3.5 kW - 5 kW - 230 VAC/50 Hz

advertisement
WP-AC Belt Power - Belt Driven 230V Generator
marine • mobile
3.5 kW - 5 kW - 230 VAC/50 Hz
- Heavy-duty system to generate 230 VAC/50 Hz
- Stable, sine wave power at variable speed
- Compact & easy to install
- High efficient & compact generator solution
- Suitable to operate with Combi’s
s m art e n e rg y so lu tio n s
Datasheet
s m a rt e n e rg y s o lu t io n s
Beltpower
Art. Nr.
4130100041302000
Specifications W-BD 3.5 W-BD 5
Power (continuous) 3500 W 5000 W
Max current (continuously) 16 A 27 A
Max. inrush current (320 ms) 32 A 40 A
Voltage 230 VAC 230 VAC
Frequency 50 Hz 50 Hz
How it works
The WhisperPower W-BD alternator is designed for installation in the
vehicle’s or boat’s engine compartment and has to be driven by a belt
of one of the engine’s pulley. In most cases an additional pulley has to
be installed. The alternator’s output is connected to an inverter/power
supply, which converts the variable incoming current into a stable sine
wave 230 VAC 50 Hz.
Standard Pulleys and Pulleys
to client specification
Inverter box
Dimensions (h*w*d) 376*323*127 mm (app.)
Net weight 9.6 Kg
9.6 Kg
Efficiency 95%
95%
Depending on the vehicle model, mounting
brackets to mount the generator on the engine
could be available or can be specially designed
Generator
Pulley
Safety alarms
Net weight 6.9 Kg
Dimensions (h*w*d) 159*178*190 mm
Short circuit, overload, over temperature, low/
high rpm, low/high voltage
Voltage 200-340 VAC 3 phase
Determine the pulley diameter design
Field voltage 14.4 VDC
6.9 Kg
The graphs show the available AC power corresponding to the generator
speed. The speed of 2 pulleys relate to each other proportional to the
diameter of the pulleys. First one need to know the engine speed =
116*79*19 mmcrankshaft speed when idling and at full speed. When the drive pulley
is not on the crankshaft the rpm of the pulley drive shaft must be
determined. The pulleys should be selected in such a way that at low
speed the generator can bring the power required. However the max.
speed must not exceed 15000 RPM.
3600
14.4 VDC
3400
3200
3000
2800
2600
Remote Control Panel
2400
WATT
2200
Dimensions (h*w*d) 2000
1800
1600
1400
1200
1000
800
600
400
200
0
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
RPM
3400
4800
3200
3000
4400
2800
4000
2600
3600
2200
3200
2000
2800
WATT
WATT
2400
1800
1600
1400
2400
2000
1200
1600
1000
1200
800
600
800
400
400
200
0
2000
Attention!
5200
3600
2500
3000
3500
4000
4500
5000
5500
6000
6500
RPM
Speed/power diagram W-BD 3.5 (3.5 kW)
7000
0
2000
2500
3000
3500
4000
4500
5000 5500 6000
RPM
6500
Speed/power diagram W-BD 5 (5 kW)
5200
7000
7500
8000
8500 9000
T he W-BD5 model needs 6500 RPM to
generate 5 kW. Compared with
the W-BD 3.5 the 5 kW
model will also need more
RPM (3200) to generate
1 kW. Refer to the graph.
Remote panel for Belt Power,
with various settings
4800
4400
4000
3600
WATT
3200
2800
2400
2000
1600
1200
800
400
2500
3000
3500
4000
4500
5000 5500 6000
RPM
6500
7000
7500
8000
8500 9000
WhisperPower BV Kelvinlaan 82, 9207 JB Drachten, The Netherlands, Tel: +31 (0) 512 571 550, Fax: +31 (0) 512 571 599, info@whisperpower.com, www.whisperpower.com
28092012datasheetBELTp
0
2000
Installation drawing w-bd generator
Download