Maximum HP Ratings
Maximum HP Ratings
Poles
115-230
Volts AC
1
2
1 hp
1 hp
115-230
Volts DC
Cat. #
Poles
115-230
Volts AC
115
Volts DC
3⁄4
A-B BUL 600 TOX4
A-B BUL 600 TOX5
1
2
1 hp
1 hp
1 hp
1 hp
hp
Single Gang
Hub
Poles Size
3⁄4
1
1
3⁄4
2
1
1
2
1
3⁄4
1
Typedriver Name: TS name csm no.: 100
230
Volts DC
1⁄4 hp
1 hp
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Cat. #
GE-CR101-Y
GE-CR101-H
Single Gang
Dead
end
Cat. #
EDS2199†
EDS3199†
EDS21100†
EDS31100†
Through
feed
Cat. #
EDSC2199†
EDSC3199†
EDSC21100†
EDSC31100†
EDS2299†
EDS3299†
EDS22100†
EDS32100†
EDSC2299†
EDSC3299†
EDSC22100†
EDSC32100†
Hub
Poles Size
3⁄4
1
1
3⁄4
2
1
Two Gang
3⁄4
TCP: 15001
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7B*CD,9EFG,12
EDS Factory Sealed Manual
Motor Starting Switches and
Enclosures
2C
COLOR: CMYK
Dead
end
Cat. #
EDS21093†
EDS31093†
EDS21094†
EDS31094†
Through
feed
Cat. #
EDSC21093†
EDSC31093†
EDSC21094†
EDSC31094†
EDS22093†
EDS32093†
EDS22094†
EDS32094†
EDSC22093†
EDSC32093†
EDSC22094†
EDSC32094†
Two Gang
1
2
3⁄4
1
3⁄4
1
These heaters are for motors rated 40°C continuously. For motors rated 50°C or 55°C, multiply full load motor current by 0.9 and use this value to
select heaters. Symbol 0 (zero) must be used to indicate heater omitted.
Heater Table (Allen-Bradley)
Max. Motor
Full-Load
Amps
0.17
0.21
0.25
0.32
0.39
0.46
0.57
0.71
0.79
0.87
0.98
1.08
1.19
1.30
1.43
1.58
1.75
1.88
2.13
2.40
2.58
CrouseHinds Symbol
Number
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P21
Max. Motor
Full-Load
Amps
2.92
3.09
3.32
3.77
4.16
4.51
4.93
5.43
6.03
6.83
7.72
8.24
8.9
9.6
10.8
12.0
13.5
15.2
Heater Table (General Electric)
CrouseHinds Symbol
Number
P22
P23
P24
P25
P26
P27
P28
P29
P30
P31
P32
P33
P34
P35
P36
P37
P38
P39
Max. Motor
Full-Load
Amps
.48
.53
.58
.65
.71
.78
.86
.95
1.04
1.14
1.25
1.37
1.49
1.63
1.78
1.95
2.13
2.32
2.53
2.76
CrouseHinds Symbol
Number
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
G17
G18
G19
G20
G21
Max. Motor
Full-Load
Amps
3.01
3.27
3.56
3.88
4.22
4.60
5.00
5.43
5.90
6.41
6.98
7.60
8.25
8.95
9.75
10.6
11.4
12.5
13.6
14.8
16.0
CrouseHinds Symbol
Number
G22
G23
G24
G25
G26
G27
G28
G29
G30
G31
G32
G33
G34
G35
G36
G37
G38
G39
G40
G41
G42
† Includes one interchangeable heater. Select heater from the table below individual listings and use symbol number as second section of the Cat. No. Example: EDS2199-P5. Insert symbol 0
(zero) to omit heater.
* Add GB suffix. Seals must be installed within 11⁄2⍯ of each conduit opening for Group B usage.
356
STIBOINFO((CRH:66008com:2C:356))
CH0 2 C- 1 3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
Zoom: 100
2:
5:
SYS19: BASE2
PDFINFO
50:
95:
98:
JOB: CRMAIN06-0355-5 Name: 2C-355
100:
DATE: JAN 19 2006
Time: 5:19:31 PM Operator: JB
EDS Factory Sealed Manual
Motor Starting Switches and
Enclosures
COLOR: CMYK
TCP: 15001
Cl. I, Div. 1 & 2, Groups B*,C,D
Cl. II, Div. 1, Groups E,F,G
Cl. II, Div. 2, Groups F,G
Cl. III
NEMA 3,7B*CD,9EFG
Typedriver Name: TS name csm no.: 100
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
2C
Standard Finishes:
Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural
ɀ Type 6/6 nylon – black
ɀ Stainless steel – natural
Certifications and
Compliances:
EDSC2199
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups B*,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
ɀ NEMA/EEMAC: 3,7B*CD,9EFG
ɀ UL Standard: 894, 698
ɀ CSA Standard: C22.2 No. 30
EDS2299
Application:
Factory sealed enclosures are installed in a
rigid metallic conduit system for surface
mounting adjacent to or remote from
equipment being controlled and are used:
ɀ to prevent arcing of enclosed device from
causing ignition of a specific hazardous
atmosphere or atmospheres external to the
enclosure
ɀ in industrial areas such as chemical plants,
oil and gas refineries, paint and varnish
manufacturing plants, gasoline bulk loading
terminals, grain elevators, grain processing
industries, coal processing or handling areas,
or metal handling or finishing areas where
atmosphere may contain hazardous gases
and/or dust
ɀ in non-hazardous areas where sturdy,
durable enclosures are required
ɀ in conjunction with magnetic starters or
contactors for remote control of motors
Manual motor starting switch enclosures are
used:
ɀ for manual starting of small ac or dc motors
ɀ to provide manual starting and stopping
and, in the case of units with heaters, motor
running protection
Options:
Suffix to be
Added to
Cat. #
Description
For use in Group B hazardous areas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GB*
Bodies and covers (single and two gang units) – copper-free aluminum. . . . . . . . . . . . . . . . . . . SA
Standard Materials:
ɀ Bodies – Feraloy® iron alloy (U.S.); copper-free aluminum (Canada).
ɀ Shafts & bushings – stainless steel
ɀ Sealing enclosures – copper-free aluminum
Dimensions (inches)
Features:
Dimensions are approximate, not for construction purposes.
Side Hub Dim. Dim.
View Size ‘‘h’’ ‘‘i’’
7⁄8
13⁄16
3⁄4
15⁄16
1
1
Front View
Factory sealed devices have many distinct
advantages:
ɀ reduce installation problems
ɀ eliminate external seals
ɀ lower installation costs
ɀ improve safety
ɀ mounting lugs and taper tapped hubs with
integral bushings
ɀ large machine screws for fastening covers
to bodies
ɀ lockout hole for padlock having 1⁄4⍯ hasp is
provided
ɀ close tolerances in machining of wide,
mating flanges and journalled shafts and
bearings produce flametightness of
enclosure joints
ɀ dead end (EDS) or through feed (EDSC)
hubs – 3⁄4⍯ or 1⍯ sizes
Single gang
Two gang
Surface covers have
same length and
width as single & 2
gang bodies.
* Seals must be installed within 11⁄2⍯ of each conduit opening in Division 1
US: 1-866-764-5454
STIBOINFO((CRH:66008com:2C:355))
CH0 2 C- 1 7
CAN: 1-800-265-0502
Copyright© 2006 Cooper Crouse-Hinds
355
Zoom: 100
Download