GFCI Personnel Safety Devices
Smartlock® GFCI Device
Smartlock® GFCI devices comply with 2003 UL requirements.
HOSPITAL GRADE
8598-HGR
● Power/Diagnostic
Indicator
● 15 & 20Amp
Configurations
● Back and Side Wired
● Color Match Test/Reset
Buttons (Monochromatic)
● Green LED Indicates
Power and Confirms
Proper Wiring Status
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
Smartlock® GFCI Device Types
COMMERCIAL C-PACK
● 15 Amp Single GFCI
Receptacle with
Single-Pole Switch
● Switch Rated 8.3
Amps at 120V AC
● Back and Side Wired
● Color Match
Test/Reset
Buttons (Monochromatic)
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
● 20 Amp with Switch
Rated Test/Reset
Buttons
● Back and Side Wired
● Color Match
Test/Reset Buttons
(Monochromatic)
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
8299-G
PAGE F3
PAGE F3
● Blank Face
● Contact Rating:
20A 125V
● Control Relay:
80 Amps 240VACMax.
● Side Wired
● Color Match Test/Reset
Buttons (Monochromatic)
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
●
Recognized
Component
8895-80E
ANGLE PLUG
Right Angle GFCI Plugs
● 15A 125V; 20A 125V
● Automatic and Manual
Reset Types
● Power Staus Indicator
● Available in Gray and
Yellow
●
Recognized
Component
6593
PAGE F4
8599-I
COMBO
PAGE F3
HIGH CURRENT
●15 & 20 Amp
Configurations
● Back and Side Wired
● Color Match Test/Reset
Buttons (Monochromatic)
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
● Available with 41/2”
pigtail leads
BLANK FACE
8590-W
8599-CPI
COMMERCIAL GRADE
PAGE F3
● 15 Amp
Configurations
● Back and Side Wired
● Black Reset & Red
Test Buttons
● Contractor Pack
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
PAGE F4
1
8598-E
● Power/Diagnostic
Indicator
● 15 & 20Amp
Configurations
● Back and Side Wired
● Color Match
Test/Reset
Buttons (Monochromatic)
● Green LED Indicates
Power and Confirms
Proper Wiring Status
● Resistant to Surge,
Noise, and Corrosion
Per 2003 UL
Requirements
PAGE F3
PAGE F3
F
COMMERCIAL GRADE PLUS
PANEL MOUNT
WORK LIGHT
Recognized
Component
66591-WL
36596
Panel Mount GFCI with16” Leads
● 20A 125V
● Orange LED Indicator Light
● Weather-Resistant Hosing & Test/Reset
Buttons
● Resistant to Surge, Noise, and Corrosion
Per 2003 UL Requirements
PAGE F4
CORD SETS
66591-25C
GFCI Cord Sets
● 15A & 20A 125V; 15A & 20A 240V
● Automatic and Manual Reset Types
● Orange Power Staus Indicator
● Yellow Cord 14/3 SJT
● Resistant to Surge, Noise, & Corrosion
Per 2003 UL Requirements
PAGES F5 & F6
To learn more about Leviton devices or for answers to technical questions call our Techline at
Fluorescent Work Light with GFCI Protected
Receptacle
● 13 Watt Lamp and Receptacle
● Black Body with 20’ Yellow Cord 16/3 SJTW
● NEMA 5-15R Receptacle; NEMA 5-15P Plug
● Automatic Reset In-Line GFCI with Power
Status Indicator
PAGE F4
POWER CENTER
PB101-SGF
“THE BOX”™
● 6 GFCI Protected 20A 125V Straight
Blade or Locking Receptacles
● GFCI Protected 30A 250V Locking Receptacle
● 50A 125/250V Non-NEMA Power Connections
● Meets OSHA Regulation 20, Subpart K
Strandards
● UL Listed for Outdoor Use
PAGE F7
1-800-824-3005 or visit us at:
www.leviton.com
SmartLock® GFCI Features
2 YEAR LIMITED
UL Standard 943 Class A (GFCI) & 498 (Receptacles)
CSA Certified (File #057)
Meets 2003 UL Requirements
Thick-walled, impact-resistant
thermoplastic nylon cover and
body withstands abuse
Heavy duty double wipe for
15 Amp contacts and triple
wipe for 20 Amp contacts
Silver alloy contacts for reliable
make/break switching.
Triple combination
terminal screws.
“Surge hardened” electronics
offer superior resistance to
surges and overvoltages.
LED power indicator light helps
diagnose improper wiring and,
when illuminated, offers visual
confirmation that power is
available.
Eight back-wired
holes (Four on
each side) provide
maximum wiring
capability.
Provisions for backor side-wiring.
Leviton® SmartLock® icon ensures
improved GFCI product design.
Lockout action blocks the
“RESET” button if GFCI protection
has been compromised.
COMPONENT
DESCRIPTION
Face
Nylon
Back
Nylon
Line Contacts
Brass
Terminal Screws
Brass #10-32
Grounding Screw
Brass #8-32
Yoke
Zinc Steel
Clamp Nuts
Internal Contacts
Steel
Silver Alloy
NEMA
ANSI
WD1&WD6
C-73
Advanced electronics design
provides superior resistance to
electrical surges and
over-voltages.
Leviton SmartLock® Meets or Exceeds These
Tougher Requirements Effective January 2003
• Diagnostic Indication for Miswiring
• Surge Immunity
• Corrosion Resistance
• False Tripping
STANDARDS & CERTIFICATIONS
UL
UL 943
CSA
Listed
Class A & 498
NOM
#E48380
#057
LED indicator offers visual
confirmation of power availability.
SmartLock® GFCI Features
Patented lockout feature prevents
“RESET” if GFCI is not functioning
properly or miswired due to reversal of
line and load leads.
#LR-57811
For additional details on these new requirements,
see page F9.
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
F
2
15A 125V & 20A 125V
Hospital & Commercial Grade, GFCI's
ELECTRICAL
DIELECTRIC
VOLTAGE
CURRENT
INTERR.
Withstands
1500V
per
UL 498
10kA
5±1 mA
STANDARDS & CERTIFICATIONS
MECHANICAL
TEMP.
RISE
TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot
TRIP LEVEL
2 YEAR LIMITED
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC appl.
per UL 498
#14 - #12 AWG
solid or stranded
copper wire
Grounding
Silver, neutral
NEMA ANSI
WD-6 C-73
PRODUCT
I.D.
Ratings
permanently
marked
on device
UL
UL
943 Fed Spec
Class A
Listed
& 498
WC-596
ENVIRONMENTAL
–
CSA
NOM
C22.2
#LR-57811 #057
AC HORSEPOWER RATINGS
FLAMMABILITY
OPERATING TEMP.
Rated V-2 per UL 94
-35C to 65C
1.5
Hospital & Commercial Grade GFCI Devices
Back & Side Wired
FACE
COLOR
GFCI
HOSPITALGRADE
SMARTLOCK®
DUPLEX w/ LED
Meets 2003
UL Requirements
GFCI
GFCI
GFCI
GFCI
GFCI
COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE
SMARTLOCK®
SMARTLOCK®
SMARTLOCK®
DUPLEX w/ RED &
BLANK FACE
BLACK BUTTONS
S-P SWITCH
DUPLEX w/ LED
DUPLEX
w/ 41/2” LEADS
Contractor Pack
1.5HP@120V AC
Meets 2003
UL Requirements
Meets 2003
UL Requirements
Meets 2003
UL Requirements
Meets 2003
UL Requirements
Meets 2003
UL Requirements
8598-HG
8598-HGI
8598-HGW
8598-HGG
8598-HGR
8598-HGE
8598-HGA
8598
8598-I
8598-W
8598-G
8598-R
8598-E
8598-A
8599
8599-I
8599-W
8599-G
8599-R
8599-E
8599-A
–
8599-LI
8599-LW
–
–
–
–
–
8599-CPI
8599-CPW
–
–
–
8599-CPA
–
8590-I
8590-W
–
–
8590-E
–
20A 125V, NEMA 5-20R at Receptacle & Feed-Through
Brown
Ivory
White
Gray
Red
Black
Almond
8898-HG
8898-HGI
8898-HGW
8898-HGG
8898-HGR
–
8898-HGA
FACE
COLOR
8898
8898-I
8898-W
8898-G
8898-R
–
8898-A
8899
8899-I
8899-W
8899-G
–
8899-E
8899-A
–
–
–
–
–
–
–
–
–
–
–
–
–
–
GFCI COMBO DEVICE RECEPTACLE
& SINGLE-POLE SWITCH
–
–
–
–
–
–
–
COLOR
SHALLOW WALLBOX
EXTENDER
FOR GFCI's
Meets 2003 UL Ruquirements
15A 125V, NEMA 5-15R;
20A 125V Feed-Through
1.53 (38.9 mm)
8598-HG & 8898-HG SERIES
Brown
Ivory
White
1.53 (38.9 mm)
8598,8898, 8599-L & 8599-CP SERIES
To learn more about Leviton devices or for answers to technical questions call our Techline at
6197
6197-I
6179-W
)
4.21 (106.93 mm)
)
)
4.21 (106.93 mm)
8299-I
8299-W
8299-G
8299-A
4.21 (106.93 mm)
Ivory
White
Gray
Almond
)
4.21 (106.93 mm)
3
8590-W
8599-CPI
15A 125V, NEMA 5-15R; 20A 125V Feed-Through
Brown
Ivory
White
Gray
Red
Black
Almond
8299-G
F
8599-LW
8599-I
8598-E
8598-HGR
1.53 (38.9 mm)
8590 SERIES
1-800-824-3005 or visit us at:
1.53 (38.9 mm)
8299 SERIES
www.leviton.com
15A 125V & 20A 125V
Commercial Grade, GFCI's
2 YEAR LIMITED
ELECTRICAL
DIELECTRIC
VOLTAGE
CURRENT
INTERR.
Withstands
1500V
per
UL 498
10kA
STANDARDS & CERTIFICATIONS
MECHANICAL
TEMP.
RISE
TERMINAL
I.D.
TERMINAL
ACCOMMODATION
Brass, hot
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
TRIP LEVEL
5±1 mA
#18- #12 AWG
Grounding
Silver, neutral
OPERATING TEMP.
Rated V-2 per UL 94
-35C to 66C
Gray
Yellow
86593
Right Angle Plugs Accessory
ANGLE PLUG
ANGLE PLUG
AUTOMATIC
RESET
COLOR
WATERPROOF COVER
WITH GROUND PIN UP
ORIENTATION
MANUAL
RESET
15A 125V, NEMA 5-15P
20A 125V, NEMA 5-20P
6593
–
6893
–
–
6594
#LR-57811 #057
1.5
6894
MANUAL
RESET
NOM
C22.2
AC HORSEPOWER RATINGS
FLAMMABILITY
Recognized Component
AUTOMATIC
RESET
–
CSA
Clear
–
6894
86593
High Current GFCI
Contact Rating: 20A 125V AC
Load Capability with 125V Control Relay
80@240V AC Max.
20A 125V
PANEL MOUNT GFCI w/ 16" LEADS &
LED LIGHT YELLOW LEXAN
TOGGLE
COLOR
36596
Ivory
PANEL MOUNT FOR TEMPORARY
POWER DISTRIBUTION BOXES
Front View
36597
Recognized Component
BLANK FACE
RESET BUTTONS
Side View
8895-80I
White
8895-80W
Black
8895-80E
Recognized Component
Commercial Grade GFCI’s
PLUG
COLOR
UL
UL
943 Fed Spec
Class A
Listed
& 498
WC-596
ENVIRONMENTAL
6593
Right Angle GFCI Plugs
NEMA ANSI
WD-6 C-73
PRODUCT
I.D.
Ratings
permanently
marked
on device
GFCI-Protected Fluorescent Work Light w/Receptacle
13A 125V, 2-P 3-W Grounding
GFCI CORD SET, YELLOW CORD, 16/3 SJTW
BLACK BODY, ON/OFF POWER SWITCH,
13 WATT LAMP & RECEPTACLE
W
5-15R
)
2.40 (64 mm)
.023 REF.
5.12 (130 mm)
4.75 (121 mm)
G
5-15P
2.58 (65.5 mm)
1.83 DIA.
(49 mm)
1.60 DIA.
(41 mm)
2.7 (68.6 mm)
W
NEMA
CONNECTOR
CLASS
3.8 (96.5 mm)
G
66591-WL
1.74 (44.2 mm)
~~~~~~~
~~~~~~
~~~~~~~
NEMA
PLUG
.810
(20.6 mm)
20’
4.21 (106.93 mm)
LENGTH
1.29 DIA.
(33 mm)
1.26 (32 mm)
36596
RIGHT ANGLE GFCI PLUGS
To learn more about Leviton devices or for answers to technical questions call our Techline at
8895
1-800-824-3005 or visit us at:
www.leviton.com
F
4
15A 125V&250V;20A125V&250V
Automatic Reset GFCI Cord Sets & Power Supply Cords
ELECTRICAL
DIELECTRIC
VOLTAGE
CURRENT
INTERR.
Withstands
1500V
per
UL 498
10kA
TERMINAL
I.D.
TERMINAL
ACCOMMODATION
Brass, hot
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
Automatic Reset GFCI Cord Sets & Power Supply Cords
TRIP LEVEL
5±1 mA
STANDARDS & CERTIFICATIONS
MECHANICAL
TEMP.
RISE
Not Applicable
Grounding
Silver, neutral
1 YEAR LIMITED
PRODUCT
I.D.
Ratings
permanently
marked
on device
ENVIRONMENTAL
NEMA ANSI
WD-6 C-73
UL
UL
943 Fed Spec
Class A
Listed
& 498
WC-596
–
CSA
#LR-57811 #057
AC HORSEPOWER RATINGS
FLAMMABILITY
OPERATING TEMP.
Rated V-2 per UL 94
-35C to 66C
1.5
Automatic reset GFCI cord sets (black body) automatically reset ON when power is restored.
66891-3
66591-25C
66593
FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations.
LENGTH
GFCI CORD SET AUTOMATIC RESET
(15 AMP) 14/3 SJTW
(20 AMP) 12/3 SJTW
YELLOW CORD, BLACK BODY
BLACK PLUG & CONNECTOR
NEMA
PLUG
NEMA
CONNECTOR
15A 125V, Cord Sets
2'
6'
25'
66591-2C
66591-6C
66591-25C
5-15P
5-15R
15A 125V, Cord Set Triple Outlet
3'
66593-3
5-15P
5-15R
15A 125V, Locking Cord Set
3'
66597-3
L5-15P
L5-15R
15A 125V, Power Supply Cord
37'
26591-37C
–
5-15P
15A 240V, Power Supply Cord
35'
26592-E
–
6-15P
20A 125V, Cord Sets
3'
66891-3
5-20P
5-20R
20A 125V, Locking Cord Set
3'
66897-3
L5-20P
L5-20R
20A 125V, Power Supply Cord
37'
36591-37C
–
5-20P
20A 240V, Power Supply Cord
F
5
35'
36592-E
–
6-20P
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
NOM
C22.2
www.leviton.com
15A 125V;20A125V
Manual Reset GFCI Cord Sets
1 YEAR LIMITED
ELECTRICAL
DIELECTRIC
VOLTAGE
CURRENT
INTERR.
Withstands
1500V
per
UL 498
10kA
TERMINAL
I.D.
TERMINAL
ACCOMMODATION
Brass, hot
TRIP LEVEL
5±1 mA
STANDARDS & CERTIFICATIONS
MECHANICAL
TEMP.
RISE
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
Not Applicable
Grounding
Silver, neutral
PRODUCT
I.D.
Ratings
permanently
marked
on device
NEMA ANSI
WD-6 C-73
UL
UL
943 Fed Spec
Class A
Listed
& 498
WC-596
ENVIRONMENTAL
–
CSA
NOM
C22.2
#LR-57811 #057
AC HORSEPOWER RATINGS
FLAMMABILITY
OPERATING TEMP.
Rated V-2 per UL 94
-35C to 66C
1.5
Manual reset units (yellow body) will not automatically reset
after power interruption; the reset button must be pushed in.
69591
Manual Reset GFCI Cord Sets
69891
FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations.
LENGTH
GFCI CORD SET AUTOMATIC RESET
(15 AMP) 14/3 SJTW
(20 AMP) 12/3 SJTW
YELLOW CORD, BLACK BODY
BLACK PLUG & CONNECTOR
NEMA
PLUG
NEMA
CONNECTOR
15A 125V, Cord Sets
3'
25'
69591-3
69591-25
5-15P
5-15R
15A 125V, Cord Set Triple Outlet
3'
69593-3
5-15P
5-15R
15A 125V, W/ Wetguard Plug & Connector Cord Set
3'
25'
69591-W3
69591-W25
5-15P
5-15R
5-20P
5-20R
20A 125V, Cord Set
3'
69891-3
20A 125V, Locking Cord Set
3'
69897-3
(Available as Special Order Only)
L5-20P
20A 125V, w/ Wetguard Plug & Connector Cord Set
3'
–
L5-20R
69891-W3
5-20R
1.78 (45.2 mm)
5-20P
6.70 (170.2 mm)
36.0 (914.4 mm)
6.70 (170.2 mm)
(9.32 ± 2 mm)
0.63 (15.6 mm)
2.50 (63.5 mm)
15A AUTO GFCI CORD
66591-2C - on page F4
To learn more about Leviton devices or for answers to technical questions call our Techline at
2.50 (63.5 mm)
TEST
RESET
RESET
1.63 (41.1 mm)
TEST BEFORE EACH USE
TEST
FOLLOW DIRECTIONS
0.367± 0.07
MANUAL RESET GFCI CORD
69897-3
1-800-824-3005 or visit us at:
www.leviton.com
F
6
50A 125/250V
Power Center "THE BOX" & Power Cords
Temporary Portable Power Distribution Center/GFCI & Power Cords
ELECTRICAL
DIELECTRIC
VOLTAGE
CURRENT
INTERR.
Withstands
1500V
per
UL 498
10kA
1 YEAR LIMITED
STANDARDS & CERTIFICATIONS
MECHANICAL
TEMP.
RISE
TERMINAL
TERMINAL
I.D.
ACCOMMODATION
Brass, hot
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
TRIP LEVEL
5±1 mA
Not Applicable
Grounding
NEMA ANSI
WD-6 C-73
PRODUCT
I.D.
Ratings &
NEMA I.D.
permanently
marked on device
White,neutral
UL
UL
943 Fed Spec
Class A
Listed
& 498
WC-596
–
ENVIRONMENTAL
FLAMMABILITY
Rated V-2 per UL 94
CSA
#LR-57811 #057
OSHA
OPERATING TEMP.
"The Box" Meets Regulation 20, Part 1926,
Subpart K Standards
-35C to 66C
Power Distribution Box - All Locking Receptacles
6 GFCI Protected 20A 125V Locking Receptacles;
1 GFCI Protected Locking Receptacle 30A 250V
BOX
COLOR
POWER
DISTRIBUTION BOX
POWER INLET
NON-NEMA
POWER OUTLET
NON-NEMA
6 NEMAGFCI PROTECTED 1 NEMAGFCI PROTECTED
RECEPTACLES
RECEPTACLE
50A 125/250V, NON-NEMA, NEMA L5-20R AND L6-30R
Y
Y
Yellow
PB101-SGF
X
X
EQ GR
EQ GR
W
W
Non-NEMA
Non-NEMA
L5-20R
L6-30R
Power Distribution Box - Straight Blade Receptacles & 1 Locking Receptacle
6 GFCI Protected 20A/125V Straight Blade Receptacles;
1 GFCI Protected Locking Receptacle 30A 250V
BOX
COLOR
POWER
DISTRIBUTION BOX
POWER INLET
NON-NEMA
POWER OUTLET
NON-NEMA
6 NEMAGFCI PROTECTED 1 NEMAGFCI PROTECTED
RECEPTACLES
RECEPTACLE
50A 125/250V, NON-NEMA, NEMA 5-20R AND L6-30R
Y
Y
Yellow
PB103-SGF
X
X
EQ GR
EQ GR
W
W
Non-NEMA
Non-NEMA
5-20R
L6-30R
Power Cords
Features Flexible, Abrasion-Resistant Construction Offering Reliable Performance to -31F
LENGTH
FACTORY-ASSEMBLED CORD SETS
BLACK FLEXIBLE CORD w/
YELLOW & WHITE
(3) #6 AWG and (1) #8
WEATHER-RESISTANT PLUG
AWG CONDUCTORS
NON-NEMA
YELLOW & WHITE
WEATHER-RESISTANT CONNECTOR
NON-NEMA
50A 125/250V, NON-NEMA
Y
50'
100'
†Consult
22
16.00
in.
IST
DIS
KRS-A9519
KUS-A9519
Y
X
EQ GR
X
W
EQ GR
W
NON-NEMA†
NON-NEMA†
Factory for Other Configurations.
125V/20A
GFCI
for
30A-250V
RECEPTACLE
125V/20A
in.
125V/20A
125V/20A
UTION
RIB
P
T
ET
12 in.
125V/20
END VIEW 1
SIDE VIEW 1
A
250V/30A
F
7
NOM
C22.2
.50
12 in
in.
Weather Resistant Cover
For 30A Locking Recept.
Circuit Breaker Cover
19
.
TOP VIEW
END VIEW 2
To learn more about Leviton devices or for answers to technical questions call our Techline at
SIDE VIEW 2
1-800-824-3005 or visit us at:
www.leviton.com
GFCI Accessories
2 YEAR LIMITED
5977-CL
4998-GY
4992
5977-GY
5997-CL
5997-GY
Single-Gang Flush Cover Wallplates
TYPE
MOUNTING POSITION
Vertical
Horizontal
Vertical
Horizontal
Horizontal
Vertical
Horizontal
Horizontal
Vertical
Vertical
FITS
TYPE OF BOX
6196-V
6196
6196-VFS
6196-FS
4990
4992
4996-GY
4996-W
4998-GY
4998-W
Standard
Standard
FS (4 Screws)
FS (4 Screws)
Standard
Standard
Standard
Standard
Standard
Standard
Raintight While-In-Use Covers
TYPE
MOUNTING POSITION
Gray Plastic
Gray Plastic
SINGLE-GANG
FLUSH COVER
Vertical
Vertical Mount w/
Extra Deep Cover
Vertical
Clear Plastic
Clear Plastic
5977-GY
5977-DGY
Clear Plastic
Clear Plastic
Surface-Mounted
5977-CL
Vertical Mount w/
Extra Deep Cover
Horizontal
Horizontal Mount w/
Extra Deep Cover
Horizontal
Horizontal Mount w/
Extra Deep Cover
Gray Plastic
Gray Plastic
FITS
TYPE OF BOX
5977-DCL
Outdoor-Type Boxes
5997-GY
5997-DGY
or Flush-Mounted
Wall Boxes
5997-CL
5997-DCL
GFCI Accessories
Gray Die-Cast Zinc
Gray Die-Cast Zinc
Gray Die-Cast Zinc
Gray Die-Cast Zinc
Gray Die-Cast Zinc
Gray Die-Cast Zinc
Gray Plastic
White Plastic
Gray Plastic
White Plastic
SINGLE-GANG
FLUSH COVER
Combination Receptacle Circuit Tester/GFCI Tester
CATALOG NUMBER
Compact tester checks for correct wiring,
reversed polarity, open ground, open neutral,
open hot, hot and ground reversed, and hot
unwired. Device also evaluates status of GFCI
protection. Selector switch applies 1, 2, 3, and 5
milliamp tests enabling user to check for
leakage current in the GFCI circuit.
6185
6182
Carrying case for receptacle circuit tester and
GFCI tester.
6185
3.30 (83.8 mm)
DESCRIPTION
3.75 (95.6 mm)
6.59 (167.4 mm)
5.46 (138.7 mm)
2.88 (73.2 mm)
Ø0
0.63
63 ((16
(16.0
0 mm))
cord opening
F
Ø 0.25 ((6.4 mm))
padlock opening
5.05 (128.3 mm)
Ø0
0.25
25 ((16
(16.0
0 mm))
cord opening
5977
To learn more about Leviton devices or for answers to technical questions call our Techline at
5997
1-800-824-3005 or visit us at:
www.leviton.com
8
SmartLock® Information
Background on GFCI Safety Issues:
Important safety considerations for any GFCI installation have always included:
• Is it wired properly (line/load reversal)?
• Has it been damaged by voltage surges
or
corrosion so that it will not trip in the
event of a ground fault?
• Is it tested regularly?
SmartLock® Information
Industry-wide efforts to prevent line/load wiring reversals
have never been 100% effective. More importantly, endusers still do not regularly test their GFCI’s. As a result,
GFCI’s damaged by voltage surges or corrosion that may
not operate properly are often reset without any further
testing. Consumers are at risk by continuing to use a
GFCI receptacle that cannot respond to a hazardous
ground fault. This has been a particular concern for public
safety agencies including the U. S. Consumer Product
Safety Commission (CPSC).
Meeting the New 1/1/03 UL Requirements:
Manufacturers must implement changes to address the
major GFCI concern:
Be Smart...Look for the Lock
1) Diagnostic Indication for Miswiring- In brief, if GFCI’s
are miswired with a line/load reversal, there must be a
diagnostic indication. Leviton’s SmartLock® already conforms to this because it cannot be reset if there is a line/load reversal.
2) Surge Immunity - Since surges are a leading cause of GFCI failures, increased surge immunity is required.
Corrosion Resistance - New criteria for corrosion resistance help to eliminate another cause of GFCI failures.
3) False Tripping - New requirements will also help ensure that GFCI’s are more resistant to false tripping caused by electrical
noise.
Leviton’s SmartLock will meet or exceed all the new corrosion resistance and noise immunity requirements.
Leviton’s Unique Position:
UL wants GFCI manufacturers to provide more protection for the internal GFCI circuitry and Leviton fully supports this effort.
However, what will happen when a GFCI is damaged despite its improved resistance to surges and corrosion? Under the new
requirements, the GFCI can still be reset after it’s damaged.
Leviton developed the product that goes further: SmartLock. If for any reason SmartLock is damaged and can no longer provide
F
9
ground fault protection, it cannot be reset. Leviton invented this patented lockout action and is currently the only GFCI manufacturer offering this feature and the first to manufacture a GFCI that is fully compliant with the new UL requirements for 2003.
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com