Surge Protection for Railway Applications Electric trains Medium-voltage networks Level crossings Railway stations and their signalling BE ON THE SAFE SIDE Surge Protection for railway stations and signalling/security systems Surge protection for power supply networks EMI and overvoltage protection for electronic devices As every important structure, the railway stations need to be adequately protected. The most important equipment to protect are security systems and computer networks. Overvoltage protection for data lines Surge protection for level crossing and railway electrification systems Surge protection for traction vehicles Surge protection for medium-voltage networks and electric trains Railway applications use AC or DC power supply networks for electric trains and other railway vehicles. The surge protection has to be installed on the railway network power supply line and every railway vehicle. Lightning overvoltage: direct strike to mast, wires & track, induced voltages due to indirect strikes. Switching & other surges: pantograph arcing, breaker operations, feeder cable arcing fault, induced switching surges, short circuit, insulation flashovers, TOV. Surge protection for power supply networks in traction systems Overvoltage protection for data lines Surge protection for power supply networks Overvoltage protection for telecommunication lines Level crossings Equipotential bonding protection At level crossings, the surge protection is obligatory. Unless the power supply, signal and telecommunication parts are protected, the overvoltages can destroy the equipment. Overvoltage protection has to be installed on every incoming line. Surge protection for railway stations and signalling/security systems SAFEBLOC BR 100/275 (3+1) Category IEC / EN / VDE: Location of use: Protection modes : Safety: Iimp ( 10/350) per pole: Complies with: Class I, Type 1 / B Main distribution board L - N, N - PE Immunity against TOV 25kA IEC-61643-1, EN-61643-11, PrEN 50539-11, UTE C 61-740-51 PROFILT D 8A Category IEC / EN / VDE: Location of use: Protection modes : Uoc/Isc (1,5/50 , 8/20): IL: LZ-NET 6 LAN protector IEC category / EN type: Location of use : Protection: Frequency: Uc: IL: In (8/20): Class III, Type 3 / D As close as possible to devices L - N, N - PE 6kV/3kA 8A C1 / C2 / C3 (IEC 60643-21) As close as possible to a protected devices All 4 pairs protected < 100MHz, Cat 6 Capable 48VDC 1A 10kA (lines- PG) Surge protection for level crossings and railway electrification systems SAFETEC CR 160/275 (3+1) Category IEC / EN / VDE: Class II, Type 2 / C Location of use: Sub-distribution board Protection modes: L - N, N - PE Safety: Immunity against TOV Imax (8/20) per pole: 40kA Complies with: IEC-61643-1, EN-61643-11, PrEN 50539-11, UTE C 61-740-51, UL 1449 Third Edition SMH-RC 24V Single-pair Data SPD for shielded cables IEC category / EN type: C1 / C2 / C3 (IEC 60643-21) Location of use: As close as possible to devices Protection: Longitudinal, transverse Uc: 28VDC IL: 1A In (8/20): 10kA LPA 02 K1 + LSA strip Location of use : Protection: Uc: IL: In (8/20): As close as possible to devices Longitudinal, transverse 180VDC 300mA 5kA MSAIZ-RT 3DC Location of use: Protection: Protective elements: Nominal voltage Un: Traction vehicles Railroad installation MOV 3kVDC MSAIZ-RN 3DC Location of use: Protection: Protective elements: Nominal voltage Un: Power supply networks in traction systems Railroad installation MOV 3kVDC EPZ 100/350 Location of use: Exposed environments or direct burial Protective elements: GDT Imax (8/20): 100kA DC sparkover voltage (100V/s): 350V Published by: ISKRA ZAŠČITE, d.o.o. / March 2012 / Design: Dacar / ISKRA ZAŠČITE d.o.o., Surge Voltage Protection Systems, Engineering and Cooperation Stegne 35, 1521 Ljubljana, Slovenia, EU P: 00386(1)5003 100; F: 00386(1)5003 236 E: sales@iskrazascite.si; www. iskrazascite.si We reserve the right to introduce changes in performance, dimensions and materials in the course of technical progress. Copyright All rights reserved No part of this work, nor of the information laid down herein and/or derivable herefrom and/or developed in connection herewith, may be reproduced or used in any form or by any means. Legal action will be taken against infringements. This publication replaces the previous edition