Recessed LED

advertisement
Recessed LED
ArcForm (36), Pique (91), PureFX (94), Vectra (97) and Voice (98)
1
Power
Feed
Driver
Standalone
Installation Instructions
Bend mounting tab
2
Adjust height of tab
3
Lay fixture into T-grid
Driver
Driver
Clip for 1-11/16"
T-bar height
Every fixture contains its own driver and receives a direct power feed.
!
Clip for 1-1/2" or
1-3/4" bolt-slot grid
T-bar height
DRYWALL & AIR RETURN
If installing in DRYWALL or if fixture includes AIR RETURN, some steps on this
instruction sheet may not be applicable. Refer to separate drywall and air return
instruction sheets.
4
Bend tabs flush
5
Bend tabs flush against T-grid in order to
clear corner for ceiling tile.
!
Fasten fixture to T-grid
Use a #8x1/4" sheet metal screw
to fasten fixture to T-grid and
use a hanger wire to tie off
appropriately in accordance with
local building codes (screws and
hanger wires supplied by others).
Bend out mounting tab 90 degrees on
each corner.
6
Electrical connections
Make all electrical connections to
the fixture.
Note: For flex whip option, see
Step 6a.
Use side cutters to adjust each tab to
height of T-grid.
6a
Flex whip (optional)
Optional Flex whip is prewired
inside fixture. Remove packaging and
insert snap-in fitting into wiring cover.
Complete electrical connections at
other end of whip in accordance with
local building codes.
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2012 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
Lay fixture into T-grid.
ID-Recessed_LED_ST.pdf
Page 1
02-12
Recessed LED
ArcForm (36), Pique (91), PureFX (94), Vectra (97) and Voice (98)
Power
Feed
1
Driver
Driver
Driver
Driver
Continuous Row
Installation Instructions
Bend mounting tab
2
Adjust height of tab
3
Lay fixture into T-grid
Driver
Clip for 1-11/16"
T-bar height
Fixtures are joined together in a continuous row and serviced by one power feed.
Thru-wiring is provided, with quick-wire connectors and knock-outs at fixture ends.
Every fixture contains its own driver.
!
Clip for 1-1/2" or
1-3/4" bolt-slot grid
T-bar height
DRYWALL
If installing in DRYWALL, some steps on this instruction sheet may not be
applicable. Refer to seperate drywall instruction sheet.
4
Bend tabs flush
5
Bend tabs flush against T-grid in order
to clear corner for ceiling tile.
!
Fasten fixture to T-grid
Use a #8x1/4" sheet metal screw
to fasten fixture to T-grid and
use a hanger wire to tie off appropriately
in accordance with local building
codes (screws and hanger wires
supplied by others).
Bend out mounting tab 90 degrees on
each corner.
6
Attach adjacent fixtures
Remove connecting knock-outs and
attach adjacent fixtures to the T-grid
following steps 1-5. Place a 1/2" nipple
through the knock-out hole between
the fixtures. Fasten with a 1/2" NPT
lock nut (nipple and lock nut supplied
by others).
Use side cutters to adjust each tab
to height of T-grid.
7
Electrical connections
between fixtures
Feed the wires through the nipple and
make all the electrical connections
between the fixtures following the
correct wiring color code. Attach the
wiring access cover plates.
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2012 Philips Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
Lay fixture into T-grid grid.
8
Electrical connection to
the first fixture
Ensure that the wiring of the last fixture
in the row is properly terminated. Then
make all electrical connections to the
first fixture in the row. Attach the wiring
access cover plate.
ID-Recessed_LED_CR.pdf
Page 1
02-12
Recessed LED
ArcForm (36), Pique (91), PureFX (94), Vectra (97) and Voice (98)
Power
Feed
1
Driver
Driver
1
Driver
1 2
1
Bend out mounting tab 180 degrees on each
corner.
2x2 Air Return Version
Installation Instructions
Bend out mounting tab 180 degrees on each
Bend out mounting tab 180 degrees on each
corner.
Bend mounting tabcorner.
4
2
4
2
4
Adjust height of tab
2
3
Use side cutters to adjust each tab to the
height of the T-bar. Use side cutters to adjust each tab to th
3
Layheight
fixture
into T-grid
of the T-bar.
3
Every fixture contains its own driver and receives a direct power feed.
The air return version features slotted
vents along the sides of the fixture. As
Use side cutters to adjust eachLay
tabfixture
to into T-bar
Bend out mounting tab 180 degrees on
Lay fixture
into T-grid.
a result, the installation method of the
grid
the
height
of
the
T-bar.
each
corner.
Bend
out
mounting
tab
180
degrees
on
each
Use
side
cutters
to
adjust
each
tab
to
the
Bend out mounting
180version
degreesison
each to the Bend out mounting
Usetab
side
cutters
to adjust
each tab to the
180
degrees
on each
Use side cutters to adjust each tab to the
air tab
return
different
corner.
height of the T-bar.
corner.
height of the T-bar.
corner.
height of the T-bar.
standard version, and the fixture cannot
Air return
be installed in continuous rows.
vents
Bend tabs flush against the T-bar in order
Lay fixture into T-bar grid
4
4
Lay fixture into T-bar grid
!
4
Bend tabs flush
5
3
5
35
5 6
6
Phone: 604.888.6811
Bend tabs flush against the T-bar in order
6
to clear the ceiling tile.
6
6
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2012 Philips Ledalite
5
6
to clear the ceiling tile.
Electrical connections
Fasten fixture to T-grid
Use a #8x1/4” sheet metal screw to fasten
fixture to the T-bar grid and use a hanger wire
to tieMake
off appropriately
in accordance
Bend tabs flush against the T-bar in
all electrical connections
towith
the
Use
aflush
#8x1/4”
sheet
metal
screw
Bend
tabs
against
the
T-bar
in
order
Lay fixture intoLay
T-bar
grid
Bend metal
tabs flush
against
the T-bar local
in order
fixture into T-bar grid
building codes (screws
hanger wires
Useclear
a #8x1/4”
sheet
screw
to fasten
Makeand
all electrical
connections
Bend to
tabs
flush
to
the
ceiling
tile.
order
clear
theagainst
ceilingthe
tile.T-bar in order
fixture.
to fasten to
fixture
to the
T-bartile.
grid
clear
the
ceiling
totothe
T-bar grid and use a hanger wire supplied
byelectrical
others). connections to the fixture.
to clear the ceiling
Use atile.
#8x1/4” sheet metalfixture
screw
fasten
Make all
and
use
a
hanger
wire
to
tie
off
to tie
offaappropriately
fixture to the T-bar grid and
use
hanger wire in accordance with
appropriately
accordance
with local
buildingwith
codesin(screws
and hanger
wires
to tie off appropriately inlocal
accordance
supplied
by others).
building
codes
(screws
and
hanger
local building codes (screws and hanger wires
wires supplied by others).
supplied by others).
5
5
43
Lay fixture into T-bar grid
Fax: 800.665.5332
Web: ledalite.com
ID-Recessed_LED_Air.pdf
Page 1
02-12
Recessed LED
ArcForm (36), Pique (91), PureFX (94), Vectra (97) and Voice (98)
!
IMPORTANT
If you are installing any configuration type other than
standalone, additional steps are required for wiring.
Please refer to the installation instructions for that
configuration type to determine wiring requirements.
1
Install drywall kit
Install drywall kit frame in ceiling. Refer to
Drywall Kit specification sheet for mounting
options and ceiling opening sizes.
4
Open lens frame
Push up on center channel of lens frame and shift
in direction of hinges. Lens frame will then swing
open in a downward direction. If fixture has lens
frame restraint, release by pressing inwards.
!
Installation in Drywall or Ceilings
Requiring Flanges
2
Make all electrical
connections
Make all electrical connections to the
fixture. Attach wire access cover plate.
5
Phone: 604.888.6811
Fax: 800.665.5332
Web: ledalite.com
Lay fixture into drywall
kit frame
Lay fixture into drywall kit frame.
Fasten fixture
Use a #8x1/4" sheet metal screw (supplied by
others) to fasten fixture to drywall kit frame from
inside of housing. Repeat on each corner.
ATTENTION: Install in accordance with national and local building and electrical codes.
© 2012 Philips Ledalite
3
ID-Recessed_LED_Drywall.pdf
Page 1
02-12
Download