Hubbell Wiring

advertisement
Section K
Ground Fault Products
Index
Extra Heavy Duty
Industrial GFCIs
ProductPage
Hubbell Self Test GFCI Patented Technology and Features . . . . . . . . . . . K-2
Extra Heavy Duty Industrial and Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant. . . . . . . . . . . . . . . . . . . . . . . . . K-3
Commercial Grade GFCI Receptacles
Tamper-Resistant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K-4
Standard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K-5
Hospital Grade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K-6
Tamper-Resistant and Weather Resistant. . . . . . . . . . . . . . . . . . . . . . . . . K-7
Weather Resistant Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K-8
Commercial GFCIs
SNAPConnect® Commercial Grade GFCI Receptacles. . . . . . . . . . . . . . . K-9
GFCI Sensing Module, 50A Maximum Rating - NEMA Type 4X . . . . . . . K-10
Straight Blade Portable GFCI Plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K-11
Circuit Guard® Plug-In Portable GFCI and GFCI Tester. . . . . . . . . . . . . . K-12
Portable GFCI Line Cords
Industrial Grade, Automatic and Manual Set. . . . . . . . . . . . . . . . . . . . . . K-14
Commercial Grade, Automatic and Manual Set . . . . . . . . . . . . . . . . . . . K-15
Multiple Outlet Portable GFCI and GFCI Module . . . . . . . . . . . . . . . . . . K-16
Hard Wired 30 Ampere GFCI - NEMA Type 4X . . . . . . . . . . . . . . . . . . . . . K-17
GFCI Sensing Module
and Circuit Breaker
Portable 30 Ampere GFCI - NEMA Type 4X. . . . . . . . . . . . . . . . . . . . . . . . K-18
Portable GFCI Products
www.hubbell-wiring.com
®
Wiring Device-Kellems
K-1
Ground Fault Products
Hubbell Self Test GFCI Patented Technology and Features
Night Light
Isolated Ground
AUTOGUARD® Self Test Technology 1st introduced by Hubbell over 10 years ago!
…self test monitoring now required in 2015 UL 943 GFCI Safety Standard…
Hubbell Self Test GFCI Patented Technology
Hubbell AUTOGUARD® GFCI receptacles
continually test and monitor for “people protection
capability” automatically. This patented safety
feature includes disconnecting power to the
receptacle if critical components are damaged and
GFCI protection is lost. GFCI auto-monitoring is
conducted continuously within every 30 seconds.
Also, clear visual indicators are provided on
the device face representing power status, trip
condition, ground fault condition and end of life
status. In addition, for added safety, power will be
denied to the receptacle face if reverse wiring of
line and load was to occur.
Hospital Grade
Combo Switch/GFCI
Audible Alarm
Hubbell Self Test Patented Technology
UL (Underwriters Laboratory) now requires all manufacturers to provide self test monitoring capability effective
June 29, 2015. When was the last time you tested a GFCI receptacle? Industry studies indicate only a very
small number of installations are actually being tested as is recommended by the manufacturer and UL. This is
the fundamental reason this new revision has been incorporated into UL 943 standard for 2015.
Each GFR must automatically
monitor GFCI functionality
periodically
If the unit can no longer provide
GFCI protection, it must comply
with the following
Reverse line and load miswire
function – (repeated)
Automatically test within (5)
seconds of power to line and load
terminals; periodically means every
(3) hours or less.
Deny Power (trip with the inability to
reset); if unit does reset it is subject
to the next auto-monitoring test
cycle.
If the line conductor is wired to
the load terminal, power to the
receptacle face will be denied. This
includes both the initial installation
and any subsequent reinstallations.
Visual and/or audible indication that
it no longer can provide protection.
Features
• Patented AUTOGUARD® Technology — Continuous Self Test
Tamper- Resistant
SNAPConnect®
functionality and disconnects power to receptacle if critical
components are damaged and GFCI protection is lost
• Federal Communications Commission Part 15 — Compliant for
radiated and conducted emissions
• Thermoplastic Nylon Housing — High Impact and Ultraviolet
Resistant construction provides resilience in harsh environments
• Clear Visual Indication of GFR Status — LED Indicating Lights:
Green LED (power to the device)
Red LED (trip condition/ground fault condition)
Flashing Red LED (end of life)
• Internal Back Wiring Clamp and Guide Pocket — Quick and
dependable termination
• Protection Against Line and Load Reversal — No power to the face
or downstream receptacles if device is miswired
Weather Resistant
• Installation Ease, Lower Labor Cost — With auto-grounding clip,
K-2
captive mounting screws and single tab “breakoff” ears and full
“breakoff” for OEM raised covers
• Night Light Option — Light sensor controls for automatic "ON/OFF"
and custom dual lens for optimum light output
GFRST15WNL
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant
GFR5362SGI
Meets UL Standard 943
Class A GFCI
Features
10kA Short Circuit Current Rating
Limits improper access to energized contacts
• Exclusive patented tamper-resistant protection through
switching technology
• Continually tests and monitors for people protection automatically
• Patented self test diagnostics
Power indication
• Steady “ON” GREEN LED provides indication of power
Ground fault indicator
• Steady “ON” RED LED provides visual indication of a
ground fault condition; flashing red indicates device has
lost capability to provide protection
No power at face if reverse wired
• Open circuit condition eliminates false assumption of
protection at face
Durable face with V-0 flammability rating
• Polyester face cover
AUTOGUARD® Self Test GFCI Receptacles
Tamper-Resistant and Weather Resistant
Description
Flush, polyester face,
back and side wired,
multiple drive screws.
Flush, polyester face,
back and side wired,
multiple drive screws.
Rating
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Color
Standard
Hospital Grade
Black
Brown
Gray
Ivory
Red
White
GFR5262SGBK
GFR5262SG
GFR5262SGGY
GFR5262SGI
GFR5262SGR
GFR5262SGW
GFR8200SGBK
GFR8200SG
GFR8200SGGY
GFR8200SGI
GFR8200SGR
GFR8200SGW
Black
Brown
Gray
Ivory
Red
White
GFR5362SGBK
GFR5362SG
GFR5362SGGY
GFR5362SGI
GFR5362SGR
GFR5362SGW
GFR8300SGBK
GFR8300SG
GFR8300SGGY
GFR8300SGI
GFR8300SGR
GFR8300SGW
Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of the possibility of power interruption. All
GFCI receptacles listed above are furnished with both a matching color nylon wallplate, and a SS26 302/304 super stainless steel wallplate. 20 amp feed-through capability.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
GFCI Receptacle Specifications per GFCI Products Listed (Pages K-2 to K-9)
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Listings and Standards
Codes
4 to 6 mA.
.025 second nominal.
60 Hz.
120V AC +10% - 15% (102V to 132V).
15A/20A, 20A Feed Thru.
10,000A.
-35°C to 66°C or -30°F to 150°F.
95%.
Meets UL498 for receptacles, UL943 Class A for GFCIs UL File E41978.
CSA Certified.
Meets all NEC® and CEC requirements. NEMA WD-6 ANSI 73.
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
www.hubbell-wiring.com
®
Wiring Device-Kellems
K-3
Ground Fault Products
Commercial Tamper-Resistant GFCI Receptacles
Meets UL Standard 943
Class A GFCI
Features
• Patented shutter design for tamper-resistant
protection
• Compliant with NEC® 406.12 and NEC® 517-18(c)
• Patented AUTOGUARD® self test technology
includes disconnecting power to the receptacle
if critical components are damaged and GFCI
protection is lost
• Alarm version provides audible notification of a
trip condition
GFTRST20
Tamper-Resistant
Rating
Color
Standard
Night Light
Two LED Night Lights
Alarm
Combination Switch
15A 120V Switch
Standard 3-Pack
Three Devices per Pack
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTRST15AL
GFTRST15BK
GFTRST15
GFTRST15GY
GFTRST15I
GFTRST15LA
GFTRST15R
GFTRST15W
GFTRST15ALNL
GFTRST15BKNL
GFTRST15NL
GFTRST15GYNL
GFTRST15INL
GFTRST15LANL
GFTRST15RNL
GFTRST15WNL
GFTRST15ALB
GFTRST15BKB
GFTRST15B
GFTRST15GYB
GFTRST15IB
GFTRST15LAB
GFTRST15RB
GFTRST15WB
—
—
—
—
GFSPST15I
GFSPST15LA
—
GFSPST15W
—
—
—
—
GFTRST15I3
GFTRST15LA3
—
GFTRST15W3
20A 125V
NEMA 5-20R
UL CSA
1 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTRST20AL
GFTRST20BK
GFTRST20
GFTRST20GY
GFTRST20I
GFTRST20LA
GFTRST20R
GFTRST20W
GFTRST20ALNL
GFTRST20BKNL
GFTRST20NL
GFTRST20GYNL
GFTRST20INL
GFTRST20LANL
GFTRST20RNL
GFTRST20WNL
GFTRST20ALB
GFTRST20BKB
GFTRST20B
GFTRST20GYB
GFTRST20IB
GFTRST20LAB
GFTRST20RB
GFTRST20WB
Hospital Grade •
Tamper-Resistant
Rating
Color
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTRST82ALNL
GFTRST82BKNL
GFTRST82NL
GFTRST82GYNL
GFTRST82INL
GFTRST82LANL
GFTRST82RNL
GFTRST82WNL
GFTRST82ALB
GFTRST82BKB
GFTRST82B
GFTRST82GYB
GFTRST82IB
GFTRST82LAB
GFTRST82RB
GFTRST82WB
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTRST83ALNL
GFTRST83BKNL
GFTRST83NL
GFTRST83GYNL
GFTRST83INL
GFTRST83LANL
GFTRST83RNL
GFTRST83WNL
GFTRST83ALB
GFTRST83BKB
GFTRST83B
GFTRST83GYB
GFTRST83IB
GFTRST83LAB
GFTRST83RB
GFTRST83WB
K-4
—
—
—
—
GFTRST20I3
GFTRST20LA3
—
GFTRST20W3
Product Dimensions Inches (mm)
Night Light
Two LED Night Lights
20A 125V
NEMA 5-20R
UL CSA
1 HP
—
—
—
—
—
—
—
—
Alarm
®
GFCI Receptacle
A
3.27 (83.1)
B
2.75 (69.8)
C
1.75 (44.5)
D
1.47 (37.4)
E
1.10 (27.9)
Wiring Device-Kellems
E
A
B
C
D
www.hubbell-wiring.com
Ground Fault Products
Commercial Standard GFCI Receptacles
Meets UL Standard 943
Class A GFCI
Features
• Patented AUTOGUARD® self test technology
includes disconnecting power to the receptacle
if critical components are damaged and GFCI
protection is lost
• Internal back wiring clamp and guide for quick
and secure termination
• Night light option includes light sensor controls
for automatic on and off, custom dual lens for
optimum light output
GFRST15WNL
Standard
Rating
Color
Standard
Night Light
Two LED Night Lights Alarm
Assembled in USA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST15AL
GFRST15BK
GFRST15
GFRST15GY
GFRST15I
GFRST15LA
GFRST15R
GFRST15W
GFRST15ALNL
GFRST15BKNL
GFRST15NL
GFRST15GYNL
GFRST15INL
GFRST15LANL
GFRST15RNL
GFRST15WNL
GFRST15ALB
GFRST15BKB
GFRST15B
GFRST15GYB
GFRST15IB
GFRST15LAB
GFRST15RB
GFRST15WZB
GFRST15ALU
GFRST15BKU
GFRST15U
GFRST15GYU
GFRST15IU
GFRST15LAU
GFRST15RU
GFRST15WU
20A 125V
NEMA 5-20R
UL CSA
1 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST20AL
GFRST20BK
GFRST20
GFRST20GY
GFRST20I
GFRST20LA
GFRST20R
GFRST20W
GFRST20ALNL
GFRST20BKNL
GFRST20NL
GFRST20GYNL
GFRST20INL
GFRST20LANL
GFRST20RNL
GFRST20WNL
GFRST20ALB
GFRST20BKB
GFRST20B
GFRST20GYB
GFRST20IB
GFRST20LAB
GFRST20RB
GFRST20WB
GFRST20ALU
GFRST20BKU
GFRST20U
GFRST20GYU
GFRST20IU
GFRST20LAU
GFRST20RU
GFRST20WU
Standard
SNAPConnect®
Blank Face
Available in 20A Only
—
—
—
—
—
—
—
—
Standard 3-Pack
Three Devices per Pack
—
—
—
—
GFRST15I3
GFRST15LA3
—
GFRST15W3
GFBFST20AL
GFBFST20BK
GFBFST20
GFBFST20GY
GFBFST20I
GFBFST20LA
GFBFST20R
GFBFST20W
—
—
—
—
GFRST20I3
GFRST20LA3
—
GFRST20W3
Right Angle Pigtailed Terminal
Rating
Color
Standard
Description
Type
Catalog Number
GFRST15SNAPAL
GFRST15SNAPBK
GFRST15SNAP
GFRST15SNAPGY
GFRST15SNAPI
GFRST15SNAPLA
GFRST15SNAPR
GFRST15SNAPW
Clear right angle terminal with 6 inch leads,
600V, #12 AWG THHN/THWN-2,
Polycarbonate housing material.
Solid
Stranded
SNAP1RA
SNAP2RA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
20A 125V
NEMA 5-20R
UL CSA
1 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST20SNAPAL
GFRST20SNAPBK
GFRST20SNAP
GFRST20SNAPGY
GFRST20SNAPI
GFRST20SNAPLA
GFRST20SNAPR
GFRST20SNAPW
www.hubbell-wiring.com
®
Wiring Device-Kellems
K-5
Ground Fault Products
Commercial Standard Hospital Grade GFCI Receptacles
Meets UL Standard 943
Class A GFCI
Features
• Fed. Spec UL Listed, Hospital Grade
• Green power indicator and red trip indicator
• Patented AUTOGUARD® self test technology
• Flush, nylon face, back and side wired,
multiple drive screws, self-grounding staple.
GFRST82WNL
Hospital Grade •
Rating
Color
Standard
Night Light
Two LED Night Lights
Alarm
Assembled in USA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST82AL
GFRST82BK
GFRST82
GFRST82GY
GFRST82I
GFRST82LA
GFRST82R
GFRST82W
GFRST82ALNL
GFRST82BKNL
GFRST82NL
GFRST82GYNL
GFRST82INL
GFRST82LANL
GFRST82RNL
GFRST82WNL
GFRST82ALB
GFRST82BKB
GFRST82B
GFRST82GYB
GFRST82IB
GFRST82LAB
GFRST82RB
GFRST82WB
GFRST82ALU
GFRST82BKU
GFRST82U
GFRST82GYU
GFRST82IU
GFRST82LAU
GFRST82RU
GFRST82WU
20A 125V
NEMA 5-20R
UL CSA
1 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST83AL
GFRST83BK
GFRST83
GFRST83GY
GFRST83I
GFRST83LA
GFRST83R
GFRST83W
GFRST83ALNL
GFRST83BKNL
GFRST83NL
GFRST83GYNL
GFRST83INL
GFRST83LANL
GFRST83RNL
GFRST83WNL
GFRST83ALB
GFRST83BKB
GFRST83B
GFRST83GYB
GFRST83IB
GFRST83LAB
GFRST83RB
GFRST83WB
GFRST83ALU
GFRST83BKU
GFRST83U
GFRST83GYU
GFRST83IU
GFRST83LAU
GFRST83RU
GFRST83WU
Hospital Grade •
SNAPConnect®
Right Angle Pigtailed Terminal
Rating
Color
Standard
Description
Type
Catalog Number
GFRST82SNAPAL
GFRST82SNAPBK
GFRST82SNAP
GFRST82SNAPGY
GFRST82SNAPI
GFRST82SNAPLA
GFRST82SNAPR
GFRST82SNAPW
Clear right angle terminal with 6 inch leads,
600V, #12 AWG THHN/THWN-2,
Polycarbonate housing material.
Solid
Stranded
SNAP1RA
SNAP2RA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
20A 125V
NEMA 5-20R
UL CSA
1 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFRST83SNAPAL
GFRST83SNAPBK
GFRST83SNAP
GFRST83SNAPGY
GFRST83SNAPI
GFRST83SNAPLA
GFRST83SNAPR
GFRST83SNAPW
K-6
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
Commercial Tamper-Resistant and Weather Resistant
GFCI Receptacles
Meets UL Standard 943
Class A GFCI
Features
• Patented shutter design for tamper-resistant
protection
• Meets NEC requirements for TR (517-18c) and
WR (406.9), UV and corrosion resistance for
harsh and damp applications
• Patented AUTOGUARD® self test technology
• Protects against line and load reversal, no power
to the face or downstream if device is miswired
GFTWRST20WIG
Tamper-Resistant
Weather Resistant
Rating
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Color
Standard
Assembled in USA
Isolated Ground
SNAPConnect®
Right Angle Pigtailed Terminal
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTWRST15AL
GFTWRST15BK
GFTWRST15
GFTWRST15GY
GFTWRST15I
GFTWRST15LA
GFTWRST15R
GFTWRST15W
GFTWRST15ALU
GFTWRST15BKU
GFTWRST15U
GFTWRST15GYU
GFTWRST15IU
GFTWRST15LAU
GFTWRST15RU
GFTWRST15WU
GFTWRST15ALIG
GFTWRST15BKIG
GFTWRST15IG
GFTWRST15GYIG
GFTWRST15IIG
GFTWRST15LAIG
GFTWRST15RIG
GFTWRST15WIG
GFTWRST15SNAPAL
GFTWRST15SNAPBK
GFTWRST15SNAP
GFTWRST15SNAPGY
GFTWRST15SNAPI
GFTWRST15SNAPLA
GFTWRST15SNAPR
GFTWRST15SNAPW
Clear right angle terminal
with 6 inch leads,
600V, #12 AWG THHN/
THWN-2, Polycarbonate
housing material.
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTWRST20AL
GFTWRST20BK
GFTWRST20
GFTWRST20GY
GFTWRST20I
GFTWRST20LA
GFTWRST20R
GFTWRST20W
GFTWRST20ALU
GFTWRST20BKU
GFTWRST20U
GFTWRST20GYU
GFTWRST20IU
GFTWRST20LAU
GFTWRST20RU
GFTWRST20WU
GFTWRST20ALIG
GFTWRST20BKIG
GFTWRST20IG
GFTWRST20GYIG
GFTWRST20IIG
GFTWRST20LAIG
GFTWRST20RIG
GFTWRST20WIG
GFTWRST20SNAPAL
GFTWRST20SNAPBK
GFTWRST20SNAP
GFTWRST20SNAPGY
GFTWRST20SNAPI
GFTWRST20SNAPLA
GFTWRST20SNAPR
GFTWRST20SNAPW
Solid
Stranded
SNAP1RA
SNAP2RA
Hospital Grade •
Tamper-Resistant
Weather Resistant
Rating
Color
Standard
Assembled in USA
Isolated Ground
SNAPConnect®
Right Angle Pigtailed Terminal
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTWRST82AL
GFTWRST82BK
GFTWRST82
GFTWRST82GY
GFTWRST82I
GFTWRST82LA
GFTWRST82R
GFTWRST82W
GFTWRST82ALU
GFTWRST82BKU
GFTWRST82U
GFTWRST82GYU
GFTWRST82IU
GFTWRST82LAU
GFTWRST82RU
GFTWRST82WU
GFTWRST82ALIG
GFTWRST82BKIG
GFTWRST82IG
GFTWRST82GYIG
GFTWRST82IIG
GFTWRST82LAIG
GFTWRST82RIG
GFTWRST82WIG
GFTWRST82SNAPAL
GFTWRST82SNAPBK
GFTWRST82SNAP
GFTWRST82SNAPGY
GFTWRST82SNAPI
GFTWRST82SNAPLA
GFTWRST82SNAPR
GFTWRST82SNAPW
Clear right angle terminal
with 6 inch leads,
600V, #12 AWG THHN/
THWN-2, Polycarbonate
housing material.
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTWRST83AL
GFTWRST83BK
GFTWRST83
GFTWRST83GY
GFTWRST83I
GFTWRST83LA
GFTWRST83R
GFTWRST83W
GFTWRST83ALU
GFTWRST83BKU
GFTWRST83U
GFTWRST83GYU
GFTWRST83IU
GFTWRST83LAU
GFTWRST83RU
GFTWRST83WU
GFTWRST83ALIG
GFTWRST83BKIG
GFTWRST83IG
GFTWRST83GYIG
GFTWRST83IIG
GFTWRST83LAIG
GFTWRST83RIG
GFTWRST83WIG
GFTWRST83SNAPAL
GFTWRST83SNAPBK
GFTWRST83SNAP
GFTWRST83SNAPGY
GFTWRST83SNAPI
GFTWRST83SNAPLA
GFTWRST83SNAPR
GFTWRST83SNAPW
20A 125V
NEMA 5-20R
UL CSA
1 HP
www.hubbell-wiring.com
®
Wiring Device-Kellems
Solid
Stranded
SNAP1RA
SNAP2RA
K-7
Ground Fault Products
Commercial Weather Resistant GFCI Receptacles
Meets UL Standard 943
Class A GFCI
Features
• Patented AUTOGUARD® self test technology
• Meets NEC requirements for weather resistance
(406.9), UV and corrosion resistance for harsh
and damp applications
• Protects against line and load reversal, no power
to the face or downstream if device is miswired
GFWRST15W
Weather Resistant
Rating
Color
Standard
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
Almond
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFWRST15AL
GFWRST15BK
GFWRST15
GFWRST15GY
GFWRST15I
GFWRST15LA
GFWRST15R
GFWRST15W
Rating
Standard
20A 125V
NEMA 5-20R
UL CSA
1 HP
GFWRST20AL
GFWRST20BK
GFWRST20
GFWRST20GY
GFWRST20I
GFWRST20LA
GFWRST20R
GFWRST20W
Common Questions and Answers
Q: Why are ground fault receptacles changing?
A: Underwriters Laboratory per revised Standard 943 has published new self test monitoring requirements that apply to all
permanently installed GFCI products, effective June 29, 2015.
Q: What is the primary benefit from these changes?
A: Every GFR must now test itself for the ability to provide GFCI protection. Industry studies show installed ground fault
receptacles are not being tested as required by the end user (minimum monthly).
Q: Can I continue to use current generation GFCI receptacles after June 28th?
A: Absolutely, the current Hubbell GFCI receptacles can no longer be produced after June 28, 2015. However, these devices
produced prior to June 28th, can be sold by manufacturers and distributors until their inventories are depleted. There is no
time limitation on use of this product.
Q: What is different about this new version?
A: A power denial feature has been added to this next generation of self test GFR product. If critical components are damaged
and GFCI protection is lost, power to the receptacle will be disconnected.
Q: What types of indicators do the AUTOGUARD® ground fault receptacles have?
A: Every GFR includes a solid green LED to indicate power to the face, a solid red LED for a tripped condition and
a flashing red LED to indicate end of life when the unit should be replaced.
Q: How does the Alarm version function?
A: The Alarm GFR includes all LED indicators that are in the standard product. In addition, an audible alarm will sound when
either the unit trips and/or is in end of life. A “silencing feature” is provided on the face of the device to turn off as needed.
K-8
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
SNAPConnect® Commercial Grade GFCI Receptacles
Meets UL Standard 943
Class A GFCI
No Special Tester Required
.085 inch keyhole accepts the
probe points found on the most
common voltage testers and
digital multi-meters
Audible SNAP, indicates solid connection
•Secure, easy grip latch
Inspection of power contacts
•Clear terminal housing
•No exposed metal
Requires minimal box space
•Compact size
•Clean finished look
Installation ease
•Self-grounding staple
SNAP1RA
GFRST20SNAPI
Labor Savings Feature!
Save one Minute!
Rough-in the SNAPConnect®
terminal instead of pigtails.
www.hubbell-wiring.com
Save Over Three Minutes!
Remove protective packaging
and SNAPConnect® device to
the circuit.
®
Complete Trim-Out
in Less Than One Minute!
Secure mounting screws, attach
wallplate, job complete.
Wiring Device-Kellems
K-9
Ground Fault Products
GFCI Sensing Module, 50A Maximum Rating - NEMA Type 4X
Typical Applications Include:
Power Generators, Spas, High Pressure Washers, Power Centers, Refineries and Mobile Power.
The sensing module functions interdependently with a magnetic branch circuit breaker. The module monitors the electrical
circuit by use of an external differential current transformer. No direct load is present at the module. In the event of a ground
fault, the load is interrupted by way of the hydraulic magnetic circuit breaker utilizing a shunt trip coil.
This line of Sensing Modules is rated from 1 to 50 Amps and circuit current-carrying conductors from 1 to 3 poles.
Product is available with an automatic or manual “safe start” reset feature. The enclosure, when mounted with the supplied
gasket, achieves a UL NEMA Type 4X Rating. This module and breaker system is ideal for portable generator integration
protecting all outlets on a generator. This system meets the proposed requirements for generators Underwriters Laboratory
Standard 2201. UL/cUL 943 Listed, Class A 4-6mA trip level and UL 1053 Compliant.
GFCI Sensing Module – 50A Maximum
Description
Catalog Number
120V AC Sensing Module Auto
GFSM120A
120V AC Sensing Module Manual
GFSM120M
240V AC Sensing Module Auto
GFSM240A
240V AC Sensing Module Manual
GFSM240M
GFCI Sensing Module Circuit Breakers
Catalog Number Configurator
GFSM120M
Ground Fault Sensing
Module Circuit Breaker
A/C Voltage
Amperage
Number
of Poles
120
120
GFSMCB
GFSMCB120401P
Wiring Schematics
CIRCUIT
BREAKER
LOAD
PART #
AUTO GFSM120A
MAUUAL GFSM120M
120VAC GFCI
SENSING
MODULE
NO
C
H
GFSM240A or M
GFSM120A or M
120/240
3
GFSM120A or M
GFSMCB120401P:
GFSMCB240502P:
GFSMCB120240203P:
Current carrying leads must
be twisted as they go through
the sensing module.
120V, 40A, 1 Pole
240V, 50A, 2 Pole
120/240V, 20A, 3 Pole
240VAC GFCI
SENSING
MODULE
GFSMCB120240xx3P
ORANGE
SHUNT
JUMPER
L1
LOAD
LOAD--->
N
NO
C
GROUND
®
120VAC GFCI
SENSING
MODULE
LOAD--->
L2
L1
N
120/
240V AC
IN
SINGLE PHASE 240VAC (L1, L2, GRND)
G
Wiring Device-Kellems
CIRCUIT
BREAKER
ORANGE
SHUNT
JUMPER
L2
LOAD
PART #
AUTO GFSM120A
MAUUAL GFSM120M
LINE
RED
BLACK
YELLOW (SHUNT)
SINGLE PHASE 120VAC (HOT, NEUTRAL, GRND)
Current carrying leads must
be twisted as they go through
the sensing module.
L2
L1
L2
240V AC
IN
WHITE
BLACK
YELLOW (SHUNT)
K-10
CIRCUIT
BREAKER
PART #
AUTO GFSM240A
MAUUAL GFSM240M
120V AC
IN
GROUND
GFSM120A or M
2
1 to 50
GFSMCB240xx2P
ORANGE
SHUNT
JUMPER
LINE
H
N
2
120/240
GFSMCB120xx1P
Current carrying leads must
be twisted as they go through
the sensing module.
GFSM120A or M
2
240
Example Catalog Numbers:
Sensing Module Required
1
NO
C
L1
LOAD--->
LINE
N
WHITE
BLACK
YELLOW (SHUNT)
SPLIT PHASE 120/240VAC (L1, L2, N, GRND)
G
GROUND
G
www.hubbell-wiring.com
Ground Fault Products
Straight Blade Portable GFCI Plugs
15 Ampere, 120 Volts AC, 2 Pole, 3 Wire Grounding
Circuit Guard® Wired On Industrial Portable GFCI Plug
Description
Rating
Catalog Number
GFCI plug, manual set, black.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP5266C
GFCI plug, manual set, yellow.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP5266CY
GFCI plug with 1 foot line cord,
manual set, yellow, with
connector body.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P, NEMA 5-15R.
GFP1C
Circuit Guard® Wired On Commercial Portable GFCI Plug
Description
Rating
Catalog Number
GFCI plug, automatic set
field wireable, black.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP515A
GFCI plug, manual set
field wireable, black.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP515M
GFP5266CY
Specifications
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Input
Cord Range
Cord Type: Length (GFP1C)
Power “ON” Indication
Listings
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized material. UL 94V-0 flammability classification.
NEMA 5-15P.
16/3 – 12/3 Type SJ, 18/3 – 12/3 Type S.
14/3 Type SJTW-A (UL), SJTW (CSA); 1 foot; NEMA 5-15R.
Indicator light.
Meets UL943 Class A Listed, CSA Certified.
Meets all NEC® and CEC requirements.
GFP515A
Dimensions
GFP5266C Series
1.60"
(40.6)
GFP515 Series
.81"
(20.5)
4.95"
(125.7)
2.21"
(56.1)
1.35"
(34.3)
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
www.hubbell-wiring.com
Dimensions in Inches (mm)
®
Wiring Device-Kellems
K-11
Ground Fault Products
Circuit Guard® Plug-In Portable GFCI and GFCI Tester
15 Ampere, 120 Volts AC, 2 Pole, 3 Wire Grounding
Circuit Guard® Plug-In Portable GFCI
Description
Rating
Catalog Number
Three outlet plug-in.
15A, 120V AC
GFP315A
Specifications
GFP315A
GFP315A
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Input
Output
Fault Indication
Center Screw
Listings and Standards
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact ABS.
NEMA 5-15P.
3 NEMA 5-15R.
Indicator light.
For optional permanent mounting.
Meets UL498 for receptacles, UL943 Class A for GFCIs UL File E41978,
CSA Certified.
Meets all NEC® and CEC requirements.
Codes
GFCI Tester
Description
Rating
Catalog Number
Ground fault tester.
120V AC
GFT2G
•D
esigned to measure the trip level of portable or “wired-in” GFCI’s in a range of 2-7mA. Leakage
level can be adjusted from 2-7mA.
• Ideal for measuring leakage level of GFCI breakers, GFCI portables and GFCI receptacles.
GFT2G
Dimensions
1.50
(38.1)
5.50
(139.7)
FAULT
LIGHT
RESET
TEST
5.83
(148.0)
3.45
(87.6)
Dimensions in Inches (mm)
K-12
.82
(20.8)
1.76
(44.7)
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
Portable GFCI Line Cords
Features and Benefits
Circuit Guard® Set GFCI Line Cord
Portable GFCI Line Cords provide ground fault protection both indoors and out. They interrupt electrical power for equipment
loads when leakage to ground is 4-6 milliamperes. Available in lengths of 18" (45.7 cm), 6' (182.9 cm), and
25' (762 cm). A 15' (457.2 cm) OEM version with stripped leads is also available. They are offered with an Automatic Set
or Manual Set feature to meet your application.
Available in Automatic Set with yellow base or Manual Set with black base.
All-glass circuit board provides
superior moisture immunity
High impact UV stabilized
housing resists dust, sunlight
and chemicals for long life
One-piece flush sealed
keypads for greater
reliability and resistance
to damage due to impact
Heavy-duty molded plug
and connector for reliable
connection
Solid (not formed) plug blades
are crimped and soldered for
a better connection and l
onger life
Bright fault indicator light
provides fault confirmation
from a distance
Watertight GFCI housing for
use in harsh environments
GFP4C15M
Heavy-duty molded strain
relief prevents conductor
strain and resulting failure
www.hubbell-wiring.com
®
Wiring Device-Kellems
K-13
Ground Fault Products
Portable GFCI Line Cords
Industrial Grade, Automatic and Manual Set
IP21
Circuit Guard® Automatic Set
Portable GFCI Line Cords
GFP4C15A
SUITABILITY
15A 120V AC
Description
Catalog Number
18" (45.7 cm) GFCI line cord.
GFP4C15A
6' (182.9 cm) GFCI line cord.
GFP6C15A
25' (762.0 cm) GFCI line cord.
GFP25C15A
15' (457.2 cm) GFCI power supply cord with stripped leads.
GFPOEMA*
Circuit Guard® Manual Set
Portable GFCI Line Cords
15A 120V AC
Description
Catalog Number
18" (45.7 cm) GFCI line cord.
GFP4C15M
–
3' (91.4 cm) GFCI line cord.
GFP25C15A
20A 120V AC
–
GFP3C20M
6' (182.9 cm) GFCI line cord.
GFP6C15M
–
25' (762.0 cm) GFCI line cord.
GFP25C15M
–
–
15' (457.2 cm) GFCI power supply cord with stripped leads.
GFPOEMM*
50' (1524.0 cm) GFCI power supply with Elastogrip®
watertight straight blade.
GFP50C15WM
100' (3048.0 cm) GFCI power supply with Elastogrip®
watertight straight blade.
GFP100C15WM
Note: *Total length is 15' 4.5" (468.6 cm) including leads: green 4.5" (114.3), black and white 3.5" (88.9). Each pre-stripped .375" (9.5).
Circuit Guard® Manual Set
Twist-Lock Portable GFCI Line Cords
15A 120V AC
Description
Catalog Number
3' (91.4 cm) GFCI line cord.
GFP3C15MTL
Automatic Set GFCI
GFP6C15M
Automatically energizes or sets the GFCI for use upon
plug in and after the loss of primary power (power failure
or unplugging the device). After a ground fault condition,
unit must be reset by pushing the reset button. This
feature eliminates the need for unit to be reset each time it
is plugged in or powered up. Ideal for equipment intended
for continuous use where a temporary power failure is
likely and undesirable. Examples are pumps, pressure
washers, portable signs or lighting and engine heaters.
20A 120V AC
GFP3C20MTL
Manual Set GFCI
Requires the GFCI to be manually set for use by pressing
the reset button upon plug in and after loss of primary
power (power failure or unplugging the device). Must
be manually reset after a ground fault condition. Ideal
for applications where operator injury might occur if
equipment were to restart after a power failure. Typical
equipment includes power drills, saws, lathes and grinders.
Straight Blade
Twist-Lock®
Input
15A NEMA 5-15P,
20A NEMA 5-20P.
15A NEMA L5-15P HBL47CM20C,
20A NEMA L5-20P HBL23CM11.
Output
15A NEMA 5-15R (except GFPOEMM),
20A NEMA 5-20R.
15A NEMA L5-15R HBL47CM29C,
20A NEMA L5-20R HBL23CM13.
GFPOEMM
Specifications
Portable GFCI Line Cords
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
GFP3C20MTL
Cord Type
Visual Fault Indication Light On
Listing and Standards
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A/20A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
14/3 SJTW-A (UL), SJTW (CSA). Except GFP3C20M, GFP3C15MTL and
GFP3C20MTL are 12/3 SJTW.
Indicates fault.
Meets UL943 Class A, UL File E41978, CSA Certified.
Meets all NEC® and CEC requirements.
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
K-14
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
Portable GFCI Line Cords
Commercial Grade, Automatic and Manual Set
Circuit Guard® Portable GFCI Single Outlet - 12/3 SJEOW
15A 120V AC
Description
Catalog Number
2' (60.9 cm) GFCI line cord, automatic set.
GFP2CA
2' (60.9 cm) GFCI line cord, manual set.
GFP2CM
25' (762.0 cm) GFCI line cord, automatic set.
GFP25CA
25' (762.0 cm) GFCI line cord, manual set.
GFP25CM
Circuit Guard® Portable GFCI Triple Tap Outlet - 12/3 SJEOW
15A 120V AC
Description
Catalog Number
2' (60.9 cm) GFCI line cord, automatic set.
GFP2TTA
2' (60.9 cm) GFCI line cord, manual set.
GFP2TTM
25' (762.0 cm) GFCI line cord, automatic set.
GFP25TTA
25' (762.0 cm) GFCI line cord, manual set.
GFP25TTM
Circuit Guard® OEM Equipment Integrated Cord Sets - 14/3 SJEOW
15A 120V AC
Description
Catalog Number
15' (457.2 cm) GFCI with flying leads, automatic set.
GFP15LA
15' (457.2 cm) GFCI with flying leads, manual set.
GFP15LM
35' (1066.8 cm) GFCI with flying leads, automatic set.
GFP35LA
35' (1066.8 cm) GFCI with flying leads, manual set.
GFP35LM
15A GFCI In Line GFCI, Single and Triple Tap - 12/3 SJTW
15A 120V AC
Description
Catalog Number
2' (60.9 cm), 5-15 single tap, automatic set.
GFPIL15125A
2' (60.9 cm), 5-15 single tap, manual set.
GFPIL15125M
2' (60.9 cm), 5-15 triple tap, automatic set.
GFPIL15125TRIA
2' (60.9 cm), 5-15 triple tap, manual set.
GFPIL15125TRIM
20A GFCI In Line GFCI, Locking - 12/3 SJTW
20A 120V AC
Description
Catalog Number
2' (60.9 cm), L5-20 locking, automatic set.
GFPIL20125LKA
2' (60.9 cm), L5-20 locking, manual set.
GFPIL20125LKM
20A GFCI In Line GFCI, Locking - 12/3 SJTW
20A 250V AC
Description
Catalog Number
2' (60.9 cm), L6-20 locking, automatic set.
GFPIL20250LKA
2' (60.9 cm), L6-20 locking, manual set.
GFPIL20250LKM
GFP2CA
GFP2TTA
GFP15LA
GFPIL15125TRIM
Specifications
Portable GFCI Line Cords
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Visual Fault Indication Light On
Listing and Standards
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120/250V AC +10% - 15%. Incorporates no voltage release feature.
15A/20A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
Indicates fault.
Meets UL943 Class A, UL File E41978, CSA Certified.
Meets all NEC® and CEC requirements.
GFPIL20125LKA
GFPIL20125LKM
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
www.hubbell-wiring.com
®
Wiring Device-Kellems
K-15
Ground Fault Products
Portable GFCI Line Cords
Multiple Outlet Portable GFCI and GFCI Module
IP21
SUITABILITY
Multiple Outlet Portable GFCI
Description
Rating
Receptacles
Plug
Catalog Number
4 outlet,
manual set, yellow.
15A, 120V AC
(2) Duplex 5-15R
NEMA 5-15P
GFP15M
4 outlet,
manual set, yellow.
20A, 120V AC
(2) Duplex 5-20R
NEMA 5-20P
GFP20M
GFP15M
GFCI Module - UL Type 3R Rated
Description
Rating
Catalog Number
GFCI module,
manual set, yellow.
20A, 120V AC, 60 Hz
GFM20
GFCI module,
auto set, yellow.
20A, 120V AC, 60 Hz
GFM20A
GFM20
Specifications
GFP15M / GFP20M
Trip Level
4 to 6 mA.
Trip Time
.025 sec. nominal.
Frequency
60 Hz.
Voltage
120V AC +10% - 15%.
No voltage release feature.
Maximum Interrupting Capacity
5000A.
Current
15A / 20A.
Operating Temperature
-35°C to 66°C or -30°F to 150°F.
Housing Rating
High-impact, yellow Valox®
with protective lift covers.
Input
5-15P, 15A / 5-20P, 20A. IP21 Suitability.
Output
5-15R(4), 15A / 5-20R(4), 20A.
Power Supply Cord
6' (182.9 cm) STOW-A (STW FT2 CSA).
Mounting Screws
N/A.
Power “ON” Indication
LED indicator light.
Agency Approvals
UL Listed, UL498 for receptacles.
Meets UL943 Class A for GFCI’s.
Codes
Meets all NEC® and CEC requirements.
GFM20 / GFM20A
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% - 15%.
No voltage release feature.
5000A.
20A / 20A Feed-through.
-35°C to 66°C or -30°F to 150°F.
High-impact, UV stabilized, rigid PVC.
UL 94V-0 flammability classification.
UL Type 3R Rated.
#12 AWG stranded conductors (black/white/green).
#12 AWG stranded conductors (red/gray).
N/A.
Self-tapping, combination, #6-32.
LED indicator light.
UL Listed, CSA Certified.
Meets UL943 Class A for GFCI’s.
Meets all NEC® and CEC requirements.
Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
K-16
®
Wiring Device-Kellems
www.hubbell-wiring.com
Ground Fault Products
Hard Wired 30 Ampere GFCI - NEMA Type 4X
Applications
Power Generators
Submersible Pumps
Textile
Agricultural Equipment
Cement Cutting Equipment
Food Processing
Production Assembly Equipment
Spa and Hot Tubs
Vending Equipment
Circuit Guard® Hard Wired 30A GFCI - UL Type 4X Rated
Automatic Reset GFCI
Description
Voltage
Alarm
Manual Set
Automatic Set
Hard wired, manual set
and automatic set GFCIs.
120V AC
120V AC
240V AC
240V AC
120/240V AC
3Ø 250V AC
3Ø 120/208V AC
None
Audible
None
Audible
Audible
None
None
GFHW13005
GFHW13015
GFHW23005
GFHW23015
GFHW33015
GFHW530
GFHW430
GFHW13105
GFHW13115
GFHW23105
GFHW23115
GFHW33115
GFHW531
GFHW431
Note: All units above are stock items.
Specifications
Manual Reset GFCI
Electrical Ratings
Rated Voltage
120V AC, 240V AC and 120/240V, 3Ø 250V AC, 3Ø 120/208V AC.
Operating Voltage Range
85% to 110%.
Current
Up to 30A or device rating.
Frequency 60 Hz.
Trip Level
4-6 mA.
PhaseSingle.
Response Time
.025 sec. Max.
Dielectric Withstand
1500 VRMS across contact, 4000 VRMS between conductors and enclosure.
Surge Withstand
6000V impulse, 0.5 microseconds rise time 100kHz ringing frequency with
40% decay per cycle.
Let Go Line Voltage
60% of rated.
Grounded Neutral Detection
6 Ohms or less.
Power Up
Manual or automatic reset.
3.37"
(85.6)
4.80"
(121.9)
2.82"
(12.9)
Environmental Ratings
Housing Rating
Construction
Type
Operating Temperature
Leakage Current @ 93% Humidity
UL Type 4X.
Industrial grade design.
Class A GFCI.
-35°C to 66°C, -30°F to 150°F.
Zero.
.20 x 4
¾" N.P.T.
Dimensional Drawing
Features
Life (Endurance)
Grounded Neutral Protection
Power On Indicator
Power Off Indicator
Wiring Application
Switch Interface
Latching Mechanism
10,000 cycles (6000 with load and 4000 without load).
Open neutral protection Trips upon loss of neutral.
Trips if ground and neutral touch at load side.
Green light on.
Red blinking light plus optional audible alarm.
3 Wire Single Phase (Hot, Neutral and Ground),
4 Wire Single Phase (Line 1,Line 2, Neutral and Ground).
Double Insulated.
Electromagnetic.
2.64"
(67.1)
5.75"
(146.0)
Physical Specifications
Wire Leads
Unit Color
Label Color on Portable
and Hard Wired Units
Weight
#10 AWG, 24" long.
Gray with black cover.
Automatic reset: yellow background with black lettering.
Manual reset: black background with yellow lettering.
1.40 lbs.
Related Code
Confined Space Construction Sites
Commercial Garages
Fountains
Spas and Hot Tubs
Marinas
www.hubbell-wiring.com
24.00"
(609.6)
OSHA 29 CFR 1926.404 (b) (1) (ii)
OSHA 29 CFR 1926.405 (a) (2) (ii) (G)
NEC 590.6
NEC 511.12
NEC 680.5B
NEC 680.40
NEC 555.3
Side View
Dimensions in Inches (mm)
®
Wiring Device-Kellems
K-17
Ground Fault Products
Portable 30 Ampere GFCI - NEMA Type 4X
Applications
Pressure Washers
De-icing Equipment
Pipeline Heaters
Portable Electric Heaters
Material Dryers
Automotive Garages
Portable Power Tools
Submersible Pumps
Outdoor Signage
GFP1311
Circuit Guard® Portable 30A GFCI - UL Type 4X Rated
Description
Cord Length
Voltage
Manual Set
Automatic Set
Portable, manual set and
automatic set GFCIs.
2' (60.9 cm)
6' (182.9 cm)
25' (762.0 cm)
50' (1524.0 cm)
2' (60.9 cm)
25' (762.0 cm)
6' (182.9 cm)
6' (182.9 cm)
6' (182.9 cm)
120V AC
120V AC
120V AC
120V AC
240V AC
240V AC
120/240V AC
3Ø 250V AC
3Ø 120/208V AC
GFP1301
GFP1305
GFP1302
GFP1303
GFP2301
GFP2302
GFP3305
GFP5305
GFP4305
GFP1311
GFP1315
GFP1312
GFP1313
GFP2311
GFP2312
GFP3315
GFP5315
GFP4315
GFPIL30250LKM
3.37"
(85.6)
Note: All units above are stock items.
Circuit Guard® 30A GFCI In Line GFCI – Locking
4.80"
(121.9)
Description
Cord Length
Voltage
Manual Set
Automatic Set
L5-30 locking.
L6-30 locking.
2' (60.9 cm)
2' (60.9 cm)
120V AC
250V AC
GFPIL30125LKM
GFPIL30250LKM
GFPIL30125LKA
GFPIL30250LKA
Plug and Connector Selector Chart (partial listing)
The chart below is a list of possible Hubbell plug and connector body products that can be used with the Hubbell
Portable GFCIs.
Family
Dimensional Drawing
Style Insulgrip®
Straight Blade Insulgrip®Twist-Lock® ®
Watertight Safety-Shroud Twist-Lock® IEC Pin & Sleeve
Watertight Pin & Sleeve Insulgrip® Pin & Sleeve
Insulgrip® Pin & Sleeve Hubbellock®Hubbellock® Amps
Voltage 15
30
30
30
30
20
120V AC 240V AC 240V AC 240V AC 240V AC 120V AC Hubbell Catalog Number
HBL5266C & HBL5269C
HBL2621 & HBL2623
HBL2621SW & HBL2623SW
HBL330P6W & HBL330C6W
HBL330PS2W & HBL330CS2W
HBL23035B & HBL23032B
Specifications
Electrical Ratings
120V AC, 240V AC, 120/240V AC,
Rated Voltage
3Ø 250V AC, 3Ø 120/208V AC.
85% to 110%.
Operating Voltage Range
Current
Up to 30A or device rating.
Frequency 60 Hz.
Trip Level
4-6 mA.
Response Time
25 mS Max.
Dielectric Withstand
1500 VRMS across contact, 4000 VRMS
between conductors and enclosure.
Surge Withstand
6000V impulse, 0.5 microseconds rise time
100kHz ringing frequency with 40% decay
per cycle.
Let Go Line Voltage
60% of rated.
Power Up
Manual or Automatic reset.
Environmental Ratings
Housing Rating
UL Type 4X.
Construction
Industrial grade design.
Type
Meets UL943 Class A GFCI.
Operating Temperature
-35°C to 66°C, -30°F to 150°F.
Leakage Current @ 93% Humidity
Zero.
Dimensions in Inches (mm)
K-18
®
Features
Life (Endurance)
Open Neutral Protection
Grounded Neutral Protection
Power On Indicator
Power Off Indicator
Wiring Application
Switch interface
Latching Mechanism
Physical Specifications
Cord Type
Unit Color
Label Color on Portable and Hard Wired Units
Weight
10,000 cycles (6000 with load and 4000 without load).
Trips upon loss of neutral.
Trips if ground and neutral touch at load side.
Green light on.
Red blinking light plus optional audible alarm.
3 Wire Single Phase (Hot, Neutral and Ground).
4 Wire Single Phase (Line 1, Line 2, Neutral and Ground).
Double Insulated.
Electromagnetic.
2-50', 10/3 SJGOOW. 100', 8/3 SEOW.
Gray with black cover.
Automatic reset: Yellow background with black lettering. Manual reset: Black background
with yellow lettering.
2 ft. 1.8 lbs., 6 ft. 2.7 lbs., 25 ft. 6.8 lbs.,
50 ft. 12.4 lbs.,100 ft. 23.3 lbs.
Related Code
Confined Space Construction Sites
Commercial Garages
Outdoor Signs
Spas and Hot Tubs
Boat Yards
Wiring Device-Kellems
OSHA 29 CFR 1926.404 (b) (1) (ii)
OSHA 29 CFR 1926.405 (a) (2) (ii) (G)
NEC 590.6
NEC 511.12
NEC 600.10
NEC 680.40
NEC 555.3
www.hubbell-wiring.com
Download