Informatica® Corporation Data Integration Hub Version 9.6.2 Release Notes June 2015 Copyright (c) 1993-2015 Informatica Corporation. All rights reserved. Contents New Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Upgrade Changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation and Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Fixed Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Known Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Informatica Global Customer Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 This document contains important information about main features, installation, and known limitations for Data Integration Hub. New Features For a list of new features and enhancements in Data Integration Hub, see the Data Integration Hub Release Guide. Upgrade Changes For a list of behavior and functionality changes after you upgrade Data Integration Hub, see the Data Integration Hub Release Guide. Installation and Upgrade Before you install or upgrade Data Integration Hub, verify that your system meets the minimum requirements and follow the pre-installation steps. For information about installing or upgrading Data Integration Hub, see the Data Integration Hub Installation and Configuration Guide. DIH-RLN-96000-0001 1 Installation and Upgrade Limitations Issue Description XE-10798 When you install Data Integration Hub in a Windows operating system, if you clear all the options in the Installation Components page and then navigate to the previous page, Installation Directory, you cannot navigate from the Installation Directory page back to the Installation Components page. Workaround: Verify that at least one component is selected on the Installation Components page before you leave the page. XE-10575 When you upgrade to version 9.6.2 and your publication repository runs on a Microsoft SQL Server, if partitioning was previously enabled on the repository but is disabled at the time of the upgrade, if you re-enable partitioning after the upgrade, the partitioning function contains a datetime data type and you cannot create topics in Data Integration Hub. Workaround: Before you re-enable partitioning on the repository, delete all Data Integration Hub partition functions. For example: DIH__DATE_PARTITION_FUNCTION. XE-9809 When you install Data Integration Hub on a Windows Operating system, if you install the Data Integration Hub client plugin for PowerCenter component and define a custom ODBC connection string, the string, user name, and password that you define during the installation are not saved to the plugin. When you create custom workflows, event status names are not loaded into PowerCenter Designer. Workaround: Take one of the following steps: - Enter the string, user name, and password in the following file: <DIHInstallationDir>/powercenter/pluginVERSION/dxplugin.xml - Manually enter event status names in PowerCenter Designer. 2 XE-8373 On an existing Data Integration Hub installation where you changed your configuration files since the installation, when you add components to Data Integration Hub using the Data Integration Hub installer, the Data Integration Hub installer does not present the configuration data that you modified after the original installation during the component installation. Workaround: Verify that the data that the installer presents during component installation is correct, and correct it if required. XE-6870 When you install or uninstall Data Integration Hub on IBM AIX operating systems in console mode, an error message might appear with the following text: Hostname and service name not provided or found. Workaround: Ignore the error message. XE-6569 When you install Data Integration Hub on IBM AIX 6.1 operating systems, an error message might appear with the following text: Unzip: not found. Workaround: Ignore the error message. DIH-RLN-96000-0001 Fixed Limitations Review the Release Notes of previous releases for information about previous fixed limitations. Issue Description XE-10071 The Dashboard is not supported on IBM AIX operating systems. XE-9911 When the following settings are enabled in the dx-configuration.properties file, the pmrep process does not end if Data Integration Hub crashes: - pwc.pmrep.use.process.pool - pwc.pmrep.process.pool.max Note: To end the pmrep process, enable the system property dih.onstartup.clean.stale.pmrepinstances. XE-8527 The first time that you test connections in Data Integration Hub, the test might fail with an error. Workaround: Wait one minute and then test the connection. If the test fails after you wait a few seconds, delete the folder DIH__SYSTEM_WORKFLOWS in PowerCenter, and then test the connection. XE-7482 You can only use the default Data Integration Hub schema to connect to data sources and data targets. Workaround for Oracle databases only: If you don't want to use the default schema to which Data Integration Hub connects, in the connection properties, append the following string to the connection string: ALTER SESSION SET CURRENT_SCHEMA=<schema name> You must define an identical schema in the following fields: - In the Metadata Access section, in the Connection String field. - In the Data Access section, in the Environment SQL field. Known Limitations CR Description XE-10849 For topics where the structure of a topic contains columns with a DOUBLE data type, if you open the topic for editing in the Operation Console, when you save the topic, Data Integration Hub regards the action as a topic structure change, regardless of whether you edit the topic or not. Data Integration Hub deletes the data of all columns with a DOUBLE data type, and the publications and subscriptions that are associated with the topic become not valid. To re-validate the publications and subscriptions that are associated with the topic, after you save the topic, run the publication or the subscription wizard for each associated publication or subscriptions. XE-10841 When an aggregated subscription consumes more than a thousand publications in an aggregated mode, there might be cases where data is consumed twice. XE-10623 The option to kill stale pmrep processes does not work on IBM AIX operating systems. Workaround: Do not enable the system property dih.onstartup.clean.stale.pmrepinstances on IBM AIX operating systems. XE-10324 When you use the Run Publication Subscription web service API to run publications and subscriptions, Data Integration Hub does not enforce data access when connecting to the source application or to the target application. DIH-RLN-96000-0001 3 CR Description XE-10292 Users that do not have view privileges for workflows cannot edit publications and subscriptions. XE-9806 When you publish a flat file source, the name of the topic table can contain up to 77 characters. XE-9754 Subscription runs fail when the subscription contains a filter for a column with a TEXT data type with a Does Not Equal operator and the option Use pushdown optimization is enabled for the subscription. XE-9749 Data Integration Hub publication repository on a Microsoft SQL Server: If a string is longer than the field precision of the topic table in the staging database, the string is truncated without notification. XE-9725 When you use Microsoft Windows authentication for a system connection, DIH__REPO or DIH__STAGING, the wrapper.log file contains an incorrect error. XE-9341 Failure to create an index for a topic column might require a manual intervention to fix the topic. XE-9194 Custom delimiters that are used in flat files must be expressible as a 7-bits ASCII character. For example, you cannot use Japanese characters as delimiters. XE-9193 When you define the structure of the topic by extracting the table structure from a file, and when you create a publication with a flat file source, the Data Integration Hub Operation Console shows a preview of the file only if the file is an ASCII code page. XE-9114 For aggregated subscriptions and for compound subscriptions, the Event Average Processing Time report includes multiple delayed events in the calculation, and not only the aggregated event or the compound event. XE-9089 When you change the default data storage location on the publication repository, a warning message appears, stating that the storage location has changed and that the topic tables will be recreated. The topic metadata is changed and holds the new default storage location. Topic tables are not recreated on the new storage location, and remain on the old storage location. Workaround: Edit the topic and change the Data Storage Location to the new default data storage location on the publication repository. XE-9028 For publications with a publication pre-process, the Event Average Processing Time report does not calculate the pre-processing time. XE-8782 The Data Integration Hub command-line utilities do not work in Windows PowerShell on Windows Server 2012. Workaround: Use the Windows command shell to run command-line utility commands. Windows command shell is available in the following location: C:\Windows\System32\cmd.exe 4 XE-8752 Microsoft SQL database where partitioning is enabled: If the retention period of a topic is set to one day Data Integration Hub cannot delete the topic data from the publication repository. Only data that is older than one day is moved onto the partition. Workaround: Set topic retention period for two or more days. XE-8744 After you change the default file group on the Data Integration Hub staging repository, when you edit a topic that was created before the change, a message informs you that unconsumed data that was published from the topic will be discarded. Topics that existed before you changed the default file group continue to publish to the file group that was the default group when the topic was created. Changing the default file group does not discard unconsumed data that was published before the change. DIH-RLN-96000-0001 CR Description XE-8625 When you delete from the PowerCenter repository a connection that Data Integration Hub created in the PowerCenter repository, Data Integration Hub does not re-create the PowerCenter connection when you test or save the connection in Data Integration Hub. Workaround: In the Data Integration Hub Connections page change an option in the connection, save the connection, change the option to the original value, and save the connection. For example: Change the value of the Connection Retry Period, save the connection, change the value of the Connection Retry Period to the original value, and save the connection. XE-8524 When you export a publication from a Data Integration Hub machine and then import the publication to a Data Integration Hub machine with a different source structure, or when you export a subscription from a Data Integration Hub machine and then import the subscription to a Data Integration Hub machine with a different target structure, Data Integration Hub retains the structure of the exported source or target during import. When you run a publication or a subscription with an incompatible structure, the publication or the subscription either fails or writes data that is not be valid. For example: On a Microsoft SQL Server, if you export a publication from a machine where the source structure is a table with the columns A and B, and import the publication into a machine where the source structure is a table with the columns B and A. Workaround: Edit the data structure of the imported publication or subscription and then run it. XE-8374 Data Integration Hub does not support the dxProhibitReprocess event attribute. Data Integration Hub reprocesses subscriptions when the attribute is set. XE-8333 When you use a database password that ends with the # character, Data Integration Hub enters the password into the PowerCenter connection without the # character. XE-8182 The publication fails when all the following conditions exist: - The data source is DB2. - The publication contains BLOB or 'VARCHAR FOR BIT DATA data types. - There is a NULL value in the binary column of the source table. XE-8068 Data Integration Hub does not support versioned PowerCenter repositories. XE-8058 When you install Data Integration Hub with Informatica domain authentication and the PowerCenter Web Services Hub, you must specify the same machine for both components. XE-7923 When you delete an event attribute with dependent objects, unsupported B2B Data Exchange objects might appear in the confirmation message. XE-7907 When you install Data Integration Hub in console mode, you cannot type Back in the PowerCenter Location section. Workaround: Exit and restart the installation. XE-7900 On Data Integration Hub repositories that run on a Microsoft SQL Server, when a user deletes a publication, other users cannot complete the creation of new publications. When a user deletes a subscription, other users cannot complete the creation of new subscriptions. XE-7877 When you add a topic table from a Microsoft SQL Server database connection, the topic table names cannot contain square brackets. XE-7765 If you do not use a precision license, and you publish from a Microsoft SQL Server database source, MAX values of MONEY and SMALLMONEY data types might be converted to a value that is higher or lower than the values that the Microsoft SQL Server database target supports. This results in a publication error. XE-7656 The Data Integration Hub Operation Console lists event-types that are relevant for B2B Data Exchange. DIH-RLN-96000-0001 5 CR Description XE-7442 Publications and subscriptions might fail with the following error after you edit them: "Error: Folder [ID=xx] not found". Perform one of the following workarounds: - After the publication or subscription fails, you must restart the PowerCenter Repository Service. - To avoid the failure, disable Repository Agent Caching in the PowerCenter Repository Service properties before you edit the publication or the subscription. XE-7305 When all the child events of a publication are a Discarded status, the Consumption Status of the parent event is empty and not Discarded. XE-7247 When you use Data Integration Hub with Informatica platform authentication, user synchronization fails if you change the case of a user name in the Informatica domain. For example, if you changed the user name from JohnSmith to johnsmith, the Informatica domain handles the updated user name as a new user account. However, Data Integration Hub handles the updated user name as a duplicate user account. Workaround: 1. 2. 3. 4. XE-7190 Remove the user from the Informatica domain security group. Synchronize users with Data Integration Hub. The synchronization deletes the user account from Data Integration Hub. Add the user account to the Informatica domain security group. Synchronize users with Data Integration Hub. The synchronization adds the updated user account to Data Integration Hub. To change the Data Integration Hub server RMI port number on a Windows operating system, you must change the port number in both copies of the dx-configuration.properties file and in the wrapper.conf file. For more information about changing default port numbers, see the Data Integration Hub Installation and Configuration Guide. Informatica Global Customer Support You can contact a Customer Support Center by telephone or through the Online Support. Online Support requires a user name and password. You can request a user name and password at http://mysupport.informatica.com. The telephone numbers for Informatica Global Customer Support are available from the Informatica web site at http://www.informatica.com/us/services-and-training/support-services/global-support-centers/. 6 DIH-RLN-96000-0001