June 6, 2003 Dowser Control Notes Using Console Dimmer Curve Profiles to obtain smoothest fade performance. A “square” dimmer profile as found on the ETC Express and Expression series, and Strand 500 series* can be used to enhance the smoothness of the dowser fade in the 1-4 second range. Console Tested ETC Express250 Strand 520 Dimmer Curve IES Square Law Square Curve # on Console 1 99 When using a mix of tungsten and MSR sources using split fade times for cues will best manage the different response times of these light sources (as per moving light practice). Programme the fade to start the tungsten sources first and then add the MSRs. For example for a 5 second fade: Cue 1 Part 1 2 Action Tungsten Dowser Time infade 5 sec infade 3 sec Wait 0 sec 2 sec Longer fades (over 10 seconds) with a final lower output level (up to approx. 25%) may operate best with the standard dimmer profile. Experiment with different curves and fade times to produce the best result for your show. * Results with other consoles may vary. www.seleconlight.com Page 1 of 1