit LED Max. 999
: ±0.5%
:-10 to 50 Deg.
:2Kv / 1 min
:220VAC 50/60Hz
AC Meter Model DG 35BA
592-00
10 × Amp. Measuring Ranges Via Dip Switch Settings
15 / 25 / 40 / 60 / 99.9 / 150 / 250 / 400 / 600 / 999A
Input: 5A Ac from Current Transformers
AC Meter Model DG 35BV
592-00
Measuring Range: 40 to 99.9Hz
AC Meter Model DG 35BF
592-00
Measuring Range: 40 to 99.9Hz
Input Voltage: Between 40 & 600VAC
AC Digital Panel Meter Series DG 35B
Physical Size
Connection Diagram
H × W × D (mm)
85 × 52 × 75
Terminal 1 and 2
Aux 220V 50/60Hz
Panel Cut Out (mm)
Terminal 4 and 5
52 × 45
Amps / Volts / Frequency Input
Page 9
www.acorp.co.za
AC Digital Panel Meter Series DM 9648
General Specifications 96 × 48mm
Display
Accuracy
Operating Temperature
Insulating Resistance
Auxillary Supply
:12mm 3.5 Digit LED Max. 1999
: ±0.5%
:-10 to +50 Deg.
:2Kv / 1 min
:110 or 220VAC 50 / 60Hz Specify
Panel Cut Out
Terminal pretection cover on all meters
:93 × 45.5mm
ISO 9001 : 2000. CE
AC Ammeter Meter Model DM 9648-A
750-00
15 × Amp. Measuring Ranges Via Dip Switch Settings
60 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 /
750 / 800 / 1000 / 1200 / 1500 / 1999A
Input: 5A AC from Current Transformers
AC Voltmeter Meter Model DM 9648-V
750-00
AC Voltmeter Meter Model DM 9648-V PT Operated
810-00
Measuring Range: 0 to 600VAC
AC Frequency Meter Model DM 9648-F
Frequency Measuring Range
Input Voltage
750-00
: 40 to 99.9Hz
: Between 60 & 260VAC
2 in 1 Switchable AC Amp / Volt. Meter Model DM 9648-1
1231-00
15 × Amp. Measuring Ranges Via Dip Switch Settings
60 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 /
750 / 800 / 1000 / 1200 / 1500 / 1999A
Input
: 5A AC from Current Transformers
Voltage Measuring Range
: 0 to 600VAC
Page 10
www.acorp.co.za
AC Digital Panel Meter Series DPA 72 / 96
General Specifications 96 × 96mm
Display
Accuracy
Operating Temperature
Insulating Resistance
Auxillary Supply
:12mm 3.5 Digit LED Max. 1999
: ±0.5%
:-10 to +50 Deg. C
:2Kv / 1 min
220VAC 50Hz
Panel Cut Out
Terminal pretection cover on all meters
:92 × 92mm / 68 × 68mm
ISO 9001 : 2000. CE
AC Ammeter Model DPA-1 72 / 96
750-00
5A- 999A (In 5A Increments Electronically Set)
Input: 5A AC from Current Transformers
5A 1999A (In 5A Increments Electronically Set)
Input: 5A AC from Current Transformers
AC Voltmeter Model DPV-1 72 / 96
Measuring Range
: 0 to 600VAC
Size
: 72mm X 72mm
: 96mm X 96mm
Frequency Meter DPF-1 72 / 96
Measuring Range
: 40 to 99.9Hz
Input Voltage
: Between 40 & 600VAC
Outline Size (mm)
Panel Cut Out (mm)
72 × 72
68 × 68
96 × 96
92 × 92
750-00
750-00
Page 11
www.acorp.co.za
Multi-Display AC Digital Panel Meter Series DMCP-3
3× Individual / LED Displays / Meter
General Specifications 96 × 96mm
Display
Accuracy
Operating Temperature
Insulating Resistance
Auxiliary Supply
:12mm 3.5 Digit LED Max. 1999
: ±0.5%
:-10 to +50 Deg. C
:2Kv / 1 min
220VAC 50Hz
Panel Cut Out
Terminal pretection cover on all meters
:92 × 92mm
ISO 9001 : 2000. CE
AC Ammeter Model DMCP96 - 3A
1633-00
15 × Amp. Measuring Ranges Via Dip Switch Settings (×3)
60 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 1200 / 1500 / 1999A
Input: 5A AC from Current Transformers
3× Simultaneous Displays
AC Voltmeter Model DMCP96 - 3V
Measuring Range
3× Simultaneous Displays
1633-00
: 0 to 600VAC (×3)
Combination AC Amp / Volt / Frequency Meter
Model DMCP96 - 3M
1633-00
15 × Amp. Measuring Ranges Via Dip Switch Settings
60 / 100 / 150 / 200 / 250 / 300 / 500 / 600 / 750 /
800 / 1000 / 1200 / 1500 / 1999A
Input
: 5A AC from Current Transformers
Voltage Measuring Range
: 40 to 600VAC
Frequency Measuring Range
: 40 to 99.9Hz
Input Voltage
: Between 40 & 600VAC
3× Simultaneous Displays
Single Display Switchable AC Amp / Volt / Frequency Meter
Model DMCP96-1
1331-00
Specifications as per above DMCP963M
Also Avaliable Ex. Import
Multi Range Single & 3 Phase Power Factor (PF)
Page 12
www.acorp.co.za
Emfis Digital Multifunction Panel Mounted Meter
Cost effective solution to multifunction electrical parameter measurement.
Unique Features
Displays: Voltage Current Frequency,
Power* / Power Factor etc.
Large 3 Line Backlit LCD type Display
For 3 Phase 4 Wire Network
IP 54 Degree of Protection
Emfis VIF
1766-00
Measures & Displays 17 parameters including:
•
Phase to Phase Voltage
•
Phase to Neutral Voltage
•
Average Current
•
Total Current
•
Max Demand Current over 15 Min Time Adjustable
•
•
•
Instantaneous Current
Maximum Current
Frequency
Technical Specifications
Wiring Diagram
Enclosure:
Dimensions
Weight
: 96mm × 96mm × 86mm
: 300gms
Display
Digit Height
Protection Index
: 3 Line Backlit LCD Display
: 8mm × 4.8mm
Front Panel:
Inputs:
Current
Via Current Transformer
with Primary
Insulated Secondary
Current Circuit Burden
Overload
Voltage
Measurement Range
Voltage Circuit Burden
Auxiliary Supply:
: IP 54
: from 5A to 6000A configurable
in multiples of 5
: 5A / 1A
: <0.1VA
: 7A
: 60V AC to 600V AC
Phase Neutral
: <2VA
: 230 VAC ±30% 50Hz Burden <2.5VA
: 92 ×92mm
Cut Out
Sealing Facility Provided
City Power Approved
Page 13
www.acorp.co.za
Temperature Controllers
Application:
Widely used in all kinds of cold storage, low-temperature freezers and kitchen refrigerators.
Main Features:
User friendly operation mode, convenient for customers to use or replace.
With the function of copy card, users can set the parameters quickly
during batch production or after sale service, saves time and cost.
Flexible parameter setting: Sensor NTC/PTC optional, switch between
Celsius and Fahrenheit. Switch between refrigeration and heating mode.
Model: ETC-974
Type
Price
ETC-974
919.00
ETC-974
Technical Parameters:
Temperature measuring range: NTC: -50°C~110°C (-58°...230°F)
PTC: -55°C~140°C (-67°...284°F)
Temperature controlling range: -5°C~55°C
Relay contact output capacity: 10A / 250VAC
Working voltage: 230VAC± 10%, 50/60Hz
Resolution: 1 or 0.1°C
Sensor: NTC (10K / 25°C, B value 3435K) PTC (990 / 25°C)
Accessories:
2 probes, 1 operational instructions and 2 elastic tabs.
Wiring Diagram:
250V 250V
10A 10A
250V
10A
1
2
3
4
5
N.C.
Line
Def
Comp. Fan
6
7
Supply
220VAC
8
9
10
Pb2
Copy key
Pb1
Page 14
www.acorp.co.za
Temperature Controllers
Application:
Widely used in the beverage cabinets, display cases, kitchen cabinets, etc.
Main Features:
User friendly operation mode, convenient for customers to use or replace.
With the function of copy card, users can set the parameters quickly during
batch production or after sale service, high savings with time and cost.
Flexible parameter setting: Sensor NTC/PTC optional, switch between
Celsius and Fahrenheit. Switch between refrigeration and heating mode.
Model: ETC-902
Type
Price
ETC-902
889.00
ETC-902
Technical Parameters:
Working voltage: 230VAC± 10%,50/60Hz
Temperature controlling range: -50°C~99°C
Resolution: 1°C / 0.1°C (Switch between interger mode and decimal mode)
Accuracy: ±0.5°C (-15°C~30°C), others ± 1°C
Sensor type: NTC (-50°C~120°C); PTC (-50°C~150°C)
Accessories:
1 probe, 1 operational instructions and 2 elastic tabs.
Wiring Diagram:
1
2
3
4
6
5
7
Copy key
Line
Comp.
220VAC
Probe
Page 15
www.acorp.co.za
Temperature Controllers
Application:
Suitable for middle-low temperature cold storage, wind cooling cabinets,
kitchen cabinets, operating consoles and refrigerating display cabinets.
Main Features:
Refrigerating, timing defrost modes optional
Temperature exceeding alarm
Upper and lower temperature limit setting
Compressor delay protection time is fixed at 3 minutes
Sensor error occurs, compressor turns on/off with proportional time
Model: STC-8080A+
Type
Price
STC-8080A+
1113.00
STC-8080A+
Specifications:
Mounting size: 71 X 29 (mm)
Product size: 78.5 X 34.5 X 82 (mm)
Technical parameters:
Power supply: 220VAC + 10% / -15%, 50/60HZ
Supply: 220V
Tempreture measuring range: -50°C~+99°C
Tempreture controlling range: -40°C~+50°C
Resolution: 1°C
Accuracy: (-40°C~50°C, ±1°C); others ±2°C
Compressor output contact capacity: 7A/220VAC
Sensor type: NTC, 2M
Wiring Diagram:
Shell: Grey ABS flame retardant material
7A/220VAC
7A/220VAC
1
2
3
4
5
6
Compressor
Co-point
Closed point
Defrost
Co-point
Closed point
Accessories:
STC-8080A+
1 probe, 1 operational instructions and 2 elastic tabs.
7
8
9
10
11
Storage sensor
Power supply
220VAC
Page 16
www.acorp.co.za
Temperature Controllers
Application:
Widely used in middle and high-end air-cooled beverage cabinets,
display cases, kitchen cabinets, ect.
Main Features:
Innovative design and beautiful, display area increases 50%, the character indicates work status,
front panel waterproof level IP65. Easier installation: with the plug-in terminal, more reliable and
higher efficiency.
Adopt 30A big relay, could directly drive 1.5HP single phase compressor,
reducing the material cost for customers.
It abandons the screw slot design at the rear of the shell, avoiding the
loss caused by the condensing dripping on the circuit board.
ECS-100
Model: ECS-100
Type
Price
ECS-100
1113.00
Specifications:
Mounting size: 71 X 29 (mm)
Product size: 78.5 X 34.5 X 85 (D) (mm)
Technical parameters:
Measuring range: -50°C ~ +90°C (when the sensor calibration is at 0)
Accuracy: (-40°C~50°C, ±1°C); (50°C~70°C, ±2°C); others ±3°C
Supply: 220V
Resolution: 0.1C
Temperature control range: -50°C~50°C
Power Supply: (220±10%) VAC 50Hz
Power consumption: < 3W
Output capacity:
Wiring Diagram:
Refrgeration: 30A/240VAC, directly drive loading of 1.5HP (240VAC)
Defrost: 5A/250VAC
Fan: 5A/250VAC
Front panel protection level: IP65
5A
5A 1.5HP/240VAC
250VAC 250VAC
(MAX)
Working enviroment Temperature: 0°C~55°C
Storage Temperature: -25°C~75°C
1
2
5
3 probe, 1 operational instructions and 2 elastic tabs.
N
N
to
Cabinet Tempreture sensor
Accessories:
to
Evaporator sensor
N
L
N
220VAC
50/60Hz
Relative humidity: 20%~85% (on condensed)
Condenser sensor
4
Door switch
3
to
Page 17
www.acorp.co.za
Temperature Controllers
Functions:
220VAC power supply, sensor error indication, small size for easy installation.
Suitable for refrigerated cabinets and display cabinets ect.
Model: TPM-900+
Type
TPM-900+
TPM-900+
Price
418.00
Specifications:
Mounting size: 59 X 26 (mm)
Product size: 64 X 31 (mm)
Technical Parameters:
Power supply: 220VAC± 10%, 50/60Hz
Temperature measuring range: -30°C~110°C
Resolution: 0.1°C (<100°C), 1°C (≥100°C)
Accuracy: ±1°C
Page 18
www.acorp.co.za
Acorp CT’s
General Specifications
All CT’s According to IEC 44-1 Spec
DM20 Din Rail
Max System Voltage : 720V AC 50/60Hz
Compact Design
Secondary Terminal Protection Cover
CT 45/14 Chassis Mount
Ease of connection on secondary terminals.
CT’s are supplied with brackets for Din Rail & Chassis Mounting - Depending on model.
Model CT 45 / 14 14mm ID
30 to 100A
Type
Range
VA
Class
Price
CT14
30 / 5A
1
1.0
123.00
CT14
40 / 5A
1.5
1.0
123.00
CT14
50 / 5A
2.5
1.0
123.00
CT14
60 / 5A
1.5
1.0
123.00
CT14
75 / 5A
2.5
1.0
123.00
CT14
80 / 5A
2.5
1.0
123.00
CT14
100 / 5A
2.5
1.0
123.00
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Din Rail Mounting
Model DM 20 Mini Ring 20mm ID
Type
Range
VA
Class
Price
DM20
50 / 5A
1.0
1.0
123.00
DM20
60 / 5A
1.0
1.0
123.00
DM20
75 / 5A
1.5
1.0
123.00
DM20
80 / 5A
1.5
1.0
123.00
DM20
100 / 5A
2.5
1.0
123.00
DM20
125 / 5A
2.5
1.0
123.00
DM20
150 / 5A
2.5
1.0
123.00
DM20
200 / 5A
2.5
1.0
123.00
DM20
250 / 5A
2.5
1.0
123.00
DM20
300 / 5A
2.5
1.0
123.00
50 to 300A
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Page 19
www.acorp.co.za
Acorp CT’s
General Specifications
All CT’s According to IEC 44-1 Spec
Max System Voltage : 720V AC 50/60Hz
Secondary Terminal Protection Cover (can be sealed)
CT’s are supplied with brackets for Din Rail / Chassis and Busbar Mounting Kits.
Ease of connection on secondary terminals.
Model PWCT Wound Primary
1 to 50A
Type
Range
Range
VA
Class Price 1A Price 5A
PWCT
N/A
1 / 1A
0.6
1.0
175.00
PWCT
N/A
2 / 1A
0.6
1.0
175.00
PWCT
N/A
2.5 / 1A
0.6
1.0
175.00
PWCT
5 / 5A
5 / 1A
2.0
3.0
175.00
175.00
PWCT
10 / 5A
10 / 1A
2.5
1.0
175.00
175.00
PWCT
15 / 5A
15 / 1A
2.5
1.0
175.00
175.00
PWCT
20 / 5A
20 / 1A
2.5
1.0
175.00
175.00
PWCT
25 / 5A
25 / 1A
2.5
1.0
175.00
175.00
PWCT
30 / 5A
30 / 1A
2.5
1.0
175.00
175.00
PWCT
40 / 5A
40 / 1A
2.5
1.0
175.00
175.00
PWCT
50 / 5A
50 / 1A
2.5
1.0
175.00
175.00
Model CP62/30 Ring CT 30mm ID
50 to 150A
Type
Range
Range
VA
Class Price 1A Price 5A
CT30
50 / 5A
50 / 1A
2.5
1.0
123.00
123.00
CT30
60 / 5A
60 / 1A
2.5
1.0
123.00
123.00
CT30
75 / 5A
75 / 1A
2.5
1.0
123.00
123.00
CT30
80 / 5A
80 / 1A
2.5
1.0
123.00
123.00
CT30
100 / 5A
100 / 1A
5
1.0
123.00
123.00
CT30
125 / 5A
125 / 1A
5
1.0
123.00
123.00
CT30
150 / 5A
150 / 1A
5
1.0
123.00
123.00
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Page 20
www.acorp.co.za
Acorp CT’s
General Specifications
All CT’s According to IEC 44-1 Spec
Ease of connection on secondary terminals.
Max System Voltage : 720V AC 50/60Hz Secondary Terminal Protection Cover (can be sealed)
CT’s are supplied with brackets for Din Rail / Chassis and Busbar Mounting Kits.
200 to 800A
Model CP40 Ring CT 40mm ID
Type
Range
Range
VA
Class
CT40
200 / 5A
200 / 1A
5
1.0
133.00
133.00
CT40
250 / 5A
250 / 1A
5
1.0
133.00
133.00
CT40
300 / 5A
300 / 1A
5
1.0
133.00
133.00
CT40
400 / 5A
400 / 1A
5
1.0
145.00
145.00
CT40
500 / 5A
500 / 1A
10
1.0
145.00
145.00
CT40
600 / 5A
600 / 1A
10
1.0
145.00
145.00
CT40
800 / 5A
10
1.0
145.00
145.00
Price 1A Price 5A
Model CP50 Ring CT 50mm ID
Type
Range
Range
VA
Class Price 1A Price 5A
CT50
250 / 5A
5
1.0
175.00
CT50
300 / 5A
5
1.0
175.00
CT50
400 / 5A
5
1.0
175.00
CT50
500 / 5A
10
1.0
175.00
CT50
600 / 5A
10
1.0
175.00
CT50
800 / 5A
10
1.0
175.00
CT50
1000 / 5A
10
1.0
175.00
Model CP60 Ring CT 60mm ID
Range
Range
VA
CT60
200 / 5A
200 / 1A
5
1
242.00
242.00
CT60
250 / 5A
250 / 1A
5
1
242.00
242.00
CT60
300 / 5A
300 / 1A
5
1
242.00
242.00
CT60
400 / 5A
400 / 1A
5
1
242.00
242.00
CT60
500 / 5A
500 / 1A
10
1
242.00
242.00
CT60
600 / 5A
600 / 1A
10
1
242.00
242.00
700 / 1A
10
1
242.00
242.00
CT60
Class
Price 1A Price 5A
Type
CT60
800 / 5A
800 / 1A
10
1
242.00
242.00
CT60
1000 / 5A
1000 / 1A
15
1
242.00
242.00
CT60
1200 / 5A
15
1
242.00
CT60
1250 / 5A
15
1
242.00
CT60
1500 / 5A
15
1
242.00
CT60
1600 / 5A
15
1
242.00
CT60
2000 / 5A
15
1
242.00
: P1 - P2
Primary Current
Secondary Current : S1 - S2
250 to 1000A
: P1 - P2
Primary Current
Secondary Current : S1 - S2
200 to 2000A
: P1 - P2
Primary Current
Secondary Current : S1 - S2
Page 21
www.acorp.co.za
Acorp CT’s
General Specifications
All CT’s According to IEC 44-1 Spec
Max System Voltage : 720V AC 50/60Hz
Secondary Terminal Protection Cover (can be sealed)
CT’s are supplied with brackets for Din Rail / Chassis and Busbar Mounting Kits.
Ease of connection on secondary terminals.
500 to 2500A
Model CP80 Ring CT 80mm ID
Type
Range
VA
Class
Price 1A Price 5A
CT80
500 / 5A
15
1.0
CT80
600 / 5A
15
1.0
272.00
CT80
800 / 5A
15
1.0
272.00
CT80
1000 / 5A
20
1.0
272.00
CT80
1200 / 5A
20
1.0
272.00
CT80
1250 / 5A
20
1.0
272.00
CT80
1500 / 5A
20
1.0
272.00
CT80
1600 / 5A
20
1.0
272.00
CT80
2000 / 5A
20
1.0
272.00
CT80
2500 / 5A
20
1.0
272.00
272.00
272.00
Model CP100 Ring CT 100mm ID
Primary Current
: P1 - P2
Secondary Current : S1 - S2
800 to 3200A
Note: For Chassis and Busbar mount only
Type
Range
VA
Class
Price 5A
CT100
800 / 5A
10
1.0
308.00
CT100
1000 / 5A
20
1.0
308.00
CT100
1200 / 5A
20
1.0
308.00
CT100
1250 / 5A
20
1.0
308.00
CT100
1500 / 5A
20
1.0
308.00
CT100
1600 / 5A
20
1.0
308.00
CT100
2000 / 5A
25
1.0
405.00
CT100
2500 / 5A
25
1.0
405.00
CT100
3000 / 5A
25
1.0
405.00
CT100
3200 / 5A
25
1.0
405.00
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Page 22
www.acorp.co.za
Acorp CT’s
General Specifications
All CT’s According to IEC 44-1 Spec
Max System Voltage : 720V AC 50/60Hz
Secondary Terminal Protection Cover (can be sealed)
CT’s are supplied with brackets for Din Rail / Chassis and Busbar Mounting Kits.
Ease of connection on secondary terminals.
Model ABO / 125 Ring CT 125mm ID
2000 to 5000A
Type
Range
VA
Class
Price 5A
CT125
2000 / 5A
10
1.0
502.00
CT125
2500 / 5A
10
1.0
502.00
CT125
3000 / 5A
10
1.0
550.00
CT125
3200 / 5A
15
1.0
550.00
CT125
4000 / 5A
15
1.0
550.00
CT125
5000 / 5A
15
1.0
550.00
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Clamp On Mini Split Core Current Transformers
100 to 800A
Model Uk40 / 40 Ring CT 40mm ID
Type
Range
VA
Class
Price 5A
UK40
100 / 5A
1.5
1.0
726.00
UK40
150 / 5A
1.5
1.0
726.00
UK40
200 / 5A
2.5
1.0
726.00
UK40
250 / 5A
2.5
1.0
726.00
UK40
300 / 5A
2.5
1.0
726.00
UK40
400 / 5A
5
1.0
726.00
UK40
500 / 5A
5
1.0
726.00
UK40
600 / 5A
5
1.0
726.00
UK40
800 / 5A
5
1.0
726.00
Primary Current
: P1 - P2
Secondary Current : S1 - S2
Page 23
www.acorp.co.za
Acorp CT’s
Acorp Mini Split Core Transformers
The connection of conventional CT’s usually require interruption on the primary
side of the circuit to pass cables or Busbars through the transformer or to connect
such cables to the primary terminals. The MSCT series transformers can be easily
opened, installed and connected without any supply interruption, thus saving time
and the installation costs.
Specifications:
Features:
•
•
•
•
•
Rated Frequency
Rated test voltage
Operating temperature
Secondary Current
Max System Voltage
Accuracy
Light weight, compact dimensions.
Simple installation / Hinged Opening
Built in over voltage protection.
Complete with Meter Cables for
Secondary Connections.
Therefore no possibility of loose connections.
Model M24SCT Ring CT 24mm ID
: 50/60Hz
: 3kV AC / 1 MIN
: -15°C - 55°C
: 5A
: 720V AC 50/60Hz
: Class 1.0 / 3.0
50A to 300A
Type
Range
VA
Class
Price 5A
M24SCT
50 / 5A
1.5
3.0
677.00
M24SCT
100 / 5A
1.5
3.0
677.00
M24SCT
150 / 5A
1.5
3.0
677.00
M24SCT
200 / 5A
0.5
1.0
677.00
M24SCT
250 / 5A
0.5
1.0
677.00
M24SCT
300 / 5A
0.5
1.0
677.00
Primary Current
Primary Current
Secondary Current
Secondary Current
S1 RED
Model M36SCT Ring CT 36mm ID
Line
Load
Red
Black
S2 Black
400A to 600A
Type
Range
VA
Class
Price 5A
M36SCT
400 / 5A
2.5
1.0
713.00
M36SCT
500 / 5A
2.5
1.0
713.00
M36SCT
600 / 5A
5
1.0
713.00
Model M24SCT
: P1
: P2
: S1
: S2
Primary Current
Primary Current
Secondary Current
Secondary Current
: P1
: P2
: S1
: S2
Line
Load
Red
Black
Model M36SCT
W × H × D (mm)
45 × 65 × 34
W × H × D (mm)
67 × 85 × 40
DIA
24
DIA
36
S2 Black
S1 RED
Page 24
www.acorp.co.za
DBP Series Split Core Current Transformers
The connection of conventional CT’s usually require interruption on the primary
side of the circuit to pass cables or Busbars through the transformer or to connect
such cables to the primary terminals. The DBP series transformers can be easily
opened, installed and connected without any supply interruption, thus saving time
and the installation costs.
Features:
•
•
•
Two built in fixing methods: Base and
Busbar mounting.
Wide inner window, allowing clamping
of big existing installations.
Primary Current from 100 - 5000A
Type
Ratio
(A)
Burden (VA)
Class:0.5
Specifications:
Rated Frequency
Rated test voltage
Operating temperature
Secondary Current
: 50/60Hz
: 3kV AC
: -10°C - 50°C
: 5A
*other technical specifications, on request.
D
C
ID
Price
AXB
Class:1
DBP-23
100/5
2.5
110
89
20×30
798.00
DBP-23
150/5
2.5
110
89
20×30
798.00
DBP-23
200/5
2.5
110
89
20×30
798.00
DBP-58
150/5
1.5
145
114
50×80
907.00
DBP-58
200/5
2.5
145
114
50×80
907.00
DBP-58
250/5
2.5
145
114
50×80
907.00
DBP-58
300/5
2.5
145
114
50×80
907.00
DBP-58
400/5
1.5
2.5
145
114
50×80
907.00
DBP-58
500/5
2.5
5
145
114
50×80
907.00
DBP-58
600/5
2.5
5
145
114
50×80
907.00
DBP-58
800/5
3.75
5
145
114
50×80
907.00
DBP-58
1000/5
5
10
145
114
50×80
907.00
DBP-812
800/5
2.5
5
200
144
80×120
1331.00
DBP-812
1000/5
3.75
7.5
200
144
80×120
1331.00
DBP-812
1250/5
5
10
200
144
80×120
1331.00
DBP-812
1500/5
7.5
10
200
144
80×120
1331.00
DBP-812
2000/5
7.5
10
200
144
80×120
1331.00
DBP-812
2500/5
7.5
10
200
144
80×120
1331.00
DBP-812
3000/5
7.5
10
200
144
80×120
1331.00
DBP-812
4000/5
7.5
10
200
144
80×120
1331.00
DBP-816
1000/5
10
15
245
184
80×160
2117.00
DBP-816
2000/5
10
15
245
184
80×160
2117.00
DBP-816
2500/5
15
20
245
184
80×160
2359.00
DBP-816
3000/5
20
25
245
184
80×160
2359.00
DBP-816
4000/5
20
25
245
184
80×160
2359.00
DBP-816
5000/5
20
25
245
184
80×160
2359.00
Standards:
IEC60044-1, EN60044-1
VDE0414-44-1, GB1208-2006
Page 25
www.acorp.co.za
Acorp CT’s
Acorp MSCT’s / Mini Sub CT
General Specifications
All CT’s According to IEC 44-1 Spec
Max System Voltage : 720V AC 50/60Hz
Secondary Terminal Protection Cover.
CT’s are supplied with Screws for Busbar Mounting.
Model MSCT / Mini Sub CT
500 to 800A
Type
Range
VA
Class
Price 5A
MSCT
500 / 5A
7.5 / 15
0.5 / 1.0
157.00
MSCT
600 / 5A
7.5 / 15
0.5 / 1.0
157.00
MSCT
800 / 5A
7.5 / 15
0.5 / 1.0
157.00
Coloured Caps for Phase Indication
Red
White
Blue
Suitable for Busbars 40 X 10 and 50 X 10.
42mm
Primary Current
: P1 - P2
Secondary Current : S1 - S2
P1
45˚
43mm
100mm
12mm
12mm
53mm
M6
S2
23mm
S1
Bracket Side View
Page 26
www.acorp.co.za
Acorp CT’s / Shunts
Maximum System Voltage: 660V AC
Chassis Mounting Summation CT’s
In Addition to our standard range of CT’s, we are able to supply the following:
•
Non Standard CT’s manufactured to client’s specifications
•
5P10 and 5P20 / 10P10 & 10P20 range of CT’s
•
Resin Cast CT’s for Protection and metering
•
Spilt core and Clamp-on CT’s
•
Interposing CT’s
Please contact us for pricing and delivery with regards
to your specific requirments.
Class 1 10VA
Summation CT
1 + 1 / 1A and 5 + 5 / 5A
646-00
Class 1 10VA
Summation CT
1 + 1 + 1 / 1A and 5 + 5 + 5 / 5A
974-00
Class 1 10VA
Summation CT
1 + 1 + 1 + 1 / 1A and 5 + 5 + 5 + 5 / 5A
1197-00
DC Shunts
Class 1%
Range
50 & 60mV
10 - 40A
335-00
50 - 100A
375-00
150A
430-00
200A
470-00
250 - 300A
765-00
350 - 450A
1060-00
500 - 600A
1450-00
650 - 800A
1910-00
800 - 1000A
2340-00
1200A
3360-00
1500A
4350-00
1800A
5640-00
2000A
6250-00
2500A
6740-00
3000A
7440-00
4000A
9560-00
4000A+
POA
For 75/100mV Add 20%
For 150/200mV Add 50%
Page 27
www.acorp.co.za
CT Dimension Page (mm)
Model
IDMM
A
B
G
PWCT
85
40
CT14
65
42
14
H
I
J
L
M
O
P
53
DM20
20
65
35
20
43
CT20
20
88
57
20
62
CT30
30
88
57
30
11
11
21
31
62
21
26
CT40
40
88
57
31
11
16
31
41
62
21
26
CT50
50
98
57
41
12
31
41
51
80
21
31
CT60
60
120
57
51
12
21
51
61
101
31
44
CT80
80
126
57
65
12
31
51
81
105
31
56
CT100
100
155
52
88
31
51
61
101
145
31
81
CT125
125
233
58
125
125
192
65
126
M24SC
24
65
34
24
45
M36SC
36
85
40
36
67
UK40
40
120
35
40
115
DBP23
110
40
20
90
30
DBP58
145
45
50
115
80
DBP812
200
45
80
145
120
DBP816
245
65
80
185
160
65
Page 28
www.acorp.co.za
Acorp Current Transducers
Introduction
The CE-T Series Providing Analogue Output Signal 4-20mA
Series
Operating
Principal
Isolation
Voltage
Mounting
CE-IJ03A
Electro
Magnetic
2500VDC
Din Rail
& Screw
1 Element AC Current Transducer
Type
Aux
Input
Output
Price
TCESA-220
220 VAC
5A
4-20mA
1143.00
TCESA-110
110 VAC
5A
4-20mA
1143.00
TCESA-24
24 VAC
5A
4-20mA
1143.00
S1
S1
S2
S2
Page 29
www.acorp.co.za
Moulded Terminal Blocks for Chassis Mounting
Rated Current Carrying Capacity : 600VAC
All With Plexiglass Terminal Protection Cover
Cadmium Plated Terminal Screws / Bolts
IN12BK
20A - 2 Pole
20-00
IN13SBK
20A - 3 Pole
30-00
IN20BK
30A - 3 Pole
42-00
IN30BK
50A - 3 Pole
65-00
IN411S
60A - 1 Pole
45-00
TB - 153
15A - 3 Pole
14-00
TB - 154
15A - 4 Pole
15-00
TB - 156
15A - 6 Pole
23-00
TB - 1512
15A - 12 Pole
46-00
TB - 253
25A - 3 Pole
33-00
TB - 254
25A - 4 Pole
41-00
TB - 256
25A - 6 Pole
52-00
TB - 2512
25A - 12 Pole
60-00
TB - 603
60A - 3 Pole
71-00
TB - 604
60A - 4 Pole
96-00
TB - 1003
100A - 3 Pole
121-00
TB - 1004
100A - 4 Pole
133-00
TB - 1503
150A - 3 Pole
154-00
TB - 1504
150A - 4 Pole
175-00
TB - 2003
200A - 3 Pole
205-00
TB - 2004
200A - 4 Pole
248-00
TB - 3003
300A - 3 Pole
399-00
TB - 3004
300A - 4 Pole
465-00
TB - 4003
400A - 3 Pole
598-00
TB - 4004
400A - 4 Pole
671-00
Page 30
www.acorp.co.za
Acorp Battery Charger
General Specifications
Power Input Display
Voltage Power
Efficiency
:100 / 220 V AC 50/60Hz
: 80” - Full Load
DC Output
Bat12 Voltage 13.8 VDC Current 5A
Bat24 Voltage 27.6 VDC Current 3A
Charge Mode
Float
Contact Capacity
Weight
DC Voltage Regulator
Dimensions
120V AC 0.5A
<1”
± 0.800 Grams
112.5mm - L 130mm - W 73mm - H
Model Battery Charger
1270-00
Mode of Operation
1. When Power is ON, check charge current LED bat. The
current will decrease as the battery charges.
2. When Battery voltage is less than 10V DC the Bat < 10”
LED will illuminate and the low voltage charge fail alarm
relay will energize.
3. The voltage sensing circuit automatically shuts off the
power when the battery is fully charged.
Installation
1. Make sure you are using the correct battery
charger 12 or 24 V DC.
2. Connect Input Voltage to L1 & L2.
3. The LED marked “P1” on the panel should be
illuminated when the power is on. The DC output
voltage should be as follows:
Model BAT12 : 13.8 + / - 0.2V DC
Model BAT24 : 27.6 + / - 0.2V DC
4. With power off connect output terminals “±” to
the battery lead “±”
5. Use terminal lugs on connection to prevent wires
from shorting.
Protection
Current limiting protection
Short circuit protection
Reverse polarity protection
Dimensional Drawing (mm)
Important
1. Disconnect the power supply before any connection or
disconnection is done.
2. Potentially lethal voltages are present inside.
Do not open case and attemp any adjustments or repair on
this unit with the power on.
3. Minimum voltage on the battery must be higher than 5V DC
or the battery charger will automatically switch off.
4. This is not a power supply, use only for battery charging.
5. For use in protected environment only.
Page 31
www.acorp.co.za
cc Credit Application
6 Arnheim Circle - Lonehill - 2062 - PO Box 76
Tel: 011 467-3788/1695
E-mail: info@acorp.co.za
Fax: 011 705-1842
Trading Information
Company Name
Trading Name
Street Address
Postal Address
Telephone Number & Area Code
Fax Number & Area Code
Cellular Number
E-mail Address
Date Company Established
Type of Business
Company Registration Number
Vat Registration Number
Partnership
Public
Private
Close Corporation
Sole Proprietor
Company Information
Telephone Number
Name
Financial Director
Accounts
Buyer
Banking Details
Banking Group
Branch Name
Branch Name
Account Number
Account Number
Preferred Meathod
of Payment
Cash
Bank Guaranteed
Cheque
Company
Cheque
Electronic
Bank Transfer
References
Company Name
Contact Person
Telephone
Credit Limit
Account Number
Credit Limit Required R
Signed By:
Date:
Signature:
Page 32
www.acorp.co.za
Acorp Standard Terms & Conditions Of Trading
Prices as quoted :In SA Rand / each
:VAT not Included
:Subject to discount as indicated on data sheet
Validity :Until Further Notice
Delivery :Ex Stock Subject to prior sale
:F.O.B. Johannesburg
:Allow Approx. 2/7 days for non standard items
All goods remain the sole property of Acorp until fully paid for.
Factory & Warehouse
Postal
No. 6 Arnheim Circle
Lonehill
2062
Gauteng
Po Box 76
Lonehill
2062
Contact Details
Contact Details
TEL : +27 11 467 3788
Charles Friedrichs
(Marketing)
076 141 7936
TEL : +27 11 467 1695
FAX : +27 11 705 1842
James Daly
(Accounts)
082 540 2851
086 575 0058
E-mail : info@acorp.co.za
Website : www.acorp.co.za
Banking Details
Nedbank
Current Account : 1224092031
Branch Code : 122-405
VAT : 4480255415
Page 33