OSEM Preliminary Design Review 12th July 2005 Interface Control Document (ICD): Suspension, UK Scope (SUS/UK) – Suspension, US Scope (SUS/US) E050160-01 (draft2) Document Highlights S. Aston / D. Hoyland LIGO-G050xxx-00-K OSEM Preliminary Design Review 12th July 2005 OSEM Local Coordinate System » x & y axes on the plane of the coil former front face » (Sensing) z-axis, is axial through the centre of coil former cylinder – Origin at the centre of the front face of coil former z see section 1.1.1.1, figure 3 OSEM Mass Properties » Mass given is that measured for the actual prototype OSEM device – Need to specify a target OSEM mass, (any requirement on upper limit?) » Centre of Mass figures taken from Solidworks model (using available z-axis OSEM adjustment) z LIGO-G050xxx-00-K see section 1.1.1.1.1 AdLIGO 2 OSEM Preliminary Design Review 12th July 2005 OSEM Envelope » ‘Slimmed Down’ version of OSEM clamp – Now uses the same (external) dimensions as the Hybrid OSEM clamp z see section 1.1.1.1.2, figure 4 OSEM Adjustment (to summarize) » x-y axes have ± 0.3 mm (via oversized tapped mounting holes) » (Sensing) z-axis, has ± 5.6 mm (via OSEM adjustment assembly) – Need to specify a target OSEM mass, (any requirement on upper limit?) » Centre of Mass figures taken from model (using OSEM adjustment z LIGO-G050xxx-00-K see section 1.1.1.1.1 AdLIGO 3 OSEM Preliminary Design Review 12th July 2005 OSEM Flag Dimensions » Length driven by sensor and actuator separation – For reference T050111-00-K - OSEM Preliminary Design Document » Dimensions for prototype design are as follows:– ∅ 3 mm cylindrical flag, extended section ≈ 30 mm » Coil Former Key Dimensions – Coil former (minimum) ID of flag port = 4.78 mm – (Coil former (maximum) ID of magnet port = 12.7 mm) LIGO-G050xxx-00-K AdLIGO 4 OSEM Preliminary Design Review 12th July 2005 Power Interface » Local Regulation on low rails and TBC high voltage rails (pending further investigation, » Voltages at the Subrack input specified ±1V Cabling – Rack to satellite box and satellite box to vac » Should now be compatible and consistent with vac cables for LASTI Input/ Output Ranges » Common understanding: 0V/10V to 10V/0V = +/-10V = 20V pk-pk LIGO-G050xxx-00-K AdLIGO 5 OSEM Preliminary Design Review 12th July 2005 Cable Driving » Assuming 100pF/m core to core and core to ground for testing Noise » Sensor 8uV/rtHz at 10Hz? » Actuator (not penultimate) 100pA/rtHz with input noise 1uV/rtHz » Actuator (penultimate) 30pA/rtHz with input noise 1uV/rtHz Coil Drive Output Impedance » Non penultimate – 100R » Penultimate – 1KR Power Dissipation » Convection Cooling LIGO-G050xxx-00-K AdLIGO 6